Medium Voltage Fuses Catalogue Ca132062en

Total Page:16

File Type:pdf, Size:1020Kb

Medium Voltage Fuses Catalogue Ca132062en Bussmann series Medium voltage fuse links catalogue SERIES Leadership in fusible circuit protection solutions Contact details Customer satisfaction team Online resources Eaton’s customer satisfaction team is available to answer Visit www.eaton.com/bussmannseries for the following questions regarding Eaton’s Bussmann series products. resources: Europe calls can be made between: • Product cross reference Monday — Friday 7.30 a.m. - 5.00 p.m. GMT • Product profiles • Online catalogues for the latest United States and European catalogues. The customer satisfaction team can be reached via: Phone: 00 44 (0) 1509 882 600 Application engineering Fax: 00 44 (0) 1509 882 786 Email: [email protected] Application engineering assistance is available to all customers. The application engineering team is staffed by university-qualifi ed electrical engineers who are www.my.eaton.com available with technical and application support. European calls can be made between: www.my.eaton.com supports the following product Monday — Thursday 8.30 a.m. - 4.30 p.m. GMT lines: B-Line series, Bussmann series, Crouse-Hinds Friday 8.30 a.m. - 4.00 p.m. GMT series, Lighting solutions, Cooper Power series and Wiring devices. Application engineering can be reached via: Get started today at www.my.eaton.com by clicking Phone: 00 44 (0) 1509 882 699 ‘Request User ID and Password’. Fax: 00 44 (0) 1509 882 794 • Easy to Navigate • Simple to Use General technical enquiries: [email protected] • Real-Time Data High speed technical enquiries: [email protected] 2 EATON’S BUSSMANN SERIES MEDIUM VOLTAGE FUSE LINKS CA132062EN—October 2017 www.eaton.com We make what matters work.* At Eaton, we believe that power is a fundamental part * of just about everything people do. That’s why we’re dedicated to helping our customers find new ways to manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. To improve people’s lives, the communities where we live and work, and the planet our future generations depend upon. Because this is what really matters. And we’re here to make sure it works. To learn more go to: Eaton.com/whatmatters We make what matters work. EATON’S BUSSMANN SERIES MEDIUM VOLTAGE FUSE LINKS CA132062EN—October 2017 www.eaton.com 3 Company overview Eaton is the leading source of fusible circuit protection solutions in the global marketplace. Eaton’s Bussmann series products are approved for use around the world and meet agency requirements and international standards: IEC, VDE, DIN, UL, CSA, BS and others. The headquarters for Eaton’s Bussmann series product line is located in Burton-on-the-Wolds, Leicestershire (UK) and is part of Eaton’s Industrial Control and Protection EMEA division. Eaton manufactures over 50,000 Bussmann series part numbers, covering extensive fusible circuit protection solutions for a wide range of applications: residential, industrial, motor protection, power conversion and distribution. Eaton has been a leading exponent in the design, development and manufacture of fuse links and their associated accessories for more than 100 years and has supplied fuse links to more than 90 countries worldwide. Eaton's team of specialist Engineers and Field Applications Engineers plays a leading role in international standardisation of fuse links offering comprehensive advice on selection and applications. With a continual commitment to meet our customers' needs with innovative high quality products with ISO 9001 'approval systems', Eaton is the supplier of choice for circuit protection solutions. 4 EATON’S BUSSMANN SERIES MEDIUM VOLTAGE FUSE LINKS CA132062EN—October 2017 www.eaton.com Table Contents Introduction to medium voltage fuse link technology. 6 How to order . 8 DIN Fuse links . 9 Motor fuse links . 23 Auxiliary transformer fuse links . 33 Oil fuse links . 53 British standard air fuse links . 61 US Style E-Rated fuse links . 73 Fuse clips . 91 Expulsion fuse links . 92 ASL - Automatic Sectionalising Links . 94 Boric acid fuse links . 98 Cross references . 105 DIN Fuse links . 105 Motor fuse links . 107 Voltage and auxiliary transformer fuse links . 107 Oil fuse links . 108 British standard air fuse links . 109 US Style E-Rated fuse links . 110 Boric acid fuse links . 115 Time current curves and cut-off curves list . 116 Index . 