Potassium Permanganate

Total Page:16

File Type:pdf, Size:1020Kb

Potassium Permanganate Safety data sheet according to Regulation (EC) No. 1907/2006 (REACH) Potassium permanganate ≥99 %, p.a., ACS article number: P752 date of compilation: 2015-08-17 Version: 3.1 en Revision: 2021-03-03 Replaces version of: 2020-06-10 Version: (3) SECTION 1: Identification of the substance/mixture and of the company/ undertaking 1.1 Product identifier Identification of the substance Potassium permanganate ≥99 %, p.a., ACS Article number P752 Registration number (REACH) 01-2119480139-34-xxxx Index number in CLP Annex VI 025-002-00-9 EC number 231-760-3 CAS number 7722-64-7 1.2 Relevant identified uses of the substance or mixture and uses advised against Relevant identified uses: Laboratory chemical Laboratory and analytical use Uses advised against: Do not use for products which come into direct contact with the skin. Do not use for products which come into contact with foodstuffs. Do not use for private purposes (household). 1.3 Details of the supplier of the safety data sheet Carl Roth GmbH + Co KG Schoemperlenstr. 3-5 D-76185 Karlsruhe Germany Telephone:+49 (0) 721 - 56 06 0 Telefax: +49 (0) 721 - 56 06 149 e-mail: [email protected] Website: www.carlroth.de Competent person responsible for the safety data :Department Health, Safety and Environment sheet: e-mail (competent person): [email protected] 1.4 Emergency telephone number Name Street Postal Telephone Website code/city National Poisons Information Beaumont Road Dublin 9 01 809 2166 https:// Centre www.poisons.ie/ Beaumont Hospital Ireland (en) Page 1 / 17 Safety data sheet according to Regulation (EC) No. 1907/2006 (REACH) Potassium permanganate ≥99 %, p.a., ACS article number: P752 SECTION 2: Hazards identification 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 (CLP) Section Hazard class Cat- Hazard class and Hazard egory category statement 2.14 Oxidising solid 2 Ox. Sol. 2 H272 3.1O Acute toxicity (oral) 4 Acute Tox. 4 H302 3.2 Skin corrosion/irritation 1C Skin Corr. 1C H314 3.3 Serious eye damage/eye irritation 1 Eye Dam. 1 H318 3.7 Reproductive toxicity 2 Repr. 2 H361d 3.9 Specific target organ toxicity - repeated exposure 2 STOT RE 2 H373 4.1A Hazardous to the aquatic environment - acute hazard 1 Aquatic Acute 1 H400 4.1C Hazardous to the aquatic environment - chronic hazard 1 Aquatic Chronic 1 H410 For full text of abbreviations: see SECTION 16 The most important adverse physicochemical, human health and environmental effects Skin corrosion produces an irreversible damage to the skin; namely, visible necrosis through the epi- dermis and into the dermis. Delayed or immediate effects can be expected after short or long-term exposure. Spillage and fire water can cause pollution of watercourses. 2.2 Label elements Labelling according to Regulation (EC) No 1272/2008 (CLP) Signal word Danger Pictograms GHS03, GHS05, GHS07, GHS08, GHS09 Hazard statements H272 May intensify fire; oxidiser H302 Harmful if swallowed H314 Causes severe skin burns and eye damage H361d Suspected of damaging the unborn child H373 May cause damage to organs (brain) through prolonged or repeated exposure (if inhaled) H410 Very toxic to aquatic life with long lasting effects Precautionary statements Precautionary statements - prevention P220 Keep away from clothing and other combustible materials P273 Avoid release to the environment P280 Wear protective gloves/eye protection Ireland (en) Page 2 / 17 Safety data sheet according to Regulation (EC) No. 1907/2006 (REACH) Potassium permanganate ≥99 %, p.a., ACS article number: P752 For professional users only Labelling of packages where the contents do not exceed 125 ml Signal word: Danger Symbol(s) H314 Causes severe skin burns and eye damage. H361d Suspected of damaging the unborn child. P280 Wear protective gloves/eye protection. 