IIInInnnspirispirispiringngngng TTTeTeeechnochnochnollllooooggggyyyy

13, 14, 1515,,,,“SUN ENCLAVE”, NEAR SUNCITY PARADISE, MANJALPUR, VADODARAVADODARA----390020390020390020,,,, GUJARAT –––INDIA [email protected] www.laxmiassociates.in Mob. -00919374076950 Overview on Activities

 Testing & Commissioning  Condition Assessment  Residual Life Assessment  Asset Management  System Study & Consultancy  Training  Third Party Inspection  NABL approved oil testing Lab (GEL)

“LA is a leading and reputed service provider group of India” Different Level of Services

RLA studies and condition assessment of power transformers, bushings, CTs, cables, generators, Lightning Arresters (LAs) and other HV equipment, Low Voltage (LV) and Medium Voltage (MV) switchgear panels.

Specialised testing and commissioning services for power system equipment, complete Sub-station including GIS & Switchyards up to 765 kV.

Annual Maintenance Contract (AMC) services for Sub-station, Switchgear and Transformer equipment for condition based maintenance (CBM) & on-site diagnostic test.

Asset management, Health Indexing of Power transformer & HV Electrical equipment in system for Risk assessment, Reliability study, Cost effective Maintenance planning & Phase wise Planned replacement of aging Asset.

Certified Auditors for Third party testing and inspection in the factory and at site by various utility.

Customer specific Training, System study & Consultancy in High Voltage Engineering, Transmission and Distribution sector of Power.

Specialized Fault Finding Services by our panel of Experts based on latest diagnostic services carried on site by our team that includes AE & Electrical Partial discharge, Tan Delta, SFRA, On –line Thermography , MCSA, VLF for cable, On-line leakage current monitoring (LCM) for LA, On-line Moisture Assessment (Domino), Tan de Moisture Analysis by FDS & PDS (DIRANA) , Relay test , CT analyser for locating problems in power system & Transformer and recommendation for suitable rectification services on time Working at Domestic & International level in private sector companies, Semi-Govt. & Govt. undertakings as well as Public Sector organizations and Govt. Principles like:

PGCIL Substations : (Power Grid Corporation of India Ltd) UPPCL S/s

NTPC and its Joint ventures HVPNL S/s TATA POWER ULTRATECH CEMENT ADANI POWER RVPNL S/s IOCL DTL - TRANSCO LIMITED TORRENT POWER JAYPEE GROUP ONGC SAIL GAIL AVANTHA GROUP ESSAR ORIENT PAPER MILLS RIL () JK PAPER MILLS JINDAL STEEL (JSPL & JSW) AIA ENGINEERING NTECL HINDALCO NTPL RSP (Rourkela Steel Plant) NPCIL AP TRANSCO APCPL TNEB PLASMA REASERCH SUN PHARMA RRVUNL GSFC CSPGCL Megha Engg. Hydrabad HPGCL – PTPS CII (Confederation of Indian Industries) GETCO S/s Future Energy Bio-Power Pvt. Ltd. – SRILANKA CSPTCL S/s TANESCO S/s – AFRICA BSEB – BSPHCL IDC Technology – AUSTRALIA BSPTCL S/s RAY International – OMAN OPTCL S/s INDE – NORTH AMERICA WBSETCL S/s D & J – DUBAI Testing & Commissioning

 LA is recognised as the high voltage substation Testing ,Commissioning company in India, with a capacity of substations from 11kV to 765kV.

 765/400 KV Testing and Commissioing of Transformer, REACTOR, NCT, NGR, LA, CT, PT, CB etc. at :

 PGCIL Moga, Hamirpur, Makhu, Muksar, Nakodar, Chanigardh,Amritsar, Bhiwani, Meerut, Zatikara, Agra, Jaipur

 PGCIL Jayepur, Indrawati, Durgapur, Maithon, Gaya, Bihar Sarif, Fathepur, Lucknow, Sasaram,

 PGCIL Bina, Satna, Gwalior, Sujalpur, Bilaspur, Raipur, Raigardh, Jabalpur, Angul, Jhasugoda

 PGCIL Kasor, Bhachau (MUNDRA), Limbdi, Pirana, Jayepur, Indrawati, Durgapur, Maithon

 CGPL Mundra Ultra Mega POWER PROJECTS

 Sterlite project for Bhopal Dhule Transmission at 765 kV Project

 Megha Engineering Switchyard project , 400 kV, PGCIL Kunta, Ghanni, Narshapur

 NTPC Vindhnagar, Rihand, Mauda, Kanti, Jajhhar, Dadri, Ramakundan, Solapur, Kudgi

