Matching the Sensible Heat Ratio of Air Conditioning Equipment with the Building Load SHR

Total Page:16

File Type:pdf, Size:1020Kb

Matching the Sensible Heat Ratio of Air Conditioning Equipment with the Building Load SHR Matching the Sensible Heat Ratio of Air Conditioning Equipment with the Building Load SHR Final Report to: Airxchange November 12, 2003 Report prepared by: TIAX LLC Reference D5186 Notice: This report was commissioned by Airxchange on terms specifically limiting TIAX’s liability. Our conclusions are the results of the exercise of our best professional judgement, based in part upon materials and information provided to us by Airxchange and others. Use of this report by any third party for whatever purpose should not, and does not, absolve such third party from using due diligence in verifying the report’s contents. Any use which a third party makes of this document, or any reliance on it, or decisions to be made based on it, are the responsibility of such third party. TIAX accepts no duty of care or liability of any kind whatsoever to any such third party, and no responsibility for damages, if any, suffered by any third party as a result of decisions made, or not made, or actions taken, or not taken, based on this document. TIAX LLC Acorn Park • Cambridge, MA • 02140-2390 USA • +1 617 498 5000 www.tiax.biz Table of Contents TABLE OF CONTENTS............................................................................................................................ I LIST OF TABLES .....................................................................................................................................II LIST OF FIGURES .................................................................................................................................III 1. INTRODUCTION ......................................................................................................................... 1-1 1.1. THE MYTH OF THE DECLINING LATENT CAPACITY OF UNITARY AIR CONDITIONERS ................. 1-1 1.2. BUILDING HUMIDITY CONTROL PROBLEMS ARE NOT A MYTH .................................................... 1-2 1.3. THE RATIO OF SENSIBLE AND LATENT COOLING LOADS IN BUILDINGS HAS CHANGED.............. 1-3 1.4. OPTIONS FOR INCREASING THE LATENT CAPACITY ..................................................................... 1-5 2. THE EVOLVING SENSIBLE HEAT RATIO OF COMMERCIAL BUILDINGS................ 2-1 2.1. SENSIBLE AND LATENT COOLING LOADS .................................................................................... 2-2 2.2. CHANGING BUILDING ENERGY EFFICIENCY AND VENTILATION STANDARDS – ASHRAE STANDARD 90.1 AND ASHRAE STANDARD 62 .................................................................................... 2-3 2.2.1. Building Envelope ............................................................................................................. 2-4 2.2.2. Equipment Loads............................................................................................................... 2-5 2.2.3. Ventilation and Infiltration................................................................................................ 2-6 2.3. BUILDING COOLING LOAD CALCULATIONS FOR A RANGE OF CLIMATE ZONES ................................ 2-8 2.3.1. The Evolution of Envelope and Lighting Specifications Over Time.................................. 2-9 2.3.2. Analysis Results................................................................................................................. 2-9 3. THE SYSTEM SENSIBLE HEAT RATIO OF COMBINATIONS OF HVAC EQUIPMENT 3-1 3.1. SYSTEM SHR – GENERAL CASE.................................................................................................. 3-1 3.2. SYSTEM SHR – UNITARY AIR CONDITIONER COMBINED WITH AN AIR TO AIR ENTHALPY RECOVERY EXCHANGER ....................................................................................................................... 3-2 3.2.1. Example Calculation of Combined SHR for Unitary and ERV ......................................... 3-3 3.2.2. Illustrative Example – the Example Office Building of Section 2.3................................... 3-4 3.2.3. Sensitivity Analysis............................................................................................................ 