Characterization, Analysis, and Physical Testing of Polymers

Total Page:16

File Type:pdf, Size:1020Kb

Characterization, Analysis, and Physical Testing of Polymers CHARACTERIZATION, ANALYSIS, AND PHYSICAL TESTING OF POLYMERS LABORATORY PRACTICAL WORKNOTE STUDENT NAME:__________________________________________________ MATRICULATION NUMBER:_______________________________________ ACADEMIC SESSION: _____________________________________________ CLASS:___________________________________________________________ DATE: ____________________________________________________________ Compiled by: Ekebafe, L.O. Oladebeye, A.O. 1 Points to remember while performing the experiment in a real laboratory: 1. Always wear laboratory coat and gloves when you are in the laboratory. When you enter the laboratory, switch on the exhaust fan and make sure that all the chemicals and reagents required for the experiment are available. If it is not available, prepare the reagents using the components for reagent preparation. 2. Make sure you do not use an unknown reagent. Do not assume that all plastic containers contain water. 3. Cover-shoe or, preferably, safety boots should be put on to ensure safety of the feet. 4. Make sure to clean all your working apparatus with chromic acid and distilled water and ensure that all the apparatus are free from water droplets while performing the experiment. 5. Make sure to calibrate the electronic weighing balance before taking the measurements. 6. Ensure that the stop watch and hot air gun are working properly. 7. Clean all glass wares with soap and distilled water. Once the experiment is completed, recap the reagent bottles. Switch off the light, and exhaust fan before leaving the laboratory. 8. Discard the used gloves in a waste bin. 2 EXPERIMENT 1 Determination of Molecular Weight by Dilute Solution Viscometry Intrinsic Viscosity Measurements Practical Date:_________________________________________________ Aim/Objectives 1. Determine the absolute viscosity of Polymer solutions of different concentrations 2. Determine the viscosity average molecular weight of a polymer. Theory One of the most important parameters in molecular characterization is the determination of the average molecular weight of the polymer chain. One of the simplest and most widely used methods for molecular weight determination is dilute solution capillary viscometry. In this experiment, the molecular weight of a commercial polystyrene sample of industrial grade polymers will be determined. The background information for this laboratory session can be found in the references given below. Viscosity is an internal property of a fluid that offers resistance to flow. It is due to the internal friction of molecules mainly depends on the nature & temperature of the liquid. Many methods are available for measuring viscosity of polymer solution. The Ostwald method is a simple method for the measurement of viscosity, in which viscosity of liquid is measured by comparing the viscosity of an unknown liquid with that of liquid whose viscosity is known. In this method viscosity of liquid is measured by comparing the flow times of two liquids of equal volumes using same viscometer. Consider two liquids are passing through a capillary of same viscometer. Then the coefficient of viscosity of liquid (η2) is given by equation: Here, t1 and t2 are the time of flow of the liquids and ρ1 and ρ2 are the respective densities. And η1 is the coefficient of viscosity of water. For a given liquid η has a specific value at the same temperature. Various mixtures of two non-interacting liquids viscosities will lie among the viscosities of those pure components. The time of flow of liquid depends on the viscosity and composition. In this method the flow times are measured for different known compositions and a graph is plot for time of flow and compositions. The unknown composition can be determined by plotting a graph for the time of flow and compositions. The molecular weight of the polymer is measured by using viscometer and the molecular weight obtained by this technique is called viscosity average molecular weight. The molecular weight of the polymer solution is very high so the viscosity of polymer solution is very high compared to that of pure solvent. 3 From the Mark-Houwink equation the relationship among the molecular weight and viscosity are given below: where, [η] is the intrinsic viscosity, M is Molecular weight, K and α are constants for a particular polymer solvent system. If we know the K and α values for a given polymer solution the intrinsic viscosity and molecular weight can be calculate using the above equation. Materials Required 1. Safety glasses for all group members at all times. 2. Ubbelohde viscometer 3. 5ml or 10 ml pipette and a plastic pipetter 4. Stopwatch 5. Ring stand and appropriate clamps 6. 25 ml volumetric flask 7. solvent (common PS solvents are Toluene and THF) 8. Polystyrene Sample Procedure 1. In the Polymer Handbook find the section on Viscosity-Molecular Weight Relationships and look up the Mark-Houwink-Sakurada (MHS) parameters for polystyrene in a variety of solvents. Pick a "good" solvent for PS in which to conduct the experiment. How does one determine the "goodness" of solvent from the MHS parameters? 