measurement‧control CATALOG Reliable Measurement For JETEC Electronics CO., Ltd ៧ᴞ ᑧ WEEK 05YEAR ᇽ Factory & Industrial Automation ፶ Ufnq ፸ 20DAY 06MON. ĦUfnq ᇽ 11 40 œʼn qqn Ħ ⒜ឯ % ńŐij œʼn Ufnq 368HUMIDITY 28. °C

over 30 years experience in applying temperature,

humidity, flow, level, pressure, gas measuremen

as suur reem en tsolutionst s

EARS OF Y E 30 X P N E A R

H I

T E

N

E

C R

E O M 30 Y EARS JETEC ELECTRONICS CO., LTD. Company Background | Contact Info Table of Contents

Abuot JETEC Contact Us Table of Contents

Industrial Automation and Control Solutions If you have any question, please By JETEC developing Dep...... 1

do not hesitate to contact with our Internet of Things System(IOT) ...... 1 JETEC Electronics Company was founded in 1987 and customer service. Wi-Fi Remote Monitoring System ...... 1 started with own private brand, devoted to manufacture ...... 4 We are always pleased to serve Long-range Wireless Integrator thermocouple, temperature sensors and controller. Measurement Instrumentation ...... 6 you at any time. Compact Weather Station ...... 6 Since 1998 we introduced PID controller, temperature and ...... 7 Monday–Friday, 8:00–5:30 Pacific Time Multifunction LED Display humidity sensor, flow meter, level sensor, digital pressure Indoor Air Quality Monitor ...... 9 TEL: +886 (4) 2372-9418 switch and gas detector in the field of machinery, refined Customize Software (j-MoniSoft) ...... 11 FAX: +886 (4) 2372-4272 agriculture, pharmaceutical industry, semiconductor industry Sensors & Transmitters ...... 13 and HVAC engineering. E-mail: [email protected] Temperarue and Humidity Datalogger ...... 13 Website: www.jetec.com.tw Temperarue and Humidity Transmitter ...... 14 In 2013 we set up research and development team with CO / CO2 Transmitter ...... 18 industry extensive experience and provide immediate field Level Transmitter ...... 20 ...... trouble shoot solution. The next year we released new Pressure Transmitter 21 YOTTA SENSE of environmental sensors to continuously Factory Automation Control And Industrial Applications ...... 23 meet customers’ demand. Our team has been working on Flow Meter And Flow Switch ...... 23 developing a new generation's products and expand the Recorder and Data Logger ...... 26 software application as well as the system integration Digital Temperature Controller ...... 27 instruments. Infrared Temperature Sensor ...... 29 Gas Detector ...... 31 We’re aiming to have more flexible application & efficiency HVAC Applications ...... 32 optimization of remote monitoring in Big Data and IoT. Differential Pressure Transmitter ...... 32 ...... Our passion for research and attention to detail in manufac- Air Velocity And Air Flow Transmitter 33 Wind And Rain Sensor ...... 33 turing has made our products renowned for cost effective Water Leak Sensors ...... 34 measurement technology and has built up a good reputation ...... and trust with our customers. Agriculture Weather Sensors 34 Rain And Precipitation Sensor ...... 34 Wind Speed And Wind Direction Sensor ...... 35 SSensorsensors ControllerC SSystemystem Solar Radiation Sensor ( / Quantum Sensor / UV Sensor) ...... 36 TransmitterT RRecorderecorder InteIntegrationgration Soil Sensor (Moisture / Temperature / pH / Oxygen) ...... 39 Water Quality Sensor (pH / EC / ORP / DO ) ...... 39 Barometric Pressure And Leafs Measurement ...... 40

JETEC has a policy of continuous improvement and we reserve the right to upgrade or change specifications without Products & Services: prior notice. The Most Complete Portfolio in the Industry

www.jetec.com.tw www.jetec.com.tw Internet of Things System (IOT) Wi-Fi Remote Monitoring System Internet of Things System (IOT) Wi-Fi Remote Monitoring System

Remote Monitoring solution Net Remote Monitoring System 29.629.6 588 36 8.2 °C % ȝJPñ PV

Wifi-based Remote Monitoring System Monitoring Tool Jetec 636 28 66 38 WL-Net kPa °C % ȝJPñ 接待大廳 24.2244.22 56°C 56 % Analyze and report in 辦公室 24.5244.55 58°C 5 %

機房 310 6.5 30 487 25.1255.11 55°C % lux % % SSP real time using integrated 展示廳 ... 30.1300.11 60°C % ... 停車場 visualization tools. 26.5266.56.55 61°C % + Net JETEC ELECTRONICS CO., LTD.

IoTInternet-based Smart PID controller Net 1 ... 2 ...3 ... 4

Real-time Monitor And Data Logging Remotely Modbus RTU RS485 remote Communication Access to process measurement as thermocouple, pressure, humidity or other sensors without needing anyone on-site. Control System Remote Monitoring Software 1 ... 8 1 2 ... 8 Integrate all sensors and transmit process measurement to real-time data display remotely. Analog Signal RTD, Thermocouple Advanced process controller (Option) ‧Multiple inputs, Upgraded Self-Tuning PID Sensors Type ‧PID Over-Shoot Protection / Ramp Function / Sampling time 250mS Temperatrue, ‧UL, cUL, CE & IP66 approved Humidity, Pressure, Gas, DropBox Flow, Level, Air...etc. Support free DROPBOX to monitor and store collected data any time, any where , wherever you have internet access The Applications

29.6 58 36 Advantage to use WiNet °C % ȝJPñ +DWFKLQJ 0DQXIDFWXULQJ %RLOHUEDNLQJ 63 28 66 Real-time transmit process measure or environment parameter to remote PDFKLQH industries GU\LQJLQGXVWU\ kPa °C % On-site checking 310 6.5 30 desktop or DROPBOX. Achieve remote monitoring and managemen lux % %

Manual meter reading Maximum 8 sensors and controllers can be connected to one WiNet 1 Temp Non-real time feedback Abnormal event detection in real time RH 2 Flow Net JETEC ELECTRONICS CO., LTD. Old way Level Internet-based PID controller ''DWWDD Pressure 3 . . WiNet Wireless RS485 Converter . . TFU 'DWD . .

8 User can use APP and PC software to check the data value promptly Flexibility for different hardware, can provide greater visibility into operations

www.jetec.com.tw 1 www.jetec.com.tw 2 Internet of Things System (IOT) Wi-Fi Remote Monitoring System Internet of Things System (IOT) Long-range Wireless Integrator

Net Specification Long-range Wireless Integrator Electric Specification 1000 Transmit range up to 10km, low power, low costs and is perfect for the IoT applications. Current Consumption 340~820mA during wireless RX/TX and Ethernet activated Power Supply +12V to +24V DC No Wiring Or Trenching, Reduced Installation Working Temperature -10 to +70°C WL-Ra1000 offers an easy, quick, flexible extension WiNet Dimension 108(L) x 96(W) x 41(H) mm and cost effective deployment. Wifi Specification 10km Long-long transmission WSN topological Peer-to-peer/ Star From a few kilometer to 10 kilometer in open area. RF Characteristics IEEE 802.11 b/g/n 2.4GHz 1T1R Bandwidth 20/40MHz Monitoring Software Communication Time 500ms Integrating measurement data from different sensors Maximum Radio Range Any areas with wifi on remote site with real-time reading and data logging. Deriving synthesized information to improve performance Communication and greatly contribute to cost saving. Max Equipment number 8 Device Slave Applications Protocol RTU ‧Remote environmental monitoring Baudrate 9600 to 115200 bauds ‧Smart Green House System Parity bit None ‧Medical Appliances Data bit 8 bits ‧Factory automation measurement and control WL-Ra1000(T) WL-Ra1000(R) Stop bit 1 ‧Building automation measurement and control

Monitoring Interface Advantage to use WL-Ra1000 1、PC software: instant data. Option data logging, excel file download, Curve drawing 2、APP: Instant data, Configuration Sensors

Temp

1000 Wireless Device 1000 Wireless Device 29.6 58 36 8.2 RH °C % ȝJPñ PV

Flow JETEC ELECTRONICS CO., LTD. JETEC ELECTRONICS CO., LTD. 63 28 6666 3838 Level kPa °C % ȝJPñȝJPñ USB Interface Pressure . . 310 6.53 300 487487 . WL-Ra1000(T) WL-Ra1000(R) lux % % SSP (Transceiver) (Receiver)

www.jetec.com.tw 3 www.jetec.com.tw 4 Internet of Things System (IOT) Long-range Wireless Integrator Measurement Instrumentation Weather Station

WSC-120 Specification 1000 Compact Weather Station Electric Specification

Operation Voltage 12-24VDC PH Operation Temperatuer -40~85°C Operation Humidity 5~95% (Non-condensing) Cable length 1m / 2m (optional) WSC-120 is a convenient and model. It can transmit the data high accuracy compact weather to PC software for integration Dimension (mm) 65(L)×115(H)×40(D) (Not include antenna) station, it has monitor system and recording promptly, which is Wireless Specification which integrates multiple weather convenient to analyze and manage. factors. Frequency 920~928MHz WSC-120 also could connect with Transmission Power 920~928MHz @20dBm WSC-120 not only could detect LCD display to show the data instantly. Transmission Distance 1KM~10KM the weather factors, such as temperature, humidity, rainfall, Communication wind direction, wind speed, solar Application: Device Slave radiation, UV, soil moisture, etc. ‧Outdoor Protocol RTU It also has data logging function. ‧Amusement facilities ‧Cranes safety Baudrate 9600bps WSC-120 has provides wireless ‧Agriculture Parity bit 8N1 and RS485 communication signal ‧School

Monitoring Software Specifications: Standard sensors Available Add-On Real-time display, parameter setting, Alert notice, data logging, curve graph, Sensors Email alerts (Pro. Version). Sensors Range Accuracy 7HPS 0~60°C ±0.3°C, ±1C %DURPHWULF3UHVVXUH 6RLOS+ +XPLGLW\ 0~100%RH ±3%RH, ±5%RH 6RODU5DGLDWLRQ 6RLO(& :LQGVSHHG 0~60 m/s ±0.5 m/s, ±3% 4XDQWXP 6RLO7HPSHUDWXUH :LQGGLUHFWLRQ 0~360° ±2° 89LQGH[ 6RLO0RLVWXUH 5DLQIDOO 0~720 mm/hr 1.00mm(resoultion) RWKHUV 㩻㠯⮋ Electric Specification ※ The maximum could addition six more items Power Supply 110V(standard) / 24V(optional) Output signal ModBus RTU RS485 or WIFI

Design Your Weather Station

Output signal (options) : Monitoring Tool (options):

29.6299.6.6

Remote! °C 58

% 36

ȝJPñ 8.2 63 PV kPa 282 PC software - WiNet °C 66

% 38 3103 ȝJPñ

lux 6.5 30

%

% 487 SSP Real time display / Data Logger (by connecting Wifi.)

PC software - j-MoniSoft Real time display / Data Logger / Alarm ModBus RTU RS485 LED Display Real time display / Alarm(option)

www.jetec.com.tw 5 www.jetec.com.tw 6 Measurement Instrumentation Multi-function LED Display Measurement Instrumentation Multi-function LED Display

JTC-x40 Series Muliti-function LED Display Specifications Customization ! Display process values from various transmitters Standard Input Sensors Type Range Accuracy Resolution Digit Remote Software Voice Duotone Temperature -10~65℃ ±0.5°C 0.1°C 3-digit Wi-Fi RS-485 ON/OFF Green / Red Humidity 0~99%RH ±3%RH 1%RH 2-digit JETEC Electronics CO., Ltd ᑧ ៧ᴞ WEEK CO2 0~2000, 3000, 5000 ppm ±(75ppm ±5% of measured value) 1ppm 4-digit 105YEAR ᇽ ፶ Ufnq ፸ 20DAY MON. 06 Ħ ᇽ Available Input (options) œʼn Ufnq 11 40 Input signal Type qqn Ħ ᇽ % ńŐij œʼn Ufnq 368HUMIDITY RTD Pt100, Pt1000 ỹឯ28. °C ⒜ឯ TEMP. Thermocouple Type J, K, T, R, S, N, E 4-20mA, Temperature, Humidity, Wind speed, Wind direction, Rainfall, Barometic Pressure, PM2.5, 0-10V, 0-5V PM10, CO2, CO, O2, O3, NH3, Light level ... etc. JTC-x40TCTC--xx400 Serieseries comecomco e equippedeqquippeduippedppedped with a widewwiiidddee rangeange of larglargelarge LLEDEDD displays can bbee easily viewed Others Time, Count from across a room or in darkd areas. The 4"4 LLED segments are available in red and green. Electric Specification JTC-x40 Series has multiple inputs and optional output to meet most applications. Power Supply 110~220V Work Temperature -10~65°C Features Sensor Type External Sensor with 1.5 meters cable (standard) Voice Alarm New Various functions Dimensions 600×260×50mm(JTC-140), 600×380×50mm(JTC-240), 600×540×50mm(JTC-340) Weight 2.62kg(JTC-140), 3.92kg(JTC-240), 5.41kg(JTC-340) (Not included sensors) Standard Type :When the detect value is over JTC-x40 Series offer various output options. the upper or lower limit, JTC-X140 not only flicker ( Relay, RS485, 4-20mA...etc.) the value but also have voice alarm function. Additional Functions (Option) Timing type : It can announce on the hour or Warning function (Color) Output Signal Relay, 4-20mA, RS485 ModBus RTU, Wi-Fi When the detect value is higher or lower than the setting time by customer Buzzer ≧88dB at 30cm /12 VDC alarm point, the character will alternately flicker Warning Light Remote Monitoring New red /green. Dimensions 95×95×155mm It can connect the wifi and transmit the data to Audio Input ([WHUQDOVSHDNHUVLPSHGDQFHaƻ 7KHVSHDNHUGLGQ¶WLQFOXGHLQWKHVKLSPHQW PC immediately, unaffected by time and location Light weight, structural stability Interface PPPRQR Voice Super light body. Even with the double-sided Alarm 1. ON/OFF Color Distinguish display, the thickness barely only 50mm Functions 5HSRUWRQWKHUHJXODUWLPH 0D[LWFDQVHWWKUHHSDUWLFXODUWLPH  High illumination of duotone Red / Green LED. 7LPHDQQRXQFHPHQWRQWKHKRXU 'LGQ¶WUHSRUWWKHWLPH 2 steps of color changing function for reminder. Obvious at a glance With 4” high of red/green duotone LED, make the RQO\³WLPHGLVSOD\PRGHO´DUHDYDLODEOH Multiple inputs display easier to read from the distance up to 50m. Temperature, Humidity, CO2, CO, O2, Count, Time, Dimension (mm) Voltage, Current...etc. Applications ‧Public institutions Temp. ‧Schools ‧Offices Temp. RH ‧Industrial processes Temp. ‧Warehouses Temp. RH CO2 RH ‧Banks ‧Bus And Railway Stations ‧Airports ‧Hotels, Restaurants

www.jetec.com.tw 7 www.jetec.com.tw 8 Measurement Instrumentation Indoor Air Quality Monitor Measurement Instrumentation Indoor Air Quality Monitor

