IBP1058 09 EFFECTS of PETROLEUM PROPERTIES on CUSTODY TRANFER MEASUREMENT Raymond J

Total Page:16

File Type:pdf, Size:1020Kb

IBP1058 09 EFFECTS of PETROLEUM PROPERTIES on CUSTODY TRANFER MEASUREMENT Raymond J IBP1058 09 EFFECTS OF PETROLEUM PROPERTIES ON CUSTODY TRANFER MEASUREMENT Raymond J. Kalivoda 1 Copyright 2009, Brazilian Petroleum, Gas and Biofuels Institute - IBP This Technical Paper was prepared for presentation at the Rio Pipeline Conference and Exposition 2009 , held between September, 22-24, 2009, in Rio de Janeiro. This Technical Paper was selected for presentation by the Technical Committee of the event according to the information contained in the abstract submitted by the author(s). The contents of the Technical Paper, as presented, were not reviewed by IBP. The organizers are not supposed to translate or correct the submitted papers. The material as it is presented, does not necessarily represent Brazilian Petroleum, Gas and Biofuels Institute" opinion, or that of its Members or Representatives. Authors consent to the publication of this Technical Paper in the Rio Pipeline Conference Proceedings. Abstract Petroleum products bought and sold on the world wide market may be transported over thousands of miles and change ownership many times from the well head to the end user. Each time the product changes ownership, a “custody transfer” is completed and both buyer and seller expect their asset share to be accurately measured. The dynamic measurement provided by meters is a convenient and accurate means to measure valuable petroleum products. Selecting the right meter for the job with a high level of confidence is imperative to ensure accurate measurement at the lowest cost of ownership. The fluid properties of petroleum products varies widely from low viscosity refined products like LPG, gasoline, diesel and jet fuel to high crude oils with a high concentration of contaminants such as sediment & water (S&W) and entrained gas. Understanding the fluid properties of both refined produces and crude oils and how they affect the different metering technologies is important in selecting the right meter for a specific application. This paper will define the fluid properties of both refined products and crude oils, explain their effect on the different custody transfer metering technologies and evaluate these technologies for the accurate measurement of petroleum products. 1. Introduction Refined products are normally well defined and not highly viscous. Crude oils can vary widely in viscosity and quality. They can have a viscosity similar to refined products or be highly viscous. The demand of heavy or high viscous crude oil is increasing due to the price and availability. This trend is expected to accelerate with increasing demand for petroleum products due to the expansion of the world economies and the reduction in light low viscosity crude oil reserves. As a result of this trend crude oil transporters, pipeline and marine, are gearing up to handle a wider range of heavy crude oils. The accurate measurement of high viscosity crude presents new challenges, though. Each of these applications is different and no one type of meter is best for all applications. Fortunately we have a wide range of metering technologies to address low, medium and high viscosity applications: • Positive Displacement Meters, known for their highly accurate measurement of high viscosity products. • Convention Turbine Meters are suitable for most refined products and light to medium viscosity crude oils. • Helical Turbine Meters can handle light to higher viscosity crude oils and with special viscosity compensation software; the viscosity range can be increased to handle high viscosity crude oils. • Coriolis Mass Meters are especially suited for low flow applications over a wide variety of viscosities. 1 Petroleum Measurement Manager - EMC MEASUREMENT SOLUTIONS Rio Pipeline Conference and Exposition 2009 • Liquid Ultrasonic Meters can handle low and medium viscosity products and are gaining wider application experience and acceptance on more viscous products. Knowing the strengths and weaknesses of each of these technologies is important in making the best decision for a given application. 2. Viscosity Characteristics of Petroleum Products Viscosity can be expressed in many different units but for our purposes kinematic viscosity is the most suitable. The most commonly used viscosity units in the petroleum industry are: • Kinematic Viscosity - centistokes (cSt) - The base unit is a Stoke but as the value of Kinematic Viscosity is normally small, the unit is often converted by multiplying by 100, centistokes (cSt). In the metric system the kinematic viscosity unit is cm2/s (centimeter2/second). • Saybolt Universal Viscosity (SSU) - SSU can be converted to cSt using a conversion table. • Dynamic Viscosity centipoise (cP) - The base unit is Poise but like kinematic viscosity, the Poise is often multiplied by 100, centipoise (cP). Centipoise can be converted to centistokes by dividing by