Temperature Measurement Solutions

Total Page:16

File Type:pdf, Size:1020Kb

Temperature Measurement Solutions Temperature Measurement Solutions Dial Indicating Electronic Industrial RTDs Thermowells Accessories t NOSHOK, we pride ourselves on being innovators in the industry by Acontinually offering the latest technology and measurement solutions, and providing the best customer support in the marketplace. Established in 1967, NOSHOK was one of the first companies to offer liquid filled pressure gauges. We also took a bold step by backing our quality gauges with an extended 3-year warranty. That unwavering standard of quality has endured for over 50 years, and as we have expanded our product offering we continue to provide industry-leading warranties. NOSHOK also leads the industry as one of the first companies to offer corrosion-resistant zinc nickel plating standard on our carbon steel valves. We have the capacity to put together special requirements which are so often hard to find. If you do not find what you need in this catalog, chances are we can still put a solution together. NOSHOK is committed to providing excellence on every level. Thank you for choosing NOSHOK products. Jeff N. Scott President NOSHOK Corporate Headquarters Your Single Source Instrumentation Company NOSHOK is a member and actively supports: NOSHOK is an ISO 9001:2015 registered company. WARRANTY INFORMATION NOSHOK’s Eight Year Warranty applies to our 3" and 5" 300 Series Bimetal Thermometers. Our Three Year Warranty applies to our 800 Series Platinum Resistance Temperature Transmitters, 810 Series Compact OEM Temperature Transmitters, 820/821 and 822/823 Series Digital Temperature Indicators, 850 Series Electronic Indicating Temperature Switch/Transmitters, 900/915 Series Probe-Type Industrial RTDs, 910 Series Probe-Type Industrial RTDs with Process Connection and 920 Series RTD Transmitter. Our One Year Warranty applies to our 100, 150, 300 (2") and 350 Series Bimetal Thermometers, Vapor Actuated Remote Thermometers and Thermowells. NOSHOK guarantees all products to be free from defects in material and workmanship, to remain within catalogued accuracy specifications, and to operate within the catalogued performance specifications. These products must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc.’s equipment and personnel or a certified test facility specializing in this type of evaluation. TABLE OF CONTENTS DIAL INDICATING THERMOMETERS Bimetal, Industrial Type: 100 SERIES ................................................................................................................................................................................................................4-7 Bimetal, Testing and General Purpose: 150 SERIES .............................................................................................................................................................................................................. 8-11 Bimetal, Industrial Type with External Reset: 300 SERIES ............................................................................................................................................................................................................12-15 Bimetal, Testing and General Purpose with External Reset: 350 SERIES ............................................................................................................................................................................................................16-19 Vapor Actuated Remote: 300/400/600/700/900 SERIES ...............................................................................................................................................................................20--27 DIAL INDICATING THERMOMETER OPTIONS Maximum Indicating Pointer, Silicone Filled, Stem Types, Connections, Special Dials, Lenses, Certified Calibration ...........................................28-29 ELECTRONIC TEMPERATURE MEASUREMENT Platinum Resistance Temperature Transmitter: 800 SERIES ............................................................................................................................................................................................................30-31 Compact OEM Temperature Transmitter: 810 SERIES ............................................................................................................................................................................................................32-33 Digital Temperature Indicator: 820/821 SERIES .....................................................................................................................................................................................................34-35 Digital Temperature Indicator, Battery Powered 822/823 SERIES .....................................................................................................................................................................................................36-37 Electronic Indicating Temperature Transmitter/Switch: 850 SERIES ............................................................................................................................................................................................................38-39 INDUSTRIAL RESISTANCE TEMPERATURE DEVICES (RTD) Industrial RTD, Probe Type: 900 SERIES ............................................................................................................................................................................................................40-41 