2.3 Other hazards Results of PBT and vPvB assessment According to the results of its assessment, this substance is not a PBT or a vPvB. SECTION 3: Composition/information on ingredients 3.1 Substances Name of substance Potassium permanganate Molecular formula KMnO₄ g Molar mass 158 /mol REACH Reg. No 01-2119480139-34-xxxx CAS No 7722-64-7 EC No 231-760-3 Index No 025-002-00-9 Specific Conc. Limits M-Factors ATE Exposure route mg M-factor (acute) = 10.0 500 /kg oral SECTION 4: First aid measures 4.1 Description of first aid measures General notes Take off immediately all contaminated clothing. Following inhalation Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice. Following skin contact After contact with skin, wash immediately with plenty of water. Immediate medical treatment re- quired because corrosive injuries that are not treated are hard to cure. Ireland (en) Page 3 / 17 Safety data sheet according to Regulation (EC) No. 1907/2006 (REACH) Potassium permanganate ≥99 %, p.a., ACS article number: P752 Following eye contact In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes hold- ing eyelids apart and consult an ophthalmologist. Protect uninjured eye. Following ingestion Rinse mouth immediately and drink plenty of water. Rinse mouth with water (only if the person is conscious). Call a physician immediately. If swallowed danger of perforation of the esophagus and the stomach (strong corrosive effects). 4.2 Most important symptoms and effects, both acute and delayed Irritant effects, Corrosion, Risk of serious damage to eyes, Risk of blindness, Gastric perforation, Nausea, Vomiting, Gastrointestinal complaints, Cough, Dyspnoea 4.3 Indication of any immediate medical attention and special treatment needed none SECTION 5: Firefighting measures 5.1 Extinguishing media Suitable extinguishing media co-ordinate firefighting measures to the fire surroundings water, foam, alcohol resistant foam, dry extinguishing powder, ABC-powder Unsuitable extinguishing media water jet 5.2 Special hazards arising from the substance or mixture Oxidising property. Non-combustible. 5.3 Advice for firefighters In case of fire and/or explosion do not breathe fumes. Do not allow firefighting water to enter drains or water courses. Fight fire with normal precautions from a reasonable distance. Wear self-contained breathing apparatus. Wear full chemical protective clothing. SECTION 6: Accidental release measures 6.1 Personal precautions, protective equipment and emergency procedures For non-emergency personnel Use personal protective equipment as required. Avoid contact with skin, eyes and clothes. Do not breathe dust. 6.2 Environmental precautions Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it. 6.3 Methods and material for containment and cleaning up Ireland (en) Page 4 / 17 Safety data sheet according to Regulation (EC) No. 1907/2006 (REACH) Potassium permanganate ≥99 %, p.a., ACS article number: P752 Advice on how to contain a spill Covering of drains. Take up mechanically. Advice on how to clean up a spill Take up mechanically. Control of dust. Other information relating to spills and releases Place in appropriate containers for disposal. 6.4 Reference to other sections Hazardous combustion products: see section 5. Personal protective equipment: see section 8. Incom- patible materials: see section 10. Disposal considerations: see section 13. SECTION 7: Handling and storage 7.1 Precautions for safe handling Handle and open container with care. Avoid exposure. Avoid dust formation. Clear contaminated areas thoroughly. Measures to prevent fire as well as aerosol and dust generation Removal of dust deposits. Keep away from combustible material. Measures to protect the environment Avoid release to the environment. Advice on general occupational hygiene Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs. 7.2 Conditions for safe storage, including any incompatibilities Store in a dry place. Keep container tightly closed. Keep away from combustible material. Incompatible substances or mixtures Observe hints for combined storage. Keep/store away from clothing/combustible