the specific gravity, (cSt = cP / SG). In the metric system, the dynamic viscosity unit is Pa^s (Pascal^second). Crude oils are normally defined by their API gravity, which is sometimes confused with the product ’s viscosity. API gravity is defined as the density of crude oil at a specific temperature compared to the density of water at a standard temperature, 60°F. The relationship between specific gravity (SG) and API gravity is: SG (60°F/60°F) = 141.5 / (131.5 + API). Tables 1 and 2 show refined products and crude oil characteristics, respectively. The API gravity and specific gravity are stated at reference temperature. The viscosity is also related to temperature and decreases as temperature increases. As seen in these tables the effect temperature has on viscosity is notably more significant on heavy refined and crude oils then on lighter products and crude oils. This is an import factor in the proper selection of a particular metering technology for many heavy and medium oil applications. Table 1. Refined Products Characteristics Gravity @ 60°F (15°C) Viscosity (cSt) Product £2 Specific API 30 (-1) 60 (15) 150 (66) Propane - LPG 0.51 146 0.3 0.2 0.2 0.2 Gasoline 0.77 52 1.0 0.8 0.7 0.5 Jet Fuel 0.81 43 3.5 2.6 2.0 1.1 Kerosene 0.84 37 3.7 2.7 2.1 1.2 Fuel Oil 3 (max) 0.92 22 - 11 5.7 3.5 Fuel Oil 6 (min) 1.00 10 - 828 155 46 Table 2. Crude Oil Characteristics Gravity @ 60°F (15°C) Viscosity (cSt) Crude Type Specific API 60°F (15°C) 100°F (38°C) 150°F (66°C) 0.79 48 3 2 1 Light 0.86 32.6 21 9 5 Medium 0.90 25.3 1442 243 93 0.95 17.8 2040* 340 130* Heavy 0.96 16.2 3440* 574 230* 1.00 10 5100* 1294 520* * estimated 2 Rio Pipeline Conference and Exposition 2009 3. Meter Selection Selecting the correct meter for a specific measurement task is dependant on the following operating conditions: System Characteristics - Pressure and temperature are typically specified but other characteristics such as pulsating flow from a PD pump or valve operation / location should also be considered as they may cause measurement errors for some types of meters. Product Characteristics - The basic product characteristics of viscosity, specific or API gravity, chemical characteristics and lubricating quality must be specified. Also, any contaminates such as particulates, air or water contained in the product must be identified and noted in an application analysis. Flow Range - This is the minimum and maximum flow rate over which the meter will operate. The flow range can also be expressed as the “turndown range”, which is the ratio of the maximum to the minimum flow rate (e.g., a flow range of 10 bph to 100 bph is a 10:1 turndown range). Viscosity Range - Just as the flow range can be expressed as a turndown range, so can the maximum to the minimum viscosity be expressed as a turndown range. Accuracy - The Accuracy of a liquid flow meter depends predominantly on the flow range and the viscosity range of the products over which the meter operates. The following formula relates Flow Turndown Range to Viscosity Turndown Range to yield a Measurement Turndown Range (MTR). Comparing the MTR of various meter types for specific operating conditions provides a guide to selecting the meter with the best potential accuracy for the application. Measurement Turndown Range = Flow Turndown Range x Viscosity Turndown Range or MTR = FTR x VTR 4. Types of Dynamic Flow Meters Dynamic fluid flow meters can be classified as either direct volumetric meters or inference type meters. A Positive Displacement (PD) meter (Figure 1) directly measures volumetric flow by continuously separating (isolating) the flow stream into discrete volumetric segments. Inference meters determine volumetric flow rate by measuring some dynamic property of the flow stream. Turbine meters, both conventional and helical types, fall in the latter category along with Coriolis mass meters and ultrasonic meters. PD Meters PD meters are highly versatile and have been used for custody transfer petroleum applications since their introduction in the 1930’s. Because of their high accuracy, stability, reliability, mechanical output and ease of proving, they are still widely used in the petroleum industry. Other meter technologies have displaced PD meters for high volume, low viscosity applications like refined product or light crude oil pipelines. PD meters still have measuring advantages for medium to high viscosity products. PD meters are one of the few meters that have highly stable meter factors on medium to high viscosity products. Figure 1. PD Meter Cutaway PD Meter Operating Principle PD meters measure flow by momentarily isolating segments of known volume and counting them. For example in a rotating vane PD meter, as the rotor turns, isolated chambers are formed between blades, rotor, base, cover and housing. Like a revolving door, known segments of fluid pass through the measurement chamber and are counted. 3 Rio Pipeline Conference and Exposition 2009 All PD meters have moving and stationary parts which require clearances between them.
