801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: [email protected] INSTALLATION INSTRUCTIONS 55 SERIES ELECTRIC STRIKE

55-ABC Universal Strike Pak for 55-A for cylindrical 55-B / 55-C For mortise 55-D / 55-E / 55-F for mortise multiple cylindrical and mortise Grade 1 or equivalent. locksets with up to a 3/4" locksets with latch and deadbolt applications. INSTALLATION SDC 55 Series heavy duty electric strikes are designed 1. Verify lock compatibility, refer to page 2 and Fig. 6, page 4. for use with cylindrical and mortise locksets and mortise 2. For proper frame preparation, refer to template drawings, exit devices. Several faceplate configurations eliminate Fig. 4 & 5, page 4. the need for centerline relocation, making them perfect 2. Factory supplied in Failsecure mode. For Failsafe mode refer for new or retrofit construction. to Fig. 2, page 3 3. Determine minimum wire gauge required. See wire gauge chart below. FEATURES: 4. CAUTION! Before connecting power wires check for proper operating Non-handed voltage at opening with a volt meter. Voltage must be within +/- 10% No Centerline relocation of strike operating voltage for proper operation. Up to 3/4” latch and 1” deadbolt 5. Configure strike for 12 or 24VDC operation. Refer to pigtail power 1/8”Horizontal alignment adjustment connector wiring in Fig. 1, Page 3. Connect wires to power source. Field selectable Fail-Safe/Fail-Secure 6. To install the strike into the frame opening: Field selectable 12/24VDC A) Position the wiring either down or up or toward the back of the Stainless steel, corrosion resistant hollow metal frame. Make sure wires are completely clear of strike, Tamper resistant heavy duty construction so they are not pinched when mounting strike in the frame. Plug-in connector B) Insert mounting screws through the faceplate and secure into Fits ANSI 115.1 frame prep. with face modification mounting tabs. 7. After installation check horizontal alignment. There should be 1/32” Patent pending allowable movement when the is pulled toward the keeper. 8. ALIGNMENT ADJUSTMENT: Loosen mounting screws, shift strike body behind faceplate horizontally as shown in Fig. 3A, page 3, OPTIONAL MONITORING OUTPUTS: then tighten mounting screws. LCM (Keeper Deadlocked Monitor) 9. For excessive horizontal alignment issues, remove shim filer bar from Signals keeper is closed and deadlocked and/or unlocked. the keeper as shown in Fig. 3B, page 3 LBM (Latch Bolt Monitor) 10. The Electric Door Strike MUST be installed in such a way and in such a Signals latch is extended into strike and/or retracted. location so as not to impair the operation of an emergency exit or panic DBM (Deadbolt Monitor) hardware mounted on the door. Signals deadbolt is extended into strike and /or retracted. Strike Input - Minimum Wire Gauge Requirements

Warnock Hersey Tested according to: Voltage 100 ft 150 ft 200 ft 250 ft 300 ft UL 10C, 3 Hr Fire Rated (Fail-Secure only). 12VDC 18 Ga 16 Ga 14 Ga 14 Ga --- UL Tested according to: UL 1034 Burglary-Resistant 24VDC 18 Ga 18 Ga 18 Ga 16 Ga 16 Ga Monitoring outputs: Minimum 22 Gage wire recommended

OPERATION: Fail-Secure (Power-to-Unlock): Unlocked when energized. Fail-Safe (Power-to-Lock): Locked when energized. Unlocked Locked when de-energized and during power failure. when de-energized and during power failure. Application: For non fire rated and fire rated (exception, Application: Non-fire rated doors only. may not be used on stairwell doors). May not be maintained in CAUTION: Fail-safe is not permitted with the UL Fire Door the unlocked (energized) state when used with fire rated doors. Accessory label.

P:\INSTALLATION INST\ELECTRIC STRIKES\INST-55\INST-55.vsd REV F 02-19 Page 1 55 SERIES ELECTRIC STRIKE UNIVERSAL APPLICATION KITS Strike body and faceplate(s) provided as shown below. Order strike bodies and different faceplates separately Faceplates are interchangeable and may be ordered separately. to accommodate all applications.

Model Lockset Application Compatible Locks Operation

55-ABC Universal Strike Pak • Adaptable to all 55-A, 55-B, 55C • Grade 1 or equivalent applications listed below. Latchbolt 9/16" – 3/4” After releasing the latchbolt, the • 5 strike body and faceplates keeper returns to the locked position. • All mortise locksets listed • For new and retrofit installation with 55-B & 55-C • No relocation of the centerline.

55-A • Grade 1 or equivalent After releasing the latchbolt, the • Bored (Cylindrical) locks. Latchbolt 9/16" – 3/4” keeper returns to the locked • No relocation of the centerline. • Adams Rite 4720 ANSI and position. compatible narrow stile locks.

55-B • Mortise locksets and exit devices • Accurate • Falcon with or without a deadlatch located • Arrow • Marks below the latchbolt. After releasing the latchbolt, the • Best • Sargent keeper returns to the locked position. • For new and retrofit installation • Corbin Russwin • Yale • No relocation of the centerline. • Dorma

55-C • Mortise locksets and exit devices with or without a deadlatch located • SDC above the latchbolt. • Baldwin After releasing the latchbolt, the • Hager keeper returns to the locked position. • For new and retrofit installation • Schlage • No relocation of the centerline.