2. Once the solvent is chosen, calculate the starting concentration for the dilute solution viscometry experiments. Experiments should be conducted at four (4) decreasing concentrations:. These should be made by the successive dilution method directly in the viscometer if possible. This typically leads to less experimental error than making four separate solutions, especially when small sample weights are involved. What is the "drawback" to this method? NOTE: Make certain to mix the diluted samples well in the viscometer and always run the new solution up through the capillary once before taking data. 3. Select Ubbelohde viscometer to do the experiment. Which viscometer are you using? What do you expect to be the difference?). The viscometer should first be rinsed thoroughly (including the capillary bore) with the solvent to be used before starting the experiment. 4. Flow Time Measurement 5. Follow the instructions below for performing a flow time measurement (a demonstration will be given). With reference to the diagram in the polymer handbook, a. Load 8 ml of solvent into tube 1 (reservoir B) using the pipette. b. Attach the pipette to the top tube 2 and cover the hole of tube 3 (sidearm) with your thumb. 4 c. With the sidearm firmly blocked, suck the solvent up into reservoirs A, C, and D (just past the upper mark). Remove the pipette from tube 2, then remove your finger from the sidearm. NOTE: You must remove the pipette BEFORE taking your finger off the sidearm! d. Measure the flow time for the solution (solvent or polymer). The flow time of interest is the time for the meniscus to pass from the upper to lower marks on the capillary. Note: The choice of Viscometer # (capillary diameter) is made by the criteria of a solvent flow time greater than 60 sec. (minimum) and preferably 100 sec. Why must the solvent flow time be kept to this low value? NOTE: Repeat the measurements until you get flow times within 0.2 - 0.5 sec. If agreement is not obtained in 3-5 measurements, you may have to clean the viscometer and start over. Many times dust or other foreign material in the capillary is the cause for erratic results. Once at least three (3) consistent flow times have been obtained, go on to the next dilution. e. Once the next dilution is done or the next solution is loaded in the viscometer allow it to equilibrate for 3-5 minutes, then run the new solution through the capillary at least two (2) times before taking your next set of readings. f. When the experiment is complete, thoroughly clean the viscometer with solvent paying particular attention to the capillary. Run the solvent flow time one more time to check for consistency with the previous measurement. (Is the solvent flow time the same as at the start of the experiment? Why not and what do you do about it?) The viscometer should be stored with tubes 1, 2, and 3 covered to prevent contamination by foreign material. Using the references provided for information, do the following for each material tested: 1) In the space provided, present a clean and neat table of your raw data, including solvent and polymer flow times, viscometer # and type, etc. 2) Calculate ηrel, ηsp, and ηinh for each concentration of each solution. 3) On the same graph, plot ηsp/c versus c and ηinh versus c. Determine [η] as the common intercept at C=0 of the best straight lines through the data (Note: Use Engineering judgment in doing the curve fit – exclude "spurious" points that are obviously not following the observed trend.) Comment on your method of determining the "best" fit of the data. Explain any differences in the intercept obtained by the two techniques. Which is more reliable or more accurate? 4) Using the value of [η] measured; calculate the molecular weight of the sample. 5) If you had to choose another solvent for polystyrene, what would it be and why? What are the MHS parameters for your alternative polymer/solvent system? HINT: You need the Polymer Handbook or equivalent on-line resource to answer this question. Discussion Questions Briefly explain, give the relationship for, or define the following: 1) Define the following viscosity terms: relative viscosity; specific viscosity; reduced viscosity; inherent viscosity; intrinsic viscosity. 2) Mark-Houwink-Sakurada (MHS) Equation. a) Explain the significance of the various terms in the equation. 5 b) Is this a "universal" equation (i.e., for any polymer/solvent system)? c) From a physical chemistry
Recommended publications
  • Catalogue of Chemical, Philosophical and Other Glassware For
