Telecom / Modular - Premise Wiring Tutorial 44 Telecom / Modular - Premise Wiring Tutorial What is Premise Wiring? How is Premise Wiring used? Where is Premise Wiring used? Premise Wiring is the cabling, connectors and Premise Wiring is made up of vertical and Premise wiring can be found in just about all accessories that are used to connect LAN (Local horizontal cable runs from a central location public and private buildings, including educational Area Network) and phone equipment inside a throughout buildings to individual desktops. and government buildings as well as in many commercial building. newer homes. Typical LAN Premise Wiring Typical Telecommunications Closet Wiring Notes: Horizontal runs to 1. Category 5e / 6 unshielded office drops are twisted pair is the norm. Use connected permanently 4 pair solid conductor inside to the rear of Category the walls, 4 pair stranded for 5e / 6 patch panels. patch cords. Plenum rated cabling may be necessary Category 5e / 6 patch depending upon fire codes panels and patch cords in your area. are used to connect to 2. Maximum distance for a network equipment. horizontal run is 90m (solid conductor) plus an additional Network Equipment 10m (stranded conductor) for patching. 19" rack or cabinet. 3. Fiber is the common choice for backbone wiring. It is also recommended for horizontal runs over 100m. Approximately 70% of network downtime is due to faulty cables Quality Components are the building blocks of a reliable network This is an example of our competitor's inferior copper Cable clad aluminum cable design. Many low cost telecom / modular cables use copper clad aluminum or copper clad steel. Aluminum and steel have much higher resistance than copper, resulting in increased data loss and low transmission speeds. L-com uses only pure copper conductors on its cables. Additionally, cable jackets can be made with less fireproofing materials than claimed and in some cases the writing on the jacket might state 24 AWG but is actually made from 25 or 26 AWG wire. Connectors Some competitor's connectors use only a gold flash where L-com ensures 50 microinches (1.27µm) or better of gold flash on our connectors. Gold flash on connectors quickly rubs off, especially for patch cables. This can result in a measurably slower network and even dropped connectivity. Gold flash on competitors RJ45 contact has deteriorated, L-com connectors with 50 microinches (1.27µm) of gold degrading connectivity. do not degrade. To view the entire article concerning counterfeit and low quality telecom / modular cables visit our website: L-com.com/CableTest L-com.com | 800-343-1455 | [email protected] TELECOM / MODULAR 45 Ethernet Cable Applications Download this helpful chart at L-com.com/EthernetCableGuide CONSTRUCTION MATERIAL PVC UTP Very common jacket and over mold compound used in Used in controlled environments with very basic small office / home office (SOHO), small to medium little to no EMI / RFI. Used in home, small business (SMB) and Enterprise network applications. PVC office and Enterprise business networks. burns rapidly and releases hazardous gases when burned. Applications consist of general open space connectivity (not used in walls or ceilings). Shielded LSZH For environments where EMI / RFI is Low Smoke Zero Halogen cables produce very little smoke present, such as near motors, generators when burned and release no halogen compounds including and other "noise" generating machines. Fluorine, Chlorine, and Bromine. This type of cabling is typically used in confined spaces where human lives and expensive communications equipment reside. LSZH is used on ships, submarines, aircraft, terrestrial vehicles etc. Double Shielded Used in extremely high EMI / RFI Plenum environments such as factories and Plenum cabling is used in buildings in the plenum air space processing plants where “noise” usually above ceiling tiles or in the plenum airspace under generating equipment including the flooring in a server room or data closet. Plenum cables generators, power transmission lines, will self extinguish and not re-ignite. and electric motors are present. PUR/TPE PUR (polyurethane) and TPE (thermoplastic elastomer) High Flex cabling are typically used in harsh or Industrial Ethernet Used in continuous motion applications networking applications where the presence of petroleum such as a robot arm control cable in a based contaminants, UV