Ophthalmic Diagnostics Catalog (Pdf)
Total Page:16
File Type:pdf, Size:1020Kb
REFRACTION • LENSMETERS • RETINAL CAMERA • VISUAL FIELD ANALYZER • SLIT LAMPS • ACUITY CHARTS • EXAM LANES & FURNITURE PROUD DISTRIBUTOR OF WWW.COBURNTECHNOLOGIES.COM AUTOREFRACTOR/KERATOMETER HRK-9000A TFBUT Measurement and Meibography Touch and Tilting 7” Color Display Wireless Communication Conditions of tear film and dry eye can be Wide color TFT LCD supports high-resolution Wireless Communication via Wi-Fi allows collected by TFBUT (Tear Film Break-Up Time) images and real-time image processing to perfect data transmission with HDR-9000 Digital and are readable for thorough understanding of realize after image-less image quality. Moreover, Refractor and HLM-9000 Auto Lensmeter visual acuity. Degeneration of meibomian gland swiveling and tilting touch display is readable regardless of working environment. Classic can be also monitored with enough light source from any direction for smooth communication communication via RS-232 cable is available for and image enhancement function. between examiners and examinees. data transmission with previous models. Subjective VA Test Auto Tracking More Accurate Data Comparison between subjective and objective Cutting edge auto sensor and 3 dimensional Accuracy of KER data is improved by setting VA tests yields more reliable and accurate data. movement mechanism allow you to track and optimal zone diameter on measuring spot and Subjective VA test is useful in deciding the measure the focus of an eye automatically and also REF data by standardization of quantity of necessity of progressive lenses because it checks helps complete measurement perfectly, even light of fogging chart and fogging lens position visual acuity based on patients’ responses. with inexperienced users. along with complete block of accommodation. Contrast Sensitivity and Glare Test Efficient Contact Lens Prescription Contact Lens Fitting Assistance Guide Highly reliable night visual acuity is examinable Image capture and contrast regulation are The world’s first contact lens fitting function in with low contrast sensitivity test and glare test possible. HRK-9000A gives you the best On-K an auto ref/keratometer enables you to see which perfectly reproduces halo effect. Progress fitting guide based on the base curve and KER fluorescein liquid with blue illumination. after refractive or cataract surgery can be value. monitored effectively. Color View Mode Peripheral Keratometry Measurement Full color CCD camera and white LED light Micro Lens Array Continuous measurement on periphery of cornea source in auto ref/keratometer enables you to Huvitz’s own developed Micro Lens Array creates a at 90° both vertically and horizontally from center see eyes and contact lens fitting status, which number of separated focal spots, of which the pattern of cornea produces curvature and eccentricity was previously only possible with slit lamps. provides valuable information of patients’ ocular systems. values of all points and allows best fitting of contact lenses. Iris and Pupil Diameter Measurement Image capturing function supports highly IOL Mode accurate exam by measurement of iris and pupil Extra measurement mode is available for IOL diameter with diameter from 2mm to 14mm. power or visual acuity after cataract surgery. 2 AUTOREFRACTOR/KERATOMETER HRK-8000A AUTO REF-KERATOMETER Contact Lens Fitting Assistance Guide More Data on Aberration Measurement Micro Lens Array The world’s first contact lens fitting function High order aberration data such as Coma, Trefoil, Huvitz’s own developed Micro Lens Array in an auto ref-keratometer enables you to see Spherical Aberration, Secondary Astigmatism, creates a number of separated focal spots, fluorescein liquid with blue illumination. The and Tetrafoil, which was only available in of which the pattern provides valuable HRK-8000A also analyzes and simulates the wavefront aberrometers, is now available. information of the customer’s ocular system. lens fitting status with automatic calculation and recommendation. HRK-8000A gives you the best High Order Aberration Map Touch & Tilting Color Display Screen On-K fitting guide based on the base curve and Besides the conventional data such as spherical, High brightness and contrast VGA 7” wide KER value measured. cylinder and axis, the high order aberration data color TFT LCD screen provides with high is displayed in a graphical Zernike refraction map resolution video images. Smooth and free Customized Lens Manufacturing for a better understanding of patient’s eyes and tilting function also offers you a comfortable High order aberration and Zernike map data superior clinical decision making. and clear view at any angle. output function allow premium custom spectacle or contact lens manufacturers