Recommended publications
  • Magellan Pipeline Company,L.P
    R.C.T. XXX MAGELLAN PIPELINE COMPANY,L.P. LOCAL PIPELINE TARIFF CONTAINING RULES AND REGULATIONS GOVERNING THE TRANSPORTATION AND HANDLING OF CRUDE PETROLEUM TRANSPORTED BY PIPELINE The rate published in this tariff is for the interstate transportation of Crude Petroleum by pipeline, subject to the regulations named herein. Rate is payable in U.S. currency. The matter published herein will have no adverse effect on the quality of the human environment. EFFECTIVE: XXX, 2010 Issued & Compiled By: Tina R. Granger, Pipeline Tariffs MAGELLAN PIPELINE COMPANY, L.P. One Williams Center Tulsa, Oklahoma 74172 (918) 574-7415 SECTION I Rules and Regulations of Railroad Commission of Texas Rule §3.71, Pipeline Tariffs 1. ALL MARKETABLE OIL TO BE RECEIVED FOR TRANSPORATION By the term “marketable oil” is meant any crude petroleum adapted for refining or fuel purposes, properly settled and containing not more than two percent (2.0%) of basic sediment, water, or other impurities above a point six (6) inches below the pipeline connection with the tank. Pipelines shall receive for transportation all such “marketable oil” tendered; but no pipeline shall be required to receive for shipment from any one person an amount exceeding three thousand (3,000) barrels of petroleum in any one day; and, if the oil tendered for transportation differs materially in character from that usually produced in the field and being transported there from by the pipeline, then it shall be transported under such terms as the shipper and the owner of the pipeline may agree or the commission may require. 2. BASIC SEDIMENT, HOW DETERMINED – TEMPERATURE In determining the amount of sediment, water or other impurities, a pipeline is authorized to make a test of the oil offered for transportation from an average sample from each such tank, by the use of centrifugal machine, or by the use of any other appliance agreed upon by the pipeline and the shipper.
    [Show full text]
  • Oil & Gas Custody Transfer
    Process Solutions Guide Oil & Gas Custody Transfer Crude Oil Crude Oil Natural Gas Distribution Natural Gas Liquids Refined Products Crude Oil is the first unit in this four-step overview of the Custody Transfer process Overview of Crude Oil Process Some 80 million barrels of oil per day is typically transported from producing oilfields around the world. Trucks, trains and pipelines are utilized to move oil over land to high capacity storage terminals, refinery facilities or exportation ports. Tankers ship the majority of the world's internationally traded crude oil from producing to consuming nations. Small diameter ‘gathering’ pipelines (approximately 2-8 inches in diameter) collect crude oil from different oil production facilities into central storage facilities or into ‘trunk’ lines (generally 8-24 inch diameter) which move oil in bulk over great distances. Crude oil may be stored in tanks at a storage terminal to better manage changes in supply and demand. A storage terminal may also have truck and rail car off-loading facilities to support other means of oil gathering transportation. Crude oil pipeline companies are generally separate from the producing/receiving companies and only provide transportation services for crude oils that vary widely in density, viscosity, sulfur content, and in other fluid properties. As such, pipeline operations regulate the amount of water and sulfur that can be transported and end-users strictly specify by contract the oil quality that they are purchasing. Computer-aided automation systems - located in central control rooms - monitor rates of flow, pressures and fluid characteristics to quickly detect possible pipeline leaks and to control pipeline valves and pumps to ensure contractual demands are met.
