8'-11"  “

4 1/2" AREA 1 DEMOLITION 1. REMOVE EXISTING TOILET PARTITIONS, 3'-6" 5'-5" 3'-0" 3'-0" 3'-0" 3'-0"  “ PLUMBING FIXTURES AND VANITY. EXHAUST FAN 2. REMOVE PORTION OF EXISTING WALL TO SUIT PROVIDE FRAMED 2'-0" NEW DOOR LOCATION. WT2 NEW 2x4 WALL BULKHEAD & EXHAUST 3. REMOVE EXISTING FLOOR TILES THROUGH EXTERIOR 4. REMOVE EXISTING BASE BOARD TRIM WALL TYP

EF-1 EF-2 AREA 2 DEMOLITION AREA 1 1 1. REMOVE EXISTING TOILET PARTITIONS, 2'-0" BULKHEAD FOR E2 3 202 PLUMBING FIXTURES AND VANITY. EXHAUST FAN 3'-1" 2. REMOVE PORTION OF EXISTING WALL TO SUIT DUCT TO EXTERIOR NEW DOOR LOCATION. WALL SEE TYPICAL 3. REMOVE EXISTING FLOOR TILES E1 1 WT1 DETAIL 1 4. REMOVE EXISTING BASE BOARD TRIM 6'-4" E1

3 3 3 3

2 2 2'-8" E2 202

5'-6" 2

6 AREA 2

6 2'-7" 1 101 NEW 2'-10"x6'-8" DOOR

1 AREA 3 NEW 2x4 INFILL 4 102 WALL EF-2 INFILL STUD WALL 5 TO SUIT NEW DOOR LOCATION

7 NEW 2'-10"x6'-8" DOOR AREA 3 DEMOLITION 1. REMOVE PORTION OF EXISTING WALL TO SUIT NEW DOOR LOCATION. 6 PLAN 3/8"=1'-0" 3 DEMOLITION 3 E1 203 2 NOTE: E2 GENERAL NOTES CURRENT DESIGN & SPECIFICATIONS 1 1 SHOW MANUAL FLUSH TOILETS WITH 1.0 GENERAL 103 TANKS. CONTRACTOR TO PROVIDE OWNER WITH AN ADDITIONAL "ADD PRICE" 1. THE FOLLOWING NOTES ARE INTENDED TO SUMMARIZE THE 10. INSTALL NEW DOORS AS PER LAYOUT PLAN GENERAL INTENT OF THE OF THE WORK AND MUST NOT BE 11. AS PER FINISH SCHEDULE NEW 3'-0"x6'-8" TO SUPPLY AND INSTALL TANKLESS AUTO CONSTRUED AS LIMITING THE SCOPE OF THE WORK. MAKE 12. INSTALL FLOORING AS PER FINISH SCHEDULE DOOR FLUSH TOILETS. ALLOWANCE FOR WORK THAT IS NORMALLY INCIDENTAL TO THE 13. INSTALL ALL MILLWORK, PLUMBING & ELECTRICAL FIXTURES, TOILET SUPPLY AND INSTALLATION OF THE WORK SHOWN. PARTITIONS & WALL MOUNTED BATHROOM ACCESSORIES. 2. VISIT THE JOB SITE TO REVIEW THE LOCATION OF THE WORK AND 14. INSTALL FINAL TRIM. REVIEW LOGISTICS OF THE REQUIRED CONSTRUCTION. 3. IN THE COURSE OF EXECUTING THE WORK, COMPLY WITH THE MORE 3.0 PLUMBING NOTES STRINGENT OF OCCUPATIONAL HEALTH AND SAFETY REQUIREMENTS WASHROOM ACCESSORIES SCHEDULE OF BRITISH COLUMBIA AND/OR THE VILLAGE OF KEREMEOS SAFETY 1. PLUMBING INSTALLATION SHALL COMPLY WITH THE NATIONAL 1. SOAP DISPENSERS - 3 REQ'D REGULATIONS. THIS INCLUDES THE FURNISHING OF ALL PERSONNEL PLUMBING CODE OF CANADA AND THE BC BUILDING CODE(LATEST 2. SURFACE MOUNT PAPER TOWEL DISPENSOR- 3 REQ'D PROTECTIVE EQUIPMENT, SCAFFOLDING, ETC. EDITIONS). PLAN 1/2"=1'-0" 3. DOUBLE ROLL TOILET TISSUE DISPENSERS - 6 REQ'D 4. OBTAIN WORK PERMITS AS REQUIRED FROM VILLAGE AND DISTRICT. 2. INSTALL CLEAN-OUTS AND PLUMBING VENTS AS PER CODE 4. GRAB BARS FOR W.C - 1 REQ'D 5. SITE CONFIRM ALL DIMENSIONS SHOWN ON DRAWINGS PRIOR TO REQUIREMENTS. UPDATED WASHROOM 5. ANGLED GRAB BARS FOR W.C - 1 REQ'D SHOP DRAWING AND FABRICATION. INFORM ENGINEER OF ANY 3. INSTALL ISOLATION VALVES ON ALL WATER LINE CONNECTIONS TO 6. TRASH BASKET - 3 REQ'D DISCREPANCIES AND/OR ANY DESIRED MODIFICATIONS OR EQUIPMENT AND PLUMBING FIXTURES. LAYOUT 7. BABY CHANGE TABLE - 1 REQ'D SUBSTITUTIONS. 4. CONTRACTOR TO SUPPLY AND INSTALL TANKLESS AUTO-FLUSH 6. CLOSELY COORDINATE WITH ALL OTHER REQUIRED TRADES. TOILETS ONLY 7. MAINTAIN WORK AREA IN CLEAN AND TIDY CONDITION. PROTECT ALL EXISTING BUILDING FEATURES AND EQUIPMENT DURING THE 4.0 EXISTING CONDITIONS COURSE OF THE WORK. 8. PREPARE AND SUBMIT SHOP DRAWINGS FOR REVIEW BY THE 1. CONTRACTOR IS RESPONSIBLE FOR SITE CONDITIONS DURING ENGINEER PRIOR TO FABRICATION. CONSTRUCTION AND ANY DAMAGE OR REPAIR REQUIRED TO THE EXISTING BUILDING/STRUCTURE RESULTING FROM THE 2.0 CONSTRUCTION SEQUENCE CONSTRUCTION.

1. SITE CONFIRM ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. REMOVE ALL EXISTING WASHROOM PLUMBING FIXTURES WITHOUT DAMAGE FOLLOWING DEMOLITION PLAN. 3. COORDINATE WITH THE OWNER THE REQUIREMENTS TO SALVAGE ANY EXISTING MATERIALS, FIXTURES OR

4. BATHROOM STALL DIVIDING WALLS 5. REMOVE EXISTING WALL SHEATHING WHERE REQUIRED FOR NEW PLUMBING/ ELECTRICAL ROUGH IN. 6. CONFIRM ALL WALLS OR SECTIONS OF WALLS TO BE REMOVED OR DEMOLISHED ARE NOT STRUCTURAL LOAD BEARING WALLS. IF WALLS ARE FOUND TO BE STRUCTURAL LOAD BEARING DO NOT DEMOLISH & INFORM ENGINEER IMMEDIATELY. 7. REMOVE EXISTING WALLS SHOWN ON DEMOLITIONS PLAN. 8. INSTALL NEW WALLS AS SHOWN ON LAYOUT PLAN. 9. ROUGH IN FOR ALL NEW PLUMBING FIXTURES & ELECTRICAL FIXTURES.. 10. INSTALL NEW EXHAUST VAN/DUCT BULKHEADS 9. PATCH/INSTALL NEW GYPSUM SHEATHING.

