Heat Pumps & Chillers
Total Page:16
File Type:pdf, Size:1020Kb
AIR TO WATER Heat Pumps & Chillers R407C Ozone Friendly Refrigerant The Affordable Air to Water Heating & Cooling Reduce carbon footprint, save energy GREEN Self contained units, plug & play Solution Unmatched Zoning Capabilities AN Models Available in 4 different sizes (3, 5, 10, & 20 ton) • Cooling only or heat pump models available • Produces water/glycol cooled from 4°C (39°F) down to -6°C (21°F) • High efficiency scroll compressors with low power consumption. • Antifreeze electric heater for the storage tank. (Standard on AN 3007A) • Water side differential pressure switch standard on all models. • High efficiency stainless steel heat exchangers. • Axial flow fan units for extremely quiet operation. • Metallic protective cabinet with rustproof polyester paint. • Equipped with water pump and storage tank. Many applications such as Radiant in-floor heating, low temperature baseboard heating, towel warmers, domestic hot water systems, and even solar technologies are all supported by the Aermec Air-to-Water Heat Pumps & Chillers. There are no special tools to connect, no complicated wiring, and no refrigeration piping required. This advanced unit simply uses water or glycol to heat and cool all year round. The Aermec Advantage No Refrigerant Handling: No need to charge our air cooled Zoned Cooling: With Aermec air-cooled chillers and hydronic chiller system with refrigerant. Aermec closed ductless fan coils, you condition only the spaces you refrigerant system does away with the need for certified designate; not the whole building as opposed to a traditional installation technicians to handle refrigerants. Because there are ducted central AC system. This fact allows for diversity and no refrigerant lines outside the outdoor water chiller cabinet, load shifting when doing load and sizing calculations. This installation costs are lower versus standard DX ducted split reduces installed cost, as well as, operating costs for years to systems. come. No Ductwork: Cooling with Aermec chillers and our lines of Whisper Quiet Operation: The Aermec Fan Coils are the ductless hydronic fan coils means running small, flexible water world's quietest fan coils. At a 25.5 decibel rating, the fan coils pipes into spaces within the walls instead of large ductwork runs. emit lower noise than a whisper quiet library (30dB). These are This can save hundreds of useable square feet for living space. widely used in many hotel and condiminium applications that Using ductless fan coils results in zero percent duct air loss require a low-noise system. compared to traditional ducted systems. Zero Line Length Limitations: With insulated water lines Other notable advantages with Aermec, is its plug and play carrying the cooling capacity, there is minimal capacity loss feature. These remarkable units come equipped with built in, allowing for unlimited line length runs to any hydronic fan coil. expansion tank, water storage tank, pump, and strainers. This method of delivering rated capacity is far more efficient than Reducing the overall installation cost over traditional systems. traditional direct expansion ductless split systems. Case Studies Aermec is flexible with many applications in many different geographical locations. The AN Heat Pumps and Chillers are recognized for their efficiency and reliability. Most importantly, its unique plug & play feature makes it incredibly easy to install. Many establishments have embraced the Aermec product line. Some of which include major hotel chains, schools, hospitals, churches, large custom homes, and much more. To view these and many more Aermec Case Studies, please visit us online at: www.aermec.us or www.aermec.ca Simple, reliable, and proven worldwide Moda Hotel (British Columbia, Canada) St.Lawrence Church (Toronto, Canada) This prehistoric hotel built in 1908 is located in the heart of Aermec fan coils were installed and the existing radiator the Arts & Entertainment district of downtown Vancouver. covers were reinstalled. All piping was run in the existing The hotel consists of 57 rooms