IAQ-M23 Plus Indoor Air Quality Monitor Specifications Real-Time display and continually monitor the critical parameters of indoor air quality Standard Sensing Method CMOS(temperature & Humidity )、NDIR(CO2、PM2.5) $JURZLQJVFLHQWLILFHYLGHQFHKDVLQGLFDWHGWKDWWKH CO2 0~3000ppm Range Temperature -10~50°C DLULQKRPHDQGEXLOGLQJVFDQEHPRUHVHULRXVO\ Humidity 0~99%RH SROOXWHGWKDQWKHRXWGRRUDLULQHYHQWKHODUJHVWDQG PM2.5 aNjJP PRVWLQGXVWULDOL]HGFLWLHV CO2 ±(75ppm ±5% of measured value) Accuracy Temperature ±0.3°C(20~40°C),“ƒ& RWKHUUDQJH Other research indicates that people spend approx. Humidity ±3%RH (20~80%RH),“5+ RWKHUUDQJH RIWKHLUWLPHLQGRRUV7KXVIRUPDQ\SHRSOHWKH PM2.5 10% relative error risks to health from exposure to indoor air pollution CO2 2.3 inch PD\EHJUHDWHUWKDQULVNVIURPRXWGRRUSROOXWLRQ Temperature 1.5 inch LED Size Humidity 1.5 inch PM2.5 1.5 inch IAQ-M23 Plus LVDFRVWHIIHFWLYHO\ODUJHDLUTXDOLW\ Time 1 inch All In One ! LQGLFDWRULWGHOLYHUUHDOWLPHDFFXUDWHWHPSHUDWXUHand Date 0.6 inch KXPLGLW\FDUERQGLR[LGHDQG30PHDVXUHPHQWV. CO2 , PM2.5, Temp, RH, Time, Date CO2 GLJLWDOV  Temperature GLJLWDOV  6WDQGDUG*UHHQ/(' Humidity GLJLWDOV  Alarm:5HG*UHHQ/(')ODVKLQJ Display PM2.5 GLJLWDOV  Date / Time \\\\PPGGKKPP Red LED Up to 4 Simultaneously (CO2&25+7HPS Multiple Parameter CO2 Indicator - Good /. Normal // Poor unit White LED 6PDOOVOHHNDQGFRPSDFWLQGHVLJQ Compact Ə350×245×50mm Alarm î5HOD\GU\FRQWDFW $9'&9$& Working Conditions -10~50°C、0~99%RH options GDWDORJJLQJPHPRU\IRU&2KXPLGLW\DQGWHPSHUDWXUHYDOXHV Data Logging Power Supply $&a9+] ġ via APP. You can export data to Excel (.csv) file. Dimension 350×245×50mm Mounting :DOOPRXQWLQJ CO2 Indicator )RUTXLFNUHFRJQLWLRQRIDLUTXDOLW\ *22'1250$/3225 Additional Functions (Option) 6WDQGDUGGLJLWFRORXULVUHGDQGJUHHQODUJHHDV\WRUHDGGLVSOD\ Dual-color LED Storage capacity PD[ Data Logging Via Bluetooth connection with APP. Logging Interval 0LQPLQXWHV0D[KRXU (APP for Android and device with Bluetooth BLE) The record will reserve even the sensor power off Memory Output Signal RS485 ModBus RTU

CO2 Indicator Dimension (mm)

PPM 350 3000 0D[LPXPSHUPLVVLEOHYDOXHDWWKHZRUNSODFHGXULQJDQKRXUZRUNGD\ CO2 2500 CO2

PPM 245 Adverse health effects expected PM2.5 TEMP. RH PM2.5 TEMP. 1600 RH PPM )DWLJXHDQGORVVRIFRQFHQWUDWLRQEHFRPHDSSDUHQW °C % YEAR MON. DAY TIME YEAR °C 1000 MON. DAY TIME %

Complaints of stiffness and odors + IAQ-M23

600 IAQ-M23+ 5RRPDLUDFFHSWDEOHOHYHO 450 50 +HDOWKIUHVKDLURXWGRRUV 350

www.jetec.com.tw 9 www.jetec.com.tw 10 Customize Software j-MoniSoft Customize Software j-MoniSoft

Customize Software Monitoring Interface

Low cost, low complexity, more reliable and more stable intelligent environment monitoring system. It can be customized to your demands regarding ! Application: j-MoniSoft allows to monitor 6 instruments at the same time. ‧Environmental monitoring Detecting the value of actual status. ‧Smart agriculture Charts, tables, alarms can be seen in “DISPLAY” mode. ‧Smart building 㩻㠯⮋ ‧Medical devices j-MoniSoft monitor system is constructed by RS485 network, ‧Waste management which achieved an efficient monitor platform. ‧Automation and control ‧Server rooms 6 channels Data Logging Data could be exported as csv. file Use with JETEC sensor with RS485 output, like WSC-120 ‧Food Storage systems Pro version could export xlsx. file. Title of the unit and channels could setting by user weather station and WL-Ra1000 wireless monitoring systerm. ‧Greenhouses (Include data and graph)

Architecture

Graph: The information could export .csv file, Pro ver could export xlsx. file. (Include data and graph) Sensors Optional ‧Thermocouple Output Signal ‧PLC Output Signal ‧T/H Transmitter ‧LED Display Monitoring ‧CO Transmitter Analog, Digital, ‧Controller RS485 Alarm : ‧CO2 Transmitter Wireless...etc. ‧Flow Meter It could setting the upper and lower limit. ‧Level Meter Output Signal ‧Rain Gague If the data value is over the standard, the ‧etc.... RS485 alarm will show up on the scene or have a sound to warning.

Functions ĸ3URYHUFRXOGVHWWLQJWKHV\VWHPWR sent the alarm warning by email. 6 Channel Excel Export 6 Real-time display and to log Export data to a .csv file CHANNEL measure data, alarm events. or .xlsx file (Pro)

Graph Configurable Parameters Graphical real-time and the Device Name, Units, Alarm, past 3 hour historic condition DataLogging Interval... trending from one channels. Choose your version Pro Aalrm Indication E-mail alert The display for each channel Can send alerts to multiple email j-MoniSoft turns red in an alarm condition addresses simultaneously j-MoniSoft-Pro

www.jetec.com.tw 11 www.jetec.com.tw 12 Sensors And Transmitters Temperature And Humidity Datalogger Sensors And Transmitters Temperature And Humidity Trasmitter

SYS-TH-L USB Humdity & Temperature DataloggerSYS-TH Series Humdity & Temperature Transmitter Intuitive Multi-Use Temperature & Humidity Logger for reliable low-cost environment monitoring. For Indoor Applications

SYS-TH-L is an economical solution to monitoring server rooms, storage room, greenhouses, library, SYS-TH series Wall-Mounted Humidity & Temperature office or anyplace where you are concerned about Transmitter is the most versatile room transmitter on the the critical systems damage caused by temperature market. The housing is made of ABS material, stable, or humidity conditions. durable and well vented to provide air flow across the sensor to improve measurement accuracy. The SYS-TH-L record temperature and time values, which can later be analysed using a PC. SYS-TH Series with beautiful appearance and clear LCD display, it also equips with 1 relay output, and provides 0~10V or 4~20mA output. Moreover, it is

SYS-TH-L Temp & RH Recorder able to use a transformer or power supply unit with wall-mounted or desktop mounting options. Applications Features Features ‧Incubators Large easy-to-read LCD display Light Weight, Durable, and Easy–to–Transport Design ‧Building Modbus RTU interface (option) Large Internal Memory, 86,000 log readings ‧Office Fold-out stand and Gourd hole for wall fastening Selectable data sampling rate: 1 second to 24 hours ‧Storage High accuracy and long term stability Easy to Use Menu System, Selectable °C or °F Reserved data will not disappear even the battery is running down Specifications Powered from 2×1.5V AAA batteries or external power (DC 5V) Built-in display shows current, min/max readings, alarm states.... Sensing Method CMOS Temperature 0~60°C Free configuration, review, logs data, and Excel-export software Range Humidity 0~100%RH Temperature ±0.3°C (20~40°C), ±1°C (other range) Accuracy at 25°C Specifications Humidity ±3%RH (20~80%RH), ±5%RH (other range) Analog 0~10V or 4-20mA Output Sensing Method CMOS Relay 5A 30V DC / 250V AC Temperature -20~70°C Communication ModBus 485, 9600, none, 8 bits, 1 stop bit (option) Range Humidity 0~100%RH Sampling Rate 0.3 sec Temperature ±0.3°C (20~40°C), ±1°C (other range) Temperature 0~60°C Accuracy at 25°C Operating Range Humidity ±3%RH (20~80%RH), ±5%RH (other range) Humidity 0~100% RH (non-condesing) Storage Capacity 86,400 (Temp & RH) Display LCD,65×40 mm Logging Interval 1 sec~24 hour (adjustment) Alarm Indication LED (Red) Temperature -30~80°C Power Supply DC 10~24V Storage Range Humidity 0~100% RH (Non-condensing) Resolution 0.1°C、0.1% 56 100 31.53 32 Display LCD,65×40 mm unit:mmunit:mm R4.06 Alarm Indication Film Flicker Power Supply 2×1.5V ‘AAA’ batteries or DC 5V (included) 16 PC connection USB port ʨ 40 100 R4.06 ① USB power Adapter (DC 5V), USB cable (1.8m) Ħ Accessories ② HTLog SYS Software CD Dimension 10×10×31.5 cm RS485 65

www.jetec.com.tw 13 www.jetec.com.tw 14 Sensors And Transmitters Temperature And Humidity Trasmitter Sensors And Transmitters Temperature And Humidity Trasmitter

IND-TH Series Humdity & Temperature TransmitterSpecifications For HVAC Applications General Power Supply DC 12 ~24V Cable Gland M12 (7~4mm) Housing ABS Protection IP66 (not incl. probe) Cable length 2m (IND-THR) Dimensions 108 (L)×96(W)×41(H)mm Output Current 4~20mA (3-wire) Analog Voltage 0~10V (3-wire) Protocol Modbus RTU RS485 Baud rate 9600 bps Digital Parity None Data 8 bits Stop 1 stop bit Temperature IND-TH series is designed to serve the building automation / HVAC market, as well as a wide Sesing Method CMOS variety of general purpose relative humidity monitoring applications. Range -20~60°C Accuracy ±0.3°C(20~40°C)、±1°C ( <20°C or >40°C ) Features Applications Working Range -30~70°C Repeatibility ±0.1°C Optional Voltage or current analogue outputs Heating, Response Time 5 sec. Modbus RTU interface (option) Ventilation Long term stability <0.05°C / year High accuracy and long term stability Air conditioning Humidity Temperature compensation Storage rooms SesinSesingg Method CMOS RRangeange 0~100%RH Wall, duct and remote probe versions give users benefit Building management AAccuracyccuracy ±3%RH(20~80%RH)、±5%RH ( <20%RH or >80%RH ) of cost saving and flexibility WorkinWorkingg RanRangege 0~100%RH (Non-condensing) Optional monitor software (j-MoniSoft) RepRepeatibilityeatibility ±0.2%RH RespResponseonse TTimeime 7 sec. Dimension (mm) LonLongg term stabilitstabilityy <0.05RH / year

IND-THW IND-THD 37 IND-TH --- Software :______ 

ij ij 35.5 Software (Optional) j-MoniSoft General version 97 96 j-MoniSoft Pro Pro version ij

Installation Output Comunication Test Report D Duct None None None   Wall mount 0-10 V Modbus RTU Test report ij W V M X ij R Remote I 4-20 mA

 ※ Test Report- The code (X) just the reference for JETEC company internal procedures, it will not show on the model of the product. 225

CABLE GLAND IND-THR Sensor M16x1.5

 RS485 2m 69

www.jetec.com.tw 15 www.jetec.com.tw 16 Sensors And Transmitters Temperature And Humidity Trasmitter Sensors And Transmitters CO / CO2 Trasmitter

JTC-OTH6 Series Humdity & Temperature TransmitterSYS-C / SYS-G Series Room CO2 Transmitter For Outdoor & Meteorological Applications Room CO Transmitter