    CHEMICAL GLASSWARE. PHILADELPHIA & NEW YORK 1 8 8 1 1 8 8 1 CATALOGUE OF CHEMICAL, PHILOSOPHICAL AN D OTHER GLASSWARE FOR LABORATORIES, COLLEGES, MUSEUMS, ASSAYING WORKS, INSTITUTES OF TECHNOLOGY, ACADEMIES, &c., &c. MANUFACTURED BY WHITALL, TATUM & CO., No. 410 RACE STREET, 46 and 48 BARCLAY ST., P. O. Lock Box P, P. O. Box 3814, PHILADELPHIA. N E W Y O R K . 1 8 8 1 . For a full line of G lassw are of various kinds, send for our G eneral C atalogue. CHEMICAL REAGENTS AT NET PRICES. Discount on Chemical List, pages vi.-xiv., and Bottles, x v i i i . - x x . , .................................................................................45 p e r cent. Discount on Flint Homoeopathic Vials, pages xxi.-xxiii., 25 “ “ Graduates, pages xvi., xvii., - - 25 “ Reagents, pp. iv., v.; Sundries, p. xv.; and Scales, p. xxiv. at net prices. The references by pages are to oar GENERAL CATALOGUE. ii CHEMICAL AND PHILOSOPHICAL GLASSWARE FOR Laboratories, Colleges, Museums, Assaying Works, Institutes of Technology, Academies, &c. Attention is invited to the Line of Chemical Glass Ware of our own manufacture. By purchasing this class of goods at home, instead of depending upon foreign sources of supply, the carrying of a large and expensive stock is avoided; the opportunity of effecting changes in the form of apparatus for special purposes is afforded, and promptness in filling orders greatly facilitated. Under the advice and direction of experienced chemists, we have for a number of years been perfecting our work in these lines, and now feel confident that the character both of the glass and work­ manship will be found, for all the usual needs of the Laboratory, to compare favorably with the imported wares.
    [Show full text]
  • BROOKFIELD DIAL READING VISCOMETER with Electronic Drive
    BROOKFIELD DIAL READING VISCOMETER with Electronic Drive Operating Instructions Manual No. M00-151-I0614 SPECIALISTS IN THE MEASUREMENT AND CONTROL OF VISCOSITY with offices in : Boston • Chicago • London • Stuttgart • Guangzhou BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Boulevard, Middleboro, MA 02346 USA TEL 508-946-6200 or 800-628-8139 (USA excluding MA) FAX 508-946-6262 INTERNET http://www.brookfieldengineering.com TABLE OF CONTENTS I. INTRODUCTION .....................................................................................5 I.1 Components .......................................................................................................5 I.2 Utilities ................................................................................................................6 I.3 Specifications .....................................................................................................6 I.4 Set-Up ................................................................................................................7 I.5 IQ, OQ, PQ .........................................................................................................7 I.6 Safety Symbols and Precautions .......................................................................8 I.7 Cleaning .............................................................................................................8 II. GETTING STARTED ..............................................................................9 II.1 Operation ...........................................................................................................9
    [Show full text]
  • Kimblecatalog Dwkcover Digital.Pdf
    1 ADAPTERS 223 GAS SAMPLING 16 AMPULES 226 HYDROMETERS 16 ARSINE GENERATORS 229 ISO 17 BEADS 235 JARS 18 BEAKERS 236 JUGS 21 BOTTLES 237 KITS AND LABSETS 41 BURETS 265 NMR 47 CAPS, CLOSURES, SEPTA 271 PETROCHEMICAL 59 CELL CULTURE 289 PIPETS 62 CENTRIFUGE TUBES 294 PURGE AND TRAP 71 CHROMATOGRAPHY 295 RAY-SORB 112 CLAMPS 300 ROTARY EVAPORATORS 114 CONCENTRATORS 305 SAFETY 118 CONDENSERS 319 SERIALIZED AND CERTIFIED 124 CONES 324 SLEEVES 124 CRUCIBLES 324 STARTER PACKS 125 CYLINDERS 325 STIRRERS 131 DAIRYWARE 328 STOPCOCKS AND VALVES 135 DESICCATORS 337 STOPPERS 135 DISHES 340 TISSUE GRINDERS 136 DISPENSERS 348 TUBES 136 DISSOLUTION VESSELS 365 VACUUM AND AIRLESS 137 DISTILLATION 374 VIALS 158 DRYING 389 WASHERS 159 EXTRACTION 390 WEIGHING BOATS 165 FILTRATION 391 TECHNICAL INFORMATION 179 FLASKS 433 INDEX TABLE OF CONTENTS TABLE 210 FREEZE DRYING 210 FRITTED WARE 211 FUNNELS Kimble has the products and expertise to support our customers’ workflows. We focus on providing laboratory glassware solutions from sample storage to sample disposition for market segments such as petrochemical, pharma/biotech/life sciences, environmental and food/beverage. With our breadth of products and depth of knowledge, Kimble offers everything you need to streamline your workflow and simplify everyday life in the lab. From vials and NMR tubes to barcoding services and beakers, we’ve got you—and your sample— covered from start to finish. Discover why Every Sample Deserves Kimble Sample Collection Sample Storage Sample Preparation Detection Sample Disposition
    [Show full text]
  • HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014]