3-6 3.2.3.1. Infiltration....................................................................................................................................3-6 3.2.3.2. ERV Latent Effectiveness < ERV Sensible Effectiveness ...........................................................3-8 3.2.4. Calculation of Unitary + ERV SHRs for the Examples in Section 3.2.2 ........................... 3-8 4. SUMMARY OF KEY FINDINGS ............................................................................................... 4-1 5. CONCLUSIONS............................................................................................................................ 5-1 6. REFERENCES .............................................................................................................................. 6-1 i List of Tables Table 2-1: Changing Minimum Outdoor Make-Up Air Ventilation Rates Per ASHRAE Standard 62 ............................................................................................................2-7 Table 2-2: Required CFM/ft2, Based on Estimated Maximum Occupancy and Required CFM/Person .................................................................................2-7 Table 2-3: Weighted Average Ventilation per Floorspace Required for Office Building ................................................................................................................................2-9 Table 2-4: Input Values of the Envelope ....................................................................2-11 Table 2-5: Design Conditions .....................................................................................2-11 Table 3-1: Combined SHR Calculation ........................................................................3-4 Table 3-2: Comparison of the Building Cooling Load SHR with the Combined Unitary + ERV SHR in Miami Climatic Conditions ................................................3-5 Table 3-3: Comparison of the Building Cooling Load SHR with the Combined Unitary + ERV SHR in Boston Climatic Conditions................................................3-5 Table 3-4: Sensitivity Analysis – Impact of Infiltration (at 0.5 Air Changes/Hour) ....3-7 Table 3-5: Sensitivity Analysis: ∈latent = ∈sens –0.05 (Unitary SHR = 0.75) ................3-8 Table 3-6: Ventilation Portion of Design Load, Corresponding ERV Net Recovery Capacity at ∈=0.7 ........................................................................................3-8 Table 3-7: Design Load and Unitary Capacity Net of the ERV NRC ..........................3-9 Table 3-8: Combined SHR (Unitary SHR = 0.75)........................................................3-9 ii List of Figures Figure 1-1: Airstream Temperature Passing Through Evaporator Coil.........................1-2 Figure 1-2: Indoor RH vs. Building Cooling Load SHR with Conventional Unitary Air Conditioning Equipment........................................................................................1-5 Figure 2-1: ASHRAE 90.1 Maximum Wall Assembly “U” Values, Over Time .........2-4 Figure 2-2: ASHRAE 90.1 Maximum Roof "U" Values Over Time ...........................2-5 Figure 2-3: ASHRAE 90.1 Maximum Solar Heat Gain Coefficient Over Time..........2-5 Figure 2-4: ASHRAE 90.1 Maximum Lighting Power Density (for Office Space) and Estimated Office Equipment Power Density .........................................................2-6 Figure 2-5: Model Office Building Configuration........................................................2-8 Figure 2-6: Area Plot of Basic Constituents of the Sensible and Latent Cooling Loads – Miami / Latent Design Day / 1st Floor North Zone / 1981-1989 ........................2-10 Figure 2-7: Area Plot of Basic Constituents of the Sensible and Latent Cooling Loads – Miami / Latent Design Day / 1st Floor North Zone / 1989-1999 ........................2-10 Figure 2-8: Building Load SHR from 1975 – Present, at Sensible Design Condition (High Outdoor Temperature) ...............................................................................2-12 Figure 2-9: Building Load SHR from 1975 – Present, at Latent Design Condition (High Outdoor Humidity)...............................................................................................2-12 Figure 2-10: Building Load SHR from 1975 – Present, at Shoulder or Part Load Condition (High Outdoor Humidity, Moderate Temperature ) ...........................2-13 Figure 3-1: Unitary Air Conditioner with a Factory