B4 Building Works Standard Specifications THE REPUBLIC OF UGANDA MINISTRY OF WORKS AND TRANSPORT STANDARD SPECIFICATIONS (DRAFT) August 2012 B4 BUILDING WORKS BUILDING B4 FOREWORD The mission of the Ministry of Works and Transport (MoWT) is to promote an adequate, safe and well maintained works and transport infrastructure and services so as to effectively contribute to the socio-economic development of the country. In exercising this mission and in discharging its responsibilities, the Ministry is issuing a series of Design Manuals, Guidelines, Codes and Standards, of which the “Standard Specifications for Building Works” is one part thereof. The Standard Specifications for Building Works will be a nationally recognized document which will serve as a standard reference for the preparation of specifications for works to be undertaken on building construction projects. The major benefits to be gained in applying this document are the harmonization of professional practice in the building construction in Uganda and curtailment of informal developments so as to ensure well-planned, well- maintained, safe, cost effective and decent building developments and human settlements throughout the country. The Standard Specifications will be periodically updated and new editions issued to cater for the dynamic technological developments in the construction industry. Abraham Byandala Minister of Works and Transport August 2012 Ministry of Works and Transport Standard Specifications for Building Works General Table of Contents Part 1: Architectural, Structural and General Works Part 2: Building Sanitation Part 3: Electrical Services Ministry of Works and Transport i Standard Specifications for Building Works TABLE OF CONTENTS PART 1. ARCHITECTURAL, STRUCTURAL and GENERAL WORKS Page 1.0 GENERAL MATTERS ...................................................................................................... 2 1.1 General Conditions of Contract ............................................................................... 2 1.2 Instructions to Bidders ............................................................................................. 2 1.3 Scope of Contractor’s obligations ........................................................................... 2 1.4 Interpretation of Terms ............................................................................................ 2 1.5 Workmanship .......................................................................................................... 3 1.6 Codes of Practices .................................................................................................. 3 1.7 Materials .................................................................................................................. 3 1.8 Ordering of Materials ............................................................................................... 3 1.9 Proprietary of Materials ........................................................................................... 4 1.10 Samples .................................................................................................................. 4 1.11 Prove Vouchers ....................................................................................................... 4 1.12 Tests ........................................................................................................................ 4 1.13 Payment of tests ...................................................................................................... 5 1.14 Test Samples .......................................................................................................... 5 1.15 Rejected Workmanship and Materials .................................................................... 5 1.16 Material intended for Works .................................................................................... 5 1.17 Overtime or Nightwork ............................................................................................ 5 1.18 Nuisance to adjoining buildingsand property .......................................................... 6 1.19 Existing and adjacent property ................................................................................ 6 1.20 Damage to Public and Private Roads ..................................................................... 6 1.21 Existing Services ..................................................................................................... 6 1.22 Watching and Lighting ............................................................................................. 6 1.23 Licenses and Permits .............................................................................................. 6 1.24 Notices and Fees .................................................................................................... 7 1.25 Definition of “Fix only” ............................................................................................. 7 1.26 Attendance of Nominated Sub Contractors ............................................................ 7 1.27 Temporary Roads. .................................................................................................. 7 1.28 Temporary Fencing ................................................................................................. 8 1.29 Storage of Materials ................................................................................................ 8 1.30 Sheds for Operatives .............................................................................................. 8 1.31 Site Office ................................................................................................................ 8 1.32 Site Meetings ........................................................................................................... 8 1.33 Work Diary ............................................................................................................... 8 1.34 Foreman-in-Charge ................................................................................................. 9 Ministry of Works and Transport i Standard Specifications for Building Works 1.35 Temporary Latrines and Ablutions .......................................................................... 9 1.36 Water for Works ...................................................................................................... 9 1.37 Light and Power ...................................................................................................... 9 1.38 Signboards .............................................................................................................. 9 1.39 Protection of Works ............................................................................................... 10 1.40 Keep and Deliver Site and Works Clean ............................................................... 10 1.41 Contingencies........................................................................................................ 10 2.0 WORKS OF DEMOLITION AND ALTERATIONS ......................................................... 10 2.1. Demolition ............................................................................................................. 10 2.2 Obstruction of Public Road etc.............................................................................. 10 2.3 Prevention of dust and Fans ................................................................................. 10 2.4 Removal of Rubbish .............................................................................................. 10 2.5 Disposal of Rubbish .............................................................................................. 10 2.6 Use of suitable material for hardcore .................................................................... 10 2.7 Dustproof Screens ................................................................................................ 10 2.8 Shoring .................................................................................................................. 10 2.9 Building Openings ................................................................................................. 11 2.10 Cutting Openings in existing Walls ....................................................................... 11 2.11 Existing Public Service Mains ............................................................................... 11 2.12 Government to retain ownership of old Materials ................................................. 11 2.13 Materials to be cleared away ................................................................................ 11 2.14 Definition out and Making Good ............................................................................ 11 3.0 EXCAVATION ................................................................................................................ 12 3.1 Clear Site ............................................................................................................... 12 3.2 Trees and Bushes to be Preserved ...................................................................... 12 3.3 Felling Trees .......................................................................................................... 12 3.4 Anthills ................................................................................................................... 12 3.5 Remove Vegetable Soil ......................................................................................... 12 3.6 Excavate to reduce level ......................................................................................
