HE910 at Commands Reference Guide

Total Page:16

File Type:pdf, Size:1020Kb

HE910 at Commands Reference Guide HSPA+ AT Commands Reference Guide COPYRIGHT AND TECHNICAL SUPPORT HSPA+ AT Commands Reference Guide MTSMC-H5-xx not .R1 Part Number S000528D, Revision E Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 2013, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranty with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Revisions Revision Level Date Description A 10/19/12 Initial release. B 01/31/13 Added MTCBA-H5 model to product list. C 05/06/2013 Added MTR-H6 model to product list. D 08/20/2014 Removed models that ship with newer firmware. Trademarks Multi-Tech and the Multi-Tech logo are registered trademarks of Multi-Tech Systems, Inc. Contacting Multi-Tech Knowledge Base The Knowledge Base provides immediate access to support information and resolutions for all Multi-Tech products. Visit http://www.multitech.com/kb.go. Support Portal To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com Technical Support Business Hours: M-F, 9am to 5pm CT Country By Email By Phone Europe, Middle East, Africa: [email protected] +(44) 118 959 7774 U.S., Canada, all others: [email protected] (800) 972-2439 or (763) 717-5863 World Headquarters Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, Minnesota 55112 Phone: 763-785-3500 or 800-328-9717 Fax: 763-785-9874 Warranty To read the warranty statement for your product, please visit: http://www.multitech.com/warranty.go. HSPA+ AT Commands Reference Guide 2 CONTENTS Contents Introduction ............................................................................................................................................................ 16 Formatting Conventions Overview ................................................................................................................................... 16 AT Command Syntax ......................................................................................................................................................... 16 String Type Parameters ................................................................................................................................................................... 17 Command Lines ............................................................................................................................................................................... 17 Information Responses And Result Codes ...................................................................................................................................... 18 Command Response Time-Out ....................................................................................................................................................... 19 Command Issuing Timing ................................................................................................................................................................ 19 Storing Values Set by Commands Overview ..................................................................................................................... 20 Factory Profile And User Profiles .................................................................................................................................................... 20 Format for Entering AT Commands ........................................................................................................................... 23 Command Line Prefixes ..................................................................................................................................................... 23 Starting A Command Line AT ......................................................................................................................................................... 23 Last Command Automatic Repetition A/ ...................................................................................................................................... 23 Repeat Last Command AT#/ .......................................................................................................................................................... 23 V.250 AT Commands ................................................................................................................................................ 24 Generic Modem Control ................................................................................................................................................... 24 Set to Factory-Defined Configuration &F ...................................................................................................................................... 24 Soft Reset Z ................................................................................................................................................................................... 24 Select Active Service Class +FCLASS .............................................................................................................................................. 25 Default Reset Basic Profile Designation &Y ................................................................................................................................... 25 Default Reset Full Profile Designation &P ..................................................................................................................................... 25 Store Current Configuration &W ................................................................................................................................................... 26 Store Telephone Number &Z ........................................................................................................................................................ 26 Display Stored Numbers &N.......................................................................................................................................................... 27 Manufacturer Identification +GMI ................................................................................................................................................ 27 Model Identification +GMM .......................................................................................................................................................... 27 Revision Identification +GMR ........................................................................................................................................................ 27 Capabilities List +GCAP .................................................................................................................................................................. 28 Serial Number +GSN ...................................................................................................................................................................... 28 Display Configuration and Profile &V ............................................................................................................................................ 28 Display Configuration and Profile &V0 .......................................................................................................................................... 28 S Registers Display &V1 ................................................................................................................................................................. 29 Extended S Registers Display &V3 ................................................................................................................................................. 29 Display Last Connection Statistics &V2 ......................................................................................................................................... 30 Single Line Connect Message \V ................................................................................................................................................... 30 3 HSPA+ AT Commands Reference Guide CONTENTS Country of Installation +GCI .......................................................................................................................................................... 30 DTE Modem Interface Control .......................................................................................................................................... 31 Command Echo E .......................................................................................................................................................................... 31 Quiet Result Codes Q .................................................................................................................................................................... 31 Response Format V ....................................................................................................................................................................... 32 Extended Result Codes X ..............................................................................................................................................................