 CSPTCL , UPRVNL, MPGVCL, UPTCL, DTL, IPR, Naiveli Lignite Power Plant

 NPCIL Kakrapada, Kalpakam

 Various TATA PROJECTS in MUMBAI & Other parts of India

 HPGCL Panipath, IOCL Viramgam, Vadodara,Panipath

 GETCO Anjar, Charanka, Limbdi and various old substation as relocation and refurbishment work

 RIL Plant, Various Refinery , Steel, Process & Cement Plants

 TAMAS, SEB MALAYSIA

Our Achievements: 1200 kV Transformer first time in INDIA is tested and commissioned by our company in PGCIL-BINA – 1200 kV PROJECT Testing Instruments No. Instruments Description Units 1 OMICRON CPC100 (with CP TD1) – Multifunction Test Set 3 Omicron make Set, To measure Tan Delta (0-12 kV), Ratio & Polarity/Tap Changer, Contact resistance & Winding Resistance, Earth Resistance, Ratio-Polarity-Burden- Resistance and Excitation Curve, dielectric withstand voltage test (2 kV AC), Primary injection range 0-800A AC & 0-400A DC. 2 Megger Delta4110 Tangent Delta/Power Factor Test System 3 Megger Make test set, To measure Tan Delta (0-12 kV) 3 Acoustic Partial Discharge – PDL-650 2 Omicron Make, PDL-550 & PDL-650 with accessories 4 FRAX-101 (MEGGER) – SFRA 3 Megger Make test set, for Sweep Frequency Response Analysis 5 FRAnalyzer (OMICRON) – SFRA 2 Omicron Make test set, for Sweep Frequency Response Analysis 6 DIRANA (OMICRON) 2 Omicron Make test set, for Moisture Assessment by FDS & PDC combine method – Dielectric properties 7 ATRT-01 S3 (VANGUARD) 2 Vanguard Make test set, Automatic Transformer Ratio Meter including 15 meters long cables set 8 CT Analyser (OMICRON) 2 Eltel Make test set, Transformer Winding Resistance Meter including 15 meters long cables set 9 Digital High Voltage Insulation Tester 6 Kyoritsu and Megger Make Instruments, To measure Insulation resistance level, 0-5 kV with long cables No. Instruments Description Units 10 TRM-10 (SCOPE) 2 Scope Make test set, Transformer Winding Resistance Meter

11 FLIR i5 – Camera 2 FLIR Make Instrument, for thermo vision scanning 12 Digital Vibration Meter 2 IRD Mechanalysis Make Instrument, for Vibration Measurement (Velocity-200 mm/sec RMS and Displacement-2000 microns pk-pk) 13 Digital Sound Level Meter 2 IRD Mechanalysis Make Instrument, for Noise Level Measurement (60 to 120 dB) 14 High Current Source 6 Primary Injection Set, OMICRON & MOONLIGHT Make, 0-3500 A 15 High Voltage Source 4 High Voltage Injection, OMICRON/Moon Light Make, 0-5 kV 16 Digital Earth Resistance Meter 2 MEGGER/WACO Make, 0-10-1000 Ω 17 Digital Multimeters , Clamp-On Meter, Leakage Meter 7 Fluke,Kyoritsu, Meco Make 18 LCM (Third harmonic leakage current Monitor) for LA testing 2 Doble/Scope Make 19 Dynamic current resistance measurement (DCRM) for Circuit breaker analyser 2 Scope/Omicron Make 20 Relay test kit 2 Omicron CMC 356 22 VLF TEST /Cable Fault locator 1 23 Domino- DOBLE MAKE 1 On-Site Diagnostic & RLA Test

 Condition assessment and RLA Test including site- Inspection on various equipment used in power generation, transmission and distribution.

 Experienced engineers over 20 years in maintenance management with consistent record of reducing the maintenance cost.

 Enhancing the machine availability with specialization in condition based predictive maintenance are there in the team to for executing the job. TEST carried out by latest equipment and by a fleet of experienced engineer On-Site Test for RLA & Condition Assessment

