Unraveling the Levee Failure in New Orleans During Hurricane Katrina
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
JEFFERSON PARISH COUNCIL MEETING Wednesday, May 16, 2018 1221 ELMWOOD PARK BOULEVARD JEFFERSON, LOUISIANA
JEFFERSON PARISH COUNCIL MEETING Wednesday, May 16, 2018 1221 ELMWOOD PARK BOULEVARD JEFFERSON, LOUISIANA SPECIAL PRESENTATIONS BY: BUSINESS MEETING BEGINS AT 10:00 AM MEETING CALLED TO ORDER INVOCATION AND/OR PLEDGE OF ALLEGIANCE ROLL CALL - COUNCIL MEMBERS ROLL CALL - PARISH PRESIDENT AND DIRECTORS OF DEPARTMENTS PARISH PRESIDENT TO ADDRESS COUNCIL PERSONS WISHING TO APPEAR BEFORE THE COUNCIL REGARDING A RESOLUTION(S) ON AGENDA/ADDENDUM AGENDA ORDINANCES TO BE DEFERRED 1. SUMMARY NO. 24759 - repealing Chapter 2, Article VI, Sections 2-811 through 2-818 of the Code and enacting Chapter 2, Article VI, Sections 2-811 through 2-818 of the Jefferson Parish Code of Ordinances relative to the Transportation Advisory Board. (Parishwide) (Deferred from 4/25/18)(Proposed ordinance was not pre-filed in compliance with Sec.2-34.2 of the Jefferson Parish Code of Ordinances) 2. SUMMARY NO. 24799 - amending Chapter 2, Article II, Division 2 of the Code relative to the recording and broadcast of meetings of the Jefferson Parish Council. (Parishwide) (Deferred from 4/25/18) (Proposed ordinance was not pre-filed in compliance with Sec. 2-34.2 of the Jefferson Parish Code of Ordinances) 3. SUMMARY NO. 24894 - amending the Code to reduce and/or eliminate redundancies and fees with respect to requirements for emergency medical technicians. (Parishwide) (Deferred from 4/25/18) (Proposed ordinance was not pre-filed in compliance with Sec.2-34.2 of the Jefferson Parish Code of Ordinances) 4. SUMMARY NO. 24961 - amending Ordinance No. 18226, as amended, to amend Rule V Pay Plan of the Personnel Rules of the East Bank Consolidated Fire Protection District to add the position of Deputy Fire Chief. -
By CWO Franz Karnuth Marine Safety Office-St. Louis
Number 35 November/December 2005 Edition INSIDE THIS ISSUE CLOSE CALL ON THE MISS. RIVER GCMA ATTENDS OCT. TSAC MEETING CAPT. DADY’S REMARKS AT TSAC BREAKAWAY BARGE FOLLOW UP HURRICANES DESTROY 109 OIL PLATFORMS GIVING AWAY MARINER JOBS LICENSING LICENSE REQUIREMENTS FOR TOWING VESSELS CHANGES AHEAD AT NATIONAL MARITIME CENTER “OPERATORS” BECOME “MASTERS” GCMA CRITICIZES MERPAC NEW GCMA RESEARCH REPORTS SECURITY CODE HURTS MARINERS BROWN LIST (UNCHANGED THEIR LEVEES – OUR LEVEES By CWO Franz Karnuth Marine Safety Office-St. Louis [Source: The Waterways Journal, Oct. 3, 2005] [Note: Underlining for emphasis is ours.] Four hours into the morning watch, the sky is overcast, and the outside air tem- perature is roughly 40 degrees. You're manning the sticks of a small towboat on the cold winter waters of the Mississippi River. The boat's two-man relief crew is resting in their bunks. You've picked up one loaded rock barge, topped around, and are backing in to place the barge's port side against a mooring barge. Your sole deckhand rounds the stern port side of your loaded barge, goes behind some cargo covers to secure a line to the mooring barge and begins to put a couple of figure eights on the barge's port stern quarter kevel. Suddenly, out of the comer of your eye you catch something happening with your deckhand a hand, a spray of water. You're not sure so you move to the port side of the wheelhouse to get a better look. Over the radio you hear a call for help. -
Permanent Protection System Opinion of Probable Cost Volume I Options 1, 2, and 2A Report
May 2010 Louisiana Coastal Protection and Restoration Authority Permanent Protection System Opinion of Probable Cost Volume I Options 1, 2, and 2a Report Prepared for Sewerage & Water Board of New Orleans in partnership with the Southeast Louisiana Flood Protection Authority- East, Jefferson Parish Department of Public Works, and the Louisiana Coastal Protection and Restoration Authority Photo courtesy of USACE Graphics Water Prepared for: Sewerage & Water Board Prepared by: of New Orleans AECOM New Orleans, LA New Orleans, Louisiana Color 60149879.0005 May 7, 2010 Permanent Protection System Opinion of Probable Cost Options 1, 2, and 2a AECOM Water i Contents Executive Summary ............................................................................................................. ES-1 1.0 Option 1 – Construction of New Permanent Gated Pump Stations at the Mouths of the 17th Street, Orleans Avenue, and London Avenue Canals ................................. 