I/O Bus Networks
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Part 2: Packet Transmission
Mesh networks LAN technologies and network topology • Early local networks used dedicated links between each pair of computers LANs and shared media • Some useful properties Locality of reference – hardware and frame details can be tailored for Star, bus and ring topologies each link Medium access control protocols – easy to enforce security and privacy Disadvantages of meshes Links between rooms/buildings • Poor scalability • Many links would follow the same physical path Shared Communication Channels Locality of reference • Shared LANs invented in the 1960s • LANs now connect more computers than any other form of network • Rely on computers sharing a single medium • The reason LANs are so popular is due to • Computers coordinate their access the principle of locality of reference • Low cost – physical locality of reference - computers more • But not suitable for wide area - likely to communicate with those nearby communication delays inhibit coordination – temporal locality of reference - computer is more likely to communicate with the same computers repeatedly 1 LAN topologies • LANs may be categorised according to topology ring bus star Pros and cons Example bus network: Ethernet • Star is more robust but hub may be a • Single coaxial cable - the ether - to which bottleneck computers connect • Ring enables easy coordination but is • IEEE standard specifies details sensitive to a cable being cut – data rates • Bus requires less wiring but is also sensitive – maximum length and minimum separation to a cable being cut – frame formats -
The Design of PROFIBUS-DP HUB Based on FPGA
International Conference on Computer Science and Service System (CSSS 2014) The Design of PROFIBUS-DP HUB based on FPGA Jiao Ping Zhou Tong Lab. of Networked Control Systems Lab. of Networked Control Systems Shenyang Institute of Automation (SIA), Chinese Shenyang Institute of Automation (SIA), Chinese Academy of Sciences China, Shenyang Academy of Sciences China, Shenyang [email protected] [email protected] Abstract—This paper analyzes the PROFIBUS-DP and specified the standard EIA RS-485, and the traffic rate is physical layer signals states, DP time series and other from 9.6kbps to 12Mbps [2, 3, 6]. characteristics. In the past, PROFIBUS-DP HUB common IEC 1158-2 specified the station number of problems of poor universal apply, shape communication is PROFIBUS-DP is 126 (station address from 0 to 125 contain more time-consuming, required message analysis, Drop frame master and slave station) [4]. In the one segment of etc, this paper propose a new design of PROFIBUS-DP HUB PROFIBUS-DP, the maximum station is 32. DP HUB or DP which based on FPGA. The design contain a detector which Repeater device requires the use, if want to connect more used to monitor the physical layer signal state of the DP bus, stations or change the network topology. As figure shown, use of FPGA synthesis logic signal, could control the direction DP HUB or DP Repeater divided the DP network into many of data flow in the physical layer, and Unrelated with the subnet segments [7]. Each interface of DP HUB is a upper layer protocol, without message analysis, compliance the protocol which used the standard RS-485, and Repeater, which can independently drive a PROFIBUS baudrate-adaptive. -
What's New from the OPC Foundation?