    HAAKE Viscometer Standard Operating Procedure [Updated Sept 10, 2014] HAAKE Viscometer 7 R+ Location of Machine: Composites Lab, RFM 1218 Location of SOP and Machine Operating & Safety Manual: Composites Lab website under resources; Composites Lab TRACS site; and Hardcopy near machine. Emergency Contact: Call 911 Call EHS & Risk Management at 512-245-3616 Call Head Lab Technician, Dr. Ray Cook (office 512-245-2050) Call Dr. Jitendra S Tate (office 512-245-4872) Before using this machine: You must have permission from Dr. Tate. You must have received formal training from technician or, trained research student (designated by Dr. Tate) related to machine safety and operation. You must read and understand SOP and Machine Cleaning Manual. You must use this machine under direct supervision of Dr. Tate or, Dr. Cook or, trained research student (designated by Dr. Tate). You must have signed “Lab Rules” document with Dr. Tate. This document must be signed every semester fall, spring, and summer (as applicable). If you do NOT follow above instructions you will be held responsible for your own safety and damages. Safety Precautions: Protective Equipment: Prior to performing this procedure, the following personal protective equipment must be obtained and ready for use: Gloves, Safety Goggles, Face Mask, Lab Coat. Important Safeguards: 1. Prior to performing this procedure, the following safety equipment must be accessible and ready for use: (e.g. chemical fume hood, biological safety cabinet, laminar flow hood, chemical spill kits) Fume hood 2. All liquids should be drained to containers for chemical disposal and properly marked. 3. In the event that a hazardous material spill during this procedure, be prepared to clean with cleaner according to MSDS of materials used.
    [Show full text]
  • Laboratory Supplies and Equipment
    Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout
    [Show full text]
  • Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr
    Building and Validating a Rotational Viscometer Brian Cherrington & Jack Rothstein Mechanical Engineering Faculty Mentors: Dr. Maria-Isabel Carnasciali, Dr. Samuel Daniels Abstract This project was an effort to redesign an initial prototype rotational viscometer to experimentally test whether or not viscosity values vary significantly when the geometry of the viscometer is changed. The scope of the project involved designing and building a viscometer that could vary the gap between the inner and outer cylinders, variation of the testing fluid’s temperature, and control of the device’s RPM. After weeks of planning, designing, and fabrication the new viscometer was complete. In order to control the device, monitor the sensor readings, and calculate the testing fluid’s viscosity a LabVIEW program was created. Testing on medium to high viscous fluids was completed to determine if the viscosity values and the geometry of the viscometer are dependent or independent of each other. The results did show a correlation between measured viscosity and variations in the geometry of the viscometer. More testing is required to further verify the results and properly calibrate the device. Introduction For this project a new design was conceptualized, fabricated, and tested. This new design met several criteria including, Viscosity is often referred to as a fluid’s thickness or how much it resists deformation due to an applied force. Designed for future use in ME labs; Rotational viscometers measure the amount of torque needed Designed to be durable, sustainable, and easy to to rotate an object moving through fluid at a known RPM. dissemble and clean; Using the measured torque, RPM, and dimensions of the Multiple inner cylinders for varying gap sizes; device, the viscosity can be calculated using equation 1.
    [Show full text]
  • Bottlesinsmall Case for Unlimitedapplications
    BOTTLES KIMAX® media bottles are the perfect bottle for any application. The outstanding quality ensures a wide range of use, from long term storage and transporting to the most demanding applications in the pharmaceutical and food industries. Sturdy design and improved clarity allow contents and volume to be checked quickly, while temperature resistance makes the bottles ideal for autoclaving. Essential to every laboratory, KIMAX® media bottles are proven reliable for unlimited applications. We offer a wide variety of general purpose bottles in small case quantities or large bulk packs with a variety of closures. We also offer containers with or without caps attached for high use items or facilities with centralized stockrooms. Customization to meet your specific needs is simpler than ever, including pre-cleaning and barcoding. Trust DWK Life Sciences to be the exclusive source for all your laboratory glass needs. DWK Life Sciences 22 BOTTLES Clear Glass Boston Round / Amber Glass Boston Round Clear Glass Boston Round Bottles Amber Glass Boston Round Bottles Kimble® Clear Boston Rounds are made from Type III Kimble® Amber Boston Rounds are made from Type III soda-lime glass and have a narrow-mouth design. Clear soda-lime glass and have a narrow-mouth design. Amber bottles allow for viewing of contents. They come with a bottles protect light-sensitive contents. They come with a variety of caps and liner combinations and are designed variety of caps and liner combinations. They are designed to protect the quality of liquids and product storage. to protect contents from UV rays and are ideal for light- sensitive products.