1-1 1.1 Option 1 - Basis of Opinion of Probable Cost ..................................................................... 1-3 1.2 Summary of Findings for 17th Street Canal – Option 1...................................................... 1-4 1.2.1 Mechanical and Electrical .....................................................................................1-6 1.2.2 Geotechnical ......................................................................................................... 1-9 1.2.3 Real Estate ..........................................................................................................1-10 -
New Orleans and Hurricane Katrina. III: the 17Th Street Drainage Canal
New Orleans and Hurricane Katrina. III: The 17th Street Drainage Canal R. B. Seed, M.ASCE1; R. G. Bea, F.ASCE2; A. Athanasopoulos-Zekkos, S.M.ASCE3; G. P. Boutwell, F.ASCE4; J. D. Bray, F.ASCE5; C. Cheung, M.ASCE6; D. Cobos-Roa7; L. F. Harder Jr., M.ASCE8; R. E. S. Moss, M.ASCE9; J. M. Pestana, M.ASCE10; M. F. Riemer, M.ASCE11; J. D. Rogers, M.ASCE12; R. Storesund, M.ASCE13; X. Vera-Grunauer, M.ASCE14; and J. Wartman, M.ASCE15 Abstract: The failure of the levee and floodwall section on the east bank of the 17th Street drainage canal was one of the most catastrophic breaches that occurred during Hurricane Katrina. It produced a breach that rapidly scoured a flow pathway below sea level, so that after the storm surge had largely subsided, floodwaters still continued to stream in through this breach for the next two and a half days. This particular failure contributed massively to the overall flooding of the Metropolitan Orleans East Bank protected basin. Slightly more than half of the loss of life, and a similar fraction of the overall damages, occurred in this heavily populated basin. There are a number of important geotechnical and geoforensic lessons associated with this failure. Accordingly, this paper is dedicated solely to investigating this single failure. Geological and geotechnical details, such as a thin layer of sensitive clay that was laid down by a previous hurricane, proper strength characterization of soils at and beyond the toe of the levee, and recognition of a water-filled gap on the inboard side of the sheet pile cutoff wall are judged to be among the most critical factors in understanding this failure. -
Hurricane Katrina External Review Panel Christine F
THE NEW ORLEANS HURRICANE PROTECTION SYSTEM: What Went Wrong and Why A Report by the American Society of Civil Engineers Hurricane Katrina External Review Panel Christine F. Andersen, P.E., M.ASCE Jurjen A. Battjes, Ph.D. David E. Daniel, Ph.D., P.E., M.ASCE (Chair) Billy Edge, Ph.D., P.E., F.ASCE William Espey, Jr., Ph.D., P.E., M.ASCE, D.WRE Robert B. Gilbert , Ph.D., P.E., M.ASCE Thomas L. Jackson, P.E., F.ASCE, D.WRE David Kennedy, P.E., F.ASCE Dennis S. Mileti, Ph.D. James K. Mitchell, Sc.D., P.E., Hon.M.ASCE Peter Nicholson, Ph.D., P.E., F.ASCE Clifford A. Pugh, P.E., M.ASCE George Tamaro, Jr., P.E., Hon.M.ASCE Robert Traver, Ph.D., P.E., M.ASCE, D.WRE ASCE Staff: Joan Buhrman Charles V. Dinges IV, Aff.M.ASCE John E. Durrant, P.E., M.ASCE Jane Howell Lawrence H. Roth, P.E., G.E., F.ASCE Library of Congress Cataloging-in-Publication Data The New Orleans hurricane protection system : what went wrong and why : a report / by the American Society of Civil Engineers Hurricane Katrina External Review Panel. p. cm. ISBN-13: 978-0-7844-0893-3 ISBN-10: 0-7844-0893-9 1. Hurricane Katrina, 2005. 2. Building, Stormproof. 3. Hurricane protection. I. American Society of Civil Engineers. Hurricane Katrina External Review Panel. TH1096.N49 2007 627’.40976335--dc22 2006031634 Published by American Society of Civil Engineers 1801 Alexander Bell Drive Reston, Virginia 20191 www.pubs.asce.org Any statements expressed in these materials are those of the individual authors and do not necessarily represent the views of ASCE, which takes no responsibility for any statement made herein. -
