New Wall Plan 0 4' 8' 16' N A3.0 Scale: 1/8" = 1'-0" Main Level

Total Page:16

File Type:pdf, Size:1020Kb

New Wall Plan 0 4' 8' 16' N A3.0 Scale: 1/8 DMC2H Architects professional services coordination 1 2 3 4 5 6 7 8 4401 south quebec street, suite 101 denver, colorado 80237 G o: 303.771.7800 E f: 303.220.1284 E E stamp E 5'-2" E E 11'-9" ALIGN 4" 5'-6" 5'-6" 5" 5" 1 F 5'-11" N 4'-6" 10'-1" 5'-0" 2 ALIGN E 5'-0" E 14'-11" 4'-2" 1 9'-0" 8'-4" 5'-0" 15'-1" 3 7'-3" N 4'-2" 9" N notes E 6'-5" 4'-3" 6 11" 2'-0" 2'-10" 10'-8" DO NOT SCALE THE DRAWINGS, 30'-4" 18" Request verification of dimensions from the SUITE 1 SUITE 2 SUITE 3 Architect as required. 12'-0" N 5 ENTRY 8'-0" 6'-0" The General Contractor shall check and verify all levels, datums and dimensions and shall report any and all errors and omissions 1'-9" D N 14" 14'-10" to the Architect immediately. 4 This drawing is to be read in conjunction with structural,mechanical, electrical and/or 5'-8" E any other consultants drawings that may be applicable. 10" 6'-4" 4'-7" This drawing is the exclusive property of the 11'-9" Architect and must not be reproduced without his written permission. C ALIGN B N E N 3'-2" 2'-2" 6'-0" 14" 3'-2" 8" 6'-0" 12'-6" 9'-10" A 1 NEW WALL PLAN 0 4' 8' 16' N A3.0 SCALE: 1/8" = 1'-0" MAIN LEVEL WALL LEGEND DOOR LEGEND KEYED NOTES EXISTING FACILITY NEW EXTERIOR WALL TO BOTTOM SIDE CONSTRUCT NEW ADA ACCESSIBLE TOILET ROOM WITH ADA CONIFER, COLORADO EXISTING DOOR TO REMAIN WITH NO CHANGES UNLESS 1 OF PERMANENT STRUCTURE ABOVE - E ACCESSIBLE WATER CLOSET, LAVATORY AND GRAB BARS AS NOTED OTHERWISE. CLEAN DOOR, FRAME AND HARDWARE NEW WALL TO MATCH EXISTING INDICATED. CONTRACTOR TO ENSURE THAT ALL CLEAR FLOOR SPACE SECOND FLOOR ADDITION AND ENSURE GOOD WORKING ORDER AT END OF 9064 SOUTH HIGHWAY 285 EXTERIOR WALL CONSTRUCTION. TAKE AND FIXTURE MOUNTING LOCATIONS MEETS ADA STANDARDS. PROVIDE CONSTRUCTION. ENSURE THAT ALL DOOR HARDWARE IS CARE TO ENSURE A CONTINUOUS LOOK ADA COMPLIANT. PROVIDE NEW LEVER HARDWARE AS NEW MIRROR ABOVE LAVATORY. VERIFY ALL FINISHES WITH ARCHITECT. TO ALL SURFACES. REQUIRED TO ENSURE ADA COMPLIANCY. 