materials. Take any precaution to avoid mixing with combustibles. Consideration of other advice Ventilation requirements Use local and general ventilation. Specific designs for storage rooms or vessels Recommended storage temperature: 15 – 25 °C 7.3 Specific end use(s) No information available. SECTION 8: Exposure controls/personal protection 8.1 Control parameters National limit values Ireland (en) Page 5 / 17 Safety data sheet according to Regulation (EC) No. 1907/2006 (REACH) Potassium permanganate ≥99 %, p.a., ACS article number: P752 Occupational exposure limit values (Workplace Exposure Limits) Coun Name of agent CAS No Identifi- TWA STEL Ceil- Nota- Source try er [mg/ [mg/ ing-C tion m³] m³] [mg/ m³] EU manganese, inorganic 7722-64-7 IOELV 0,05 r 2017/164/ compounds EU IE dusts non-specific OELV 10 i S.I. No. 619 of 2001 IE dusts non-specific OELV 4 r S.I. No. 619 of 2001 IE manganese, inorganic 7722-64-7 OELV 0,2 i S.I. No. 619 compounds of 2001 IE manganese, inorganic 7722-64-7 OELV 0,05 r S.I. No. 619 compounds of 2001 Notation Ceiling-C Ceiling value is a limit value above which exposure should not occur i Inhalable fraction r Respirable fraction STEL Short-term exposure limit: a limit value above which exposure should not occur and which is related to a 15- minute period (unless otherwise specified) TWA Time-weighted average (long-term exposure limit): measured or calculated in relation to a reference period of 8 hours time-weighted average (unless otherwise specified) Human health values Relevant DNELs and other threshold levels Endpoint Threshold Protection goal, Used in Exposure time level route of exposure DNEL 0,2 mg/m³ human, inhalatory worker (industry) chronic - systemic effects Environmental values Relevant PNECs and other threshold levels End- Threshold Organism Environmental com- Exposure time point level partment µg PNEC 0,06 /l aquatic organisms freshwater short-term (single instance) mg PNEC 1,64 /l aquatic organisms sewage treatment plant short-term (single instance) (STP) 8.2 Exposure controls Individual protection measures (personal protective equipment) Eye/face protection Use safety goggle with side protection.
Recommended publications
  • Decolorization of Reactive Orange 16 Via Ferrate(VI) Oxidation Assisted by Sonication
    Turkish Journal of Chemistry Turk J Chem (2017) 41: 577 { 586 http://journals.tubitak.gov.tr/chem/ ⃝c TUB¨ ITAK_ Research Article doi:10.3906/kim-1701-8 Decolorization of reactive orange 16 via ferrate(VI) oxidation assisted by sonication Serkan S¸AHINKAYA_ ∗ Department of Environmental Engineering, Faculty of Engineering and Architecture, Nev¸sehirHacı Bekta¸sVeli University, Nev¸sehir,Turkey Received: 02.01.2017 • Accepted/Published Online: 24.03.2017 • Final Version: 05.09.2017 Abstract: The decolorization of azo dye C.I. reactive orange 16 (RO 16) via ferrate(VI) and sono-ferrate(VI) methods, which is the combination of the ferrate(VI) oxidation method with sonication, has been achieved in the present study. The influences of some important operating parameters, which are the initial pH, the concentration of potassium ferrate(VI) (K 2 FeO 4) and the RO 16 dye, and ultrasonic density (for only the sono-ferrate(VI) method), on the color removal have −1 been investigated. The optimum conditions have been determined as pH = 7 and [K 2 FeO 4 ] = 50 mg L for the −1 −1 individual ferrate(VI) oxidation method and pH = 7 and [K 2 FeO 4 ] = 50 mg L by direct sonication at 0.50 W mL ultrasonic density and 20 kHz fixed frequency for the sono-ferrate(VI) method. The color removal efficiencies were 85% by ferrate(VI) method and 91% by sono-ferrate(VI) method. Kinetic studies were also performed for the decolorization of RO 16 under the optimized conditions at room temperature. It was seen that the oxidative decolorization of RO 16 via the sono-ferrate(VI) method happened more rapidly because of the production of OH • radical through sonication compared to the individual ferrate(VI) method.
