Item Name Proper Use Beaker Glass Containers Used to Hold Approximate Volumes of Liquid Beaker Tongs Used to Transfer Hot Beaker

Total Page:16

File Type:pdf, Size:1020Kb

Item Name Proper Use Beaker Glass Containers Used to Hold Approximate Volumes of Liquid Beaker Tongs Used to Transfer Hot Beaker Item Name Proper use Glass containers used to hold Beaker approximate volumes of liquid Used to transfer hot beakers Beaker tongs *Rubber tips Used to precisely deliver solutions, Buret especially in a titration Support of equipment setup; uses Ring stand ring clamps Used to heat substances over open flame Bunsen burner Connects to methane supply with rubber tubing Used to heat small amounts of solid Crucible substances to high temperatures Used to pick up and hold small ceramic items, especially crucibles Crucible tongs and evaporating dishes *no rubber tips Plastic pipette used to transfer small Disposable volumes of liquid or solution pipette *no volume measurements Support device for beakers, flasks, IRON RING or other lab equipment Like a beaker May be heated Erlenmeyer flask Frequently used for titrations Small mouth accommodates a stopper for storage or shaking Used to contain small volumes of Evaporating dish solutions in order to evaporate the solvent Used to measure one exact and precise volume of solution Volumetric flask *most precise way to measure large volumes *one line only Holds filter paper used to separate solids from liquids Funnel Used to transfer liquids into small mouth containers Used to stir and assist in pouring Glass stir rod liquids Graduated Used to measure and deliver cylinder approximate volumes of liquids CLAY supports items being heated on ring TRIANGLE stand Electronic Used to determine mass Balance Attaches to ring stand to support Ring clamp equipment Used to seal flasks and test tubes Rubber stoppers Some have holes for thermometers Used to hold the substance when Weigh boat weighing Used to transfer solids Spatulas *many sizes and shapes available (spoon, scoopula) Used to hold substance when Foil pan heating. Striker Used to light Bunsen burners Test tube Glass cylinder that holds liquids being tested in an experiment *can be heated Holds a number of test tubes or Test tube rack disposable pipettes Connects to ring stand to hold test Test tube clamp tube over flame or water bath Used to put inside the funnel while Filter paper filtering. Separate solids and liquids. Spring metal holder used to hold or transfer hot test tubes Test tube holder *old ones will have lost springiness and may drop test tubes Wooden Splint Used to light fire Used to cover evaporating dishes Watch glass and beakers *Deeper than spot plate Well plate Used for microscale labs Used to spread heat of a Bunsen Wire gauze burner flame measures temperature of gas or THEROMETER liquid samples .
Recommended publications
  • Lab Equipment Erlenmeyer Flask
    Lab Equipment Erlenmeyer Flask • Erlenmeyer flasks hold solids or liquids that may release gases during a reaction or that are likely to splatter if stirred or heated. Beaker • Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Graduated Cylinder • A graduated cylinder is used to measure volumes of liquids. Test Tubes • Test tubes are used to hold small amounts of liquid and to conduct small chemical reactions in. Test Tube Clamp • A test tube holder is useful for holding a test tube which is too hot to handle. Test tube and beaker Brushes • Test tube brushes are used to clean test tubes and graduated cylinders. • Forcing a large brush into a small test tube will often break the tube. Test Tube Racks • Test tube racks are for holding and organizing test tubes on the laboratory counter. Plastic racks may melt in contact with very hot test tubes. Spot Plates • Spot plates are used when we want to perform many small scale reactions at one time. We will use these many times during the year. Watch Glass • A watch glass is used to hold a small amount of solid, such as the product of a reaction. Glass Stir Rod • A glass rod is used to manually stir solutions. It can also be used to transfer a single drop of a solution. Funnel • A funnel is used to aid in the transfer of liquid from one vessel to another. • A funnel is used to separate a solid from a liquid Wash Bottle • A wash bottle has a spout that delivers a wash solution to a specific area.
