Keysight M9037A Pxie Embedded Controller
Total Page:16
File Type:pdf, Size:1020Kb
User Guide Keysight M9037A PXIe Embedded Controller Notices © Keysight Technologies, Inc. 2014 Sales and Technical Support Warranty No part of this manual may be repro- To contact Keysight for sales and techni- THE MATERIAL CONTAINED IN THIS duced in any form or by any means cal support, refer to the support links on DOCUMENT IS PROVIDED “AS IS,” AND (including electronic storage and retrieval the following Keysight websites: IS SUBJECT TO BEING CHANGED, or translation into a foreign language) WITHOUT NOTICE, IN FUTURE EDI- without prior agreement and written con- www.keysight.com/find/M9195A (prod- TIONS. FURTHER, TO THE MAXIMUM sent from Keysight Technologies, Inc. as uct-specific information and support, EXTENT PERMITTED BY APPLICABLE governed by United States and interna- software and documentation updates) LAW, KEYSIGHT DISCLAIMS ALL WAR- tional copyright laws. www.keysight.com/find/assist (world- RANTIES, EITHER EXPRESS OR IMPLIED, wide contact information for repair and WITH REGARD TO THIS MANUAL AND Manual Part Number service) ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED M9037-90005 Information on preventing damage to TO THE IMPLIED WARRANTIES OF MER- your Keysight equipment can be found at CHANTABILITY AND FITNESS FOR A Edition www.keysight.com/find/tips. PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR Third Edition, September 2014 Declaration of Conformity FOR INCIDENTAL OR CONSEQUENTIAL Printed in Malaysia DAMAGES IN CONNECTION WITH THE Declarations of Conformity for this prod- FURNISHING, USE, OR PERFORMANCE uct and for other Keysight products may OF THIS DOCUMENT OR OF ANY INFOR- Keysight Technologies, Inc. be downloaded from the Web. Go to MATION CONTAINED HEREIN. SHOULD 1400 Fountaingrove Parkway http://keysight.com/go/conformity and KEYSIGHT AND THE USER HAVE A SEP- Santa Rosa, CA 95403 USA click on “Declarations of Conformity.” You ARATE WRITTEN AGREEMENT WITH can then search by product number to WARRANTY TERMS COVERING THE find the latest Declaration of Conformity. MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE Technology Licenses WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL. The hardware and/or software described Keysight Technologies does not warrant in this document are furnished under a third-party system-level (combination of license and may be used or copied only in chassis, controllers, modules, etc.) per- accordance with the terms of such Trademarks formance, safety, or regulatory compli- license. ance unless specifically stated. AXIe is a registered trademark of the AXIe Consortium. DFARS/Restricted Rights PXI is a registered trademark of the PXI Notices Systems Alliance. If software is for use in the performance PICMG®, Compact PCI®, and ® of a U.S. Government prime contract or AdvancedTCA are registered trade- subcontract, Software is delivered and marks of the PCI Industrial Computer licensed as “Commercial computer soft- Manufacturers Group. ware” as defined in DFAR 252.227-7014 ® ® ® (June 1995), or as a “commercial item” as PCI-SIG , PCI Express , and PCIe are registered trademarks of PCI-SIG. defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Keysight Technologies’ stan- dard commercial license terms, and non- DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Gov- ernment users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227- 7015 (b)(2) (November 1995), as applica- ble in any technical data. Safety Information The following general safety precau- Do Not Remove Instrument Cover tions must be observed during all Only qualified, service-trained person- phases of operation of this instrument. nel who are aware of the hazards Failure to comply with these precau- involved should remove instrument tions or with specific warnings or oper- covers. Always disconnect the power Do NOT block vents and fan exhaust: ating instructions in the product cable and any external circuits before To ensure adequate cooling and venti- manuals violates safety standards of removing the instrument cover. lation, leave a gap of at least 50mm design, manufacture, and intended use (2") around vent holes on both sides of of the instrument. Keysight Technolo- Keep away from live circuits the chassis. gies assumes no liability for the cus- tomer's failure to comply with these Operating personnel must not remove Do NOT operate with empty slots: To requirements. equipment covers or shields. Proce- ensure proper cooling and avoid dam- dures involving the removal of covers aging equipment, fill each empty slot and shields are for use by service- with an AXIe filler panel module. General trained personnel only. Under certain Do NOT stack free-standing chassis: Do not use this product in any manner not conditions, dangerous voltages may exist even with the equipment Stacked chassis should be rack- specified by the manufacturer. The