T0.1 Title Sheet LTI Colorpoint Serving Line and Milk Cooler Is Included in Alternate 1
Total Page:16
File Type:pdf, Size:1020Kb
DE AL SIG H N R ECT U C IT URA AR L S T C D O T C E R R P U E O E R T A S D I T T G I I O E I N CERT.NO O R H C 50382 P R A A NO I A RT L N A H CA RO S H NC EVI LLE E C IK OX ED AR 11/30/18 R M E C H T I IS T G E E C T R 2653 A N I A O N S R C. T OL H H CA R E N. VI L LE Kitchen Renovations at Clyde A. Erwin High School Buncombe County Schools Asheville, North Carolina Location Map CLYDE A. ERWIN HIGH SCHOOL Bid Set LEES 26 ASHEVILLE CREEK ROAD French Broad River 240 63 74 240 Drawing Index Project Alternates N GENERAL ALTERNATE 1: PREFERRED BRAND SERVING LINE CLYDE A. ERWIN HIGH SCHOOL, 60 LEES CREEK ROAD, ASHEVILLE NC 28806 T0.1 Title Sheet LTI Colorpoint serving line and milk cooler is included in Alternate 1. T0.2 Building Code, Life Safety Plan Base bid includes serving line equipment and milk cooler complying T0.3 UL Assemblies with the specifications - see Sections 114000 and 114001. ALTERNATE 2: DISHMACHINE REPLACEMENT ARCHITECTURAL Replacement of designated existing kitchen equipment items as noted in the equipment schedule at Sheet K1.2 is included in D1.1 Demolition Plan Alternate 2. Base bid includes storage and reinstallation of existing A2.0 Interim Cafeteria Plan equipment as noted at Sheet K1.1. A2.1 1st Floor Plan A2.2 Signs, Enlarged Plans & Details ALTERNATE 3: KITCHEN EQUIPMENT REPLACEMENT A3.1 Reflected Ceiling Plan Replacement of designated existing kitchen equipment items as A5.1 Exterior Elevations & Wall Sections noted in the equipment schedule at Sheet K1.2 is included in A8.1 Door Schedule & Details Alternate 2. Base bid includes reuse of existing equipment as noted A8.2 Window & Storefront Details at Sheet K1.1. A9.1 Wall Graphics ALTERNATE 4: REFINISH EXISTING TERRAZZO K1.1 Kitchen Equipment Plan Grinding and refinishing existing Dining Room terrazzo is included in K1.2 Kitchen Equipment Plan, Alternates 2 & 3 Alternate 4. Base bid includes stripping and cleaning of existing K1.3 Kitchen Utilities Plans terrazzo except where specifically noted otherwise. K2.1 Kitchen Equipment Details K2.2 Kitchen Equipment Details S1.1 Foundation Plan & Details PLUMBING P0.1 Plumbing - Supply Demolition P0.2 Plumbing - DWV Demolition P1.0 Plumbing - Interim Plan AREA OF RENOVATIONS P1.1 Plumbing - Supply SEE PHASING NOTES THIS SHEET P1.2 Plumbing - DWV P2.1 Plumbing Schedules, Details & Notes MECHANICAL M0.1 Mechanical - Duct Demolition M0.2 Mechanical - Piping Demolition M1.0 Mechanical - Interim Plan ErwinA. High School KitchenRenovations Clydeat Asheville,North Carolina BuncombeCounty Schools M1.1 Mechanical - Ductwork Construction M1.2 Mechanical - Piping Construction M2.1 Mechanical - Details M2.2 Mechanical - Details DINING M2.3 Mechanical - Schedules, Details & Notes KITCHEN ELECTRICAL E0.1 Electrical - Demolition E1.0 Electrical - Interim Plan E1.1 Electrical - Power E1.2 Electrical - Lighting Notes on Phasing E2.1 Electrical - Partial 2nd Floor Plan, Risers, Notes & Legend PORTIONS OF THE WORK SHALL BE COMPLETED E2.2 Electrical - Lighting & Panel Schedules PRIOR TO AUGUST 12, 2019, FOR INTERIM USE OF THE CAFETERIA. MAIN ENTRY REFER TO INTERIM FLOOR PLAN AT SHEET 2.0 FOR SCOPE OF PHASE ONE WORK. DE 1st Floor School Plan/Phasing Plan KE CO AL SIG 1 H N I X R ECT ED A IT URA R RC U RC L S M H A C E T O T I D R T N N T P IS E T0.1 E C R O U R G C E E T A SCALE: 1" = 30' D E S T T I I T O R G I I E N ACTUAL PLAN CERT.NO O R 2653 H P NORTH NORTH C 50382 A A N 11/30/18 R I A O A S R N C. Sheet N I A T L OR N H O TH OL H C AR A CAR N. S H C E N V IL L E EVILLE T0.1 DE AL SIG H N R ECT U C IT URA AR L S T C D O T C E R R P U E O E R T A S D I T T G I I O E I N CERT.NO O R H C 50382 P R A A NO I A RT L N A H CA RO S H NC EVI LLE E C IK OX ED AR 11/30/18 R M E C H T I IS T G E E C T R 2653 A N I A O N S R C. T OL H H CA R E N. VI L LE 2015 NC State Existing Building Code, Work Area Compliance Method, Level 2 Alterations ENERGY SUMMARY ELECTRICAL SUMMARY ENERGY REQUIREMENTS: FOR NEW WORK ONLY and applicable portions of 2012 NC State Building Code - 2009 IBC with NC Amendments The following data shall be considered minimum and any special attribute required to meet the energy code ELECTRICAL SYSTEM AND EQUIPMENT Building Code Summary shall also be provided. Each Designer shall furnish the required portions of the project information for the Method of Compliance: plan data sheet. If performance method, state the