PROJECT No. 082183 0 02/27/14 D.D. S.R. ISSUED FOR TENDER VICTORY HALL SCALE AS SHOWN VILLAGE OF KEREMEOS C 08/21/12 D.D. S.R. ISSUED FOR PRICING DRAWN SR WASHROOM RENOVATION B 08/02/12 D.D. S.R. ISSUED FOR FINAL CLIENT REVIEW VILLAGE OF DESIGNED DD A 06/27/12 D.D. S.R. ISSUED FOR CLIENT REVIEW

NO. DATE ENG. BY SUBJECT DRAWING NUMBER REV. NO. SHEET KEREMEOS KEREMEOS WASHROOM LAYOUT AND DEMOLITION PLANS REVISIONS 1 20122108-1-201 0 6  “ NEW DUCT EXISTING CEILING EXISTING CEILING NEW INFILL WALL BULKHEAD STRUCTURE 6'-4" STRUCTURE

EXISTING EXTERIOR EXISTING EXTERIOR WALL WALL

NEW 2'-10"x6'-8' DOOR NEW 2'-10"x6'-8' DOOR

NEW INTERIOR 3'-0" 3'-0" 3'-0" 3'-0" WALL

3'-8" 3 203 1'-6" 1'-6" EXISTING WALL 1'-6" 1'-6" 1'-6" 1'-6" TYP 7'-0" 3'-4" 2'-10" 2'-10" 1'-5"

PROVIDE OPENING AND 2-8"x12" VENT COVER IN EXISTING FLOOR REMOVABLE SKIRT EXISTING FLOOR STRUCTURE STRUCTURE

1 ELEVATION 1/2"=1'-0" 1 ELEVATION 1/2"=1'-0" 201 VIEW E1 201 VIEW E2

NEW EXHAUST FAN NEW EXHAUST FAN PROVIDE FRAMED PROVIDE FRAMED BULKHEAD & EXHAUST EXISTING CEILING BULKHEAD & EXHAUST EXISTING CEILING 3'-6" THROUGH EXTERIOR STRUCTURE THROUGH EXTERIOR STRUCTURE WALL TYP WALL TYP EXISTING EXTERIOR WALL

EXISTING INTERIOR WALL MIN 6'-8" CLR. TO FLOOR TO FLOOR MIN 6'-8" CLR. 3'-8" EXISTING EXTERIOR 3 WALL 3'-1" 1'-4" 1'-4" 1'-4" 1'-3" 1'-9" 203 NEW INTERIOR WALL 1'-6" 7'-0" 3'-4" 3'-3" 2'-10" 1'-5"

PROVIDE OPENING AND 8"x12" VENT COVER IN REMOVABLE SKIRT EXISTING FLOOR EXISTING FLOOR STRUCTURE STRUCTURE

2 ELEVATION 1/2"=1'-0" 2 ELEVATION 1/2"=1'-0" 201 VIEW E1 201 VIEW E2

PROJECT No. 082183 0 02/27/14 D.D. S.R. ISSUED FOR TENDER VICTORY HALL SCALE AS SHOWN VILLAGE OF KEREMEOS C 08/21/12 D.D. S.R. ISSUED FOR PRICING DRAWN SR WASHROOM RENOVATION B 08/02/12 D.D. S.R. ISSUED FOR FINAL CLIENT REVIEW VILLAGE OF DESIGNED DD A 06/27/12 D.D. S.R. ISSUED FOR CLIENT REVIEW

NO. DATE ENG. BY SUBJECT DRAWING NUMBER REV. NO. SHEET KEREMEOS KEREMEOS WASHROOM ELEVATIONS REVISIONS 2 20122108-1-202 0 6 NEW EXHAUST FAN PROVIDE FRAMED BULKHEAD & EXHAUST EXISTING CEILING EXISTING CEILING PL BACKSPLASH ON PL BACKSPLASH ON THROUGH EXTERIOR STRUCTURE 3'-6" STRUCTURE 3/4" PLY TO MATCH 3/4" PLY TO MATCH WALL TYP COUNTER. ADHERE TO COUNTER. ADHERE TO WALL & COUNTER WALL & COUNTER 1'-11 1/2" 1'-11 1/2"

1" CORIAN COUNTER 1" CORIAN COUNTER TOP TOP 1 1/2" 2x4 LEDGER 1 1/2" 2x4 LEDGER 4" 4" 3" 3" TO FLOOR MIN 6'-8" CLR. 3'-8" GRAB BARS 4 PLY GABLE PLY GABLE - @ 48" O/C MAX @ 48" O/C MAX EXISTING WALL 1'-9" NEW WASHROOM TYP DOOR 11 1/2" 11 1/2" 7'-0" ROUTE ALL SUPPLY 1'-6" EXIST EXTERIOR & DRAIN LINES WITHIN 2'-10" 2'-10" WALL 10" THE CABINET SPACE 10" NOTE:

3'-4" HOT WATER SERVICE NEW INTERIOR 2'-10" 2'-10" LINE TO BE FULLY INSULATED

2'-5" WALL 2'-7 1/2" UNDER COUNTER ROUTE ALL SUPPLY 1'-5" & DRAIN LINES WITHIN THE CABINET SPACE. VENT LINES TO ROOF TO BE LOCATED IN THE NEAREST INTERIOR WALL REMOVABLE SKIRT SECTION EXISTING FLOOR EXISTING FLOOR STRUCTURE STRUCTURE EXISTING FLOOR STRUCTURE 3 ELEVATION 1/2"=1'-0" 3 ELEVATION 1/2"=1'-0" 201 VIEW E1 201 VIEW E2 3 3 DETAIL 4 DETAIL - 202 TYPICAL VANITY AT 202 TYPICAL VANITY AT EXTERIOR WALL INTERIOR WALL

EXISTING CEILING STRUCTURE ROOM FINISH SCHEDULE ADJUSTABLE ROOM FLOOR WALLS CEILING DOORS FRAMES DOOR FRAME NAME NORTH EAST SOUTH WEST ADJUSTABLE DOOR FRAME NEW STUD WALL: MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH 2x4 STUDS @ 16" 0/C SOLID CORE PAINT SOLID CORE PAINT 1/2" GYPSUM SHEATHING GRADE DOOR PANEL GRADE DOOR PANEL 2 COATS 2 COATS 2 COATS 2 COATS 2 COATS EACH SIDE. PAINT 101 MENS RESILIENT TILE PRE-FINISHED GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT PAINT INTERIOR WALL JAMB INTERIOR WALL HEAD 2 COATS 2 COATS 2 COATS 2 COATS 2 COATS NOTE: 102 WOMENS RESILIENT TILE PRE-FINISHED GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT PAINT PAINT CONTRACTOR TO MATCH

VARIES EXISTING WALL STUD 103 WHEEL CHAIR 2 COATS 2 COATS 2 COATS 2 COATS 2 COATS

GYPSUM/PAINT GYPSUM/PAINT PAINT PAINT SITE CONFIRM SIZES WHERE NEW ACCESIBLE RESILIENT TILE PRE-FINISHED GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT GYPSUM/PAINT LATEX PAINT LATEX PAINT LATEX PAINT 4 DETAIL 1"=1'-0" INFILL WALL AREAS ARE - TYPICAL PRESSED TO BE CONSTRUCTED STEEL DOOR FRAME NEW BASE BOARD DOOR SCHEDULE TO OWNER SPEC

OPENING LOCATION FRAME DOOR HARDWARE REMARKS

ROUGH OPENING EXISTING FLOOR STRUCTURE SWEEP DEAD BOLT FLUSH BOLTS ASTRAGAL PANIC BAR FIRE RATING (HOURS) DOOR FROM ROOM TO ROOM WIDTH HEIGHT SWING LOCKSET PASSAGE SET PRIVACY SET D-PULL CLOSER STOPPER THRESHOLD WEATHERSTRIP

1 SOLID CORE DOOR, PAINT GRADE EXISTING HALLWAY 101 MENS 3'-0" 6'-9 1/2" LHOS 101 UNDERCUT 2" FROM FLOOR 4 SECTION 1"=1'-0" 1 SOLID CORE WOOD DOOR, PAINT GRADE EXISTING HALLWAY 102 WOMENS 3'-0" 6'-9 1/2" LHIS - 102 UNDERCUT 2" FROM FLOOR TYPICAL NEW