Industrial RTD, Probe Type with Connection Head: 910/915 SERIES .....................................................................................................................................................................................................42-43 RTD Transmitter: 920 SERIES .................................................................................................................................................................................................................44 RTD ACCESSORIES Connection Heads, Terminal Blocks .............................................................................................................................................................................45 THERMOWELLS Thermowells: 50/75/100 SERIES ..................................................................................................................................................................................................46-48 Reference Information ..........................................................................................................................................................................................49-53 In keeping with and for purpose of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. 3 Dial Indicating Thermometers Bimetal, Industrial Type 100 SERIES • Heavy-duty, industrial thermometer featuring a weather-resistant, tamper-proof case • Single °F, single °C, and dual scale options available • Accuracy: ±1% full scale, Grade A, ASME B40.3 • 1-3/4", 2", 3" and 5" sizes - center back connection only • 304 Stainless Steel case and bezel • Standard stem lengths 2-1/2" through 42" • Highly sensitive bimetallic helix coil is heat-treated for stress relief, and silicone- coated to minimize pointer vibration and maximize heat transfer and response time • 360° groove around stem is a visual reference to show minimum immersion point • Made in the U.S.A. SERIES SPECIFICATIONS Case & bezel All 100 Series 304 Stainless Steel; 316 Stainless Steel optional Lens All 100 Series Instrument glass Pointer All 100 Series Aluminum, black finish Stem diameter 18-110 .150" (3.81 mm) 20-110, 30-110, 50-110 .250" (6.35 mm) Accuracy All 100 Series ±1% full scale, Grade A, ASME B40.3 Dial All 100 Series Anodized Aluminum with large black numbers and graduations APPLICATIONS Process connection 18-110 1/4" NPT, 1/8" and 3/8" NPT optional Used in almost every area of manufacturing, 20-110 1/4" NPT especially suited for applications in the 30-110, 50-110 1/2" NPT following areas: Wetted parts All 100 Series 304 Stainless Steel; 316 Stainless Steel optional Hermetic seal All 100 Series Per ASME B40.3 dustproof and leakproof Industrial process Bimetal coil All 100 Series Silicone coated helix coil on ranges below Petrochemical 500 °F for vibration dampening, maximum Food & beverage processing heat transfer and response time Commercial Over temperature All 100 Series Up to 250 °F 100%; 250 °F to 550 °F 50%; limits 550 °F to 1,000 °F continuous use up to Wastewater 800 °F; intermittent use over 800 °F WARNING: This product can expose you to chemicals including Chromium (VI) and Nickel, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Thermowells are recommended for pressure, corrosive fluids and high velocity applications, see pages 46-48. 4 ORDERING 100 SERIES INFORMATION DIMENSIONS ORDERING INFORMATION DIAL SIZES 18 1-3/4" † † 30 3" 20 2" 50 5" CASE TYPES 110 Back connection STEM LENGTHS 025 2-1/2" 090 9" 240 24" Available up to 120" 040 4" 120 12" 300 30" 060 6" 150 15" 360 36" 080 8" † 180 18" 420 42" TEMPERATURE -100/100 F/C -100 °F/°C to 100 °F/°C 0/250 F/C 0 °F/°C to 250 °F/°C 50/500 F/C 50 °F/°C to 500 °F/°C RANGES -40/160 F/C -40 °F/°C to 160 °F/°C 20/240 F/C 20 °F/°C to 240 °F/°C 150/750 F/C 150 °F/°C to 750 °F/°C Dual Scale °F/ °C 0/140 F/C
Recommended publications
  • The Kelvin and Temperature Measurements
    Volume 106, Number 1, January–February 2001 Journal of Research of the National Institute of Standards and Technology [J. Res. Natl. Inst. Stand. Technol. 106, 105–149 (2001)] The Kelvin and Temperature Measurements Volume 106 Number 1 January–February 2001 B. W. Mangum, G. T. Furukawa, The International Temperature Scale of are available to the thermometry commu- K. G. Kreider, C. W. Meyer, D. C. 1990 (ITS-90) is defined from 0.65 K nity are described. Part II of the paper Ripple, G. F. Strouse, W. L. Tew, upwards to the highest temperature measur- describes the realization of temperature able by spectral radiation thermometry, above 1234.93 K for which the ITS-90 is M. R. Moldover, B. Carol Johnson, the radiation thermometry being based on defined in terms of the calibration of spec- H. W. Yoon, C. E. Gibson, and the Planck radiation law. When it was troradiometers using reference blackbody R. D. Saunders developed, the ITS-90 represented thermo- sources that are at the temperature of the dynamic temperatures as closely as pos- equilibrium liquid-solid phase transition National Institute of Standards and sible. Part I of this paper describes the real- of pure silver, gold, or copper. The realiza- Technology, ization of contact thermometry up to tion of temperature from absolute spec- 1234.93 K, the temperature range in which tral or total radiometry over the tempera- Gaithersburg, MD 20899-0001 the ITS-90 is defined in terms of calibra- ture range from about 60 K to 3000 K is [email protected] tion of thermometers at 15 fixed points and also described.
