New Wall Plan 0 4' 8' 16' N A3.0 Scale: 1/8" = 1'-0" Main Level
Total Page:16
File Type:pdf, Size:1020Kb
DMC2H Architects professional services coordination 1 2 3 4 5 6 7 8 4401 south quebec street, suite 101 denver, colorado 80237 G o: 303.771.7800 E f: 303.220.1284 E E stamp E 5'-2" E E 11'-9" ALIGN 4" 5'-6" 5'-6" 5" 5" 1 F 5'-11" N 4'-6" 10'-1" 5'-0" 2 ALIGN E 5'-0" E 14'-11" 4'-2" 1 9'-0" 8'-4" 5'-0" 15'-1" 3 7'-3" N 4'-2" 9" N notes E 6'-5" 4'-3" 6 11" 2'-0" 2'-10" 10'-8" DO NOT SCALE THE DRAWINGS, 30'-4" 18" Request verification of dimensions from the SUITE 1 SUITE 2 SUITE 3 Architect as required. 12'-0" N 5 ENTRY 8'-0" 6'-0" The General Contractor shall check and verify all levels, datums and dimensions and shall report any and all errors and omissions 1'-9" D N 14" 14'-10" to the Architect immediately. 4 This drawing is to be read in conjunction with structural,mechanical, electrical and/or 5'-8" E any other consultants drawings that may be applicable. 10" 6'-4" 4'-7" This drawing is the exclusive property of the 11'-9" Architect and must not be reproduced without his written permission. C ALIGN B N E N 3'-2" 2'-2" 6'-0" 14" 3'-2" 8" 6'-0" 12'-6" 9'-10" A 1 NEW WALL PLAN 0 4' 8' 16' N A3.0 SCALE: 1/8" = 1'-0" MAIN LEVEL WALL LEGEND DOOR LEGEND KEYED NOTES EXISTING FACILITY NEW EXTERIOR WALL TO BOTTOM SIDE CONSTRUCT NEW ADA ACCESSIBLE TOILET ROOM WITH ADA CONIFER, COLORADO EXISTING DOOR TO REMAIN WITH NO CHANGES UNLESS 1 OF PERMANENT STRUCTURE ABOVE - E ACCESSIBLE WATER CLOSET, LAVATORY AND GRAB BARS AS NOTED OTHERWISE. CLEAN DOOR, FRAME AND HARDWARE NEW WALL TO MATCH EXISTING INDICATED. CONTRACTOR TO ENSURE THAT ALL CLEAR FLOOR SPACE SECOND FLOOR ADDITION AND ENSURE GOOD WORKING ORDER AT END OF 9064 SOUTH HIGHWAY 285 EXTERIOR WALL CONSTRUCTION. TAKE AND FIXTURE MOUNTING LOCATIONS MEETS ADA STANDARDS. PROVIDE CONSTRUCTION. ENSURE THAT ALL DOOR HARDWARE IS CARE TO ENSURE A CONTINUOUS LOOK ADA COMPLIANT. PROVIDE NEW LEVER HARDWARE AS NEW MIRROR ABOVE LAVATORY. VERIFY ALL FINISHES WITH ARCHITECT. TO ALL SURFACES. REQUIRED TO ENSURE ADA COMPLIANCY. 2 PROVIDE NEW INTERIOR PREFABRICATED STEEL STAIRS WITH NEW WALL TO BOTTOM SIDE OF INTEGRAL HANDRAIL AND GAURD RAIL AT OPEN LANDING AS SHOWN. PERMANENT STRUCTURE ABOVE - R DOOR TO BE REMOVED AND/OR RELOCATED. REUSE NEW STAIR TO HAVE MAX. 7" RISER AND MIN. 11" TREAD WITH 1 1/2" DIA. 3 5/8" METAL STUDS @ 24" O.C. W/ WITHIN BUILT SPACE WHEN POSSIBLE. ALL DOORS THAT HANDRAIL. VERIFY