    [Show full text]
  • Laboratory Glassware N Edition No
    Laboratory Glassware n Edition No. 2 n Index Introduction 3 Ground joint glassware 13 Volumetric glassware 53 General laboratory glassware 65 Alphabetical index 76 Índice alfabético 77 Index Reference index 78 [email protected] Scharlau has been in the scientific glassware business for over 15 years Until now Scharlab S.L. had limited its sales to the Spanish market. However, now, coinciding with the inauguration of the new workshop next to our warehouse in Sentmenat, we are ready to export our scientific glassware to other countries. Standard and made to order Products for which there is regular demand are produced in larger Scharlau glassware quantities and then stocked for almost immediate supply. Other products are either manufactured directly from glass tubing or are constructed from a number of semi-finished products. Quality Even today, scientific glassblowing remains a highly skilled hand craft and the quality of glassware depends on the skill of each blower. Careful selection of the raw glass ensures that our final products are free from imperfections such as air lines, scratches and stones. You will be able to judge for yourself the workmanship of our glassware products. Safety All our glassware is annealed and made stress free to avoid breakage. Fax: +34 93 715 67 25 Scharlab The Lab Sourcing Group 3 www.scharlab.com Glassware Scharlau glassware is made from borosilicate glass that meets the specifications of the following standards: BS ISO 3585, DIN 12217 Type 3.3 Borosilicate glass ASTM E-438 Type 1 Class A Borosilicate glass US Pharmacopoeia Type 1 Borosilicate glass European Pharmacopoeia Type 1 Glass The typical chemical composition of our borosilicate glass is as follows: O Si 2 81% B2O3 13% Na2O 4% Al2O3 2% Glass is an inorganic substance that on cooling becomes rigid without crystallising and therefore it has no melting point as such.
    [Show full text]
  • LAB: One Tube Reaction Part 1
    AP Chemistry LAB: One Tube Reaction Part 1 Objective: To monitor and document the chemical changes occurring in a single test tube containing a predetermined mixture of chemicals. Materials: test tube, iron nail, sodium chloride, copper (II) sulfate, distilled water, glass stirring rod, tissue paper, parafilm wax Procedures: 1. Label a test tube to identify your group 2. Fill approx. 1/3 of the test tube with copper (II) sulfate crystals. Gently tap the tube to allow the crystals to settle. 3. Using a glass stirring rod, carefully cover the crystals with a layer of Kimwipe tissue paper. 4. Slowly, and with as little disturbance as possible, add enough distilled water to just cover the paper and blue crystals. 5. Repeat the process for the sodium chloride, filling approx. 1/3 of the test tube. Gently tap the tube to allow the crystals to settle. 6. Push more tissue paper into the test tube on top of the white crystals. 7. Add enough water to cover the tissue paper and white crystals. 8. Obtain an iron nail and expose the surface by rubbing with sand paper. 9. Carefully slide the nail into the test tube. 10. Continue adding water until the nail is completely covered. 11. Cover the test tube with parafilm wax and record your Day 1 observations. 12. Return the test tube to the test tube rack. 13. Continue to monitor and record your observations for the next several days, as indicated in the data table. Data: 1. Complete the NFPA label for the two chemicals used in this lab.
    [Show full text]
  • Set up for Heating Kcl + Kcloз
    Set Up for heating KCl + KClOз Crucible with unknown mixture plus MnO₂ Extension clamp Bunsen Burner To Gas Line Set Up for heating KCl + KClOз by Ashley Kajioka is licensed under a Creative Commons Attribution 4.0 International License. Procedure: Obtain a porcelain crucible, crucible lid, and a clay triangle. Clean the crucible, removing any loose particulate matter, and check the crucible for cracks. It is not necessary to remove all debris from the crucible as most of it has been fused to the porcelain and cannot be removed. In you fume hood, set up the apparatus as shown in Figure 5. a . b. e. Figure 5: Crucible setup d. a. Ring stand b. Crucible lid c. Iron ring d. Clay triangle c. e. Crucible “Lab Instructions” by Ashley Kajioka is licensed under CC BY 4.0 Using your crucible tongs, practice the following techniques on the cool crucible: Lifting the lid from the crucible Placing the lid ajar so that the crucible is slightly open, but the lid will not fall off, as in Figure 5. Quickly, but gently, pushing the lid from its ajar position to completely cover the crucible Lifting the crucible, with its lid, from the clay triangle Carrying the crucible and lid while supporting from underneath with your wire gauze. Practicing these techniques may seem silly, but it is worth your time to do so. Would you rather repeat a trial because you dropped a crucible, shattering it into a million pieces? With your covered crucible in the clay triangle, fire the crucible for 3-5 minutes.