Integrated AAHX ........................3-2 Figure 3-2: Comparison of the Building Cooling Load SHR with the Combined Unitary + ERV SHR in Miami and Boston Climatic Conditions .......................................3-6 Figure 3-3: Impact of Infiltration on the Match of the Building Cooling Load SHR with the Combined Unitary + ERV SHR (at the Latent Design Condition)..................3-7 iii Executive Summary In recent years, an increasing number of buildings and their occupants have experienced serious moisture problems including so-called “sick building syndrome”, mold growth, and occupant discomfort due to high humidity. These problems arise from both poor interior humidity control and liquid water sources such as plumbing leaks and rain water leakage. Moisture and mold problems can cause serious health problems among the occupants and reduce productivity. In extreme cases, buildings have been rendered uninhabitable. The financial consequences of these situations can be substantial
Recommended publications
  • Energy Analysis and Carbon Saving Potential of a Complex Heating
    European Journal of Sustainable Development Research 2019, 3(1), em0067 ISSN: 2542-4742 Energy Analysis and Carbon Saving Potential of a Complex Heating System with Solar Assisted Heat Pump and Phase Change Material (PCM) Thermal Storage in Different Climatic Conditions Uroš Stritih 1*, Eva Zavrl 1, Halime Omur Paksoy 2 1 University of Ljubljana, SLOVENIA 2 Çukurova Üniversitesi, TURKEY *Corresponding Author: [email protected] Citation: Stritih, U., Zavrl, E. and Paksoy, H. O. (2019). Energy Analysis and Carbon Saving Potential of a Complex Heating System with Solar Assisted Heat Pump and Phase Change Material (PCM) Thermal Storage in Different Climatic Conditions. European Journal of Sustainable Development Research, 3(1), em0067. https://doi.org/10.20897/ejosdr/3930 Published: February 6, 2019 ABSTRACT Building sector still consumes 40% of total energy consumption. Therefore, an improved heating system with Solar Assisted Heat Pump (SAHP) was introduced in order to minimse the energy consumption of the fossil fuels and to lower the carbon dioxide emissions occurring from combustion. An energy analysis of the complex heating system for heating of buildings, consisting of solar collectors (SC), latent heat storage tank (LHS) and heat pump (HP) was performed. The analysis was made for the heating season within the time from October to March for different climatic conditions. These climatic conditions were defined using test reference years (TRY) for cities: Adana, Ljubljana, Rome and Stockholm. The energy analysis was performed using a mathematical model which allowed hourly dynamics calculation of losses and gains for a given system. In Adana, Rome and Ljubljana, it was found that the system could cover 80% of energy from the sun and the heat pump coefficient of performance (COP) reached 5.7.
    [Show full text]
  • Chapter 8 and 9 – Energy Balances
    CBE2124, Levicky Chapter 8 and 9 – Energy Balances Reference States . Recall that enthalpy and internal energy are always defined relative to a reference state (Chapter 7). When solving energy balance problems, it is therefore necessary to define a reference state for each chemical species in the energy balance (the reference state may be predefined if a tabulated set of data is used such as the steam tables). Example . Suppose water vapor at 300 oC and 5 bar is chosen as a reference state at which Hˆ is defined to be zero. Relative to this state, what is the specific enthalpy of liquid water at 75 oC and 1 bar? What is the specific internal energy of liquid water at 75 oC and 1 bar? (Use Table B. 7). Calculating changes in enthalpy and internal energy. Hˆ and Uˆ are state functions , meaning that their values only depend on the state of the system, and not on the path taken to arrive at that state. IMPORTANT : Given a state A (as characterized by a set of variables such as pressure, temperature, composition) and a state B, the change in enthalpy of the system as it passes from A to B can be calculated along any path that leads from A to B, whether or not the path is the one actually followed. Example . 18 g of liquid water freezes to 18 g of ice while the temperature is held constant at 0 oC and the pressure is held constant at 1 atm. The enthalpy change for the process is measured to be ∆ Hˆ = - 6.01 kJ.