    [Show full text]
  • Kinetic Studies on Permanganate Oxidation of Acetophenones Under
    Indi an Journal of Chemistry Vol. 40A, June 2001, pp. 610-612 Kinetic studies on permanganate oxidation of The ketones were further purified by vacuum acetophenones under phase transfer catalysis distillation. The solvents employed were purified by standard methods and doubly distilled water was P S Sheeba & T D Radhakrishnan Nair* always used. The catalysts used were tricapryl­ Department of Chemistry, Calicut University methylammonium chloride (TCMAC) and tetrabutyl­ Calicut University P.O., Kerala 673 635. India ammonium bromide (TBAB). The former has Received 18 October 2000; revised 8 March 2001 relatively larger organic structure (C 10H21 )JN+CH 3Cr compared to the latter (C4 H9) 4N+B(. Kinetic studies on the permanganate oxidation of The solutions containing the permanganate ions in acetopheno_ne and some of its substituents in organic media using the organic solvents were prepared by shaking the techn1que of phase transfer catalysis are reported. aqueous potassium permanganate solution with the Tncaprylmethylammonium chloride and tetrabutylammonium bromide have been used as the phase transfer catalysts. The organic solvents contammg the phase transfer 4 reaction shows first order dependence each on [ketones] and the catalysts as reported elsewhere . The solutions of the [permanganate ions] respectively . The rate coefficients fit well oxidant thus prepared in the organic solvent and the with the Hammett equation and the p-value calculated aorees well substrate in the organic solvent were thermally with the reaction requirements. "' equilibrated (± 0.05°C) at the desired temperature for Potassium permanganate is a powerful oxidizing about half an hour before mixing. Kinetic runs were carried out under pseudo-first order conditions.
    [Show full text]
  • Manufacturing of Potassium Permanganate Kmno4  This Is the Most Important and Well Known Salt of Permanganic Acid
    Manufacturing of Potassium Permanganate KMnO4 This is the most important and well known salt of permanganic acid. It is prepared from the pyrolusite ore. It is prepared by fusing pyrolusite ore either with KOH or K2CO3 in presence of atmospheric oxygen or any other oxidising agent such as KNO3. The mass turns green with the formation of potassium manganate, K2MnO4. 2MnO2 + 4KOH + O2 →2K2MnO4 + 2H2O 2MnO2 + 2K2CO3 + O2 →2K2MnO4 + 2CO2 The fused mass is extracted with water. The solution is now treated with a current of chlorine or ozone or carbon dioxide to convert manganate into permanganate. 2K2MnO4 + Cl2 → 2KMnO4 + 2KCl 2K2MnO4 + H2O + O3 → 2KMnO4 + 2KOH + O2 3K2MnO4 + 2CO2 → 2KMnO4 + MnO2 + 2K2CO3 Now-a-days, the conversion is done electrolytically. It is electrolysed between iron cathode and nickel anode. Dilute alkali solution is taken in the cathodic compartment and potassium manganate solution is taken in the anodic compartment. Both the compartments are separated by a diaphragm. On passing current, the oxygen evolved at anode oxidises manganate into permanganate. At anode: 2K2MnO4 + H2O + O → 2KMnO4 + 2KOH 2- - - MnO4 → MnO4 + e + - At cathode: 2H + 2e → H2 Properties: It is purple coloured crystalline compound. It is fairly soluble in water. When heated alone or with an alkali, it decomposes evolving oxygen. 2KMnO4 → K2MnO4 + MnO2 + O2 4KMnO4 + 4KOH → 4K2MnO4 + 2H2O + O2 On treatment with conc. H2SO4, it forms manganese heptoxide via permanganyl sulphate which decomposes explosively on heating. 2KMnO4+3H2SO4 → 2KHSO4 + (MnO3)2SO4 + 2H2O (MnO3)2SO4 + H2O → Mn2O7 + H2SO4 Mn2O7 → 2MnO2 + 3/2O2 Potassium permanganate is a powerful oxidising agent. A mixture of sulphur, charcoal and KMnO4 forms an explosive powder.
