Medical technology Main catalog Medicalline | Medical industry connectors STÄUBLI ELECTRICAL CONNECTORS Long-term solutions – Expert connections

Stäubli Electrical Connectors is a leading Stäubli develops, produces, sells and ser- Our customers depend on our expertise and international manufacturer of high-qual- vices products for markets with the high- our active support, even when dealing with ity electrical contacts and connector est productivity and safety standards. As unusual challenges. With Stäubli, you’re en- systems and solutions for industrial recognized specialists, our focus is always tering into a long-term partnership built on applications. We are part of the Stäubli on solutions and customers. Many new reliability, dedication, and exceptional qual- mechatronics group, the technology developments got their start here and are ity in both products and services. leader in connection solutions, robotics now becoming established as worldwide and textile machinery. standards.

Pioneering contact technology for in- distribution sector rely on our consistent, and reliability of our products are essential creased effi ciency loss-free transmission performance in all for test and measurement technology. The entire Stäubli Electrical Connectors voltage ranges. The automotive industry In the growing fi eld of alternative energy, product range meets market expectations depends on our high-effi ciency connections our products have been setting standards for high performance, the highest number for spot-welding applications in production since the 1990s. About half of the solar of mating cycles, and long-lasting reliabil- lines. Harsh conditions in the transporta- energy generated worldwide is transmitted ity for safe, durable operation. Our proven tion sector require high vibration resistance, through safe, long-lasting, high-perfor- MULTILAM technology is ideal for all types maximum reliability, and compact design. mance Stäubli connectors. of connections in industrial applications. These attributes are vitally important for rail- Customers in the power transmission and way and e-mobility applications. The safety

2 Medical technology main catalog STÄUBLI ELECTRICAL CONNECTORS Long-term solutions – Expert connections Applications and advantages

Stäubli Electrical Connectors is a leading Stäubli develops, produces, sells and ser- Our customers depend on our expertise and In the fi eld of medical technology, it is sure the highest levels of safety, reliability This catalog presents our range of connec- international manufacturer of high-qual- vices products for markets with the high- our active support, even when dealing with especially important that all components and corrosion resistance for products from tors and cables specially designed for use ity electrical contacts and connector est productivity and safety standards. As unusual challenges. With Stäubli, you’re en- be highly reliable – in intensive care units, our medical electronics portfolio. The silicon in medical devices. Alongside our stan- systems and solutions for industrial recognized specialists, our focus is always tering into a long-term partnership built on for example, people’s lives often depend and TPE used as insulation materials in our dard items, we also introduce examples of applications. We are part of the Stäubli on solutions and customers. Many new reliability, dedication, and exceptional qual- directly on the correct operation of the products can be steam-sterilized, and are pre-assembled cables. We also produce mechatronics group, the technology developments got their start here and are ity in both products and services. medical devices being used. therefore well-adapted to the specifi c re- custom solutions based on customer re- leader in connection solutions, robotics now becoming established as worldwide quirements of medical device applications. quests. Ask us for more information! and textile machinery. standards. Our decades of experience, the high-quali- The raw materials we use are carefully se- ty standards applied to all Stäubli products, lected. and our proven MULTILAM technology en-

Pioneering contact technology for in- distribution sector rely on our consistent, and reliability of our products are essential creased effi ciency loss-free transmission performance in all for test and measurement technology. The entire Stäubli Electrical Connectors voltage ranges. The automotive industry In the growing fi eld of alternative energy, product range meets market expectations depends on our high-effi ciency connections our products have been setting standards for high performance, the highest number for spot-welding applications in production since the 1990s. About half of the solar of mating cycles, and long-lasting reliabil- lines. Harsh conditions in the transporta- energy generated worldwide is transmitted ity for safe, durable operation. Our proven tion sector require high vibration resistance, through safe, long-lasting, high-perfor- MULTILAM technology is ideal for all types maximum reliability, and compact design. mance Stäubli connectors. of connections in industrial applications. These attributes are vitally important for rail- Customers in the power transmission and way and e-mobility applications. The safety