    [Show full text]
  • Heat Transfer Pathways in Underfloor Air Distribution (UFAD) Systems
    UC Berkeley HVAC Systems Title Heat transfer pathways in underfloor air distribution (UFAD) systems Permalink https://escholarship.org/uc/item/52f04592 Authors Bauman, F. Jin, H. Webster, T. Publication Date 2006 Peer reviewed eScholarship.org Powered by the California Digital Library University of California © 2006, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Vol 112, Part 2. For personal use only. Additional distribution in either paper or digital form is not permitted without ASHRAE's permission. QC-06-053 Heat Transfer Pathways in Underfloor Air Distribution (UFAD) Systems Fred S. Bauman, PE Hui Jin, PhD Tom Webster, PE Member ASHRAE Member ASHRAE Member ASHRAE Please note that the following two statements have been of cooling airflow needed to remove heat loads from a building added as a result of the peer-review process for this paper: space using the assumption of a well-mixed room air condi- Results of heat gain shown in this theoretical steady-state tion. The familiarity of designers with this relatively simple model may be greater than those found in actual practice for equation has led to a situation in which design space heat gains UFAD systems. This may be for a number of reasons that are (i.e., total room cooling loads) are considered synonymous not now understood and should be the basis for further research with return air extraction rates, and cooling airflows are found and study. from the (mixed) room-supply temperature difference, typi- cally assumed to be 11°C (20°F). In a stratified underfloor air ABSTRACT distribution (UFAD) environment, the assumption of perfect This paper reports on a modeling study to investigate the mixing is no longer valid, requiring a different way of thinking primary pathways for heat to be removed from a room with about energy flows and airflow quantities.
    [Show full text]
  • A Comprehensive Review of Thermal Energy Storage
    sustainability Review A Comprehensive Review of Thermal Energy Storage Ioan Sarbu * ID and Calin Sebarchievici Department of Building Services Engineering, Polytechnic University of Timisoara, Piata Victoriei, No. 2A, 300006 Timisoara, Romania; [email protected] * Correspondence: [email protected]; Tel.: +40-256-403-991; Fax: +40-256-403-987 Received: 7 December 2017; Accepted: 10 January 2018; Published: 14 January 2018 Abstract: Thermal energy storage (TES) is a technology that stocks thermal energy by heating or cooling a storage medium so that the stored energy can be used at a later time for heating and cooling applications and power generation. TES systems are used particularly in buildings and in industrial processes. This paper is focused on TES technologies that provide a way of valorizing solar heat and reducing the energy demand of buildings. The principles of several energy storage methods and calculation of storage capacities are described. Sensible heat storage technologies, including water tank, underground, and packed-bed storage methods, are briefly reviewed. Additionally, latent-heat storage systems associated with phase-change materials for use in solar heating/cooling of buildings, solar water heating, heat-pump systems, and concentrating solar power plants as well as thermo-chemical storage are discussed. Finally, cool thermal energy storage is also briefly reviewed and outstanding information on the performance and costs of TES systems are included. Keywords: storage system; phase-change materials; chemical storage; cold storage; performance 1. Introduction Recent projections predict that the primary energy consumption will rise by 48% in 2040 [1]. On the other hand, the depletion of fossil resources in addition to their negative impact on the environment has accelerated the shift toward sustainable energy sources.
    [Show full text]
  • Optimal Forced-Air Distribution in New Housing
    ptimal F fee ~ ir istributi n in New H usin John ~ Andrews Introduction Cooling~Load Characteristics of the Optimized House Studies of forced-air thermal distribution systems in small buildings show that significant energy losses are common A calculation of the peak cooling load in New York State in ductwork. These losses stem from several mechanisms, was performed for both a conventional house and the opti­ including duct leakage, thermal conduction through duct mized design that would replace it (Andrews et aL 1989). walls, and selective pressurization and depressurization of The conventional house was a single-story 1500 ft2 different zones of the house when the air-distribution fan 2 [140 m ] structure with R-l1 insulation in the wans, R-20 is operating. One way to reduce or eliminate duct losses is in the ceiling, unshaded window area 15 % of the south to place the ductwork within the conditioned space, rather wall and 10% of the other wans, and an average summer­ than the more usual attic, crawlspace, or basement loca­ time air infiltration rate of 0.7 air changes per hour tions. This approach is encouraged by new standards such (ACH) .. Calculated heat gains from various sources are as ASHRAE 90.2. shown in the first column of Table 1e Duct losses equal to 30% of the cooling input are assumed here, within the A major impediment to this solution is the size and range of recent results (Cummings and Tooley 1989, unsightliness of the ductwork. If ducts could be made Modera et ale 1991). smaller in cross section, builders might be motivated to them within the conditioned space.