Recommended publications
  • The USB to RS232 Adapter Converts a USB Port Into RS232 Serial Port Allowing You to Connect to Monitor and Control Your Serial Devices
    Model: ATZ UC232 Description: USB to RS-232 Adapter The USB to RS232 Adapter converts a USB port into RS232 serial port allowing you to connect to monitor and control your serial devices. Works with digital camera, cell phone, PDA, modem, mouse, GPS, ISDN terminal adapter etc. It is cost-effective but high performance such as remote wake-up & power-on-reset is widely recommended by serial device manufacturers. For its high durability, hot plug- and-play operation, computer OS compatibility, via data transfer rate up to 250kbps; it is most applicable to industrial environments (no IRQs requirement) and simple desktop installations. Features: • Supports full duplex asynchronous serial device to USB host • Supports various serial devices like modems, PDAs, cellular phone, digital cameras, card readers, ISDN terminal adapter etc. pg. 1 All specifications are subject to change without prior notice. © Copyright ATZ 2013 Model: ATZ UC232 Description: USB to RS-232 Adapter • Easy plug & play installation. • Fully compatible with USB specification 1.1 and 2.0 • Supports the standard RS-232 serial interface • Supports automatic handshake mode • Supports data transfer rate up to 250kbps • Supports remote wake-up and intelligent power-on-reset • Provides dual buffers for upstream and downstream data transferring • No IRQ resource required • Bus powered – no external power adapter required System Requirements - Windows 98SE/ME/2000/XP/Vista/7/8/8.1/10 or higher - Mac OS 8.6/9.x/10x or higher, Linux - AMD or Intel Pentium 133MHZ or higher graded CPU Specifications: Model No. ATZ-UC232 Chip Prolific Spee d 1.5/ 12 Mbps LED 3 Upstream USB Type A Male Connector Device DB-9 Pin Male Power Mode Bus Cable Length 1.1m Housing Molding (PVC) Package contents: 1x USB to Serial Adapter 1x CD driver Warranty: 2 Years Warranty is effective from the date of original delivery.
    [Show full text]
  • UMTS); Technical Realization of Facsimile Group 3 Non-Transparent (3GPP TS 23.146 Version 13.0.0 Release 13)
    ETSI TS 123 146 V13.0.0 (2016-01) TECHNICAL SPECIFICATION Universal Mobile Telecommunications System (UMTS); Technical realization of facsimile Group 3 non-transparent (3GPP TS 23.146 version 13.0.0 Release 13) 3GPP TS 23.146 version 13.0.0 Release 13 1 ETSI TS 123 146 V13.0.0 (2016-01) Reference RTS/TSGC-0323146vd00 Keywords UMTS ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88 Important notice The present document can be downloaded from: http://www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: https://portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI.
    [Show full text]
  • Hughes 9201 BGAN Terminal User's Guide
    Hughes 9201 User Guide P/N 3500145 Version 4.0 PTF 2b8d Copyright 2009 Hughes Network Systems, LLC. All rights reserved. This publication and its contents are proprietary to Hughes Network Systems, LLC. No part of this publication may be reproduced in any form or by any means without the written permission of Hughes Network Systems, LLC., 11717 Exploration Lane, Germantown, Maryland 20876. Hughes Network Systems, LLC., has made every effort to ensure the correctness and completeness of the material in this document. Hughes Network Systems, LLC., shall not be liable for errors contained herein. The information in this document is subject to change without notice. Hughes Network Systems, LLC. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Trademarks All trademarks, marks, names, or product names referenced in this publication are the property of their respective owners, and Hughes Network Systems, LLC. neither endorses nor otherwise sponsors any such products or services referred to herein. HUGHES and Hughes Network Systems are trademarks of Hughes Network Systems, LLC. INMARSAT is a trademark of the International Mobile Satellite Organization. The Inmarsat LOGO and the trademark BGAN are trademarks of Inmarsat (IP) Company Limited. All trademarks are licensed to Inmarsat Limited. SAFETY INFORMATION For your safety and protection, read this entire user manual before you attempt to use the Broadband Global Area Network (BGAN) Satellite Terminal. In particular, read this safety section carefully. Keep this safety information where you can refer to it if necessary.