118 EATON’S BUSSMANN SERIES MEDIUM VOLTAGE FUSE LINKS CA132062EN—October 2017 www.eaton.com 5 Introduction to medium voltage fuse link technology Offering unparalleled short-circuit interruption capabilities, The main standard covering Medium voltage (MV) fuse links is Medium Voltage (MV) current-limiting fuse links are the IEC 60282-1, 2009. IEC defi nes MV as from 1 kV to 72.5 kV. principle protection device used by electrical utilities and switchgear manufacturers throughout the world. Current-limiting MV Fuse links, split into three internationally recognised types: back-up (or sometimes called partial range), Safe, reliable, environmentally friendly and cost effective, fuse links, which will interrupt any current from their rated MV Fuse links are the protection device of choice for Breaking capacity down to a Minimum breaking current, distribution circuits due to their speed of operation and specifi ed by the manufacturer. General purpose MV Fuse links current limiting ability in the event of a short-circuit fault. will interrupt all currents that will melt the elements within one hour. Full range MV Fuse links can interrupt any current below The diagram below shows the operation of a fuse link the rated Breaking capacity that melts the fuse elements interrupting a short-circuit fault, achieving a current zero well satisfactorily. within the fi rst half-cycle of a fault. Energy let-through into the site of a fault maybe typically only 1/500th of that of any other The diagram below illustrates the three performance criteria in type of switching device. terms of their Minimum breaking current I3. Medium Voltage electrical fuse link performance to IEC 60282-1 Back-Up RMS Zone of uncertain protection l2t amps Fuse Link Time in seconds General Purpose Zone of uncertain Peak amps Fuse Link protection l2 Full Range Fuse Link Current (amps) Minimum fusing Minimum Breaking current in free air Minimum Breaking Current (MBC) I 3 Typically 1.4 x I Current (MBC) Typically 1.1 x I N N Typically 3 x IN Minimum fusing Minimum Breaking current under Current (MBC) DERATED conditions Typically 1.8 x IN Current-limiting MV Fuse links are similar in construction to Low voltage (LV) cartridge types. Fuse elements do need to be much longer however to safely interrupt a medium voltage short-circuit. This is achieved by winding the elements round an internal core or holder, often called a star-core or spider; using this technique a one metre length element can be accommodated in a 250 mm length body. The elements are surrounded by a pure, highly compacted granular quartz fi ller. Like a LV fuse link, a MV Fuse link has a ceramic body. Most current-limiting MV Fuse links are also fi tted with a striker mechanism. This is used to operate the trip bar or mechanism in a fuse-switch combination, fuse-switch or ring main unit (RMU) to achieve low overload fault interruption and three-phase disconnection. The speed of operation reduces the effect of short-circuit Typically striker mechanisms are driven by a spring currents, dramatically limiting the energy delivered to the mechanism, triggered by a thin striker wire or striker coil faulted circuit, preventing the catastrophic results of high running the length of the fuse link, connected in parallel to faults and disturbing voltage arcs. The fuse link operation the fuse link elements. The striker coil is of much higher signifi cantly limits the arc-fl ash hazard at the fault location. resistance than the fuse link elements, so a current only fl ows Improved power supply quality also results from the use through the striker coil when the fuse link elements melt. The of fuse links. High fault currents are interrupted in a few current heats up the striker coil and this in turn melts the wire milliseconds, minimising voltage dips in system supply voltage. retaining the spring, releasing it and pushing out the striker. 6 EATON’S BUSSMANN SERIES MEDIUM VOLTAGE FUSE LINKS CA132062EN—October 2017 www.eaton.com Introduction to medium voltage fuse link technology Porcelain Porcelain barrel End cap barrel Striker coil Striker Granular quartz Striker coil Starcore Fuse elements Star core Weather seal Granular quartz Elements Non-current limiting Typically an Eaton’s Bussmann series MV Fuse link of a given rating may run 10-30oC cooler than comparable fuse links Essentially, non-current limiting fuse links have short elements which do not employ M-effect. This advantage is particularly and incorporate some means of lengthening the arc after the useful when the MV Fuse link is used in totally enclosed all element melts, extinguishing the arc and preventing re-ignition. insulated switchgear, such as cast resin fuse-switches or These are known as expulsion fuse links. compact SF6 insulated Ring Main Units (RMUs), or GIS HV switchgear, since less derating is required and hence a smaller Expulsion fuse links are an effective way of protecting rating of MV Fuse link will do the same job as a higher rated overhead distribution lines and transformers. They are MV Fuse link from another manufacturer. designed for outdoor use only and comprise a tin or copper fuse element in series with a fl exible braid in a tube. The tube In short M-effect fuse links are generally safer, give better forms one side of a triangle, with a latched connection at protection and are longer lasting than alternative designs, the top and a hinge at the bottom. The braid emerges from which do not employ these valuable features.
