Electrochemical Instrumentation
Total Page:16
File Type:pdf, Size:1020Kb
Electrochemical Instrumentation ______________________________________________________________________________ CH Instruments 1 Overview CH Instruments was established in 1994. Our first instrument series, the Model 600 series electrochemical analyzer/workstation, was introduced at the end of 1994. Since then, new products have been added to provide a full line of electrochemical instrumentation: Model 400A Series Time-Resolved Electrochemical Quartz Crystal Microbalance (EQCM): for electro-deposition, adsorption, and chemical and biological sensor studies. Model 600D Series Potentiostat/Galvanostat: for general purpose electrochemical measurements, such as kinetic measurements, electroanalysis, fundamental research, corrosion, and battery studies. Model 700D Series Bipotentiostat: for rotating ring-disk electrodes (RRDE) and other cases where dual channel measurements are essential. Model 800C Series Electrochemical Detector: for either single or dual channel electrochemical detection of flow cell, capillary electrophoresis and liquid chromatography, for chemical and biological sensors, and conventional electroanalysis. Model 920C Scanning Electrochemical Microscope (SECM): for electrode surface, corrosion, biological samples, solid dissolution, liquid/liquid interfaces and membranes studies. Model 1000A Series Multi-potentiostat: 8-channel potentiostat for array electrode characterization and sensor studies. It can be used for eight independent cells or for eight working electrodes in a same solution. Model 1100A Power Potentiostat/Galvanostat: for applications involving higher current and compliance voltage. Model 1200A Handheld Potentiostat/Bipotentiostat: for electroanalysis, sensor studies, and field applications. Model 1550A Pico Liter Solution Dispenser: for making high density and high accuracy solution arrays. All models are controlled by an external PC under the Windows 95/98/NT/Me/2000/XP environment. The instruments are easy to install and use. No plug-in card or other hardware is required on the PC side. These instruments provide a rich repertoire of electrochemical techniques. Most well-established electrochemical techniques can be readily employed, including potential sweep, step, pulse, alternating current, stripping, and various other techniques. For each instrument series, we provide various models to suit different needs and budgets. Our instruments offer superior performance at competitive prices, and are ideal for both research and teaching purposes. 2 Model 400A Time-Resolved Electrochemical Quartz Crystal Microbalance The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b shows an edge view of a QCM crystal that is undergoing the shear distortion from the oscillation. The central portions of the top and bottom sides of the crystal are coated with a typically disk-shaped thin film of gold or other metals. The mass sensitivity of the QCM originates from the relationship between the oscillation frequency on the total mass of the crystal and the adlayers of materials residing at the metal-coated crystals, given by the Sauerbrey equation below: 2 ∆f = -2f0 ∆m / [A sqrt(µρ)] where f0 is the resonant frequency of the fundamental mode of the crystal, A is the area of the gold disk coated onto the crystal, ρ is the density of the crystal (= 2.684 g/cm3), and µ is the shear modulus of quartz (= 2.947 x 1011 g/cm.s2). Using a crystal with a 7.995-MHz fundamental frequency (as used in our measurements) as an example, a net change of 1 Hz corresponds to 1.34 ng of materials adsorbed or desorbed onto the crystal surface of an area of 0.196 cm2. QCM and the combination of QCM with electrochemistry (EQCM) have been widely employed for the determination of metals deposited onto the crystal, studies of ion-transport processes in polymer films, biosensor development, and investigations of the kinetics of adsorption/desorption of adsorbate molecules. In EQCM experiments, the measurements of the various electrochemical parameters, such as potential, current and charge at the working electrode, and the acquisition of the corresponding frequency change, can be conducted simultaneously with the experimental setup shown in Figure 1a. For any model in the CHI400A series, the application of a specific potential waveform (e.g., triangular potential waveform for cyclic voltammetric experiments), as well as subsequent current measurements and the frequency counting, was carried out with a potentiostat/frequency counter, in turn controlled by a computer. Figure 1. Schematic representation of a typical EQCM instrument. (a) The quartz crystal has a fundamental frequency of 7.995 MHz and is coated with thin gold films on both sides. The gold disk deposited on the top side of the crystal