    [Show full text]
  • Cellular Technology.Pdf
    Cellular Technologies Mobile Device Investigations Program Technical Operations Division - DFB DHS - FLETC Basic Network Design Frequency Reuse and Planning 1. Cellular Technology enables mobile communication because they use of a complex two-way radio system between the mobile unit and the wireless network. 2. It uses radio frequencies (radio channels) over and over again throughout a market with minimal interference, to serve a large number of simultaneous conversations. 3. This concept is the central tenet to cellular design and is called frequency reuse. Basic Network Design Frequency Reuse and Planning 1. Repeatedly reusing radio frequencies over a geographical area. 2. Most frequency reuse plans are produced in groups of seven cells. Basic Network Design Note: Common frequencies are never contiguous 7 7 The U.S. Border Patrol uses a similar scheme with Mobile Radio Frequencies along the Southern border. By alternating frequencies between sectors, all USBP offices can communicate on just two frequencies Basic Network Design Frequency Reuse and Planning 1. There are numerous seven cell frequency reuse groups in each cellular carriers Metropolitan Statistical Area (MSA) or Rural Service Areas (RSA). 2. Higher traffic cells will receive more radio channels according to customer usage or subscriber density. Basic Network Design Frequency Reuse and Planning A frequency reuse plan is defined as how radio frequency (RF) engineers subdivide and assign the FCC allocated radio spectrum throughout the carriers market. Basic Network Design How Frequency Reuse Systems Work In concept frequency reuse maximizes coverage area and simultaneous conversation handling Cellular communication is made possible by the transmission of RF. This is achieved by the use of a powerful antenna broadcasting the signals.
    [Show full text]
  • ISDN Terminal Adapter User Manual ISDN Terminal Adapter User Manual
    ISDN Terminal Adapter User Manual ISDN Terminal Adapter User Manual No part of this publication may be reproduced in any form by any means without the prior written permission. Other trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies. March 2001. Version 01 Contents CHAPTER 1. INTRODUCTION ...............................................................................1 Features.........................................................................................................................1 Package Checklist .........................................................................................................1 System Requirements....................................................................................................2 CHAPTER 2. BEFORE INSTALLATION................................................................3 Subscribe for an ISDN BRI (Basic Rate Interface) Line...............................................3 Collect Information about Your ISDN Line ..................................................................3 Internet Access Account................................................................................................3 Terminal Emulation Program ........................................................................................4 CHAPTER 3. CONNECTING ISDN TERMINAL ADAPTER ..............................5 Connecting Procedures..................................................................................................5 Connection
    [Show full text]
  • Digital Home Networking for Service Providers
    Digital Home Networking For Service Providers 350 E. Plumeria Drive San Jose, CA 95134-1911 USA 1-888-NETGEAR (638-4327) E-mail: [email protected] www.NETGEAR.com Today, Service Providers’ residential Customers are using their broadband data networking services in a wide variety of applications, from basic data networking via the Internet to highly advanced applications involving real time audio/video, VPN for their home office and home automation. Most get started with simple computer networking for Internet and e-mail. Then they grow over time to add more applications to this basic Digital Home Network. All these applications are fueled by the wide availability of broadband network services. Worldwide today there are roughly three hundred and fifty Million (350M) homes with broadband connections. Monaco and the Republic of Korea have digital broadband penetrations as high as ninety-three percent (93%). Eight other countries have penetration rates exceeding eighty-five percent (85%). Broadband data networking growth continues at an annual rate of sixty-five million (65M). In contrast, narrowband (dial-up) data networking is shrinking to as low as five percent (5%) of connected homes. The bulk of the applications, along with your customers’ resulting Digital Home equipment needs, however, fall into a handful of pre-configurable packages that collectively serve an extremely high fraction (95%+) of your residential Customers. Today, customers and service providers alike are furthermore hounded by time consuming tasks that are generated by: • The huge and complex set of options available for every aspect of data networking and consumer electronics • A lack of common standards for networking and product setup, interoperability and remote management • Few if any pre-documented and pre-tested setup specifications for bouquets of networking and consumer electronics equipment that are known to be interoperable with your network services as well as each element of the package These factors both frustrate and discourage all but the most tech-savvy and tenacious consumers.