    [Show full text]
  • LNG CUSTODY TRANSFER HANDBOOK 5Th Edition: 2017 GIIGNL Document Status and Purpose
    LNG CUSTODY TRANSFER HANDBOOK 5th Edition: 2017 GIIGNL Document status and purpose This fifth (2017) edition of the GIIGNL LNG transfer and LNG transfer from an onshore This latest version replaces all previous editions Custody Transfer Handbook reflects GIIGNL’s terminal to small scale LNG carriers. More than of the custody transfer handbook. Please always understanding of best current practice at the pointing at the differences and highlighting the consult the GIIGNL website www.giignl.org to time of publication. points of attention when dealing with these new check for the latest version of this handbook, operations, this fifth version provides answers esp. when referring to a pdf download or a The purpose of this handbook is to serve as a and solutions for setting up (slightly) altered or printout of this handbook reference manual to assist readers to new custody transfer procedures. As a reminder, understand the procedures and equipment (Photo front cover : © Fluxys Belgium – P. Henderyckx) it is not specifically intended to work out available to and used by the members of GIIGNL procedures for overland LNG custody transfer to determine the energy quantity of LNG operations involving LNG trucks, containers or transferred between LNG ships and LNG trains, or for small scale LNG transfer such as terminals. It is neither a standard nor a bunkering or refueling of ships and trucks. For specification. these, kind reference is made to the GIIGNL This handbook is not intended to provide the Retail LNG / LNG as a fuel handbook. reader with a detailed LNG ship-shore custody No proprietary procedure, nor particular transfer procedure as such, but sets out the manufacture of equipment, is recommended or practical issues and requirements to guide and implied suitable for any specific purpose in this facilitate a skilled operator team to work out a handbook.
    [Show full text]
  • Custody Transfer Metering
    flotek.g 2017- “Innovative Solutions in Flow Measurement and Control - Oil, Water and Gas” August 28-30, 2017, FCRI, Palakkad, Kerala, India CUSTODY TRANSFER METERING Pranali Salunke Mahanagar Gas Ltd. Email: [email protected] Mobile: +91 9167910584 Mumbai, India custody transfer. A flow prover can be ABSTRACT installed in a custody transfer system While performing a flow measurement in a to provide the most accurate process control, the accuracy of measurement possible. measurement is typically not as important as the repeatability of the measurement. When There have been large changes in the controlling a process, engineers can tolerate instrumentation and related systems some inaccuracy in flow measurement as used for custody transfer. Meters with long as the inaccuracy is consistent and intelligence i.e. with modern repeatable. In some measurement electronics, software, firmware and applications, however, accuracy is an connectivity can perform diagnostics extremely important quality, and this is and communicate information, particularly true for custody transfer. The alarms, process variables digitally. money paid is a function of the quantity of fluid transferred from one party to another. Small KEY WORDS error in the metering can add up to big losses Custody Transfer, Ultrasonic flow in terms of money. meter, Coriolis meter, Standards, proving Until now, five technologies are used when it comes to custody transfer metering: 1.0 INRODUCTION 1. Differential Pressure (DP) flow meters Custody Transfer in oil and gas 2. Turbine meters industry refers to the transactions 3. Positive displacement meters involving transporting physical 4. Coriolis meters substance from one party to another. 5. Ultrasonic meters The term "fiscal metering" is often Many aspects are taken into consideration interchanged with custody transfer, when a flow meter is to be selected for and refers to metering that is a point of custody transfer metering.