    [Show full text]
  • Psychrometrics Outline
    Psychrometrics Outline • What is psychrometrics? • Psychrometrics in daily life and food industry • Psychrometric chart – Dry bulb temperature, wet bulb temperature, absolute humidity, relative humidity, specific volume, enthalpy – Dew point temperature • Mixing two streams of air • Heating of air and using it to dry a product 2 Psychrometrics • Psychrometrics is the study of properties of mixtures of air and water vapor • Water vapor – Superheated steam (unsaturated steam) at low pressure – Superheated steam tables are on page 817 of textbook – Properties of dry air are on page 818 of textbook – Psychrometric charts are on page 819 & 820 of textbook • What are these properties of interest and why do we need to know these properties? 3 Psychrometrics in Daily Life • Sea breeze and land breeze – When and why do we get them? • How do thunderstorms, hurricanes, and tornadoes form? • What are dew, fog, mist, and frost and when do they form? • When and why does the windshield of a car fog up? – How do you de-fog it? Is it better to blow hot air or cold air? Why? • Why do you feel dry in a heated room? – Is the moisture content of hot air lower than that of cold air? • How does a fan provide relief from sweating? • How does an air conditioner provide relief from sweating? • When does a soda can “sweat”? • When and why do we “see” our breath? • Do sailboats perform better at high or low relative humidity? Key factors: Temperature, Pressure, and Moisture Content of Air 4 Do Sailboats Perform Better at low or High RH? • Does dry air or moist air provide more thrust against the sail? • Which is denser – humid air or dry air? – Avogadro’s law: At the same temperature and pressure, the no.
    [Show full text]
  • A Critical Review on Thermal Energy Storage Materials and Systems for Solar Applications
    AIMS Energy, 7(4): 507–526. DOI: 10.3934/energy.2019.4.507 Received: 05 July 2019 Accepted: 14 August 2019 Published: 23 August 2019 http://www.aimspress.com/journal/energy Review A critical review on thermal energy storage materials and systems for solar applications D.M. Reddy Prasad1,*, R. Senthilkumar2, Govindarajan Lakshmanarao2, Saravanakumar Krishnan2 and B.S. Naveen Prasad3 1 Petroleum and Chemical Engineering Programme area, Faculty of Engineering, Universiti Teknologi Brunei, Gadong, Brunei Darussalam 2 Department of Engineering, College of Applied Sciences, Sohar, Sultanate of Oman 3 Sathyabama Institute of Science and Technology, Chennai, India * Correspondence: Email: [email protected]; [email protected]. Abstract: Due to advances in its effectiveness and efficiency, solar thermal energy is becoming increasingly attractive as a renewal energy source. Efficient energy storage, however, is a key limiting factor on its further development and adoption. Storage is essential to smooth out energy fluctuations throughout the day and has a major influence on the cost-effectiveness of solar energy systems. This review paper will present the most recent advances in these storage systems. The manuscript aims to review and discuss the various types of storage that have been developed, specifically thermochemical storage (TCS), latent heat storage (LHS), and sensible heat storage (SHS). Among these storage types, SHS is the most developed and commercialized, whereas TCS is still in development stages. The merits and demerits of each storage types are discussed in this review. Some of the important organic and inorganic phase change materials focused in recent years have been summarized. The key contributions of this review article include summarizing the inherent benefits and weaknesses, properties, and design criteria of materials used for storing solar thermal energy, as well as discussion of recent investigations into the dynamic performance of solar energy storage systems.