2 PROVIDE NEW INTERIOR PREFABRICATED STEEL STAIRS WITH NEW WALL TO BOTTOM SIDE OF INTEGRAL HANDRAIL AND GAURD RAIL AT OPEN LANDING AS SHOWN. PERMANENT STRUCTURE ABOVE - R DOOR TO BE REMOVED AND/OR RELOCATED. REUSE NEW STAIR TO HAVE MAX. 7" RISER AND MIN. 11" TREAD WITH 1 1/2" DIA. 3 5/8" METAL STUDS @ 24" O.C. W/ WITHIN BUILT SPACE WHEN POSSIBLE. ALL DOORS THAT HANDRAIL. VERIFY FINAL FINISH FOR ALL STAIR MATERIALS WITH 5/8" TYPE 'X' GYP. BD. EACH SIDE. ARE SCHEDULED TO BE REMOVED THAT ARE NOT TO BE ARCHITECT. REUSED IN NEW WALL CONFIGURATION ARE TO BE RETURNED TO BUILDING OWNER OR DISCARDED UPON NEW WALL TO BOTTOM SIDE OF 3 PROVIDE NEW EXTERIOR PREFABRICATED STEEL STAIRS WITH PERMANENT STRUCTURE ABOVE - BUILDING OWNER'S DIRECTION. INTEGRAL HANDRAIL AND GAURD RAIL AT OPEN LANDING AS SHOWN. 6" METAL STUDS @ 24" O.C. W/ NEW STAIR TO HAVE MAX. 7" RISER AND MIN. 11" TREAD WITH 1 1/2" DIA. 5/8" TYPE 'X' GYP. BD. EACH SIDE. N NEW DOOR OR NEW DOOR LOCATION. REUSE EXISTING HANDRAIL. STEEL IS TO BE PAINTED WITH CONCRETE PAN TREADS. revised DOORS WHEN POSSIBLE. PROVIDE LEVER HARDWARE TO NEW WALL - 3 5/8" METAL STUDS ADA STANDARDS. ALL NEW DOORS ARE TO BE TAKEN 4 PROVIDE NEW ELEVATOR AS INDICATED. CONSTRUCT NEW SURROUND @ 24" O.C. W/ 5/8" TYPE 'X' GYP. FROM EXISTING BUILDING STOCK WHEN POSSIBLE AND ARE WALLS FOR ELEVATOR PER MANUFACTURER RECOMMENDATIONS IN 05/17/05-COUNTY SUBMITTAL BD. EACH SIDE. EXTEND NEW WALL TO TO MATCH EXISTING FLOOR STANDARDS UNLESS ACCORDANCE WITH STRUCTURAL ENGINEERED DRAWINGS. VERIFY ALL UNDERSIDE OF CEILING. OTHERWISE NOTED. DOORS AT EXIT CORRIDORS TO HAVE FINISHES FOR NEW ELEVATOR WITH ARCHITECT. 20 MIN. UL LABEL WITH CLOSER AND SMOKE SEAL. NEW WALL AT ELEVATOR SURROUND - 5 PROVIDE NEW DOUBLE ENTRY DOORS AS INDICATED. NEW DOORS TO scale CONSTRUCT PER ELEVATOR MATCH EXISTING DOORS TO REMAIN IN COLOR AND HEIGHT. PROVIDE MANUFACTURER RECOMMENDATIONS. GLASS INSERT IN DOORS AS SHOWN ON EXTERIOR ELEVATIONS. ALL 1/8"=1'-0" SEE STRUCTURAL DRAWINGS FOR NEW GLASS IS TO MATCH EXISTING GLASS IN COLOR AND REFLECTIVITY ADDITIONAL INFORMATION. EXTEND NEW LEVEL. WALL TO UNDERSIDE OF PERMANENT date drawn ROOF ABOVE. APRIL 15, 2005 6 PROVIDE NEW SIDELIGHT WINDOW AS INDICATED. NEW WINDOW TO MATCH EXISTING WINDOWS TO REMAIN IN COLOR AND MATERIALS. ALL EXISTING WALL TO REMAIN WITH NO NEW GLASS IS TO MATCH EXISTING GLASS IN COLOR AND REFLECTIVITY CHANGES UNLESS OTHERWISE NOTED. drawn by LEVEL. EXISTING WALL OR PORTION OF EXISTING CMA WALL TO BE REMOVED. REMOVE ALL 7 PROVIDE NEW WINDOW AS INDICATED. NEW WINDOW TO MATCH EXISTING POWER, DATA/TELEPHONE WIRING AND/ WINDOWS TO REMAIN IN COLOR, MATERIALS AND HEIGHT. ALL NEW description OR PLUMBING BACK TO ITS ORIGIN. GLASS IS TO MATCH EXISTING GLASS IN COLOR AND REFLECTIVITY LEVEL. REUSE EXISTING HEADER IF POSSIBLE. MAIN LEVEL NEW WALL PLAN sheet number A3.0.