Bushings,PotentialTransformersandCVTs PowerTransformers • Winding Resistance Measurement, • Capacitance and dissipation factor measurement of the main • Voltage Ratio and Vector group confirmation test, insulation and bushings. • No-load excitation current measurement • Moisture analysis of paper insulation by dielectric method . • Capacitance and dissipation factor measurement of the main insulation and bushings • Impedance measurements (short-circuit impedance) SurgeArrestors (LA) • Sweep Frequency Response Analysis (SFRA), • Leakage Current measurement (LCM) • Partial discharge measurements of power transformers • Capacitance and dissipation factor measurement of the inner • Moisture analysis of paper insulation by dielectric method . insulation on per stack basis • OLTC DCRM test • DGA , DP and Furan test PowerCable • Capacitance and dissipation factor measurement of the inner insulation CurrentTransformers • Partial discharge measurements • CT winding resistance measurement • Oil test in case of oil filled cable • CT excitation characteristic according to IEC 60044-1 and IEEE • Resistance measurement of cable C57.13. for knee-point voltages . • CT ratio measurement, phase and polarity measurement Circuit breaker • Determination of accuracy limiting factor, instrument security factor,Test of CTs for knee-point voltages. • CR M, DCRM, Partial discharge, Capacitance & Tan delta • Capacitance and dissipation factor measurement of the main • measurement of insulation, Winding DC resistance insulation and bushings • Partial discharge measurements of CTs. Moisture analysis of paper insulation by dielectric method . • Motor & Generator • ON LINE Motor current signature analysis(MCSA), Vibration test, • Stator windings, IR & PI, Partial discharge, Capacitance & Tan delta measurement of insulation, Winding DC resistance Condition Assessment Services for Transformers & Switchyard equipment

Ratio Measurement Winding resistance C-TanDelta of bushings C-TanDelta of winding insulation Measurement of water content in insulation Winding and core paper diagnosis with FRA Partial Discharge Short circuit Measurement DP , FURAN TEST Impedance measurement OIL TEST Condition Assessment & RLA Services for Rotating Machines

C-TanDelta of Measurement of winding insulation moisture content in the stator insulation (FDS + PDC measurement) Detection of broken conductors in damping windings with FRA Partial Discharge measurement Resistance on stator Measurement of Impedance windings Online stator and rotor measurement on and Offline windings single pole rotors Assessment & Interpretation of Test Data

dB 200 300 500 700 10 00 2000 30 00 f/Hz -30

-40

-50 -60 SFR A -70

-80

-90

UV V W W U Counts

Charge Phase Interpretation and consulting by panel of Expert in Industry Assessment & Interpretation of Test Data

Detailed analysis of test data for assessing the health of Transformer based on various diagnostics test like: No load excitation, leakage reactance tests, SFRA, Partial Discharge tests Capacitance and Power factor, Dissolved Gas Analysis, Furanic Compounds in Oil Degree of Polymerization, Corrosive Sulphur test of oil.

Detailed analysis of test data for assessing the Interpretation and health of HV equipments such as Circuit consulting by panel of breaker, Generators, Current Transformer, Expert in Industry Potential transformer, Lightening arrestor, CVT,Cable, Bushings etc. NABL APPROVED OIL TEST LAB (GEL) RLA Projects Major RLA Jobs Completed at…  PGCIL-Panipath  Institute of PLASMA REASERCH, Ahmedabad  RELIANCE Jamnagar, Hazira, Silvasa, Vadodara & Patalganga  HPGCL – Panipat  NTPC – Ramagundam  CSPTCL- Bhellai  UPVRNL-Anpara  Neyveli Lignite TPS II  Various Steel, Cement & Process Plants in India  SEB Malaysia Third party inspection services

We offers Independent Factory & Site inspection of HV equipments as per relevant WeIEC/ offers IEEE Independentfor quality check Factory during & Site inspectionmanufacturing of HV process equipments and type, as routineper relevant test. IEC Customer Specific Training (On-site Training)

Combines Theory and Hands-on Applications

 Customized your needs  Classroom Training  Hands-on field testing  Analysis of Test data KEY Training Assignments by Our Experts