Interoperability on the Next Level: OPC-Unified Architecture JAI2010 18.11.2010 – Vigo Stefan Hoppe President OPC Europe [email protected] Agenda • Introduction OPC Foundation • OPC UA details • Advantages of Combined Standards • Demo OPC Foundation • International Industry Standard Organization • OPC Foundation • 407+ Member Companies / 80+ end-users Members • OPC Portfolio • 3500 + Total Companies Build OPC Products = 22000 + Products • OPC UA details • Millions & Millions of OPC Installations • Cooperation • The vision of OPC is secure reliable multi-vendor multi-platform interoperability • for moving information vertically from the data sources through the enterprise of multi-vendor systems (with stops in between…) • For moving information horizontally between data sources on different industrial networks from different vendors; • Not just data but information……. • Reliable, Secure Interoperability is not an option • Collaboration is key to incorporating many multiple “open” standards into an unified open platform architecture World Membership Demographics • OPC Foundation OPC Members By Region • OPC Portfolio • OPC UA details Rest of World , • Cooperation 41 China , 5 China Europe North America Europe , 216 Japan , 142 North America Rest of World Japan , 36 OPC Board of Directors • Reinhold Achatz, Siemens • OPC Foundation • OPC Portfolio Reinhold has been on the OPC Board of Directors longer • OPC UA details than any other board member, he is the founding member for Siemens on the Board of Directors (1997) • Cooperation -
Field Networking Solutions
Field Networking Solutions Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com TYPES OF FIELDBUS NETWORKS* Field Networking 101 Features and Benefits of Fieldbus Networks The combination of intelligent field devices, digital bus networks, and various open communications protocols Fieldbus networks provide an array of features and benefits that make them an excellent choice is producing extraordinary results at process plants in nearly all process control environments. around the world. Compared to conventional technology, fieldbus networks deliver the following benefits: Just as our ability to retrieve, share, and analyze data Reduced field wiring costs has increased tremendously by use of the Internet and - Two wires from the control room to many devices PC network technology in our homes and at our desk- Reduced commissioning costs tops, so has our ability to control and manage our - Less time and personnel needed to perform process plants improved. Digital connectivity in process I/O wiring checkouts - No time spent calibrating intermediate signals manufacturing plants provides an infrastructure for the (such as 4-20mA signals) - Digital values are delivered directly from field flow of real-time data from the process level, making it devices, increasing accuracy available throughout our enterprise networks. This data Reduced engineering/operating costs is being used at all levels of the enterprise to provide - Much smaller space required for panels, I/O racks, and connectivity boxes increased process monitoring and control, inventory and - Fewer I/O cards and termination panels for materials planning, advanced diagnostics, maintenance control system equipment - Lower power consumption by control system planning, and asset management. -
Efficiently Triggering, Debugging and Decoding Low-Speed Serial Buses
Efficiently Triggering, Debugging and Decoding Low-Speed Serial Buses Hello, my name is Jerry Mark, I am a Product Marketing Engineer at Tektronix. The following presentation discusses aspects of embedded design techniques for “Efficiently Triggering, Debugging, and Decoding Low-Speed Serial Buses”. 1 Agenda Introduction – Parallel Interconnects – Transition from Parallel to Serial Buses – High-Speed versus Low-Speed Serial Data Buses Low-Speed Serial Data Buses – Challenges – Technology Reviews – Measurement Solutions Summary 2 In this presentation we will begin by taking a glance at the transition from parallel-to-serial data and the challenges this presents to engineers. Then we will briefly review some of the most widely used low-speed serial buses in industry today and some of their key characteristics. We will turn our attention to the key measurements on these buses. Subsequently, we will present by example how the low-speed serial solution from Tektronix addresses these challenges. 