Effects of Captopril on the Distribution of Left Ventricular Output with Ventricular Septa1 Defect
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Blood Vessels: Part A
Chapter 19 The Cardiovascular System: Blood Vessels: Part A Blood Vessels • Delivery system of dynamic structures that begins and ends at heart – Arteries: carry blood away from heart; oxygenated except for pulmonary circulation and umbilical vessels of fetus – Capillaries: contact tissue cells; directly serve cellular needs – Veins: carry blood toward heart Structure of Blood Vessel Walls • Lumen – Central blood-containing space • Three wall layers in arteries and veins – Tunica intima, tunica media, and tunica externa • Capillaries – Endothelium with sparse basal lamina Tunics • Tunica intima – Endothelium lines lumen of all vessels • Continuous with endocardium • Slick surface reduces friction – Subendothelial layer in vessels larger than 1 mm; connective tissue basement membrane Tunics • Tunica media – Smooth muscle and sheets of elastin – Sympathetic vasomotor nerve fibers control vasoconstriction and vasodilation of vessels • Influence blood flow and blood pressure Tunics • Tunica externa (tunica adventitia) – Collagen fibers protect and reinforce; anchor to surrounding structures – Contains nerve fibers, lymphatic vessels – Vasa vasorum of larger vessels nourishes external layer Blood Vessels • Vessels vary in length, diameter, wall thickness, tissue makeup • See figure 19.2 for interaction with lymphatic vessels Arterial System: Elastic Arteries • Large thick-walled arteries with elastin in all three tunics • Aorta and its major branches • Large lumen offers low resistance • Inactive in vasoconstriction • Act as pressure reservoirs—expand -
Central Venous Pressure: Uses and Limitations
Central Venous Pressure: Uses and Limitations T. Smith, R. M. Grounds, and A. Rhodes Introduction A key component of the management of the critically ill patient is the optimization of cardiovascular function, including the provision of an adequate circulating volume and the titration of cardiac preload to improve cardiac output. In spite of the appearance of several newer monitoring technologies, central venous pressure (CVP) monitoring remains in common use [1] as an index of circulatory filling and of cardiac preload. In this chapter we will discuss the uses and limitations of this monitor in the critically ill patient. Defining Central Venous Pressure What is the Central Venous Pressure? Central venous pressure is the intravascular pressure in the great thoracic veins, measured relative to atmospheric pressure. It is conventionally measured at the junction of the superior vena cava and the right atrium and provides an estimate of the right atrial pressure. The Central Venous Pressure Waveform The normal CVP exhibits a complex waveform as illustrated in Figure 1. The waveform is described in terms of its components, three ascending ‘waves’ and two descents. The a-wave corresponds to atrial contraction and the x descent to atrial relaxation. The c wave, which punctuates the x descent, is caused by the closure of the tricuspid valve at the start of ventricular systole and the bulging of its leaflets back into the atrium. The v wave is due to continued venous return in the presence of a closed tricuspid valve. The y descent occurs at the end of ventricular systole when the tricuspid valve opens and blood once again flows from the atrium into the ventricle. -
Effects of Vasodilation and Arterial Resistance on Cardiac Output Aliya Siddiqui Department of Biotechnology, Chaitanya P.G
& Experim l e ca n i t in a l l C Aliya, J Clinic Experiment Cardiol 2011, 2:11 C f a Journal of Clinical & Experimental o r d l DOI: 10.4172/2155-9880.1000170 i a o n l o r g u y o J Cardiology ISSN: 2155-9880 Review Article Open Access Effects of Vasodilation and Arterial Resistance on Cardiac Output Aliya Siddiqui Department of Biotechnology, Chaitanya P.G. College, Kakatiya University, Warangal, India Abstract Heart is one of the most important organs present in human body which pumps blood throughout the body using blood vessels. With each heartbeat, blood is sent throughout the body, carrying oxygen and nutrients to all the cells in body. The cardiac cycle is the sequence of events that occurs when the heart beats. Blood pressure is maximum during