Recommended publications
  • Configuring UNIX-Specific Settings: Creating Symbolic Links : Snap
    Configuring UNIX-specific settings: Creating symbolic links Snap Creator Framework NetApp September 23, 2021 This PDF was generated from https://docs.netapp.com/us-en/snap-creator- framework/installation/task_creating_symbolic_links_for_domino_plug_in_on_linux_and_solaris_hosts.ht ml on September 23, 2021. Always check docs.netapp.com for the latest. Table of Contents Configuring UNIX-specific settings: Creating symbolic links . 1 Creating symbolic links for the Domino plug-in on Linux and Solaris hosts. 1 Creating symbolic links for the Domino plug-in on AIX hosts. 2 Configuring UNIX-specific settings: Creating symbolic links If you are going to install the Snap Creator Agent on a UNIX operating system (AIX, Linux, and Solaris), for the IBM Domino plug-in to work properly, three symbolic links (symlinks) must be created to link to Domino’s shared object files. Installation procedures vary slightly depending on the operating system. Refer to the appropriate procedure for your operating system. Domino does not support the HP-UX operating system. Creating symbolic links for the Domino plug-in on Linux and Solaris hosts You need to perform this procedure if you want to create symbolic links for the Domino plug-in on Linux and Solaris hosts. You should not copy and paste commands directly from this document; errors (such as incorrectly transferred characters caused by line breaks and hard returns) might result. Copy and paste the commands into a text editor, verify the commands, and then enter them in the CLI console. The paths provided in the following steps refer to the 32-bit systems; 64-bit systems must create simlinks to /usr/lib64 instead of /usr/lib.
    [Show full text]
  • Types and Programming Languages by Benjamin C
    < Free Open Study > . .Types and Programming Languages by Benjamin C. Pierce ISBN:0262162091 The MIT Press © 2002 (623 pages) This thorough type-systems reference examines theory, pragmatics, implementation, and more Table of Contents Types and Programming Languages Preface Chapter 1 - Introduction Chapter 2 - Mathematical Preliminaries Part I - Untyped Systems Chapter 3 - Untyped Arithmetic Expressions Chapter 4 - An ML Implementation of Arithmetic Expressions Chapter 5 - The Untyped Lambda-Calculus Chapter 6 - Nameless Representation of Terms Chapter 7 - An ML Implementation of the Lambda-Calculus Part II - Simple Types Chapter 8 - Typed Arithmetic Expressions Chapter 9 - Simply Typed Lambda-Calculus Chapter 10 - An ML Implementation of Simple Types Chapter 11 - Simple Extensions Chapter 12 - Normalization Chapter 13 - References Chapter 14 - Exceptions Part III - Subtyping Chapter 15 - Subtyping Chapter 16 - Metatheory of Subtyping Chapter 17 - An ML Implementation of Subtyping Chapter 18 - Case Study: Imperative Objects Chapter 19 - Case Study: Featherweight Java Part IV - Recursive Types Chapter 20 - Recursive Types Chapter 21 - Metatheory of Recursive Types Part V - Polymorphism Chapter 22 - Type Reconstruction Chapter 23 - Universal Types Chapter 24 - Existential Types Chapter 25 - An ML Implementation of System F Chapter 26 - Bounded Quantification Chapter 27 - Case Study: Imperative Objects, Redux Chapter 28 - Metatheory of Bounded Quantification Part VI - Higher-Order Systems Chapter 29 - Type Operators and Kinding Chapter 30 - Higher-Order Polymorphism Chapter 31 - Higher-Order Subtyping Chapter 32 - Case Study: Purely Functional Objects Part VII - Appendices Appendix A - Solutions to Selected Exercises Appendix B - Notational Conventions References Index List of Figures < Free Open Study > < Free Open Study > Back Cover A type system is a syntactic method for automatically checking the absence of certain erroneous behaviors by classifying program phrases according to the kinds of values they compute.