2 Parallel Interconnects Traditional way to connect digital devices used parallel buses Advantages – Simple point-to-point connections – All signals are transmitted in parallel, simultaneously – Easy to capture state of bus (if you have enough channels!) – Decoding the bus is relatively easy Disadvantages – Occupies a lot of circuit board space – All high-speed connections must be the same length – Many connections limit reliability – Connectors may be very large 3 Parallel buses present all of the bits in parallel, as shown in the logic analyzer display. A parallel connection between two ICs can be as simple as point-to-point circuit board traces for each of the data lines. If you can physically probe these lines, it is easy to display the bus state on a logic analyzer or mixed signal oscilloscope. -
Comparison of Network Topologies for Optical Fiber Communication
International Journal of Engineering Research & Technology (IJERT) ISSN: 2278-0181 Vol. 1 Issue 10, December- 2012 Comparison Of Network Topologies For Optical Fiber Communication Mr. Bhupesh Bhatia Ms. Ashima Bhatnagar Bhatia Department of Electronics and Communication, Department of Computer Science, Guru Prem Sukh Memorial College of Engineering, Tecnia Institute of Advanced Studies, Delhi Delhi Ms. Rashmi Ishrawat Department of Computer Science, Tecnia Institute of Advanced Studies, Delhi Abstract advent of the Information age. Optical In this paper, the various network topologies technologies can cost effectively meet have been compared. The signal is analyzed as it corporate bandwidth needs today and passes through each node in each of the network tomorrow. Internet connections offering topology. There is no appreciable signal degradation in the ring network. Also there is bandwidth on demand, to fiber on the increase in Quality factor i.e. signal keeps on LAN. Fiber to the home can provide true improving as it passes through the successiveIJERT IJERTbroadband connectivity for nodes. For the bus topology, the quality of signal telecommuters as well as converged goes on decreasing with increase in the number multimedia offerings for consumers [2]. of nodes and the power penalty goes on increasing. For the star topology, it is observed These different communication networks that received power values of each node at a can be configured in a number of same distance from the hub are same and the topologies. These include a bus, with or performance is same. For the tree topology, it is without a backbone, a star network, a observed that the performance is almost identical ring network, which can be redundant to the performance of ring topology, as signal quality is improved as it passes through the and/ or self-healing, or some successive nodes of the hierarchy. -
SMART HOME SYSTEMS with the Contribution Of
Branko Dvoršak Juraj Havelka Elena Mainardi Hrvoje Pandžić Tea Selič Mario Tretinjak SMART HOME SYSTEMS With the contribution of: Vanja Husein Claudia Pacchiega Goran Švast 2 This publication is part of the SHVET project (https://www.smart-hvet.eu/), and has been made possible with the contribution of (in alphabetical order): Center Republike Slovenije za poklicno Izobraževanje (Slovenia) Centoform (Italy) Ecipa Nordest (Italy) Območna Obrtno-Podjetniška zbornica Krško (Slovenia) Obrtničko učilište – ustanova za obrazovanje odraslih (Croatia) Šolski center Novo mesto (Slovenia) Sveučilište u Zagrebu Fakultet elektrotehnike i računarstva (Croatia) This project has been funded with support from the European Commission. This publication reflects the views only of the authors and the Commission cannot be held responsible for any use which may be made of the information contained therein. 3 TABLE OF CONTENTS page 1 INTRODUCTION 4 1.1 WHAT EXACTLY IS A "SMART HOUSE" 5 1.2 HOME AND BUILDING AUTOMATION 6 1.3 FUNCTIONS YOU CAN DO WITH A SMART HOME SYSTEM 6 2 DIFFERENCE BETWEEN A SMART HOME SYSTEM AND A STANDARD ELECTRIC PLANT 13 2.1 ELEMENTS OF A CLASSIC RESIDENTIAL INSTALLATION 13 2.2 STRUCTURE OF A SMART HOME SYSTEM 18 2.3 MODULES OF A SMART HOME SYSTEM 20 3 SMART HOME SYSTEM TECHNOLOGIES 26 3.1 OVERVIEW OF AUTOMATION AND CONTROL TECHNOLOGIES 25 3.2 WHY KONNEX 28 4 KONNEX 30 4.1 HISTORY OF KNX/EIB AND KONNEX ORGANIZATION 30 4.2 TRANSMISSION MEDIA 30 4.3 NET ARCHITECTURE 32 4.4 TOPOLOGY 35 4.5 ADDRESSES 36 4.6 TELEGRAM 38 4.7 PARAMETERIZATION -