that hold a modern as well basement pipe chase. Fan coils were hung at the ceiling in as contemporary interior design. Situated inside the hotel the banquet hall utililizing the existing pipe chase as well. lobby, hotel guests can wine and dine at the "Uva Wine Two new condensing boilers replace the existing natural Bar" and "Cibo Trattoria". gas boiler. One of the great benefits Aermec was able to offer, was Installed were 5 ,10, and 20 ton chillers along with 44 fan being able to operate the units as heat pumps with a boiler coils, phase converters, and 2 boilers for domestic hot for backup for a complete heating system. Each suite has water. The goal was met, no changes to the beautiful its own fan coil with wireless thermostat which also sanctuary, a system that was quieter than opening the connects wirelessly to the reservation bridge of the main windows. Both, sanctuary and banquet hall could be lobby. The benefits of this wireless system is so that rooms cooled, higher efficiency heating, and all within budget. that are not occupied by guests are not being heated or cooled, thus saving energy. Beverly Hilton (Los Angeles, California) Robin Ridge Winery (British Columbia, Canada) This hotel was originally built in 1955. It is composed of Three Aermec AN417HA heat pumps are being used to 570 bedrooms, restaurants, well-being centre, provide comfort, cooling, and heating for the restaurant shopping,centre, garden, and swimming pool. area as well as refrigeration for the wine storage area. The winery chills glycol at -4º C (24ºF) for the production of Ice Remodeled in 2003, Aermec was chosen for its efficient Wine. cooling and whisper quiet fan coils. Turning Water into Comfort Aermec AN Chillers and Heat Pumps have been designed and constructed to satisfy small and medium sized cooling and heating applications in residential or commercial venues. The unit is designed for using both hydraulic circuits (evaporator and Water transfers 3,500 times the energy condensing unit); therefore it can be used both like water chiller and as the same volume of Air. heat pump. The communication between chiller and heat pump operation is obtained managing the chiller circuit. Available in 4 Fact: 90% of North Americans use forced air to sizes, the units are characterized by their silent operation, high heat and cool commercial and residential spaces. efficiency performance, and reliability, thanks to the use of heat exchangers with a large exchange surface and high-efficiency silent Fact: 98% of European commercial and scroll compressors. residential utilizes water for heating and cooling. The units can be arranged to satisfy a wide range of system requirements. With base or with integrated pump and storage tank. Condensing units without an evaporator are also available. Genious Design Aermec offers complete flexibility to work with many applications. The residential home shown below demonstrates how versatile the Aermec system can be. Solar panel Ducting Floor standing Fan Coils Radiant In-Floor Heating Hot Water Tank or Tankless Water Outdoor Unit AN Technical Specs Version AN 0417 AN 0807 AN 1507 AN 3007 10.4 18.2 35 70 / 66.5** All 35486 62100 119425 238850/226907 A 3.86 6.40 12.9 24.05/ 24.2 ** A 19.8 28.5 40 71.5/77.5** 1790 3130 6020 12040/11440** All 7.88 13.78 26.50 53.01 / 50.36 ** A 61/8.84 57/ 8.26 68/9.86 128/18.56133**/19.29 11.8 19.2 35.0 75.0 HA 40260 65510 119425 255910 HA 4.60 7.10 12.7 27.5 HA 22.3 29.7 45.0 81.1 Minimum Circuit 28/28 36/36 53/53 117/120 Ampacity (MCA) HA/A HA 2030 3300 6020 12900 8.93 14.52 26.50 56.79 All 37 41 49 49 All 5300 6700 12400 21000 3120 3943 7298 12360 A 1/25.4 1.25/31.75 1.25/31.75 2.5/ 63.5 3. All 0.85/2.2g 1.41/.372g 1/.818g 6.48/1.4g A 3 3 1 1 A 5.0/ 1.32 5.0/ 1.32 8/2.11 24/ 6.34 A 35/9.24 75/19.81 145/38.3 500/132 • • MAIN COMPONENTS 1. Switchboard 2. Air Side Exchanger 3. Fan Section 4. Water Side Exchanger 5. High Pressure Switch 6. Compressor 7. Expansion Tank 8. Water Storage Tank 9. Pump 10. Low Pressure Switch 11. Thermostatic Valve 12. Water Filter 13. Safety Valve 14. Differential Pressure Switch AN 0807A AN Dimensions .