    [Show full text]
  • Equipment Detailsr07
    Lab Equipment Details Lab Equipment Glass Flasks 150ml 250ml 500ml Lab Equipment Glass Beakers 150ml 250ml 500ml Lab Equipment Glassware But once removed, only the cap stays highlighted. Droppers critical to Lab An activated Dropper coursework can be found highlights the entire bottle. already in the workspace. Dropper Dropper Dropper Activated In Use Lab Equipment Gastight Syringe Small A pre-filled gastight syringe can be used with a NMR tube to safely fill through the top in preparation for use with the NMR spectrometer. Gastight Syringe NMR Tube with Holder with Holder Lab Equipment NMR Tube Spinner An NMR Tube filled with gas for use with the NMR Spectrometer Simply use the NMR Tube with needs to be inserted into the the Tube Spinner. Spinner before it can be used. NMR Tube NMR Tube Spinner NMR Tube Spinner with Holder with NMR Tube inserted Once the Tube slotted into the holder is inserted into the top part of the spectrometer, users can type in a number for Lab Equipment the frequency they’d like to scan. NMR Spectrometer XL The NMR Tube holder can then be slotted into the highlighted tube on the NMR Spectrometer. NMR Tube filled with appropriate substance is slotted (used with) in the holder. Lift will perpare the Spectrometer for the tube holder insertion. Scan No. Allows the user to change the frequency at which the tube is scanned The NMR Tube holder can then be slotted into the top tube on Lab Equipment the NMR Spectrometer. NMR Spectrometer XL NMR Tube filled with appropriate substance is slotted (used with) in the holder.
    [Show full text]
  • Environmental Chemistry Method Methoxyfenozide & Degradates In
    Dow AgroSciences LLC Study ID: 110356 Page 12 Method Validation Study for the Detennination of Residues of Methoxyfenozide and its A-ring • Phenol Metabolite and B-ring Mono Acid Metabolite in Surface Water, Ground Water and Drinking Water by Liquid Chromatography with Tandem Mass Spectrometry INTRODUCTION J This method is applicable for the quantitative detennination of residues of methoxyfenozide and its A-ring phenol metabolite and B-ring mono acid metabolite in surface, ground and drinking water. The method was validated over the concentration range of 0.05-1.0 µg/L with a validated limit of quantitation of 0.05 µg/L. Common names, chemical names, and molecular formulas for the analytes are given in Table I. This study was conducted to fulfill data requirements outlined in the EPA Residue Chemistry Test Guidelines, OPPTS 850. 7100 (/). The validation will also comply with the requirements of EU Council Regulation (EC) No. 1107/2009 with particular regard to Section 3 of SANCO/3029/99 rev.4 and Section 3 of SANCO/825/00 rev.8.1 as well as PMRA Regulatory Directive Dir98-02 (2-4). The validation was conducted following Dow AgroSciences SOP ECL-24 with exceptions noted in the protocol or by protocol amendment. Method Principle Residues of methoxyfenozide, its A-ring phenol metabolite and its B-ring mono acid metabolite • are extracted from water samples by taking a l 0.0-mL aliquot and placing in an I I -dram (45-mL) glass vial equipped with a PTFE-lined cap or a 50-mL polypropylene centrifuge tube equipped with a cap.
    [Show full text]
  • Uv and Visible Spectroscopy1
    Page 1 of 4 I. INTRODUCTION TO UV AND VISIBLE SPECTROSCOPY1 When white light passes through or is reflected by a colored substance, a characteristic portion of the mixed wavelengths is absorbed. The remaining light will then assume the complementary color to the wavelength(s) absorbed. Thus, absorption of 420-430 nm light renders a substance yellow, and absorption of 500-520 nm light makes it red. Green is unique in that it can be created by absorption close to 400 nm as well as absorption near 800 nm. When sample molecules are exposed to light having an energy that matches a possible electronic transition within the molecule, some of the light energy will be absorbed as the electron is promoted to a higher energy orbital. An optical spectrometer records the wavelengths at which absorption occurs, together with the degree of absorption at each wavelength. The resulting spectrum is presented as a graph of absorbance (A) versus wavelength. Absorbance usually ranges from 0 (no absorption) to 2 (99% absorption), and is precisely defined in context with spectrometer operation. Because the absorbance of a sample will be proportional to the number of absorbing molecules in the spectrometer light beam (e.g. their molar concentration in the sample tube), it is necessary to correct the absorbance value for this and other operational factors if the spectra of different compounds are to be compared in a meaningful way. The corrected absorption value is called "molar absorptivity", and is particularly useful when comparing the spectra of different compounds and determining the relative strength of light absorbing functions (chromophores).