systole, when the heart is pushing and minimum during diastole, when the heart is relaxed. Vasodilation caused by relaxation of smooth muscle cells in arteries causes an increase in blood flow. When blood vessels dilate, the blood flow is increased due to a decrease in vascular resistance. Therefore, dilation of arteries and arterioles leads to an immediate decrease in arterial blood pressure and heart rate. Cardiac output is the amount of blood ejected by the left ventricle in one minute. Cardiac output (CO) is the volume of blood being pumped by the heart, by left ventricle in the time interval of one minute. The effects of vasodilation, how the blood quantity increases and decreases along with the blood flow and the arterial blood flow and resistance on cardiac output is discussed in this reviewArticle. -
Valve Replacement Alexander Zezulkal, John Mackinnon2 and D.G
Postgrad Med J: first published as 10.1136/pgmj.68.797.180 on 1 March 1992. Downloaded from Postgrad Med J (1992) 68, 180 - 185 i) The Fellowship of Postgraduate Medicine, 1992 Hypertension in aortic valve disease and its response to valve replacement Alexander Zezulkal, John Mackinnon2 and D.G. Beevers' 'University Department ofMedicine and 2Department ofCardiology, Dudley Road Hospital, Birmingham BT18 7QH, UK Summary: We have investigated the prevalence ofhypertension and the response ofblood pressure to operation in 87 patients with lone aortic valve disease who underwent aortic valve replacement. In patients with aortic stenosis alone 26% were hypertensive pre-operatively (age and sex adjusted blood pressure > 160 systolic and or > 95 mmHg diastolic) and 24% were hypertensive post-operatively. In those with aortic regurgitation alone, hypertension was present in 65% before and 57% after valve replacement using the same criterion. For combined stenosis and regurgitation, the prevalence was 54% and 62%, respectively. The post-operative increase in systolic pressure in patients with aortic stenosis occurred mainly in those with a history of left ventricular failure. In those with aortic regurgitation or combined stenosis with regurgitation, diastolic pressure rose after valve replacement resulting in a prevalence of diastolic hypertension of 44% and 35%, respectively. Blood pressure changes were not predicted by the type of valve inserted nor its size. Our data show that despite severe symptomatic aortic valve disease, systolic hypertension was common in aortic stenosis and diastolic hypertension was found in aortic regurgitation. This underlines the by copyright. importance of blood pressure monitoring in patients following aortic valve replacement. -
Time-Varying Elastance and Left Ventricular Aortic Coupling Keith R
Walley Critical Care (2016) 20:270 DOI 10.1186/s13054-016-1439-6 REVIEW Open Access Left ventricular function: time-varying elastance and left ventricular aortic coupling Keith R. Walley Abstract heart must have special characteristics that allow it to respond appropriately and deliver necessary blood flow Many aspects of left ventricular function are explained and oxygen, even though flow is regulated from outside by considering ventricular pressure–volume characteristics. the heart. Contractility is best measured by the slope, Emax, of the To understand these special cardiac characteristics we end-systolic pressure–volume relationship. Ventricular start with ventricular function curves and show how systole is usefully characterized by a time-varying these curves are generated by underlying ventricular elastance (ΔP/ΔV). An extended area, the pressure– pressure–volume characteristics. Understanding ventricu- volume area, subtended by the ventricular pressure– lar function from a pressure–volume perspective leads to volume loop (useful mechanical work) and the ESPVR consideration of concepts such as time-varying ventricular (energy expended without mechanical work), is linearly elastance and the connection between the work of the related to myocardial oxygen consumption per beat. heart during a cardiac cycle and myocardial oxygen con- For energetically efficient systolic ejection ventricular sumption. Connection of the heart to the arterial circula- elastance should be, and is, matched to aortic elastance. tion is then considered. Diastole and the connection of Without matching, the fraction of energy expended the heart to the venous circulation is considered in an ab- without mechanical work increases and energy is lost breviated form as these relationships, which define how during ejection across the aortic valve. -