rays, and physical impacts manufacturing environment. occur. Applications include oil refineries, factory floor, manufacturing, processing industries (food and chemical) etc. Telecom / Modular Connectors MALE PLUGS Modular Modular Modular Modular Modular 10 Modular Modular Modular Modular RJ45 Modular (6x2) (8x2) (8x4) (8x6) Pos. (10x10) RJ11 (6x4) RJ12 (6x6) RJ45 (8x8) (8x8 Keyed) MMJ (6x6) FEMALE JACKS Common Wiring Standards for Data Communications PR 2 PR 3 RJ45 Plug (8x8) There are two common wiring standards for LAN wiring. When buying PR 3 PR 1 PR 4 PR 2 PR 1 PR 4 components such as jacks or patch panels, be sure to specify if you need EIA568A or EIA568B. RJ45 1 8 12345678 Jack 12345678 (8x8) EIA / TIA568A EIA / TIA568B WIRING AT&T 258A WIRING 46 TELECOM / MODULAR ~ Category 6 LSZH and PVC, Shielded and Unshielded Patch Cords Premium Category 6 RJ45 to RJ45 Shielded Patch Cords Category 6 has become the de facto standard when installing Category 6 Patch Cords Category 6 Stranded Drain Wire new network cabling. With high bandwidth applications on the 4 Pair Cable rise and Ethernet network deployments venturing into new EIA568 areas such as factory environments, the need for shielded Zero Halogen Four 26 AWG Category 6 cable assemblies has also increased. L-com has 1 2 3 456 7 8 S or PVC Jacket Stranded Pairs stepped up to this new demand and created a line of high Twisted Pair Pinning: 1 & 2, 3 & 6, 4 & 5, 7 & 8 performance Category 6 patch cords that feature a 100% foil Aluminum Mylar Shield shield and the option of either a PVC or Zero Halogen jacket. Ordering is easy, add the desired color code to the part number. Ex: TRD695DSZ-BLK-1. *Note: No suffix necessary for gray TRD695SZ assemblies. Item # Description Length 1-9 10-24 25-99 100+ Best Seller Category 6 Double Shielded LSZH 26 AWG Stranded Patch Cords TRD695DSZ- __-1 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 1.0ft (0.3m) 13.36 12.82 12.29 CALL -GRY TRD695DSZ- __-2 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 2.0ft (0.6m) 14.50 13.92 13.34 CALL *--- TRD695DSZ- __-3 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 3.0ft (0.9m) 15.64 15.01 14.39 CALL TRD695DSZ-GRY TRD695DSZ- __-5 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 5.0ft (1.5m) 17.92 17.20 16.48 CALL TRD695SZ TRD695DSZ- __-7 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 7.0ft (2.1m) 20.20 19.39 18.58 CALL TRD695DSZ- __-10 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 10.0ft (3.0m) 23.61 22.67 21.73 CALL TRD695DSZ- __-15 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 15.0ft (4.6m) 29.31 28.14 26.97 CALL TRD695DSZ- __-25 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 25.0ft (7.6m) 40.71 39.08 37.46 CALL TRD695DSZ- __-50 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 50.0ft (15.2m) 69.21 66.44 63.67 CALL TRD695DSZ- __-75 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 75.0ft (22.9m) 97.70 93.80 89.89 CALL TRD695DSZ- __-100 Double Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 100.0ft (30.4m) 126.20 121.15 116.10 CALL -BLK BLK Category 6 Shielded Patch Cords with LSZH Jacket TRD695DSZ-BLK This series features a LSZH jacket and a 100% foil shield. The four pair 26 AWG stranded Cat6 cable is terminated with L-com's unique shielded TRD695SZBLK Cat6 plugs, with a fully crimped shield termination that doubles as a strain relief. TRD695SZ __-1 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 1.0ft (0.3m) 9.21 8.94 8.66 CALL TRD695SZ __-2 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 2.0ft (0.6m) 10.56 10.24 9.93 CALL TRD695SZ __-3 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 3.0ft (0.9m) 12.01 11.65 11.29 CALL TRD695SZ __-5 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 5.0ft (1.5m) 14.81 14.36 13.92 CALL TRD695SZ __-7 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 7.0ft (2.1m) 17.61 17.08 16.55 CALL TRD695SZ __-10 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 10.0ft (3.0m) 21.75 21.10 20.44 CALL -RED TRD695SZ __-15 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 15.0ft (4.6m) 28.80 27.93 27.07 CALL R TRD695SZ __-25 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 25.0ft (7.6m) 42.78 41.50 40.22 CALL TRD695DSZ-RED TRD695SZ __-50 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 50.0ft (15.2m) 77.70 75.37 73.04 CALL TRD695SZR TRD695SZ __-75 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 