190S – a N D 2 – C A16 C – TE Eco and Compact Combination Starters
Total Page:16
File Type:pdf, Size:1020Kb
Bulletin 190/191 Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all 0 combinations will produce a valid catalog number. 190S – A N D 2 – C A16 C – TE abcdefghi 1 a d, continued h Bulletin Number DC Coil Voltage — Bul. 190S only Circuit Breaker Aux. and Trip Contacts for Starter Type Code Description 140M Code Description ZR 6...12V DC Bottom Front 2 190S DOL Starter with MPCB ZQ 12V DC Code Description 191S Rev Starter with MPCB ZJ 24V DC C 1 N.O. + 1 NC Aux. Contact D 2 N.O. Aux. Contact b DJ 24V DC with Diode EJ 24V DC electronic1 R 1 N.O. (SC+OL) + 1 NC Aux. Contact Contactor Size ZW 36V DC S 1 N.O. (SC+OL) + 1 N.O. Aux. Contact 3 Code Description ZY 48V DC A 100-C09 i ZZ 60V DC B 100-C12 Modifications, Accessories ZB 64V DC C 100-C16 Circuit Breaker Accessories ZG 72V DC D 100-C23 Code Description 4 ZE 80V DC E 100-C30 TE Spacer Module ZD 110V DC F 100-C37 KN Lockable Twist Knob, Black ZP 115V DC G 100-C43 KY Lockable Twist Knob, Red/Yellow ZS 125V DC Additional CB Auxiliaries (Side Mount) 5 c ZA 220V DC Code Description Style ZF 230V DC A02 2 N.C. Code Description ZT 250V DC A20 2 N.O. 1 Open Style — Screw mount (4), 35 mm Also available for Bulletin 191S A11 1 N.O. + 1 N.C. N top hat rail mount (2) or 75 mm top hat Additional CB Trip Contacts (Side Mount) 6 rail mount (1) e Code Description d Contactor Aux. Contacts R00 1 N.O. Thermal-Mag + 1 N.O. Mag Only AC Coil Voltage Code Description R01 1 N.O. Thermal-Mag + 1 N.C. Mag Only Code Description 2 1 N.O. (190S only) R10 1 N.C. Thermal-Mag + 1 N.O. Mag Only 1 N.O. + 1 N.C. (Bul. 191S and 190S, 7 Q 12V AC, 60 Hz 3 R11 1 N.C. Thermal-Mag + 1 N.C. Mag Only contactor sizes E…G only) R 12V AC, 50 Hz M11 1 N.O. Mag Only + 1 N.C. Mag Only J 24V AC, 60 Hz f Coil Accessories K 24V AC, 50 Hz Circuit Breaker Frame Size Code Description 8 KJ 24V AC, 50/60 Hz Code Description JE Electronic Interface(s) V 32V AC, 50 Hz /36V AC, 60 Hz C C Frame D Surge Suppressor Diode W 36V AC, 50 Hz D D Frame R Surge Suppressor RC X 42V AC, 50 Hz /48V AC, 60 Hz F F Frame V Surge Suppressor Varistor Y 48V AC, 50 Hz g Additional Contactor Auxiliaries (Side Mount) 9 KY 48V AC, 50/60 Hz Code Description Circuit Breaker Current Range KP 100V AC, 50 Hz /100...110V AC, 60 Hz S01 1 N.C. Code Description D 110V AC, 50 Hz /120V AC, 60 Hz S10 1 N.O. A16 0.1...0.16 A KD 100V AC, 50/60 Hz S11 1 N.O. + 1 N.C. A25 0.16...0.25 A P 120V AC, 50 Hz S20 2 N.O. 10 A40 0.25...0.4 A KL 200...230V AC, 50/60 Hz Additional Contactor Auxiliaries (Front Mount) A63 0.4...0.63 A H 208V AC, 60 Hz Code Description B10 0.63...1.0 A L 208...240V AC, 60 Hz F11 1 N.O. + 1 N.C. B16 1.0...1.6 A A 220V AC, 50 Hz /240V AC, 60 Hz F20 2 N.O. B25 1.6...2.5 A 11 F 220...230V AC, 50 Hz F22 2 N.O. + 2 N.C. KF 230V AC, 50/60 Hz B40 2.5...4.0 A VA 230...240V AC, 50 Hz B63 4.0...6.3 A T 240V AC, 50 Hz /277V AC, 60 Hz C10 6.3...10 A 12 E 380V AC, 60 Hz C16 10...16 A N 380...400V AC, 50 Hz /440V AC, 60 Hz C20 16...20 A KN 400V AC, 50/60 Hz C25 20...25 A G 400...415V AC, 50 Hz