1 SOLID CORE WOOD DOOR, PAINT GRADE STUD WALL EXISTING HALLWAY 103 WHEELCHAIR ACCESIBLE 3'-2" 6'-9 1/2" RHOS 103 UNDERCUT 2" FROM FLOOR

PROJECT No. 082183 0 02/27/14 D.D. S.R. ISSUED FOR TENDER VICTORY HALL SCALE AS SHOWN VILLAGE OF KEREMEOS C 08/21/12 D.D. S.R. ISSUED FOR PRICING DRAWN SR WASHROOM RENOVATION B 08/02/12 D.D. S.R. ISSUED FOR FINAL CLIENT REVIEW VILLAGE OF DESIGNED DD A 06/27/12 D.D. S.R. ISSUED FOR CLIENT REVIEW

NO. DATE ENG. BY SUBJECT DRAWING NUMBER REV. NO. SHEET KEREMEOS KEREMEOS WASHROOM ELEVATIONS SECTIONS & DETAILS REVISIONS 3 SCHEDULES 20122108-1-203 0 6 1. GENERAL NOTES: 2. SHOP DRAWINGS - Post Forming 0.75 mm .3 Adhesives: as recommended by flooring manufacturer and adhesive Backing - GP-BK-R 1.15 mm or 0.75 mm WOOD DOORS manufacturer for each flooring material and type and location of substrate. 1. EXAMINATION AND COORDINATION .4 Sealer and Wax: as recommended by flooring manufacturer for flooring type Thickness same as face sheet, without decorative treatment. and location. .1 Contractor to examine all drawings, notes, specifications and existing site .1 Submit shop drawings. Clearly indicate details of construction, profiles, 1. MATERIALS conditions to assess all work to be performed by all contractors/trades , fastening and other related details. .5 Adhesive: To CSA 0 112.7-M1977 .2 Coordinate and cooperate with all related trades as to built-in requirements .6 Exposed Surface Finishes .1 Doors: To CSA 0 132.2M, Series 90, AWMAC Institutional Grade. 8. CONDITION OF SUBSTRATES and sequence of work. 3. MATERIALS .1 Vertical Surfaces - Suede finish. .2 Solid Wood Core (SCW): shall be A1 premium grade Structural Composite .2 Horizontal Surfaces - Matte finish. core with 5 ply hot pressed door construction. Face veneer to .1 (QVXUHIORRUVXUIDFHVDUHVPRRWKDQGIODWWR“PPRYHUP 2. DELIVERY AND STORAGE .1 Lumber: To CSA 0141-70, kiln dried, 6% maximum humidity .7 Accepted Manufacture: Arborite, Nevamar, Formica, Deco. cross-banded to solid wood core. Shop pre-fitted. content for interior work. Refer to drawings for details. .8 Colours and Patterns: Consultant reserves the right to select colours and .3 Core (PBC): To CSA 0 188.1M, 448 kg/m density, fully .1 Protect materials from weather while in transit and on job site. .2 Lumber: AWMAC Premium Grade, 6% maximum humidity patterns from listed accepted manufacturers. bonded core. .2 Store all new materials on site to prevent damage, deterioration, loss or 9. SUBSTRATE PREPARATION content. Refer to drawings for details. Refer to door schedule for Building and Modules. impairment of structural or other essential properties. Avoid rapid changes in .9 Composite Laminate Panels: To NEMA Standard LQ1, Formica melamine .3 Face Veneers: To AWMAC Institutional Grade, stain grade as per door .1 Remove sub floor ridges and bumps. Fill low spots, cracks, joints, holes and moisture content. .3 Softwood : To CSA - 121-M78. composite panel (MCP), or approved substitute, consisting of melamine resin impregnated paper thermal-fused to mat-formed wood particle board schedule. other defects with sub floor filler. .3 Make no delivery until site conditions are adequate to receive the work of .4 Hardwood Plywood: To CSA 0115-M82. core. .4 Edging: AWMAC No. 1 edge solid hardwood to match face veneer, paint .2 ,IH[LVWLQJFRQGLWLRQVUHTXLUHFRQWUDFWRUWRSURYLGHPLQó´SO\XQGHUOD\PHQW this section. Protect materials from weather while in transit to site. .5 Particle Board: To CAN3-0188.-M78, interior, mat-formed, Grade R, to .10 All wood blocking, trim, , bracing, where shown shall be No.1 clear grade. glued & screwed to existing su-floor. .4 Adequately protect finish surfaces during delivery, handling and storage. thickness indicated. grade B.C. , free from all manufacturing or natural defects, kiln-dried to a .5 Adhesive: To CSA 0 132.2M, Type I and II. No.1 adhesive, No.1 water .3 Ensure prepared surface is clean and free off all loose debris. .5 Use proper handling equipment to prevent damage. .6 Plastic Laminate: To CAN3-A172-M79, general purpose grade, solid colour or , suede finish unless noted otherwise. Backing sheet of same moisture content of 8%. All hardwood shall be select, clear, without knots, resistant, hot pressed construction. Refer to Door Schedule. thickness on all plastic laminated plywood assemblies. Consultant will select free from sap or pitch marks, and contain no bark edge, or heart wood, all 10. INSTALLATION, GENERALLY 3. PROTECTION from varying manufacturers to establish the final selection at a later date. kiln-dried to a moisture content of 8%. Submit hardwood samples for 2. FABRICATION approval before ordering any materials. .7 Adhesive: To CSA 0112-M77, waterproof. For plastic laminate .1 Provide interim protection for completed work until Substantial Performance manufacturer's recommendations .1 Manufacture all doors to produce fully balanced door units so as not to .1 Apply adhesive as recommended by manufacturer. Ensure adhesion over has been achieved. 6. FABRICATION .8 Hardware: induce warpage or veneer defects. For sizes and types refer to Door entire area of installation. .2 Provide all necessary protection to adjacent work against any damage .1 Nails and Staples: To CSA B111-74, galvanized. Schedule. No core telegraphing will be accepted. .2 Set flooring in place, press with minimum 45 kg roller to ensure full adhesion. resulting from this work. .1 Fabricate to AWMAC premium grade construction. .2 Fabricate cores of fully bonded wood or particleboard complete with 100mm .3 Take responsibility for replacement and repair of any damage or breakage at .3 Terminate resilient flooring at centerline of door in door openings where 4. WOODWORK .2 All cabinets, built-ins and counters to be constructed of medium density fiber laminated rails and 127mm wide laminated stiles. no extra cost to the client board, except for shelving which shall be plywood, to thickness indicated on .3 Provide continuous 15mm thick solid wood edging, beveled to suit function. adjacent floor finish is dissimilar. drawings. Plywood to receive plastic laminate shall be to sanded Grade B .1 Only on-site fabricated and erected woodwork is covered hereunder. .4 Prepare cores to receive pressure applied hardwood cross banding and 4. COMPLETION AND CLEAN UP veneer G1S popular plywood or particle board. scheduled face veneers. 