    [Show full text]
  • Cisco Telepresence ISDN Link API Reference Guide (IL1.1)
    Cisco TelePresence ISDN Link API Reference Guide Software version IL1.1 FEBRUARY 2013 CIS CO TELEPRESENCE ISDN LINK API REFERENCE guide D14953.02 ISDN Link API Referenec Guide IL1.1, February 2013. Copyright © 2013 Cisco Systems, Inc. All rights reserved. 1 Cisco TelePresence ISDN Link API Reference Guide ToC - HiddenWhat’s in this guide? Table of Contents text The top menu bar and the entries in the Table of Introduction ........................................................................... 4 Description of the xConfiguration commands ......................17 Contents are all hyperlinks, just click on them to go to the topic. About this guide ...................................................................... 5 Description of the xConfiguration commands ...................... 18 User documentation overview.............................................. 5 We recommend you visit our web site regularly for Technical specification ......................................................... 5 Description of the xCommand commands .......................... 44 updated versions of the user documentation. Support and software download .......................................... 5 Description of the xCommand commands ........................... 45 What’s new in this version ...................................................... 6 Go to:http://www.cisco.com/go/isdnlink-docs Description of the xStatus commands ................................ 48 Automatic pairing mode ....................................................... 6 Description of the
    [Show full text]
  • Technical Data Specifications & Capacities
    5669 (supersedes 5581)-0114-L9 1 Technical Data Specifications & Capacities Crawler Crane 300 Ton (272.16 metric ton) CAUTION: This material is supplied for reference use only. Operator must refer to in-cab Crane Rating Manual and Operator's Manual to determine allowable crane lifting capacities and assembly and operating procedures. Link‐Belt Cranes 348 HYLAB 5 5669 (supersedes 5581)-0114-L9 348 HYLAB 5 Link‐Belt Cranes 5669 (supersedes 5581)-0114-L9 Table Of Contents Upper Structure ............................................................................ 1 Frame .................................................................................... 1 Engine ................................................................................... 1 Hydraulic System .......................................................................... 1 Load Hoist Drums ......................................................................... 1 Optional Front-Mounted Third Hoist Drum................................................... 2 Boom Hoist Drum .......................................................................... 2 Boom Hoist System ........................................................................ 2 Swing System ............................................................................. 2 Counterweight ............................................................................ 2 Operator's Cab ............................................................................ 2 Rated Capacity Limiter System .............................................................