is in contact with the electrolyte solution and used as the working electrode. The top view of the gold- coated crystal is also shown. (b) Edge view of QCM crystal showing shear deformation. The disk thickness and shear deformation have been exaggerated for clarity. The CHI400A series contains a quartz crystal oscillator, frequency counter, fast digital function generator, high-resolution and high-speed data acquisition circuitry, potentiostat, and a galvanostat (Model 440A only). The 3 QCM is integrated with potentiostat and galvanostat, making the EQCM study simple and convenient. Instead of measuring the frequency directly, the CHI400A series uses time-resolved mode. The frequency signal of the QCM is subtracted from a standard reference frequency. The difference is then measured by a reciprocal technique, which greatly reduces the time needed to sample the QCM signal and gives much better time resolution of the QCM signal. With the direct counting method, a 1 Hz QCM resolution requires 1 second of sampling time, and a 0.1 Hz resolution requires 10 seconds of sampling time. The time-resolved mode allows the QCM signal to be measured in milliseconds with much better resolution. The potential control range of the instrument is ±10 V and the current range is ±250 mA. Besides QCM and EQCM measurements, the instrument can also be used for general-purpose electrochemical applications, which are integrated. The instrument is very sensitive and very fast, capable of measuring current down to the picoampere level. The scan rate in cyclic voltammetry can be up to 100 V/s with a 0.1 mV potential increment or 2000 V/s with a 2 mV potential increment. Figure 2 shows the voltammogram of underpotential and bulk depositions of Pb from a 0.1 M HClO4 solution containing 1 mM Pb2+, and the corresponding frequency changes have been plotted as a function of the applied potential. In Figure 2a, the cathodic peaks at –0.28 V and at ca. –0.59 V have been assigned to the underpotential deposition of monolayer Pb and the bulk deposition of multlayers of Pb, respectively, whereas the anodic peaks at –0.41 V and at –0.28 V are attributable to the stripping of the deposited Pb. The frequency-potential diagram (Figure 2b) displays the frequency decrease due to the deposition of monolayer Pb (about 25 Hz or 33.5 ng between –0.28 V and –0.59 V) and the more drastic frequency decrease arising from bulk Pb deposition (a net change of 425 Hz or 573.8 ng at ca. –0.5 V). Figure 2. Voltammogram and QCM data of Pb underpotential deposition. Scan rate = 0.05 V/s. 4 Figure 3 depicts the voltammogram of the oxidation of pyrrole to form polypyrrole film at the gold-coated crystal and the corresponding frequency change. Five scan segments between the lower limit of –1.0 V and the upper limit of 1.0 V were conducted in this experiment. As clearly shown in Figure 3a, pyrrole monomer can be oxidized to its radical at ca. 0.65 V. When this occurred, a thin polypyrrole film was formed, resulting in a decrease of the fundamental frequency of the quartz crystal (Figure 3b). During the first potential cycle, the net frequency change was found to be 1150 Hz. The frequency ceased to change, as the potential became insufficiently positive for the synthesis of polypyrrole film. The subsequent potential cycles displayed in Figure 3 demonstrate the continuous growth of polypyrrole film and the further frequency decrease or mass increase at the crystal. A fast scan rate (0.1 V/s) was employed. Figure 3. Voltammogram and QCM data of oxidation of pyrrole to form polypyrrole film. Scan rate 0.1 V/s. The instrument can also be used for regular QCM. Figure 4 shows the QCM data of flow cell detection. The total frequency change is less than 8 Hz. The long term drift and noise levels are extremely low. The model 400A series is our upgrade to the model 400 series. The redesigned instrument contains a new processor (about 50 times faster than the 400) and FLASH memory (allowing instrument updates to be distributed by e-mail instead of the shipment of an EPROM chip). 5 Figure 4. A typical flow injection-QCM experiment. As soon as the sample is injected, the QCM starts recording the frequency change (t = 0). The pump is stopped at 460 s (where a small glitch on the curve can be seen). The reaction is completed about 40 min after sample injection. The total monitoring time is over 1 hr. A net change of 8 Hz is monitored. After 40 min or so, the frequency becomes very stable again (for at least more than 20 min, the frequency drift is much less than 1 Hz). The 400A series has a serial port (default) and a USB for data communication with the PC. You can select either serial port or USB (but not both) by changing the jumper setting on the board. A 16-bit highly stable bias circuitry is added for current or potential bias.