Heat Pumps & Chillers

Total Page:16

File Type:pdf, Size:1020Kb

Heat Pumps & Chillers AIR TO WATER Heat Pumps & Chillers R407C Ozone Friendly Refrigerant The Affordable Air to Water Heating & Cooling Reduce carbon footprint, save energy GREEN Self contained units, plug & play Solution Unmatched Zoning Capabilities AN Models Available in 4 different sizes (3, 5, 10, & 20 ton) • Cooling only or heat pump models available • Produces water/glycol cooled from 4°C (39°F) down to -6°C (21°F) • High efficiency scroll compressors with low power consumption. • Antifreeze electric heater for the storage tank. (Standard on AN 3007A) • Water side differential pressure switch standard on all models. • High efficiency stainless steel heat exchangers. • Axial flow fan units for extremely quiet operation. • Metallic protective cabinet with rustproof polyester paint. • Equipped with water pump and storage tank. Many applications such as Radiant in-floor heating, low temperature baseboard heating, towel warmers, domestic hot water systems, and even solar technologies are all supported by the Aermec Air-to-Water Heat Pumps & Chillers. There are no special tools to connect, no complicated wiring, and no refrigeration piping required. This advanced unit simply uses water or glycol to heat and cool all year round. The Aermec Advantage No Refrigerant Handling: No need to charge our air cooled Zoned Cooling: With Aermec air-cooled chillers and hydronic chiller system with refrigerant. Aermec closed ductless fan coils, you condition only the spaces you refrigerant system does away with the need for certified designate; not the whole building as opposed to a traditional installation technicians to handle refrigerants. Because there are ducted central AC system. This fact allows for diversity and no refrigerant lines outside the outdoor water chiller cabinet, load shifting when doing load and sizing calculations. This installation costs are lower versus standard DX ducted split reduces installed cost, as well as, operating costs for years to systems. come. No Ductwork: Cooling with Aermec chillers and our lines of Whisper Quiet Operation: The Aermec Fan Coils are the ductless hydronic fan coils means running small, flexible water world's quietest fan coils. At a 25.5 decibel rating, the fan coils pipes into spaces within the walls instead of large ductwork runs. emit lower noise than a whisper quiet library (30dB). These are This can save hundreds of useable square feet for living space. widely used in many hotel and condiminium applications that Using ductless fan coils results in zero percent duct air loss require a low-noise system. compared to traditional ducted systems. Zero Line Length Limitations: With insulated water lines Other notable advantages with Aermec, is its plug and play carrying the cooling capacity, there is minimal capacity loss feature. These remarkable units come equipped with built in, allowing for unlimited line length runs to any hydronic fan coil. expansion tank, water storage tank, pump, and strainers. This method of delivering rated capacity is far more efficient than Reducing the overall installation cost over traditional systems. traditional direct expansion ductless split systems. Case Studies Aermec is flexible with many applications in many different geographical locations. The AN Heat Pumps and Chillers are recognized for their efficiency and reliability. Most importantly, its unique plug & play feature makes it incredibly easy to install. Many establishments have embraced the Aermec product line. Some of which include major hotel chains, schools, hospitals, churches, large custom homes, and much more. To view these and many more Aermec Case Studies, please visit us online at: www.aermec.us or www.aermec.ca Simple, reliable, and proven worldwide Moda Hotel (British Columbia, Canada) St.Lawrence Church (Toronto, Canada) This prehistoric hotel built in 1908 is located in the heart of Aermec fan coils were installed and the existing radiator the Arts & Entertainment district of downtown Vancouver. covers were reinstalled. All piping was run in the existing The hotel consists