Recommended publications
  • TRUE DC Isolators for PV Systems N Market-Leading Design N 2, 4, 6 & 8 Pole Versions Available N Max
    SI TRUE DC Solar Isolator Brighter Solutions AC vs DC Safe Switching As any electrician is aware the nature of DC switching has to be considered with care because on disconnection an arc can occur that is more arduous than that produced with an AC load because there is no zero point on DC. The nature of this arc means that design considerations have to be made within the switch in order to quench this phenomenon; that not only includes significant contact gaps with high speed of operation, but also thermal transmissive materials. What must be considered is that any AC isolator is predominantly designed with materials chosen such that the load will be AC. This means that the load supply will be a 50/60Hz sine wave, whether it be 230VAC or 400VAC, etc. When switching AC it should be remembered that the nature of the load supply will always pass through ØVAC twice in every cycle and therefore although loads can be ardu- ous in type the supply is self-extinguishing. By that we mean that even if the isolator switches at peak load and an arc is formed between contacts, the action of the supply reducing to ØV means that the load will tend to zero and the arc will be extinguished. DC load, on the other hand, is always there and unless the load becomes zero, the power being pulled through the contacts will always be the same. So if the load is 500VDC 25A it will be 500V 25A now, in 1s , in 1min, in 1hour – that is constant.
    [Show full text]
  • A Practical Guide to the 17Th Edition of the Wiring Regulations
    A Practical Guide to the 17th Edition of the Wiring Regulations This page intentionally left blank A Practical Guide to the 17th Edition of the Wiring Regulations Christopher Kitcher AMSTERDAM • BOSTON • HEIDELBERG • LONDON NEW YORK • OXFORD • PARIS • SAN DIEGO SAN FRANCISCO • SINGAPORE • SYDNEY • TOKYO Newnes is an imprint of Elsevier Newnes is an imprint of Elsevier The Boulevard, Langford Lane, Oxford OX5, 1GB, UK 30 Corporate Drive, Suite 400, Burlington, MA 01803 First edition 2010 Copyright © 2010, Christopher Kitcher. Published by Elsevier Ltd. All rights reserved The right of Christopher Kitcher to be identified as the author of this work has been asserted in accordance with the Copyright, Design and Patents Act 1988. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or any information storage and retrieval system, without permission in writing from the publisher. Details on how to seek permission, further information about the Publisher’s permissions policies and our arrangements with organizations such as the Copyright Clearance Center and the Copyright Licensing Agency, can be found at our website: www.elsevier.com/permissions. This book and the individual contributions contained in it are protected under copyright by the Publisher (other than as may be noted herein). Notices Knowledge and best practice in this field are constantly changing. As new research and experience broaden our understanding, changes in research methods, professional practices, or medical treatment may become necessary. Practitioners and researchers must always rely on their own experience and knowledge in evaluating and using any information, methods, compounds, or experiments described herein.