    [Show full text]
  • Experiment: Determination of Manganese in Steel
    p.1 of 4 Chemistry 201 – Winter 2007 Experiment: Determination of Manganese in Steel Manganese (Mn) in steel may be determined upon dissolution as manganese (VII) after oxidation from the manganese oxidation state (II). This procedure calls for three oxidizing agents. Manganese (VII) may be determined spectrophotometrically. During dissolution of the sample with dilute nitric acid to form iron (II) and manganese (II), nitrogen oxide gases are formed. These must be removed, partially by boiling, and the rest with ammonium peroxydisulfate which also removes carbon or other organic matter present. The nitrogen oxides may react with periodic acid which is used to convert manganese to the (VII) oxidation state. Excess peroxydisulfate is decomposed by boiling. The equations are: - + 2+ 3 Mn + 2 NO3 + 8H ---> 3 Mn + 2 NO (g) + 4H2O 2- - 2- + 2 NO2 (g) + S2O8 + 2 H2O ---> 2 NO3 + 2 SO4 + 4 H 2- 2- + 2 S2O8 + 2 H2O + heat ---> 4 SO4 + O2 + 4 H 2+ - - + - 2 Mn + 5 IO4 + 3 H2O ---> 2 MnO4 + 6 H + 5 IO3 NO(colorless gas) + 1/2 O2 (g) <---> NO2 (brown gas) Note: Peroxydisulfate has the required oxidizing potential to change the oxidation state of manganese from (II) to (IV), but the reaction is too slow. Silver could be employed catalytically but the results are too erratic. Periodate oxidizes the manganese to the (VII) state quantitatively and rapidly at the boiling point, and it is advisable to add the sparingly soluble periodate salt in several portions to maintain an excess and to allow for some decomposition of the latter salt at the elevated temperatures.
    [Show full text]
  • Potassium Permanganate MSDS
    He a lt h 2 0 Fire 0 1 0 Re a c t iv it y 0 Pe rs o n a l Pro t e c t io n J Material Safety Data Sheet Potassium permanganate MSDS Section 1: Chemical Product and Company Identification Product Name: Potassium permanganate Contact Information: Catalog Codes: SLP4912, SLP3892, SLP1075 Sciencelab.com, Inc. 14025 Smith Rd. CAS#: 7722-64-7 Houston, Texas 77396 RTECS: SD6475000 US Sales: 1-800-901-7247 International Sales: 1-281-441-4400 TSCA: TSCA 8(b) inventory: Potassium permanganate Order Online: ScienceLab.com CI#: Not available. CHEMTREC (24HR Emergency Telephone), call: Synonym: Potassium Permanganate, Biotech Grade 1-800-424-9300 Chemical Name: Potassium Permanganate International CHEMTREC, call: 1-703-527-3887 Chemical Formula: KMnO4 For non-emergency assistance, call: 1-281-441-4400 Section 2: Composition and Information on Ingredients Composition: Name CAS # % by Weight Potassium permanganate 7722-64-7 100 Toxicological Data on Ingredients: Potassium permanganate, Biotech: ORAL (LD50): Acute: 1090 mg/kg [Rat]. 2157 mg/kg [Mouse]. Section 3: Hazards Identification Potential Acute Health Effects: Hazardous in case of skin contact (irritant), of eye contact (irritant), of ingestion, of inhalation. Slightly hazardous in case of skin contact (permeator). Possibly corrosive to eyes and skin. The amount of tissue damage depends on length of contact. Eye contact can result in corneal damage or blindness. Skin contact can produce inflammation and blistering. Inhalation of dust will produce irritation to gastro-intestinal or respiratory tract, characterized by burning, sneezing and coughing. Severe over-exposure can produce lung damage, choking, unconsciousness or death.
