Conventional Water Treatment Processes Part 1

Total Page:16

File Type:pdf, Size:1020Kb

Conventional Water Treatment Processes Part 1 How Water Works ILLUSTRATED PROCESSES, EQUIPMENT, AND TECHNOLOGY Conventional Water Treatment Processes: Traditional Methods Stand the Test of Time or many years, the combined processes of mixing, flocculation, sedimentation, filtration, and chlorine disinfection shown here have formed traditional water treatment Fplant design. This approach, known as conventional treatment, effectively removes practically any range of raw water turbidity, along with harmful bacteria, including E. coli, viruses, and protozoans, such as Giardia lamblia and amoebas. Next month, How Water Works will begin looking at these conventional treatment processes in detail. 1. Raw water basins slow the water’s velocity after it passes through the intake structure, allowing heavy sediment and grit to settle to the bottom of the basins before the water enters the 2 treatment plant. 6 2. Chemical coagulants are added to react with the remaining small particles in the water to form particles large enough to 9 settle out. Rapid mixing distributes the 8 coagulant evenly throughout the water. 3 7 3. Flocculation basins gently mix the water with large submerged paddles so smaller particles collide to form large particles called “floc.” 4. Floc settles by gravity to the bottom of a sedimentation basin. Clean water spills over to the filters. 4 5. Filtration removes any remaining particles. The force of gravity moves the water through filter media—primarily sand, anthracite coal, granular activated carbon, 5 garnet sand, or some combination of these materials. CHOLS NEERS I Ni 6. Chlorine is added for disinfection. A chlorinator meters chlorine gas from a NG E chlorine cylinder or other container and then delivers the set dosage. AROLLO AROLLO C 1 LTON W 7. Finished water basins ensure contact time is allotted for adequate & ATES/FREESE I NO NGS: NGS: disinfection. K wi SSOC A RA RON D 8. A clearwell stores water before the water enters the : ON NG NG I I distribution system. LUMMER P NEER I NG LAN LLUSTRAT I 9. Pumps send clean, safe water throughout the E A community. Some illustration elements exaggerated for emphasis. 18 Opflow October 2006 www.awwa.org/communications/opflow www.awwa.org/communications/opflow October 2006 Opflow 19.
Recommended publications
  • Drinking Water Treatment Systems
    Drinking Water Facts….. Drinking Water Treatment Systems By: Barbara Daniels and Nancy Mesner Revised December 2010 If your home water comes from a public water supply, it has been tested and meets EPA standards for drinking water. If you use a private well, however, you are responsible for assuring that the water is safe to drink. This means that you should periodically have your water tested, make sure your well is in proper condition without faulty well caps or seals, and identify and remove potential sources of con- tamination to your well such as leaking septic systems or surface contamination. With a private well, you are also responsible for any treatment your water may need if it contains harm- ful pollutants or contaminants that affect the taste, odor, corrosiveness or hardness of the water. This fact sheet discusses different types of water treatment systems available to homeowners. Addressing the source of the problem is often less costly in the long run than installing and maintaining a water system. For more information on identifying pollutant sources, problems with your well, or help in testing your well water, see the references at the end of this fact sheet. There are many types of water treatment systems available. No one type of treatment can address every water quality problem, so make sure you purchase the type of equipment that can effectively treat your particular water quality issue. The table below can help direct you to the right solution for your prob- lem. Drinking Water Facts….. What type of water treatment is needed? The table below lists common water contamination problems.