Medical technology main catalog 3 UNLIMITED POSSIBILITIES FOR CONTACT SOLUTIONS Contents MULTIL AM Technology

Page 6 General information

Page 7 Touch-protected Ø 1.5 mm and Ø 2 mm connectors

Page 9 Touch-protected Ø 1.5 mm panel-mount terminals (DIN 42802)

Page 10 Touch-protected Ø 2 mm connectors (E-DIN 42802-2)

Page 11 Touch-protected Ø 2 mm panel-mount terminals (E-DIN 42802-2) MULTIL AM are specially formed and This makes the MULTIL AM Technology the Page 13 Touch-protected Ø 2 mm resilient contact elements. All Stäubli best choice for applications with demanding adapters (E-DIN 42802-2) Electrical Connectors products benefi t requirements:

from the unique and outstanding perfor- ■ Reliable and longlife operation due to Page 14 Examples for assembled connecting leads mance of the MULTIL AM Technology. constantly high performance

with Ø 2 mm connectors (E-DIN 42802-2) Thanks to their constant spring pressure, ■ Safe operation under highest environ- MULTIL AM louvers ensure continuous con- mental demands on temperature, vibra- Page 15 Connectors and connecting leads for tact with the contact surface, resulting in a tion and shock

potential equalization according to DIN 42801 constantly low contact resistance. ■ Suitable for data and signal contacts as MULTIL AM Technology allows to fi nd solu- well as high-current connectors

Page 16 Connecting leads for potential equalization tions for connectors within the severest con- ■ Automated solutions with a high number in accordance with DIN 42801 straints and in certain products for up to 1 of mating cycles million mating cycles. Page 21 Multistrand wires for medical applications

Page 22 Tools

Page 23 Index

4 Medical technology main catalog UNLIMITED POSSIBILITIES FOR CONTACT SOLUTIONS MULTIL AM Technology

MULTIL AM are specially formed and This makes the MULTIL AM Technology the resilient contact elements. All Stäubli best choice for applications with demanding Electrical Connectors products benefi t requirements: from the unique and outstanding perfor- ■ Reliable and longlife operation due to mance of the MULTIL AM Technology. constantly high performance

Thanks to their constant spring pressure, ■ Safe operation under highest environ- MULTIL AM louvers ensure continuous con- mental demands on temperature, vibra- tact with the contact surface, resulting in a tion and shock constantly low contact resistance. ■ Suitable for data and signal contacts as MULTIL AM Technology allows to fi nd solu- well as high-current connectors tions for connectors within the severest con- ■ Automated solutions with a high number straints and in certain products for up to 1 of mating cycles million mating cycles.

Medical technology main catalog 5 General information

Length and color code Copyright Symbols For articles that are available in more than The use of this catalogue for any other pur- one length or color, please write the desired pose, in whatever form, without our prior length and color codes after the order num- written consent is not permitted. Accessories or special tools ber instead of the spaces “ ” and “*” used exist for this product. in the catalogue. RoHS ready

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n Directive 2011/65/EU on the restriction of e gu MA 20 green-yellow 26 violet the use of certain hazardous substances in The assembly instruction MA000 is electrical and electronic equipment includ- available for this product. 21 black 27 brown ing supplement pursuant to Commission 22 red 28 grey Delegated Directive (EU) 2015/863. All items listed in the catalog comply with 23 blue 29 white the requirements. 24 yellow 33 transparent Reach 25 green 34 natural Regulation (EC) No 1907/2006 for Registra- tion, Evaluation, Authorisation and Restric- Changes / Provisos tion of Chemicals. All data, illustrations and drawings in the The items listed in the catalog contain none catalogue have been carefully checked. of the substances named in Annex XVII of They are in accordance with our experience the Directive above the permissible max- to date, but no responsibility can be accept- imum concentration. Stäubli monitors the ed for errors. We also reserve the right to further development of the SVHC (sub- make modifications for design and safety stance of very high concern) and the sub- reasons. When designing equipment incor- stances named in Annex XIV. porating our components, it is therefore ad- visable not to rely solely on the data in the Surface treatment catalogue but to consult us to make sure -plated this information is up to date. We shall be Au pleased to advise you. Ni Nickel-plated