    [Show full text]
  • Unix/Linux Command Reference
    Unix/Linux Command Reference .com File Commands System Info ls – directory listing date – show the current date and time ls -al – formatted listing with hidden files cal – show this month's calendar cd dir - change directory to dir uptime – show current uptime cd – change to home w – display who is online pwd – show current directory whoami – who you are logged in as mkdir dir – create a directory dir finger user – display information about user rm file – delete file uname -a – show kernel information rm -r dir – delete directory dir cat /proc/cpuinfo – cpu information rm -f file – force remove file cat /proc/meminfo – memory information rm -rf dir – force remove directory dir * man command – show the manual for command cp file1 file2 – copy file1 to file2 df – show disk usage cp -r dir1 dir2 – copy dir1 to dir2; create dir2 if it du – show directory space usage doesn't exist free – show memory and swap usage mv file1 file2 – rename or move file1 to file2 whereis app – show possible locations of app if file2 is an existing directory, moves file1 into which app – show which app will be run by default directory file2 ln -s file link – create symbolic link link to file Compression touch file – create or update file tar cf file.tar files – create a tar named cat > file – places standard input into file file.tar containing files more file – output the contents of file tar xf file.tar – extract the files from file.tar head file – output the first 10 lines of file tar czf file.tar.gz files – create a tar with tail file – output the last 10 lines
    [Show full text]
  • Three-Phase Power Capacitor with Fuse Protection
    Power capacitors, LV CSB-F Three-phase power capacitor with fuse protection Description Features Features The application of new technologies to ma- Operating voltage 230, 400 V (for other voltages, please ask) nufacture prismatic capacitors have allowed Support voltage 400 V 440 V CIRCUTOR to reinvent the classic CS capa- Capacity tolerance ± 10% citor, manufactured for over 35 years. CS Capacitor + General protection fuses of the Unit composed of NH-00 type with high rupture power (HRP) The spirit of innovation and proprietary te- Insulation level 3 / 15 kV chnology used during the design of the new Discharge resistance 75 V / 3 minutes CSB capacitor have increased the lifespan of Overcurrent 1.3 times the rated current permanently traditional prismatic capacitors by over 60%. 10% 8 over 24 hours 15% up to 15 minutes over 24 hours Overvoltage This new series has improved all aspects of 20% up to 5 minutes over 24 hours the previous models, offering our customers 30% up to 1 minutes over 24 hours a longer-lasting, safer and more profitable Frequency 50 or 60 Hz • Dielectric < 0.2 W / kvar capacitor. Losses: • Total < 0.5 W / kvar • Dielectric regeneration • Internal fuse Protections • Overpressure system Application • Vermiculite Construction features • M6 for CV, M10 for CQ, CSB, Its application is mainly based on the com- • Power rating Terminals: CSB-6B, CFB, CFB-6B • Earth pensation of transformers and motors. In • M6 general, they are used for the compensation • CV 5 Nm Torque value of installations with constant loads. • CQ, CSB,
    [Show full text]
  • FSW Fuse-Switch-Disconnectors
    Motors | Automation | Energy | Transmission & Distribution | Coatings FSW Fuse-Switch-Disconnectors www.weg.net Fuse-Switch-Disconnectors The FSW Fuse-Switch-Disconnectors, developed according to International Standard IEC 60947-3 and bearing CE certification, are applied in electric circuits in general so as to provide the disconnection and protection against short circuits and overloads by means of NH blade contact fuses. In order to ensure a long lifespan, the FSW Fuse-Switch-Disconnectors are manufactured with reinforced thermoplastic materials and flame retardant. Additionaly, they feature contacts with silver coating, providing low power losses. Safety and Simplicity WEG switch-disconnector has several characteristics which aim at increasing security for operation and maintenance of the equipment, simplifying diagnoses and fuse replacement: g The switch-disconnector allows checking the state of the fuses through a transparent cover, besides featuring small openings which allow making electrical measurements without interrupting the operation. g As per IEC 60947-3, the switch-disconnector can perform the non- frequent opening under load. The FSW series has arc chambers for the extinction of the electric arc and disconnects all the phases together, ensuring full insulation between the load circuit and power supply. g In the opening of the switch-disconnector, the fuses remain fixed to the cover, preventing their drop or accidental contact between the energized parts. Furthermore, the cover is totally removable, allowing simple fuse replacement in a simple and safe area out of the electrical panel. g The switch-disconnectors also feature a built-in auxiliary contact in order to indicate when they are open or not properly closed.