    [Show full text]
  • Total Organic Carbon (TOC) Guidance Manual
    September 2002 RG-379 (Revised) Total Organic Carbon (TOC) Guidance Manual Water Supply Division printed on recycled paper TEXAS COMMISSION ON ENVIRONMENTAL QUALITY Total Organic Carbon (TOC) Guidance Manual Prepared by Water Supply Division RG-379 (Revised) September 2002 Robert J. Huston, Chairman R. B. “Ralph” Marquez, Commissioner Kathleen Hartnett White, Commissioner Jeffrey A. Saitas, Executive Director Authorization to use or reproduce any original material contained in this publication—that is, not obtained from other sources—is freely granted. The commission would appreciate acknowledgment. Copies of this publication are available for public use through the Texas State Library, other state depository libraries, and the TCEQ Library, in compli- ance with state depository law. For more information on TCEQ publications call 512/239-0028 or visit our Web site at: www.tceq.state.tx.us/publications Published and distributed by the Texas Commission on Environmental Quality PO Box 13087 Austin TX 78711-3087 The Texas Commission on Environmental Quality was formerly called the Texas Natural Resource Conservation Commission. The TCEQ is an equal opportunity/affirmative action employer. The agency does not allow discrimination on the basis of race, color, religion, national origin, sex, disability, age, sexual orientation or veteran status. In compliance with the Americans with Disabilities Act, this document may be requested in alternate formats by contacting the TCEQ at 512/239-0028, Fax 239-4488, or 1-800-RELAY-TX (TDD), or by writing
    [Show full text]
  • 19. Water Treatment Plants. the Introduction (Chapter 1) for These
    Chapter 4 – Specifications Designs 19. Water Treatment Plants 19. Water Treatment Plants. The Introduction (Chapter 1) for these design data collection guidelines contains additional information concerning: preparing a design data collection request, design data collection requirements, and coordinating the design data collection and submittal. The following is a list of possible data required for specifications design of water treatment facilities. The size and complexity of the process system and structures should govern the amount and detail of the design data required. A. General Map Showing: (1) A key map locating the general map area within the State. (2) The plant site and other applicable construction areas. (3) Existing towns, highways, roads, railroads, public utilities (electric power, telephone lines, pipelines, etc.), streams, stream-gauging stations, canals, drainage channels. (4) Existing or potential areas or features having a bearing on the design, construction, operation, or management of the project feature such as: recreation areas; fish and wildlife areas; building areas; and areas of archeological, historical, and mining or paleontological interest. The locations of these features should bear the parenthetical reference to the agency most concerned: for example Reclamation. (5) County lines, township lines, range lines, and section lines. (6) Locations of construction access roads, permanent roads, and sites for required construction facilities. (7) Sources of natural construction materials and disposal areas for waste material, including the extent of mitigation required. (a) Location of disposal areas for debris, sediment, sludge, and spent chemicals from cleaning or storage solutions. (8) Water sources to be treated such as surface water or underground water. (9) Location of potential waste areas (i.e., channels).
    [Show full text]
  • Circle Reverse Osmosis System
    CIRCLE REVERSE OSMOSIS SYSTEM KEY FEATURES Water Saving Technology – Patented technology eliminates backpressure The RC100 conforms to common in conventional RO systems making the Circle up to 10 times more NSF/ANSI 42, 53 and efficient than existing products. 58 for the reduction of Saves You Money – Conventional RO systems waste up to 24 gallons of Aesthetic Chlorine, Taste water per every 1 gallon of filtered water produced. The Circle only wastes and Odor, Cyst, VOCs, an average of 2.1 gallons of water per 1 gallon of filtered water produced, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium, Hexavalent saving you water and money over the life of the product!. Chromium, Trivalent Chromium, Lead, RO Filter Auto Flushing – Significantly extends life of RO filter. Copper, Selenium and TDS as verified Chrome Faucet Included – With integrated LED filter change indicator. and substantiated by test data. The RC100 conforms to NSF/ANSI 372 for Space Saving Compact Design – Integrated rapid refill tank means more low lead compliance. space under the sink. SPECIFICATIONS Product Name H2O+ Circle Reverse Osmosis Water Filtration System Model / SKU RC100 Installation Undercounter Sediment Filter, Pre-Carbon Plus Filter, Post Carbon Block Filter (RF-20): 6 months Filters & Lifespan RO Membrane Filter (RF-40): 24 months Tank Capacity 6 Liters (refills fully in less than one hour) Dimensions 9.25” (W) x 16.5” (H) x 13.75” (D) Net weight 14.6 lbs Min/Max Operating Pressure 40 psi – 120 psi (275Kpa – 827Kpa) Min/Max Water Feed Temp 41º F – 95º F (5º C – 35º C) Faucet Flow Rate 0.26 – 0.37 gallons per minute (gpm) at incoming water pressure of 20–100 psi Rated Service Flow 0.07 gallons per minute (gpm) Warranty One Year Warranty PO Box 470085, San Francisco CA, 94147–0085 brondell.com 888-542-3355.