PVC Lead insulation: PVC

SIL Lead insulation: Silicone

TPE Lead insulation: TPE

Sterilizable up to 134 °C

6 Medical technology main catalog Touch-protected Ø 1.5 mm and Ø 2 mm connectors

Standard DIN 428021) lays down require- In the illustrations below the principal char- EN 61010-031 from our Test & Measureline­ ments for connectors for use in medical acteristics of these various connection product group. technology. These requirements concern systems are presented together, for com- the design of Ø 1.5 mm and Ø 2 mm con- parison, with the touch-protected Ø 2 mm nectors with regard to touch protection, ma- connection system conforming to IEC/ terial, geometry and withdrawal force.

Touch-protected Withdrawal force: ~ 3 N Ø 2 mm connecting system according to IEC/EN 61010-031

spring-loaded socket spring-loaded Ø 2 mm plug

Ø 1.5 mm rigid pin rigid socket

Application DIN 42802: Application IEC/EN 61010-031: Other relevant standards:

For the transmission of body action voltages For test and measuring applications e.g. in ■ Standard IEC 60601-1 stipulates in para- (leading away from the patient, e.g. for ECG, the electronics laboratory, where work is graph 56.3c (contact points and connec- heart monitor). carried out in a limited space with voltages tors): “Leads with conductive connection that are dangerous to touch. to a patient are constructed such that no conductive connection remote from the In addition to the connectors in accordance patient can contact earth or hazardous with DIN 42802 and E-DIN 42802-2, in this voltages.”

catalogue we also offer other Ø 1.5 mm and ■ In standard ANSI/AAMI EC53-1995 Ø 2 mm connectors. (American National Standard for ECG cables and leadwires), paragraph 4.2.1, the constructional requirements are defined to be in accordance with DIN 42802.

1) DIN 42802: “Connector, touch proof, for electromedical application”

Medical technology main catalog 7 MS1525-B MS155-B with terminals such as MEB1,5-R and ML- In-line, gold-plated Ø 1.5 mm sockets with B1,5-R). The insulating material is suitable spring-loaded ­MULTILAM for self-assembly for steam sterilization. Solder or crimp of connecting leads (compatible for mating connection.

LS1,5-B LS1,5-B

0,25 mm2 - 0,50,25 mm mm2 2 - 0,5 mm2 MS1525-B: MS1525-B:max. Ø 2,1 max.mm Ø 2,1 mm KT1525-BAKT1525-BA MS155-B: max.MS155-B: Ø 2,7 max.mm Ø 2,7 mm KT155-BA KT155-BA

Order No. Type Withdrawal force Insulation * Colors

65.3321-* MS1525-B ~ 3 N PA 21 22 23 24 25 29 Au

65.3322-* MS155-B ~ 3 N PA 21 22 23 24 25 29 Au

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MAH531 www.staubli.com/electrical

MS1525-S MLK1,5-B...). The insulating material is suit- In-line, gold-plated Ø 1.5 mm rigid plugs, able for steam sterilization. Solder or crimp for self-assembly of connecting leads connection. (compatible for mating with leads such as

S-MS1,5-SS-MS1,5-S

0,250,25 mm 2mm - 0,52 - mm0,5 2mm2 MS1525-S:MS1525-S: max. max. Ø 2,1 Ø mm2,1 mm KT2025-BAKT2025-BA MS155-S:MS155-S: max. max. Ø 2,7 Ø mm2,7 mm KT205-BAKT205-BA

Order No. Type Insulation * Colors

65.3339-* MS1525-S PA 21 22 23 24 25 29 Au

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MAH554 www.staubli.com/electrical

8 Medical technology main catalog Touch-protected Ø 1.5 mm panel-mount terminals (DIN 42802)

MEB1,5-R sockets. The terminal is pressed into pre-

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n Insulated panel terminal according to drilled panels of plastic, etc. Round e gu MA DIN 42802. With rigid, gold-plated Ø 1.5 mm connecting pin Ø 1.9 mm. Assembly instructions MAH510 pin, accepting spring-loaded Ø 1.5 mm www.staubli.com/electrical