    [Show full text]
  • ARC Laboratory Manual for Architectural Conservators
    A LABORATORY MANUAL FOR ARCHITECTURAL CONSERVATORS Jeanne Marie Teutonico ICCROM Rome 1988 CONTENTS Foreword v Preface vii General Principles: Laboratory Science 1. Sampling 3 2. Measurement and Error: Precision, Accuracy, Statistics 7 3. Measurement: Mass (Use of the Balance) 11 4. Measurement: Length (Use of the Vernier Caliper and Micrometer) 16 5. Measurement: Volume 21 6. Measurement: Solutions 26 7. Measurement: pH 30 Porous Building Materials 8. Water Absorption by Total Immersion 35 9. Water Drop Absorption 41 10. Penetration of Water: Capillary Action 43 11. Porosity of Granular Beds 45 12. Porosity in Solids: Indirect Measurement by Water Absorption 50 13. Porosity in Solids: Hydrostatic Weighing 52 14. Movement of Salts 56 15. Salt Crystallization 57 16. Qualitative Analysis of Water-soluble Salts and This publication was printed with a generous Carbonates 58 contribution from the government of 17. Semiquantititive Analysis of Water-soluble Salts 68 Finland. Earthen Building Materials 18A. Particle Size Analysis: Part I Sieving Procedure 73 ISBN 92-9077-083-X Via di San Michele 13 00153 Rome RM, Italy Printed in Italy III Earthen Building Materials (continued) FOREWORD 18B. Particle Size Analysis: Part II Sedimentation Procedure: Hydrometer Method 83 19. Plastic Limit of Soils 96 After his appointment as director of ICCROM in 1977, Sir Bernard FEILDEN proposed to emphasize the interdisciplinary 20. Liquid Limit of Soils 102 character of conservation by introducing scientists to field work and architects to laboratories. Consequently it was decided to introduce a series of laboratory exercises Stone. Brick and Mortars designed for the needs of architectural conservators and conservation architects in the program of the International 21.
    [Show full text]
  • Simple Chemical Experiments Simple Chemical Experiments
    SIMPLE CHEMICAL EXPERIMENTS SIMPLE CHEMICAL EXPERIMENTS By ALFRED MORGAN Illustrated by THE AUTHOR APPLETON-CENTURY-CROFTS, INC. NEW YORK COPYRIGHT, 1941, BY D. APPLETON-CENTURY COMPANY, INC All rights reserved. This book, or parts thereof, must not be reproduced in any form without permission of the publisher. PRINTED IN THE UNITED STATES OF AMERICA CONTENTS CHAPTER PAGE I. YOUR LABORATORY i II. EXPERIMENTS WITH PRECIPITATES .... 26 III. EXPERIMENTS WITH SULFUR AND SOME OF ITS COMPOUNDS 54 IV. EXPERIMENTS WITH OXYGEN AND OXYGEN COM­ POUNDS 73 V. EXPERIMENTS WITH GASES AND SOME OF THEIR COMPOUNDS 103 VI. CHEMICAL TESTS 123 VII. SAFE "FIREWORKS" 144 VIII. EXPERIMENTS WITH A FEW ORGANIC COMPOUNDS 156 IX. CHEMICAL TRICKS AND MAGIC 170 X. MISCELLANEOUS EXPERIMENTS 186 XI. PRACTICAL USES FOR YOUR CHEMICAL KNOWL­ EDGE 214 XII. THE CHEMICALS YOU WILL NEED . .231 INDEX OF CHEMICALS 259 GENERAL INDEX 263 V SIMPLE CHEMICAL EXPERIMENTS *> CHAPTER I I YOUR LABORATORY I OST of the experiments described in this book can be M performed without elaborate equipment or apparatus. | For them you will need only a few bottles, test-tubes, meas- i uring-spoons, and an alcohol lamp. Jelly glasses, mayonnaise f jars, small enameled saucepans, and thin glass tumblers can | often be substituted for the beakers, flasks, and glassware of I the professional chemist. t A few of the experiments require beakers, flasks, tubing, | funnels, filter paper, crucibles, mortar and pestle, and Bunsen I burner. The small sizes of these are not expensive. Frequently the cost of apparatus and chemicals can be shared by estab­ lishing a "community" laboratory which is used by two or more experimenters.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Corning Life Sciences Selection Guide Issue 6