    [Show full text]
  • Analysis of Cooling Load Calculations for Underfloor Air Distribution Systems
    The 13th Asia Pacific Conference on the Built Environment: Next Gen Technology to Make Green Building Sustainable , 19-20 Nov 2015 (Thu-Fri), Hong Kong. Analysis of cooling load calculations for underfloor air distribution systems Dr. Sam C. M. Hui * and Miss ZHOU Yichun Department of Mechanical Engineering, The University of Hong Kong Pokfulam Road, Hong Kong * E-mail: [email protected] Abstract Underfloor air distribution (UFAD) systems use an underfloor supply plenum located between the structural floor slab and a raised floor system to supply conditioned air through floor diffusers or terminal units directly into the building’s occupied zone. If designed properly, they have the potential to enhance energy efficiency, indoor air quality and building life cycle performance. However, the application of UFAD system is still obstructed by the information gap in some fundamental issues, such as cooling load calculation. All the cooling load calculation methods for UFAD systems nowadays have limitations and drawbacks and most building designers are not familiar with them. This research aims to investigate the cooling loads calculation methods for UFAD systems. Fundamental principles of UFAD with different configurations are studied to analyse the effects on cooling load components. Critical evaluation is made on the key factors and issues affecting the cooling load and how they differ from the overhead air distribution systems. It is found that thermal stratification, management of solar and lighting loads, architectural design and thermal properties of structural floor slab will influence the cooling load and must be evaluated carefully. It is hoped that the findings could improve the understanding of UFAD systems and provide practical information for performing the cooling load calculations and optimising the system performance.
    [Show full text]
  • Air Conditioning Clinic
    Air Conditioning Clinic Cooling and Heating Load Estimation One of the Fundamental Series April 2011 TRG-TRC002-EN Cooling and Heating Load Estimation One of the Fundamental Series A publication of Trane, a business of Ingersoll Rand Preface Figure 1 The Trane Company believes that it is incumbent on manufacturers to serve the industry by regularly disseminating information gathered through laboratory research, testing programs, and field experience. The Trane Air Conditioning Clinic series is one means of knowledge sharing. It is intended to acquaint a nontechnical audience with various fundamental aspects of heating, ventilating, and air conditioning. We have taken special care to make the clinic as uncommercial and straightforward as possible. Illustrations of Trane products only appear in cases where they help convey the message contained in the accompanying text. This particular clinic introduces the reader to cooling and heating load estimation. It is intended to introduce the concepts of estimating building cooling and heating loads and is limited to introducing the components that make up the load on a building, the variables that affect each of these components, and simple methods used to estimate these load components. It is not intended to teach all the details or latest computerized techniques of how to calculate these loads. If you are interested in learning more about the specific techniques used for cooling and heating load estimating, this booklet includes several references in the back. © 2011 Trane. All rights reserved ii TRG-TRC002-EN Contents period one Human Comfort .................................................... 1 period two Cooling Load Estimation ................................... 8 Outdoor Design Conditions ................................... 13 Conduction through Surfaces ...............................