Deliverable Title
Contract No. H2020 – 826098 CONTRIBUTING TO SHIFT2RAIL'S NEXT GENERATION OF HIGH CAPABLE AND SAFE TCMS. PHASE II. D1.1 – Specification of evolved Wireless TCMS Due date of deliverable: 31/12/2019 Actual submission date: 20/12/2019 Leader/Responsible of this Deliverable: Igor Lopez (CAF) Reviewed: Y Project funded from the European Union’s Horizon 2020 research and innovation programme Dissemination Level PU Public X CO Confidential, restricted under conditions set out in Model Grant Agreement Start date: 01/10/2018 Duration: 30 months CTA2-T1.1-D-CAF-005-09 Page 1 of 175 20/12/2019 Contract No. H2020 – 826098 Document status Revision Date Description First issue. Executive summary, Introduction and General 01 27/11/2018 architecture 02 27/06/2019 Contributions of sections 3.1, 3.2, 4.2, 5.2, 5.3, 6.1, 6.2, 6.3, 8 03 03/09/2019 Section 4.1 added. Updated sections 5, 6 and 8 Doc template: corrected footer Abbreviations and Acronyms list: updated Section 3.2: corrected internal references according to CTA2- 04 22/11/2019 T1.1-I-BTD-008-04 Sections 6: updated accoding to CTA2-T1.1-I-BTD-030-09, added new references, corrected internal references 05 05/12/2019 Section 4.2.3: content added 06 06/12/2019 Updated according to CTA2-T1.1-R-SNF-061-01 07 08/12/2019 Section 5.2 and 5.3 added. 08 17/12/2019 Reviews to new contributions applied Whole Document review from CTA2 T1.1 members, TMT and 09 20/12/2019 Safe4RAIL-2 members Disclaimer The information in this document is provided “as is”, and no guarantee or warranty is given that the information is fit for any particular purpose. -
SEW Eurodrive MOVITRAC 31 INTERBUS Fieldbus Interface Manual
T MOVITRAC® 31.. Frequency Inverters INTERBUS Fieldbus Interface (FFI31.. option and size 0/INTERBUS) Manual Edition 1/99 08/198/96 U U C ® L ® L 0922 6915/ 199 Important Notes Important Notes • Read this user manual carefully before you start installation and commissioning work on MOVITRAC® frequency inverters with fieldbus options. This user manual assumes that the user is familiar with and has at his disposal all relevant documentation on the MOVITRAC® system, particularly the installation and operating instructions. • Safety notes: Always follow the safety notes contained in this user manual. Safety notes are marked as follows: Electrical hazard, e.g. during live working Mechanical hazard, e.g. when working on hoists. Important instructions for the safe and fault-free operation of the system, e.g. pre- setting before commissioning.Failure to follow these instructions may result in injury to people and damage to property. • General safety notes for bus systems: The fieldbus option gives you a communications system which allows you to match the MOVITRAC® 31.. drive system to the specifics of your application to a very high degree. As with all bus systems there is, however, the risk of parameters being changed, which will not show outside (i.e. the inverter) but affect the behaviour of the inverter. This may result in unexpected (not uncontrolled, though) system behaviour. • In these instructions, cross-references are marked with an →, e.g., (→ MC_SHELL) means: Please refer to the MC_SHELL User Manual for detailed information or information on how to carry out this instruction. (→ section x.x) means: Further information can be found in section x.x of this user manual. -
Fieldbus Couplers