C32 25...32 A B 440V AC, 50 Hz /480V AC, 60 Hz C45 32...45 A 13 M 500V AC, 50 Hz C 550V AC, 50 Hz /600V AC, 60 Hz www.ab.com/catalogs Preferred availability cat. nos. are bold. 2-356 Publication A117-CA001A-EN-P Bulletin 190S/191S Compact Combination Starters Product Selection Bulletin 190S Direct On-Line Compact Starters 190S Compact Starter using Bulletin 140M Motor Protection Circuit Breaker and Bulletin 0 100-C Contactor I > Short-Circuit Coordination Type "1" and "2" according to IEC 60947-4-1 Complete unit, ready for connection with internal wiring Accessories: Bulletin 140M Circuit Breakers and 100-C Contactors 1 Removable cover IEC and cULus Certified M Auxiliary Contacts Wired to Terminal Block at Bottom of Starter Assembly 3 ~ Mounting Versions: - Screw Fixing 2 - Snap Fixing on (1) or (2) 35 mm top hat rails - Snap Fixing on (1) 75 mm top hat rail Group Motor, Type E and Type F Combination Motor Controllers (UL/CSA) 3 The 190S/191S motor controllers can be used in a variety of applications. These starters can be used in a group motor application or as a stand alone product without any additional short-circuit protection in the motor branch circuits. Most of the 140M-C/D motor protection circuit breakers used in the 190S/191S starters are UL Listed as a manual Type E self-protected combination motor controller. Although there are many tests involved, one of the critical tests that the self-protected combination motor 4 controller must pass is to perform 6000 electrical ops. and an additional 4000 mechanical ops. after a short circuit. By definition, a Type F combination motor controller consists of a Type E manual self-protected combination motor controller and a magnetic or solid-state motor controller (e.g., a 100-C contactor or an SMC). As with a manual Type E self-protected combination motor controller, 5 additional short-circuit protection is not required for the individual motor circuits. The combination of a 140M manual self-protected combination motor controller and 100-C contactor can be listed as a Type E self-protected combination motor controller. In this case, the 140M and 100-C must pass the additional 6000 electrical and 4000 mechanical operational 6 test. In some cases, this may require oversizing the 140M motor protection circuit breaker or the 100-C contactor to achieve weld-free performance and meet the additional life requirements. NOTE: Verify that the motor protection circuit breaker can be set to the rated motor current. 7 8 9 10 11 12 13 www.ab.com/catalogs Preferred availability cat. nos. are bold. 2-364 Publication A117-CA001A-EN-P Bulletin 190S/191S Compact Combination Starters Product Selection & Coordination Ratings UL/CSA in Group Motor Installations UL/CSA Hp Ratings (60 Hz) Max. Short-Circuit Current [kA] Motor Max. Fuse or 0 Current Hp Ratings as a UL508 Motor Controller in Group Motor Circuit Reversing Starter ♣ Adjustment Installations Breaker per Type 1 Coordination Type 2 Coordination DOL Starter (AC coils only) Range [A] 200V 230V 460V 575V NEC [A] 480V 600V 480V 600V Cat. No. Cat. No. C-Frame with Bulletin 100-C/104-C