 Conducted Two Days Workshop on Asset management & life cycle management of Transformer in Delhi , Mumbai, Hydrabad by Knowledge cluster , 2015-17  Conducted Three Day Workshop on Best practices of life cycle management of Switchgears in Malaysia , TAMAS , Nov. 2014.  Conducted Three Day Workshop on Best practices of life cycle management of Transformer in Malaysia , TAMAS , May. 2014.  Conducted One Day Training on Asset Management of Transformer in Delhi , NTPC, PMI , NOIDA , Jan. 2014.  Conducted Two days Training on Reliabilty, Maintence, Basics and Protection of Transformer, for Corporate Training Programme in Reliance Industries Limited, Jamnager designed for Managers in Operation , Maintenance & Planning at Various plant location , also known as “ Reliance Certified Electrical Engineers (RCEE) programme” in October 2013 & 2014.  Conducted Five Day Workshop on Best O&M Practices of Transformer and Substation in Malysia , KL, for IDC Technologies , Australia , October. 2012.  Conducted Workshop on On line and offline condition assessment of Transformer, Bushings CT in 400 kV Substation , designed for Managers in Operation , Maintenance from Various location of India in PGCIL (Power Grid Corporation of India) ,and conducted in PGCIL Jammu APRIL 2011 .  Conducted Two Day Workshop on Best O&M Practices of Transformer and Substation in ISPT Pune , conducted by IDC Technologies , Australia ,Feb. 2011.  Conducted One Day Workshop on Failure investigation by SFRA ANALYSIS and Moisture assessment designed for enginners in Operation , Maintenance from Various location of India in PGCIL ,and conducted at PGCIL Chandigadh, Nov. 2010 .  Conducted "Tutorial on Interpretation of SFRA test data for Incipient fault detection in Transformer." i n DMPT Singapur, March 2010.  Conducted One Day Tutorial on Advanced diagnostic techniques of Power Transformer in CBIP International conference, Delhi, India, November 2009.  Conducted One week Training & Consulting Assignment for Condition assessment and RLA of Transformer, CT, Bushing in Transmission Utility of INDONESIA, PLN., Jakarta., August 2009.  Conducted Two days Training for Condition assessment of Transformer, and Failure investigation by SFRA ANALYSIS designed for Managers in Operation , Maintenance from Various location of India in PGCIL (Power Grid Corporation of India) ,and conducted in PGCIL Banglore APRIL 2009 . LA Engineering Academy

 The course content is designed for engineers in the field of Power Generation, Transmission, Distribution. The course also educates the new recruits by providing both practical and theoretical exposures. All course will be delivered by the experts having sound field engineering practice backed by relevant theory and operating principle to enrich the training program. The course structure is designed in 2 level package as mentioned below.

 Level 1- Advance Course on Asset Management for T&D system from Expert of the Industry

 Level 2- General course on Condition assessment of Equipment

Details about the Training Course content is available at http://www.laxmiassociates.in Panel of EXPERTS

 Dr. Aradhana Ray (Power Consultant)  Dr. B.P Singh (Ex. GM, BHEL Corporate R&D, Hyderabad.)  Dr. V. Shrinet (Ex. Deputy Director, ERDA)  Dr. Krishnamoorthy (Ex. Deputy Director, ERDA)  Er. Halim Osman(Ex. GM, TNB, Malaysia Asset Management)

Details about the Training Course content is available at http://www.laxmiassociates.in Consultancy

Power Generation Consultancy in area of System study, Transmission Design review, formulation of specification for all types of Electrical Distribution product & engineering support to the Client’s for their Asset management in By panel of area of High Voltage equipments, experts in Substation equipment diagnostic and failure issues and carrying out the power sector stage Inspection. for consultancy assignment. Consultancy Assignments

Certified Technical writer for IDC Technologies, Australia for development of various Technical manual and Technical Course in for utility in Australia, Canada & USA.

Consultant to D&J Dubai, a PMC (Project Management & Consultant) company working in Dubai & UAE.

Consultancy for Reliance Industries, India

Consultancy for RAY International, Oman

Completed Third Party Factory inspection for Power Transformer (220 kV and Above, approx. 50 nos.) for Transmission utility in North America, INDE & South Africa from 2007.

Health Index , Risk assessment and Asset Management project for SEB Malaysia for the Transmission , Distribution and Generation system Asset Management Project

Focused asset life cycle Strategies and solutions by Health Index , Probability of failure estimation

Establishing sub-asset management system or framework for critical asset group and application

Discovering fundamental gaps and opportunities in developing risk-based fleet management capabilities for specific asset group

Detailed and complete multi year life cycle plan, optimized CAPEX and OPEX KEY Customers

Power Grid Corp. Ltd. (PGCIL) Alstom Ltd. ABB Ltd. Delhi Transco Ltd. EMCO Ltd. L&T Ltd (Projects division) HPGCL, Panipath Areva Crompton Greaves

D & J Dubai Toshiba HPGCL Siemens Limited TATA POWER

Reliance Industries Piramal Group

IDC Technology,Australia Jindal Power

NTPC Ltd. Avanta Power

RAY International, OMAN Reliance Power INDE, North America Plasma Research CII (Confedration of Indian Industries)

GSFC Ltd. Sarawak Energy 25 Jindal Steel Malaysia Kirloskar ltd. Contact Details Laxmi Associates

CORPORATE OFFICE: 13, 14, 15 ‘SUN ENCLAVE’ NEAR SUN CITY PARADISE, MANJALPUR, VADODARA GUJARAT – 390016 PHONE NO: +91-265-3267575 MOBILE NO: +91-9374076950 E-MAIL: [email protected] WEBSITE: www.laxmiassociates.in

THANKS