    [Show full text]
  • USB to RS232 SERIAL DB9 CONVERTER USB2-VE487-TG Quick Setup Guide
    USB TO RS232 SERIAL DB9 CONVERTER USB2-VE487-TG Quick Setup Guide Table of Contents TERA GRAND USB2-VE487-TG USB TO RS232 SERIAL DB9 CONVERTER Section Topic Page A. Introduction 4 B. Installing the Drivers for the Tera Grand USB Adapter 5 C. Install and start the Prostat CONNECT Utility 7 D. Connecting the PRS-801 to your computer using the adapter 8 E. Sending the Data Points to Microsoft Excel 9 Copyright © 2014 by Prostat® Corporation. All rights reserved. Printed in the United States of America. No part of this manual may be used or reproduced in any manner whatsoever without written permission. For information contact Prostat Corporation, 1072 Tower Lane, Bensenville, IL 60106 USA Prostat is the registered trademark of Prostat® Corporation USB2-VE487-TG USB 2.0 TO RS232 SERIAL A. Introduction Converts the RS232 Serial DB9 to USB for your computer • Converts the PRS-801 connection to USB • Supports Windows 8, 7, Vista, 2000, XP, 98, Apple MAC O8 or higher, Linux 2.4.0 and later, Open- BSD 2.9 and later & FreeBSD 4.7 and later • Installed as a standard Windows COM ports, Full RS-232 modem control signals, RS-232 data signals; TxD, RxD, RTS, CTS, DSR, DTR, DCD, RI, GND • Provides instant connectivity with modems, ISDN terminal adapter, PDA, bar code scanner, label printer, and devices with DB9 SERIAL ports • Powered by USB port. Include a 33” long USB extension cable inside the package Premium High Speed USB 2.0 Serial Adapter with FTDI Chipset for NoteBook and Laptop Users. It has one Status LED and uses FTDI Chip for up to 230K Speed.
    [Show full text]
  • AT Commands Reference Guide
    SocketModem® HSDPA MultiModem® iCell MultiModem® rCell AT Commands Reference Guide Copyright and Technical Support AT Commands for Multi-Tech HSDPA Modems Embedded Wireless HSDPASocketModem® (MTSMC-H) Embedded Wireless HSDPA SocketModem® USB (MTSMC-H-U) MultiModem® iCell (MTCMR-H) MultiModem® rCell (MTCBA-H-EN2) PN S000453C, Revision C Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 2008-2010, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Revisions Revision Level Date Description A 06/30/08 Initial release (based on Siemens document version 02.050, May 9, 2008). 07/23/08 Removed voice and audio commands. B 01/15/09 Add MultiModem® iCell (MTCMR-H) and MultiModem® rCell (MTCBA- H- EN2) to the list of products that use these commands. C 03/10/10 Clarified defaults in AT&C and AT&D. Changed Technical Support statement. Trademarks MultiModem, SocketModem, and the Multi-Tech logo are registered trademarks of Multi-Tech Systems, Inc. World Headquarters Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, Minnesota 55112 Phone: 763-785-3500 or 800-328-9717 Fax: 763-785-9874 Internet Address: http://www.multitech.com Technical Support Please refer to the Copyright/Technical Support page in the product User Guide or Developer Guide.
    [Show full text]
  • HT910 E Terminal User Manual Rev
    HT910 E Terminal User Manual Rev. 2.0 Telit Module GSM & UMTS Industrial Interfaces M2M & IoT Telit Module Telit Module Important information This technical description contains important information for the installation and use of the HT910 E terminal. Read it carefully before you start working with the HT910 E terminal. We cannot be held responsible for material loss or personal injury that is due to non-compliance with the safety instructions. The warranty will be void in such circumstances. Telic reserves the right to change the included information without prior notice and does not take responsibility for errors in the document and/or for any missing information. NOTICE Please notice that the content of this User Manual only applies to the HT910 E terminal starting with serial number 06301. © Telic AG, 2017 2 Table of Contents Important information ...................................................................................................................................................... 2 1 General Information ................................................................................................................................................. 6 1.1 Contact for Support .......................................................................................................................................... 6 1.2 Conventions Used in this Manual ..................................................................................................................... 6 1.3 Related Documentation ...................................................................................................................................