Contactors 0.10…0.16————45065476547190S-AN⊗2-CA16C 191S-AN⊗3-CA16C 0.16…0.25————45065476547190S-AN⊗2-CA25C 191S-AN⊗3-CA25C 1 0.25…0.40————45065476547190S-AN⊗2-CA40C 191S-AN⊗3-CA40C 0.40…0.63————45065476547190S-AN⊗2-CA63C 191S-AN⊗3-CA63C 0.63…1.00 — — 1/2 3/4 450 65 47 65 47 190S-AN⊗2-CB10C 191S-AN⊗3-CB10C 1.00…1.60 — — 1/2…1 3/4...1 450 65 47 65 47 190S-AN⊗2-CB16C 191S-AN⊗3-CB16C 1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 450 65 30 65 10 190S-AN⊗2-CB25C 191S-AN⊗3-CB25C 2 2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 450 65 30 50 — 190S-AN⊗2-CB40C 191S-AN⊗3-CB40C 4.00…6.30 1...1-1/2 1…2 3...5 5 450 65 30 50 — 190S-AN⊗2-CB63C 191S-AN⊗3-CB63C 6.30…9.00 1-1/2…2 2 5 7-1/2 450 65 30 50 — 190S-AN⊗2-CC10C 191S-AN⊗3-CC10C 6.30…10.0 1-1/2…3 2...3 5...7-1/2 7-1/2...10 450 65 30 50 — 190S-BN⊗2-CC10C 191S-BN⊗3-CC10C 10.0…12.0 3 3 7-1/2 10 450 30 30 — — 190S-BN⊗2-CC16C 191S-BN⊗3-CC16C 10.0…16.0 3...5 5 7-1/2…10 10 450 30 30 — — 190S-CN⊗2-CC16C 191S-CN⊗3-CC16C 3 10.0…16.0 3...5 5 7-1/2…10 10...15 450 30 30 — — 190S-DN⊗2-CC16C 191S-DN⊗3-CC16C 14.5…20.0 5 5...7-1/2 15 15 450 30 30 — — 190S-DN⊗2-CC20C 191S-DN⊗3-CC20C 18.0…23.0 5 7-1/2 15 15 450 30 30 — — 190S-DN⊗2-CC25C 191S-DN⊗3-CC25C D-Frame with Bulletin 100-C/104-C Contactors 1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 450 65 30 65 10 190S-AN⊗2-DB25C 191S-AN⊗3-DB25C 4 1.60…2.50 1/2 1/2...3/4 3/4…1-1/2 1…2 450 65 30 65 30 190S-DN⊗2-DB25C 191S-DN⊗3-DB25C 2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 450 65 30 65 — 190S-AN⊗2-DB40C 191S-AN⊗3-DB40C 2.50…4.00 1/2…1 3/4...1 1-1/2…3 2…3 450 65 30 65 30 190S-DN⊗2-DB40C 191S-DN⊗3-DB40C 4.00…6.30 1…1-1/2 1…2 3…5 5 450 65 30 65 — 190S-AN⊗2-DB63C 191S-AN⊗3-DB63C 6.30…9.00 1-1/2…2 2 5 7-1/2 450 65 30 65 — 190S-AN⊗2-DC10C 191S-AN⊗3-DC10C 5 6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 450 65 30 65 — 190S-BN⊗2-DC10C 191S-BN⊗3-DC10C 6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 450 65 30 65 — 190S-CN⊗2-DC10C 191S-CN⊗3-DC10C 10.0…12.0 3 3 7-1/2 10 450 65 30 65 — 190S-BN⊗2-DC16C 191S-BN⊗3-DC16C 10.0…16.0 3…5 5 7-1/2…10 10 450 65 30 65 — 190S-CN⊗2-DC16C 191S-CN⊗3-DC16C 10.0…16.0 3…5 5 7-1/2…10 10…15 450 65 30 65 — 190S-DN⊗2-DC16C 191S-DN⊗3-DC16C 6 14.5…20.0 5 5...7-1/2 15 15 450 65 30 65 — 190S-DN⊗2-DC20C 191S-DN⊗3-DC20C 18.0…23.0 5 7-1/2 15 15 450 65 30 65 — 190S-DN⊗2-DC25C 191S-DN⊗3-DC25C F-Frame with Bulletin 100-C/104-C Contactors 6.30…10.0 1-1/2…3 2...3 5…7-1/2 7-1/2…10 600 65 30 65 30 190S-EN⊗3-FC10C — 10.0…16.0 3…5 5 7-1/2…10 10…15 600 65 30 65 30 190S-EN⊗3-FC16C — 14.5…20.0 5 5…7-1/2 15 15…20 600 65 30 65 30 190S-EN⊗3-FC20C — 7 18.0…25.0 7-1/2 7-1/2...10 15...20 20 600 65 30 65 30 190S-EN⊗3-FC25C — 18.0…25.0 7-1/2 7-1/2...10 15...20 20...25 600 65 30 65 30 190S-GN⊗3-FC25C — 23.0…30.0 7-1/2 10 20 25 600 65 30 65 30 190S-EN⊗3-FC32C — 23.0…32.0 7-1/2...10 10 20...25 30 600 65 30 65 30 190S-FN⊗3-FC32C — 23.0…32.0 7-1/2...10 10 20...25 30 600 65 30 65 30 190S-GN⊗3-FC32C — 8 32.0…37.0 10 10 25 30 600 65 18 65 10 190S-FN⊗3-FC45C — 32.0…43.0 10 15 30 30 600 65 18 65 10 190S-GN⊗3-FC45C — ♣ Hp ratings shown in the table are for reference.