Panel drilling

Metal panels: Ø 8,3+0,1 mm

Plastic panels: Ø 8,3-0,1 mm> 10,5 mm > 10,5 mm

Order No. Type Connection * Colors

65.3301-* MEB1,5-R Round connecting pin Ø 1.9 mm Au 21 22 23 24 25 29

MLB1,5-R sockets. The terminal is surface-mounted

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n Insulated panel terminal according to or assembled flush into predrilled panels of e gu MA DIN 42802. With rigid, gold-plated Ø 1.5 mm plastic, metal etc. Round connecting pin Assembly instructions MAH511 pin, accepting spring-loaded Ø 1.5 mm Ø 1.9 mm. www.staubli.com/electrical

Panel drilling

> 10,5 mm> 10,5 mm

Order No. Type Connection * Colors

65.3300-* MLB1,5-R Round connecting pin Ø 1.9 mm Au 21 22 23 24 25 29

Component parts

25.0021 SS4 Tube spanner 25.0023 SS2-S Tube spanner

Medical technology main catalog 9 Touch-protected Ø 2 mm connectors (E-DIN 42802-2)

MS2025-S MS205-S id insulating sleeve. The insulating material In-line, gold-plated Ø 2 mm rigid plugs, for is suitable for steam sterilization. Solder or self-assembly of connecting leads. With rig- crimp connection.

S-MS2,0-S

0,25 mm2 - 0,5 mm2 MS2025-S: max. Ø 2,1 mm KT2025-BA MS205-S: max. Ø 2,7 mm KT205-BA

Order No. Type Insulation * Colors

65.3324-* MS2025-S PA 21 22 23 24 25 29 Au

65.3314-* MS205-S PA 21 22 23 24 25 29 Au

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MAH531 www.staubli.com/electrical

MS225-B MS255-B Ø 2 mm plugs with rigid insulating sleeve for In-line, gold-plated Ø 2 mm sockets with self-assembly of connecting leads. Solder spring-loaded ­MULTILAM, accepting rigid or crimp connection.

LS2,0-B

0,25 mm2 - 0,5 mm2 MS225-B: max. Ø 2,1 mm MS255-B: max. Ø 2,7 mm KT225-BA KT255-BA

Order No. Type Withdrawal force Insulation * Colors

65.3349-* MS255-B > 10 N PA 21 22 23 24 25 29 Au

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MAH554 www.staubli.com/electrical

10 Medical technology main catalog Touch-protected Ø 2 mm panel-mount terminals (E-DIN 42802-2)

MEB2,0-R MEB2,0-L insulating sleeve. The terminals are pressed Insulated gold-plated Ø 2 mm panel into predrilled panels of plastic, metal etc. terminals with spring-loaded MULTILAM, Round connecting pin Ø 1.9 mm or solder accepting rigid Ø 2 mm plugs with rigid connection.

MEB2,0-RMEB2,0-RMEB2,0-R Ø 10 ØØ 10 10 MEB2,0-LMEB2,0-LMEB2,0-L Ø 10 ØØ 10 10 Ø 2 ØØ 2 2 Ø 2 ØØ 2 2

Panel drilling 29 29 29 28 28 28

Metal panels: Ø 8.3+0.1 mm

Ø 1.9 ØØ 1.9 1.9 Plastic panels: Ø 8.3-0.1 mm > 10,5 mm>> 10,5 10,5 mm mm

Order No. Type Withdrawal force Connection * Colors

65.3303-* MEB2,0-R > 10 N Round connecting pin Ø 1.9 mm Au 21 22 23 24 25 29

65.3331-* MEB2,0-L > 10 N Solder connection Au 21 22 23 24 25 29

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MAH528 www.staubli.com/electrical

Medical technology main catalog 11 MLB2,0-R MLB2,0-L ing rigid Ø 2 mm plugs with rigid insulating plastic, metal etc. Round connecting pin Insulated gold-plated Ø 2 mm panel termi- sleeve. The terminals are surface-mounted Ø 1.9 mm or solder connection. nals with spring-loaded MULTILAM, accept- or assembled flush into predrilled panels of