11. INSTALLATION OF SHEET FLOORING .3 Counter tops shall be plastic laminate and/or post-formed plastic laminate .5 Manufacture scheduled or detailed side panels and transom panels of same 5. WOOD BASES .1 Clean up and remove all rubbish and surplus materials from the site as the finished as detailed on drawings. manufacture as doors. Rated doors required rebated astragal panel edges. work proceeds and at completion leaving the site in a clean and tidy .4 Provide complete composite laminate panel finish in interior of all cabinets .1 Lay sheet flooring with seams parallel to building lines to produce a minimum .1 Where scheduled, indicated detailed and profiled wood bases shall be solid condition to Consultant and/or owners approval. and drawers. No exposed wood acceptable. This shall include all interior 3. INSTALLATION number of seams. Where applicable, locate seams at centerline of door in grade Birch. No finger joints shall be allowed. gables, underside of shelves and backs. door openings. .2 All internal or external intersections shall be straight tightly butted mitred .5 Shop apply plastic laminate finishes to units as detailed. Adhere plastic ROUGH .1 Install wood doors and hardware into prepared wood framed openings in .2 ,QVWDOOVKHHWIORRULQJZLWKPLQLPXPVKHHWZLGWKѿIXOOPDWHULDOZLGWKDQGZLWK joints, all butted joints shall be tight and straight. Only hairline joints shall be laminate over entire surface. Make corners with hairline joints. Use full-sized strict accordance with manufacturer's templates and instructions. sheet parallel to walls. acceptable. laminate sheets. Make joints only where approved. 1. QUALITY ASSURANCE .2 Adjust and correct all operating parts to assure a smooth and trouble_free .3 Provide seams in strict accordance with manufacturer's recommendations. .6 Fit shelves, doors, drawers and gables with plastic laminate edging of continuous operation. Heat weld seams with welding rod. 6. FINISH thickness 1.59mm. Plastic PVC edging not acceptable. .1 All lumber shall be clearly grade stamped in accordance with the National .4 Prepare and sand all wood surfaces smooth and even, ready to receive .7 Check and verify dimensions of all sinks to be installed in the counter tops .4 Scribe sheet vinyl flooring to produce tight joints. Lumber Grades Authority Standard Grading Rules prior to delivery. specified finishes. .1 Prepare and sand all wood surfaces smooth and even, ready to receive before fabrication. Any discrepancies must be brought immediately to the specified finishes. attention of the Consultant. 2. LUMBER MATERIAL 12. INSTALLATION OF ACCESSORY COMPONENTS .8 Check, verify and obtain actual on-site dimensions for built-in or contained RESILIENT FLOORING ARCHITECTURAL WOODWORK woodwork components. .1 All wood in accordance with CSA 0141, graded to Standard Grading Rules .9 Shop fabricate all architectural woodwork, assembled in practical size and .1 Install metal edge strips at unprotected and exposed edges where flooring for Canadian lumber, dressed S4S, best quality kiln-dried wood, free from delivered ready for installation. 1. SUBMITTALS terminates. deficiencies affecting its strength and finished appearance. 1. QUALITY ASSURANCE .10 Provide sufficient allowance to components for on-site cutting and fitting. .1 Submit duplicate tile in size specified, 300 mm sample pieces of 13. CLEANING .2 Sizes as indicated on drawings or as otherwise functionally required. Provide tacked-on wood scribe trim for on-site wall fittings. Maximum .1 0LOOZRUNVKDOOFRQIRUPWRWKH³4XDOLW\6WDQGDUGIRU$UFKLWHFWXUDO:RRGZRUN sheet material, 300 mm base, required for this project, for owners approval. .3 Blocking, Furring, Grounds, Nailing strips not exposed to View: 20 mm wide. .1 Remove excess adhesive from floor, base and wall surfaces without of the Eight Edition of the Architectural Woodwork Manufacturers construction grade. .11 Secure component sections rigidly together with suitable bolting methods. .2 Submit manufacturer's printed recommendations for installation of products. damage. Association of Canada. Where applicable, include detailed recommendations for seaming sheet .4 Non- Grade Lumber for Framing, Blocking and Back-Up: SFP No. 1. .12 Conceal all fastenings. Should exposed fastening be required and approved .2 Clean, seal and wax floor and base surfaces to manufacturer's written .2 Construct millwork, unless detailed otherwise, to premium grade. vinyl. by the Consultant, use nickel-chromed screws complete with grommet instructions. 3. PLYWOOD washers. Use wood plugs for bolt head concealment, wood plugs to match .3 Provide manufacturer's printed recommendations for general maintenance, 2. SHOP DRAWINGS wood grain and specie. including cleaning instructions and guidelines for use of waxes and other protective coatings and appearance enhancers. 14. PROTECTION OF COMPLETED WORK .1 Plywood: To CSA 0121, exterior sheathing grade, to thickness indicted on .13 Make all preparation and adjustments necessary to woodwork components the drawings. .1 Submit shop drawings in accordance with Section 01300. Clearly indicate to suit utility lines, plumbing fixtures, electrical conduits and fixtures as well details of construction, profiles, jointing, fastening and other related details. as built-in equipment. Coordinate with all related work sections. 2. TESTING AND INSPECTION BY CONTRACTOR .1 Protect new floors from time of final set of adhesive until just before final .2 Submit hardware brochure or graphically descriptive documentation. 4. BUILDER'S HARDWARE inspection. .3 Digital transmissions (Email) will not be accepted and shall be returned. 7. INSTALLATION .2 Prohibit traffic from floor finish for 48 hours after installation. .1 Nails, Spikes, Staples: To CSA B111 galvanized. .1 Ensure existing floor surface is true flat and free of voids/blemishes that will 3. SAMPLES translate through flooring once installed. .2 Bolts, Nuts, Washers Lags, Pins, Screws: Hot dipped galvanized to ASTM .1 Install, set, assemble and secure architectural woodwork in place, plumb, METAL TOILET PARTITIONS A525. level, square and true-to-line. .1 Confirm samples & finishes with owner. .2 Provide properly sized and of suitable capacity bolts to suit both the weight .3 Steel plates, connector, hangers, straps, etc., necessary for connecting and 3. DELIVERY, HANDLING AND STORAGE supporting all componen of woodwork or its final function and the backup wall condition. 8. QUALITY ASSURANCE 4. EXAMINATION .3 Conceal all fastenings. Should it be impossible, use nickel-chromed screw heads and grommet washers to Consultant's approval. .1 Deliver packaged materials in original unopened containers. 