Engineering Geologic Characterization of Levee Failures
ENGINEERINGENGINEERING GEOLOGICGEOLOGIC CHARACTERIZATIONCHARACTERIZATION OFOF LEVEELEVEE FAILURESFAILURES ININ NEWNEW ORLEANSORLEANS DURINGDURING HURRICANEHURRICANE KATRINAKATRINA J. David Rogers, Ph.D., P.E., R.G. Member, National Science Foundation Independent Levee Investigation Team and Karl F. Hasselmann Chair in Geological Engineering University of Missouri-Rolla 2006 Annual Meeting Association of Environmental and Engineering Geologists Boston, Massachusetts November 1, 2006 PartPart 11 GEOLOGICGEOLOGIC SETTINGSETTING OFOF NEWNEW ORLEANSORLEANS • Pleistocene geologic map of the New Orleans area. The yellow stippled bands are the principal distributory channels of the lower Mississippi River, with the present channel shown in light blue. The Pine Island Beach Trend is shown in the ochre dotted pattern. Depth contours on the upper Pleistocene age horizons are also shown. • Contours of the entrenched surface of the Wisconsin glacial age deposits underlying modern New Orleans. • Note the well developed channel leading southward, towards what used to be the oceanic shoreline. This channel reaches a maximum depth of 150 feet below sea level. • Block diagram of the geology underlying New Orleans. The principal feature dividing New Orleans is the Metairie distributary channel, shown here, which extends to a depth of 50 feet below MGL and separates geologic regimes on either side. Note the underlying faults, beneath Lake Pontchartrain. • Block diagram illustrating relationships between subaerial and subaqueous deltaic environments in relation to a single distributary lobe. • The Lakeview and Gentilly neighborhoods of New Orleans are underlain by interdistributary sediments, overlain by peaty soils lain down by fresh water marshes and cypress swamps. • Typical cross section through the sandy bank levees of the Mississippi River, illustrating how the river’s main channel lies above the surrounding flood plain, which were poorly drained swamp lands prior to reclamation. -
N:\Wpdocs\Cases\05-4182 in Re Katrina Canal Breaches Lit
Case 2:11-cv-02350-ILRL-JCW Document 100 Filed 12/06/12 Page 1 of 21 UNITED STATES DISTRICT COURT EASTERN DISTRICT OF LOUISIANA PARISH OF ST. BERNARD CIVIL ACTION THROUGH THE ST. BERNARD PARISH GOVERNMENT VERSUS NO. 11-2350 LAFARGE NORTH AMERICA, INC., ET AL. SECTION “K”(2) ORDER Before the Court are the following: (1) Lafarge North America Inc.’s Motion for Summary Judgment (Doc. 67); (2) Fed. R. Civ. P. 56(d) Motion to Stay or Continue Lafarge North America, Inc.’s Motion for Summary Judgment (Doc. 74) filed by the Parish of St. Bernard; and (3) Motion for Leave to Supplement the Record (Doc. 98) filed by the Parish of St. Bernard. These motions are pending in the above-referenced matter brought by the Parish of St. Bernard (“St. Bernard”) against Lafarge North American, Inc. ( “Lafarge”). St. Bernard contends that Lafarge’s allegedly inappropriate handling of Barge ING 4727 ( “the Barge”) was a substantial cause of the north and south breaches of the eastern flood walls along the Inner-Harbor Navigation Canal (“IHNC”) which resulted in the inundation of parts of St. Bernard with the passage of Hurricane Katrina over the area. Based on the reasons that follow, the Court finds that Lafarge’s Motion for Summary Judgment has merit and that there is no justifiable reason to delay the entry of summary judgment in its favor. Case 2:11-cv-02350-ILRL-JCW Document 100 Filed 12/06/12 Page 2 of 21 Procedural Background The issue of whether the Barge caused the breaches of the floodwall on the eastern bank of the IHNC has been pending in this Court for more than seven years. -
Wednesday, April 6, 2016 1221 ELMWOOD PARK BOULEVARD JEFFERSON, LOUISIANA JEFFERSON PARISH COUNCIL MEETING SPECIAL PRESENTATIONS