JTC-OTH6 Series Outdoor Humidity and Temperature Transmitter SYS-C / SYS-G Series can measure CO2 or CO gas. With Series are designed for demanding outdoor measurements in building wide reading range and better accuracy and stability. With automation or meteorological applications. beautiful appearance and clear LCD display, it also equips with 1 relay output and 1 analog output. JTC-OTH6 Seriesinclude an integrated radiation shield to reduce the influence of solar radiation on temperature and humidity measurements Features and to ensure measurement accuracy in outdoor conditions. The sensor’s superior stability ensures long-lasting accuracy and minimal Modbus RTU interface (option) maintenance throughout the transmitter’s lifetime. CO2 Measuring Method: NDIR Sensor Large easy-to-read LCD display Button to adjust alarm configuration Features Flashing LED indicate that CO2 levels are exceeded With radiation shield for mast mounting Specifications Excellent long-term stability Mutil-wing convection design, rain proof Model SYS-G SYS-C Measure Type CO CO2 Easy to install, dismantle and adjust Sensing Method Semiconductor NDIR Specifications Range 0~100, 0~300, 0~500, 0~1000 ppm 0~2000, 0~3000, 0~5000 ppm ±10PPM (0~100ppm) Sensing Method CMOS Accuracy at 25°C ±15PPM (100~300ppm) ±(75ppm ±5% of measured value) Temperature 0~60°C Range ±15%FS (300~1000ppm) Humidity 0~100%RH Analog 0~10V or 4-20mA Temperature ±0.3°C (20~40°C), ±1°C (other range) Output Accuracy at 25°C Relay 5A 30V DC / 250V AC Humidity ±3%RH (20~80%RH), ±5%RH (other range) Communication ModBus 485, 9600, none, 8 bits, 1 stop bit (Option) Standard 4-20mA Output Sampling Rate --- 3 sec Options Modbus RTU Response Time 10 sec (CO) <30 sec Sampling Rate 0.3 sec Warm Up Time 60 sec <2 min Power Supply DC 10~24V Temperature 0 ~ 50°C Operating Range Humidity 0 ~ 100% RH (Non-condensation) Mounting Dimension (mm) Display LCD, 65×40 mm Alarm Indication LED (Red) Power Supply DC 10~24V

Dimension (mm)

200 56 100 31.5 32

R4.06

64 16 40 100 58 ppmm R4.06

RS485 RS485

65

www.jetec.com.tw 17 www.jetec.com.tw 18 Sensors And Transmitters CO / CO2 Trasmitter Sensors And Transmitters

IND-CD Series Duct Mount CO2 Transmitter JTK-620 Level Transmitter for HVAC Submersible level transmitter designed for the long term monitoring of depth and level measurements of water.

The carbon dioxide level substantially determines the quality Advanced seal technology, reliable amplify circuit and of interior climate, especially in buildings where many people accurate compensation technic ensure high accuracy gather, like meeting rooms, hospitals, schools, cinemas and theaters. and good capability of anti-leakage.

IND-CD Series is the CO2 Transmitter which detect CO2 Features gas of the air, to help optimize the ventilation for creating a Good anti-leakage healthy interior climate. IND-CD Series is highly accurate, Good anti-electromagnetic interference compact and have a long life expectancy, ideal for integrating into your breathing air system. Short response time suitable for dynamic level Specifications measurements

General Power Supply DC 12 ~24V Specifications Cable Gland M12 (7~4mm) Housing ABS Pressure range 0~100mbar to 0~20bar (1M~200M) Protection IP66 (not incl. probe) Sensor element Ceramic material Cable length 2m (IND-THR) Over Pressure 200%FS Dimensions 108 (L)×96(W)×41(H)mm Accuracy ±0.25% Output Supply voltage 24VDC Current 4~20mA (3-wire) Analog Output signal 4...20mA Voltage 0~10V (3-wire) Response time ≦0.001 sec. Protocol Modbus RTU RS485 Long term stability ≦0.2%FS/year Baud rate 9600 bps zero point thermal shift ±0.02%FS/°C Digital Parity None Data 8 bits Protection class IP68 Stop 1 stop bit Compenstated temp. 0~50°C CO2 Working temp. range 0~50°C Sesing Method NDIR Medium temp. range 0~50°C Detection Type Suction Type Housing material 304 stainless steel Range 0~3000ppm Cable material PVC Accuracy ±30ppm+5%F.S. Cable length Standard 10 m Sampling Rate 1Hz Warm Up Time 30 sec. Operating Range -20~80°C, 0~95%RH Repeatability Zero point <±80ppm, 50%F.S.:±8%FSD Dimension (mm) Wiring Applications Dimension (mm)

Building HVAC management 20.40

27 Red ->> V+

Climate technology ij Blue - >> OUT+ 96 Schools, Universities 88 L Meeting Rooms, Library Hospitals, Cinemas, Theatres 86.73 108 41

www.jetec.com.tw 19 www.jetec.com.tw 20 Sensors And Transmitters Pressure Trasmitter Sensors And Transmitters Pressure Trasmitter

JPT-131 Series JPT-131S Series Pressure Transmitter For General Purpose Pressure Transmitter With Flush Diaphragm

JPT-131 Serieswith numerous options of process connection JPT-131S Series is developed for general purpose in and electrical interface. JPT-131 Series can fit most industrial industrial applications. Available in numerous options pressure measurement applications. JPT-131 Series consists S PP1 S PP2 of process connection and electrical interface. of a ceramic diaphragm and stainless steel wetted part, and stainless steel housing. JPT-131S Series due to a flush diaphragm process connection, consists of a stainless steel diaphragm and JPT-131LJis able to reach the environmental housing, it can be used for measurements corrosive protection rating up to IP65 (options). gases or liquids compatible with SUS 316L

Applications Features Machine installations Low hysteresis and high repeatability Industrial process control Working temperature 0~80°C, 0~180°C (option) Level / Depth Instrumentationref Solid and durability Environmental monitoring Heating and ventilation Specifications Flush Diaphragm Diaphragm Specifications Type Pressure Range※ -1.... 0~600 bar(JPT-131), 0~600 bar (JPT-131LJ) Over Pressure 2~880 bar Sensor Type Ceramic material Pressure Type Gauge Gauge, Absolute, Compound Gauge Accuracy ±0.5% / ±0.25% Pressure Range※ 0~70 bar 0~20 bar -1~0, 0~0.1 to 0~1000 bar Pressure Port PT1/2”, PT1/4”, G1/2”, G1/4”, 7/16”-20UNF Over Pressure 200%FS 200%FS Current 4~20mA (2 wire) Output Sensor Type silicon oil-filled sensor silicon oil-filled sensor Voltage 0~10V, 1~5V, 0~5V (3 wire) Accuracy ±0.5% or ±0.25% ±0.5% or ±0.25% Temperature 0~60°C Working Range Current 4~20mA 4~20mA 4~20mA Humidity 0~95%RH Output Voltage 0~5V 0~5V 0~10V, 1~5V, 0~5V Temperature 0~55°C Ambient Range Working Standard 0~80°C 0~80°C 0~80°C Humidity 0~75%RH (non-condensation) Temp. Range Option ~180°C --- ~180°C Power 12~32VDC Ambient Range 0~85°C 0~85°C Load Resistance <1000 Ohm Stability <=0.2%FS/year <=0.2%FS/year Stability <0.3 %FSO/year @25°C Pressure Port G1/2”, M20*1.5 Clamp-flange PT1/2”, PT1/4”, G1/2”, G1/4” Sensitive <=0.3 %FSO/year @25°C Power 24VDC 24VDC ※ see Pressure Range Table ※ see Pressure Range Table Pressure Range MODEL:JPT-131 / JPT-131S / JPT-131LJ 1.Gauge pressure 2.Sealed gauge 3.Absolute pressure 4.Compound pressure Dimension (mm) G-xxx Range S-xxxx Range A-xxx Range R-xxx Range G-L01 0...0.1 bar S-100 0...100 bar A-001 0...1 bar R-000 -1...0 bar 25±3 30±3 45±3 25±3 30±3 20 G-L02 0...0.2 bar S-200 0...200 bar A-002 0...2 bar R-001 -1...1 bar PT1/2" G-L05 0...0.5 bar S-250 0...250 bar A-990 others on customer R-002 -1...2 bar G-001 0...1 bar S-400 0...400 bar R-005 -1...5 bar PT1/4" G1/2" G-002 0...2 bar S-600 0...600 bar R-010 -1...10 bar ij ij G-005 0...5 bar S-990 others on customer R-020 -1...20 bar G1/4" G-010 0...10 bar R-050 -1...50 bar Other G-020 0...20 bar R-990 others on customer G-050 0...50 bar JPT-131 / JPT-131S JPT-131LJ G-990 others on customer

www.jetec.com.tw 21 www.jetec.com.tw 22 Factory Automation Control And Industrial Applications Flow Meter And Flow Switch Factory Automation Control And Industrial Applications Flow Meter And Flow Switch

Flow Meters For Liquids, Gases And Steam Flow Meters For Liquids Karman Vortex Flow Meter Karman Vortex Flow Meter Impeller Flow Meter Ultrasonic Vortex Flow Meter Prefect choice for extremely low flow measurement in many industrial of liquid and gas applications. Compact Flow Sensors For Liquids

Electromagnetic Flow Sensor - Suitable for machines of FAC Impeller Flow Sensor - Capable of various liquids Reversal of the display RoHS RoHS KSL Series .6//$QG.6// FS Series USL-20L Measures the flow rate and Measures the flow rate, $ODUPRXWSXW$QDORJRXWSXW Excellent chemical resistance; temperature temp. and integrated values /&'GLVSOD\FRORU/(' VPDOOVL]H DSSOLFDEOHWXEHĭ Built-in lithium battery Range : 0.5~5 to 7~50 (L/min) Range : 10~80 or 20 ~160 (L/min) Range : 0.5~3 L/min to 5~30 L/min Range : 2~20 L/min Accuracy : FS ±2.0% Integration: 0 to 999999 L Accuracy : FS ±2.5% Output : 0~10V, 1~5V, 4~20mA VN VNS ND NW Output : 0-10V, 4-20mA, Pulse, Accuracy : FS ±2.0% Output : 0-10V, 1-5V, 4-20mA, Accuracy : ±2.0%F.S. Outstanding reliability with no Excellent chemical resistance Amplifier built-in magnetic ,QVWDQWDQHRXV)ORZUDWH Alarm Output : Open collector A or B Output : 0-10V, 4-20mA, Pulse (integration) Pulse, relay, open collector(options) Working Pressure :1 MPa moving parts sensor Integrating Flow Volume Working Pressure :1 MPa (<10kgf/cm2) Alarm : MOS-FET ON or OFF Working Pressure :0.97 Mpa Fluid : Pure Water, Industrial water or corrode PFA Range : 0.05~1 L/min to 3.0~60L/min Range : 0.3~3 L/min to 3.0~60 L/min Fluid : Industrial water, water Fluid : Industrial water, water Fluid : Industrial water, water Fluid Temperature : 0 ~ 100°C 2 selectable outputs : Unitpulse, High-density pulse,Warning,Switch Output : Open collector pulse Fluid Temperature : 0~90°C Fluid Temperature : 0~60°C Fluid Temperature : 0~60°C (~150°C) Wetted Material : PFA Accuracy : ±2.0%RS, ±0.4%FS Accuracy : ±2%RS Connection : RC 3/8", RC 1/2" Connection : RC 1/2", RC 1” Connection : RC 3/8", RC 1/2", RC 1/4" Connection : Rc 3/8" Working Pressure : <1 MPa Working Pressure : 0~1 MPa (10Bar) Liquid Viscosity : 0.5-1.5 mPa·s Fluid Conductivity : ≧50 μS/cm Fluid Conductivity : >14 ms/cm Working Pressure : 1MPa (at the time of fluid temperature of 20°C) Karman Vortex Flow Meter Karman Vortex Flow Switch Impeller Flow Switches Flow Control Valve Fluid Temperature : 0~60°C Fluid Temperature : 0~40°C Fluid Temperature : 0~60°C, 0~70°C Fluid Temperature : 0~60°C RoHS RoHS Connection : R1/2, R1 Connection : 16A, 20A Connection : R1/2

Elliptic Gears Flow Sensor - Microflow sensor Capacitivee E Electromagnetic FlowsensorSmall-size Flowsensor QuickQick QuickQick RoHS RoHS fitting fitting