5. SHEETING .1 The work of this section shall be executed to current British Columbia .4 Scribe off closure pieces at wall joints and fit to match existing wall condition. .1 Examine all surfaces and actual physical conditions to receive architectural .2 Keep delivered material dry and free from stains. Building Code _ Barrier Free Access and to the highest industry standard .5 Prime coat all surfaces in contact with cementitious materials and at raw .1 Vapour Barrier: Sheet-Polyethylene to CAN2-51.34 M86, Type 1, 6 mill (0.15 woodwork prior to commencement of work. and workmanship in strict accordance with manufacturers' written edge cuts. .3 Store flooring materials in area of flooring installation for 3 days prior to mm) thick. .2 Notify the Consultant in writing, through the Contractor, of any surface installation. Store roll goods vertically. Protect edges from damage. recommendations. defects or conditions that would adversely affect the proper installation of .6 Apply of silicone sealant to joints of backsplash and adjacent wall .2 The work of this section shall be performed by firms having qualified architectural woodwork. finish. 6. BLOCKING AND BACKING experienced personnel with adequate plant to carry out all requirements of 4. ENVIRONMENTAL CONDITIONS .3 Starting work will be interpreted as acceptance of completed work by others. this section. .4 Coordinate this work with all related work sections. 8. QUALITY ASSURANCE .1 Provide wood blocking for support of washroom accessories and any other specified equipment to be supported needing rigid support. Secure wood .1 0DLQWDLQPLQLPXPƒ&DLUWHPSHUDWXUHDQGGHVLJQUHODWLYHKXPLGLW\DW 9. EXAMINATION 5. MATERIALS .1 The work of this section shall be in strict accordance with all requirements of blocking with rigid bolt connections or other methods acceptable to flooring installation area for 3 days prior to, during, and for 24 hours after NFPA 80_1975, Underwriters Laboratories of Canada (ULC), Consultant. installation. CAN4_S101_M 82, CAN/CSA_0132.2 Series 90 and Architectural .2 Provide backboards for mounting specified equipment, mechanical and .1 Use clean stock only and comply with AWMAC Quality Standard for the .1 Examine all surfaces and conditions to receive special items prior to Woodwork Manufacturers Association of Canada (AWMAC). electrical control and distribution panels. Backboards shall be 19mm fir following grades. commencement of work. .2 The work of this section shall be executed by firms having qualified plywood secured to rigid blocking or furring. .2 Casework shall conform to Part 2 of AWMAC Quality Standards Manual as 5. MAINTENANCE MATERIALS .2 Notify the Consultant, in writing through the Consultant, of any defects or applicable. experienced personnel and adequate plant to carry out all requirements of imperfections that would adversely affect the installation and intended this section. 7. STRAPPING, FURRING AND NAILERS .3 Softwood Lumber: To CSA O141-1970 and National Lumber Grades function of the metal toilet partitions. Authority requirements, with maximum moisture content of 6% for interior .1 Deliver 3% overage of factory width sheet flooring of each colour and pattern .3 Starting work will be interpreted as acceptance of completed work by others. 9. SHOP DRAWINGS specified for future maintenance. .1 Provide wood strapping where indicated or as required. Securely or work, yard lumber select edge grain for paint finish, species, to .4 Carefully examine the drawings and specifications and coordinate this work otherwise attach to backing or blocking provided. Coordinate with all other AWMAC custom grade. .2 Clearly identify each box/roll. with all related sections of work listed in 1.1. trades. .4 Hardwood Lumber: Grade to Canadian Standard Lumber "Hardwood" .1 Submit shop drawings for review by consultant. .2 Provide wood furring required to accept work from other trades or to provide requirements, moisture content of maximum 6% for interior work shall be to .2 Submit schedule with door references indicated on the drawings. 6. FLOORING TYPES 10. SHOP DRAWINGS enclosures indicated. AWMAC premium grade. Where indicated on drawings hardwood and shall be varnish grade Birch. 10. EXAMINATION .1 Sheet Linoleum to: ASTM F2034 and as follows: .5 Softwood Plywood: 8. INSULATION .1 Construction: Homogeneous Acoustic Linoleum. .1 Submit shop drawings for review .1 Fir plywood: To CSA O121-M1978 sanded grades G1S/G2S as .1 Examine all prepared framed openings to receive wood doors prior to .2 Provide shop drawings and related product brochures or appropriate required. .2 Manufacturer: Forbo Linoleum Inc. .1 Replace any batt insulation removed/destroyed during construction. commencement of work. graphically descriptive documentation. .3 Product: Marmoleum Fresco. Replaced insulation to match existing.Pack insulation in any other void that .2 Popular plywood to CSA 0153.M80 sanded grade G1S. .2 Notify the Consultant, in writing through the Contractor, of any frame defects .6 Mat-formed Wood particle Board: To CSA 0188 Grade R, sanded faces, that would adversely affect an acceptable and proper wood door installation. .4 Backing: jute. would otherwise create a cold strike or frost penetration. 11. MAINTENANCE DATA 19mm thick. .3 Starting work will be interpreted as acceptance of completed work by others. .5 Width: 2 meters. FINISH CAREPENTRY .7 Nails and Staples: To CSA B111, plain finish galvanized. .4 Carefully examine the drawings and specifications and coordinate this work .6 Thickness: 2.5 mm. .8 Plastic Laminates with all related sections of work listed in 1.1 for work to be performed and for .1 Submit maintenance data and manual for specified metal toilet partitions .7 Pattern and Colour: Barbados 3858. complete with related necessary maintenance to the owner. 1. QUALITY ASSURANCE .1 Accepted manufacturer's listed hereunder shall allow for specified wood doors and hardware to be supplied. product line equivalence. .2 Consultant reserves the right to select final colours and patterns from 7. ACCESSORY MATERIALS .1 Site constructed woodwork shall conform to the "Quality Standard for 11. WARRANTY SEE DWG 205 FOR CONTINUATION OF NOTES. various listed manufacturers. Architectural Woodwork" of the Eight Edition of the Architectural Woodwork .3 Plastic Laminate Standard: To CAN3-A 172-M79. .1 Submit an extended written warranty in accordance with Section 01300. Manufacturers Association of Canada unless specified otherwise, and the .1 Sub Floor Filler: white premix latex requiring water only to produce .4 Grades Thickness National Lumber Grades Authority Standard Grading Rules. .2 Wood doors shall be warranted against deformation beyond 6 mm tolerance, cementitious paste. .2 Construct on-site woodwork, unless detailed otherwise, to quality grade General Purpose - GP(R) 1.15 mm telegraphing, de-lamination, splitting or cracking for a period of three (3) specified. Post forming - PF-30 0.75 mm years from the date of the Consultant's Substantial Performance Review .2 Primers: as recommended by primer and adhesive manufacturer. Acid Resistant- General Purpose 1.15 mm Report and that any defective material will be replaced to its originally intended function.