protec- switched off. To avoid dangerous elec- mounted. tive features of this product must not be trical shock, DO NOT perform proce- All modules are grounded through the impaired if it is used in a manner specified in dures involving cover or shield removal chassis: During installation, tighten the operation instructions. unless you are qualified to do so. each module's retaining screws to Before Applying Power DO NOT operate damaged secure the module to the chassis and to make the ground connection. Verify that all safety precautions are taken. equipment Make all connections to the unit before Whenever it is possible that the safety applying power. Note the external markings protection features built into this prod- described under “Safety Symbols”. uct have been impaired, either through physical damage, excessive moisture, Ground the Instrument or any other reason, REMOVE POWER Keysight chassis’ are provided with a and do not use the product until safe grounding-type power plug. The operation can be verified by service- Operator is responsible to maintain instrument chassis and cover must be trained personnel. If necessary, return safe operating conditions. To ensure connected to an electrical ground to the product to an Keysight Technolo- safe operating conditions, modules minimize shock hazard. The ground pin gies Sales and Service Office for ser- should not be operated beyond the full must be firmly connected to an electri- vice and repair to ensure the safety temperature range specified in the cal ground (safety ground) terminal at features are maintained. Environmental and physical specifica- the power outlet. Any interruption of tion. Exceeding safe operating condi- the protective (grounding) conductor DO NOT block the primary tions can result in shorter lifespan, or disconnection of the protective disconnect improper module performance and user safety issues. When the modules earth terminal will cause a potential The primary disconnect device is the are in use and operation within the shock hazard that could result in per- appliance connector/power cord when specified full temperature range is not sonal injury. a chassis used by itself, but when maintained, module surface tempera- installed into a rack or system the dis- tures may exceed safe handling condi- Do Not Operate in an Explosive connect may be impaired and must be tions which can cause discomfort or Atmosphere considered part of the installation. Do not operate the module/chassis in burns if touched. In the event of a the presence of flammable gases or Do Not Modify the Instrument module exceeding the full temperature fumes. range, always allow the module to cool Do not install substitute parts or per- before touching or removing modules form any unauthorized modification to Do Not Operate Near Flammable from the chassis. Liquids the product. Return the product to an Keysight Sales and Service Office to Do not operate the module/chassis in ensure that safety features are main- the presence of flammable liquids or tained. near containers of such liquids. In Case of Damage Cleaning Instruments that appear damaged or Clean the outside of the Keysight mod- defective should be made inoperative ule/chassis with a soft, lint-free, and secured against unintended oper- slightly dampened cloth. Do not use ation until they can be repaired by detergent or chemical solvents. qualified service personnel iv Safety Symbols A CAUTION denotes a hazard. It calls attention to an operating pro- cedure or practice, that, if not cor- The CSA mark is a registered trade- rectly performed or adhered to mark of the Canadian Standards Asso- South Korean Class A EMC Declara- could result in damage to the ciation and indicates compliance to tion. this equipment is Class A suitable product or loss of important data. the standards laid out by them. Refer for professional use and is for use in Do not proceed beyond a CAUTION to the product Declaration of Confor- electromagnetic environments outside notice until the indicated condi- mity for details. of the home. tions are fully understood and met. Notice for European Community: This product complies with the relevant A WARNING denotes a hazard. It European legal Directives: EMC Direc- calls attention to an operating pro- tive (2004/108/EC) and Low Voltage cedure or practice, that, if not cor- Directive (2006/95/EC). rectly performed or adhered to, could result in personal injury or death. Do not proceed beyond a Waste Electrical and WARNING notice until the indi- Electronic cated conditions are fully under- Equipment (WEEE) stood and met. The Regulatory Compliance Mark Directive Products display the following sym- (RCM) mark is a registered trademark. 2002/96/EC bols: This signifies compliance with the Aus- tralia EMC Framework regulations This product complies with the WEEE under the terms of the Radio Commu- Directive (2002/96/EC) marking Warning, risk of electric nication Act of 1992.