    [Show full text]
  • The Basics of Gas Ultrasonic Flow Meters for Custody Transfer
    BASICS OF ULTRASONIC FLOW METERS David Crandall Flow Solutions Sales Manager Cameron Measurement Systems 1000 McClaren Woods Drive Coraopolis, PA 15108 Introduction The purpose of this paper is to explain the measurement of natural gas for custody transfer applications through the use of ultrasonic meters. Specifically, this paper explains the operation of ultrasonic meters, issues surrounding their performance in natural gas, calibration procedures, and proper installation considerations. Additionally, the electronics making the measurements generate calculated values relating to the operation of the meter and as a result a database is available to provide analysis of the meter’s ongoing performance. Meter health parameters can be evaluated to verify the meter’s operation and these principles are explained. Background The ultrasonic meter measures and calculates volumetric flow by summing weighted fluid velocities across the meter diameter. Piezo electric transducers are mounted on opposite sides of the meter to form one or more measuring paths and these measuring paths provide the average fluid velocity. The volumetric flow calculation is the fluid velocity of each path times the cross sectional area. The conversion of individual path velocities into volumetric flow is performed through the use of Gaussian integration techniques. Both liquids and gases are measured using ultrasonic flow meters. The reasons most frequently cited for implementing ultrasonic flow meters are: Low Pressure Loss – Ultrasonic meters have no moving parts and the pressure losses are typically equal to the length of equivalent pipe. High flow rates - An ultrasonic meter handles exceptionally high flow rates with a single meter. There are installations of ultrasonic meters with meter diameters of 30 inches.
    [Show full text]
  • 43 CFR 3174 – Measurement Of
    § 3174.1 43 CFR Ch. II (10–1–17 Edition) Subpart 3174—Measurement of conditions where a series of meter fac- Oil tors have been determined over a range of normal operating conditions. Event log means an electronic record SOURCE: 81 FR 81504, Nov. 17, 2016, unless otherwise noted. of all exceptions and changes to the flow parameters contained within the § 3174.1 Definitions and acronyms. configuration log that occur and have (a) As used in this subpart, the term: an impact on a quantity transaction Barrel (bbl) means 42 standard United record. States gallons. Gross standard volume means a vol- Base pressure means 14.696 pounds per ume of oil corrected to base pressure square inch, absolute (psia). and temperature. Base temperature means 60 °F. Indicated volume means the uncor- Certificate of calibration means a docu- rected volume indicated by the meter ment stating the base prover volume in a lease automatic custody transfer and other physical data required for system or the Coriolis meter in a CMS. the calibration of flow meters. For a positive displacement meter, the Composite meter factor means a meter indicated volume is represented by the factor corrected from normal operating non-resettable totalizer on the meter pressure to base pressure. The com- head. For Coriolis meters, the indi- posite meter factor is determined by cated volume is the uncorrected (with- proving operations where the pressure out the meter factor) mass of liquid di- is considered constant during the vided by the density. measurement period between provings. Innage gauging means the level of a Configuration log means the list of liquid in a tank measured from the constant flow parameters, calculation datum plate or tank bottom to the sur- methods, alarm set points, and other face of the liquid.
    [Show full text]
  • FLOWSIC600 Ultrasonic Gas Flow Meter