    [Show full text]
  • JUNE, 2020 Implementation Guide Implementation Guide
    BUILDING INSPECTION BOOKLET JUNE, 2020 Implementation Guide Implementation Guide TABLE OF CONTENTS Foreward ............................................................................................................................................................3 Disclaimer ......................................................................................................................................................... 4 1.0 PROJECT DETAILS ...........................................................................................................................5 2.0 DESCRIPTION OF WORKS...........................................................................................................5 3.0 PROJECT TEAM .................................................................................................................................5 3.1 DEVELOPERS TEAM ...................................................................................................................5 3.2 CONSULTANTS TEAM ............................................................................................................... 6 3.3 CONTRACTORS TEAM .............................................................................................................. 7 4.0 BUILDING ARCHITECTURE ........................................................................................................ 8 4.1 BUILDING ARCHITECTURE FOR CLASS A AND B BUILDINGS .......................... 8 4.2 BUILDING ARCHITECTURE FOR CLASS C BUILDINGS .........................................19
    [Show full text]
  • IET Wiring Regulations BS 7671 18Th Edition
    — IET Wiring regulations BS 7671 18th edition Transient overvoltage protection 4 IET WIRING REGULATIONS BS 7671 18TH EDITION — The IET Wiring Regulations require all new electrical system designs and installations, as well as alterations and additions to existing installations, to be assessed against transient overvoltage risk and, where necessary, protected using appropriate surge protection measures (in the form of Surge Protection Devices SPDs). TRANSIENT OVERVOLTAGE PROTECTION - INTRODUCTION 3 — Transient overvoltage protection Introduction Based on the IEC 60364 series, the 18th Edition of BS 7671 Wiring regulations covers the electrical installation of buildings including the use of surge protection. The 18th Edition of BS 7671 applies to the design, In order to observe the Ligntning Protection Zone LPZ erection and verification of electrical installations, concept within BS 7671 and BS EN 62305, all other and also to additions and alterations to existing incoming metallic service lines, such as data, signal installations. Existing installations that have and telecommunications lines, are also a potential been installed in accordance with earlier editions route through which transient overvoltages to of BS 7671 may not comply with the 18th edition damage equipment. As such all such lines will require in every respect. This does not necessarily appropriate SPDs. mean that they are unsafe for continued use or require upgrading. BS 7671 clearly points the reader back to BS EN 62305 and BS EN 61643 for specific guidance. This is A key update in the 18th Edition relates to covered extensively in the Furse guide to BS EN 62305 Sections 443 and 534, which concern protection of Protection Against Lightning.
    [Show full text]
  • Overload Protection of an RCCB Or Switch in an LV Assembly to BS EN 61439-3
    Bringing power to life. Overload protection of an RCCB or switch in an LV assembly to BS EN 61439-3 BS 7671: 2018 IET Wiring Regulations 18th Edition specifies requirements for overload protection of an RCCB or switch in an LV assembly, Regulations 536.4.3.2, 536.4.5 and 536.4.202 refer. This bulletin provides BEAMA member’s guidance for RCCB and switch overload protection however; individual manufacturer’s instructions must be followed, particularly the rated current of the related assembly circuit Inc (A) which must be stated in the documentation supplied with the LV assembly e.g. distribution board or consumer unit. The rated current in the assembly circuit Inc (A) of the switch or RCCB shall be derived from one of the following two methods in diagrams 1 and 2. In both methods, circuits shall be designed so that a small overload of long duration is unlikely to occur. 1. Be greater than or equal to the sum of the rated current of all outgoing circuit OCPDs1 e.g. MCBs, fuses; see diagram 1. Diagram 1 I n1 or In 1 or Inc2 In 1 Inc2 In 3 + I n4 + In5 + In6 + In7 Inc2 or or Inc2 In3In4In5In6In7 In3In4In5In6In7 Inc2 = Rated current of a circuit (A) stated = Circuit-breaker by the assembly manufacturer which may be lower than the = Fuse unenclosed rated current marked on the device (switch disconnector Supplied from upstream 100 A BS 88-3 or BS 1361 cut-out supply fuse or RCCB) due to grouping & internal = Isolating switch / disconnector enclosure temperature etc.
    [Show full text]
  • International Electrical Standards & Regulations
    International electrical standards & regulations AN OVERVIEW OF ELECTRICAL INSTALLATIONS Introduction to the installations world he world of electrical installations knowledge of the wiring suited to your specific Tis not always straightforward. regulations and standards requirements in terms of Working on an international project which are applicable in electrical installations and electrical engineers are often bewildered the specific country. communication networks. by the extensive amount of electrical This document compares Continuous innovation standards and wiring regulations which the basic framework No less than 1 800 determines their decisions. of the standards. people are dedicated Therefore, it is essential full-time to research and Rely on the world’s Detailed knowledge for the design engineer development. On average, leading specialist of the wiring rules to obtain more detailed Legrand invests 5% of its As one of the world The purpose of this information by contacting sales each year in R&D. leading specialists document is to clearly the appropriate standards in wiring accessories, present the most and building regulations Sustainable Legrand actively participate frequently encountered organisations. Development: a priority to the elaboration of the sets of wiring rules, For many years, installation standards showing the main One of the most complete the Legrand Group at international (IEC), technical characteristics offer of the market has drawn strength regional (NEC) and local of each set of installation 130 000 catalogue items! from its values to ensure levels. Thus, the technical and main accessories For you, the wealth profitable, sustainable expertise of the Legrand standards. Obviously, on of the Legrand Group’s and responsible growth people makes it possible any given project, it is catalogue offer is the in its business.