    [Show full text]
  • AN-Mersen-Application-Information-Capacitor-Protection.Pdf
    CAPACITOR APPLICATION INFORMATION PROTECTION The primary responsibility of a capacitor fuse is to For applications 600V or less in lieu of specific fusing isolate a shorted capacitor before the capacitor can recommendations from the capacitor manufacturer, damage surrounding equipment or personnel. Typical we suggest a Mersen A60C Type 121 or an A6Y Type capacitor failure occurs when the dielectric in the 2SG fuse sized at 165% to 200% of the capacitor’s capacitor is no longer able to withstand the applied current rating (contact factory for technical data). If voltage. A low impedance current path results. The these fuses are not dimensionally acceptable, then excessive heat generated builds pressure and can a non-time delay Class J or Class RK1 fuse could be cause violent case rupture. A fuse will isolate the used and sized at 185% to 220% of the capacitor’s shorted capacitor before case rupture occurs. current rating. For applications over 600V to 5.5kV, we suggest FUSE PLACEMENT Amp-Trap A100C to A550C capacitor fuses. These The Code requires that an overcurrent device be medium voltage fuses are available in a variety of placed in each ungrounded conductor of each voltage ratings and mounting configurations. Refer capacitor bank (see Figure 1). The Code further to Section MV for specific data. Medium voltage requires that the rating or setting of the over- capacitor fuses are sized at 165% to 200% of the current device be as low as practicable. A separate capacitor current rating. overcurrent device is not required if the capacitor is Capacitor fuses are selected for their ability to connected on the load side of a motor-running provide short circuit protection and to ride through overcurrent device.
    [Show full text]
  • Hitachi Command Suite Dynamic Link Manager (For Windows®) User Guide
    Hitachi Command Suite Dynamic Link Manager (for Windows®) 8.6.4 User Guide This document describes how to use the Hitachi Dynamic Link Manager for Windows. The document is intended for storage administrators who use Hitachi Dynamic Link Manager to operate and manage storage systems. Administrators should have knowledge of Windows and its management functionality, storage system management functionality, cluster software functionality, and volume management software functionality. MK-92DLM129-45 April 2019 © 2014, 2019 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including copying and recording, or stored in a database or retrieval system for commercial purposes without the express written permission of Hitachi, Ltd., or Hitachi Vantara Corporation (collectively "Hitachi"). Licensee may make copies of the Materials provided that any such copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no other manner; or (ii) used for archival purposes. Licensee may not make any other copies of the Materials. "Materials" mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication. Some of the features described in the Materials might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Vantara Corporation at https://support.hitachivantara.com/en_us/contact-us.html.
    [Show full text]
  • UNIX/Linux Server – Red Hat 1
    EXEMPTION TEST INFORMATION FORM CIST 2432 – UNIX/Linux Server – Red Hat 1 A currently enrolled or accepted program student may receive course credit by passing the CIST 2432 exemption examination administered by the Gwinnett Technical College Assessment Center. The policy regarding Experiential Credit and Credit by Examination is in the College catalog. The examination must be completed prior to registration for the class for which the student is seeking credit by examination. Students may not request exemption tests for courses in which they have been enrolled nor may they take an exemption test more than once. The CIST 2432 exemption examination will cover these competencies: 1. UNIX/Linux Server Installation Process, Software Packages and Kernel Building 2. Manage Run Levels 3. UNIX/Linux Server Users and Groups 4. UNIX/Linux Server Security Permissions 5. UNIX/Linux Server File System 6. UNIX/Linux Server Memory and Process Management 7. UNIX/Linux Server System Log Files 8. UNIX/Linux Server Boot Process 9. UNIX/Linux Server System Configuration Files 10. UNIX/Linux Server File Backup and Restore 11. UNIX/Linux Server Compression 12. UNIX/Linux Server Fault Tolerance 13. UNIX/Linux Server Printing A student needs to score an 80% or higher on the CIST 2432 exemption examination to receive exemption credit. A student may want to review the below Red Hat textbook before taking the exemption exam: Product Name: Red Hat System Administration I Workbook (Guide) – English. Product Code: RH124-EN-SG-H. The Workbook uses a Product Code instead of an ISBN Number. In order to obtain your student guide, you must access the below link and create a Student account: https://www.gilmore.ca/redhat/registeruser.aspx?fcfca7159e743576c6d3a252fe1dfe1e.