Recommended publications
  • Tips for Measuring Your Kitchen
    G G F H F HWindow External doors BoilerExternal doors Boiler Window Electrical A Electrical socket A Tips for measuringsocket Internal E Internal door E door B your kitchen B Electrical Electrical DIAGRAM 1 DIAGRAMsocket 1 C socket C It’s easy to get swept up in the excitement D Measure lengths D Measure lengths marked A-H of creating your new kitchen. But you’ll need marked A-H to get your measurements right, as they’ll form the basis for your design. So here’s a handy guide so you don’t miss any of those important measurements. G Sloping Sloping F H ceiling External doors ceiling Boiler Window Don’t forget switches, Electrical A sockets socket and most Internal Unit / Unit / E door radiators can be moved if worktop worktop needed. B Electrical DIAGRAM 1 socket C D Measure lengths marked A-H Your floor plan Your wall plan Sketch your room layout Measure your room and openings • Turn over to draw your layout, all you need • The width and height of every window and door. is the general shape. • The distance from the floor to the window and from the top of the window to the ceiling. • Mark the location of windows, doors and archways, Sloping and which way they open, note if they’re internal • Your ceilingceiling height from a few areas for accuracy. or external doors. • If you have a sloping ceiling from a staircase, Measure your room and openings measure the height here too. • The length and width of your room. Measure yourUnit obstacles / worktop TIP: Walls aren’t always straight, so measure from the • The width, depth and height of your meters, boiler, top, middle and bottom if you can.
    [Show full text]
  • Accessory Dwelling Unit - 2 Bedroom General Notes Project Data
    ACCESSORY DWELLING UNIT - 2 BEDROOM GENERAL NOTES PROJECT DATA: 1. The Contractor shall provide adequate stays and bracing of all framing until all elements of design have been DEPARTMENT PROJECT: incorporated in the project. 2. Contractor shall field verify all dimensions prior to commencing with new work. OWNER:_______________________________________________ 3. Work under this permit does not require Special Inspection or structural observation. PLANNING AND BUILDING ADDRESS:______________________________________________ 4. If applicable fire walls should be provided and shall comply with section R302. 5. Location of HVAC subject to field inspection. APN NUMBER:____________________________ 6. HERS Verification required for the HVAC Cooling, HVAC Distribution, & HVAC Fan Systems per T24 Energy Calculation Documentation. Provide completed CalCerts Project Summary Report (PSR) as evidence of Third Party Verification (HERS) STORIES: 1 to Building Inspector prior to final inspection. FIRE SPRINKLERS: YES/NO SITE PLAN NOTES AND REQUIREMENTS - Applicant shall provide a site plan for property showing the location of the proposed ADU. SQUARE FOOTAGE: 746 SQ. FT. - Location of the ADU shall comply with all setback and Fire Separation Distance requirements of OMC Titles 15 and 17 - Site plan shall be drawn to scale. Site Slope shall not exceed 1 . PLANS DEVELOPED IN TYPE OF CONSTRUCTION: V-B 0% COLLABORATION WITH: - Plans are based on 5' minimum Fire Separation Distance. OCCUPANCY GROUP: R-3 ZONING :_____________________ CLIMATE ZONE: 3 BUILDING
    [Show full text]
  • Maddox Residence Material and Sloped to Drain at 1% Minimum
    GENERAL NOTES ABBREVIATIONS OWNER DRAWING INDEX COORDINATION CHRISTOPHER AND SARAH MADDOX A0.0 COVER SHEET / GENERAL INFO A.F.F. ABOVE FINISHED FLOOR J.H. JOIST HANGER 49 RIDGE AVE A0.1 T.F.A. CALCULATIONS SPECIAL NOTE AB JUNCTION BOX 1. IF THESE DRAWINGS ARE NOT 24" x 36" THEY HAVE BEEN REDUCED OR ENLARGED. ANCHOR BOLT J.B. MILL VALLEY, CA 94941 A0.2 EXISTING SITE PHOTOS (DO NOT SCALE DRAWINGS) ABV. ABOVE JST. JOIST THERE IS NO CHANGE IN SCOPE OF WORK FOR THE RESIDENCE PREVIOUSLY APPROVED AC AIR CONDITIONING JNT. JOINT (415) 706-9554 A0.3 EXTERIOR RENDERING BY DESIGN REVIEW. ALL ITEMS MODIFIED OR ADDED ON THIS COVERSHEET IS INDICATED IN 2. THE STANDARD A.I.A. GENERAL CONDITIONS ARE HEREBY MADE A PART OF THESE ADJ. ADJUSTABLE K.D. KILD DRIED A0.4 EXTERIOR RENDERING RED. DRAWINGS. ALUM. ALUMINUM L.H. LEFT HAND ARCHITECT A0.5 PROPOSED MATERIALS