75.0ft (22.9m) 112.73 109.35 105.96 CALL TRD695SZ __-100 Shielded Cat6 LSZH Patch Cord, RJ45 / RJ45 100.0ft (30.4m) 147.65 143.22 138.79 CALL Category 6 Shielded Patch Cords with PVC Jacket TRD695SCR-BLK TRD695SCR-BL TRD695SCR-GR TRD695SCR-R TRD695SCR-Y TRD855SCR BLK BL GR R Y *--- Ordering is easy, add the desired color code to the part number. Ex: TRD695SCR-BLK-3 *Note: No suffix necessary for gray assemblies. Item # Description Length 1-9 10-24 25-99 100+ TRD695SCR-__-1 Shielded Category 6 Patch Cord, RJ45 / RJ45 1.0ft (0.3m) 8.28 8.03 7.78 CALL TRD695SCR-__-2 Shielded Category 6 Patch Cord, RJ45 / RJ45 2.0ft (0.6m) 9.11 8.83 8.56 CALL TRD695SCR-__-3 Shielded Category 6 Patch Cord, RJ45 / RJ45 3.0ft (0.9m) 9.83 9.54 9.24 CALL TRD695SCR-__-5 Shielded Category 6 Patch Cord, RJ45 / RJ45 5.0ft (1.5m) 11.39 11.05 10.70 CALL TRD695SCR-__-7 Shielded Category 6 Patch Cord, RJ45 / RJ45 7.0ft (2.1m) 12.94 12.55 12.17 CALL TRD695SCR-__-10 Shielded
Recommended publications
  • 1) What Is the Name of an Ethernet Cable That Contains Two
    1) What is the name of an Ethernet cable that contains two electrical conductors ? A coaxial cable 2) What are the names of the two common conditions that degrade the signals on c opper-based cables? Crosstal and attenuation 3) Which topology requires the use of terminators? Bus 4) Which of the following topologies is implemented only logically, not physical ly? Ring 5) How many wire pairs are actually used on a typical UTP Ethernet network? Two 6) What is the name of the process of building a frame around network layer info rmation? Data encapsulation 7) Which of the connectors on a network interface adapter transmits data in para llel? The System bus connector 8) Which two of the following hardware resources do network interface adapters a lways require? I/O port address and IRQ 9) What is the name of the process by which a network interface adapter determin es when it should transmit its data over the network? Media Access Control 10) Which bus type is preferred for a NIC that will be connected to a Fast Ether net network? PCI 11) A passive hub does not do which of the following? Transmit management information using SNMP 12) To connect two Ethernet hubs together, you must do which of the following? Connect the uplink port in one hub to a standard port on the other 13) Which term describes a port in a Token Ring MAU that is not part of the ring ? Intelligent 14) A hub that functions as a repeater inhibits the effect of____________? Attenuation 15) You can use which of the following to connect two Ethernet computers togethe r using UTP
    [Show full text]
  • Gigabit Ethernet - CH 3 - Ethernet, Fast Ethernet, and Gigabit Ethern
    Switched, Fast, and Gigabit Ethernet - CH 3 - Ethernet, Fast Ethernet, and Gigabit Ethern.. Page 1 of 36 [Figures are not included in this sample chapter] Switched, Fast, and Gigabit Ethernet - 3 - Ethernet, Fast Ethernet, and Gigabit Ethernet Standards This chapter discusses the theory and standards of the three versions of Ethernet around today: regular 10Mbps Ethernet, 100Mbps Fast Ethernet, and 1000Mbps Gigabit Ethernet. The goal of this chapter is to educate you as a LAN manager or IT professional about essential differences between shared 10Mbps Ethernet and these newer technologies. This chapter focuses on aspects of Fast Ethernet and Gigabit Ethernet that are relevant to you and doesn’t get into too much technical detail. Read this chapter and the following two (Chapter 4, "Layer 2 Ethernet Switching," and Chapter 5, "VLANs and Layer 3 Switching") together. This chapter focuses on the different Ethernet MAC and PHY standards, as well as repeaters, also known as hubs. Chapter 4 examines Ethernet bridging, also known as Layer 2 switching. Chapter 5 discusses VLANs, some basics of routing, and Layer 3 switching. These three chapters serve as a precursor to the second half of this book, namely the hands-on implementation in Chapters 8 through 12. After you understand the key differences between yesterday’s shared Ethernet and today’s Switched, Fast, and Gigabit Ethernet, evaluating products and building a network with these products should be relatively straightforward. The chapter is split into seven sections: l "Ethernet and the OSI Reference Model" discusses the OSI Reference Model and how Ethernet relates to the physical (PHY) and Media Access Control (MAC) layers of the OSI model.