PROJECT No. 082183 VICTORY HALL SCALE AS SHOWN VILLAGE OF KEREMEOS 0 02/27/14 D.D. S.R. ISSUED FOR TENDER DRAWN SR WASHROOM RENOVATION B 08/21/12 D.D. S.R. ISSUED FOR PRICING VILLAGE OF DESIGNED DD A 08/02/12 D.D. S.R. ISSUED FOR FINAL CLIENT REVIEW

NO. DATE ENG. BY SUBJECT DRAWING NUMBER REV. NO. SHEET KEREMEOS KEREMEOS GENERAL NOTES & SPECIFICATIONS SHEET 1 REVISIONS 4 20122108-1-204 0 6 .1 Bored and preassembled locks and latches: to CAN/CGSB_69.17, 6. PREPARATION .1 Infrared motion sensor activated by hand motion in lavatory. .2 All securements shall be concealed. GENERAL NOTES (cont.) series 4000 bored lock, grade 1, designed for function and keyed. .2 Sensor: waterproof, incorporated in body of unit, with impact_resistant .3 Provide flexible ducting - Thermaflex S-TL, non-insulated HVAC duct (or Approved model: Schlage D-Series. .1 Coordinate all blocking requirements with related work sections. plastic lens and anti_scratch coating, sensitivity adjustable from 100 approved equal) for ducting fan exhaust to exterior. 12. TOILET PARTITIONS .2 Lever handles: typical for all doors to accessible standards. mm to 450 mm. .2 Examine all prepared conditions prior to start of installation and assure .4 Provide aluminum exhaust vents for all new exhaust fans c/w back draft .3 Roses: round. prepared blocking is rigidly in place. .3 Water conservation: 0_60 second maximum run time. prevention, new vents to be weather proof and have bird/rodent screens. .1 Design: Floor mounted, head_rail braced, for standard compartments and .4 Normal strikes: box type, lip projection not beyond jamb. .4 Controls: vandal_proof, interchangeable receptacles for stainless steel paraplegic clearance requirements and wall-mounted privacy screens as sheathed sensor and modular plug_type solenoid connections, single .5 Cylinders: key into keying system as directed. 7. INSTALLATION 5. ACTION AND INFORMATIONAL SUBMITTALS indicated on drawings. 24 VAC slow_closing commercial solenoid for 125psi, 185 degrees F. .6 Finished to 619, Satin Nickel. .2 Door Construction: Panels and pilasters shall be constructed of two sheets .5 Transformer: 120/24 VAC Class 2, UL and CSA listed, hard wire box .1 Product Data: of panel flatness wiped_coated steel, A446 Grade A, laminated under .7 Butts and hinges: .1 Install all washroom accessories specified and indicated on the drawings in type, sized for up to 8 solenoids. .1 Provide manufacturer's printed product literature and datasheets for pressure to a honeycomb core for sound deadening and rigidity. Formed .1 Butts and hinges: to CAN/CGSB_69.18. Acceptable manufacturers: accordance with manufacturer's written recommendations and current British washroom fans, and include product characteristics, performance edges to be welded together and interlocked under tension with a .6 Spout Gooseneck: Chrome plated, with integral flow control aerator Hager, Stanley or Monthard. Columbia Building Code- Barrier Free Design requirements. criteria, physical size, finish and limitations. roll_formed oval crown locking bar, mitred, welded and ground smooth at the rated at 2.2 gpm at 60 psi. .2 All securements shall be concealed. corners. Honeycomb to have a maximum 25mm cell size with compressive .2 Strap and tee hinges and hasps: to CAN/CGSB_69.36, finished to 602 .7 Under_counter temperatures mixing controls, Controls in body of unit .2 Indicate fixtures and trim: (cadmium plated). .3 Seal all joints between accessories and wall finish with silicone sealant. strength of 896 kPa. .2 Acceptable manufacturers: Delta, Sloan, Kohler .1 Dimensions, construction details, roughing_in dimensions Color match to accessory or wall if possible. .3 Doors: 25mm thick with cover sheets not less than 0.7mm thick sandwiched .8 Architectural door trim to CAN/CGSB-69.22, listed in Hardware Schedule: .13 piping: .2 Factory_set capacity. as above. .1 Door protection plates: kick plate, 1.27 mm thick, size 300 high, 100 .1 Hot and cold water supplies to fixtures: .3 Shop Drawings: .4 Panels/Privacy screens: 25mm thick with cover sheets not less than 0.6mm less than door width, stainless steel, finished to #4 brushed. 8. REFERENCES thick for panels up to and including 1162 mm and 0.8mm thick for larger .1 Chrome plated flexible supply pipes with handwheel stop, .1 Provide drawings. .2 Push plates: 1.27 mm thick, size 89 x 381 mm, stainless steel, .1 Canadian Standards Association (CSA International) panels. reducers, escutcheon. finished to #4 brushed. .1 CAN/CSA_B45 Series Plumbing Fixtures. .5 Pilasters: 32mm thick, with cover sheets not less than 0.8mm thick. .2 Waste: 4. CLOSEOUT SUBMITTALS .3 Push/Pull units: size as above push plate, tubular pull handle on .2 CAN/CSA_B125.3 Plumbing Fittings. .6 Headrail: 25mm by 41mm, with a thickness of 0.9mm, securely attached to opposite side to suit, stainless steel, finished to #4 brushed. .1 Brass P trap with clean out on fixtures not having integral trap. wall and a pilaster with manufacturer's fitting to assure a rigid installation. All .3 CAN/CSA_B651 Accessible Design for the Built Environment. 6. FASTENINGS .2 Chrome plated in exposed places. joints in headrails shall be made at pilasters. .1 Provide operation and maintenance data for washroom fans, for incorporation into manual. .7 Pilaster Fastening Method: Pilasters shall be securely and rigidly fastened to .1 Supply screws, bolts, expansion shields and other fastening devices 9. ACTION AND INFORMATIONAL SUBMITTALS 12. APPLICATION the floor and fitted with jack levelling_screw for vertical adjustment. The required for satisfactory installation and operation of hardware. .2 Include: .1 Product Data: floor fastening shall be concealed and protected by 75mm high, die_formed .2 Exposed fastening devices to match finish of hardware. .1 Manufacturer's Instructions: comply with manufacturer's written .1 Description of fixtures and trim, giving manufacturer's name, type, steel pilaster shoe. .1 Provide manufacturer's printed product literature and datasheets for recommendations, including product technical bulletins, handling, storage model, year, capacity. .3 Where pull is scheduled on one side of door and push plate on other side, washroom fixtures, and include product characteristics, performance and installation instructions, and datasheets. .8 Hardware and Fittings: Compartment panels and pilaster shall be secured .2 Details of operation, servicing, maintenance. supply fastening devices, and install so pull can be secured through door criteria, physical size, finish and limitations. with brackets made of brushed finish extruded aluminum alloy. Doors shall from reverse side. Install push plate to cover fasteners. 13. INSTALLATION .3 List of recommended spare parts. be equipped with gravity type hinges, fully concealed within the thickness of .2 Indicate fixtures and trim: .1 Mounting heights: the door and adjustable to permit door to be fitted with chrome plated .4 Use fasteners compatible with material through which they pass. .1 Dimensions, construction details, roughing_in dimensions combined coat hook and bumper, and a concealed latch, with face mortised .1 Standard: to manufacturer's recommendations measured from finished .2 Factory_set water consumption per flush at recommended pressure. flush with edge strip and all working parts fully concealed within the 7. SCHEDULE floor. thickness of the door, with exposed escutcheon plate and handle chrome .3 (For water closets, urinals): minimum pressure required for flushing. .2 Wall_hung fixtures: as indicated, measured from finished floor. plated. The combined stop and keeper shall be zinc die casting, chrome .1 Hinges A5111, NRP, 114 x 101 mm 630. Approved manufacturer: Hager or .3 Shop Drawings: .3 Barrier free: to most stringent Alberta Building Code and CAN/CSA plated with 19mm diameter rubber bumper locked in place. Stanley. B651. .9 Finish: All sheet metal to be thoroughly cleaned, phosphated and spray .2 Deadlock E0151, MK and KA 630. Schlage-D. .1 Provide drawings. 