APPL. APPLIANCE LAV. LAVATORY TOPO EXISTING TOPOGRAPHIC SURVEY 3. ALL DIMENSIONS ARE TO FACE OF WALL UNLESS OTHERWISE NOTED. ASPH. ASPHALT LT. LIGHT CHARLIE BARNETT ASSOCIATES B.O. BOTTOM OF MAX. MAXIMUM 626 HAMPSHIRE STREET ROS RECORD OF SURVEY SCOPE OF WORK B.U.R. BUILT-UP ROOFING MED. MEDIUM 4. DO NOT SCALE DRAWINGS FOR DIMENSIONS. WRITTEN DIMENSIONS SHALL TAKE SAN FRANCISCO, CA 94110 E1.0 EXISTING SITE PLAN BD MANUFACTURER PRECEDENCE OVER SCALED DIMENSIONS BOARD MFR. (415) 824-0478 A1.0 PROPOSED SITE PLAN NEW 3,004SF, TWO-STORY, SINGLE FAMILY RESIDENCE - THE PROPOSED BLDG. BUILDING MISC. MISCELLANEOUS C1 PRELIMINARY GRADING & DRAINAGE PLAN RESIDENCE INCLUDES; (4) BEDROOMS, (3) BATHROOMS, LAUNDRY/MUD ROOM 5.
    [Show full text]
  • 1206810 C5 3 19 ... He Kitchen 001.Tif Opt.Pdf
    INDEX · NUMBER C5.3 New Trends Planning Kitchens Today The Work Centers The Sink Center The Range Center The Mixing Center Arranging the Work Centers Cabinets and Accessod~s The Planning Center ~-o ,.,.~ .... ,....z r-z xz- OQ ~-4 ISSUED BY THE SMALL HOMES COUNCIL m:z: V)m n" UNIVERSITY OF ILLINOIS BULLETIN o­c .... VOLUME 43, NUMBER 8, SEPTEMBER 19, 1945. Published every Ave days by the University of Illinois. Entered z~ as second-class matter at the post office at Urbano, Illinois, under the Act of August 24, 1912. Office of Pub· Hcalion, 358 Administration Building, Urbano, Illinois. Acceptance for moiling· at the spltciol rote of postage nm provided for in Section 1103, Act of October 3, 1917, authorized Jul~ 31, 1918. ;::z COPYRIGHT, 1945, BY THE UNIVERSITY OF ILLINOIS PRESS. All righh r~served. No port of this Circular may be reproduced in any form without permission in writing from the Publisher. · Material in This Circulor Prepared by MARGARET R. GOODYEAR, DOROTHY J. IWIG, () F. D. MilES, GlADYS J. WARD, VIRGINIA H. WEAVER 01 This Circular ( C5.3) is one of a serres on Small Homes. Requeds for <2irculors should • be addressed to Small Homes Council, Mumford Hou~e, University of Illinois, Urbana. UJ THE KITCHEN IS ALWAYS A CENTER OF ACTIVITY in the home, and its design is of major interest to every family. Recent developments have made the kitchen a more efficient food production unit and at the same time a more pleasant, convenient and sanitary place to work. Improvement in kitchen design began in the 1930's.
    [Show full text]
  • NEW CONSTRUCTION PERMIT APPLICATION # Submit All Permits and Plans To: [email protected]
    NEW CONSTRUCTION PERMIT APPLICATION # Submit all permits and plans to: [email protected] Property Owner Date Property Owner Address: _ Service Address: Property #: Subdivision: Block: Lot: Zoning: (Find property # & legal description At Grayson County Appraisal District Property Search. If this lot is not a legally subdivided lot, please review the information HOW TO CREATE A SUBDIVISION) ** IF HOME WAS BUILT PRIOR TO 1978, YOU ARE REQUIRED BY LAW TO BE A U.S. EPA CERTIFIED RRP RENOVATOR. CALL 214-655-7577 FOR QUESTIONS REGARDING THE RRP RULE ** If there is a variance or other specialty ruling on properly, please attach documents. Check all that apply: Rental? Yes / No New Residence --- sq ft Temp-pole Multifamily --- sq ft Roofing Remodel --- sq ft Pool Garage attached detached --- sq ft Flatwork Carport attached detached --- sq ft HVAC Accessory Bldg --- sq ft Electrical Lot size Gas Building height # of floors Plumbing Off street parking --- sq ft Foundation Sidewalk --- sq ft Demolition Total Project Cost $ Fence License contractors: (provide address, phone # and trade license #) Sign Plumbing Electrical HVAC General Contractor Brief description of work: (construction requires drawing and site plan) Applicant’s Signature Printed Name E-Mail Address: Date Phone # Cell # I agree to conform to all building, plumbing, electrical regulations and city ordinances regulating same. Fees subject to change once inspector has checked work to be done. Applicant must call 903-564-3311 for all inspections and allow 24-hour notice for inspections to be done. State law requires asbestos inspection on commercial property demolitions & remodels. New / Remodel Plan Review Checklist Project Address: Project Name: The City of Whitesboro has adopted the 2017 NEC; the 2018 IBC, IRC, IMC, IPC, IFGC, 2015 IECC, IFC.