67 Central Venous/Right Atrial Pressure Monitoring 579
PROCEDURE Central Venous/Right Atrial 67 Pressure Monitoring Reba McVay PURPOSE: Central venous/right-atrial pressure monitoring provides information about the patient ’ s intravascular volume status and right-ventricular preload. The central venous pressure (CVP) or the right atrial pressure (RAP) allows for evaluation of right-sided heart hemodynamics and evaluation of patient response to therapy. CVP and right-atrial pressure are used interchangeably. PREREQUISITE NURSING EQUIPMENT KNOWLEDGE • Pressure transducer system, including fl ush solution rec- • Knowledge of the normal anatomy and physiology of the ommended according to institutional standards, a pressure cardiovascular system is needed. bag or device, pressure tubing with transducer, and fl ush • Knowledge of the principles of aseptic technique and device (see Procedure 75 ) infection control is necessary. • Pressure module and cable for interface with the monitor • Knowledge is needed of the principles of hemodynamic • Dual-channel recorder monitoring. • Leveling device (low-intensity laser or carpenter level) • The CVP/RAP represents right-sided heart preload or the • Nonsterile gloves volume of blood found in the right ventricle at the end of • Sterile injectable or noninjectable caps diastole. Additional equipment (to have available depending on patient • CVP/RAP infl uences and is infl uenced by venous return need) includes the following: and cardiac function. Although the CVP/RAP is used as a • Indelible marker measure of changes in the right ventricle, the relationship is not linear because the right ventricle has the ability to PATIENT AND FAMILY EDUCATION expand and alter its compliance, changes in volume can occur with little change in pressure. • Discuss the purpose of the central venous catheter and • The CVP/RAP normally ranges from 2 to 6 mm Hg in the monitoring with both the patient and family. -
04. the Cardiac Cycle/Wiggers Diagram
Part I Anaesthesia Refresher Course – 2018 4 University of Cape Town The Cardiac Cycle The “Wiggers diagram” Prof. Justiaan Swanevelder Dept of Anaesthesia & Perioperative Medicine University of Cape Town Each cardiac cycle consists of a period of relaxation (diastole) followed by ventricular contraction (systole). During diastole the ventricles are relaxed to allow filling. In systole the right and left ventricles contract, ejecting blood into the pulmonary and systemic circulations respectively. Ventricles The left ventricle pumps blood into the systemic circulation via the aorta. The systemic vascular resistance (SVR) is 5–7 times greater than the pulmonary vascular resistance (PVR). This makes it a high-pressure system (compared with the pulmonary vascular system), which requires a greater mechanical power output from the left ventricle (LV). The free wall of the LV and the interventricular septum form the bulk of the muscle mass in the heart. A normal LV can develop intraventricular pressures up to 300 mmHg. Coronary perfusion to the LV occurs mainly in diastole, when the myocardium is relaxed. The right ventricle receives blood from the venae cavae and coronary circulation, and pumps it via the pulmonary vasculature into the LV. Since PVR is a fraction of SVR, pulmonary arterial pressures are relatively low and the wall thickness of the right ventricle (RV) is much less than that of the LV. The RV thus resembles a passive conduit rather than a pump. Coronary perfusion to the RV occurs continuously during systole and diastole because of the low intraventricular and intramural pressures. In spite of the anatomical differences, the mechanical behaviour of the RV and LV is very similar. -
The Jugular Venous Pressure Revisited