14. ADJUSTING painted with high quality enamel, baked on to provide a uniform, smooth .3 Flush bolts L04081626. protective finish. Colour shall be as selected by Consultant from .1 Conform to water conservation requirements specified this section. .4 Pulls J405, to suit. 10. CLOSEOUT SUBMITTALS manufacturer's standard colour chart. .5 Push plates J301, to suit. .2 Adjustments: .10 Manufacture: Shall be Overhead Braced type as manufactured by .1 Adjust water flow rate to design flow rates. Shanahan's or approved substitution. .6 Closers CO2021. .1 Provide operation and maintenance data for washroom fixtures, for .7 Kick plates 302 x 630 inside. Approved manufacturer: Hager. incorporation into manual. .2 Adjust pressure to fixtures to ensure no splashing at maximum pressures. .2 Include: 13. FABRICATION .3 Adjust flush valves to suit actual site conditions. WASHROOM ACCESSORIES .1 Description of fixtures and trim, giving manufacturer's name, type, model, year, capacity. .4 Adjust urinal flush timing mechanisms. .1 Fabricate metal toilet partitions in accordance with the requirements of the .2 Details of operation, servicing, maintenance. .5 Set controls of automatic flush valves for WCs and urinals to prevent drawing layouts and to the requirements for handicap access and use. 1. QUALITY ASSURANCE unnecessary flush cycles. .3 List of recommended spare parts. .2 Reinforce all panels to receive specified hardware and washroom .3 Checks: accessories. .1 The work specified in this Section shall be in accordance with the current British Columbia Building Code - Barrier Free Design requirements. 11. MANUFACTURED UNITS .1 Water closets, urinals: flushing action. 14. INSTALLATIONS .2 The work of this section shall be executed to the highest industry standard .2 Aerators: operation, cleanliness. and workmanship in strict accordance with manufacturer's written .1 Fixtures: manufacture in accordance with CAN/CSA_B45 series. .3 Vacuum breakers, backflow preventers: operation under all conditions. recommendations. .4 Thermostatic controls: .1 Install metal toilet partitions in accordance with manufacturer's .2 Trim, fittings: manufacture in accordance with CAN/CSA_B125.3. recommendations. .3 The work of this section shall be performed by firms having qualified .1 Verify temperature settings, operation of control, limit and safety experienced personnel with adequate plant and equipment to carry out all .3 Exposed plumbing brass to be chrome plated. .2 Install and rigidly secure wall brackets and floor securements using controls. requirements of this section. .4 Number, locations: as indicated. appropriate system and method to suit wall and floor construction. 15. CLEANING .5 Fixtures in any one location to be product of one manufacturer and of same .3 Secure all panels and head brace. .1 Remove surplus materials, excess materials, rubbish, tools and 2. EXAMINATION type .4 Install all hardware. Adjust as required to assure a trouble_free operation. equipment. .6 Trim in any one location to be product of one manufacturer and of same .5 Touch up finishes as may be required. type. .1 Examine all surfaces and conditions to receive washroom accessories prior WASHROOM EXHAUST FANS to commencement of work. .7 Water closets: DOOR HARDWARE .2 Notify the Consultant, in writing through the Consultant, of any defects or .1 Bowl: vitreous china, syphon jet, elongated rim, close_coupled 1. QUALITY ASSURANCE imperfections that would adversely affect the installation and intended combination, bowl and bolt caps auto flush. function of the items. .2 Floor_mounted, for handicapped. 1. REFERENCES .3 Starting work will be interpreted as acceptance of completed work by others .1 Same as above with top of seat to be between 400 mm and 460 .1 The work specified in this Section shall be in accordance with the current British Columbia Building Code .1 Canadian General Standards Board (CGSB) .4 Carefully examine the drawings and specifications and coordinate this work mm from finished floor .2 The work of this section shall be executed to the highest industry standard .1 CAN/CGSB_69.17, Bored and Preassembled Locks and Latches. with all related sections of work listed in 1.1 for work to be performed. .3 Acceptable manufacturers: Kohler, American standard, Crane, Toto, and workmanship in strict accordance with manufacturer's written .2 CAN/CGSB_69.18/ANSI/BHMA A156.1, Butts and Hinges. .8 Water Closet Seats recommendations. .3 CAN/CGSB_69.20/ANSI/BHMA A156.4, Door Controls (Closers). 3. SHOP DRAWINGS .1 Seat: white, elongated, open front, moulded solid plastic, less cover, stainless steel check hinges, stainless steel insert post. .4 CAN/CGSB_69.21/ANSI/BHMA A156.5, Auxiliary Locks and Associated 2. EXAMINATION Products. .1 Provide shop drawings and related product brochures or appropriate .2 Acceptable manufacturers: Kohler, American standard, Crane, Toto, .5 CAN/CGSB_69.22/ANSI/BHMA A156.6, Architectural Door Trim. graphically descriptive documentation. .9 Urinals: .1 Examine all existing conditions prior to commencement of work. .6 CAN/CGSB_69.29/ANSI/BHMA A156.13, Mortise Locks and Latches. .1 Wall mounted, waterless. .2 Notify the Consultant, in writing through the Consultant, of any defects or 4. MAINTENANCE DATA .7 CAN/CGSB_69.31/ANSI/BHMA A156.15, Closer/Holder Release Device. .1 Urinal: vitreous china, waterless, replaceable cartridge, back outlet. imperfections that would adversely affect the installation and intended .8 CAN/CGSB_69.32/ANSI/BHMA A156.16, Auxiliary Hardware. .2 Acceptable manufacturers: Falcon or approved equal function of the items. .9 CAN/CGSB_69.34/ANSI/BHMA A156.18, Materials and Finishes. .1 Submit maintenance data and manual for specified washroom accessories .3 Starting work will be interpreted as acceptance of completed work by others complete with related necessary maintenance tools. .10 Toilet Electronic Flush Valves: .10 CAN/CGSB_69.36/ANSI/BHMA A156.20, Strap and Tee Hinges and .4 Carefully examine the drawings and specifications and coordinate this work .1 Surface mounted, controlled by sonic or infra_red or light sensitive Hasps. with all related sections of work. 5. WASHROOM ACCESSORIES occupancy detector. .1 Complete with removable filter, 9 second time delay, flush time 2. HARDWARE LIST adjustable from 0_8 seconds, factory set at 4.5 seconds, 4.5 L The following coded items shall be as manufactured by BROAN, or approved The following coded items shall be as manufactured by Bobrick, or approved substitution, unless specifically noted otherwise. Refer to drawings for locations. .1 Submit contract hardware list to owner. flush/cycle maximum. substitution, unless specifically noted otherwise. Refer to drawings for locations. .2 Indicate specified hardware, including make, model, material, function, size, .2 Sensor adjustable from 50_1220 mm, factory set to 860 mm. .1 EF-1 - Model L150L (min 148 cfm capacity) finish and other pertinent information. .3 Solenoid valve: 24 VAC slow_closing type for 60 kPa (minimum), .1 Toilet Tissue Dispensers .3 Use matching hardware in #619 Satin Nickel. Alternative acceptable upon 1000 kPa (maximum), 185 degrees F with manual over_ride, a) Surface mounted _Double B_2892 approval by Engineer/owner. adjustable flow control. .2 EF-2 - Model L200L (min 214 cfm capacity) .2 Paper Towel Dispensers .4 Transformer: 120/ 24 VAC Class 2, CSA listed, hardware box type a) Surface mounted- dispenser- motion sensor type B_72974 3. CLOSEOUT SUBMITTALS .2 Acceptable manufacturers: Delta, Sloan, Kohler 3. PREPARATION .3 Soap Dispenser .1 Provide operation and maintenance data for door closers, locksets, to owner .11 Washroom Lavatories: a) Surface mounted _ dispenser- motion sensor type B_ 2012 .1 Coordinate allbulkhead requirements with related work sections. .2 Brief maintenance/operation staff regarding proper care, cleaning, and .1 Counter_top: .4 Mirrors - S.S. framed - Fixed B-165 general maintenance. .1 Porcelain_on_steel, self_rimming, with front overflow, soap .2 Examine all prepared conditions prior to start of installation and assure Fixed tilt gapless fit B-293 depressions, gasket, swivel clamps, semi_oval bowl, one supply prepared blocking/support is rigidly in place. .5 Robe Hooks RSHQLQJ6L]Hó´[ò´ 4. EXTRA MATERIALS a) Single B_671 .2 Acceptable manufacturers: Kohler, American standard, Crane, Acorn, 4. INSTALLATION .1 Supply two sets of wrenches for door closers, locksets. .6 Grab Bars _ c/w peened grip Series B-6806 .12 Washroom Lavatory Electronic Trim: 5 DOOR HARDWARE a) Water closet B_5806 x 1070 .1 Barrier_free electronic faucet: .1 Install all washroom fans specified and indicated on the drawings in .1 Locks and latches: c) Water closet _ horizontal B_5806 x 1070 accordance with manufacturer's written recommendations .7 Hand Dryer: recessed B-750 115V