    DATA SHEET FLOWSIC600 Ultrasonic Gas Flow Meter For Custody Transfer and Process Applications The Technology Leader in Gas Ultrasonic Metering FLOWSIC600 For Custody Transfer and Process Applications Many years of experience and continuous improvement of the The FLOWSIC600 uses the proven 4-path Westinghouse® measuring technique have led to a new generation of ultrasonic chordal configuration for superior performance, even in the most gas flow meters – the FLOWSIC600. This compact design utilizes adverse piping conditions. This design is used for all 4-path a patented concealed transducer cabling system which provides meters 3” and larger. additional meter integrity and low maintenance even in the harshest industrial conditions. The FLOWSIC600 has provisions for analog, frequency and digital outputs plus two Modbus serial ports. This permits easy The FLOWSIC600 can be equipped with 1, 2, 4, 5 or 8 non-re- interface with all brands of flow computers. An integrated LCD flective, chordal measuring paths. This makes it ideal for display provides local access to all live data and alerts the user applications ranging from high accuracy custody transfer to of any past or present alarms without necessitating the use of a those with less precise requirements such as flare and under- computer. Extremely low power consumption (less than 1 watt) ground storage. permits operation with solar power for remote applications. FLOWSIC600 – Key Benefits at a Glance FLOWSIC600 – Applications at a Glance • Integrated realtime health monitoring with user programmable
    [Show full text]
  • Gas / Natural Gas /CNG/ Custody Transfer As Per ISO , AGA , Etc
    Course on Gas / Natural Gas /CNG/ Custody Transfer as per ISO , AGA , etc., 203 in series Course Organised by: FLUID CONTROL RESEARCH INSTITUTE ISO 9 , (ISO 9001: 2008 Certified, NABL accredited organisation) ( , (Ministry of Heavy Industries & Public Enterprises, Govt. of India) , - , Kanjikode West, Palakkad – 678 623, Kerala. Tel: +91-491-2566120, 2566206, 2566119, 2569010, Fax: +91-491-2566326 FCRI, a state of the art flow and fluid engineering facility, first of its kind in South East Asia is dedicated to Research & Development in Fluid Flow Measurement & Control Techniques. About 100 sponsored Projects for various reputed organisations have been successfully completed by the Institute. The Institute provides facilities towards technological developments to the flow product industries and serves as a National Certifying Authority and Quality / reliability evaluation facility. The Institute also provides facility for calibration of mechanical, thermal, electrical parameters, noise, vibration etc. Apart from testing and calibration, the Institute conducts National and International training programmes in the field of flow control, measurement & Instrumentation, Calibration and related areas. Laboratory Fluid flow Maximum Flow Rate Maximum Uncertainty in Flow Rate Uncertainty in Volume NABL C026/T027 (m3/h) Line Size (% reading) (% reading) Upto 200m³/h : ±0.05% 4500 900mm 200 to 2500m³/h : ±0.10% Water Flow 2m3-20m3 : ± 0.05% 15000 2000mm 2500 to 4500 m³/h : ±0.15% 5000-15000m³/h : ±0.5% 0.016 m³/hr to 0.25m³/hr : ±0.3% Air Flow 0.25
    [Show full text]
  • Accurate Measurement Guidelines
    Accurate Measurement Section I Chapter 2 Guidelines Revision: 1 Introduction This standard is designed to provide production operations personnel with detail information concerning Fieldwood's Measurement Standard Operating Procedures. Included are the following: • Meter Proving Guidelines • Measurement Principles • S&W, Gravity & Temperature • Orifice Plate Holder & Calibration • Custody Transfer Measurement • Meters & Meter Proving • Sampling Procedures • Witnessing Responsibilities Meter Proving & Calibration The purpose of Meter Proving/Meter Calibration is to obtain accurate results so Fieldwood Energy will receive appropriate income for the measured volumes and report correct data/volumes on the morning reports (i.e. Accurate Measurement). The reason meters are proven and calibrated is: • So all parties are treated fairly • It's a tool for troubleshooting • To report exceptions on Morning Reports • Uniformity in Measurement Equipment and Procedures • Fixed Methods for Problem Solving • Repeatable Procedures and Practices Data Retention and Recordkeeping Here are the data retention and recordkeeping requirements: • Well Test Documentation = 2 Years on Platform • Gas & Oil Meter Proving & Run Tickets = 2 Years on Platform • Chart and/or EFM (Electronic Flow Measurement) Data = 2 Years on Platform Note: All inquiries by BSEE for production audit information should be directed to Safety Environmental and Compliance Department. Safe Work Practices Page I-2-1 Accurate Measurement Section I Chapter 2 Guidelines Revision: 1 Gas Measurement Daily gas volumes will be obtained from the Pipeline Gas Sales Meter and note readings on the morning report. All gas FMP points will have a gas sample procured and a gas analysis performed every six (6) months. Copies of the gas analysis will be kept in the gas measurement file on the platform for 2 years.