36//$QG36// 36:/// PP-5L FCV

Simple structure, easy Easy alarm setting with a Separate converter & detector. Adjust valve opening automatically Built-in plumbing with quick fasteners rotary switch Ideal for small spaces of installationaccording to flow rate setting value lithium battery Range : 0.5~5.0 or 5.0~30.0 (L/min) Range : 0.5~5.0, 1.5~10.0 , 5.0~30.0 (L/min) Range : 0.5~5L/min Range : 0~30L/min Output : 0~10V, 4~20mA Switch Output : ON / OFF Accuracy : FS ±5% Output: 0-10V, 1-5V, 4-20mA, Alarm OF-Z OF-W CX 1'9 Accuracy : ±2%F.S. Accuracy : ±2%F.S. Output : Open Collector Input : 0-10V, 4-20mA, ON/OFF(Valve opening) Suitble for measuring oil and ,QVWDQWDQHRXV)ORZUDWH Resistant to deposits and Superior repeatability, low Working Pressure :1.0 MPa Working Pressure :1.0 MPa Response Time : 2sec Working Pressure :0.49 MPa various liquids Integrating Flow Volume resistant to foreign substances pressure drop, light weight Fluid : Industrial water, water Fluid : Industrial water, water Working Pressure :1 MPa (<10kgf/cm2) Fluid : Industrial water, water Range : 0.017~0.85 to 0.7~5 L/min Range : 0.0085~0.85 to 0.7~5 L/min Range : 0.5~15 to 2.0~60 L/min Range : 1~10 L/min Fluid Temperature : 0 ~ 90°C Fluid Temperature : 0 ~ 90°C Fluid : Industrial water, water Fluid Temperature: 0~60°C Output : Voltage pulse, Open collector output Output : NPN, PNP, 1~5V, 4~20mA Output : Pulse Display : 2colors LED (alarm) Display : 2colors LED (alarm) Fluid Temperature : 0~60°C Connection : RC 3/8" Accuracy : ±2%RS Accuracy : ±2%F.S. Accuracy : Within ±7%RS Connection : Rc 3/8" Connection : Rc 3/8" Connection : RC 3/8” Power Supply : DC 24V±10% Liquid Viscosity : 0.3~0.8mPa·s to 5.0~200mPa·s Working Pressure : 0 ~ 1 MPa Working Pressure : Up to 0.75 MPa Working Pressure : 0.5MPa Fluid Conductivity : 5μS/cm ~ 3mS/cm Measurable fluid : City water Flow Meters Quick Selection Guide Fluid Temperature : -10~70°C Fluid Temperature : 0~60°C Fluid Temperature : 0 ~ 85°C Fluid Temperature : 0 ~ 40°C Connection : R1/2, R1/4 Connection : Rc3/8, Rc1/2, Rc3/4 Connection : Rc1/4 Impeller Type Karman Vortex Type KSL- MODEL FS-S FS-AR FS-N FS-C PP-5L KSL PSL PSW USL-20L FCV Compact Flow Sensors Quick Application Guide / Ultrasonic Flow Meters Digital Display ●●●Ʉ ● LCD Display; High Durability LCD Display Temp. Measurement ●●● Built-in batteries Integration ● MODEL VNVNS ND OF-Z NW OF-WCX NDV Alarm Output ● ●●●●1) ● ●● ● High Accuracy Ʉ Ʉ Ʉ Ʉ Ʉ ɄɄ 0-10 V Ʉ Ʉ ● Ʉ Ʉ Ʉ Ʉ Ʉ High Durability Ʉ Ʉ Ʉ Output 1-5 V Ʉ Ʉ Ʉ Compact Ʉ Ʉ Ʉ Ʉ Ʉ 4-20 mA Ʉ Ʉ Ʉ Ʉ Ʉ Ʉ Suitable for use in machines Ʉ ɄɄɄ Ʉ Ʉ Pulse Ʉ ● ɄɄ Ʉ Ʉ Low Flow Ʉ Ʉ Ʉ Ʉ Polyacetal Ʉ ɄɄ Ʉ Chemical Resistance Ʉ Ʉ Ʉ SUS304・316 Ʉ Ʉ Ʉ ● Resistant To Deposits Wetted Ʉ Materials PP/PPS・SS316/304 ●● Resistant To Foreign Substances Ʉ fluorine resin Ʉ Ʉ Ʉ Pulsating Flow Ʉ Ʉ Ʉ Ʉ Ʉ PFA ● Batch Controller Ʉ Ʉ Ʉ Ʉ Ʉ Ʉ Flow Control ● Warm Water ɄɄ Ʉ Ʉ ● : Standard ○ : Optional 1) Only the flow rate alarm

!

www.jetec.com.tw 23 www.jetec.com.tw 24 Factory Automation Control And Industrial Applications Flow Meter And Flow Switch Factory Automation Control And Industrial Applications Recorder and Data Logger

Flow Meters For Liquids / Electromagnetic Water Meters Recorder / Data Logger Ultrasonic Flow Meter Electromagnetic Flow Meter Electromagnetic Water Meter Tracking parameters variables as temperature, humidity, pressure, flow and pH...etc.

The Paperless Recorders Pen or Multipoint Recorder Touch Panel Paperless Recorder Multi-function Data Logger and Data loggers suited for applications such as :

‧Drying ovens TRA WX SU SY ‧Environmental monitoring Turndown ratio 50:1, Negligible Superior repeatability, low High accuracy measurement whether large continuous or ‧Fermentation processes pressure drop, High durability pressure drop, light weight small flowrates, Bi-directional flow measurements ‧Flow monitoring TRM-10C TRM-00J JS210 Range : 0.6~30 to 4~200 m3/h Range : 360~950 to 6000~15000 L/min Measurement range : 0.25~0.4 to 6.25~10 m3/hMeasurement range : 0.0625~0.1 to 0.625~1 m3/h ‧Freeze drying 1 pen, 2 pen / 6 point 6 Channel, 7” touch panel USB interface, Large LCD 2.64~132 to 17.6~880 (US gal/min) Accuracy : ±1.0%RD, ±0.5%FS 0.4~5 to 10~1250 m3/h 0.1~31.25 to 1~312.5 m3/h ‧Sterilization ±2%, ±5% Accuracy : Output : Pulse, 4 to 20mA Output : External Open (Options) Output : External Open (Options) ‧Heat treating Measuring Cycle : 125ms (pen) Measuring Cycles :100ms Inputs : 4-20mA / 0-5V / 0-10V (options) Output : Pulse, 4 to 20mA Working Pressure :2MPa, 1MPa Working Pressure :1 MPa / 2 MPa Working Pressure :0.75 MPa ‧Catering vehicles 10s/6ch, max (multipoint) Recording Cycles :100ms-60min Measuring range :-999~9999 Working Pressure :1NPa, 10Bar (145 PSI) Fluid : Industrial water, water Fluids : City water, plant water, agricultural water Fluids : City water, plant water, agricultural water ‧Cold storage Input Type Voltage,: Current, Thermocuple, RTD Alarm Output :1 points Mounting :Wall-mounted and Desk-top Fluids : Drinking / industrial /pure water, seawater Fluid Conductivity : ≧20 μs/cm Fluid Conductivity : ≧50 μs/cm Fluid Conductivity : ≧50 μs/cm ‧Blood banks Communication :RS232C(standard), Input Type: Voltage, Current, Thermocuple, RTD Memory :43,000 log readings (max.) Fluid Temperature : 0 to 50°C Fluid Temperature : 0 to 60°C Fluid Temperature : 0~30°C Fluid Temperature : 0~30°C Cold-chain transporation RS485(option) Memory : Recordable to SD Card, USB memory Channel :4-20mA input with 2 channels can Connection : 1½, 2, 3, 4 Connection : φ50~100mm Connection : φ50~350mm Connection : φ50~150mm ‧ (refrigerated trucks) Alarm : 3 alarm output / 6 alarm output Communication : RS485, USB2.0 record 2-channel 4-20mA signals Certificate UL,: CSA, CE approvals Certificate UL,: RoHs, CE approvals Power supply : 2×1.5V battery Flow Meters For Gas And Air

Compact Turbine Gas Meters For Flow Management Ultrasonic Flow Meters Ultrasonic Flow Meters USB RH & Temp. Data Logger USB RH & Temp. Data Logger USB RH & Temp. Data Logger Handheld Temp. Data Logger RoHS Portable!

Built-in lithium battery

TBX-D TBZ UX And UZ TRX And TRZ SYS-TH-L JS320-EX JHE-173 ExceLog It’s developed for controlling the gas consumption of each piece ofFor fuel gas, High performance, For Air (mainly the air in a General purpose ! Large LCD External sensor For cold-chain transporation 6 Channel, 2.83” touch panel equipment such as compact boilers and various industrial furnacesDust resistant & highly durable factory) or Nitrogen Range : -20~70°C, 0~100%RH Range : -40~85°C, 0~100%RH Range : -30~70°C, 0~100%RH Input (Excluding sensor) : The external power supply Corrects temperature and pressureRange : 0.12~6 ... 1.6~80 to 3~150 (m3/h) Range : ±0.6~35 to ±5~300 (m3/h) Memory : 86,000 log readings (max.) Memory : 43,000 log readings (max.) Memory : 43,000 log readings (max.) 4 x thermocouple (Type J, K, T, R, S, N, E) and Range : 4~30 m3/h to 12.5~150 m3/h Range : 6~60 m3/h to 30~300 m3/h Accuracy : ±2%RD, ±0.5%FS, ±1.5℃ ±10~500 to ±40~2000 (m3/h) Display : Built-in display shows current, Alarm Indicate : Alarm ring if user-defined Accuracy : ±0.5°C, ±3%rh 2 x 3-wire Pt100 inputs Flow Accuracy : ±1%FS Flow Accuracy : ±1%FS, ±3%RS Output : Unit pulse/ 4~20 mA / RS485 Accuracy : ±2.5% RS, ±2% RS min/max readings, alarm states max / min values are exceeded Resolution : ±0.1°C, ±0.1%rh Data Logging Interval : 1 to 86,400 seconds Output : Two systems of open-drain output Measurable Gases :Town gas, Butane , Output : Unit pulse/ 4~20 mA / RS485 PC Software : Free configuration, review and PC Software : Free software used to views Protection class : IP67 Max. SD Card Capacity : 32 GB SD or SDHC Measurable Gases : Town gas, LPG, nitrogen, etc. Propane, Nitrogen Working Pressure : 0~ <1MPa (Gauge pressure) Excel-export software graph, specific data and analysis PC Software : Free software used to views Signal Processing : Average, Min / Max, Power : 2×AAA Battery or mains powered Power supply : 9V DC graph, specific data and analysis standard deviation, 2-channel temp. difference Working Pressure : 100kpa Working Pressure : 980kpa or 350kpa Working Pressure : 100kPa (max.) Fluid Temperature : -10 ~ 60°C Mounting : Wall-mounted and Desk-top Interface : USB / RS232 / RS485 / RJ45(options) Power supply : 1/2 AA, 3.6V , Lithium Battery Power : Battery or mains powered Connection : Rc1½, Rc1¼, Rc2, JIS10K Connection : JIS 10K 40A flange, Fluid Temperature : -10~+60°C(No freezing) Connection : 25, 32, 40, 50, 65, 80A Certificate : CE approvals Size : 125×28×22mm Certificate :CE, RoHS approvals JIS 10K 50A flange, JIS 10K 80A flange Connection : RC ½, RC1, RC 1 ½ , RC2, JIS10K 100, 150, 200A

Compact - Mass Flow Meter Small Pipe - Mass Flow Meter Portable - Mass Flow Meter In-line Mass Flow Meter Wireless Pico-Humidity and Temperature Data Logger

Load the recorded data and perform other For General Purpose For Refrigerator, Cold-Chain Waterproof, IP64 operations via Bluetooth on iPhone or iPad ※ TSW-BLU is required for operating the logger from a computer (Option) 20m 20m 20m ‧Communication Method: Bluetooth Bluetooth Bluetooth BLE (Bluetooth Low Energy) MF4003 And MF4008 MF5000 Series MF5706 And MF5712 MF In-line ‧Power Supply : CR2032 button cell battery x 1 Designed for low gas flow in Highly sensitive; Low pressure Ultra low powe; Internal data for all purpose industrial gas TSW-02A TSW-02SP TSW-02WR fixed flow channel of 3 & 8 mm loss for reducing energy cost storage for additional data safety metering and control ‧Number of connections: Up to 32 units (recommended) Internal Sensor External sensor Internal Sensor, Waterproof Range : 0~2, 3, 4, 5 or 0~10, 20, 30, 40, 50 (SLPM) Range : 0.15-15 or 8-800 (SLPM) Range : 0~10, 25 or 0 ~200 (SLPM) Range : 0.01 ~ 65 Nm/sec ‧Memory : Range : -10~70°C, 0~100%RH Range : -40~125°C, 0~100%RH Range : -10~70°C, 0~100%RH Accuracy : ± (1.5 + 0.2 )FS Accuracy : ±(1.5+0.5FS)% Accuracy : ± ( +0.2.0 5FS) Accuracy : ±(1.5 + 0.5 FS)% Built-in memory. It Can logging for 1.9 Logging rate : 2sec, 10sec, 30sec, 1min, External Sensor : Sensor with 300mm FPC Protection class: IP64 Output : 0.5~4.5 V/ RS232, RS485 Output : 4~20mA, 0-5 V, Pluse / RS485 Output : RS485 (optional) Output : 4~20mA, 0-5 V, Pluse / RS485 year (logging rate:60min) 10min, 60min cable ,cable heat resistance is up to 150°C Logging rate: 2sec, 10sec, 30sec, Pressure Drop : 100 Pa, 600 Pa Measurable Gases : Air, CO2, N2, O2, Ar Measurable Gases : Air, CO2, N2, O2, Ar Measurable Gases : Air, CO2, N2, O2, Ar ‧Logger Data File : Max. Communication Range : approx. 20m Application : The sensor can paste on the 1min, 10min, 60min Measurable Gases : Air, N2O, CO2, N2, O2, Ar Working Pressure : 15 - 1.5MPa (max.) Working Pressure : ≤0.8 MPa (max.) Working Pressure : 15 - 1.5MPa (max.) The .csv files can be edited by iPhone (Without Obstacle) object to measure the surface temperature Applications : Application in greenhouse, Working Pressure : 0.5 MPa (max.) IP Protection Class : IP40 User Interface : miniUSB Data Storage : max. 3000 items E-mail to the computer Dimensions : 27×45×12mm Dimensions : 27×45×12mm (without sensor) plant factory, three warm, etc Working Teperature : -10~+55°C Ex Proof : Ex d IIC T4 (optional) Power Supply : 4 AA batteries or 6 ~ 15 Vdc Ex Proof : Ex d IIC T4 (optional) Applicable OS : iOS 8.1.3 or later ‧ Certificate : RoHS Dimensions : 41×61×14.5mm DN : DN3, DN8 (mm) Connection : NPT 1/8”, 1/4”, 3/8”, 1/2” ,3/4” Connection : NPT 1/4 or NPT 1/2 DN : DN25~DN100 (mm)

www.jetec.com.tw 25 www.jetec.com.tw 26 Factory Automation Control And Industrial Applications Digital Temperature Controller Factory Automation Control And Industrial Applications Digital Temperature Controller

Digital Temperature Controller/ Process Controllers

Plug-in Digital Digital Board Type Program Controller Program Controller Digital Temperature Controller Dual Channel Controller Temperature Controller Temperature Controller (up to 1485 patterns) (up to 64 patterns)