MLB2,0-RMLB2,0-R Ø 10 Ø 10 MLB2,0-LMLB2,0-L Ø 10 Ø 10 Ø 2 Ø 2 Ø 2 Ø 2

SP4 SP4 SP4 SP4 29 29 29 29 > 10,5 mm> 10,5 mm

Panel drilling

MUR/M8x0,5MUR/M8x0,5 MUR/M8x0,5MUR/M8x0,5 Ø 1.9 Ø 1.9

Order No. Type Withdrawal force Connection * Colors

65.3304-* MLB2,0-R > 10 N Round connecting pin Ø 1.9 mm Au 21 22 23 24 25 29

65.3332-* MLB2,0-L > 10 N Solder connection Au 21 22 23 24 25 29

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MAH527 www.staubli.com/electrical

12 Medical technology main catalog Touch-protected Ø 2 mm adapters (E-DIN 42802-2)

MLA2 with spring-loaded MULTILAM in insulator Adapter, made of gold-plated to fit in accepting rigid Ø 2 mm plugs with rigid in- Ø 2 mm clamping sockets. Ø 2 mm socket sulating sleeve according to E-DIN 42802-2.

Order No. Type Withdrawal force * Colors

20.0159-* MLA2 > 10 N Au 21 22 23 24 25 29

MLA2 can be locked into the socket by tightening the in insulator accepting rigid Ø 2 mm plugs Adapter, made of gold-plated brass can be grub screw. Assembled, the adapter offers with rigid insulating sleeve. screw-mounted into rigid Ø 2 mm sockets. complete touch-proof protection. Ø 2 mm The expandable Ø 2 mm plug of this adapter socket with spring-loaded MULTILAM

MLA2-S LB-I2R MLK2,0-LS/... MLA2-S LB-I2R

Non-touch-protected socket Touch protected plug connection according to E-DIN 42802-2

Order No. Type Withdrawal force * Colors

24.0159-* MLA2-S > 10 N Au 21 22 23 24 25 29

Accessories

Screwdriver: Size 00

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MA160 www.staubli.com/electrical

Medical technology main catalog 13 Examples for assembled connecting leads with Ø 2 mm connectors (E-DIN 42802-2)

Connecting lead with axial, rigid, gold-plat- ed Ø 2 mm plug. Highly flexible with TPE insulation.

Ø 2 mm plug, gold-plated, TPE insulation, moulded

Order No. Type Ø 2 mm connector / other end Lead cross section / type

55.3305- * MLK2,0-LS/P In-line plug, moulded / open lead 0.5 mm² / PLAST-E 0,50 SN TPE Au

Supplied lengths, colors, delivery times and prices on inquiry! Needless to say, we also offer variants that are not presented here – ask us!

14 Medical technology main catalog Connectors and connecting leads for potential equalization according to DIN 42801

The IEC 60364-7-710 standard requires that The Stäubli connector is specially shaped so The terminals are marked with symbol additional protective equipotential bonding as to prevent chance disconnection when be provided in all Group 1 and 2 medical used as intended, while allowing the lead to locations. be removed without the need for tools. The purpose of additional potential equal- The items for potential equalization listed in in accordance with IEC 60417-5021, and ization is to equalise potentials between the catalog take into account the require- with in the colors green-yellow. different metal parts that can be touched ments on potential equalization conductors simultaneously, or to reduce differences of set in IEC 60601-1 and are also tested ac- potential which can occur during operation cording to the DIN 42801 TÜV type. between the bodies of medical electrical de- vices and conductive parts of other objects.

TÜV Rheinland has tested this product to It verifies processes at the manufacturing verify whether it meets the relevant safety facility, including e.g. the procurement of requirements. parts (supplier evaluation), individual pro- To ensure that products that have been test- cessing steps, and inspection of finished ed and certified continue to be produced at products. the same level of quality, TÜV Rheinland inspects the production facility at regular intervals.