    [Show full text]
  • North American Company Profiles 8X8
    North American Company Profiles 8x8 8X8 8x8, Inc. 2445 Mission College Boulevard Santa Clara, California 95054 Telephone: (408) 727-1885 Fax: (408) 980-0432 Web Site: www.8x8.com Email: [email protected] Fabless IC Supplier Regional Headquarters/Representative Locations Europe: 8x8, Inc. • Bucks, England U.K. Telephone: (44) (1628) 402800 • Fax: (44) (1628) 402829 Financial History ($M), Fiscal Year Ends March 31 1992 1993 1994 1995 1996 1997 1998 Sales 36 31 34 20 29 19 50 Net Income 5 (1) (0.3) (6) (3) (14) 4 R&D Expenditures 7 7 7 8 8 11 12 Capital Expenditures — — — — 1 1 1 Employees 114 100 105 110 81 100 100 Ownership: Publicly held. NASDAQ: EGHT. Company Overview and Strategy 8x8, Inc. is a worldwide leader in the development, manufacture and deployment of an advanced Visual Information Architecture (VIA) encompassing A/V compression/decompression silicon, software, subsystems, and consumer appliances for video telephony, videoconferencing, and video multimedia applications. 8x8, Inc. was founded in 1987. The “8x8” refers to the company’s core technology, which is based upon Discrete Cosine Transform (DCT) image compression and decompression. In DCT, 8-pixel by 8-pixel blocks of image data form the fundamental processing unit. 2-1 8x8 North American Company Profiles Management Paul Voois Chairman and Chief Executive Officer Keith Barraclough President and Chief Operating Officer Bryan Martin Vice President, Engineering and Chief Technical Officer Sandra Abbott Vice President, Finance and Chief Financial Officer Chris McNiffe Vice President, Marketing and Sales Chris Peters Vice President, Sales Michael Noonen Vice President, Business Development Samuel Wang Vice President, Process Technology David Harper Vice President, European Operations Brett Byers Vice President, General Counsel and Investor Relations Products and Processes 8x8 has developed a Video Information Architecture (VIA) incorporating programmable integrated circuits (ICs) and compression/decompression algorithms (codecs) for audio/video communications.
    [Show full text]
  • B-1 APPENDIX B DESCRIPTION of SELECTED COMPETITORS This
    APPENDIX B DESCRIPTION OF SELECTED COMPETITORS This Appendix provides general descriptions of selected competitors for telecommunications services in a number of categories: ILECs/IXCs (other than BellSouth and AT&T); other network providers; CLECs; wireless carriers (other than Cingular); cable providers; system integrators; equipment vendors and value-added resellers; other VoIP service providers; fixed wireless broadband providers; and foreign-based carriers. Incumbent Local Exchange Carriers (ILECs) / Inter-Exchange Carriers (IXCs) With its acquisition of MCI, Verizon is an even stronger competitor for telecommunications services both for enterprise and mass market customers, combining MCI’s robust national and international IP network with one of the nation’s largest cellular and broadband networks. Verizon Business became the company’s new business unit combining the operations of the former Verizon Enterprise Solutions Group and MCI to provide a comprehensive portfolio of end-to-end communications and IP solutions to business and government customers.1 Verizon Business has one of the largest and most interconnected IP 1 Press Release, Verizon, Verizon Business, New Global Communications Provider, Opens for Business Worldwide; Launches Integrated Product Portfolio and Advertising Campaign (Jan. 23, 2006), available at http://newscenter.verizon.com/proactive/newsroom/release.vtml?id=93195; Press Release, Verizon, Verizon Business, New Global Communications Provider, Opens for Business Worldwide; Launches Integrated Product Portfolio and Advertising Campaign (Jan. 23, 2006), available at http://newscenter.verizon.com/proactive/newsroom/release.vtml?id=93195 (“Verizon Business' Fortune 500 customers include Boeing, CSX, and McDonald's among others. The company manages some of the world's most complex and sophisticated networks with some of the highest performance commitments available today for customers including NASDAQ and the Federal Aviation Administration .