FINAL FINISH FOR ALL STAIR MATERIALS WITH 5/8" TYPE 'X' GYP. BD. EACH SIDE. ARE SCHEDULED TO BE REMOVED THAT ARE NOT TO BE ARCHITECT. REUSED IN NEW WALL CONFIGURATION ARE TO BE RETURNED TO BUILDING OWNER OR DISCARDED UPON NEW WALL TO BOTTOM SIDE OF 3 PROVIDE NEW EXTERIOR PREFABRICATED STEEL STAIRS WITH PERMANENT STRUCTURE ABOVE - BUILDING OWNER'S DIRECTION. INTEGRAL HANDRAIL AND GAURD RAIL AT OPEN LANDING AS SHOWN. 6" METAL STUDS @ 24" O.C. W/ NEW STAIR TO HAVE MAX. 7" RISER AND MIN. 11" TREAD WITH 1 1/2" DIA. 5/8" TYPE 'X' GYP. BD. EACH SIDE. N NEW DOOR OR NEW DOOR LOCATION. REUSE EXISTING HANDRAIL. STEEL IS TO BE PAINTED WITH CONCRETE PAN TREADS. revised DOORS WHEN POSSIBLE. PROVIDE LEVER HARDWARE TO NEW WALL - 3 5/8" METAL STUDS ADA STANDARDS. ALL NEW DOORS ARE TO BE TAKEN 4 PROVIDE NEW ELEVATOR AS INDICATED. CONSTRUCT NEW SURROUND @ 24" O.C. W/ 5/8" TYPE 'X' GYP. FROM EXISTING BUILDING STOCK WHEN POSSIBLE AND ARE WALLS FOR ELEVATOR PER MANUFACTURER RECOMMENDATIONS IN 05/17/05-COUNTY SUBMITTAL BD. EACH SIDE. EXTEND NEW WALL TO TO MATCH EXISTING FLOOR STANDARDS UNLESS ACCORDANCE WITH STRUCTURAL ENGINEERED DRAWINGS. VERIFY ALL UNDERSIDE OF CEILING. OTHERWISE NOTED. DOORS AT EXIT CORRIDORS TO HAVE FINISHES FOR NEW ELEVATOR WITH ARCHITECT. 20 MIN. UL LABEL WITH CLOSER AND SMOKE SEAL. NEW WALL AT ELEVATOR SURROUND - 5 PROVIDE NEW DOUBLE ENTRY DOORS AS INDICATED. NEW DOORS TO scale CONSTRUCT PER ELEVATOR MATCH EXISTING DOORS TO REMAIN IN COLOR AND HEIGHT. PROVIDE MANUFACTURER RECOMMENDATIONS. GLASS INSERT IN DOORS AS SHOWN ON EXTERIOR ELEVATIONS. ALL 1/8"=1'-0" SEE STRUCTURAL DRAWINGS FOR NEW GLASS IS TO MATCH EXISTING GLASS IN COLOR AND REFLECTIVITY ADDITIONAL INFORMATION. EXTEND NEW LEVEL. WALL TO UNDERSIDE OF PERMANENT date drawn ROOF ABOVE. APRIL 15, 2005 6 PROVIDE NEW SIDELIGHT WINDOW AS INDICATED. NEW WINDOW TO MATCH EXISTING WINDOWS TO REMAIN IN COLOR AND MATERIALS. ALL EXISTING WALL TO REMAIN WITH NO NEW GLASS IS TO MATCH EXISTING GLASS IN COLOR AND REFLECTIVITY CHANGES UNLESS OTHERWISE NOTED. drawn by LEVEL. EXISTING WALL OR PORTION OF EXISTING CMA WALL TO BE REMOVED. REMOVE ALL 7 PROVIDE NEW WINDOW AS INDICATED. NEW WINDOW TO MATCH EXISTING POWER, DATA/TELEPHONE WIRING AND/ WINDOWS TO REMAIN IN COLOR, MATERIALS AND HEIGHT. ALL NEW description OR PLUMBING BACK TO ITS ORIGIN. GLASS IS TO MATCH EXISTING GLASS IN COLOR AND REFLECTIVITY LEVEL. REUSE EXISTING HEADER IF POSSIBLE. MAIN LEVEL NEW WALL PLAN sheet number A3.0.