‧Various Functions ‧Easy to Use ‧Multiple Inputs ‧General Purpose Controller ‧Advanced and Multi-Loop controllers Selection table Model TTM-i4N TTM-000 TTM-000S TTM-200 TTM-509 TTM-04SP TTM-00B TTM-339 TTM-P4 / P9 Loop 1 1 1 1 2 1 1 1 1 Type Panel Panel Panel Panel Panel Plug-in Board Type Panel Panel K ● ● ● ● ● ● ● ● ● J ● ● ● ● ● ● ● ● ● T ● ● ● ● ● ● ● ● E ● ● ● R ● ● ● ● ● ● ● ● ● S ● ● ● ● ● ● ● ● B ● ● ● ● ● ● ● ● N ● ● ● ● ● ● ● Thermocouple U ● ● ● L ● ● ● ● ● ● Input type WRe5-26 PR40-20 ● ● ● PLII ● ● ● RTD Pt100, JPt100 ● ● ● ● ● ● ● ● Pt1000 ● current 4 to 20m ● ● ● ● ● ● 0 to 1VDC ● ● ● ● 0 to 5VDC ● ● ● ● ● voltage 1 to 5VDC ● ● ● ● ● ● 0 to 10VDC ● ● ● ● 0 to 10mVDC ● ● ● Potentiaonmeter(PV2) ● PID ● ● ● ● ● ● ● ● ● ON/OFF ● ● ● ● ● ● ● ● ● ● ● ● Control Method Output 1 & 2 Off Point ● ● Relay Contact ● ● ● ● ● ● ● ● ● SSR Drive Voltage ● ● ● ● ● ● ● ● ● Open collector ● ● ● Control Output Voltage ● Current ● ● ● ● ● ● RS232 ● RS485 TOHO protocol / ModBus TOHO protocol / ModBus TOHO protocol / ModBus TOHO protocol / ModBus TOHO protocol TOHO protocol / ModBus

Comm Loader Communication Loader Communication ● 24×48mm 1/32 DIN 48×48mm ● 1/16 DIN 1/16 DIN 1/16 DIN 1/16 DIN ● 96×48mm 1/8 DIN VERTICAL 1/8 DIN VERTICAL 1/8 DIN VERTICAL

Panel 48×96mm 1/8 DIN HORIZONTAL 1/8 DIN HORIZONTAL 72×72mm 3/16 DIN 3/16 DIN 3/16 DIN Dimensions 96×96mm 1/4 DIN 1/4 DIN 1/4 DIN 1/4 DIN 1/4 DIN ● 100 to 240V ●● ● ●●●●●

24VAC/DC ● Power Supply Number of Alarm 2 2 2 7 6 2 1 4 1 Sampling Cycle 250ms 500ms 250ms 200ms 50ms 250ms 200ms 200ms 500ms Operation Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Heating / Cooling Manual Control ● ● ● ● ● ● ● Blind Function ● ● ● ● ● ● ● Ramp Function ● ● ● Valve Function ●

Function Auxiliary Output ● ● ● DI Input ● ● ● ● ● ●

Standard / Option CT Input ● ● ● ● ● ● Transmission Output ● ● ● Remote SV Input ● Data Log SD Card

www.jetec.com.tw 27 www.jetec.com.tw 28 Factory Automation Control And Industrial Applications Infrared Temperature Sensor Factory Automation Control And Industrial Applications Infrared Temperature Sensor

Infrared Temperature Sensor For Special Applications General purpose. For small Focused optics for measuring For Thin Film Plastic (polyolefin, Application For Non-metalic or Painted Surfaces targets and fast measurements extremely small targets polyamide, nylon, PVC, etc.)

Low-cost / Fixed emissivity It's ideal if you aren't sure the Fully configurable sensor with For General Purpose emissivity of the target is high Modbus RTU communications

PM180 (optional) (optional) (optional)

Model PyroCube S and F PyroCube XSA And XSB PyroCube P Features Measured spot as small as 1.6 mm Measured spot as small as 0.7 mm Measured spot as small as 12 mm Model PyroCouple PyroEpsilon PyroBus Temperature Range 0°C to 500°C, 50°C to 500°C 0°C to 500°C, 50°C to 500°C 120°C to 350°C Features Simple, one-piece pyrometer With emissivity adjuster(optional) Connect to an Modbus PLC or PM180 Output Signal 0-20 mA, 4-20 mA, mV/°C, RS232 0-20 mA, 4-20 mA、 mV/°C, RS232 0-20 mA, 4-20 mA、 mV/°C, RS232 Options : 0-1V, 0-5V, 0-10V Options : 0-1V, 0-5V, 0-10V Options : 0-1V, 0-5V, 0-10V Temperature Range -20°C to 500°C -20°C to 500°C -20°C to 500°C Emissivity 0.3 to 1.0 0.3 to 1.0 0.3 to 1.0 Output Signal 4-20mA / 0-50mV / T, J, K Type 4-20mA RS485 Modbus RTU Spectral Range WRNjP WRNjP NjP Emissivity )L[HGDW Variable 0.2-1.0 via 4-20mA input Adjustable 0.2-1.0 via RS485 Modbus Measurement Distance 150mm, 200mm, 300mm (max.) 100mm, 300mm (max.) 200mm (max.) Spectral Range WRNjP WRNjP WRNjP Focal Spot Diameter 1.6mm, 3mm, 5.5mm 0.7mm, 1mm 12mm Response Time, t90 PV UHVSRQVH PV UHVSRQVH PV UHVSRQVH Response Time, t90 1 ms, 10 ms (Adjustable up to 5s) 1 ms, 10 ms (Adjustable up to 5s) 10 ms Optics 2:1, 15:1, 30:1 ,Ø5mm @ 100mm 2:1, 15:1, 30:1 ,Ø5mm @ 100mm 2:1, 15:1, 30:1 ,Ø5mm @ 100mm Dimensions 18(dia.) x 103(L) mm 18(dia.) x 103(L) mm 18(dia.) x 103(L) mm Application For Metals or Glasses Surfaces

PC configurable, with current It ‘s ideal for use in benchtop, Application for the high PC Configurable Pyrometer for Two-part Pyrometer for High Fiber Optic Pyrometer for Harsh output lab & education applications temperature (up to 180°C) Metals and High Temp. Targets Temperature Targets and Metals Applications

(Standard)

(optional)

Model PyroUSB PyroMini USB PyroMini Model PyroUSB 2.2 PyroMini 2.2 FibreMini Features Simple, one-piece pyrometer For PC based data acquisition Touch screen interface (optional) Features Can measure through glass Can measure through glass Can measure through glass

Temperature Range -40°C to 1000°C -20°C to 1000°C -20°C to 1000°C Temperature Range 45°C to 300°C ... 450°C to 2000°C 100°C to 400°C ... 450°C to 2000°C 250°C to 1000°C ... 450°C to 2000°C Output Signal 4-20mA and USB USB 4-20 mA or RS485 Modbus Output Signal 4-20mA or 0-20mA and USB 4-20 mA or RS485 Modbus 4-20 mA or RS485 Modbus Emissivity WRNjP 0.2 to 1.0 0.20 to 1.00 Emissivity WRNjP Adjustable, 0.10 to 1.00 Adjustable, 0.10 to 1.00 Spectral Range 0.1 to 1.0 WRNjP WRNjP Spectral Range 0.1 to 1.0 WRNjP WRNjP Response Time, t90 PV UHVSRQVH PV UHVSRQVH PV UHVSRQVH Response Time, t90 •PV UHVSRQVH •PV UHVSRQVH •PV UHVSRQVH Optics 15:1, 30:1 2:1, 20:1 2:1, 15:1, 20:1, 30:1 ,Ø5mm @ 100mm Optics 15:1, 25:1, 75:1, ø7.5mm @ 500mm 15:1, 25:1, 75:1, ø7.5mm @ 500mm 30:1 ,75:1 Dimensions 25(dia.) x 106.5(L) mm 18(dia.) x 45(L) mm 18(dia.) x 45(L) mm Dimensions 25(dia.) x 106.5(L) mm 18(dia.) x 45(L) mm 12(dia.) x 48(L) mm

Short-wavelength sensors for Ideal for annealing Suitable for high-temperature Multi-channel miniature Compatible with NFC-equipped Certified Intrinsically Safe for measuring metals glass melting pyrometer system Android devices explosive site

(optional)

(optional) (optional) (optional)

Model PyroCube MA And MB PyroCube G PyroCube GH Model PyroMini BUS PyroNFC ExTemp Features Metals, low temperature Smartphone-configurable pyrometer ATEX, IECEx or TIIS Certified Features High Ambient Temperature 120°C Smartphone-configurable pyrometer ATEX, IECEx or TIIS Certified Temperature Range 100°C - 600°C 100°C - 1200°C 100°C - 2400°C Temperature Range -20°C to 1000°C 0 to 1000°C -20°C to 500°C Output Signal 0-20 mA, 4-20 mA, mV/°C, RS232 0-20 mA, 4-20 mA, mV/°C, RS232 0-20 mA, 4-20 mA, mV/°C, RS232 Output Signal RS485 Modbus RTU 0-5 V or 0-10V or K Type RS485 Modbus RTU Options : 0-1V, 0-5V, 0-10V Options : 0-1V, 0-5V, 0-10V Options : 0-1V, 0-5V, 0-10V Emissivity 0.2 to 1.0 0.2 to 1.0 Adjustable 0.2-1.0 via RS485 Modbus Spectral Range 2.2 μm 5 μm 5 μm Spectral Range WRNjP WRNjP WRNjP Emissivity 0.05 to 1.0 Adjustable, 0.3 to 1.0 Adjustable, 0.3 to 1.0 Response Time, t90 PV UHVSRQVH PV UHVSRQVH PV UHVSRQVH Measurement Distance 100mm, 200mm, 400mm, 500mm (max.) 500mm, 1000mm (max.) 300mm, 500mm (max.) Optics 2:1, 20:1 15:1 2:1, 15:1, 30:1 ,Ø5mm @ 100mm Focal Spot Diameter 1mm, 3mm, 3.5mm, 11mm 7mm, 20mm 2.2mm, 4.5mm Dimensions 18(dia.) x 45(L) mm 31(dia.) [ / PP 18(dia.) x 103(L) mm Response Time, t90 1 ms 50 ms 10 ms

www.jetec.com.tw  www.jetec.com.tw 30 Factory Automation Control And Industrial Applications Gas Detector HVAC Applications Differential Pressure Transmitter / Pressure Transmitter

Portable Gas Detector Differential Pressure Transmitters For Air These Portable Gas Detector are capable of detecting many toxic and combustible gases making them ideal The applications of Differential Pressure Transmitters include clean / isolation room control, air handling unit for those working in harsh environments. control and filter monitoring.

Single Gas Detector 4 in 1 Gas Detector Pump Typee GasGas DetectorDe Pump Type GasGas DetectorDet General Purpose Voltage Output High Pressure High Pressure

KGD-SP2 CGD-1200H-M4 CGP-2000 CGP-2000-M PEL PEL-1000 PEL-2500 PEL-8K The gas concentration unit PPM Rugged and reliable, Simple Internal sampling pump, Multi-Gas, Internal sampling Range : 0...100, 0...200, 0...500, 0...1000, Range : 0...500 or 0...1000 Pa Range : 0...100, 0...200, 0...500, 0...1000, Range : 0...1000, 0...1500, 0...2000, 0...2500, & mg/m3 can be shifted quickly operation for ease of use fast response pump, fast response ±50, ±100, ±250 or ±500 Pa Accuracy :±3 Pa ±1% of reading 0...1500, 0...2000, 0...2500 or ±100 Pa 0...3000, 0...4000, 0...5000 or 0...8000 Pa Measured Gas And Range (optional) : Measured Gas And Range : Measured Gas And Range (optional) : Measured Gas And Range (optional) : Accuracy :±0.5 Pa ±1% of reading(25°C) Time constant :3 s Accuracy : ±3 Pa ±1% of reading Accuracy : < ±10 Pa ±1% of reading (25°C) O2 : 0~30%VOL / CO : 0~500ppm O2 : 0-1000ppm O3 : 0~10ppm / CO : 0-1000ppm 2 in 1 : NH3 / H2S Time constant :2 s or *8 s Ambient temperature 0~50: °C Time constant :2 s or *8 s Time constant :2 s or *8 s SO2 : 0~20ppm / H2 : 0~1000ppm CO : 0-100ppm CH2O : 0-30ppm/CH3OH : 0~20ppm 0~1000ppm / 0-1000 Ambient temperature 0~45: °C IP Protection Class :IP54 Ambient temperature 0~45: °C Ambient temperature 0~45: °C H2S : 0~100ppm/CI2 : 0~20ppm H2S : 0-30%VOL SO2 : 0-10ppm to 0-5000ppm 3 in 1 : CO / CO2 / CH4 IP Protection Class :IP54 Supply : 24 Vac/dc, < 1 VA IP Protection Class :IP54 IP Protection Class :IP54 NH3 : 0~100ppm/NO2 : 0~20ppm Combustible gase : 0-100%LEL TVOC : 0-1ppm to 0-6000ppm 0-1000ppm / 0-2000ppm / 0-5%VOL Supply : 24 Vac/dc, < 2 VA Supply : 24 Vac/dc, < 2 VA Supply : 24 Vac/dc, < 2 VA Measurement Method : Electrochemical Alarm : Buzzer / Light C7H8 : 0-1ppm to 0-6000ppm 4 in 1 : CO / O2 / H2S / EX Alarm : Buzzer 90dB / RED LED / Vibration Explosion Proof : Ex ia IICT4 NH3 : 0~200ppm 0-1000ppm / 0-1000ppm / 0-100ppm / 0-100%LEL Explosion Proof : Ex ia IIC T4 Protection class : IP66 CO2 : 0-1000, 2000, 5000, 10000, 50000ppm Sampling Method : Pumping suction Selection Table Protection class : IP67 Power : 3.7V rechargeable lithium battery 0-10, 20, 50, 100 %VOL (options) Alarm : Buzzer / Light / Vibration Measuring ranges Zeroing Outputs Event Log : Save the latest 20 data Unit : ppm, mg/m3, %VOL, %LEL Alarm : Buzzer / Light / Vibration Explosion Proof : Ex ia IICT4 Power : Lithuim 1/2 AA battery, 3.6V/1.2Ah (The gas concentration unit PPM and mg/m3 can Explosion Proof : Ex ia IICT4 Protection class : IP66 be shifted quickly.) Protection class : IP66 Power : 3.7V rechargeable lithium battery 1) 0...8000 Pa 4...20 mA Modbus Flow linear Automatic 0...10 V Display ±100 Pa 0...2500 Pa 0...3000 Pa ±250 Pa ±500 Pa 0...100 Pa 0...1000 Pa 0...2000 Pa 0...1500 Pa Custom Manual 0...200 Pa 0...500 Pa 0...4000 Pa 0...5000 Pa 0...6000 Pa 0...7000 Pa 0...9000 Pa Model ±50 Pa Fixed Gas Detector PEL Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʉ Ʉ

These Fixed Gas Detector installed in a place where potential gas hazard exists to measure oxygen, toxic gas PEL 2500 Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʉ Ʌ Ʉ and combustible gas, in order to prevent any accidents in advance. PEL 8K Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʌ Ʉ Ʌ Ʉ

Diffusion Type - Gas Detector Diffusion Type - Gas Detector Suction Type - Gas Detector Smoke detectors PEL 1000 Ʌ Ʌ Ʌ Ʌ Ʌ Ʉ Ʉ

● : Standard ○ : Optional 1) The custom pressure range can be adjusted with ML-SER tool (or via Modbus) within the transmitter’s normal pressure ranges.