    [Show full text]
  • What Is Temperature
    City Research Online City, University of London Institutional Repository Citation: Kyriacou, P. A. (2010). Temperature sensor technology. In: Jones, D. P. (Ed.), Biomedical Sensors. (pp. 1-38). New York: Momentum Press. ISBN 9781606500569 This is the accepted version of the paper. This version of the publication may differ from the final published version. Permanent repository link: https://openaccess.city.ac.uk/id/eprint/3539/ Link to published version: Copyright: City Research Online aims to make research outputs of City, University of London available to a wider audience. Copyright and Moral Rights remain with the author(s) and/or copyright holders. URLs from City Research Online may be freely distributed and linked to. Reuse: Copies of full items can be used for personal research or study, educational, or not-for-profit purposes without prior permission or charge. Provided that the authors, title and full bibliographic details are credited, a hyperlink and/or URL is given for the original metadata page and the content is not changed in any way. City Research Online: http://openaccess.city.ac.uk/ [email protected] Biomedical Sensors: Temperature Sensor Technology P A Kyriacou, PhD Reader in Biomedical Engineering School of Engineering and Mathematical Sciences City University, London EC1V 0HB “...the clinical thermometer ranks in importance with the stethoscope. A doctor without his thermometer is like a sailor without his compass” Family Physician, 1882 Celsius thermometer (attached to a barometer) made by J.G. Hasselström, Stockholm, late 18th century Page 1 of 39 1. Introduction Human body temperature is of vital importance to the well being of the person and therefore it is routinely monitored to indicate the state of the person’s health.
    [Show full text]
  • Thermometry (Temperature Measurement)
    THERMOMETRY Thermometry ................................................................................................................................................. 1 Applications .............................................................................................................................................. 2 Temperature metrology ............................................................................................................................. 2 The primary standard: the TPW-cell ..................................................................................................... 5 Temperature and the ITS-90 ..................................................................................................................... 6 The Celsius scale ................................................................................................................................... 6 Thermometers and thermal baths .......................................................................................................... 7 Metrological properties ............................................................................................................................. 7 Types of thermometers.............................................................................................................................. 9 Liquid-in-glass ...................................................................................................................................... 9 Thermocouple ....................................................................................................................................
    [Show full text]
  • TEMPERATURE © 2019, 2008, 2004, 1990 by David A
    TEMPERATURE © 2019, 2008, 2004, 1990 by David A. Katz. All rights reserved. A BRIEF HISTORY OF TEMPERATURE MEASUREMENT Ancient people were physically aware of hot and cold and probably related temperature by the size of the fire needed, and how close to sit, to keep warm. An Australian tribe, still primitive, uses dogs instead of blankets to keep warm, thus, they can relate temperature by the dog. (See Figure 1.) A moderately cool night may require two dogs to keep warm, thus it is a two-dog night. An icy night would be a six-dog night. Early people were, at first, fire tenders, maintaining fires originally Figure 1. Australian started by natural causes. Later, they learned how to make fire and aborginies use dogs became fire makers. Eventually, they became fire managers as they to keep warm. learned to work with fire to gain the heat needed to boil water, cook meat, fire pottery (500°F or 257°C), work with copper, tin, bronze (an alloy of copper and tin) and iron, and to make glass. (See Figure 2) Although they had no quantitative measuring devices to determine how hot a fire was, they developed recipes for building different types of fires and probably used a physical indicator, such as some mineral or metal melting, to indicate the correct Figure 2. Early people temperature for a particular process. used fire to cook food and later to work with The ancient Greeks knew that air expanded when heated and metals. applied the principle mechanically, but they developed no means of measuring temperature or amount of heat needed and devised no measuring instruments.