    [Show full text]
  • Cellular Abbreviations
    Cellular Abbreviations AAA Authentication, Authorization and Accounting Server (RADIUS) AAL ATM Adaptation Layer ACELP Algebraic Code Excited Linear Predictive (AMR, IS-136 EFR vocoder) ACK Acknowledgement ACM Address Complete Message (ISUP) AFS AMR Full Rate Speech AGC Automatic Gain Control AGCH Access Grant Channel AHS AMR Half Rate Speech AICH Acquisition Indication Channel AK Anonymity Key AKA Authentication and Key Agreement ALCAP Access Link Control Application Part Generic name for the transport signalling protocols used to set-up and tear-down transport bearers in UMTS AM Acknowledged Mode (RLC) AMPS Advanced Mobile Phone Service AMR Adaptive Multi Rate vocoder ANM Answer Message (ISUP) API Application Program Interface APN Access Point Name (GPRS) Apps Applications ARFCN Absolute Radio Frequency Channel Number ARIB Association for Radio Industry and Business (Japan) ARP Address Resolution Protocol ARPU Average Revenue Per User ARQ Automatic Repeat Request (L2 error correction by retransmission) AS Access Stratum (UMTS) AS Application Server ASCI Advanced Speech Call Items (GSM-R) ASP Application Service Provider ATM Asynchronous Transfer Mode AVC Analog Voice Channel (AMPS) AWGN Additive White Gaussian Noise Shlomo Nizri 2 [email protected] +972-522-839905 Cellular Abbreviations B2B Business to Business BCCH Broadcast Control Channel BCFE Broadcast Control Functional Entity (UMTS, RRC) BCS Block Check Sequence BCSM Basic Call Service Model (IN) BD Billing Domain (where charging information is processed) BG Border Gateway (GPRS)
    [Show full text]
  • United States Patent (19) 11 Patent Number: 6,055,245 Mitchell Et Al
    US006055245A United States Patent (19) 11 Patent Number: 6,055,245 Mitchell et al. (45) Date of Patent: *Apr. 25, 2000 54). APPARATUS AND METHOD FOR 56) References Cited DIGITALLY CONVEYING ALERT TONES BETWEEN AN ANALOG MODEMAND AN U.S. PATENT DOCUMENTS ISDN TERMINAL ADAPTER 4,211,895 7/1980 Davis et al. ............................ 379/398 5,113,396 5/1992 Kagami ................................... 370/525 75 Inventors: Eric P. Mitchell, Ogden; Connie D. 5,711,012 1/1998 Bottoms et al. 455/557 York, Riverton; Richard A. Kunz, 5,815,505 9/1998 Mills ....................................... 370/522 Draper; Jeffrey A. Hanline, Bountiful; David M. Arnesen, West Jordan; Primary Examiner Alpus H. Hsu Gerald A. Wilson, South Jordan, all of ASSistant Examiner Afsar M. Qureshi Utah Attorney, Agent, or Firm Workman, Nydegger & Seeley 73 Assignee: 3COM Corporation, Santa Clara, 57 ABSTRACT Calif. An apparatus and method for facilitating interaction during c: a communication Session between an analog modem and a * Notice: This patent issued on a continued pros- terminal adapter for conveying digital alert tones and control ecutIOn application filed under 37 CFR data therebetween is provided. The embodiments provide 1.53(d), and is subject to the twenty year for a collateral digital communication path between a micro patent term provisions of 35 U.S.C. controller of an analog modem and a microcontroller of a 154(a)(2). terminal adapter for Selectively relaying digital alert tones and control data therebetween. One embodiment utilizes a 21 Appl. No.: 08/831,459 cellular interface of an analog modem for tapping and 1-1. evaluating information for the presence of control data.
    [Show full text]
  • Model MTA128ST-USB External ISDN Terminal Adapter
    Model MTA128ST-USB External ISDN Terminal Adapter User Guide User Guide Model MTA128ST-USB P/N 88311704 Revision E Copyright ©2000, by Multi-Tech Systems, Inc. All rights reserved. This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Record of Revisions Revision Date Description A 6/21/99 Manual released. All pages at revision A. B 9/3/99 Deleted the RJ-11 phone cord and added ISDN Configuration Utility diskette to the shipping list C 10/5/99 Added !DNn, *!DNn, !ENn, *!ENn At commands and modified S-Register S52 D 5/23/00 Added driver installation procedure for Windows 2000, added procedure for changing descriptor, deleted references to Multi-Tech’s BBS, updated area code information, added clarification to V.110 support information and made minor technical updates. E 8/3/00 Added auxiliary driver installation instructions for Windows 95/98. Trademarks MultiModemISDN, Multi-Tech, and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc. AT&T and 5ESS are registered trademarks of American Telephone and Telegraph. Microsoft, Windows, Windows 2000, Windows 98, and Windows 95 are registered trademarks of Microsoft Corporation.
    [Show full text]