REVIEW CME EDUCATIONAL OBJECTIVE: Readers will measure and interpret the jugular venous pressure in their patients CREDIT with heart failure JOHN MICHAEL S. CHUA CHIACO, MD NISHA I. PARIKH, MD, MPH DAVID J. FERGUSSON, MD Cardiovascular Disease, John A. Burns School Assistant Professor, John A. Burns School Clinical Professor of Medicine, Department of Medicine, University of Hawaii, Honolulu of Medicine, University of Hawaii; of Cardiology, John A. Burns School The Queen’s Medical Center, Honolulu of Medicine, University of Hawaii; The Queen’s Medical Center, Honolulu The jugular venous pressure revisited ■■ ABSTRACT n this age of technological marvels, I it is easy to become so reliant on them as Assessment of the jugular venous pressure is often inad- to neglect the value of bedside physical signs. equately performed and undervalued. Here, we review Yet these signs provide information that adds the physiologic and anatomic basis for the jugular venous no cost, is immediately available, and can be pressure, including the discrepancy between right atrial repeated at will. and central venous pressures. We also describe the cor- Few physical findings are as useful but as rect method of evaluating this clinical finding and review undervalued as is the estimation of the jugular the clinical relevance of the jugular venous pressure, venous pressure. Unfortunately, many practi- especially its value in assessing the severity and response tioners at many levels of seniority and experi- to treatment of congestive heart failure. Waveforms ence do not measure it correctly, leading to a vicious circle of unreliable information, lack reflective of specific conditions are also discussed. -
JUGULAR VENOUS PRESSURE Maddury Jyotsna
INDIAN JOURNAL OF CARDIOVASCULAR DISEASES JOURNAL in women (IJCD) 2017 VOL 2 ISSUE 2 CLINICAL ROUNDS 1 WINCARS JVP- JUGULAR VENOUS PRESSURE Maddury Jyotsna DEFINITION OF JUGULAR VENOUS PULSE AND The external jugular vein descends from the angle of the PRESSURE mandible to the middle of the clavicle at the posterior Jugular venous pulse is defined as the oscillating top of border of the sternocleidomastoid muscle. The external vertical column of blood in the right Internal Jugular jugular vein possesses valves that are occasionally Vein (IJV) that reflects the pressure changes in the right visible. Blood flow within the external jugular vein is atrium in cardiac cycle. In other words, Jugular venous nonpulsatile and thus cannot be used to assess the pressure (JVP) is the vertical height of oscillating column contour of the jugular venous pulse. of blood (Fig 1). Reasons for Internal Jugular Vein (IJV) preferred over Fig 1: Schematic diagram of JVP other neck veins are IJV is anatomically closer to and has a direct course to right atrium while EJV does not directly drain into Superior vena cava. It is valve less and pulsations can be seen. Due to presence of valves in External Jugular vein, pulsations cannot be seen. Vasoconstriction secondary to hypotension (as in congestive heart failure) can make EJV small and barely visible. EJV is superficial and prone to kinking. Partial compression of the left in nominate vein is usually relieved during modest inspiration as the diaphragm and the aorta descend and the pressure in the two internal -
Chapter 9 Monitoring of the Heart and Vascular System
Chapter 9 Monitoring of the Heart and Vascular System David L. Reich, MD • Alexander J. Mittnacht, MD • Martin J. London, MD • Joel A. Kaplan, MD Hemodynamic Monitoring Cardiac Output Monitoring Arterial Pressure Monitoring Indicator Dilution Arterial Cannulation Sites Analysis and Interpretation Indications of Hemodynamic Data Insertion Techniques Systemic and Pulmonary Vascular Resistances Central Venous Pressure Monitoring Frank-Starling Relationships Indications Monitoring Coronary Perfusion Complications Electrocardiography Pulmonary Arterial Pressure Monitoring Lead Systems Placement of the Pulmonary Artery Catheter Detection of Myocardial Ischemia Indications Intraoperative Lead Systems Complications Arrhythmia and Pacemaker Detection Pacing Catheters Mixed Venous Oxygen Saturation Catheters Summary References HEMODYNAMIC MONITORING For patients with severe cardiovascular disease and those undergoing surgery associ- ated with rapid hemodynamic changes, adequate hemodynamic monitoring should be available at all times. With the ability to measure and record almost all vital physi- ologic parameters, the development of acute hemodynamic changes may be observed and corrective action may be taken in an attempt to correct adverse hemodynamics and improve outcome. Although outcome changes are difficult to prove, it is a rea- sonable assumption that appropriate hemodynamic monitoring should reduce the incidence of major cardiovascular complications. This is based on the presumption that the data obtained from these monitors are interpreted correctly and that thera- peutic decisions are implemented in a timely fashion. Many devices are available to monitor the cardiovascular system. These devices range from those that are completely noninvasive, such as the blood pressure (BP) cuff and ECG, to those that are extremely invasive, such as the pulmonary artery (PA) catheter. To make the best use of invasive monitors, the potential benefits to be gained from the information must outweigh the potential complications. -