    [Show full text]
  • In Situ Chemical Oxidation of Creosote/Coal Tar Residuals: Experimental and Numerical Investigation
    In situ Chemical Oxidation of Creosote/Coal Tar Residuals: Experimental and Numerical Investigation by Steven Philip Forsey A thesis presented to the University of Waterloo in fulfillment of the thesis requirement of the degree of Doctor of Philosophy in Earth Sciences Waterloo, Ontario, Canada, 2004 ©Steven Philip Forsey 2004 I herby declare that I am the sole author of this thesis. This is a true copy of the thesis, including any required final version, as accepted by my examiners. I understand that my thesis may be made electronically available to the public Steven Forsey ii Abstract Coal tar, coal tar creosote and oily wastes are often present as subsurface contaminants that may migrate below the water table, leaving a widely distributed residual source of contaminants leaching to the ground water. In situ chemical oxidation is a potentially viable technology for the remediation of aquifers contaminated with creosote and coal tars. The oxidant of choice would be flushed through the contaminated area to oxidize aqueous contaminants and enhance the mass transfer of contaminants from the oil phase. A series of batch and column experiments were performed to assess the ability of a chemical oxidizing reagent to oxidize creosote compounds and to increase mass transfer rates. Results from the column experiments were then simulated using a reactive transport model that considered 12 different creosote compounds undergoing dissolution, oxidation and advective-dispersive transport. Three strong chemical oxidizing reagents, Fenton’s Reagent, potassium persulfate with ferrous ions, and potassium permanganate were tested with batch experiments to determine their reactivity towards creosote compounds. All three reagents successfully decomposed aqueous creosote compounds and were able to reduce the mass of the monitored creosote compounds within the oil phase.
    [Show full text]
  • Chemical Incompatibilities
    Chemical Incompatibilities Incompatibilities Chromic acid, nitric acid, hydroxyl compounds, ethylene glycol, Acetic acid perchloric acid, peroxides, permanganates Acetylene Chlorine, bromine, copper, fluorine, silver, mercury Acetone Concentrated nitric and sulfuric acid mixtures Alkali and alkaline earth metals (such as Water, carbon tetrachloride or other chlorinated hydrocarbons, powdered aluminum or magnesium, calcium, carbon dioxide, halogens lithium, sodium, potassium) Mercury (in manometers, for example), chlorine, calcium Ammonia (anhydrous) hypochlorite, iodine, bromine, hydrofluoric acid (anhydrous) Acids, powdered metals, flammable liquids, chlorates, nitrites, Ammonium nitrate sulfur, finely divided organic combustible materials Aniline Nitric acid, hydrogen peroxide Arsenical materials Any reducing agent Azides Acids Bromine See chlorine Calcium oxide Water Carbon (activated) Calcium hypochlorite, all oxidizing agents Carbon tetrachloride Sodium Ammonium salts, acids, powdered metals, sulfur, finely divided Chlorates organic or combustible materials Acetic acid, naphthalene, camphor, glycerol, alcohol, flammable Chromic acid and chromium liquids in general Ammonia, acetylene, butadiene, butane, methane, propane (or Chlorine other petroleum gases), hydrogen, sodium carbide, benzene, finely divided metals, turpentine Chlorine dioxide Ammonia, methane, phosphine, hydrogen sulfide Copper Acetylene, hydrogen peroxide Cumene hydroperoxide Acids (organic or inorganic) Cyanides Acids Ammonium nitrate, chromic acid, hydrogen peroxide,
    [Show full text]
  • Process Development for Permanganate Addition During Oxidative Leaching of Hanford Tank Sludge Simulants
    PNNL-16794 WTP-RPT-164, Rev 0 Process Development for Permanganate Addition During Oxidative Leaching of Hanford Tank Sludge Simulants B. M. Rapko G. J. Lumetta J. R. Deschane R. A. Peterson October 2007 Prepared for the U.S. Department of Energy under Contract DE-AC05-76RL01830 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor Battelle Memorial Institute, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORY operated by BATTELLE for the UNITED STATES DEPARTMENT OF ENERGY under Contract DE-ACO5-76RL01830 PNNL-16794 WTP-RPT-164, Rev 0 Process Development for Permanganate Addition During Oxidative Leaching of Hanford Tank Sludge Simulants B. M. Rapko G. J. Lumetta J. R. Deschane R. A. Peterson October 2007 Test specification: 24590-PTF-TSP-RT-06-002, Rev. 0 Test Plan: TP-RPP-WTP-453, Rev. 0, and ICN-TP-RPP-WTP-453.1 Test exceptions: 24590-WTP-TEF-RT-07-00002 R&T focus area: Pretreatment Test scoping statement(s): None Pacific Northwest National Laboratory Richland, Washington 99352 Contents Acronyms....................................................................................................................................................