JEFFERSON PARISH COUNCIL MEETING Wednesday, April 6, 2016 1221 ELMWOOD PARK BOULEVARD JEFFERSON, LOUISIANA SPECIAL PRESENTATIONS BY: BUSINESS MEETING BEGINS AT 10:00 AM MEETING CALLED TO ORDER INVOCATION AND/OR PLEDGE OF ALLEGIANCE ROLL CALL - COUNCIL MEMBERS ROLL CALL - PARISH PRESIDENT AND DIRECTORS OF DEPARTMENTS PARISH PRESIDENT TO ADDRESS COUNCIL READING OF CAMPAIGN FINANCE CONTRIBUTIONS PERSONS WISHING TO APPEAR BEFORE THE COUNCIL REGARDING A RESOLUTION(S) ON AGENDA/ADDENDUM AGENDA ORDINANCES TO BE DEFERRED 1. SUMMARY NO. 24373 - amending Section 17-20 of the Code regarding support of the prison medical unit. (Parishwide) (Proposed ordinance was not pre-filed in compliance with Sec. 2-34.2 of the Jefferson Parish Code of Ordinances) (Deferred from 3/2/16) 2. SUMMARY NO. 24447 - amending the Code to establish requirements with regard to the submission of invoices from sub-consultants to the Parish and the timely payment of sub-consultants by primary consultants under contract with the Parish or with any of the Parish’s departments, agencies or districts. (Parishwide) (Proposed ordinance was not pre-filed in compliance with Sec.2-34.2 of the Jefferson Parish Code of Ordinances) 3. SUMMARY NO. 24473 - amending 2016 Operating Budget. (Parishwide) (Proposed ordinance was not pre-filed in compliance with Sec. 2-34.2 of the Jefferson Parish Code of Ordinances) 4. SUMMARY NO. 24474 - amending 2016 Capital Budget. (Parishwide) (Proposed ordinance was not pre-filed in compliance with Sec. 2-34.2 of the Jefferson Parish Code of Ordinances) 5. SUMMARY NO. 24475 - amending 2016 Operating Budget. (Parishwide) (Proposed ordinance was not pre-filed in compliance with Sec. -
Interaction Between the US Army Corps of Engineers and the Orleans Levee Board Preceding the Drainage Canal Wall Failures and Ca
Water Policy 17 (2015) 707–723 Interaction between the US Army Corps of Engineers and the Orleans Levee Board preceding the drainage canal wall failures and catastrophic flooding of New Orleans in 2005 J. David Rogersa, G. Paul Kempb, H. J. Bosworth Jrc and Raymond B. Seedd a157 McNutt Hall, Missouri University of Science and Technology, Rolla, MO 65409, USA b633 Magnolia Wood Avenue, Baton Rouge, LA 70808, USA cCorresponding author. 1527 S. Carrollton Avenue, New Orleans, LA 70118, USA. E-mail: [email protected] d760 Davis Hall, University of California, Berkeley, CA 94720, USA Abstract The authors hope to correct any premature conclusions about the role of the pre-Katrina Orleans Levee Board (OLB) in the failure of the outfall drainage canals in New Orleans during the 2005 hurricane – conclusions that appear to have been based on inaccurate information and/or assumptions. With regard to the 17th Street and London Avenue Canals, the authors have not uncovered any information that would suggest that the OLB behaved irresponsibly in its duties. What is evident from the project record is that the Army Corps of Engineers rec- ommended raising the canal floodwalls for the 17th Street Canal, but recommended gated structures at the mouths of the Orleans and London Avenue Canals because the latter plan was less expensive. The OLB convinced Congress to pass legislation that required the Corps to raise the floodwalls for all three canals. Furthermore, the Corps, in a separate attempt to limit project costs, initiated a sheet pile load test (E-99 Study), but misinterpreted the results and wrongly concluded that sheet piles needed to be driven to depths of only 17 feet (1 foot ¼ 0.3048 meters) instead of between 31 and 46 feet. -
Jefferson Parish Library
JEFFERSON PARISH 2015 MULTIJURISDICTIONAL HAZARD MITIGATION PLAN UPDATE MARCH 2015 Table of Contents Section 1 Executive Summary 6 1.1 Organization of the Plan 7 1.2 Background 7 1.3 Hazards and Risks 8 1.3.1 Hazards 8 1.3.2 Risks 9 1.4 Summary of Goals, Objectives, Strategies and Actions 9 1.4.1 Hazard Mitigation Goals 9 1.4.2 Hazard Mitigation Objectives 10 1.4.3 Hazard Mitigation Strategies 10 1.4.4 Action Items 11 1.5 The Planning Process 11 1.6 Approval and Adoption Process 12 1.7 Implementation Process 12 1.8 Monitoring and Updating Processes 12 Section 2 Background 13 2.1 Introduction 13 2.1.1 Scope of the Plan 13 2.2 Organization, Objectives and Mission 14 2.3 Background Information 15 2.3.1 Geography 15 2.3.2 Parish History 18 2.3.3 Climate 19 2.3.4 Transportation 19 2.3.5 Community Assets 19 2.3.6 Population and Growth 21 2.4 The Louisiana State Hazard Mitigation Plan 24 Section 3 Planning Process 25 3.1 Interim Final Rule Requirements 25 3.2 Federal Mitigation Planning Requirements 26 3.3 Description of the Planning Process 27 3.3.1 How the Plan was Prepared and Updated 27 3.3.2 Step 1 – Organize Resources 28 3.3.3 Step 2 – Assess Risks 31 3.3.4 Step 3 – Identify and Scope Potential Projects 31 3.3.5 Step 4 – Develop the Mitigation Plan 32 2 3.3.6 Step 5 – Implement Plan and Monitor Progress 32 3.4 How the Public and Jurisdictions were Involved 32 3.5 Other Local Planning Mechanisms 33 3.6 Review/Incorporation of Plans, Studies, Reports, and 34 other information Section 4 Hazard Identification, Ranking, and Risk Assessments -