    [Show full text]
  • 680 Shipyard Boulevard PB-BMG-0217 January 9, 2017 DRAWINGS SPECI
    Finance Purchasing Division 305 Chestnut Street, 5th Floor Post Office Box 1810 Wilmington, NC 28402-1810 910 341-7830 910 341-7842 fax wilmingtonnc.gov Dial 711 TTY/Voice ADDENDUM NUMBER 1 Fire Station No.5 – 680 Shipyard Boulevard PB-BMG-0217 January 9, 2017 To all holders of Bid Documents; please be advised to the following: The following items supplement, change, delete or add to the Construction Documents as though repeated in full therein. All general conditions, special conditions, etc., as originally specified shall apply to these items. Item No. 1 DRAWINGS a. The following sheets have been revised and are attached to this addendum in PDF format: i. G001 ii. C502 iii. C503 iv. CG101 v. CS101 vi. A301 vii. P101 Item No. 2 SPECIFICATIONS a. Section 012100 ALLOWANCES has been updated and is attached to this addendum. Item No. 3 ADDITIONAL INFORMATION a. See attached SUBSTITUTION REQUEST form. All other terms and conditions remain unchanged. Acknowledge receipt of this Addendum in the space provided in the Proposal. Failure to do so may disqualify the Bidder. Daryle L. Parker, Purchasing Manager Purchasing Division END OF ADDENDUM ONE ATTACHMENTS Addendum 1 Page 1 of 1 ABBREVIATIONS DESIGN TEAM BECKER MORGAN GROUP, INC. ARCHITECT AC. ACOUSTIC F.E.B. FIRE EXTIGUISHER BRACKET PNL. PANEL CATLIN ENGINEERS & SCIENTISTS CIVIL ENGINEER AL., ALUM. ALUMINUM F.E.C. FIRE EXTINGUISHER CABINET P&S POLE AND SHELF A.P. ACCESS PANEL F.F.,FIN.F. FINISHED FLOOR P.S. PROJECTION SCREEN HOWARD T. CAPPS & ASSOCIATES, INC. LANDSCAPE ARCHITECT A.F.F. ABOVE FINISHED FLOOR F.O.S.
    [Show full text]
  • Mendocino County Residential Construction Manual
    Mendocino County Residential Construction Manual 2012 Edition RESIDENTIAL CONSTRUCTION IN MENDOCINO COUNTY I N T R O D U C T I O N MEMBERS OF THE BOARD OF SUPERVISORS Carre Brown John McCowen John Pinches Kendall Smith Dan Hamburg A Building and Development Handbook for Conventional Residential Construction in the County of Mendocino (First Edition) A special Thanks and Acknowledgment to the Residential Construction Manual Team: Chris Warrick – Roger Mobley – Adrienne Thompson – Vale Wippert – Russell Ford Mary Lynn Hunt – Darla Pimlott – Dave Jensen Published by: COUNTY OF MENDOCINO Planning and Building Services 860 North Bush Street, Ukiah, CA 95482 Phone: (707) 234-6650 ¤ Fax: (707) 463-5709 120 West Fir Street, Fort Bragg, CA 95437 Phone: (707) 964-5379 ¤ Fax: (707) 961-2427 This publication was prepared with permission from numerous copyrighted sources. The reproduction of any of the material contained herein without permission from these sources may constitute an infringement of copyrights. CODE DEVELOPMENT IS AN EVOLUTIONARY PROCESS. BUILDING CODES AND OTHER LAWS AND ORDINANCES REGULATING CONSTRUCTION ARE CONTINUOUSLY REVISED AND UPDATED AT THE LOCAL, STATE, AND FEDERAL LEVELS. As a result of the process, the Planning and Building Services Department cannot guarantee that the material presented herein will be accurate and applicable to future construction projects. Information provided is intended to be informative and beneficial and shall be used at the permittee's risk. Department staff should be consulted if questions arise. i THE DEPARTMENT PERFORMS THE FOLLOWING SERVICES : Regulates model construction codes and a variety of State regulations including: energy, conservation, disabled access, sound attenuation, historical building code, fault zone and geotechnical reports, and flood plain management provisions.