Relevant standards: DIN 42801: Medical standards: EC / DIN EN 60601-1: Connection bolts for equipotential bonding To place a medical device on the market in Medical electrical equipment conductors. any given country, it must be shown that the – General requirements for safety. device is safe and reliable. DIN 42801 part 2: The usual process for this involves the use IEC 60364-7-710: Equipotential bonding conductors; connec- of established international standards. Electrical installations of buildings – Re- tion sockets. For medical devices, the relevant standard quirements for special installations or loca- is IEC 60601-1 and any supplements that tions – Medical locations. apply in individual countries.

DIN EN 793 (VDE 0750 Part 211): (USA: AAMI ES 60601-1 Particular requirements for safety of medical Canada: CSA C22.2 No. 60601-1 supply units. and in EU countries: EN 60601-1)

Medical technology main catalog 15 Connecting leads for potential equalization in accordance with DIN 42801

The purpose of additional potential equali­ of potential which can occur during Our POAG socket is ­designed for screw lead zation is to equalise potentials between ­operation between the bodies of medical termination so that no special tools (crimping different metal parts that can be touched electrical devices and conductive parts ) are needed. simultaneously, or to reduce differences of other objects.

The use of high-quality components ensures The features of the new POAG socket at ■ Nickel-plated socket and gold-plated dependable potential equalization in places a glance: MULTILAM for dependable, durable where it is particularly important: in hospital ■ Screw connection is simply effected by contact facilities and medical practices. means of a standard Allen key (no spe- ■ Design in accordance with DIN 42801 We supply the new POAG socket separately cial tool needed) part 2 for the self-assembly of potential equaliza- ■ Good price-performance ratio of the tion leads, as well as leads ready assembled POAG sockets and assembled leads with this socket.

POAG-KBT6-EC/... tion. Socket made of nickel-plated brass tion for lead cross sections 4.0 mm² and Right-angled sockets for self-assembly of with MULTILAM made of gold-plated, 6.0 mm². connecting leads for potential equaliza- hard-drawn . Screw connec-

Order No. Type Connectable conductor cross-section Insulation Color

55.3220-20 POAG-KBT6-EC/4 4.0 mm² Ø 5.1 mm PA ¹⁾ 20 Ni

55.3225-20 POAG-KBT6-EC/6 6.0 mm² Ø 6.2 mm PA ¹⁾ 20 Ni

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MA564 1) These parts have been tested by TÜV Rheinland. www.staubli.com/electrical Certificate no. R 60116228

16 Medical technology main catalog POAG-HK.../KBT6-EC ization. One end with assembled right-an- with MULTILAM­ made of gold-plated, hard- Highly flexible connecting leads with gled, spring-loaded socket, other end open drawn copper alloy. Various lead cross sec- green-yellow insulation for potential equal- lead. Socket made of nickel-plated brass tions available.

L

Order No. Type Lead cross section Lead lengths Color L [cm]

55.3221- 20 POAG-HK4/KBT6-EC 4.0 mm² PVC ¹⁾ 100 200 300 400 20 Ni max. Ø 5.9 mm

55.3226- 20 POAG-HK6/KBT6-EC 6.0 mm² PVC ¹⁾ 100 200 300 400 20 Ni

POAG-HK.../KBT6-EC/KBT6-EC ization. On both ends with assembled made of gold-plated, hard-drawn copper Highly flexible connecting leads with right-angled, spring-loaded socket. Sockets alloy. Various lead cross sections available. green-yellow insulation for potential equal- made of nickel-plated brass with MULTILAM­

L

Order No. Type Lead cross section Lead lengths Color L [cm]

55.3222- 20 POAG-HK4/KBT6-EC/KBT6-EC 4.0 mm² PVC ¹⁾ 100 200 300 400 20 Ni max. Ø 5.9 mm

55.3227- 20 POAG-HK6/KBT6-EC/KBT6-EC 6.0 mm² PVC ¹⁾ 100 200 300 400 20 Ni

1) These parts have been tested by TÜV Rheinland. Certificate no. R 60116228

Medical technology main catalog 17 MC-POAG-EC/2 MC-POAG-EC6/2 equalization. On both ends with right-an- nickel-plated brass with MULTILAM­ made of Highly flexible connecting leads with gled, spring-loaded sockets with extru- gold-plated, hard-drawn copper alloy. Vari- green-yellow insulation for potential sion-moulded insulation. Sockets made of ous lead cross sections available.