Tidally-Influenced New Orleans Canal Network Benefits from Accurate Water Level Data Aqua TROLL® 200 Instruments Dynamically Compensate for Changing Salinity Values
Innovations in Water Monitoring Application Note Tidally-Influenced New Orleans Canal Network Benefits from Accurate Water Level Data Aqua TROLL® 200 Instruments dynamically compensate for changing salinity values Application The Southern Louisiana Hurricane Protection System includes a network of levees, floodwalls, floodgates, and pumping stations in New Orleans, Louisiana. This network includes monitoring equipment designed to improve management of water levels throughout the system. Water level monitoring helps synchronize pumping and assures that all elements of the water level control system are within proper ranges. Water level monitoring is also conducted around Lake Pontchartrain and at locations upstream and downstream of locks. In addition, groundwater levels are checked throughout the district to scrutinize levee integrity and condition. Both fresh water and saltwater influence water level changes in New Orleans. In areas where salinity values vary due to mixing, rainfall, or tides, water level measurements must be adjusted by compensating for changes in water density due to George Brown of the USACE New Orleans District changes in salinity. Water Management Office works with an In-Situ RuggedReader® Handheld PC and Aqua TROLL 200 Continuous monitoring improves canal Instrument at a pumping station on 17th Street Canal, management constructed after Hurricane Katrina. The gates behind him were included in the new structure to control water Since Hurricane Katrina pounded the Gulf Coast in surge into and out of the canal. The USACE has recently August 2005, the USACE has fortified New Orleans city deployed Aqua TROLL 200 units to profile key water canals with control gates and pumping stations—and parameters along waterways in the New Orleans District. -
The Hurricane Katrina Litigation Against the Corps of Engineers: Is Denial of Geology and Climate Change the Way to Save New Orleans?
University of Arkansas at Little Rock Law Review Volume 40 Issue 4 The Ben J. Altheimer Symposium: The Law and Unnatural Disasters: Legal Adaptations Article 8 to Climate Change 2018 The Hurricane Katrina Litigation Against the Corps of Engineers: Is Denial of Geology and Climate Change the Way to Save New Orleans? Edward P. Richards III Follow this and additional works at: https://lawrepository.ualr.edu/lawreview Part of the Environmental Law Commons Recommended Citation Edward P. Richards III, The Hurricane Katrina Litigation Against the Corps of Engineers: Is Denial of Geology and Climate Change the Way to Save New Orleans?, 40 U. ARK. LITTLE ROCK L. REV. 695 (2018). Available at: https://lawrepository.ualr.edu/lawreview/vol40/iss4/8 This Article is brought to you for free and open access by Bowen Law Repository: Scholarship & Archives. It has been accepted for inclusion in University of Arkansas at Little Rock Law Review by an authorized editor of Bowen Law Repository: Scholarship & Archives. For more information, please contact [email protected]. THE HURRICANE KATRINA LITIGATION AGAINST THE CORPS OF ENGINEERS: IS DENIAL OF GEOLOGY AND CLIMATE CHANGE THE WAY TO SAVE NEW ORLEANS? Edward P. Richards, III* I. INTRODUCTION The movie Rashomon presents the story of an event from the perspective of four storytellers. Depending on the point of view, the event could be a murder and rape or a battle of honor over a woman.1 Legal scholars have made much of the Rashomon Effect as an example of the ambiguity of truth and the effect of a person’s involvement in an event on the person’s view of the event.2 The story of Hurricane Katrina echoes Rashomon but includes many more unreliable narrators.