    [Show full text]
  • UNIT 1 ANSWERS the Water Is Called the Solvent and the Sodium Chloride Is the Solute
    ANSWERS 345 5 ▶ Sodium chloride dissolves in water to form a solution. UNIT 1 ANSWERS The water is called the solvent and the sodium chloride is the solute. If the solution is heated to 50 °C some of the water evaporates until the solution becomes CHAPTER 1 saturated and sodium chloride crystals start to form. 1 ▶ a melting b freezing 6 ▶ a er 60 c subliming/sublimation d subliming/sublimation 50 g wat 2 ▶ a 40 30 20 10 0 solid liquid gas solubility/g per 100 0 20 40 60 80 100 120 Note: Solids should have regularly packed particles temperature/°C touching. Liquids should have most of the particles b 94 +/−1 g per 100 g touching at least some of their neighbours, but with The values obtained in this question and in c depend gaps here and there, and no regularity. Gases should on the line of best fit. In the exam there will always be have the particles well spaced. some tolerance – a range of values will be accepted. b Solids: vibration around a fixed point. Liquids: c From the graph, the solubility at 30 oC is 10 g per 100 g particles can move around into vacant spaces, but of water. with some difficulty because of the relatively close 40 ____ ​​ × 10 = 4 g packing. 100 c Evaporation: Some faster moving particles break away Therefore 4 g of sodium chlorate will dissolve. from the surface of the liquid. Boiling: Attractive forces d i 53 +/−1 °C are broken throughout the liquid to produce bubbles ii The solubility at 17 oC is 7 ±1 g per 100 g, therefore of vapour.
    [Show full text]
  • Miniav®-X Automatic Viscometer Instruction & Operation Manual
    MiniAV®-X Automatic Viscometer Instruction & Operation Manual 81.2254 i CONTENTS 1 INTRODUCTION/INSTALLATION 1 The miniAV®-X Automatic Viscometer .................................................................................. 1 Measuring kinematic viscosity ............................................................................................... 2 Safety cautions ..................................................................................................................... 2 Specifications ....................................................................................................................... 4 Installation ............................................................................................................................ 4 Required installation components ............................................................................... 4 Vacuum Pump unit connections ................................................................................. 6 Bath unit connections ................................................................................................ 6 VISCPRO® for Windows® XP® ............................................................................................ 6 Installing VISCPRO® software .............................................................................................. 7 Computer requirements ............................................................................................. 7 Windows® XP® installation .......................................................................................
    [Show full text]
  • List of Equipments in the Department (Chemical Engineering) Mechanical
    List of Equipments in the Department (Chemical Engineering) Mechanical Operation lab Fluid Mechanics Lab Heat transfer Lab Mass Transfer lab • Cyclone Separator • Reynold’s Apparatus • Double Pipe Heat Exchanger • Tray Dryer • Plate & Frame Filter Press • Bernoulli’s Theorem Apparatus • Shell & Tube Heat Exchanger • Sieve Plate Distillation Column • Vibrating Screen • Pitot Tube Apparatus • Vertical Condenser • Liquid-Liquid Extraction • Jaw Crusher • Calibration of Orifice meter, • Computerized Control Shell & • Adsorption of CO 2 • Ball Mill Venturi meter and Rota meter Tube Heat Exchanger • Steam Distillation • Roll Crusher • Coefficient of Discharge of • Thermal Conductivity of Metal • Bubble Cap Distillation Column • Rotary Vacuum filter Orifice and Mouthpiece Bar • Cooling Tower • Fluidized Bed • Film & Drop Wise Condensation • Diffusivity Apparatus • Single Effect Evaporator • Fluidized Bed Dryer • Simple Steam Distillation • Simple Distillation • VLE Apparatus • Equilibrium Flash Distillation • Humidification & Dehumidification • Refractometer Process Control Lab Chemical Reaction Engg. Lab Fuel Combustion Energy Technology Lab Environmental Lab • Process Training Simulator with • Plug Flow Reactor • Flash & Fire Point Apparatus • BOD Incubator Modules (Software) • Isothermal Batch Reactor • Aniline Point Apparatus • pH Meter • Pressure Control System • Single Tube Packed Bed Reactor • Orsat Gas Analysis Apparatus • Sedimentation Apparatus • Flow Control System • RTD in CSTR / Mixed flow • Redwood Viscometer • UV-VIS Spectrophotometer • pH control System Reactor • Bomb Calorimeter • DO Meter • Real Time Simulator Trainer • RTD in Tubular Reactor • Smoke Point Apparatus • Digital Conductivity Meter • Level Control System • Adiabatic Batch Reactor • Temperature Control System • Distillation Column • Two Tank Interacting system • Two Tank Non-Interacting System • CSTR Control System Research Equipments • UV-Spectrophotometer • Gas Chomatography .