    www.corning.com/lifesciences Corning Life Sciences Selection Guide Issue 6 Trust Corning for Your Research For superior quality and performance in life science research tools, you can count on Corning. Our comprehensive line of advanced products and technologies is designed to meet your evolving needs in cell-based and genomics research. To learn more, please visit www.corning.com/lifesciences, or call 1.800.492.1110. Customers outside the U.S., please call 1.978.442.2200 or contact your local support office (listed below). Corning Incorporated Worldwide India Taiwan United Kingdom Life Sciences Support Offices t 91-124-235 7850 t 886 2-2716-0338 t 0800 376 8660 f 91-124-401 0207 f 886 2-2716-0339 f 0800 279 1117 Corning BV Life Sciences ASIA/PACIFIC Japan All Other European EUROPE Koolhovenlaan 12 Australia t 81 (0) 3-3586 1996/1997 Countries 1119 NE Schiphol Rijk t 61 2-9416-0492 f 81 (0) 3-3586 1291/1292 France t 31 (0) 20 659 60 51 The Netherlands f 61 2-9416-0493 Korea t 0800 916 882 f 31 (0) 20 659 76 73 f 0800 918 636 Corning Incorporated China t 82 2-796-9500 f 82 2-796-9300 Germany LATINAMERICA Life Sciences t 86 21-3222-4666 t 0800 101 1153 Brasil Tower 2, 4th Floor f 86 21-6288-1575 Singapore f 0800 101 2427 t (55-11) 3089-7419 900 Chelmsford St. Hong Kong t 65 6733-6511 The Netherlands f (55-11) 3167-0700 Lowell, MA 01851 t 852-2807-2723 f 65 6861-2913 Mexico t 800.492.1110 f 852-2807-2152 t 31 20 655 79 28 New! t (52-81) 8158-8400 t 978.442.2200 f 31 20 659 76 73 f (52-81) 8313-8589 f 978.442.2476 www.corning.com/lifesciences Online ordering now available 6/08 6M APC CLS–PSG–001-A4-REV6 Corning, Costar, CellBIND, CellCube, CellSTACK, DNA-BIND, Lambda, Octapette, Spin-X, Stripette, Stripwell, Thermowell, Transtar-96, Transwell,, 8-Pette, and 12-Pette are registered trademarks of Corning Incorporated, Corning, NY.
    [Show full text]
  • 20 Pts. Chemistry Lab: Writing Chemical Equations I
    Name(s): ________________________________________________ 20 Pts. Chemistry Lab: Writing Chemical Equations I. Purpose: To observe, predict, classify, and write balanced chemical equations that illustrate a chemical reaction. II. Procedure: 1. At each lab bench station follow the directions to perform the experiment. You must record all observations carefully. A significant portion of the grade is based on your ability to describe a chemical reaction in words as well as symbols. 2. Complete the rest of the table for each station's experiment. Classify as double displacement, single displacement, decomposition, synthesis, or combustion. Include phase notation in your balanced chemical equation. Clean up after each experiment. 3. Wear safety glasses! III. Analysis: Data: Station 1-a: Directions: Place 20 drops of ethyl alcohol in an evaporating dish. Cap and remove the bottle from the work area. Obtain a test tube that is dry on the outside and fill it 1/3rd full of cold water. Light a lighter and bring the flame close to the alcohol. Turn off lighter as soon as the alcohol ignites. With a test tube holder place the tube above the burning alcohol. Observe the outside of the test tube. Allow all of the alcohol to burn. Observation Classification Balanced chemical equation with phase not. Station 1-b: Directions: Place a scoopula of sodium hydrogen carbonate in a 150-ml beaker. Add 20-ml of vinegar (dilute acetic acid). Note the temperature of the beaker. "Pour" the gas (Not the liquid!) evolved from the reaction mixture onto the evaporating dish with the burning alcohol. Observation Classification Balanced chemical equation with phase not.
    [Show full text]