    [Show full text]
  • Lecture 11. Surface Evaporation and Soil Moisture (Garratt 5.3) in This
    Atm S 547 Boundary Layer Meteorology Bretherton Lecture 11. Surface evaporation and soil moisture (Garratt 5.3) In this lecture… • Partitioning between sensible and latent heat fluxes over moist and vegetated surfaces • Vertical movement of soil moisture • Land surface models Evaporation from moist surfaces The partitioning of the surface turbulent energy flux into sensible vs. latent heat flux is very important to the boundary layer development. Over ocean, SST varies relatively slowly and bulk formulas are useful, but over land, the surface temperature and humidity depend on interactions of the BL and the surface. How, then, can the partitioning be predicted? For saturated ideal surfaces (such as saturated soil or wet vegetation), this is relatively straight- forward. Suppose that the surface temperature is T0. Then the surface mixing ratio is its saturation value q*(T0). Let z1 denote a measurement height within the surface layer (e. g. 2 m or 10 m), at which the temperature and humidity are T1 and q1. The stability is characterized by an Obhukov length L. The roughness length and thermal roughness lengths are z0 and zT. Then Monin-Obuhkov theory implies that the sensible and latent heat fluxes are HS = ρLvCHV1 (T0 - T1), HL = ρLvCHV1 (q0 - q1), where CH = fn(V1, z1, z0, zT, L)" We can eliminate T0 using a linearized version of the Clausius-Clapeyron equations: q0 - q*(T1) = (dq*/dT)R(T0 - T1), (R indicates a reference temp. near (T0 + T1)/2) HL = s*HS +!LCHV1(q*(T1) - q1), (11.1) s* = (L/cp)(dq*/dT)R (= 0.7 at 273 K, 3.3 at 300 K) This equation expresses latent heat flux in terms of sensible heat flux and the saturation deficit at the measurement level.
    [Show full text]
  • 0718 Psychrometrics 022 025.Pdf
    A look at the science of psychrometrics, and a real life example of how it can be used in the field to deliver lasting comfort to customers. BY CAMERON TAYLOR, CM Images courtesy of Fieldpiece Instruments Inc, unless otherwise noted. sychrometrics is simply defined as the measurement of temperature and water vapor mixtures in a given sample Pof air. It is a subject that nearly all HVAC students are taught, and many often struggle to master. It is also almost always taught in an HVAC design con- text; less so from a perspective of field analysis and trouble- shooting. Students who go on to become service technicians often wonder why they were taught psychrometrics when they perceive how seldom they use it in the field. This should not Sensible heat transfer methods (conduction, convection be so, as psychrometrics is the very foundation of HVAC, and radiation) explained visually. Image credit: Nate Adams, both in terms of design/engineering, and in field analysis. “The Home Comfort Book”. The reason we have HVAC in buildings is for human comfort, and the basis for proper HVAC design and function is psychrometrics. Understanding what is required to make Four forms of heat transfer humans comfortable indoors is also foundational for effectively The human body relies on two basic forms of heat transfer designing, installing and servicing HVAC systems. for comfort: sensible and latent heat. Within the sensible transfer form are three methods: convection, which is the Basis for human comfort transfer of heat by a fluid (such as air); conduction, which is The human body creates more heat than it needs, therefore the transfer of heat via solid objects; and radiation, which is the body will always reject this excess heat, regardless of the a transfer of heat via electromagnetic waves, such as the sun environment that surrounds it.
    [Show full text]
  • Home Heating and Cooling 2
    iowa energy center Home Series Home Heating and Cooling 2 Reduce your utility bills with low-cost, low-tech tips Get more heat from every energy dollar you spend—page 3 Make the most of your air-conditioning system—page 10 Landscape your yard for year-round comfort—page 19 Save with a whole-house approach Every year, a typical family in the United States spends around half of its home Did you know? energy budget on heating and cooling. In Iowa, that percentage can be higher, due The Energy Independence and to temperature extremes reached during the winter and summer months. Security Act of 2007 sets the Unfortunately, many of those dollars often are wasted, because conditioned air stage for significant changes in escapes through leaky ceilings, walls and foundations—or flows through energy policy across the United inadequately insulated attics, exterior walls and basements. In addition, many States for many years to come. During the next several years, new heating systems and air conditioners aren’t properly maintained or are more than energy-efficiency standards will 10 years old and very inefficient, compared to models being sold today. be put into place for appliances, As a result, it makes sense to analyze your home as a collection of systems that furnace motors, residential boilers and other energy-using devices. So, must work together in order to achieve peak energy savings. For example, you won’t watch for the latest news about tax get anywhere near the savings you’re expecting from a new furnace if your air- credits for homeowners who make handling ducts are uninsulated and leak at every joint.
    [Show full text]