L

Order No. Type Lead cross section Sleeve Lead lengths Color insulation L [cm]

55.3200- 20 MC-POAG-EC/2 4.0 mm² TPE PVC ¹⁾ 100 300 20 Ni

55.3210- 20 MC-POAG-EC6/2 6.0 mm² TPE PVC ¹⁾ 100 300 20 Ni

POAG-KBT6DIN Socket made of nickel-plated brass with Right-angled socket for self-assembly of ­MULTILAM made of gold-plated, hard- connecting leads for potential equalization. drawn copper alloy. Crimp connection.

POAG-WB6DIN T-POAG6 4 mm2 / 6 mm2 max. Ø 5,9 mm

Order No. Type Connectable conductor Outer diameter Insulation Color cross-section

15.0010 POAG-KBT6DIN 4.0 mm² / 6.0 mm² Ø 5.9 mm TPE ¹⁾ 24 Ni

Component parts

15.5004-24 T-POAG6 Insulator 01.0404 POAG-WB6DIN Socket

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

Assembly instructions MA016 1) These parts have been tested by TÜV Rheinland. www.staubli.com/electrical Certificate no. R 60116228

18 Medical technology main catalog POAG-S6/... Ø 6 mm plugs made of nickel-plated brass, to screw into instruments, beds or wall rails for potential equalization. Delivered in four standard lengths, other lengths on request. The assembly material is not supplied!

POAG-S6/15POAG-S6/15POAG-S6/15 POAG-S6/20POAG-S6/20POAG-S6/20

POAG-S6/25POAG-S6/25POAG-S6/25 POAG-S6/35POAG-S6/35POAG-S6/35

Order No. Type Tightening torque

04.0056 POAG-S6/15 max. 3 Nm ¹⁾ Ni

04.0057 POAG-S6/20 max. 3 Nm ¹⁾ Ni

04.0058 POAG-S6/25 max. 3 Nm ¹⁾ Ni

04.0059 POAG-S6/35 max. 3 Nm ¹⁾ Ni

Assembly material

14.5010 FR-POAG-S Color code washer 08.0704 F/M6 Serrated lock washer (DIN 6798) 08.0501 MU0,5D/M6 Nut (DIN 439) 08.0502 MU0,8D/M6 Nut (DIN 934) 08.0601 U/M6 Washer (DIN 125)

1) These parts have been tested by TÜV Rheinland. Certificate no. R 60116228

Medical technology main catalog 19 POAG-ID6 plug POAG-S6/25, nickel-plated according A black colored panel terminal with a to DIN standard. Suitable for mounting in green-yellow colored and a built-in flushtype boxes.

ntageanl m richti e Mo eitung d zu gen E ein . un insa in tz b de Ich s ich unbedin ktes. Im Mo lte m gt l odu ment sol e- Pr ist an d M ie man das Produk t zwar ein bisch evor t ve hrif en , b r- Sc klei sen n, h beinhalte w er geht das t! Ic ert spät dann nde vol er gan we le ab z

se zur korrekten M sen, da die MA wei on u le dan Hin tag t z n e gu MA

minmin 1 1 min 1 maxmax 7 7 Assemblymax 7 instructions MA045 Drilling plan www.staubli.com/electrical

Order No. Type Insulation Color

14.0007 POAG-ID6 POM ¹⁾ 20 Ni

Supplied component parts

14.5007 IS-POAG Insulation housing 14.5005 MUID/M18x1 Ring nut, nickel-plated 08.0502 MU0,8D/M6 2 nuts (DIN 934) 08.0601 U/M6 3 washers 08.0704 FM/6 Serrated lock washer (DIN 6798) 14.5004-20 FR6 Color code washer

Accessories

14.5008 SS6 Socket spanner

MC-POAG-K6FS/VMB3/KBT6DIN/100 Fitted at one end with right-angled female POAG-ID6. Contact parts in nickel-plated Highly flexible green-yellow extension lead plug with spring-loaded ­MULTILAM (type brass, ­MULTILAM of socket in gold-plated with triple socket for potential equalization. POAG-KBT6DIN), other end 3 terminals hard copper alloy.