of 57 rooms that hold a modern as well basement pipe chase. Fan coils were hung at the ceiling in as contemporary interior design. Situated inside the hotel the banquet hall utililizing the existing pipe chase as well. lobby, hotel guests can wine and dine at the "Uva Wine Two new condensing boilers replace the existing natural Bar" and "Cibo Trattoria". gas boiler. One of the great benefits Aermec was able to offer, was Installed were 5 ,10, and 20 ton chillers along with 44 fan being able to operate the units as heat pumps with a boiler coils, phase converters, and 2 boilers for domestic hot for backup for a complete heating system. Each suite has water. The goal was met, no changes to the beautiful its own fan coil with wireless thermostat which also sanctuary, a system that was quieter than opening the connects wirelessly to the reservation bridge of the main windows. Both, sanctuary and banquet hall could be lobby. The benefits of this wireless system is so that rooms cooled, higher efficiency heating, and all within budget. that are not occupied by guests are not being heated or cooled, thus saving energy. Beverly Hilton (Los Angeles, California) Robin Ridge Winery (British Columbia, Canada) This hotel was originally built in 1955. It is composed of Three Aermec AN417HA heat pumps are being used to 570 bedrooms, restaurants, well-being centre, provide comfort, cooling, and heating for the restaurant shopping,centre, garden, and swimming pool. area as well as refrigeration for the wine storage area. The winery chills glycol at -4º C (24ºF) for the production of Ice Remodeled in 2003, Aermec was chosen for its efficient Wine. cooling and whisper quiet fan coils. Turning Water into Comfort Aermec AN Chillers and Heat Pumps have been designed and constructed to satisfy small and medium sized cooling and heating applications in residential or commercial venues. The unit is designed for using both hydraulic circuits (evaporator and Water transfers 3,500 times the energy condensing unit); therefore it can be used both like water chiller and as the same volume of Air. heat pump. The communication between chiller and heat pump operation is obtained managing the chiller circuit. Available in 4 Fact: 90% of North Americans use forced air to sizes, the units are characterized by their silent operation, high heat and cool commercial and residential spaces. efficiency performance, and reliability, thanks to the use of heat exchangers with a large exchange surface and high-efficiency silent Fact: 98% of European commercial and scroll compressors. residential utilizes water for heating and cooling. The units can be arranged to satisfy a wide range of system requirements. With base or with integrated pump and storage tank. Condensing units without an evaporator are also available. Genious Design Aermec offers complete flexibility to work with many applications. The residential home shown below demonstrates how versatile the Aermec system can be. Solar panel Ducting Floor standing Fan Coils Radiant In-Floor Heating Hot Water Tank or Tankless Water Outdoor Unit AN Technical Specs Version AN 0417 AN 0807 AN 1507 AN 3007 10.4 18.2 35 70 / 66.5** All 35486 62100 119425 238850/226907 A 3.86 6.40 12.9 24.05/ 24.2 ** A 19.8 28.5 40 71.5/77.5** 1790 3130 6020 12040/11440** All 7.88 13.78 26.50 53.01 / 50.36 ** A 61/8.84 57/ 8.26 68/9.86 128/18.56133**/19.29 11.8 19.2 35.0 75.0 HA 40260 65510 119425 255910 HA 4.60 7.10 12.7 27.5 HA 22.3 29.7 45.0 81.1 Minimum Circuit 28/28 36/36 53/53 117/120 Ampacity (MCA) HA/A HA 2030 3300 6020 12900 8.93 14.52 26.50 56.79 All 37 41 49 49 All 5300 6700 12400 21000 3120 3943 7298 12360 A 1/25.4 1.25/31.75 1.25/31.75 2.5/ 63.5 3. All 0.85/2.2g 1.41/.372g 1/.818g 6.48/1.4g A 3 3 1 1 A 5.0/ 1.32 5.0/ 1.32 8/2.11 24/ 6.34 A 35/9.24 75/19.81 145/38.3 500/132 • • MAIN COMPONENTS 1. Switchboard 2. Air Side Exchanger 3. Fan Section 4. Water Side Exchanger 5. High Pressure Switch 6. Compressor 7. Expansion Tank 8. Water Storage Tank 9. Pump 10. Low Pressure Switch 11. Thermostatic Valve 12. Water Filter 13. Safety Valve 14. Differential Pressure Switch AN 0807A AN Dimensions .