    [Show full text]
  • The Science Behind Meaningful Temperature Measurement, Part 1: Introduction
    Calibrating Thermometers: The Science Behind Meaningful Temperature Measurement, Part 1: Introduction By Maria Knake, Laboratory Assessment Program Manager Posted: May 2012 A Promise is a Promise I've said it myself: without calibration, we have no confidence in the measurements that we take. And if a measurement isn’t meaningful, why even bother? Nevertheless, if you’ve read my previous articles, "The Anatomy of a Liquid-in-Glass Thermometer" and "Let’s Get Digital," you know that, up to this point, I have (intentionally) avoided the subject of thermometer calibration. So, if calibration is such an important subject, why have I been avoiding it for so long? The answer is simple: I’ve been procrastinating. As I promised at the end of my last article, it’s time to finally talk about thermometer calibration, or what I like to call “the science behind meaningful temperature measurement.” If the cornerstone of any good measurement is calibration, then the cornerstone of any good calibration is the method(s) used to complete the calibration. Over my next few posts, I will explain some of the details of thermometer calibration. Units of Temperature Throughout history, many units and scales of temperature measurement have been developed for various applications around the world. In fact, historical accounts claim that over 35 different temperature scales had been developed by the 18th century. One of the most famous scales was developed by Daniel Gabriel Fahrenheit around 1714. Fahrenheit was the first scientist to use mercury in a liquid-in-glass thermometer. He used three fixed points to create his temperature scale.
    [Show full text]
  • Lesson 1 the Nature and History of Temperature
    Lektion 1 Sidan 2 av 5 © Pentronic AB 2017-01-19 ---------------------------------------------------------------------------------------------------------------------------------------------------- However, the thermometer had no real practical use until 1714, when the German physicist Daniel Gabriel Fahrenheit developed a temperature scale that made it possible to take comparative measurements. He is also considered to be the inventor of the mercury thermometer as it is today – that is, mercury inside a closed glass tube. It is worth pointing out that the glass thermometers containing mercury that may still be in use are being used by special exemption. Mercury is a stable substance but it becomes dangerous out in the environment. Today we use other liquids such as coloured alcohol. The temperature scales Fahrenheit Fahrenheit created a 100-degree scale in which zero degrees was the temperature of a mixture of sal ammoniac and snow – the coldest he could achieve in his laboratory in Danzig. As the upper fixed point he used the internal body temperature of a healthy human being and gave it the value of 100°F. In degrees Celsius this scale corresponds approximately to the range of -18 to +37 degrees. With this issue Pentronic begins its training in Becausetemperature it can be awkwardmeasurement to achieve .the We upper will fixed start point , he apparently introduced the more practical fixed points of +32°F and +96°F, which were respectively the freezing point of lesson 1 with a historical review and then continuewater and with the temperaturethermodynamics, of a human being’sheat armpittransfer. and quality assurance with calibration. Only after that will we move on to temperature sensors – primarily thermocouples and Pt100s.Fahrenheit’s scale was later extended to the boiling point of water, which was assigned the temperature value of +212°F.