    [Show full text]
  • The Heritage at Gum Ranch
    ALL INCLUDED! THE HERITAGE AT GUM RANCH ELLIOTT ADVANTAGE CUSTOM CONSTRUCTION FEATURES Single-bowl undermount stainless steel sink with InSinkErator® Solar electric system E Delta® pullout faucet with soap dispenser High-efficiency tankless natural gas hot water heater E Under-cabinet LED lighting E Hot water recirculation pump with wireless on demand E Ample cabinetry with kitchen island (per plan) Energy-efficient ventilated “cool” roof E USB port for convenient charging of devices E Electric Vehicle-Ready Garage Cat 6 phone outlet High-efficiency Heat Recovery Ventilator E LUXURIOUS MASTER SUITE High-efficiency LED interior and exterior lighting Walk-in closet with mirrored door Complete security alarm system E Luxurious wall-to-wall carpeting and pad Designer packages for flooring, cabinetry, countertops and interior paint Rectangular vitreous china ceramic under-counter vanity sinks Single-bowl undermount stainless steel sink with stainless pullout faucet Large 5 ½’ freestanding soaker tub in utility room E Premium Delta® fixtures E Spacious hallways with 3’ wide entry door Tiled shower floor pan Dramatic 10’ ceilings first floor, 9’ ceilings second floor Framed vanity mirror E Bullnose wall corners Private water closet with elongated ergo-height toilet E Decorative windowsills Solid surface cultured granite countertops and shower surround Elongated toilets in all bathrooms E Medicine cabinet (per plan) Plush wall-to-wall carpeting Prewire for telephone and cable/TV outlet Porcelain floor tile with authentic hardwood look Painted
    [Show full text]
  • Residential Project Plan Requirements
    RESIDENTIAL PROJECT PLAN REQUIREMENTS EFFECTIVE CODE 2018 International Residential Code TOG amendments CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA WIND Seismic Frost Mean Annual Winter SPEED Design Weathering Line Termite Flood Temp Design Temp Category Depth Hazards 115 (ULT) Moderate 34 degrees F Jan 16, 1980 89 (ASD) B Negligible 0 to Heavy Nov 4, 2015 69 degrees F GENERAL REQUIREMENTS Code Item # Reference Description Plans and structural calculations prepared under supervision of an Arizona Professional Registrant must be 1 32-125 sealed per the State of Arizona Board of Technical Registration 2 R106.1 Provide calculations with keyed layouts when structural design is by Arizona Professional Registrant 3 R106.1 Property address is required on all sheets in plan set 4 R106.1 Builder standard plans require subdivision name including neighborhood/parcel/phase on each sheet Square footage summary for (and by) each area type for all livable, garage, storage, and covered 5 R106.1 patios/porches/decks 6 R106.1 Provide Square Footage of structures 7 R302 Fire rated details for walls and projections located within five (5) feet of property line A Soil report is not required for open structures (patios/ramadas) or detached structures/additions of 600 square feet or less if the bottom of the footings are a minimum of 24” below grade. See Soils Investigation and 8 R106.1 Reports document for specific requirements or clarification Plans (and structural calculations) must note by provider and report number what Soil report was used for 9 R401.4 foundation
    [Show full text]
  • Planning the Kitchen
    Volume 3 Article 1 Bulletin P77 Planning the kitchen 11-1-1945 Planning the kitchen Marie Budolfson Iowa State College Follow this and additional works at: http://lib.dr.iastate.edu/bulletinp Part of the Home Economics Commons Recommended Citation Budolfson, Marie (1945) "Planning the kitchen," Bulletin P: Vol. 3 : Bulletin P77 , Article 1. Available at: http://lib.dr.iastate.edu/bulletinp/vol3/iss77/1 This Article is brought to you for free and open access by the Iowa Agricultural and Home Economics Experiment Station Publications at Iowa State University Digital Repository. It has been accepted for inclusion in Bulletin P by an authorized editor of Iowa State University Digital Repository. For more information, please contact [email protected]. Budolfson:mm Planning the kitchen NOVEMBER, Statt Colteg« U tt« - DEC 1.6 1945t — AGRICULTURAL EXPERIMENT STATION —AGRICULTURAL EXTENSION SERVICE, Cooperating IOWA STATE COLLEGE AMES, IOWA Published by Iowa State University Digital Repository, 1945 1 Bulletin P, Vol. 3, No. 77 [1945], Art. 1 CONTENTS Page Ways to improve kitchens............................. ........................ .....560 Convenience in kitchens...—............................................... 560 Types of arrangement......................................... .......................561 Remodeling an old kitchen.......................... ....... ........... ...... .... 563 Kitchen centers ........... ,.564 Planned cabinets.... ................................. ..... ........... .................566 Working heights..........................