    [Show full text]
  • Custody Transfer Flow Measurement with New Technologies
    CUSTODY TRANSFER FLOW MEASUREMENT WITH NEW TECHNOLOGIES Stephen A. Ifft McCrometer Inc. Hemet, California, USA ABSTRACT New technologies can often bring advances to the operational processes within many industries. These advances can improve the overall production of a facility with better performance, better reliability, and lower costs. Obstacles exist, however, to the introduction and use of these new technologies. The natural gas industry has such obstacles, particularly with the use of new technology for custody transfer flow measurement. Paper standards from international organizations like the International Organization for Standardization, the American Petroleum Institute and the American Gas Association are examples of these obstacles. While these paper standards serve to protect and guide companies in their use of technology, they prevent the introduction of new and often better technology. A reform is underway in the natural gas industry to allow companies to take advantage of newer technologies that were not accessible before. This will hopefully redefine the phrase “approved for custody transfer measurement.” This phrase has been used incorrectly around the world for decades since none of the organizations listed above actually approve meters for custody transfer measurement. If companies are to reap the benefits of newer and better technology, the industry must continue to reform the existing paper standards that exclude every technology but those that are decades old. As new technologies become available, the industry must have procedures ready for evaluating their possible benefits and detriments. Without these procedures, the advances of the modern world will be overlooked. McCrometer Inc. is a manufacturer of flow measurement devices, including the V-Cone differential pressure flowmeter.
    [Show full text]
  • Control Techniques Guidelines for the Oil and Natural Gas Industry 2016
    Control Techniques Guidelines for the Oil and Natural Gas Industry [Page intentionally left blank] ii EPA-453/B-16-001 October 2016 Control Techniques Guidelines for the Oil and Natural Gas Industry U.S. Environmental Protection Agency Office of Air and Radiation Office of Air Quality Planning and Standards Sector Policies and Programs Division Research Triangle Park, North Carolina iii DISCLAIMER This report has been reviewed by EPA’s Office of Air Quality Planning and Standards and has been approved for publication. Mention of trade names or commercial products is not intended to constitute endorsement or recommendation for use. iv TABLE OF CONTENTS TABLE OF CONTENTS .................................................................................................................v 1.0 INTRODUCTION .............................................................................................................. 1-1 2.0 BACKGROUND AND OVERVIEW ................................................................................ 2-1 2.1 History of New Source Performance Standards that Regulate Emission Sources in the Oil and Natural Gas Industry .......................................................................................... 2-1 2.2 State and Local Regulations ........................................................................................... 2-2 2.3 Development of this CTG .............................................................................................. 2-4 3.0 OVERVIEW OF THE OIL AND NATURAL GAS INDUSTRY AND SOURCES
    [Show full text]
  • Upstream Natural Gas Sales Verification Producer and Pipeline Perspectives
    Upstream Natural Gas Sales Verification Producer and Pipeline Perspectives Mark B. Fillman, Chief Operating Officer & Jayson A. Payne, iMeasurement Manager The Coastal Flow Measurement Companies P.O. Box 58965 Houston, TX 77258-8965 Introduction the pipeline’s measurement calculations is a com- mon, prudent, and highly recommended practice. Within the upstream sector of the oil and gas indus- As will be reviewed in more detail below, both par- try, the custody transfer of natural gas is usually de- ties have separate yet essential responsibilities termined by orifice measurement which is governed relating to the verification of accurate and account- by a sales agreement between the producer and able natural gas sales. pipeline company. In most cases, the gas sales agreement references a combination of American Key Considerations Gas Association (AGA), American Petroleum Insti- tute (API), and Gas Processors Association (GPA) One of the greatest challenges for the pipeline standards which are to be incorporated into the cus- company is to maintain an acceptably minimal tody measurement procedures. Verification that the “Lost and Un-Accounted For” (LUAF) between its physical deliveries of natural gas are accurate and inlets and outlets. As a general rule, pipelines accountable, for both parties, is fundamental to the strive to maintain the LUAF at less than 1% on an business cycle that occurs each month. This paper Mcf and MMBtu basis after accounting for shrink- reviews the relationships between producer and age and fuel. Symbolically, LUAF is the pipeline’s pipeline, the varying responsibilities of each party, blood pressure, measurement is the heartbeat. and some useful methods to produce more accurate Excessive differences (positive or negative) result- and accountable natural gas measurement results.