annual energy cost for the standard reference design vs. Energy Code: Prescriptive Performance the annual energy cost for the proposed design. ASHRAE 90.1: Prescriptive Performance Lighting schedule Name of Project: Kitchen Renovations at Clyde A. Erwin High School LIFE SAFETY SYSTEMS REQUIREMENTS: ALL SYSTEMS EXISTING Climate Zone: 3 4 5 lamp type required in fixture: Refer to Lighting Fixture Schedule Address: 20 Erwin Hills Road, Asheville, NC 28806 Emergency Lighting: No Yes number of lamps in fixture: Refer to Lighting Fixture Schedule Method of Compliance: Prescriptive (Energy Code) Exit Signs: No Yes - Existing ballast type used in the fixture: Refer to Lighting Fixture Schedule Proposed Use: High School Kitchen Fire Alarm: No Yes - Existing Performance (Energy Code) number of ballasts in fixture: Refer to Lighting Fixture Schedule Owner/Authorized Agent: Mr. Tim Fierle, Director of Facilities and Planning, Buncombe County Schools Phone: 828-2555-5916 Smoke Detection Systems: No Yes Partial Prescriptive (ASHRAE 90.1) total wattage per fixture: Refer to Lighting Fixture Schedule Owned By: Buncombe County Board of Education City/County Private State Email: [email protected] Panic Hardware: No Yes - Existing Performance (ASHRAE 90.1) total interior wattage specified vs allowed: 3110 VS 6328 Code Enforcement Jurisdiction: City County Buncombe State THERMAL ENVELOPE: total exterior wattage specified vs allowed: 210 VS 400 Roof/ceiling Assembly: N/A, Unchanged Additional Prescriptive Compliance LEAD DESIGN PROFESSIONAL: Archtectural Design Studio, Mike Cox LIFE SAFETY PLAN REQUIREMENTS 506.2.1 More Efficient Mechanical Equipment Life Safety Plan Sheet #: T0.2 Exterior Walls: New Walls 506.2.2 Reduced Lighting Power Density DESIGNER FIRM/NAME LICENSE # TELEPHONE EMAIL Description of Assembly: 6" CMU with EIFS on 3" EPS rigid insulation 506.2.3 Energy Recovery Ventilation System Architectural: ADS, MIKE COX, AIA 50382 & 2653 (828)252-0355 [email protected] Fire and/or smoke rated wall locations (Chapter 7) U-Value of total assembly: 0.070 506.2.4 Higher Efficiency Service Water Heating Civil: N/A Assumed and real property line locations 506.2.5 On-site Supply of Renewable Energy Electrical: SUD ASSOCIATES, DAVID BRIGGS PE 30835 (828) 255-4691 R-Value of Insulation: R-11.6 ci [email protected] Exterior wall opening area with respect to distance to assumed property lines (705.8) 506.2.6 Automatic Daylighting Control System Fire Alarm: SUD ASSOCIATES, DAVID BRIGGS PE 30835 (828) 255-4691 [email protected] Plumbing: SUD ASSOCIATES, JEROME HAY, PE 18486 (828) 255-4691 [email protected] Existing structures within 30' of the proposed building Description of Assembly: 6" Metal Stud Walls, EIFS with 2" rigid insulation, gypsum sheathing, R-19 batt Mechanical: SUD ASSOCIATES, JEROME HAY, PE 18486 (828) 255-4691 [email protected] Occupancy types for each area as it relates to occupant load calculation (Table 1004.1.1) insulation, 5/8" gypsum board Sprinkler/Standpipe: N/A Occupant loads for each area U-Value of total assembly: 0.052 Life Safety Plan Legend Structural: N/A Exit Access travel distances (1016) R-Value of Insulation: R-19 + R-10.0 ci Retaining Walls > 5' High: N/A Common path of travel distances (1014.3 & 1028.8) Other: Floors, Slab on Grade: New Interior Slabs Only Dead end lengths (1018.4) NEW 1 HR FIRE PARTITION OR FIRE BARRIER Description of assembly: 4" Slab on Vapor Barrier on 4" Stone Base Clear exit widths for each exit door 2012 EDITION OF CODE FOR: New Construction Addition Upfit U-Value of total assembly: N/R Maximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.1) EXISTING 1 HR FIRE BARRIER EXISTING: Reconstruction Alteration Repair R-Value of Insulation: None CONSTRUCTED: (date) 1973 ORIGINAL USE (s): (Ch.3): E-EDUCATIONAL Actual Occupant load for each exit door RENOVATED: (date) 2006, 2008 CURRENT USE(s) (Ch. 3): E-EDUCATIONAL Schematic plan Note indicating where fire rated floor/ceiling and/or roof structure is provided for purposes of occupancy separation MECHANICAL SUMMARY EXIT PROPOSED USE(s) (Ch. 3): E-EDUCATIONAL Location of doors with panic hardware (1008.1.10) MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT ACCESSIBLE MEANS OF EGRESS Location of doors with delayed egress locks and the amount of delay (1008.1.9.7) Thermal Zone: 4A BASIC BUILDING DATA OCCUP 88 Location of doors with electromagnetic egress locks (1008.1.9.8) winter dry bulb: 12 F OCCUPANT LOAD Construction Type: 1-A II-A III-A IV V-A TRAVEL 72' MAX.