Recommended publications
  • District Heating System, Which Is More Efficient Than
    Supported by ECOHEATCOOL Work package 3 Guidelines for assessing the efficiency of district heating and district cooling systems This report is published by Euroheat & Power whose aim is to inform about district heating and cooling as efficient and environmentally benign energy solutions that make use of resources that otherwise would be wasted, delivering reliable and comfortable heating and cooling in return. The present guidelines have been developed with a view to benchmarking individual systems and enabling comparison with alternative heating/cooling options. This report is the report of Ecoheatcool Work Package 3 The project is co-financed by EU Intelligent Energy Europe Programme. The project time schedule is January 2005-December 2006. The sole responsibility for the content of this report lies with the authors. It does not necessarily reflect the opinion of the European Communities. The European Commission is not responsible for any use that may be made of the information contained therein. Up-to-date information about Euroheat & Power can be found on the internet at www.euroheat.org More information on Ecoheatcool project is available at www.ecoheatcool.org © Ecoheatcool and Euroheat & Power 2005-2006 Euroheat & Power Avenue de Tervuren 300, 1150 Brussels Belgium Tel. +32 (0)2 740 21 10 Fax. +32 (0)2 740 21 19 Produced in the European Union ECOHEATCOOL The ECOHEATCOOL project structure Target area of EU28 + EFTA3 for heating and cooling Information resources: Output: IEA EB & ES Database Heating and cooling Housing statistics
    [Show full text]
  • Small Air to Water Heat Pump Chiller | Resdiential Hydronic Heat Pump
    The World’s Most Efficient Chiller Heat Pump Ultra-Efficient Multiple IDUs - Up to 8 Indoor Units Per CX34 CX34 Air-To-Water Heat Pump 2 Tons Cooling / 3 Tons heating IPLV Cooling 26,615 BTU COP 6.75 EER 23.02 Heating 33,813 BTU COP 3.92 Save More w/ DC Inverter Fan Motors All of the thin-line (5.1" thin) wall, floor and ceiling fan coil units use high efficiency and nearly silent DC Inverter fan motors, designed for 115v 50/60Hz power. 220v 50/60Hz standard FCUs are available for export customers. Geothermal Performance There is no Energy Star program for air to water heat pumps. However, the Chiltrix air-cooled chiller exceeds the Energy Star EER requirements for geothermal water-to-water systems. Server Room Cooling Ultra High Efficiency Heat Pump Chiller Chiltrix offers an optional Free Cooling add-on which allows up The CX34 obtains its ultra high efficiency using existing technologies in to EER 141+ & COP 41+ cooling performance during winter at a new way. For example, we use a DC Inverter compressor and a DC low ambient temperatures. Chiltrix chillers are also available Inverter water pump (both are variable speed) controlled together with in a N+1 redundant configuration. a DC inverter fan motor to achieve the best possible balance of water flow rate, compressor speed, and energy use. Solar Ready Perfect for solar PV operation with super low power draw and A special control algorithm looks at the temperature delta between the a 2 amp soft start that’s easy on inverters and batteries.
    [Show full text]
  • Idronics 13: Hydronic Cooling
    "@KDEkCaleffi-NQSG North America, LDQHB@ (MB Inc. 6 ,HKV@TJDD1C9850 South 54th Street ,HKV@TJDD 6HRBNMRHMFranklin, WI 53132 3 % T: 414.421.1000 F: 414.421.2878 Dear Hydronic and Plumbing Professional, Dear Hydronic Professional, Cooling a living space using chilled water is not new. Visit a high-rise hotel nd roomWelcome in summer, to the and2 edition notice ofhow idronics it is cooled. – Caleffi’s Chances semi-annual are that design cool journal air enters for fromhydronic a vent professionals.located in the wall or ceiling. Behind the vent is a heat exchanger withThe chilled 1st edition water of flowing idronics into was it. released The water in January absorbs 2007 the and heat distributed from room to airover and80,000 carries people it back in North to a chillerAmerica. that It extractsfocused onthe the heat topic and hydraulic rejects separation.it outside From thethe building. feedback After received, being it’sre-cooled, evident wethe attained water returns our goal back of explaining to the room— the benefits completingand proper the application cooling cycle. of this modern design technique for hydronic systems. A Technical Journal WithIf you advances haven’t inyet technology, received a copyhydronic of idronics cooling #1, is you no canlonger do solimited by sending to high- in the from risesattached and other reader large response commercial card, or buildings. by registering Improvements online at www.caleffi.us in chilled-water. The publication will be mailed to you free of charge. You can also download the Caleffi Hydronic Solutions generators,complete journaldistribution as a PDFequipment file from and our pipingWeb site.