    [Show full text]
  • Connecting a Microgeneration System to a Domestic Or Similar Electrical Installation
    Best Pracce Guide 3 (Issue 3) Connecting a microgeneration system to a domestic or similar electrical installation (in parallel with the mains supply) Page 1 Best Practice Guide Electrical Safety First is indebted to the following organisations for their contribution and/or support to the development of this Guide: BEAMA In electronic format, this Guide is intended to be made available free www.beama.org.uk of charge to all interested parties. Further copies may be downloaded from the websites of some of the contributing organisations. British Gas www.britishgas.co.uk The version of this Guide on the Electrical Safety First website (www.electricalsafetyfirst.org.uk) will always be the latest. Feedback on any of the Best Practice Guides is always welcome – email Certsure [email protected] www.certsure.com Electrical Safety First is supported by all sectors of the electrical industry, approvals and research bodies, consumer interest City & Guilds organisations, the electrical distribution industry, professional institutes www.cityandguilds.com and institutions, regulatory bodies, trade and industry associations and federations, trade unions, and local and central government. ECA *Electrical Safety First (formerly the National Inspection Council for www.eca.co.uk Electrical Installation Contracting) is a charitable non-profit making organisation set up in 1956 to protect users of electricity against the ENA hazards of unsafe and unsound electrical installations. www.energynetworks.org HSE www.hse.gov.uk Institution of Engineering
    [Show full text]
  • BEAMA GUIDE to ARC FAULT DETECTION DEVICES :AFDD S; 05
    BEAMA AFDD GUIDE 07_19.qxp_BEAMA CAD guide 24/10/2019 08:53 Page 1 Bringing pow er to li fe. GUIDE TO ARC FAULT DETECTION DEVICES :AFDD s; Third Edition – October 2019 BEAMA AFDD GUIDE 07_19.qxp_BEAMA CAD guide 24/10/2019 08:53 Page 2 COMPANIES INVOLVED IN THE PREPARATION OF THIS GUIDE ABB Ltd Tower Court; Courtaulds Way Foleshill Enterprise Park MK Electric Coventry, West Midland,s CV6 5NX The Arnold Centre, Paycocke Road Tel: +44 (0) 2476 368 500 Basildon, Essex SS14 3EA https://new.abb.com/uk Tel: +44 (0) 1268 563 000 Fax: +44 (0) 1268 563 064 Email: [email protected] www.mkelectric.com/en-gb Eaton Electric Limited 270 Bath Road, Slough, Berkshire SL1 4DX Tel: +44 (0) 8700 545 333 Schneider Electric Ltd Email: [email protected] Stafford Park 5, Telford, Shropshire TF3 3BL www.eaton.com/uk Tel: +44 (0) 1952 290029 Fax: +44 (0) 1952 292238 www.schneider-electric.co.uk Gewiss UK Ltd 2020 Building, Cambourne Business Park Cambourne, Cambridge CB23 6DW Tel: +44 (0) 1954 712757 Electrium Sales Ltd (a Siemens Company) Fax: +44 (0) 1954 712753 Sharston Road, Wythenshawe Email: [email protected] Manchester M22 4RA www.gewiss.co.uk Tel: +44 (0) 161 945 3956 Fax: +44 (0) 8456 053114 www.electrium.co.uk GreenBrook Electrical 62 West Road, Harlow, Esssex CM20 2BG Tel + 44 (0) 1279 772772 Timeguard Ltd www.greenbrook.co.uk Victory Park, 400 Edgware Road London NW2 6ND Tel: +44 (0) 20 8450 0515 Fax: +44 (0) 20 8450 0635 Hager Ltd Email: [email protected] Hortonwood 50, Telford, www.timeguard.com Shropshire TF1 7FT Tel: +44 (0)1952 675 689 Email: [email protected] www.hager.co.uk Western Automation R&D Legrand Electric Ltd 2 Atreus Place, Poolboy, Ballinalsoe, Great King Street North, Co.