    [Show full text]
  • Sedimentation and Clarification Sedimentation Is the Next Step in Conventional Filtration Plants
    Sedimentation and Clarification Sedimentation is the next step in conventional filtration plants. (Direct filtration plants omit this step.) The purpose of sedimentation is to enhance the filtration process by removing particulates. Sedimentation is the process by which suspended particles are removed from the water by means of gravity or separation. In the sedimentation process, the water passes through a relatively quiet and still basin. In these conditions, the floc particles settle to the bottom of the basin, while “clear” water passes out of the basin over an effluent baffle or weir. Figure 7-5 illustrates a typical rectangular sedimentation basin. The solids collect on the basin bottom and are removed by a mechanical “sludge collection” device. As shown in Figure 7-6, the sludge collection device scrapes the solids (sludge) to a collection point within the basin from which it is pumped to disposal or to a sludge treatment process. Sedimentation involves one or more basins, called “clarifiers.” Clarifiers are relatively large open tanks that are either circular or rectangular in shape. In properly designed clarifiers, the velocity of the water is reduced so that gravity is the predominant force acting on the water/solids suspension. The key factor in this process is speed. The rate at which a floc particle drops out of the water has to be faster than the rate at which the water flows from the tank’s inlet or slow mix end to its outlet or filtration end. The difference in specific gravity between the water and the particles causes the particles to settle to the bottom of the basin.
    [Show full text]
  • Crystallization of Oxytetracycline from Fermentation Waste Liquor: Influence of Biopolymer Impurities
    Journal of Colloid and Interface Science 279 (2004) 100–108 www.elsevier.com/locate/jcis Crystallization of oxytetracycline from fermentation waste liquor: influence of biopolymer impurities Shi-zhong Li a,1, Xiao-yan Li a,∗, Dianzuo Wang b a Environmental Engineering Research Centre, Department of Civil Engineering, The University of Hong Kong, Hong Kong, China b Chinese Academy of Engineering, Beijing 100038, China Received 28 January 2004; accepted 17 June 2004 Available online 29 July 2004 Abstract Organic impurities in the fermentation broth of antibiotic production impose great difficulties in the crystallization and recovery of antibi- otics from the concentrated waste liquor. In the present laboratory study, the inhibitory effect of biopolymers on antibiotic crystallization was investigated using oxytetracycline (OTC) as the model antibiotic. Organic impurities separated from actual OTC fermentation waste liquor by ultrafiltration were dosed into a pure OTC solution at various concentrations. The results demonstrated that small organic molecules with an apparent molecular weight (AMW) of below 10,000 Da did not affect OTC crystallization significantly. However, large biopolymers, especially polysaccharides, in the fermentation waste caused severe retardation of crystal growth and considerable deterioration in the pu- rity of the OTC crystallized. Atomic force microscopy (AFM) revealed that OTC nuclei formed in the solution attached to the surfaces of large organic molecules, probably polysaccharides, instead of being surrounded by proteins as previously thought. It is proposed that the attachment of OTC nuclei to biopolymers would prevent OTC from rapid crystallization, resulting in a high OTC residue in the aqueous phase. In addition, the adsorption of OTC clusters onto biopolymers would destabilize the colloidal system of organic macromolecules and promote particle flocculation.