    [Show full text]
  • Investigation I: Graphical Determination of a Physical Value
    2018-19 Chemistry 120/ Compound Prep & Analysis/Procedure 1 Investigation 3: Preparation and Analysis of a Compound Focus Questions: How can we determine the empirical formula of the potassium iron oxalate compound synthesized in lab? What is the percent yield of the synthesis reaction? Background Synthesizing compounds in the laboratory – especially those that are new, medically useful, or brightly colored – is an exciting facet of chemistry. However, determining the chemical formula of the compound produced can be a challenge. In this series of investigations, you will synthesize a complex compound and then use several techniques to determine the empirical formula of the compound. Overview The compound that will be synthesized has the general formula KaFeb(C2O4)c · dH2O, where a, b, c, and d, are integers that give the relative molar quantities of each component in the compound. The synthesized compound will be isolated by filtration and then analyzed for percent potassium, percent oxalate, and percent water, all over a period of several weeks. The percent iron will be found by difference once the percentages of the other three components are known. These percentages will then be used to calculate the empirical formula of the synthesized compound. Percent potassium determined by ion exchange Percent water determined followed by acid-base by dehydration titration KaFeb(C2O4)c · dH2O Percent iron determined by Percent oxalate determined difference after other three by reaction with cerium percentages are known Synthesis and Isolation of the Compound Preparation of NaOH Solution, Dehydration and Analysis for Potassium Pre-lab required reading Chemistry; an Atoms-Focused Approach: Sections 7.3-7.5, 7.7, and 8.5 – 8.8.
    [Show full text]
  • Department of Chemical Engineering
    DISTILLATION FLASK : Made of borosilicate glass is specified dimension. Capacity: 125 ml. GRADUATED RECEIVER: Capacity : 100 ml. sub-division 1 ml. the cylinder is made of heat resistance borosilicate glass. FLASK SUPPORT ASSEMBLY BOARD: Three asbestos board on each with centre hole 32 mm, 37.5 mm and 50 mm. are provided. TEMPERATURE CONTROLLER: By solid state variable heat controller. Complete Apparatus as described above but supplied with 3 Nos. flask support boards and glassware for operation on 220/230 V, 1ph, 50 c/s, A.C. mains. SPARES FOR ABOVE DISTILLATION APPARATUS: 1. Distillation Flask, borosilicate glass, Capacity : 125 ml. packet of 2(two) pieces. 2. Receiver, 100 ml. packet of 2(two) pieces . 3. Thermometer : Mercury-in-Glass, with NABL Certificate IP – 5C, packet of two pieces.; IP – 6C, packet of two pieces; ASTM – 7C, packet of two pieces. ASTM – 8C, packet of two pieces. 4. Heating Element, packet of two pieces. …………….. 5. Flask support plate, packet of one each (Total 3 nos.) 32 mm. Centre Hole; 37.5 mm. Centre Hole; 50 mm. Centre Hole 2. FLASH POINT PENSKY MARTENS (CLOSED) CONFORMS TO : IS: 1448 & 1209 – 58, IP: 34, ASTM: D-93 SPECIAL FEATURES: Cup & Cover with ebonite handle for operating at high Temperature. For determining the flash point of petroleum products having a flash point above 120º C (48.89º F). The instrument which will give trouble free service under continuous operating conditions. The cast iron air bath is fitted with heaters for uniform heating. An enclosed safety type heater made of nichrome heating element. Temperature is controlled by Digital Temperature Indicator cum controller which ensure smooth and easy control of the temperature.
    [Show full text]