The Right Atrial Pulse in Congestive Heart Failure
Br Heart J: first published as 10.1136/hrt.16.4.447 on 1 October 1954. Downloaded from THE RIGHT ATRIAL PULSE IN CONGESTIVE HEART FAILURE BY PAUL KORNER* AND JOHN SHILLINGFORDt From the Department ofMedicine, Postgraduate Medical School, Hammersmith, London Received July 8, 1954 In the course of a study of tricuspid incompetence (Muller and Shillingford, 1954) it was found that a high mean venous pressure in chronic congestive heart failure was frequently associated with an abnormal right atrial pressure curve. We have therefore analysed the right atrial pressure records in 48 patients with and without a raised venous pressure. The purpose of this paper is to show a progressive change in the form of the right atrial pulse as the mean venous pressure rises in patients with cardiac failure. Methods. Forty-eight patients are reported; cardiac disease was present in 44, being rheumatic in 24, hypertensive in 7, thyrotoxic in 4, pulmonary in 3, and of various types in 6 cases: there was no heart disease in the remaining 4 who were catheterized on account of hepatic disease. There was sinus rhythm in 31, auricular fibrillation in 16 and auricular tachycardia with 4:1 block in one. Intracardiac pressure recordings were made by a Statham strain gauge amplified by a direct current amplifier connected to the Elmqvist electrocardiograph. All pressures were measured from a reference plane 5 cm. below the sternal angle. RESULTS The normal right atrial pressure curve (Bloomfield et al., 1946; and Lagerl6f and Werk6, 1948) http://heart.bmj.com/ shows a positive wave "a" beginningjust before, and reaching its peak with, atrial systole; the first part ofthe wave is due to passive filling ofthe right atrium and later to atrial contraction. -
Estimation of Central Systolic Blood Pressure Using an Oscillometric Blood Pressure Monitor
Hypertension Research (2010) 33, 592–599 & 2010 The Japanese Society of Hypertension All rights reserved 0916-9636/10 $32.00 www.nature.com/hr ORIGINAL ARTICLE Estimation of central systolic blood pressure using an oscillometric blood pressure monitor Hao-Min Cheng1,2, Kang-Ling Wang2,3, Ying-Hwa Chen2,3, Shing-Jong Lin1,4, Lung-Ching Chen2,3, Shih-Hsien Sung2,3, Philip Yu-An Ding2,3, Wen-Chung Yu2,3, Jaw-Wen Chen1,4 and Chen-Huan Chen1,2,4 Current noninvasive techniques for assessing central aortic pressure require the recording of an arterial pressure wave using a high-fidelity applanation tonometer. We therefore developed and validated a novel method to estimate the central aortic systolic pressure using an oscillometric blood pressure monitor alone. Invasive high-fidelity right brachial and central aortic pressure waves, and left-brachial pulse volume plethysmography from an oscillometric blood pressure monitor, were obtained at baseline and 3 min after administration of sublingual nitroglycerin in 100 patients during cardiac catheterization. In the initial 50 patients (Generation Group), Central systolic blood pressure was predicted by a multi-variate prediction model generated from the comprehensive analysis of the invasive brachial pressure wave, including brachial late-systolic shoulder pressure value and parameters related to wave reflection and arterial compliance. Another prediction model was similarly constructed from the noninvasively calibrated pulse volume plethysmography. Both models were validated in the subsequent 50 patients (Validation Group) with results: r¼0.98 (Po0.001) and mean difference¼0.5±4.5 (95% confidence interval À8.3 to 9.3) mm Hg for the invasive model, and r¼0.93 (Po0.001) and mean difference¼À0.1±7.6 (95% confidence interval À15.0 to 14.8) mm Hg for the noninvasive model.