PROJECT No. 082183 VICTORY HALL SCALE AS SHOWN VILLAGE OF KEREMEOS 0 02/27/14 D.D. S.R. ISSUED FOR TENDER DRAWN PM WASHROOM RENOVATION B 08/21/12 D.D. S.R. ISSUED FOR PRICING VILLAGE OF DESIGNED PM A 08/02/12 D.D. S.R. ISSUED FOR FINAL CLIENT REVIEW

NO. DATE ENG. BY SUBJECT DRAWING NUMBER REV. NO. SHEET KEREMEOS KEREMEOS GENERAL NOTES & SPECIFICATIONS SHEET 2 REVISIONS 5 20122108-1-205 0 6 ELECTRICAL SPECIFICATIONS:

1. ALL WORK SHALL COMPLY WITH THE CANADIAN ELECTRICAL CODE, LOCAL BYLAWS AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. LEGEND 2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE. ALL VAULT, JB, CONCRETE BASES M M AND LTG. SYMBOLS ARE NOT TO SCALE. 3. ALL MANUFACTURE AND CSA LABELS SHALL BE VISIBLE AND LEGIBLE AFTER THE EQUIPMENT IS INSTALLED. SOV XFMR 4. ALL EQUIPMENT AND MATERIAL SHALL BE CSA CERTIFIED. 120V/12V CONTROL TRANSFORMER MOUNTED IN WALL CUT OUT 5. NO WORK SHALL INTERFERE WITH OTHER CONSTRUCTION ACTIVITIES IN THE AREA. BOX. 120V/12V 6. THE CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT PRIOR TO COMMENCEMENT OF WORK AND SHALL PAY ALL ASSOCIATED FEES. 7. THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER OF CHANGES REQUIRED BY THE ELECTRICAL INSPECTION DEPARTMENT PRIOR TO MAKING CHANGES. M CEILING FAN 8. THE CONTRACTOR SHALL SUPPLY COPIES OF ALL INSPECTION REPORTS TO THE ELECTRICAL ENGINEER WITHIN 24 HOURS OF INSPECTION. 9. THE CONTRACTOR SHALL FURNISH CERTIFICATES OF ACCEPTANCE FROM ELECTRICAL INSPECTION DEPARTMENT ON COMPLETION OF WORK TO THE ELECTRICAL ENGINEER. VALANCE LIGHT; NEO-RAY 22DIW STRAIGHT AND 10. INSTALLATION OF ALL EQUIPMENT SHALL INCLUDE ALL NECESSARY CONNECTORS, TERMINATIONS, NARROW 3' 1-T5 OR EQUIVALENT FASTENERS AND BONDING REQUIRED TO CREATE A FULLY FUNCTIONAL SYSTEM. 11. ALL CONDUCTORS SHALL BE STRANDED COPPER, RW90 XLPE INSULATED OR OTHERWISE NOTED. 12. ALL GROUNDING AND BONDING SHALL COMPLY WITH THE CANADIAN ELECTRICAL CODE. 13. ALL CONDUCTORS SHALL BE IDENTIFIED IN ALL JUNCTION BOXES, CABINETS OR OTHER ACCESS CEILING MOUNTED LIGHT; COOPER SHAPER 102-S SERIES 24" POINTS. IDENTIFY WIRING WITH PERMANENT INDELIBLE IDENTIFYING MARKINGS, EITHER NUMBERED 3-26W CFL OR EQUIVALENT AND/OR COLOUR CODED PLASTIC TAPE ON BOTH ENDS OF PHASE CONDUCTORS OF FEEDERS AND BRANCH CIRCUIT WIRING, PRINTED USING A THERMAL HEAT TRANSFER SYSTEM. 14. IDENTIFY GROUPS OF CONDUCTORS OR WIRES IN ENCLOSURES AND PANELS USING BRADY #B-342 RECEPTACLE MOUNTED UNDER COUNTER FOR AUTOMATIC (HEAT SHRINK SLEEVES) OR APPROVED ALTERNATE. IDENTIFY WIRES OR GROUPS OF CONDUCTORS IN SOV SOV SOV SOV M FAUCET CONNECTION JUNCTION BOXES USING BRADY #B-109 (TY-WRAP STYLE MULTIPURPOSE IDENTIFICATION TAG) OR XFMR APPROVED ALTERNATE. 15. ALL EMPTY CONDUITS SHALL BE CAPPED AND HAVE PULL STRINGS. 120V/12V 16. THE CONTRACTOR SHALL NOT USE ANY FACTORY BENDS IN THE CONDUIT RUNS EXCEPT WHERE SHOWN ON THE DRAWINGS OR APPROVED BY THE ELECTRICAL ENGINEER IN THE WHERE FACTORY 90 ABOVE COUNTER GROUND FAULT (GFCI) RECEPTACLE SOV DEGREE BENDS ARE APPROVED, THE RADIUS SHALL BE GREATER THAN 900mm FOR CONDUIT 53 M DIAMETER OR LARGER. 17. ALL EQUIPMENT LOCATIONS SHALL BE LAID OUT BY THE CONTRACTOR AND REVIEWED BY THE ELECTRICAL ENGINEER PRIOR TO INSTALLATION. SOV AUTOMATIC FLUSH TOILETS/URINALS SOLENOID 18. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY BENDS, COUPLINGS, REDUCERS, BELL END FITTINGS, PLUGS, CAPS AND ADAPTORS OF THE SAME PRODUCT MATERIAL AS THE CONDUIT TO ENSURE A COMPLETE INSTALLATION. 19. FOR WIRING INSTALLATION IN DUCTS, CONTRACTOR SHALL USE THE FOLLOWING PROCEDURE: M WALL MOUNTED OCCUPANCY SENSOR. WATTSTOPPER - INSTALL WIRES AS INDICATED IN DUCTS. UW-200 CONFIGURE FOR: - DO NOT PULL SPLICED WIRES INSIDE DUCTS. - AUTO ON (BOTH RELAYS) - INSTALL MULTIPLE WIRES IN DUCT SIMULTANEOUSLY. - 15 MIN OFF DELAY - USE CSA APPROVED LUBRICANTS OF TYPE COMPATIBLE WITH WIRE JACKET TO REDUCE PULLING - WALK-THROUGH MODE - ON TENSION. - VISIBLE ALERT - ON - AFTER INSTALLATION OF WIRES, SEAL DUCT ENDS WITH DUCT SEALING COMPOUND. - AUDIBLE ALERTS - ON 20. FOR LOW VOLTAGE WIRE SPLICING: - REMOVE INSULATION CAREFULLY FROM ENDS OF CONDUCTORS. - MARRETTE CONNECTORS OR INSULATED MULTIPLE TAP CONNECTORS TYPE BURNDY UNITAP (BIT, EMERGENCY LIGHTING UNIT c/w BATTERY PACK, CHARGER AND BIB OR BIS) SHALL BE USED FOR POWER WIRE SPLICES. TWO HEADS - ALL WIRING SHALL BE NEATLY BUNDLED AND LABELLED IN ALL JUNCTION BOXES. 21. TESTING: - PERFORM TESTS USING QUALIFIED PERSONNEL. PROVIDE NECESSARY INSTRUMENT AND EQUIPMENT. - AFTER INSTALLING THE LOW VOLTAGE WIRING BUT BEFORE SPLICING AND TERMINATING, PERFORM INSULATION RESISTANCE TEST WITH 1000V MEGGER ON EACH PHASE CONDUCTOR. 22. CONDUITS AND JUNCTION BOX SUPPORTS, AND BRACKETS SHALL BE GALVANIZED STEEL OR STAINLESS STEEL. 23. FINAL LOCATIONS FOR THE ELECTRICAL EQUIPMENT SHALL BE ADJUSTED UPON APPROVAL BY THE ELECTRICAL ENGINEER. 24. ALL ALUMINUM SPLICES SHALL HAVE PENETROX JOINT COMPOUND APPLIED. THE JOINT COMPOUND SHALL BE COMPATIBLE WITH POLYETHYLENE INSULATION (EG. PENETROX A-13). 25. SHOP DRAWINGS AND DATA SHEETS FOR ALL ELECTRICAL EQUIPMENT AND SUPPORTING ASSEMBLIES SHALL BE APPROVED BY THE ELECTRICAL ENGINEER. 26. ALL MODIFICATIONS OF ELECTRICAL EQUIPMENT AND/OR SUPPORTS (CUTTING, BENDING, , ETC.) THAT RESULTS IN DAMAGE AND/OR REMOVAL OF THE CORROSION RESISTANT COATING SHALL BE REPAIRED AND/OR RE-COATED. THE PROCESS FOR REPAIR AND/OR RE-COATING SHALL BE SUBMITTED FOR APPROVAL BY THE ELECTRICAL ENGINEER. PLAN 1/2"=1'-0" NOTES: UPDATED WASHROOM LAYOUT 1. CONTRACTOR TO PROVIDE PRICING FOR TANKLESS AUTOMATIC FLUSH TOILET OPTION.

PROJECT No. 20122108 VICTORY HALL SCALE AS SHOWN VILLAGE OF KEREMEOS 0 02/27/14 D.D. S.R. ISSUED TENDER DRAWN LV WASHROOM RENOVATION B 08/21/12 D.D. S.R. ISSUED FOR PRICING VILLAGE OF DESIGNED LDL A 08/02/12 LDL LV ISSUED FOR FINAL CLIENT REVIEW

NO. DATE ENG. BY SUBJECT DRAWING NUMBER REV. NO. SHEET KEREMEOS KEREMEOS WASHROOM LAYOUT PLAN ELECTRICAL LAYOUT REVISIONS 6 20122108-1-601 0 6