    [Show full text]
  • Thermodynamic Temperature
    Thermodynamic temperature Thermodynamic temperature is the absolute measure 1 Overview of temperature and is one of the principal parameters of thermodynamics. Temperature is a measure of the random submicroscopic Thermodynamic temperature is defined by the third law motions and vibrations of the particle constituents of of thermodynamics in which the theoretically lowest tem- matter. These motions comprise the internal energy of perature is the null or zero point. At this point, absolute a substance. More specifically, the thermodynamic tem- zero, the particle constituents of matter have minimal perature of any bulk quantity of matter is the measure motion and can become no colder.[1][2] In the quantum- of the average kinetic energy per classical (i.e., non- mechanical description, matter at absolute zero is in its quantum) degree of freedom of its constituent particles. ground state, which is its state of lowest energy. Thermo- “Translational motions” are almost always in the classical dynamic temperature is often also called absolute tem- regime. Translational motions are ordinary, whole-body perature, for two reasons: one, proposed by Kelvin, that movements in three-dimensional space in which particles it does not depend on the properties of a particular mate- move about and exchange energy in collisions. Figure 1 rial; two that it refers to an absolute zero according to the below shows translational motion in gases; Figure 4 be- properties of the ideal gas. low shows translational motion in solids. Thermodynamic temperature’s null point, absolute zero, is the temperature The International System of Units specifies a particular at which the particle constituents of matter are as close as scale for thermodynamic temperature.
    [Show full text]
  • Temperature Measurement Temperature Scales TH TC QC QH W
    MAE 334 - INTRODUCTION TO COMPUTERS AND INSTRUMENTATION Temperature Measurement Gabriel Daniel Fahrenheit developed the mercury thermometer in 1714. Mercury has the desirable property of a low freezing point (-38.7 C), a high boiling point (357 C) and a relatively constant coefficient of thermal expansion. Being highly toxic, expensive, slow to respond and impractical to interface with a computer are significant issues preventing its wide spread use. Fahrenheit used a mixture of ice, salt and water as the zero degree reference point and the temperature of the human body as a 96 degree reference point. Anders Celsius created his temperature scale in 1742. Originally zero degrees was the boiling point of water and 100 degrees was the freezing point. These points were later reversed. Temperature Scales As described above original temperature scales were based on certain fixed points. A more rational definition is one based on the Second Law of Thermodynamics. The efficiency of a Carnot engine, , provides a definition of the zero point and a conceptual way of defining intermediate temperatures. W TQCC 11 QTQHHH QH QC TH TC W Figure 1. Carnot engine diagram - where heat flows from a high temperture TH furnace through the fluid of the "working body" (working substance) and into the cold sink TC, thus forcing the working substance to do mechanical work W on the surroundings, via cycles of contractions and expansions. The size of a degree based on the two common scales, Rankine (Fahrenheit) and Kelvin (Celsius), is described above. The Rankine and Kelvin scale are thermodynamic scales and can therefore be used in equations such as the ideal PV gas equation of state.
    [Show full text]
  • MEASURING TEMPERATURE the Thermometer
    MEASURING TEMPERATURE The Thermometer emperature — distinguishing between “the degree of hotness or coldness [of] a body or Tenvironment” (askoxford.com, 2005) — is a phenomenon that has been extensively investigated MIRVETTE CHAMOUN looks over a significant period of time. As a result of this investigation, a device known as the thermometer was at the historical development developed with a sole purpose of measuring the degree of hotness or coldness in a body or environ- of a measurement scale with ment using a particular scale (World Book, 2000). The apparatus constructed has the ability to show the the view of helping children temperature measure, as incorporated within its struc- ture is a liquid that rises and falls in a tube as the understand the role that temperature around it cools or warms (U Learn Today, 2001). This rise and fall is due to the fact that “when mathematics plays in society. the temperature rises, the liquid in the glass tube warms up and molecules move apart causing expan- sion in the liquid, which in turn takes up more space in the tube” (U Learn Today, 2001, p. 6). The history of the thermometer The thermometer took on many different shapes and forms over many years of exploration to get to where it is today. The accuracy and precision of the modern day thermometer came about after many years of trial and tribulation, experienced by an array of inventors and scientists. These scientists and inventors aimed in developing a device that took on the forces of the world around them to measure temperature.