to improve vision Color View Mode Auto Tracking accuracy and power. The Full Color CCD camera and white LED light Cutting edge auto sensor and 3-dimensional source in the auto ref/keratometer enables you movement mechanism allow you to track and Ultra High Precision KER Data to see eyes and contact lens fitting status which measure the focus of an eye automatically Mire ring and LED sources enable highly reliable was previously only possible with slit lamps. and helps complete measurement perfectly, keratometry data of the corneal base curve to be even with inexperienced users. obtained. Peripheral Keratometry Measurement Comfortable One Touch Lock Optimized Optical System The upper moving stage can be locked easily Wavefront Technology measures the wavefront with one touch of a button. of light reflected from the retina and the refractive power with various sensors divided by sectors and analyzes them with extreme precision. 3 AUTOREFRACTOR/KERATOMETER HRK-1 Smart Assembly Easy One-Touch Lock Familiar User Friendly Interface Moving Control Technology For convenience, the upper moving stage can be Featuring an icon-based intuitive operating The invisible technology behind Huvitz’s REF easily locked down. system, the interface is simple for all users. optical system can be seen in the accuracy and stability of the measurement results. High-Speed Printer and Simple Up & Down Auto Tracking Considering the refractive error of the patient, Convenient Paper Change The auto tracking feature automatically tracks the measurement ring is projected on the retina, Ability to print 10 measurement results quickly & the eye of the patient making it easier to measure and is adjusted automatically by Smart Assembly quietly in less than 3 seconds with an easy and by manipulating the joystick back and forth Moving to secure a stable signal. HRK-1 uses this simple printer paper changing function. without having to rotate the joystick. moving optic mechanism to scan more of the cornea’s surface area resulting in a more accurate Clear Retro-Illumination Mode Quick Virtual Aiming Dot Function measurement of reflected light. You can observe the eye health & condition, The aiming dot quickly guides you to easily such as lens opacity or corneal damage. find the patient’s visual apex from any position Touch-Enabled 7-inch Color Display SPH, CYL and AXIS measurement data required for fast alignment. Reliable refractive power Adopting a wide color TFT LCD that provides high for eyeglass and contact lens prescriptions are REF data is then automatically obtained. quality imaging with real-time processing chip made at the same time. design. It also has a buttonless touch screen that Secure Delete Confirm Dialog is as familiar and convenient as a smartphone. Contact Lens Fitting Assistance Guide Delete Confirm Dialog function prevents the The magnified optical magnification allows you Image processing, using a fluorescent solution data from being deleted immediately after to observe and measure the eye of the subject in and yellow filter, automatically determines the measurement, to aid in further analysis. detail with a sharper and larger size. fitting state. Friendly External Monitor Display Convenience for Immediate Color View Mode By connecting the measurement results to an Prescribing Contact Lenses Full color camera and white LED light is used external monitor, you can easily and accurately Adjusting and capturing the contrast of the image for color display, overall condition monitoring, communicate the diagnostic results. being observed, HRK-1 automatically calculates contact lens fitting and prescription. and displays the base curve value of the lens by Lensmeter Printer Features the On-K fitting used when prescribing the contact Intuitive Iris, Measurement of Pupil Size It can directly connect to our automatic lens from measured KERATO Data (RGP lens only). With the image capture function, iris and pupil lensmeter (HLM-1) using optional Y-cable for diameter can be measured up to 14mm, and REF printing HLM-1’s measurement result. measurement with a pupil diameter as small as 2mm. 4 AUTOREFRACTOR/KERATOMETER SPECIFICATIONS Model HRK-9000A HRK-8000A HRK-1 K/R Mode Continuous Keratometry & Refractometry REF Mode Refractometry KER Mode Keratometry Color View Mode Color View & Contact Lens Fitting Assistance (White & Blue LED Light) Meibography Mode Special Mode for Observing Meibomian Gland N/A N/A TFBUT Mode Special Mode for Measuring TFBUT (Tear Film Break-Up Time) N/A N/A MEASUREMENT MODE MEASUREMENT CLBC Mode Contact Lens Base Curve Measurement: 0~180˚ (Increments : 1˚) N/A KER P Mode Peripheral Keratometry N/A Vertex Distance (VD) 0.0, 12.0, 13.5, 13.75, 15.0 0.0, 12.0, 13.5, 15.0 0.0, 12.0, 13.75, 15.0 Sphere (SPH) -30.00~+25.00D (VD=12mm) (Increments : 0.01, 0.12, 0.25D)