AFWALL® FloWise® ELONGATED FLUSHOMETER with EVERCLEAN® BARRIER FREE AFWALL® FloWise® ELONGATED TOILET with EVERCLEAN®

• Wall-mounted flushometer valve toilet • Vitreous china • High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf) • Meets definition of HET (High Efficiency Toilet) when used with a high efficiency flush valve (1.28 gpf or 1.6 / 1.1 gpf dual flush) • Permanent EverClean® surface inhibits the growth of stain- and odor-causing bacteria, mold, and mildew on the surface • Condensation channel • Elongated bowl • Powerful direct-fed siphon jet action • 1-1/2" inlet spud • Fully-glazed 2-1/8" trapway • 10" x 12" water surface area • 100% factory flush tested

❏ 3351.001 Elongated bowl only, top spud SEE REVERSE FOR ROUGHING-IN DIMENSIONS ❏ 3352.001 Elongated bowl only, top spud with slotted rim for holding (White only) ❏ 3353.001 Elongated bowl only, back spud To Be Specified: ❏ ❏ Color: ❏ White ❏ Bone ❏ Linen 3354.001 Elongated bowl only, back spud with ❏ Seat: slotted rim for bedpan holding (White only) ❏ American Standard #5901.100 Heavy duty open front less cover System MaP* Score: ❏ American Standard #5905.100 Extra heavy • 1,000 grams of miso @ 1.6 gpf or 1.28 gpf when used with an American Standard flush valve duty open front less cover ❏ Flushometer Valve: * Maximum Performance (MaP) testing performed by IAPMO ❏ R&T Lab. MaP Report conducted by Veritec Consulting, Inc. 1.6 gpf: and Koeller and Company. ❏ Sensor-Operated: American Standard Selectronic® DC Power #6065.161.002 (Top Spud) Component Parts: ❏ Sensor-Operated: American Standard Selectronic® ❏ 047007-0070A Inlet Spud (furnished with bowl) AC Power #6067.262.002 (Back Spud) ❏ Manual: American Standard #6047.161.002 Nominal Dimensions: (Top Spud) 660 x 356 x 381mm ❏ 1.28 gpf: (26" x 14" x 15") ❏ Sensor-Operated: American Standard Selectronic® DC Power #6065.121.002 (Top Spud) Recommended working pressure–between ❏ Sensor-Operated: American Standard Selectronic® 25 psi at valve when flushing and 80 psi static AC Power #6067.222.002 (Back Spud) Fixture only, less seat, bolt caps, and ❏ Manual: American Standard #6047.121.002 flushometer valve (Top Spud) ❏ 1.6 / 1/1 gpf Dual Flush: Compliance Certifications - ❏ Sensor-Operated: American Standard Selectronic® Meets or Exceeds the Following Specifications: DC Power #6065.761.002 (Top Spud) • ASME A112.19.2-2008/CSA B45.1-08 for Vitreous China Fixtures

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES - CHECK LOCAL CODES. When installed so top of seat is 432 to 483mm (17" to 19") from the finished floor. M81 © 2011 AS America Inc. Rev. 11/11 AFWALL® FloWise® ELONGATED FLUSHOMETER TOILET VITREOUS CHINA with EVERCLEAN® BARRIER FREE

3351.001/3352.001

FINISHED WALL 1" N.P.T. OR C.W.T. SUPPLY AS REQUIRED TO FLUSH VALVE

C/L 660mm (26") 121mm (4-3/4") 73mm (2-7/8") 356mm 470mm (14") (18-1/2") 1-1/2" SPUD (4") 22mm 292mm C/L OF SEAT POST (7/8") (11-1/2") 19mm HOLES 140 mm HOLES (3/4") (5-1/2") CENTER

95mm 330mm (3-3/4") 229mm (13") 381mm (9") 191mm (15") (7-1/2")

FINISHED 133mm 70mm FLOOR C/L OF (5-1/4") (2-3/4") OUTLET 133mm (5-1/4") 32 mm (1-1/4")

3353.001/3354.001

FINISHED WALL

660mm (26") 76mm(3) DIA. HOLE IN WALL FOR 1-1/2" SPUD C/L 470mm (18-1/2") 356mm (14") C/L OF SEAT POST HOLES 140mm(5-1/2") CENTERS 89mm (3-1/2") 330mm (3/4") (13") 330mm 283mm 19mm 229mm (13") (11-1/8") 95mm (4) 22mm (7/8") (9") 191mm (3-3/4") DIA. HOLES (7-1/2")

381mm (15") FINISHED 133mm FLOOR C/L OF (5-1/4") OUTLET 70mm (2-3/4") (5-1/4") 133mm 32mm (1-1/4")

NOTES: ● Toilet designed to meet ADA accessibility standards when top of seat height set at 432 to 483mm (17" to 19") from finished floor. PRODUCT 3351 AND 3353 SHOWN, 3352 AND 3354 SAME EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING. WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING NOT RECOMMENDED). SUGGESTED 2mm (1/16) CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. CARRIER FITTING AS REQUIRED TO BE FURNISHED BY OTHERS. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORT.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages

M82 © 2011 AS America Inc. Rev. 11/11