    [Show full text]
  • Sodium Chloride - Analytical Standard
    Sodium Chloride - Analytical Standard Determination of Nitrite Permanganate / Thiosulphate Titrimetric Method EUsalt/AS 001-2005 Former numbering: ECSS/CN 90-1973 & ESPA/CN-E-112-199 www.eusalt.com Determination of nitrite Permanganate/Thiosulphate Titrimetric Method EUsalt/AS 001-2005 1. SCOPE AND FIELD OF APPLICATION 3.5. Sodium thiosulphate, C(Na2S2O3) = 0.1 mol/l, standard volumetric solution The present EUsalt Analytical Standard describes a titrimetric method for the determination of 3.6. Starch solution, 2 g/l nitrites in nitrited sodium chloride. The method is Prepare this solution at the time of use from applicable to products of nitrite content soluble starch. (expressed as sodium nitrite) equal to or greater than 0.15 g per kilogram of salt. 4. APPARATUS Usual laboratory equipment. 2. PRINCIPLE Dissolution of the sample in water. 5. SAMPLING AND SAMPLES Oxidation of nitrite to nitrate with potassium A test sample of 500 g should be taken for permanganate. analysis, ensuring it is representative of the whole batch. Addition of potassium iodide and titration of the liberated free iodine corresponding to the excess 6. PROCEDURE of potassium permanganate with sodium 6.1. Test portion thiosulphate using starch as indicator. Weigh, to the nearest 0.1 g, about 50 g of the test 3. REAGENTS sample. Unless otherwise stated, use only reagents of 6.2. Test solution recognized analytical grade and only distilled Transfer the test portion (6.1.) and 300 ml of water or water of equivalent purity. water into a 500 ml volumetric flask, stir to dissolve, dilute to the mark and mix.
    [Show full text]
  • Permanganate Hazard Summary Identification
    Common Name: AMMONIUM PERMANGANATE CAS Number: 13446-10-1 RTK Substance number: 0110 DOT Number: UN 1482 Date: February 1988 Revision: August 2000 ----------------------------------------------------------------------- ----------------------------------------------------------------------- HAZARD SUMMARY WORKPLACE EXPOSURE LIMITS * Ammonium Permanganate can affect you when breathed No occupational exposure limits have been established for in. Ammonium Permanganate. This does not mean that this * Contact can irritate the skin and eyes. substance is not harmful. Safe work practices should always * Breathing Ammonium Permanganate can irritate the be followed. nose, throat and lungs. * Ammonium Permanganate is a HIGHLY REACTIVE WAYS OF REDUCING EXPOSURE CHEMICAL and a DANGEROUS EXPLOSION * Where possible, enclose operations and use local exhaust HAZARD. ventilation at the site of chemical release. If local exhaust ventilation or enclosure is not used, respirators should be IDENTIFICATION worn. Ammonium Permanganate is a violet-brown or dark purple, * Wear protective work clothing. crystalline (sand-like) solid. * Wash thoroughly immediately after exposure to Ammonium Permanganate and at the end of the REASON FOR CITATION workshift. * Ammonium Permanganate is on the Hazardous * Post hazard and warning information in the work area. In Substance List because it is cited by DOT and NFPA. addition, as part of an ongoing education and training * This chemical is on the Special Health Hazard Substance effort, communicate all information on the health and List because it is REACTIVE. safety hazards of Ammonium Permanganate to * Definitions are provided on page 5. potentially exposed workers. HOW TO DETERMINE IF YOU ARE BEING EXPOSED The New Jersey Right to Know Act requires most employers to label chemicals in the workplace and requires public employers to provide their employees with information and training concerning chemical hazards and controls.