    [Show full text]
  • Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes
    Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes P. Engelmann, K. Roth, and V. Tiefenbeck Fraunhofer Center for Sustainable Energy Systems January 2013 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, subcontractors, or affiliated partners makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights.Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof.The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. Available electronically at http://www.osti.gov/bridge Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN 37831-0062 phone: 865.576.8401 fax: 865.576.5728 email:mailto:[email protected] Available for sale to the public, in paper, from: U.S. Department of Commerce National Technical Information Service 5285 Port Royal Road Springfield, VA 22161 phone: 800.553.6847 fax: 703.605.6900 email: [email protected] online ordering: http://www.ntis.gov/ordering.htm Printed on paper containing at least 50% wastepaper, including 20% postconsumer waste Comfort, Indoor Air Quality, and Energy Consumption in Low Energy Homes Prepared for: The National Renewable Energy Laboratory On behalf of the U.S.
    [Show full text]
  • Operating and Maintenance Manual Slope Or Flat Top Console Unit
    Operating and Maintenance Manual CHPW Slope or Flat Top Console Unit Water Source Heat Pump (WSHP) Unit Contents Welcome Welcome........................................................ 2 Congratulations on your selection of the ICE AIR Water Source Heat Consumer Safety Information/Guidelines ... 3 Pump (WSHP). The WSHP is a combination cooling and heating Components and Parts View ........................ 4 unit that provides an efficient room by room source for comfort Nomenclature ............................................... 5 conditioning of your living environment. Controls ......................................................... 6 ICE AIR WSHP Console units are built to a high standard of quality LCD Programmable Operation..................7-9 and reliability, employing commercial grade components and heavy Maintenance ..........................................10-11 duty, galvanized sheet metal casings. With proper maintenance and Troubleshooting .......................................... 12 usage, ICE AIR WSHPs should provide many years of efficient, quiet Warranty/Contact Information ................... 16 and trouble-free comfort. To enhance the use of your ICE AIR equipment, you will want to read and carefully follow all of the instructions contained in this Operating and Maintenance Manual. We recommend that you pay special attention to the Safety and Warning Information section at the beginning of this Manual, and to the various safety advisories throughout this Manual. Please retain this Manual for your future reference. We suggest that you keep it with other important documents and product manuals. If your unit has optional features, they will be explained in a separate instruction sheet specific to that option. On behalf of ICE AIR, and our network of distributors and dealers, we are happy to welcome you to our base of satisfied customers! We recommend that you record the following information about your ICE AIR product(s).
    [Show full text]
  • Indoor Ultrafine Particle Exposures and Home Heating Systems
    Journal of Exposure Science and Environmental Epidemiology (2007) 17, 288–297 r 2007 Nature Publishing Group All rights reserved 1559-0631/07/$30.00 www.nature.com/jes Indoor ultrafine particle exposures and home heating systems: A cross-sectional survey of Canadian homes during the winter months SCOTT WEICHENTHAL, ANDRE DUFRESNE, CLAIRE INFANTE-RIVARD AND LAWRENCE JOSEPH Department of Epidemiology, Biostatistics and Occupational Health, Faculty of Medicine, McGill University, Que´bec, Canada Exposure to airborneparticulate matter has a negative effect onrespiratory health inboth childrenandadults. Ultrafineparticle (UFP) exposures a re of particular concern owing to their enhanced ability to cause oxidative stress and inflammation in the lungs. In this investigation, our objective was to examine the contribution of home heating systems (electric baseboard heaters, wood stoves, forced-air oil/natural gas furnace) to indoor UFP exposures. We conducted a cross-sectional survey in 36 homes in the cities of Montre´ al, Que´ bec, and Pembroke, Ontario. Real-time measures of indoor UFP concentrations were collected in each home for approximately 14 h, and an outdoor UFP measurement was collected outside each home before indoor sampling. A home-characteristic questionnaire was also administered, and air exchange rates were estimated using carbon dioxide as a tracer gas. Average UFP exposures of 21,594 cmÀ3 (95% confidence interval (CI): 14,014, 29,174) and 6660 cmÀ3 (95% CI: 4339, 8982) were observed for the evening (1600–2400) and overnight (2400–0800) hours, respectively. In an unadjusted comparison, overnight baseline UFP exposures were significantly greater in homes with electric baseboard heaters as compared to homes using forced-air oil or natural gas furnaces, and homes using wood stoves had significantly greater overnight baseline UFP exposures than homes using forced-air natural gas furnaces.