    [Show full text]
  • SMD Power Inductors At-A-Glance Your One Source for Wire Wound Magnetic Solutions
    Worldwide Presence Engineering Expertise Leading Edge Technology Award Winning Support Our Commitment to Quality SMD Power Inductors At-A-Glance Your one source for wire wound magnetic solutions 2,700 Standard P/Ns to Choose From Inductance Range 0.01uH to 10mH DC Current Range 4mA to 70A DC Resistance Range 2mW to 140W Height Range 1mm to 12.3mm Custom Formulated Powder Materials High Efficiency +1 866.239.5777 signaltransformer.com MEDICAL Signal Transformer wire wound SMD Inductors have Diagnostic Surgical Equipment found their way into every market segment Patient Monitoring Hand Held Devices Surgical Generators In-Home Dialysis SC1206, SC1210, SC1812, SC2220 Series Blood Analyzers • 0.1uH to 10mH Inductance • 2mm to 5mm Height NETWORKING • 0.05A to 7.8A Saturation Current Data Center Switching Routers SC31 to SC108 SERIES — Unshielded Servers & Server I/O Server Blades • 0.8uH to 1.2mH Inductance 100G Core Switches • 1.8mm to 8.3mm Height NIC Cards • 0.03A to 4.7A Saturation Current 3U Top Rack & End of Rack 40G Firewall Patch Panels & Wiring SC33xxF SERIES — Unshielded Closet • 1.0uH to 1.0mH Inductance • 3mm to 11.43mm Height TELECOM/DATACOM • 0.1A to 18.0A Saturation Current Set-Top Boxes Hard Drives Laptops SC52LC & BC53LC Series — Shielded Printers • 1.2uH to 220uH Inductance Plotters • 2mm to 3.0mm Height Telephone Line Switching PBX • 0.18A to 2.92A Saturation Current Current Line Detection SCRH SERIES — Magnetically Shielded • 1.0uH to 180uH Inductance CONSUMER Digital Cameras • 1.9mm to 4mm Height Video Recorders • 0.15A
    [Show full text]
  • Principles of Shunt Capacitor Bank Application and Protection
    Principles of Shunt Capacitor Bank Application and Protection Satish Samineni, Casper Labuschagne, and Jeff Pope Schweitzer Engineering Laboratories, Inc. Presented at the 64th Annual Georgia Tech Protective Relaying Conference Atlanta, Georgia May 5–7, 2010 Previously presented at the 63rd Annual Conference for Protective Relay Engineers, March 2010, and 9th Annual Clemson University Power Systems Conference, March 2010 Originally presented at the 36th Annual Western Protective Relay Conference, October 2009 1 Principles of Shunt Capacitor Bank Application and Protection Satish Samineni, Casper Labuschagne, and Jeff Pope, Schweitzer Engineering Laboratories, Inc. Abstract—Shunt capacitor banks (SCBs) are used in the electrical industry for power factor correction and voltage support. Over the years, the purpose of SCBs has not changed, but as new dielectric materials came to market, the fusing practices for these banks changed from externally fused to internally fused, fuseless, and finally to unfused [1]. This paper gives a brief overview of the four most common types of SCBs. What are the differences between them? Which is the best one to use? What type of protection is best suited for each bank configuration? The paper provides a quick and simple way to calculate the out-of-balance voltages (voltage protection) or current (current protection) resulting from failed capacitor units or elements. While the identification of faulty capacitor units is easy with an externally fused bank, it is more complex with the other types of fusing, making maintenance and fault investigation difficult. This paper presents a novel method to identify the faulted phase and section in capacitor banks. Fig. 1. Four most common capacitor bank configurations I.
    [Show full text]