    [Show full text]
  • U N * ^ Ms International
    INFORMATION TO USERS Til is reproduction was made from a copy of a document sent to us for microfilming. While the most advanced technology has been used to photograph and reproduce this document, the quality of the reproduction is heavily dependent upon the quality of the material submitted. The following explanation of techniques is provided to help clarify markings or notations which may appear on this reproduction. 1. The sign or “target” for pages apparently lacking from the document photographed is “ Missing Page(s)". If it was possible to obtain the missing page(s) or section, they are spliced into the film along with adjacent pages. This may have necessitated cutting through an image and duplicating adjacent pages to assure com plete co n tin u ity. 2 . When an image on the film is obliterated with a round black mark, it is an indication of either blurred copy because of movement during exposure, duplicate copy, or copyrighted materials that should not have been filmed. For blurred pages, a good image of the page can be found in the adjacent frame. If copyrighted materials were deleted, a target note will appear listing the pages in the adjacent frame. ,V When a map, drawing or chart, etc.. is part of the material being photographed, a definite method of "sectioning" the material has been followed. It is customary to begin filming at the upper left hand corner of a large sheet and to continue from left to right in equal sections with small overlaps. It' necessary, sectioning is continued again beginning below the first row and continuing 011 until complete.
    [Show full text]
  • Datacomm Products and Equipment Catalog
    DataComm Products and Equipment Catalog IDEAL DataComm 112060_DataComm08_COVER.indd2060_DataComm08_COVER.indd 2 11/8/08/8/08 99:41:29:41:29 AAMM The way every job should be IDEAL DataComm is dedicated to helping low voltage/datacomm professionals keep networks up and running. The system of products we have thoughtfully crafted ensures the highest-quality terminations with the ease-of-use you would expect from IDEAL. Our DataComm line includes a system solution for paired conductor, coax and fiber optic cabling. www.idealindustries.com Paired Conductor Products Wire Cutters . A-2 A Wire Strippers . .A-2 Crimp Tools . A-4 Punch Down Tools . A-5 Tool and Connector Kits . A-5 Wall Plates . A-9 Cables . .A-10 Connectors . A-10 Coaxial Termination Products Tool Selection Chart . B-2 B Wire Cutters . B-3 Wire Strippers . B-3 Crimp Tools . B-4 Compression Tools . .B-6 Connectors . B-7 Splitters . .B-8 Wall Plates . B-8 Tool and Connector Kits . B-9 BNC Coaxial Connectors . .B-12 Fiber Optic Products Wire Strippers . C-2 C Fiber Optic Accessories . C-3 Table of Contents Table Test Equipment Qualification Testers . .D-2 D Certification Testers . D-4 Hand-Held Testers . D-7 Related Products Resources . E-1 E Multi Media Installation Guide . .E-3 Technical Information . .E-12 Residential Coax Application Guide . .E-13 Index Alphabetical Index . F-1 F Catalog Number Index . F-3 For applicable GSA Contracts — contact IDEAL at 800-947-3614 New Products Mini Coax Stripper Grounding Block Q Adjustable stripper for Q Solid zinc alloy, mini coax cable nickel plated and Page B-3 chromate finished Page B-8 OmniSeal™ Pro Compression Tools Q Compression tools now offer additional features and increased connector Compression Connector compatibility Installation Kit Page B-6 Q Three tools in one handy pouch that clips easily to your belt.
    [Show full text]
  • Lan.Wiring.Jim.Trulove.Pdf
    LAN Wiring This page intentionally left blank LAN Wiring Third Edition James Trulove McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New Delhi San Juan Seoul Singapore Sydney Toronto Copyright © 2006 by James Trulove. All rights reserved. Manufactured in the United States of America. Except as permit- ted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of the publisher. 0-07-148345-4 The material in this eBook also appears in the print version of this title: 0-07-145975-8. All trademarks are trademarks of their respective owners. Rather than put a trademark symbol after every occurrence of a trademarked name, we use names in an editorial fashion only, and to the benefit of the trademark owner, with no intention of infringement of the trademark. Where such designations appear in this book, they have been printed with initial caps. McGraw-Hill eBooks are available at special quantity discounts to use as premiums and sales promotions, or for use incor- porate training programs. For more information, please contact George Hoare, Special Sales, at george_hoare@mcgraw- hill.com or (212) 904-4069. TERMS OF USE This is a copyrighted work and The McGraw-Hill Companies, Inc. (“McGraw-Hill”) and its licensors reserve all rights in and to the work. Use of this work is subject to these terms. Except as permitted under the Copyright Act of 1976 and the right to store and retrieve one copy of the work, you may not decompile, disassemble, reverse engineer, reproduce, modify, create derivative works based upon, transmit, distribute, disseminate, sell, publish or sublicense the work or any part of it without McGraw-Hill’s prior consent.