    [Show full text]
  • Home Heating and Cooling 2
    iowa energy center Home Series Home Heating and Cooling 2 Reduce your utility bills with low-cost, low-tech tips Get more heat from every energy dollar you spend—page 3 Make the most of your air-conditioning system—page 10 Landscape your yard for year-round comfort—page 19 Save with a whole-house approach Every year, a typical family in the United States spends around half of its home Did you know? energy budget on heating and cooling. In Iowa, that percentage can be higher, due The Energy Independence and to temperature extremes reached during the winter and summer months. Security Act of 2007 sets the Unfortunately, many of those dollars often are wasted, because conditioned air stage for significant changes in escapes through leaky ceilings, walls and foundations—or flows through energy policy across the United inadequately insulated attics, exterior walls and basements. In addition, many States for many years to come. During the next several years, new heating systems and air conditioners aren’t properly maintained or are more than energy-efficiency standards will 10 years old and very inefficient, compared to models being sold today. be put into place for appliances, As a result, it makes sense to analyze your home as a collection of systems that furnace motors, residential boilers and other energy-using devices. So, must work together in order to achieve peak energy savings. For example, you won’t watch for the latest news about tax get anywhere near the savings you’re expecting from a new furnace if your air- credits for homeowners who make handling ducts are uninsulated and leak at every joint.
    [Show full text]
  • Measuring a Heating Systemls Efficiency
    45% 57% Space heating is the largest The most common home energy expense in your home, heating fuel is natural gas, accounting for about 45 percent of and it’s used in about 57 percent your energy bills. of American homes. Between 2007 and 2012, the average U.S. household spent more than $700 $1,700 on heating using on heating homes natural gas using heating oil. Before upgrading your heating system, improve the efficiency of your house. This will allow you to purchase a smaller unit, saving you money on the upgrade and operating costs. All heating systems have three basic components. If your heating system isn’t working properly, one of these basic components could be the problem. 68 The heat source -- most The heat distribution The control system -- most commonly a furnace or system -- such as forced air or commonly a thermostat -- boiler -- provides warm air radiators -- moves warm air regulates the amount of to heat the house. through the home. warm air that is distributed. Furnaces and boilers are often called CENTRAL HEATING SYSTEMS because the heat is generated in a central location and then distributed throughout the house. INSTALL A PROGRAMMABLE THERMOSTAT and save big on your energy bills! Save68 an estimated 10 percent a year on heating and cooling costs by using a programmable thermostat. HEAT ACTIVE SOLAR ELECTRIC FURNACES BOILERS PUMPS HEATING HEATING A furnace heats air and uses a A boiler heats water to provide A heat pump pulls heat from the The sun heats a liquid or air in a Sometimes called electric blower motor and air ducts to hot water or steam for heating surrounding air to warm the solar collector to provide resistance heating, electric distribute warm air throughout that is then distributed through house.
    [Show full text]
  • Test Method 28 WHH for Measurement of Particulate Emissions and Heating Efficiency of Wood-Fired Hydronic Heating Appliances
    Method 28 WHH 8/3/2017 While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. To see a complete version including any recent edits, visit: https://www.ecfr.gov/cgi-bin/ECFR?page=browse and search under Title 40, Protection of Environment. Test Method 28 WHH for Measurement of Particulate Emissions and Heating Efficiency of Wood-Fired Hydronic Heating Appliances 1.0 Scope and Application 1.1 This test method applies to wood-fired hydronic heating appliances. The units typically transfer heat through circulation of a liquid heat exchange media such as water or a water- antifreeze mixture. 1.2 The test method measures particulate emissions and delivered heating efficiency at specified heat output rates based on the appliance’s rated heating capacity. 1.3 Particulate emissions are measured by the dilution tunnel method as specified in ASTM E2515-11 Standard Test Method for Determination of Particulate Matter Emissions Collected in a Dilution Tunnel. Upon request, four-inch filters may be used. Upon request, Teflon-coated glass fiber filters may be used. Delivered efficiency is measured by determining the heat output through measurement of the flow rate and temperature change of water circulated through a heat exchanger external to the appliance and determining the input from the mass of dry wood fuel and its higher heating value. Delivered efficiency does not attempt to account for pipeline loss. 1.4 Products covered by this test method include both pressurized and non-pressurized heating appliances intended to be fired with wood.