(Differential) Pressure Transmitters For Water It's designed for detecting water / glycol or other fluid pressures in heating and cooling systems KGD-SP2 JDA-50 JDA-750 KRM Sries Easy magnetic bar operation; LCD display with Back Light; It is effective gas sampling It’s designed for smoke Differential Pressure Transmitter Pressure Transmitter digital LCD with a blue backlight multi signal output especially for closed area detection in ventilation ducts

Measured Gas :CH 4, O2, CO, SO2, H2S, NH3, H2 Measured Gas :Refer to the target gas list Measured Gas :Refer to the target gas list Probe : 160 mm Measurement Range please refer to the target gas list Accuracy : ≤2% /full scale Accuracy : ≤2% /full scale Sensor : Optical RM3.3 (ALK-E) Accuracy : ±3%/Full scale Output : 4-20mA, RS485(option) Memory : 4,000 records Output Alarm : Output : 4-20mA , RS-485(Option), Relay Alarm : SPST 2 step relay contacts (AL1/AL2). Sample gas volume : 1.0 ~ 2.5 Liter/min 250 Vac, / 24 Vdc, 8 A, change-over contact Alarm level : Alarm value(1,2,3 alarm) Density Indication : LCD - PPM, %LEL, or % Output : 4-20mA, RS485(option) 250 Vac, / 24 Vdc, 8 A, NC contact Parameter Control: Front 3 magnetic switch Response Time: <20 seconds, 90%/full scale Alarm : SPST 2 step relay contacts (AL1/AL2). Output (contamination) : Materianl : Aluminium, Stainless steel(304) Materianl : Polycarbonate Alarm Delay Time: 0~99 s with user adjustable 250 Vac, / 24 Vdc, 6 A, NC contact VPEL 1.0/2.5 VPEL 4.0/6.0 VPL 16 VPL 60 Range : 0~1.0 bar / 0~2.5 bar (= L/H) Range : 0~4.0 bar / 0~6.0 bar (= L/H) Range : 0~2.5, 0~6.0, 0~10, 0~16 (bar) Range : 0~16, 0~25, 0~40, 0~60 (bar) Target gas list Output : 0...10 Vdc / 4…20 mA Output : 0...10 Vdc / 4…20 mA AsH3 0~1.00 ppm CO2 0~5000ppm F2 0~10.0 ppm HCI 0~10.0 ppm PH3 0~1.00 ppm SF4 0~9.00 ppm Measuring Error : < 2.5 % of full scale Inaccuracy : < 0.1 bar Inaccuracy : < ±0.5 bar AsCI3 0~1.00 ppm CO2 0~5.00% GeH4 0~1.00 ppm l2 0~10.0 ppm PCI3 0~15.0 ppm SF6 0~8000 ppm Temperature Drifting : < 0.5 % of full scale / 10 K Long term stability : < 0.2 bar / year Long term stability : <± 0.3 bar / year AsF3 0~10.0 ppm CO2 0~100% GeCI4 0~10.0 ppm NO 0~100 ppm POCI3 0~10.0 ppm SnBr4 0~10.0 ppm Zero Point Setting : manual, by a push button Ambient Temperature : 0~60 °C AsF5 0~10.0 ppm CO 0~500 ppm H2 0~2000 ppm NO2 0~20.0 ppm S2CI2 0~10.0 ppm SnCI4 0~30.0 ppm Long term stability : ± 0.03 bar/year Allowed Medium Temperature : 0~85°C BCI3 0~15.0 ppm COCI2 0~5.00 ppm H2 0~1000 ppm1) NH3 0~100 ppm Si2H2 0~10.0 ppm SnF4 0~10.0 ppm BBr3 0~15.0 ppm CCI4 0~30.0 ppm H2 0~100% VOL N2H4 0~10.0 ppm SiCI4 0~10.0 ppm TiCl4 0~10.0 ppm Ambient Temperature : -20~70°C Max. Overpressure : 50 bar Max. Overpressure : 120 bar BF3 0~10.0 ppm CI2 0~10.0 ppm H2 0~100% LEL O2 0~10000 ppm SiH4 0~20.0 ppm TEOS 0~40 ppm Allowed Medium Temperature : -20~100°C Max. Negative Pressure : 1 bar B2H6 0~1.00 ppm CH3OH 0~500 ppm H2S 0~100 ppm O2 0~25% vol SO2 0~20.0 ppm VOCs 0~1000 ppm Maximum Static Operation Pressure : 16 bar Mounting : R ½” Br2 0~1.00 ppm CH4 0~100% LEL H2O2 0~100 ppm O2 0~30% vol SO2F2 0~10.0 ppm WF6 0~12.0 ppm H2SiCl2 0~10.0 ppm O3 0~1.00 ppm IP Protection Class : IP54 IP Protection Class : IP54 1) Only for KGD-SP2 Supply : 24 Vdc, 45 mA (15…32Vdc) Supply : 24 Vdc, 1VA

www.jetec.com.tw 31 www.jetec.com.tw 32 HVAC Applications Air Flow / Wind And Rain Sensor HVAC Applications / Agriculture Weather Sensors Rain And Precipitation Sensor

Air Velocity And Air Flow Transmitter Water Leakage Monitoring They are widely used in semiconductor production equipment, clean rooms and building automation systems.

Aiv Velocity Transmitter Air Flow Transmitter Air Flow Probe Water Leakage Relay Water Leak Sensors will be used with VVK 2

* Resistance of a dry sensor about 300 kΩ Water Leak Sensing Band VVN 1 VVN1 with a 2m ribbon and 2m cable, installation on floor or piping surface.

IVL IML PP-PK And PP-SK VVK 2 Output can be selected at For detecting and controlling The PP air flow volume probes are designed for air flow VVK 2 monitors the resistance Water Leak Sensor Water Leak Sensing Band the commissioning. With a air flow in air m³/s, m³/h, l/s, volume measurement together with the IML air volume of the sensors. When the sensor VVA 1 VVN 2 100 and 400 mm long stem. Pa handling units and rooms. transmitter. It’s also easy to install to the existing ducts. becomes wet the resistance decreases and the alarm relay VVA 2 with a wiring case, installation on VVN2 with a 1m ribbon and 2m cable, Air Velocity Range: 0~2, 0~10, 0~20 (m/s) Air Volume Range :0~1000 Pa , 0~2000 Pa PP-PK : Round ducts PP-SK : Sectangular ducts will be activated. Also the sensor the floor surface installation on floor or piping surface. Temperature Range: 0~50 °C 0~5000 Pa, 0~7000 Pa Duct Diameter :100, 125, 160, 200, 250, Duct Width :200, 250, 300, 350, 400, 450, circuit will be monitored. Output : 0-10 V, 4-20mA Output : 2 × 0-10V, RS485(options) 300, 315, 355, 400, 450, 500, 550, 600, 630 500, 550, 600, 650, 700, 750, 800, 850, 900 Velocity Deviation : Input : 0-10V (air volume set point ) 700, 800, 1000mm 950, 1000, 1050, 1100, 1150, 1200 mm Measurement Method : 24 Vac/dc, 2 VA IVL 02 : < 0.1 m/s ±7 % from reading Accuracy : ±1 Pa + ±1% of reading (25 °C) Operating Temperature: 5~95 °C Duct height And Number of PP-SK Probes : Alarm Limits : H< 80 kΩ Water Leak Sensor Water Leak Sensing Band IVL 10 : < 5 m/s ±7 % from reading Output time constant : 1~20 s Accuracy (air speed > 1 m/s) :±2 % 150...300 mm - 1 L < 10 kΩ VVA 2 VVA 3 IVL 20 : < 1 m/s ±7 % from reading Maximum Allowed Overpressure : 25 kPa Connection : with Ø 6/4 mm hoses 350...600 mm - 2 Output : potential free contact 60 Vdc, 2 A VVA 2 with a 2 m cable, installation on The sensor includes adhesive tape and Mounting : by adjustable flange Protection class : IP54 700...900 mm - 3 Protection class : IP67 the floor surface 2 m cable. 25 x 200mm with tape fixing, IP Protection Class : IP54 (transmitter) Pressure Connection : With Ø 6/4 mm hoses 1000...1200 mm - 4 Sensor fault alarm : > 330 kΩ 2m cable, installation on floor surface . Dimensions : 53(W) x 90(H) x 61(D) mm Air Flow Quick Application Guide Air Flow Measurement Model Application PEL 2500+ IML+ IVL PEL 2500 IML PP-PK/SK PP-PK/SK The low cost high quality rain gauge ideal for small weather stations, irrigation and soil moisture management, Fan Flow (Fan withThe fan K-value is known Ʌ water treatment plants, agriculture, forestry, meteorological institutes, research institutes & consumer purposes. measuring inlets) The fan K-value is unknown Ʌ Customer’s probe for which the K-value is known Ʌ Ʌ The Rain Gague with small patented self-emptying tipping bucket, advantages in: Flow in duct Customer’s probe for which the K-value is unknown Probe not available (air velocity and temperature measurement) Ʌ ‧More accurate measurements. Probe not available (air volume measurement) ɅɅɅ‧Only one adjustment screw which makes it easy to recalibrate. ‧Bucket made in POM - The dust and dirt not stick so easily on the spoon and maximize water release. ‧Minimal maintenance - Outer shell is made from STYROSUN which makes the surface easy to clean.

Wind And Rain Sensors Small And Tower Rain Gauge Professional Rain Gauge Meteorological Rain Gauge Meteorological Snow & Rain Gauge These sensors is designed for detecting and monitoring rain, wind speed and direction in HVAC applications. RoHS RoHS RoHS RoHS

Rain Sensor Wind Speed Detector Ultrasonic Wind Sensor Wind Sensor

WMO compliant WMO compliant

JRS-054 And JRT-074 JRP-023 JRM-002 JRS-042 Orifice : 200cm2 / Total height : 225 mm Orifice : 50 cm2 / Total height : 10.0 cm Orifice : 200cm2 / Total height : 170 mm Orifice : 200cm2 / Total height : 290 mm Built-in 2 seperate heated rooms Accuracy : ±2% Accuracy : ±2% Accuracy : ±2% Accuracy : ±2% SA10 TUNA 20 UV7-LY7LY VS 3000 Range : weak rain approx. 1 V, < 0.5 mm/h Wind Range :0...20 m/s Direction Range :0...359 ° Direction Range :0...359 ° Specitications normal rain approx. 2~3 V Temperature Range :-50...50 °C Speed Range :0...15 m/s / 0...30 m/s Speed Range :0...35 m/s Capacity per minute with 12 tips Typical switching times heavy rain approx. 3~10 V Output : 0-10V, 4-20mA Output : 3 x 0...10 Vdc, RS232 NMEA0183® Output : 2 x 0...10 Vdc, RS232 NMEA0183® Model Output : 0-10V Deviation, wind speed< : 20% of the measurement Time Constant : 1, 2, 4, 8, 16 s Maximum Wind Speed :50 m / s Resolution(mm) Capacity(mm) Normally closed Normally open Relay contact:normally open contact Deviation, temperature< : 0.5 °C Direction Accuracy :±1° Accuracy :±1° , ±1 m/s JRS-054, JRT-074 1.00 12 Heating :built-in Time constant :8s ( 63%) Speed Accuracy :±0.05 m/s Diameter Of Pole :< Ø 50 mm 0.10 1.2 PV ı P6 PV ı P6 Mouting :by a band to a mast (Ø25…60 mm) Operating temperature -50~50: °C IP Protection Class :IP65 IP Protection Class :IP65 JRP-023 0.20 2.4 PV ı P6 PV ı P6 or by screws on the wall Mouting :Wall mounting with screws Ambient temperature -15...55: °C Operating temperature -35...70: °C JRS-042 0.25 3.0 PV ı P6 PV ı P6 IP Protection Class :IP54 IP Protection Class :IP54 Cable : 25 m Cable : 10 m JRM-002 0.50 6.0 PV ı P6 PV ı P6 σ = Standard deviation Filter design: Max 200msec recommended

www.jetec.com.tw 33 www.jetec.com.tw 34 Agriculture Weather Sensors Wind Speed And Wind Direction Sensor Agriculture Weather Sensors Solar Radiation Sensor

Wind Speed And Wind Direction Sensor Pyranometer Application for the wind speed monitor in engineering machinery leasing, hoist, factory, electric power, are sensors that measure global shortwave radiation. Applications include shortwave radiation port machinery, mine industry, photovoltaic fields. measurement in agricultural, ecological, and hydrological weather networks and solar panel arrays.