Order No. Type Lead cross section Lead lengths Color L [cm]

15.2017-100 MC-POAG-K6FS/VMB3/KBT6DIN/100­ 6.0 mm² PVC ¹⁾ 100 20 Ni

1) These parts have been tested by TÜV Rheinland. Certificate no. R 60116228

20 Medical technology main catalog Multistrand wires for medical applications

FLEXI-S/POAG-HK... Typical Application: Potential equalization, Highly flexible, reinforced PVC insulated e.g. in the medical engineering field. stranded wire. Green-yellow insulation. Su- per-fine strand, bright-soft, tightly twisted. Order No. Type Nominal cross section Strand design Weight of cable Conductor diameter Thickness insulation wall Outer diameter Rated voltage Test voltage Rated current * Colors

PVC mm² n × Ø mm kg/km mm mm mm V VAC A 15.2010- 20 FLEXI-S/POAG-HK4 4.0 1036 × 0.07 52 3.0 0.90 4.8 600 2500 42 20 15.2015- 20 FLEXI-S/POAG-HK6 6.0 1548 × 0.07 80 3.8 1.05 5.9 600 2500 54 20

If you are interested in our full range of “Cables and multistrand wires”, please ask for a copy of our main catalog!

Medical technology main catalog 21 Tools

MB2-S SS2-S SS2-M SS4 Steel assembly mandrel and pipe spanner for press-fit and screw-mounting terminals MEB... and MLB...

SS2-S SS4

SS2-M MB2-S

Order No. Type Designation Suitable for terminal types

25.0028 MB2-S Assembly mandrel MEB1,5-R 25.0023 SS2-S Tube spanner MLB1,5-R 25.0026 SS2-M Tube spanner MLB2,0-R, MLB2,0-R 25.0021 SS4 Tube spanner MLB1,5-R, MLB2,0-R, MLB2,0-R

Socket Spanner

Order No. Type

14.5008 SS6

Crimping pliers

Order No. Type

14.5009 POAG-PZ-N

22 Medical technology main catalog Index

Type Page Type Page

FLEXI-S/POAG-HK4 21 MU0,5D/M6 19 FLEXI-S/POAG-HK6 21 MU0,8D/M6 19, 20 F/M6 19 MUID/M18x1 20 FM/6 20 POAG-HK4/KBT6-EC 17 FR6 20 POAG-HK4/KBT6-EC/KBT6-EC 17 FR-POAG-S 19 POAG-HK6/KBT6-EC 17 IS-POAG 20 POAG-HK6/KBT6-EC/KBT6-EC 17 MB2-S 22 POAG-ID6 20 MC-POAG-EC/2 18 POAG-KBT6DIN 18 MC-POAG-EC6/2 18 POAG-KBT6-EC/4 16 MC-POAG-K6FS/VMB3/KBT6DIN/100 20 POAG-KBT6-EC/6 16 MEB1,5-R 9 POAG-PZ-N 22 MEB2,0-L 11 POAG-S6/15 19 MEB2,0-R 11 POAG-S6/20 19 MLA2 13 POAG-S6/25 19 MLA2-S 13 POAG-S6/35 19 MLB1,5-R 9 POAG-WB6DIN 18 MLB2,0-L 12 SS2-M 22 MLB2,0-R 12 SS2-S 22 MLK2,0-LS/P 14 SS4 22 MS155-B 8 SS6 22 MS205-S 10 T-POAG6 18 MS255-B 10 U/M6 19, 20 MS1525-B 8 MS1525-S 8 MS2025-S 10

Medical technology main catalog 23 ME Med Main 11014109-en C 02.2021 Med ME

Stäubli Units Representatives / Agents

Global presence of the Stäubli Group www.staubli.com

Staubli is a trademark of Stäubli International AG, registered in Switzerland and other countries. We reserve the right to modify product specifi cations without prior notice. © Stäubli 2021. Photo credits: Stäubli, Shutterstock.com