*THJ0423024* Page 1 of 7 Intertek Testing Services Taiwan Ltd
Total Page:16
File Type:pdf, Size:1020Kb
Test Report Number : TWNC00423024 Applicant: Formosa Plastics Corporation Date : Mar 19, 2015 Technical department plastics divison 100,Suei-Guan Road,Jen-Wu Hsiang, Kaohsiung County Sample Description: One (1) group of submitted samples said to be : Sample Description : M-81 Date Sample Received : Feb 05, 2015 Date Test Started : Feb 09, 2015 Test Conducted : As requested by the applicant, for details please refer to attached pages. Conclusion: Tested Sample Standard Result Submitted Samples Washington Chemicals of High Concern to Children (CHCC) See Test Content (as Contaminant) Conducted - As per Reporting Rule (Chapter 173-334 WAC) under Children's Safe Products Act (CSPA) - Chapter 70.240 (RCW) Remark: As per clause (1)(b) of Washington Adminstration Code (WAC) 173-334-080 of chapter 173-334 children's safe products -reporting rule, each chemical on the CHCC list that is a contaminant present in a product component must be reported at concentration above 100 ppm. The manufacturer must include the product component in the notice to the Washington state department of Ecology unless the manufacturer had in place a manufacturing control program and exercised due diligence to minimize the presence of the contaminant in the component. Authorized by: On Behalf of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0423024* Page 1 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Test Report Number : TWNC00423024 Test Conducted Washington Chemicals of High Concern to Children (CHCC) Content (as Contaminant) By Inductively Coupled Plasma-Optical Emission Spectrometer (ICP-OES), Gas Chromatography-Mass Spectrometer linked with Headspace (GC-MS linked with Headspace), Gas Chromatography-Mass Spectrometer (GC-MS), High Performance Liquid Chromatography-Photodiode Array Detector (HPLC-DAD), and Liquid Chromatography /Tandem Mass Spectrometer (LC-MS-MS) analysis. Result (ppm) Chemical CAS No. White powder Formaldehyde 50-00-0 ND Aniline 62-53-3 ND N-Nitrosodimethylamine 62-75-9 ND n-Butanol 71-36-3 ND Benzene 71-43-2 ND Vinyl Chloride 75-01-4 ND Acetaldehyde 75-07-0 ND Methylene Chloride 75-09-2 ND Carbon Disulfide 75-15-0 ND Methyl Ethyl Ketone 78-93-3 ND 1,1,2,2-Tetrachloroethane 79-34-5 ND Tetrabromobisphenol A 79-94-7 ND Bisphenol A 80-05-7 ND Diethyl Phthalate 84-66-2 ND Dibutyl Phthalate 84-74-2 ND Di-n-Hexyl Phthalate 84-75-3 ND Phthalic Anhydride 85-44-9 ND Butyl Benzyl Phthalate (BBP) 85-68-7 ND N-Nitrosodiphenylamine 86-30-6 ND Hexachlorobutadiene 87-68-3 ND Propyl Paraben 94-13-3 ND Butyl Paraben 94-26-8 ND 2-Aminotoluene 95-53-4 ND 2,4-Diaminotoluene 95-80-7 ND Methyl Paraben 99-76-3 ND p-Hydroxybenzoic Acid 99-96-7 ND Ethylbenzene 100-41-4 ND Styrene 100-42-5 ND 4-Nonylphenol;4-NP and its isomer mixtures 104-40-5 ND para-Chloroaniline 106-47-8 ND Acrylonitrile 107-13-1 ND Ethylene Glycol 107-21-1 ND Toluene 108-88-3 ND Phenol 108-95-2 ND 2-Methoxyethanol 109-86-4 ND *THJ0423024* Page 2 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Test Report Number : TWNC00423024 Test Conducted Result (ppm) Chemical CAS No. White powder Ethylene Glycol Monoethyl Ester 110-80-5 ND Tris(2-Chloroethyl) Phosphate 115-96-8 ND Di-2-Ethylhexyl Phthalate 117-81-7 ND Di-n-Octyl Phthalate (DNOP) 117-84-0 ND Hexachlorobenzene 118-74-1 ND 3,3'-Dimethylbenzidine and Dyes Metabolized to 3,3'- 119-93-7 ND Dimethylbenzidine Ethyl Paraben 120-47-8 ND 1,4-Dioxane 123-91-1 ND Perchloroethylene 127-18-4 ND Benzophenone-2(BP-2); 2,2',4,4'Tetrahydroxybenzophenone 131-55-5 ND 4-tert-Octylphenol; 1,1,3,3-Tetramethyl-4-Butylphenol 140-66-9 ND Estragole 140-67-0 ND 2-Ethylhexanoic Acid 149-57-5 ND Octamethylcyclotetrasiloxane 556-67-2 ND Pentachlorobenzene 608-93-5 ND C.I. Solvent Yellow 14 842-07-9 ND N-Methylpyrrolidone 872-50-4 ND 2,2',3,3',4,4',5,5',6,6'-Decabromodiphenyl Ether; BDE-209 1163-19-5 ND Perfluorooctanyl Sulphonic Acid and its Salts; PFOS 1763-23-1 ND 4-Octyl Phenol 1806-26-4 ND 2-Ethyl-Hexyl-4-Methoxycinnamate 5466-77-3 ND Mercury & Mercury Compounds 7439-97-6 ND Molybdenum & Molybdenum Compounds 7439-98-7 ND Antimony & Antimony Compounds 7440-36-0 ND Arsenic & Arsenic Compounds 7440-38-2 ND Cadmium & Cadmium Compounds 7440-43-9 ND Cobalt & Cobalt Compounds 7440-48-4 ND Butylated Hydroxyanisole; BHA 25013-16-5 ND Hexabromocyclododecane 25637-99-4 ND Diisodecyl Phthalate (DIDP) 26761-40-0 ND Diisononyl Phthalate (DINP) 28553-12-0 ND Tris(1,3-dichloro-2-propyl)phosphate (TDCPP)## 13674-87-8 ND Remarks : CHCC = Chemical Of High Concern To Children Reporting Limit = 50 mg/kg ppm = Parts per million = mg/kg ## = The first notice that manufacturers must provide to the Department of Ecology of Washing State that should be include the presence of TDCPP will be due Feb 28, 2015. *THJ0423024* Page 3 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Test Report Number : TWNC00423024 Test Conducted Measurement Flowchart: Sampling based on various test methodology For different material, digest Weigh sample and put Weigh sample and add Weigh sample and add the sample with appropriate sample into vial of organic solvent organic solvent acid headspace Make up with deionized Heat the headspace tray By solvent extraction By solvent extraction water Analyzed by ICP-MS Sampling the vapor from vial Concentrate the extract and Concentrate the extract and and injecting into GC-MS make up with organic make up with organic solvent solvent Further confirmation test Analyzed by GC-MS Analyzed by GC-MS Analyzed by HPLC-DAD/ LC-MS Refer to other methodology *THJ0423024* Page 4 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Test Report Number : TWNC00423024 Test Conducted End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0423024* Page 5 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Number : TWNC00423024 *THJ0423024* Page 6 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Number : TWNC00423024 *THJ0423024* Page 7 of 7 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 .