    [Show full text]
  • Solar Water Heating System Experimental Apparatus
    AC 2012-3019: SOLAR WATER HEATING SYSTEM EXPERIMENTAL APPARATUS Dr. Hosni I. Abu-Mulaweh, Indiana University-Purdue University, Fort Wayne Hosni I. Abu-Mulaweh is professor of mechanical engineering currently on sabbatical leave at King Faisal University, Saudi Arabia. He earned his B.S., M.S., and Ph.D. in mechanical engineering from Missouri University of Science and Technology (formerly, University of Missouri, Rolla), Rolla, Mo. His areas of interest are heat transfer, thermodynamics, and fluid mechanics. Page 25.1168.1 Page c American Society for Engineering Education, 2012 Solar Water Heating System Experimental Apparatus Department of Mechanical Engineering King Faisal University Al-Ahasa 31982, Saudi Arabia Abstract This paper describes the design and development of an experimental apparatus for demonstrating solar water heating. This solar heating experimental apparatus was designed to meet several requirements: 1) the system is to operate using the thermosiphon concept, in which flow through the system is created by density differences in the fluid; 2) to increase the solar energy absorbed by the water and improve the educational value of the project, the solar collector must have the ability to rotate in order to maintain a position perpendicular to the sun’s rays; 3) the experimental apparatus must be mobile. A prototype of a solar water heating system was constructed and tested. The solar collector rotated as the sun position/angle was changing, indicating the functionality of the control system that was design to achieve this task. Experimental measurements indicate that the water in the tank was heated by the solar energy being absorbed by the solar collector.
    [Show full text]
  • Thermosyphon System Design Senior Project Final Report
    Thermosyphon System Design Senior Project Final Report Team Members: Ben Jordan Nick Kipe Tyler Thumma Advisor: Dr. Ressler Abstract The Themosyphon Design Project intended to verify or adjust, if necessary, the current mathematical model of a thermosyphon hot water heater collector by building and testing appropriate prototypes of the collector and comparing these tests with the mathematical model. In the process of constructing these prototypes, we were also able to make manufacturing recommendations for the construction of the collectors and create a materials cost list based on the materials we use to construct them. The Thermosyphon Team consisted of Ben Jordan, Nick Kipe and Tyler Thumma. The Collaboratory Energy Group sponsored this project, while Dr. Ressler and Brendon Earl were the advisors. 2 Table of Contents 1 Introduction ............................................................................................................................ 4 2 Design Process ..................................................................................................................... 14 3 Implementation .................................................................................................................... 19 4 Schedule ................................................................................................................................ 48 5 Budget ................................................................................................................................... 49 6 Conclusions .........................................................................................................................
    [Show full text]
  • Use of Low Enthalpy Geothermal Energy for Heating
    USE OF LOW ENTHALPY GEOTHERMAL ENERGY FOR HEATING Jean LEMALE Ademe - de France, Tour 13 92082 Paris La 2, FRANCE Key words: district heating, distribution system, machinery, Paris region, INTRODUCTION The temperature of the resource is a function of depth and local temperature gradient. The temperature at the well head is a few Almost all the geothermal plants in France are associated with a degrees lower than that at the well bottom, and the greater the heating network serving residential units and associated urban output, the smaller is this difference. The factors that determine facilities. It is estimated that approximately 200,000 housing flow rate are the transmissivity (the ability of a porous rock to permit equivalents are at present connected to urban heating networks based fluid to flow through it) of the reservoir and the static pressure of the on geothermal energy More than 80% of these are within the Paris fluid. Where conditions are favourable, artesian exploitation is region where a perfect set of conditions exists between an easily possible; elsewhere, or if a maximum flow rate is sought, then a mobilized resource and a concentration of habitations of apartment submersible pump is installed. Well diameter also influences flow dwellings. rate, for example, the difference in cost between the slightly more expensive 9 well and a 7" well is, in general, rapidly Two scenarios are met with; either a heating network already existed compensated for by an increased flow rate. before the introduction of the geothermal heating, or a completely new heating network had to be constructed to exploit the available Raising the flow rate by pumping means higher electricity geothermal energy In the first case it was necessary to make the consumption.
    [Show full text]