    [Show full text]
  • KNOW the LINGO – WHAT IS Category CABLE?
    KNOW THE LINGO – WHAT IS CategoRY CABLE? By: Joseph D. Cornwall, CTS-D Technology Evangelist—Lastar, Inc. Technical lingo is a kind of shorthand that’s used to express concepts common to that specific topic or area of study. Technical lingo is important because it provides a very precise or unique “shorthand” description of a device, effect or concept. Unfortunately, if you aren’t comfortable and familiar with the lingo of a topic it can be a tall hurdle to communicate efficiently with folks who consider the jargon of their field to be “self-explanatory.” In this series of articles we’ll lift the veils of misunderstanding from the lingo of the A/V industry. WHAT IS A CAT CABLE? The concept of Category cables was first set forth by the Electronic Industries Alliance (EIA) and is now maintained by the Telecommunications Industry Association (TIA). In 1991 the TIA/EIA-568-A standard was released (now revised to TIA/EIA-568-C) in an effort to define standards for telecommunications installations. In particular, the standard worked to define elements of balanced twisted pair cabling, fiber optic cabling and coaxial cabling, along with the associated connectors. The Cat cables discussed here are of the unshielded twisted pair (UTP) variety. You can’t be in the A/V or IT industry and not have heard of Cat5e and Cat6 cables. The Cat, as you might know, is short for “Category.” The term “Category” refers to the different levels of performance in signal bandwidth, attenuation and crosstalk associated with each cable’s design.
    [Show full text]
  • United States Patent (19) 11 Patent Number: 5,340,333 Schroth (45) Date of Patent: Aug
    USOO5340333A United States Patent (19) 11 Patent Number: 5,340,333 Schroth (45) Date of Patent: Aug. 23, 1994 (54) SHIELDED MODULARADAPTER 5,130,893 7/1992 Straate et al. ....................... 361/392 75) Inventor: Walter D. Schroth, Chester Springs, OTHER PUBLICATIONS Pa. Cables to Go, Trade Literature for Modular Adapters, 73) Assignee: Interconnect Systems Group Inc., Computer Shopper, p. 330 (Mar., 1992). Exton, Pa. National Computer Accessories, Trade Literature for (21) Appl. No.: 5,895 RJ11 Modular Adapters, Computer Shopper, p. 450 (Mar., 1992). 22 Filed: Jan. 15, 1993 AltexElectronics, Inc., Trade Literature for Modular I51) Int. Cl. ........................................... H01R 13/648 Adapter Kits, Computer Shopper, p. 645 (Mar., 1992). 52 U.S. Cl. ...................................... 439/607; 439/95; Primary Examiner-Gary F. Paumen 439/638 Assistant Examiner-Hien D. Vu 58) Field of Search ..................... 439/95, 96, 97, 108, Attorney, Agent, or Firm-Synnestvedt & Lechner 439/92, 638, 654, 650, 676,607, 609 57 ABSTRACT (56) References Cited Modular adapters and similar devices are provided by U.S. PATENT DOCUMENTS this invention which minimize electrostatic interference 3,699,498 10/1972 Haitmanek et al. ................. 439/248 and arcing. These devices include a pair of electrical 3,850,497 11/1974 Knemreich et al. ................ 439/545 connectors joined together with a series of electrical 3,860,316 1/1975 Hardesky ............................ 439/344 conductors. Each of the connectors is provided with a 4,236,779 12/1980 Tang .............. 439/638 surrounding electromagnetic shield, and these shields 4,387,949 6/1983 Haitmanek. ... 439/95 4,392,701 7/1983 Weidler ...... are bridged together with a separate conductor element.