55-D • Mortise locksets with a deadbolt and a deadlatch located below • Accurate • Falcon When the deadbolt is projected the latchbolt. • Arrow • Marks manually, the strike will not release. When the deadbolt is retracted, • Deadbolt will not release. • Best • Sargent • Corbin Russwin • Yale access is accomplished by • For new and retrofit installation • Dorma electrically releasing the keeper. • No relocation of the centerline.

55-E • Mortise lockset with a deadbolt. When the deadbolt is projected manually, the strike will not release. • Deadbolt will not release. • Baldwin When the deadbolt is retracted, • For new and retrofit installation access is accomplished by electrically releasing the keeper. • No relocation of the centerline.

55-F • Mortise locksets with a deadbolt When the deadbolt is projected and a deadlatch located above manually, the strike will not release. the latchbolt. • SDC • Schlage When the deadbolt is retracted, access is accomplished by • For new and retrofit installation • Hager electrically releasing the keeper. • Deadbolt will not release.

P:\INSTALLATION INST\ELECTRIC STRIKES\INST-55\INST-55.vsd REV F 02-19 Page 2 FIG. 1 WIRE DIAGRAM - 55 SERIES ELECTRIC STRIKE

Power SDC 12/24V Pigtail P/N CA-55-4 Connector 12V/600mA 24V/300mA Fail-Safe + 12 or 24V STRIKE Red + Red + Fail-Secure _ DC Black _ White MOV Power Supply Cable 1 Cable 2 -

NOTE: Power wires must not be connected AC to DC Rectifier SDC BR64XL to supply wires larger than 18AWG + RED + Monitoring ~ ~ YEL ~ 12 or 24V Connectors -WHT - AC ORG/BLK N/C (Powered = Open) YEL ~ Transformer WHT/BLK LCM COM * YEL/BLK N/O (Powered = Closed) * ORG N/C (Latched = Open) Strike Input: Dual Voltage WHT LBM 600 mA @ 12VDC YEL COM N/O (Latched = Closed) 300 mA @ 24VDC ORG/RED N/C (Bolt Thrown = Open) Contacts: SPDT, Dry, 5 Amp @ 30V WHT/RED DBM COM YEL/RED * NOTE: LCM Contacts Reversed N/O (Bolt Thrown = Closed) When in Failsafe Mode

HIGH SECURITY DOOR SECURE MONITORING: LCM & LBM Required LCM & LBM wired in series indicates door is closed, latched and strike is deadlocked or door is open or unlocked

FAIL SECURE MODE –Door Secure or Unlocked Status FAIL SAFE MODE –Door Secure or Unlocked Status YEL/BLK ORG/BLK WHT/BLK WHT/BLK COM LCM COM LCM ORG/BLK YEL/BLK N/O N/O N/C N/C ORG ORG WHT LBM WHT LBM YEL YEL

FIG. 2 FIELD REVERSIBLE FIG. 3 HORIZONTAL ALIGNMENT ADJUSTMENT FAILSAFE / FAILSECURE 3A-Nominal Alignment: Loosen mounting screws. Failsecure Mode: Factory supplied, Failsecure Shift strike body behind the faceplate horizontally. Failsafe Mode: Remove cover, push solenoid toward Tighten mounting screws. end of strike as shown below. 3B-Excessive Alignment Issues: Remove shim filler bar from keeper.

Remove Cover 3A 3B

Failsecure Shown

Failsafe

P:\INSTALLATION INST\ELECTRIC STRIKES\INST-55\INST-55.vsd REV F 02-19 Page 3 FIG. 4 FRAME PREPARATION – 55 Electric Strike FIG. 5 STRIKE DIMENSIONS

CENTER LINE OF STRIKE AND LOCK, AND LOCK BOLT SHOULD ALIGN HORIZONTALLY

2X TAP FOR #12-24 UNC THDS THRU

.250 (1/4”) 1.688 (1-11/16”) CL 3.375 4.875 (3-3/8”) (4-7/8”) +.015 +.015 3.625 -.000 -.000 (3-5/8”) .375 +.015 (3/8”) -.000

CL

.625 4.125 5/8” (4-1/8”) .005 .625 5/8” .734 1.250 1-1/4” +.015 -.000

2X 5/32” MTG TAB DEPTH (TYP) 47/64” STANDARD ANSI

FIG. 6 FACE PLATES – All faceplates are interchangeable for application requirements

55-A 55-B 55-C 55-D 55-E 55-F 7/8" 7/8" 7/8"

1-3/4" 2-5/16” 2-5/8" 2-31/32" 2 x 1-3/8"

1- 3/8" 5/8" 1-3/8" 7/8" 1/8" 3-1/4" 1-3/8" 3/8" 2x7/8"

P:\INSTALLATION INST\ELECTRIC STRIKES\INST-55\INST-55.vsd REV F 02-19 Page 4