    [Show full text]
  • Recommended Standards for Water Works 2007 Edition
    Recommended Standards for Water Works 2007 Edition Policies for the Review and Approval of Plans and Specifications for Public Water Supplies A Report of the Water Supply Committee of the Great Lakes--Upper Mississippi River Board of State and Provincial Public Health and Environmental Managers MEMBER STATES AND PROVINCE Illinois Indiana Iowa Michigan Minnesota Missouri New York Ohio Ontario Pennsylvania Wisconsin Published by: Health Research Inc., Health Education Services Division, P.O. Box 7126, Albany, NY 12224 (518)439-7286 www.hes.org Copyright © 2007 by the Great Lakes - Upper Mississippi River Board of State and Provincial Public Health and Environmental Managers This book, or portions thereof, may be reproduced without permission from the author if proper credit is given. TABLE OF CONTENTS FOREWORD POLICY STATEMENT ON PRE-ENGINEERED WATER TREATMENT PLANTS POLICY STATEMENT ON AUTOMATED/UNATTENDED OPERATION OF SURFACE WATER TREATMENT PLANTS POLICY STATEMENT ON BAG AND CARTRIDGE FILTERS FOR PUBLIC WATER SUPPLIES POLICY STATEMENT ON ULTRA VIOLET LIGHT FOR TREATMENT OF PUBLIC WATER SUPPLIES POLICY STATEMENT ON INFRASTRUCTURE SECURITY FOR PUBLIC WATER SUPPLIES POLICY STATEMENT ON ARSENIC REMOVAL INTERIM STANDARD - NITRATE REMOVAL USING SULFATE SELECTIVE ANION EXCHANGE RESIN INTERIM STANDARD - USE OF CHLORAMINE DISINFECTANT FOR PUBLIC WATER SUPPLIES INTERIM STANDARD ON MEMBRANE TECHNOLOGIES FOR PUBLIC WATER SUPPLIES PART 1 - SUBMISSION OF PLANS 1.0 GENERAL 1.1 ENGINEER’S REPORT 1.1.1 General Information 1.1.2 Extent of water works
    [Show full text]
  • Dissolved Organic Carbon (DOC) (For Private Water and Health Regulated Public Water Supplies)
    Dissolved Organic Carbon (DOC) (For Private Water and Health Regulated Public Water Supplies) What Is Dissolved Organic Carbon? Dissolved organic carbon (DOC) is a general description of the organic material dissolved in water. Organic carbon occurs as the result of decomposition of plant or animal material. Organic carbon present in soil or water bodies may then dissolve when contacted by water. This dissolved organic carbon moves with both surface water and ground water. Acknowledgement: How Does Dissolved Organic Carbon Get Into Water? Organic material (including carbon) results from decomposition of plants or animals. This Fact Sheet is one of a Once this decomposed organic material contacts water it may partially dissolve. series developed by an Interagency Committee with representatives from How Does Dissolved Organic Carbon Affect My Health? Saskatchewan Ministry of DOC does not pose health risk itself but may become potentially harmful when in Health, Regional Health combination with other aspects of your water. When water with high DOC is Authorities, Saskatchewan chlorinated, harmful byproducts called trihalomethanes may be produced (see Watershed Authority, SaskH2O factsheet on trihalomethanes). Trihalomethanes may have long-term Saskatchewan Ministry of effects on health and they should be considered when chlorinating drinking water Environment, Saskatchewan Ministry of Agriculture, high in DOC. According to Health Canada, the benefits of chlorinating drinking Agriculture and Agri-Food water are much greater than the health risks associated with chlorination by- Canada – PFRA and Health products such as trihalomethanes Canada. DOC can interfere with the effectiveness of disinfection processes such as Responsibility for chlorination, ultraviolet and ozone sterilization. DOC can also promote the growth of interpretation of the content of microorganisms by providing a food source.
    [Show full text]
  • Turbidity Analysis for Oregon Public Water Systems Water Quality in Coast Range Drinking Water Source Areas June 2010
    Report Turbidity Analysis for Oregon Public Water Systems Water Quality in Coast Range Drinking Water Source Areas June 2010 Last Updated: 06/29/10 By: Joshua Seeds DEQ 09-WQ-024 This report prepared by: Oregon Department of Environmental Quality 811 SW 6th Avenue Portland, OR 97204 1-800-452-4011 Contact: Joshua Seeds (503) 229-5081 [email protected] Turbidity Analysis for Oregon Public Water Systems Table of Contents Table of Contents .......................................................................................... i List of Figures .............................................................................................. iii List of Tables ............................................................................................... iiv List of Maps ................................................................................................. iiv Executive Summary ..................................................................................... 1 Introduction .................................................................................................. 2 Applicable Turbidity Standards for Water Quality ............................................... 2 Public Water System Evaluations....................................................................... 3 Methods .......................................................................................................................... 5 Definitions of terms........................................................................................................