    [Show full text]
  • T0.1 Title Sheet LTI Colorpoint Serving Line and Milk Cooler Is Included in Alternate 1
    DE AL SIG H N R ECT U C IT URA AR L S T C D O T C E R R P U E O E R T A S D I T T G I I O E I N CERT.NO O R H C 50382 P R A A NO I A RT L N A H CA RO S H NC EVI LLE E C IK OX ED AR 11/30/18 R M E C H T I IS T G E E C T R 2653 A N I A O N S R C. T OL H H CA R E N. VI L LE Kitchen Renovations at Clyde A. Erwin High School Buncombe County Schools Asheville, North Carolina Location Map CLYDE A. ERWIN HIGH SCHOOL Bid Set LEES 26 ASHEVILLE CREEK ROAD French Broad River 240 63 74 240 Drawing Index Project Alternates N GENERAL ALTERNATE 1: PREFERRED BRAND SERVING LINE CLYDE A. ERWIN HIGH SCHOOL, 60 LEES CREEK ROAD, ASHEVILLE NC 28806 T0.1 Title Sheet LTI Colorpoint serving line and milk cooler is included in Alternate 1. T0.2 Building Code, Life Safety Plan Base bid includes serving line equipment and milk cooler complying T0.3 UL Assemblies with the specifications - see Sections 114000 and 114001. ALTERNATE 2: DISHMACHINE REPLACEMENT ARCHITECTURAL Replacement of designated existing kitchen equipment items as noted in the equipment schedule at Sheet K1.2 is included in D1.1 Demolition Plan Alternate 2. Base bid includes storage and reinstallation of existing A2.0 Interim Cafeteria Plan equipment as noted at Sheet K1.1.
    [Show full text]
  • Bulthaup Product Manual B2
    product manualbulthaup b2 Validity Valid as of July, 1 st, 2009. Prices The price details represent non-binding recommended prices in Euro exclusive of VAT. The first number of the type designation specifies the relevant product group. Examples: 19 M 160 (19 = product group 19) 62 ZSK 3 (62 = product group 60) Please note the different pricings of the various product groups. Terms of delivery and payment Orders placed with bulthaup are subject to our "General Conditions of Delivery and Payment", as accepted by the buyer at the time of placing the order. Five-year limited warranty As a sign of the high quality of our products, we offer a five-year limited warranty on every bulthaup kitchen. The guarantee takes effect from the date of delivery. This warranty covers the proper functioning and quality of workmanship of all parts manufactured by bulthaup. For bulthaup electrical appliances we offer a limited warranty of 24 months. Terms of warranty 1. The warranty applies only when the guidelines contained in the bulthaup cleansing and maintenance manual are fully adhered to. The warranty becomes void if the equipment is mishandled or inadequately cared for, or if the buyer attempts to rectify damage, without the prior agreement of bulthaup, either himself or through the aid of a third party. 2. The warranty does not cover damage caused on the premises of the buyer by natural wear and tear, damp, high ambient temperatures, or other climatic and environmental influences, nor effects due to the physical properties of wood. 3. Electrical appliances and any parts not manufactured by bulthaup are subject only to the terms of warranty of the respective manufacturer.
    [Show full text]