Handheld Aviation plug - Wind Speed Wind Direction Sensor Wind Data LoggeLoggerr Silicon-cell Pyranometer Smart Pyranometer Thermopile Pyranometer Pyranometer Meter RoHS RoHS RoHS RoHS

JSP-610

JSP-420 JMP-200 Power 3 AA batteries JSP-421 JSP-510 JMP-100

JWH-61 CWS-013A CWS-023A JWS Log JSP-110 : Self-Powered Pyranometer JSP-420 : USB Output JSP-510 : Upward-looking JSP-100 : Integral Sensor with Handheld Meter JSP-212 : Amplified 0-2.5 Volt JSP-421 : SDI-12 Output JSP-610 : Downward-looking JSP-212 : Separate Sensor with Handheld Meter Automatic display illumination Multi-level surge protection Turndown ratio 50:1, Negligible On-site and in real time ! USB JSP-214 : Amplified 4-20 Milliamp and temperature design, Strong wind load ability pressure drop, High durability port provides fast downloads JSP-215 : Amplified 0-0.5 Volt Measurement range : 1.0~40 m/s Measurement range : 0.5~60m/s Measurement range : 0°~360° Wind Speed JSP-230 : All-Season Pyranometer Temperature Range : -20~60°C Accuracy : ±0.5 m/s (<5m/s), Accuracy : ±2° Range : 0 ~67 m/s (150 Mph) Accuracy : ±4%(wind), ±1°C(Temperature) Measuring value±3% (≧5 m/s) Output : 4~20mA Accuracy : ±2%, ±22.5° Spectral Resolution : 0.1 unit (< 9.9) , 1unit (>10) Output : 4~20mA Resolution : 0.35° Threshold : 45m/sec. (1 Mph) Type Output Power Supply Sensitivity Range Unit : m/s, Km/h, Knots, mph, Bft / °C, °F Resolution : 0.1m/s Threshold : ≤0.5m/s Wind Diredtion -2 -2

Averaging period : selectable 0, 5, 10, 20, 40 s Threshold : ≤0.5m/s Wind load : >70 m/s Range : 360° – no deadband -2 -2 -2 -2 -2 Battery : User replaceable 3V lithium battery Wind load : >70 m/s IP Protection Class : IP65 Accuracy : ±22.5° type CR2032 Cup material : PC+ABS Vane material: PC+ABS Threshold: .9 m/sec. (2 mph) at a 10° detection Model

Self-Powered Ultrasonic Wind SensorUltrasonic Wind Sensor Wireless Anemometer Wireless Anemometer 0.2 mV per W m 0.013 mA per W m 4.0 mV per W m Response Time Heater Data Log 0.057 mV per W m Field of View 2.0 mV per W m 0 to 350 mV 0 to 2.5 V 4 to 20 mA 0 to 5.0 V SDI-12 Digital 360 to 1120 nm 385 to 2105 nm 295 to 2685 nm Self-Powered 2.5 to 24V DC 5 to 36V DC 5 to 24V DC 12V DC 3V Battery(CR2320) 0.2 mV per W m 0.15 mV per W m USB Output Thermopile Silicon-cell JSP-110 Ʌ Ʌ Ʌ Ʌ Ʌ 180° <1ms JSP-212 Ʌ Ʌ Ʌ Ʌ Ʌ 180° <1ms JSP-214 Ʌ Ʌ Ʌ Ʌ Ʌ 180° <1ms JSP-215 Ʌ Ʌ Ʌ Ʌ Ʌ 180° <1ms Powered Byby JSQ-230 Ʌ Ʌ Ʌ Ʌ Ʌ 180° <1ms Solar Panel JSP-420 Ʌ Ʌ Ʌ 180° 1s Ʌ JSP-421 Ʌ Ʌ Ʌ 180° 0.6s FUW-DZP FUW-CV7V JWR-3B SW-B/S And SW-B/SD JSP-510 Ʌ Ʌ Ʌ 180° <0.5s Ʌ It’s well suited to remote installationsFor motorboats and terrestrial Long range - distance between Wireless link to smart phones JSP-610 Ʌ Ʌ Ʌ 150° <0.5s Ʌ where power consumption matters, Easy mounting sensor and display unit up to 400mand tablets via free APP JMP-100 Ʌ Ʌ Ʌ 180° <1ms Ʌ Wind Module sensitivity : 0.12 m/s Wind Module Dynamic : 0.8~50.0 m/s Measurement range : 0.6~50 m/s Transmission Distance: up to 90m JMP-200 Ʌ Ʌ Ʌ 180° <1ms Ʌ Wind Module Dynamic : 0.12 to 40 m/s Wind module resolution : 0.05m/s Temperature Range : -30~60°C Wind Speed Range : 0.6~50 m/s Wind Module resolution : 0.05 m/s Direction sensitivity : ±1.5° Accuracy : ±3%(wind), ±1°C(Temperature) Wind Direction Range : 0~359° Direction sensitivity : ±1.5° Direction Resolution : 1° Resolution : 0.1 unit (< 9.9) , 1unit (>10) Accuracy : ±3% (wind speed) / ±2.5°(wind direction) Direction Resolution : 1°(9 bits) Output : 4~20mA Unit : m/s, Km/h, Knots, mph, Bft / °C, °F Resolution : 0.1m/s(wind speed) / 1°(wind Direction) UV Sensors Output : WA: 25KΩ, 5V max, Operating Temperature : -15°C~55°C Data transmission : every 2 senconds Temperature Range : -30°C~60 °C Applications include: UV radiation measurement in outdoor environments (sensor isn’t recommended for long-term WS: Pulse open collector 10 mA max Mounting type : Vertical mast Battery : 1×3.6V AA Lithium battery (sensor) Data transmission : every 1 senconds Connection : RJ11 Diameter : 16mm 2×1.5V AA (Display unit) Battery : 1×3.6V AA Lithium battery continuous outdoor deployment), laboratory use with artificial light sources, and monitoring the filtering ability and stability of various materials. Wireless Wind Logger Wireless Anemometer Wireless Anemometer USB Wireless Wind Sensor Self-cleaning Housing UV Sensor Integral Sensor - UV Meter Separate Sensor - UV Meter

RoHS RoHS RoHS The patented domed shaped sensor head facilitates runoff of dew and rain, helping to keep the detector clean and minimizing errors caused by dust blocking the radiation JWS-L401 And JWSD-L401N SWS-410 And SWS-410BAT SWS-301 SWW110USB JSU-100 JMU-100 JMU-200 path. Sensors are housed in a Easy-to-use solution on for Alarm and pre-alarm warning 3 Programable alarm relay With USB output provides reading rugged anodized aluminum Measures combined UVA & It has a sample and log mode It has a sample and log mode wind site evalua on lights with sound alarm outputs data from sensors on personal PC UVB radiation and can store up to 99 averages and can store up to 99 averages body and electronics are fully Transmission Distance: 250m or 1200m Transmission Distance: 500m or 1300m Transmission Distance: 400m or 1km Transmission Distance: 250m or 1300m Spectral Range : 250 nm to 400 nm Spectral Range : 250 nm to 400 nm Spectral Range : 250 nm to 400 nm potted. Wind Speed Range : 0.6~50 m/s Wind Speed Range : 0.6~50 m/s Wind Speed Range : 0.6~50 m/s (3-5km with Yagi antennna) Field of View : 180° Field of View : 180° Field of View : 180° Wind Direction Range : 0~359° Accuracy : ±3% Accuracy : ±3% Wind Speed Range : 0.6~50 m/s Response Time : Less than 1 ms Response Time : Less than 1 ms Response Time : Less than 1 ms Temperature Range : -40°C~60 °C Resolution : 0.1m/s Resolution : 0.1m/s Wind Direction Range : 0~359° Output : 0-35mV Calibration Uncertainty : ± 10 % Calibration Uncertainty : ± 10 % Accuracy : ±3% (wind speed) / ±2.5°(wind direction) Data transmission : every 2 senconds Data transmission : every 2 senconds Temperature Range : -30°C~60 °C Calibration Uncertainty : ± 10 % Cosine Response : ± 10 % at 75° zenith angle Cosine Response : ± 10 % at 75° zenith angle Resolution : 0.1m/s(wind speed) / 1°(wind Direction) Averaging period : selectable 2 s, 10 s, 30 s Averaging period : selectable 2 s, 10 s, 30 s Accuracy : ±3% (wind speed) / ±2.5°(wind direction) Sensitivity : 0.2 mV / μmol-2 m s-1, 0.58 mV / W m-2 Operating Environment : 0 to 50 °C Operating Environment : 0 to 50 °C Battery : 1×3.6V AA Lithium battery (Sensor) Receiver Power : 1.5VAA Battery or 12~24VDC Power : 12~24VDC (Receiver) Resolution : 0.1m/s(wind speed) / 1°(wind Direction) Cosine Response : ± 10 % at 75° zenith angle Power : 3V Battery(CR2320) Cable : 2 m of shielded 2×1.5V AA (Display unit) Sensor Power : 1×3.6V AA Lithium battery 1×3.6V AA Lithium battery (Sensor) Sensor Battery : 1×3.6V AA Lithium battery Operating Environment : -40 to 70 °C Power : 3V Battery(CR2320)

www.jetec.com.tw 35 www.jetec.com.tw 36 Agriculture Weather Sensors Solar Radiation Sensor Agriculture Weather Sensors Solar Radiation Sensor

Quantum Sensor Typical applications include PPFD (Photosynthetic Photon Flux Density) measurement over plant canopies in outdoor Net radiation is a key variable in the surface energy balance and influences turbulent fluxes, including evapotrans- environments, greenhouses, and growth chambers. The sensors can be submerged in water up to depths of 30 m. It's piration. Applications include measurements on flux towers and weather stations. also used to measure PAR / PPFD in aquatic environments, including salt water aquariums where corals are grown. Four-component Net Radiometer Pyranometer

Original Quantum Sensor Line Quantum Sensorensor Smart Quantum Sensor Full Spectrum Quantum Sensor RoHS RoHS RoHS RoHS RoHS RoHS RoHS Upward-looking Upward-looking Pyrgeometer Pyranometer

JSQ-500 Downward-looking Downward-looking Pyrgeometer Pyranometer JSQ-520 JSN-500 JSL-500 Series JSP-500 Series Four-component measurement of net radiationSensitivity : 0.12 mV per W m-2 Sensitivity : 0.057 mV per W m-2 (upward-looking); The sensors has been calibrated forThe line quantum sensors measureIt’s calibrated independently It’s increases the accuracy of with black-body pyranometers and pyrgeometersCalibration Factor : 8.5 W m-2 per mV 0.15 mV per W m-2 (downward-looking); use in sunlight or with electric lightsa spatial average of PAR for sunlight and electric light LED measurements. it's ideal Input Voltage Range : 5 to 16 V DC Calibration Uncertainty : ± 5 % Calibration Factor : 17.5 W m-2 per mV (upward-looking); JSQ-110 / JSQ-120 : Self-powered JSQ-313 / JSQ-323JSQ-32 : with 3 Sensors to improve measurement for use with both natural and accuracy electric light sources Response Time (using SDI-12 Protocol) : Measurement Range : 200 to 200 W m-2 (net longwave irradiance) 6.7 W m-2 per mV (downward-looking) JSQ-212 / JSQ-222 : 0 to 2.5 V JSQ-316 / JSQ-326 : with 6 Sensors 1 s (SDI-12 data transfer rate; detector response times are 0.5 sec) Response Time : Less than 0.5 s Output Range : 0 to 114 mV (upward-looking); JSQ-214 / JSQ-224 : 4 to 20 mA JSQ-311 / JSQ-321 : with 10 Sensors JSP-420 : USB Output JSQ-500 : 0 to 40 mV Output Operating Environment : -50 to 80 C; 0 to 100% relative humidity Spectral Range : 5 to 30 μm (50 % points) 0 to 300 mV (downward-looking) JSQ-215 / JSQ-225 : 0 to 5.0 V JSQ-520 : USB Output Cable : M8 connector (IP67 rating) to interface to sensor housing Zero Offset B : Less than 5 W m-2 Measurement Range : 0 to 2000 W m-2 (net shortwave irradiance)

Quantum Meter Quantum Meter With Line SensorUnderwater Quantum Meter Full-spectrum Quantum Meter RoHS RoHS RoHS RoHS Spectroradiometer Typical Applications : spectral output (energy flux density, photon flux density, or illuminance) of different radiation sources (often for plant or human lighting), reflectance and transmittance measurements of natural and synthetic surfaces and materials (often plant leaves and canopies), and absorptance measurements of chemical samples.