    [Show full text]
  • State-Of-The-Art Water Treatment in Czech Power Sector
    membranes Article State-of-the-Art Water Treatment in Czech Power Sector: Industry-Proven Case Studies Showing Economic and Technical Benefits of Membrane and Other Novel Technologies for Each Particular Water Cycle Jaromír Marek Department of Chemistry, Faculty of Science, Humanities and Education, Technical University of Liberec, Studentská 1402/2, 461 17 Liberec, Czech Republic; [email protected]; Tel.: +420-732-277-183 Abstract: The article first summarizes case studies on the three basic types of treated water used in power plants and heating stations. Its main focus is Czechia as the representative of Eastern European countries. Water as the working medium in the power industry presents the three most common cycles—the first is make-up water for boilers, the second is cooling water and the third is represented by a specific type of water (e.g., liquid waste mixtures, primary and secondary circuits in nuclear power plants, turbine condensate, etc.). The water treatment technologies can be summarized into four main groups—(1) filtration (coagulation) and dosing chemicals, (2) ion exchange technology, (3) membrane processes and (4) a combination of the last two. The article shows the ideal industry-proven technology for each water cycle. Case studies revealed the economic, technical and environmental advantages/disadvantages of each technology. The percentage of Citation: Marek, J. State-of-the-Art technologies operated in energetics in Eastern Europe is briefly described. Although the work is Water Treatment in Czech Power conceived as an overview of water treatment in real operation, its novelty lies in a technological model Sector: Industry-Proven Case Studies of the treatment of turbine condensate, recycling of the cooling tower blowdown plus other liquid Showing Economic and Technical waste mixtures, and the rejection of colloidal substances from the secondary circuit in nuclear power Benefits of Membrane and Other plants.
    [Show full text]
  • Publication No. 17: Ozone Treatment of Private Drinking Water Systems
    PRIVATE DRINKING WATER IN CONNECTICUT Publication Date: April 2009 Publication No. 17: Ozone Treatment of Private Drinking Water Systems Effective Against: Pathogenic (disease-causing) organisms including bacteria and viruses, phenols (aromatic organic compounds), some color, taste and odor problems, iron, manganese, and turbidity. Not Effective Against: Large cysts and some other large organisms resulting from possible or probable sewage contamination, inorganic chemicals, and heavy metals. How Ozone (O3) Treatment Works Ozone is a chemical form of pure oxygen. Like chlorine, ozone is a strong oxidizing agent and is used in much the same way to kill disease-causing bacteria and viruses. It is effective against most amoebic cysts, and destroys bacteria and some aromatic organic compounds (such as phenols). Ozone may not kill large cysts and some other large organisms, so these should be eliminated by filtration or other procedures prior to ozone treatment. Ozone is effective in eliminating or controlling color, taste, and odor problems. It also oxidizes iron and manganese. Ozone treatment units are installed as point-of-use treatment systems. Raw water enters one opening and treated water emerges from another. Inside the treatment unit, ozone is produced by an electrical corona discharge or ultraviolet irradiation of dry air or oxygen. The ozone is mixed with the water whenever the water pump is running. Ozone generation units require a system to clean and remove the humidity from the air. For proper disinfection the water to be treated must have negligible color and turbidity levels. The system requires routine maintenance and an ozone treatment system can be very energy consumptive.
    [Show full text]
  • A Lexicon of Alchemy
    A Lexicon of Alchemy by Martin Rulandus the Elder Translated by Arthur E. Waite John M. Watkins London 1893 / 1964 (250 Copies) A Lexicon of Alchemy or Alchemical Dictionary Containing a full and plain explanation of all obscure words, Hermetic subjects, and arcane phrases of Paracelsus. by Martin Rulandus Philosopher, Doctor, and Private Physician to the August Person of the Emperor. [With the Privilege of His majesty the Emperor for the space of ten years] By the care and expense of Zachariah Palthenus, Bookseller, in the Free Republic of Frankfurt. 1612 PREFACE To the Most Reverend and Most Serene Prince and Lord, The Lord Henry JULIUS, Bishop of Halberstadt, Duke of Brunswick, and Burgrave of Luna; His Lordship’s mos devout and humble servant wishes Health and Peace. In the deep considerations of the Hermetic and Paracelsian writings, that has well-nigh come to pass which of old overtook the Sons of Shem at the building of the Tower of Babel. For these, carried away by vainglory, with audacious foolhardiness to rear up a vast pile into heaven, so to secure unto themselves an immortal name, but, disordered by a confusion and multiplicity of barbarous tongues, were ingloriously forced. In like manner, the searchers of Hermetic works, deterred by the obscurity of the terms which are met with in so many places, and by the difficulty of interpreting the hieroglyphs, hold the most noble art in contempt; while others, desiring to penetrate by main force into the mysteries of the terms and subjects, endeavour to tear away the concealed truth from the folds of its coverings, but bestow all their trouble in vain, and have only the reward of the children of Shem for their incredible pain and labour.
    [Show full text]