CSA 1300Z CSA 2300Z Commercial Series Amplifer
Total Page:16
File Type:pdf, Size:1020Kb
JBL Commercial Series CSA 1300Z CSA 2300Z Commercial Series Amplifer Operation Manual CSA 1300Z CSA 2300Z Contents Important Safety Information .......................................................................... 3 JBL DECLARATION OF CONFORMITY .......................................................... 5 1.0 Welcome ................................................................................................... 7 1.1 Features ................................................................................................. 7 1.2 Front Control Panels and Indicators ...................................................... 8 1.3 Rear Panel Controls and Connectors..................................................... 9 2.0 Setup ........................................................................................................10 2.1 Unpacking Your Amplifier ......................................................................10 2.2 Installing Your Amplifier .........................................................................10 2.3 Ensuring Proper Cooling .......................................................................12 2.4 Choosing Input Wire and Connectors ...................................................12 2.5 Output Wiring and Connectors .............................................................13 2.6 Wiring Your Audio System .....................................................................14 2.7 Connecting to AC Mains .....................................................................15 2.8 Protecting Your Speakers .....................................................................15 2.9 Startup Procedure .................................................................................15 3.0 Operation ..................................................................................................16 3.1 Precautions .............................................................................................16 3.2 70V/100V Switch ...................................................................................17 3.3 Remote Control Capability ......................................................................17 4.0 Troubleshooting ........................................................................................18 Appendix A: Target Performance Specifications ........................................ 19 Appendix B: Remote RS232 Control .......................................................... 20 Appendix C: Contact Information ............................................................... 22 This manual does not include all of the details of design, production, or variation of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have occurred. Trademark Notice: JBL is registered trademark of JBL International. CROWN and DRIVECORE are registered trademarks of Crown Audio. Other trademarks are the property of their respective owners. © 2016 JBL Commercial, 8760 South Sandy Parkway, Sandy, UT. All Rights Reserved. 2 IMPORTANT SAFETY INFORMATION WARNING FOR YOUR PROTECTION READ THESE INSTRUCTIONS: WARNING KEEP THESE INSTRUCTIONS RISK OF ELECTRIC SHOCK DO NOT OPEN HEED ALL WARNINGS AVERTISSEMENT: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR FOLLOW ALL INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING LIQUID AND NO OBJECT FILLED WITH LIQUID, SUCH The symbols shown above are internationally accepted symbols AS VASES, SHALL BE PLACED ON THE APPARATUS that warn of potential hazards with electrical products. The light- CLEAN ONLY WITH A DRY CLOTH. ning flash with arrow point in an equilateral triangle means that there are dangerous voltages present within the unit. The exclama- DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN tion point in an equilateral triangle indicates that it is necessary for ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS. the user to refer to the owner’s manual. DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTERS, STOVES, OR OTHER APPARATUS These symbols warn that there are no user serviceable parts inside (INCLUDING AMPLIFIERS) THAT PRODUCE HEAT. the unit. Do not open the unit. Do not attempt to service the unit ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE yourself. Refer all servicing to qualified personnel. Opening the MANUFACTURER. chassis for any reason will void the manufacturer’s warranty. Do not UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN get the unit wet. If liquid is spilled on the unit, shut it off immediately UNUSED FOR LONG PERIODS OF TIME. and take it to a dealer for service. Disconnect the unit during storms to prevent damage. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong are provided for your safety. If SAFETY INSTRUCTIONS the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet. NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER Protect the power cord from being walked on or pinched particularly CORD. at plugs, convenience receptacles, and the point where they exit from the apparatus. WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION. Use only with the cart stand, tripod bracket, or table specified by The cores in the mains lead are colored in accordance with the following code: the manufacture, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid GREEN and YELLOW - Earth BLUE - Neutral BROWN - Live injury from tip-over. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any As colors of the cores in the mains lead of this appliance may not cor- way, such as power-supply cord or plug is damaged, liquid has been respond with the colored markings identifying the terminals in your plug, spilled or objects have fallen into the apparatus, the apparatus has proceed as follows: been exposed to rain or moisture, does not operate normally, or has been dropped. • The core which is colored green and yellow must be connected to the terminal in the plug marked with the letter E, or with the earth symbol, or colored green, or green and yellow. • The core which is colored blue must be connected to the terminal marked N or colored black. POWER ON/OFF SWITCH: For products provided with a power • The core which is colored brown must be connected to the terminal switch, the power switch DOES NOT break the connection from the marked L or colored red. mains. This equipment may require the use of a different line cord, attachment MAINS DISCONNECT: The plug shall remain readily operable. For rack-mount or installation where plug is not accessible, an all-pole plug, or both, depending on the available power source at installation. If mains switch with a contact separation of at least 3 mm in each the attachment plug needs to be changed, refer servicing to qualified ser- pole shall be incorporated into the electrical installation of the rack vice personnel who should refer to the table below. The green/yellow wire or building. shall be connected directly to the units chassis. WIRE COLOR FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE CONDUCTOR RECEPTACLE: Replace fuse with same type and rating only. Normal Alt L LIVE BROWN BLACK MULTIPLE-INPUT VOLTAGE: This equipment may require the use N NEUTRAL BLUE WHITE of a different line cord, attachment plug, or both, depending on the available power source at installation. Connect this equipment only to E EARTH GND GREEN/YEL GREEN the power source indicated on the equipment rear panel. To reduce WARNING: If the ground is defeated, certain fault conditions in the unit or in the risk of fire or electric shock, refer servicing to qualified service the system to which it is connected can result in full line voltage between personnel or equivalent. chassis and earth ground. Severe injury or death can then result if the If connected to 240V supply, a suitable CSA/UL certified power cord shall chassis and earth ground are touched simultaneously. be used for this supply. 3 IMPORTANT SAFETY INFORMATION U.K. MAINS PLUG WARNING If you want to dispose this product, do not mix it with gen- eral household waste. There is a separate collection system for used electronic products in accordance with legislation A molded mains plug that has been cut off from the cord is that requires proper treatment, recovery and recycling. unsafe. Discard the mains plug at a suitable disposal facility. NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT Private household in the 25 member states of the EU, in Switzerland and Norway may return their used electronic products free of charge to A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER designated collection facilities or to a retailer (if you purchase a similar SOCKET. Do not use the mains plug without the fuse cover in new one). place. Replacement fuse covers can be obtained from your For Countries not mentioned above, please contact your local authorities local retailer. Replacement fuses are 13 amps and MUST be for a correct method of