Field Spectroradiometers Lab Spectroradiometers The hand-held meter can displaysSeparated sensor bar with3, 6 or 10 It’s preprogrammed with the immersionIt’s increases the accuracy of Type All measurement components contained in a 3RZHUHG«WKURXJK«WKH«86%«SRUW«RQ«D«FRPSXWHU«WR«DOORZ«PRELOH«¿HOG« and stores measurements sensors connected to a hand-heldeffect meter correction factor, so no post-LED measurements durable, weatherproof housing measurements JMQ-100 : Integral Sensor with Handheld Meter JMQ-301 : Line Quantum with 10 Sensors measurement corrections need to JMQ-500be made : Full Spectrum Quantum Meter JMQ-200 : Separate Sensor with Handheld Meter JMQ-303 : Line Quantum with 3 Sensors JMQ-210 : Underwater Quantum Meter JMQ-501 : Hand-held Full-spectrum Quantum Meter JMQ-306 : Line Quantum with 6 Sensors JMQ-510 : Full Spectrum Underwater Quantum

Spectral Type Model Output Power Supply Sensitivity Range

-1 JPS-100 JPS-200 JPS-300

s JSS-110 JSS-120 -1 Model -2 Visible to Near UV to Near -1 s -1 -1 UV to Visible Range s

-2 Infrared Range Infrared Range s s -2 -2 -2 Wavelength Range 340 to 820 nm 635 to 1100 nm 350 to 1150 nm 190 to 850 nm 220 to 1100 nm Sun Electric Irradiance Calibration Range ------350 to 1000 nm 300 to 850 nm 300 to 1000 nm Calibration Calibration Detector Type ------CCD, 2048 pixel Grating Type ------Holographic & Ruled, 600 g/nm Holographic & aberration-corrected, 500 g/nm Self-Powered 0.0064 mA / μmol m 0.01 mV / μmol m Data Log Software 1.0 mV / μmol m 0 to 800mV 0 to 40mV 0 to 2.5V 4 to 20 mA 0 to 5.0 V 0 to 4.0 V USB Output 410 to 655 nm 389 to 692nm ± 5nm 5 to 24V DC 5.5 to 24V DC 5 to 36V DC USB (5 VDC) 3V Battery(CR2320) 0.2 mV / μmol m 2.0 mV / μmol m Digitizer ------16-bit JSQ-110 JSQ-120 Ʌ Ʌ ɅɅ Wavelength Resolution 3.0 nm (full width half maximum) 1.0 nm 0.85 nm 1.5 nm JSQ-212 JSQ-222 ɅɅɅ Ʌ JSQ-214 JSQ-224 ɅɅɅ ɅSignal to Noise Ratio 1500:1 (at maximum signal 1000: 3 JSQ-215 JSQ-225 Ʌ Ʌ Ʌ Ʌ Integration Time Range 10 ms to 10 s 1 ms to 65 s JSQ-313 JSQ-323 Ʌ Ʌ Ʌ Ʌ JSQ-316 JSQ-326 Ʌ Ʌ Ʌ Ʌ Stray Light ≤ 0.25 % at 590 nm ≤ 0.25 % at 850 nm 0.1 % at 435 nm; 0.02 % at 435 nm; 0.02 % at 435 nm; JSQ-311 JSQ-321 Ʌ Ʌ Ʌ Ʌ 0.5 % at 600 nm 0.2 % at 200 nm 0.2 % at 200 nm JSQ-420 ɅɅ Ʌ Ʌ Dark Noise ≤ 3 counts --- JSQ-500 ɅɅɅ Ʌ JSQ-520 Ʌ Ʌ < 1.0 % (wavelengths < 1.0 % (wavelengths Ʌ Ʌ Ʌ Measurement Repeatability Less than 1 % JMQ-100 Ʉ greater than 400 nm) greater than 1020 nm) Ʌ Ʌ Ʌ Ʉ JMQ-200 Ʉ Ʉ Ʌ Ʌ Ʌ Fields of View 180° (upward-facing); 25° or 150° (downward-facing) --- JMQ-301 Ʉ Ʉ Ʌ Ʌ Ʌ JMQ-303 Ʉ Ʉ Calibration Uncertainty --- ± 10 % Ʌ Ʌ Ʌ JMQ-306 Ʉ Ʌ Ʌ Ʌ Ʉ Cosine Respons ± 5 % at 75° zenith angle ± 5 % at 80° zenith angle JMQ-210 Ʉ Ʉ Ʌ Ʌ Ʌ Interface 5 m jacket with USB (for computer) USB 2.0 JMQ-510 Ʉ Ʉ

Quantum Meter Quantum Sensor Ʌ Ʌ Ʌ JMQ-500 Ʉ Ʉ Power Requirement 1 Watt (USB) 100 mA at 5 V DC, supplied via USB cable Ʌ Ʌ Ʌ JMQ-501 Ʉ Ʉ Ʌ Ʌ Ʌ Dimensions / Base Unit 89.3(h) x 50.8(w) x 38.1(d) mm 25 x 75 x 125 mm 69 x 100 x 150 mm 69 x 100 x 150 mm ● : Standard ○ : Optional

www.jetec.com.tw 37 www.jetec.com.tw 38 Agriculture Weather Sensors Soil Sensors / Water Quality Sensors Agriculture Weather Sensors Water Quality Sensors

Soil Moisture, Temperature, pH Sensors Water Quality Sensors The Soil Sensors is for monitoring soil moisture levels, soil temperature or soil pH values in precision farming and Water quality sensors can measure water temperature, dissolved oxygen, pH, conductivity, turbidity. For use in environmental monitoring applications. algae-to-biofuels, aquaculture, educational research, and for general monitoring in oceanographic applications.

Soil Temperature Sensor Soil Moisture & Temp Probe Soil Moisture Probe Soil Moisture Meter Conductivity / Salinity Electrode pH, ORP & Temp. Electrode Multiparameter Sonde Dissolved CO2 SensorSe

JST-100 JSMT01 JSH-100 JVG-200 FC4E FPHEHT CWQ-Y4000 CP-CO2 For continuous measurement SDI-12 data interface with The stainless steel soil Probe to The probe can be buried and is This allows you a “plug & play” The sensor stores calibration & Programmable auto cleaning Involving immersion in water, of air, soil, or water. transient protection guarantee the life time. IP68 water proof system without re-calibration history data within the sensor wiper; Water proof connector oil, or water and oil mixtures Measurement range : -50 to 70°C Moisture Measurement Range : 0-100%RH Measurement Range : 0-100% Measurement Range : 0~100% VWC Conductivity Range : 0~200.0 , 0~2000 (μS/cm), pH Range : 0 – 14 pH Optical DO : 0-20 mg/L or 0-200% Air Saturation Range : 0-2000 ppm (by volume), 0-5000 ppm, Uncertainty : 0.1°C, 0.2°C or 0.4°C Moisture Measurement Resolution : 0.1%, Accuracy : ±3% (m3/m3) ( at 0~50%Rh) Accuracy : ±2% 0.00–20.00 , 0.0–200.0 (mS/cm) pH Accuracy : ± 0.1 pH Fiber Turbidity Sensor : 0-1000NTU 0-1%, 0-100% Repeatability : Less than 0.05 °C Temp. Measurement Range : -20~65°C Output : 0~2 / 0~5 / 0~10VDC, 4~20mA / 0~20mA Display: moisture, ambient air temp., light level, time Accuracy : ± 1 % of the full range ORP : - 1000 to + 1000 mV Conductivity Probe : 1 uS/cm~200 mS/cm TDGP : 0-3 bar Equilibration Time : 30 seconds Temp. Calibration Accuracy : ±0.5°C Response time : < 50ms Response time : 400ms Salinity Range :5-60 g/Kg ORP Accuracy :± 2 mV Digital pH Sensor : 2-12pH Accuracy : 2% of maximum range (CP-CO2) Operating Environment : -50~70°C, 0~100 %RH Interface : SDI-12 Probe Length : 55mm (diameter 3mm) Probe Length : 93.76(L) ×7.09(W) mm TDS -KCl Range : 0-133 000 ppm Temperature : -10°C to +50°C Chlorophyll Sensor : 0~400 ug/L or 0~100RF +1% (TDGP) Output Voltage Range : 0 to 2.5 V DC Operating Environment : -20~65°C, 0~100 %RH Operating Environment30 : -~70°C Operating Environment40 : -~85°C Response time : < 5 s Temperature Accuracy ±: 0.5 °C Blue Green Algae : 0~100ug/L or 0~100RFU Equilibration time(t63) : 3 minutes Interface : Modbus RS-485, SDI-12 (option) Response Time :< 5 s ORP Probe : -999~999mV Depth : 0-300 meters IP Protection Class : IP68 Interface : Modbus RS-485, SDI-12 (option) Temperature Sensor : 0-50°C Data output : RS-232 / 0-5 V or 4-20 mA Oxygen Sensors Oxygen Meter Soil pH And Moistureois Meter PH Electrode RoHS Temperature, Humidity And2 TransmitterCO

Outdoor T/H Transmitter Outdoor Temp. Transmitter T/H Transmitter T / H / CO2 Transmitter Self-Powered RoHS RoHS

JSO-100 And JSO-200 Series JMO-200 SPH-300 JASP2801 Gaseous oxygen measurement The JMO-200 display oxygen Provides pH and moisture Strong anti-interference in the laboratory & porous mediavalue & store measurements reading accurately fast ability; Long life Measurement Range : 0 to 100 % O2 Measurement Range : 0 to 100 % O2 PH Measurement Range : 3~8pH PH Measurement Range : 0~14pH RoHS Response Time : 14 seconds or 60 seconds Response Time : 14 seconds Moisture Measurement Range : 10~80% Output : ±411.6mV JTC-OTH6H6 JTS-110 JVT-250TH JVT-250 Output at 0%O2 : 3% or 6% of output at 20.95%2 O Repeatability : ± 0.1 % at 20.9 % O2 Accuracy : ±0.2PH , ±1%(moisture) Zero Potential : E0 = 7pH Resolution : 0.1 unit (< 9.9) , 1unit (>10) Oxygen Consumption Rate : Measurement Depth : 2~30cm Pressure Resistance : 0.6MP Multi-wing convection design; Built-in fan; For use on solar Suitable for humid and weeping water condition. Applicable to high Analog and RS485 output batter or powered stations humidity environment like a mushroom farm and floriculture industry Heater Current Drain : 6.2 mA 2.2 μmol O2 per day at 20.9 % O2 and 23°C Operating Environment5~50° : C Process Fittings : 3/4 NPT Measurement Range : 0 to 60°C, 0~100%RH Measurement Range : -50 to 70°C Measurement Type : Temp., RH Measurement Type : Temp., RH, CO2 Accureacy : ±0.3°C or ±1°C Aspiration Rate : 6 m s-1 at full speed; T/H Range : -25~85°C, 0-99.9% T/H Range : -25~85°C, 0-99.9% -1 ±3%RH or ±5%RH 3 m s at half speed Accuracy : ±0.3°C(T), ±2%(RH) CO2 Range : 0~3000/5000/10,000 ppm Liquid pH Measurements Output : 4-20mA, ModBus RTU Fan Input Voltage Requirement : 10.8 to 13.2 V DC Response Time : 5~30 sec(T), 8 sec(RH) Accuracy : ±0.3°C(T), ±2%(RH), ±2%(CO2) Sampling Cycle : 0.3 sec Fan IP Protection Class : IP55 Output : RS485 + 4~20mA or RS485 + 0~5V Output : RS485 + 4~20mA or RS485 + 0~5V Application for the pH monitoring in many industries such as agriculture, chemicals, water & wastewater, food & beverage, pharmaceuticals and power plants. pH Combination Electrode pH Electrode pH Electrode pH Meter Barometric Pressure And Leafs Measurement

Barometric Pressure Sensor Chlorophyll Concentration Meter How the Meter Works

RoHS RoHS

Non-destructive Sampling head Measurement EC-2001 JASPA2111 JASPS2121 CP-PH30F And CP-PH30L Non-Porous reference interface, The electrode is suitable for variousStrong anti-interference ability; 1-3 points push-button calibra- cannot be fouled or poisoned. medias with severe pollution Long life; Quick response tion with auto-buffer recognition JSB-100 JMC-100 PH Measurement Range : 0~12 pH PH Measurement Range : 0~14pH PH Measurement Range : 0~14pH Applications : Suitable for measuring the Application for pressure mea- Applications include chlorophyll concentration determination in plant surement in weather networks leaves for assessment of nutrient status, fertilizer requirements Reference : Ag/AgCl in KCl 2.8 mol/l electrolyte Output : ±411.6mV Output : ±411.6mV semisolid substances or small volume samples EO Zero : pH = 6.8 +/- pH 0.5 Zero Potential : E0 = 7pH Zero Potential : E0 = 7pH pH Range : -1.00~15.00pH Measurement Range:15-115 kPa (approximate) Display Output Unit : μmol of chlorophyll Data Output : Mini-B USB por 2 It uses LEDs that emit specific wavelengths in Pressure : Full Vacuum to 30 BAR Pressure Pressure Resistance : 0.6MP Pressure Resistance : 0.6MP pH Accuracy : ± 0.01pH Maximum Pressure Exposure: 400 kPa per m of leaf surface Repeatability : ± 1 % the red and infrared ranges. The detector analyzes IP Protection Class : IP69 Process Fittings : 3/4 NPT Process Fittings : 3/4 NPT Temperature Range : 0~60°C Output : 0-5V Optional Display Units : CCI, SPAD Sample Acquisition Time: Less than 3 s 2 the ratio of the two wavelengths to determine Process Fittings : 3/4" NPT The outer tube material: Glass The outer tube material : PPS plastic Power : 2×1.5V "AAA" batteries Response Time : 1 ms Measurement Area : 63.6 mm External GPS Option: RS-232 port Temperature Response : 0.1 % per °C Resolution : ± 10 μmol per m2 (GPS location data is saved with each measurement) chlorophyll concentration index.

www.jetec.com.tw 39 www.jetec.com.tw 40 Internet of Things System(IOT) 01 Measurement Instrumentation Customized Software (j-MoniSoft)

Temperarue and Humidity Datalogger 02 Temperarue and Humidity Transmitter CO / CO2 Transmitter Pressure Transmitter Flow Meter And Flow Switch Recorder and Data Logger Digital Temperature Controller Infrared Temperature Sensor Gas Detector Differential Pressure Transmitter Air Velocity And Air Flow Transmitter Wind And Rain Sensor Water Leak Sensors

Rain And Precipitation Sensor 03 Wind Speed And Wind Direction Sensor Solar Radiation Sensor (Pyranometer / Quantum Sensor / UV Sensor) Soil Sensor (Moisture / Temperature / pH / Oxygen) Water Quality Sensor (pH / EC / ORP / DO ) Barometric Pressure And Leafs Measurement

CONTACT INFORMATION

TAIWAN JETEC ELECTRONICS CO., LTD. No.7 Furen St., West Dist., Taichung City, 403-49 TAIWAN tel : +886 (4) 23729418 fax: +886 (4) 23724272 [email protected] www.jetec.com.tw

SSensorsensors ControllerC SSystemystem TransmitterT RecordeRecorderr IntegratIntegrationion