4 Fieldbus Couple rs 126 Housing Design I with System Powe r Supply Dimensions (mm) 51 x 65 x 100 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 2.5 mm² / 28 ... 14 AWG Strip lengths 8 ... 9 mm / 0.33 in. Housing Design II with System Powe r Supply Dimensions (mm) 62 x 65 x 100 W x H x L (Height from upper edge of the DIN-rail) Housing Design without System Powe r Supply Dimensions (mm) 50 x 65 x 97 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 1.5 mm² / 28 ... 14 AWG Strip lengths 5 ... 6 mm / 0.22 in. Housing Design ECO Dimensions (mm) 50 x 65 x 97 W x H x L (Height from upper edge of the DIN-rail) Wire connection CAGE CLAMP ® Cross sections 0.08 mm² ... 1.5 mm² / 28 ... 16 AWG Strip lengths 5 ... 6 mm / 0.22 in. Modula r I/O- System Ove rview 4 r Fieldbus Couple s 127 Housing Design without System with System Power Supply Power Supply ECO Fi eldbus System Desc ription Item No. Page Fieldbus Couple r, 100 Mbit 750-340 128 Fieldbus Couple r, 2-port, 100 Mbit 750-370 130 Fieldbus Couple r, advanced, 2-port 750-375 132 Fieldbus Couple r, advanced, 2-port, extended operating temperature range: -20 °C ... +60 °C 750-375/025-000 132 Fieldbus Couple r, advanced, ECO, 2-port 750-377 134 Fieldbus Couple r, advanced, ECO, 2-port, extended operating temperature range: -20 °C .. -
Phoenix Contact Automation Catalog
I/O systems in the IP65/67 field 342 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Inhalt 97% Breite skaliert I/O systems in the IP65/67 field More flexible – smaller – faster – better value Program overview Phoenix Contact is actively pursuing these trends with innovative I/O systems Fieldline Stand-Alone 345 for perfect solutions in field wiring and control cabinet construction. Fieldline Modular 361 Fieldline Stand-Alone Fieldline Extension AS-Interface 385 Fieldline Stand-Alone is optimally suitable for recording digital inputs and Rugged Line 401 outputs in harsh ambient conditions in machine and system engineering. Fieldline Stand-Alone is the compact design of the Fieldline I/O system. The combination of Manuals, data sheets, application notes and configuration files input/output modules makes a simple can be found in the download area at www.phoenixcontact.net/ connection of commonly used sensors and download. actuators possible. A Fieldline Stand-Alone IO-Link master has been added to the Fieldline Stand-Alone product range. Use of the IO-Link technology enables seamless You can find information regarding our product and solution-oriented communication from the controller services from page 11 onwards as well as in our online catalog to the sensor/actuator level. (www.phoenixcontact.net/eshop). Fieldline Modular Fieldline Modular offers a cost-effective and high-performance modular solution for complex I/O functions of field wiring. A Fieldline Modular IO-Link master is now available in the Fieldline Modular product range as well. -
Instruction Manual Universal Fieldbus-Gateway UNIGATE® IC- Interbus
your ticket to all buses Instruction Manual Universal Fieldbus-Gateway UNIGATE® IC- Interbus Manual Art.-No.: V3317E Deutschmann Automation GmbH & Co. KG | Carl-Zeiss-Str. 8 | D-65520 Bad Camberg Tel:+49 6434 9433-0 | Hotline: +49 6434 9433-33 | Fax: +49 6434 9433-40 www.deutschmann.com Deutschmann Automation GmbH & Co. KG 1 General introduction . 9 2 The UNIGATE® IC . 10 2.1 Technical introduction . 10 2.2 Availability . 10 2.3 Firmware . 10 2.4 The serial standard interface . 10 2.5 The synchronous serial interface . 10 2.6 The Debug-interface . 10 2.7 UNIGATE® IC hardware survey . 11 3 Hardware design. 12 3.1 Ports . 12 3.2 Pinout . 12 3.2.1 -Boot enable . 13 3.2.2 Load out (SPI-Master: SS0-) . 13 3.2.3 Data out (SPI-Master: SS1-). 13 3.2.4 Data In (SPI: MISO) . 13 3.2.5 Load In (SPI: MOSI) . 13 3.2.6 Clock. 13 3.2.7 -Reset In . 14 3.2.8 LED RESREG-, RBDA, BA . 14 3.2.9 -Config Mode . 14 3.2.10 DbgTX, DbgRx. 14 3.2.11 TE . 14 3.2.12 TX, RX . 14 3.3 Software . 14 3.3.1 Basic line of proceeding . 15 3.4 Connection examples . 15 3.5 Layout examples . 18 3.6 Handling (mounting the UNIGATE® IC on the carrier board) . 20 4 The serial interface . 21 4.1 Overview . 21 4.2 Initialization of the serial interface . 21 4.3 Use of the serial interface . 21 4.4 Further operation modes .