    [Show full text]
  • Sodium Nitrite
    SODIUM NITRITE Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 17th JECFA (1973), published in FNP 4 (1978) and in FNP 52 (1992). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-0.06 mg/kg bw was established at 44th JECFA (1995). Nitrite should not be used for infants below 3 months SYNONYMS INS No. 250 DEFINITION Chemical names Sodium nitrite C.A.S. number 7632-00-0 Chemical formula NaNO2 Formula weight 69.00 Assay Not less than 97.0% on the dried basis DESCRIPTION White or slightly yellow, hygroscopic and deliquescent granules, powder, or opaque, fused masses of sticks FUNCTIONAL USES Antimicrobial preservative, colour fixative CHARACTERISTICS IDENTIFICATION Solubility (Vol. 4) Freely soluble in water, sparingly soluble in ethanol Test for sodium (Vol. 4) Passes test Test for nitrite (Vol. 4) Passes test PURITY Loss on drying (Vol. 4) Not more than 0.25% (over silica gel, 4 h) Lead (Vol. 4) Not more than 2 mg/kg Determine using an atomic absorption technique appropriate to the specified level. The selection of sample size and method of sample preparation may be based on the principles of the method described in Volume 4, “Instrumental Methods.” METHOD OF Weigh, to the nearest mg, 1 g of the dried sample. Transfer to a 100 ml ASSAY volumetric flask and dissolve in water diluting to the mark. Pipette 10.0 ml of this solution into a mixture of 50.0 ml of 0.1N potassium permanganate, 100 ml of water and 5 ml of sulfuric acid, keeping the tip of the pipette well below the surface of the liquid.
    [Show full text]
  • Chitosan Encapsulation of Ferratevi for Controlled Release to Water
    www.nature.com/scientificreports OPEN Chitosan Encapsulation of FerrateVI for Controlled Release to Water:Mechanistic Insights and Degradation of Organic Contaminant Bo-Yen Chen1, Hsuen-Wen Kuo1, Virender K. Sharma 2 & Walter Den3* VI 2− VI Tetraoxy-anion of iron in +6 oxidation state (Fe O4 , Fe ), commonly called ferrate, has shown tremendous potential as a green oxidative agent for decontaminating water and air. Encapsulation of solid potassium salt of ferrate (K2FeO4) circumvents the inherent drawbacks of the instability of ferrate under humid conditions. In the encapsulated strategy, controlled release without exposing the solid ferrate to the humid environment avoids self-decomposition of the oxidant by water in the air, and the ferrate is mostly used to decontaminate water efciently. This study demonstrated the formulation of oxidative microcapsules with natural materials present in chitosan, whose release rate of the core material can be controlled by the type of intermediate hydrocarbon layer and the pH-dependent swelling of chitosan shell. The pH played a pivotal role in swelling chitosan shell and releasing the core oxidant. In a strong acidic solution, chitosan tended to swell quickly and release FeVI at a faster rate than under neutral conditions. Additionally, among the several long-chain hydrocarbon compounds, oleic acid exhibited the strongest “locking” efect when applied as the intermediate layer, giving rise to the slow release of FeVI. Coconut oil and mineral oil, in comparison, allowed FeVI to penetrate the layer within shorter lengths of time and showed comparable degrees of degradation of target contaminant, methylene orange, under ambient temperature and near-neutral conditions.
    [Show full text]