    [Show full text]
  • Ole Rømer's and Fahrenheit's Thermometers
    586 NATURE APRIL 3, 1937 two fixed points, but he was less critical and less I am sorry that Dr. Kirstine Meyer does not rational than R0mer in choosing these points. He accept my suggestion that Romer's zero was obtained retained the freezing point, measured in melting ice, with a mixture of ice and salt (or sal ammoniac). as one fixed point, but he obviously wished to avoid We are all agreed that R0mer chose the boiling the use of a standard thermometer for fixing the point of water as his upper fundamental fixed second. He had termed water of 22!0 Romer (28·5° C.) point and named it 60°. Dr. Meyer would have "blutwarm", and in this way conceived the idea of us believe that, as his lower fundamental fixed using a slightly higher temperature for the second point, R0mer chose the temperature of melting ice, fixed point, namely, body temperature measured called it 7-! 0 and evaluated his zero "by marking "when the thermometer is placed in the mouth or off 7 t parts of the same size below the freezing arm-pit of a healthy man and held there until it point". acquires the temperature of the body"•. This tern· I cannot believe that the great astronomer perature (about 36° C. or 26!0 Romer) is not par· could be so inartistic as to choose arbitrarily ticularly constant, and Fahrenheit therefore felt the the cmious figure of 7! for his lower funda· need of a further fixed point as a check. It appears mental fixed point.
    [Show full text]
  • A Brief History of the Temperature Sensor
    WHITE PAPER A Brief History of the Temperature Sensor The sensations of hot and cold are fundamental to the human That was answered by Gay-Lussac and other scientists experience, yet finding ways to measure temperature has working on the gas laws. During the 19th century, while challenged many great minds. It’s unclear if the ancient Greeks investigating the effect of temperature on gas at a constant or Chinese had ways to measure temperature, so as far as pressure, they observed that volume rises by the fraction of we know, the history of temperature sensors began during the 1/267 per degree Celsius, (later revised to 1/273.15). This led Renaissance. to the concept of absolute zero at minus 273.15°C. This OMEGA white paper summarizes the known history OBSERVING EXPANSION: LIQUIDS AND BIMEtaLS of temperature measurement. After addressing briefly the challenges involved, it goes through the development of Galileo is reported to have built a device that showed changes devices based on: in temperature sometime around 1592. This appears to have used the contraction of air in a vessel to draw up a column of • Observation of expansion water, the height of the column indicating the extent of cooling. However, this was strongly influenced by air pressure and was • The effect of temperature on electrical conductivity little more than a novelty. and resistance • Detection of radiated thermal energy Finally, a note on the origin and development of various temperature scales is provided. THE MEASUREMENT CHALLENGE Heat is a measure of the energy in a body or material — the more energy, the hotter it is.
    [Show full text]
  • Liquid in Glass Thermometers
    Rev. 8/15 SH/GW CHE 253M Experiment No. 1 Temperature Measurement Temperature is probably the most important and most measured property in sci- ence and engineering. Many different temperature-measuring devices have been devised and are in common use today. Each device has its own strengths and weaknesses, and is generally designed for a fairly specific application. As an engineer, it is important for you to select the best possible instrument for the job at hand. This experiment is divided into two parts. In the first part, you will use and exam- ine the accuracy and precision of four different types of thermometers. These are: a liquid in glass thermometer (LIGT), a pyrometer, two thermocouples, and a platinum resistance thermometer (PRT). You should walk away with not only an appreciation for the wide range of temperature measuring instruments available, but also a sense of the limitations of each. Further, you should become aware of the statistical nature of measurement and the myriad variables that can affect accuracy and precision. In the second part we will use thermocouples first in a calorimetry experiment to determine the specific heat capacity of a metal, and then in a separate experiment to cal- culate the convection heat transfer coefficient of an aluminum plate as it cools from an initial high temperature to a lower temperature via free convection. Measuring Temperature – A Brief Historical Background Galileo is credited with inventing the thermometer, circa 1592. In an open con- tainer filled with colored alcohol, he suspended a long narrow-throated glass tube whose end was shaped into a hollow sphere – sort of like an upside-down thermometer.
    [Show full text]