    [Show full text]
  • What Is a Registered Jack? Getting RJ Connector Names Confused
    RJ-45 RJ-45 is one of the more popular standardconnector types used with unshielded, twisted pair network cables. The RJ-45 connector type is commonly used with Ethernet cables and includes eight pins that interface with the cable wires electrically and is sometimes used with shielding cabling. The pin-outs of the connector are defined to provide cable manufacturers the location that wires need to be placed when attaching the cable to a RJ-45 connector type. There are a number of other connector types on the market such as RJ-11used for telephone cable connections, but are more narrowly shaped. What is a Registered Jack? The RJ designation for the RJ-45 cable stands for “registered jack” and indicates that the connection is defined in the international standard for physical network interfaces. The standard defines both the wiring pattern and connecting jack construction for those intended for use in data services or telecommunications equipment. The interfaces defined in the RJ standard include RJ-11, RJ-14, RJ-21, RJ-45, and the RJ-48 connector types. Of the defined connectors, the RJ standard primarily makes use of the 50 pin miniature ribbon and modular connector types depending on the specific RJ type that is defined. Getting RJ Connector Names Confused Since the RJ standard defines both the physical geometry and the required wiring pattern, an inspection of just the connector type will not necessarily indicate the type of wiring pattern used in the cable. This is due to the fact that the same connector can be used for different wiring patterns! As a result, there has been a fair amount of confusion by consumers on what type of cable standard is being used depending on the application.
    [Show full text]
  • Twisted-Pair Cable • UTP—Unshielded Twisted-Pair • STP—Shielded Twisted-Pair
    The NIC must match the Address/Data Bus of the computer. ISA PCI 55 Installing the NIC in the computer. • NIC installed inside the computer. • Normally plugs into a bus slot. • Some are built right into the motherboard. • Plug-in boards must be configured correctly. 56 NIC Configuration Methods • Plug-and-Play • EEPROM • Jumper pins 57 Preparing to Install the NIC • Ensure there is an open bus slot. • Ensure the adapter is compatible. • Ensure there are system resources available. • Ensure all installation items are available. • Ensure all software is available. 58 Installing the NIC Hardware • Configure the NIC to available resources. • Use a ground strap. • Remove cover from the computer. • Remove rear panel slot cover plate. • Remove card from its antistatic bag and immediately plug it into motherboard. • Secure card slot cover plate to computer.59 Installing the NIC Software • Loading the device driver used by the NIC. • Loading any utilities supplied with the NIC. 60 NIC Device Driver • Supports communication between the NIC and OS. • Automatically installed and configured if both NIC and OS support PnP. • In other cases, driver loaded from floppy or CD supplied with NIC. 61 A more recent device driver may be available at the website of the NIC manufacturer. 62 Troubleshooting the NIC • Is NIC talking to the motherboard? • Is the NIC working internally? • Is the NIC communicating with the external network? 63 LEDs Link Activity 64 Twisted-Pair Cable • UTP—Unshielded Twisted-Pair • STP—Shielded Twisted-Pair 65 Twisted-Pair Cable Foil Foil Shield Wire Shield Braid Shield STP UTP STP 66 10BaseT Ethernet uses Unshielded Twisted Pair (UTP) cable.
    [Show full text]
  • LDT/MDT Range
    348 Victoria Rd Rydalmere, NSW 2116 Phone: (02) 9684 7777 Fax: (02) 9684 7208 www.MitsubishiElectric.com.au All information contained herein is subject to change without prior notice. HDMI, and High-Definiton Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries. is a trademark of the Video Electronics Standards Association, registered in the U.S. and other countries. Other brand, product, and service names are trademarks or registered trademarks of the respective companies. Product appearance in this brochure does not imply that Mitsubishi Electric Corporation intends to make it available in all countries where the company and its subsidiaries operate. LCD DISPLAYS FOR DIGITAL SIGNAGE APPLICATIONS Photographs are simulated images. New publication, effective Jun. 2010 Specifications subject to change without notice. Introducing the Ultimate Experience in Digital Signage Specially engineered for public display applications Unsurpassed functionality and high durability ensure superior performance Digital signage with stunning high-definition image quality aesthetically integrated in public spaces such as airports and commuter stations. into any commercial-use environment. Advanced MDT Series LCDs Economical LDT Series LCDs *Photographs are simulated images. MDT421S/MDT521S/MDT651S Highly functional, durable public displays for Link Up to Five Displays in Series using CAT5 6-axis Colour Adjustment Connections Using the remote controller it is possible to choose a specific colour from R, G, B, C, M or Y and adjust its hue and saturation independently. demanding commercial-use applications Use the daisy-chain connection function of the CAT5 receiver and This is especially useful for adjusting the colours of specific parts in output terminal to link up to five displays in series via CAT5 cables.