    [Show full text]
  • Connecting a Microgeneration System to a Domestic Or Similar Electrical Installation (In Parallel with the Mains Supply)
    Connecting a microgeneration system to a domestic or similar electrical installation (in parallel with the mains supply) Best Practice Guide 3 Best Practice Guide This is one of a series of Best Practice Guides produced by the Electrical Safety Council* in association with leading industry bodies for the benefit of electrical contractors and installers, and their customers. The Electrical Safety Council is indebted to the following organizations for their contribution to the development of this Guide: BEAMA Installation www.beamainstallation.org.uk British Gas www.house.co.uk CORGI www.trustcorgi.com Electrical Contractors’ Association www.eca.co.uk Energy Networks Association www.energynetworks.org Health and Safety Executive www.hse.gov.uk Institution of Engineering and Technology www.theiet.org Local Authority Building Control www.labc.co.uk Micropower Council www.micropower.co.uk NICEIC Group Ltd www.niceicgroup.com Renewable Energy Association www.r-p-a.org.uk SELECT (Electrical Contractors’ Association of Scotland) www.select.org.uk Published by: In electronic format, this Guide is intended to be made The Electrical Safety Council available free of charge to all interested parties. Further 18 Buckingham Gate copies may be downloaded from the websites of the London contributing organizations. SW1E 6LB The Electrical Safety Council is supported by all sectors of Tel: 0870 040 0561 Fax: 0870 040 0560 the electrical industry, approvals and research bodies, Email: [email protected] consumer interest organizations, the electrical distribution Website: www.electricalsafetycouncil.org.uk industry, professional institutes and institutions, regulatory The Electrical Safety Council and other contributors believe that the bodies, trade and industry associations and federations, guidance and information contained in this Guide is correct, but all trade unions, and local and central government.
    [Show full text]
  • B1 Code for Electrical Installations in Buildings
    THE REPUBLIC OF UGANDA MINISTRY OF WORKS AND TRANSPORT CODE FOR ELECTRICAL INSTALLATIONS IN BUILDINGS (DRAFT) B1 August 2012 FOREWORD The mission of the Ministry of Works and Transport (MoWT) is to promote an adequate, safe and well maintained works and transport infrastructure and services so as to effectively contribute to the socio-economic development of the country. In exercising this mission and in discharging its responsibilities, the Ministry is issuing a series of Design Manuals, Guidelines, Codes and Standards, of which the “Code for Electrical Installations In Buildings” is one part thereof. The Code for Electrical Installations In Buildings will be a nationally recognized document which will serve as a standard reference for the regulation of design and construction of electrical installations and equipment in buildings. The major benefits to be gained in applying this document are the harmonization of professional practice in the building construction in Uganda and curtailment of informal developments so as to ensure well-planned, well- maintained, safe, cost effective and decent building developments and human settlements throughout the country. The Regulations will be periodically updated and new editions issued to cater for the dynamic technological developments in the construction industry. Abraham Byandala Minister of Works and Transport August 2012 Regulations for Electrical Installations and Equipment in Buildings TABLE OF CONTENTS Definitions ..................................................................................................................iv
    [Show full text]
  • Best Practice Guide: Electrical Safety and Safe Isolation Procedures
    Best Practice Guide 2 (Issue 3) Guidance on the management of electrical safety and safe isolation procedures for low voltage installations This is one of a series of Best Practice Guides produced by Electrical Safety First* in association with leading industry bodies for the benefit of electrical contractors and installers, and their customers. In electronic format, this Guide is intended to be made available free of Electrical Safety First is indebted to the following charge to all interested parties. Further copies may be downloaded from organisations for their contribution and/or support to the the websites of some of the contributing organisations. development and revision of this Guide, and in particular to The version of this Guide on the Electrical Safety First website SELECT and the HSE for providing the initial draft: (www.electricalsafetyfirst.org.uk) will always be the latest. Feedback on any of the Best Practice Guides is always welcome – email [email protected] BEAMA www.beama.org.uk Electrical Safety First is supported by all sectors of the electrical industry, approvals and research bodies, consumer interest organisations, the BSI electrical distribution industry, professional institutes and institutions, www.bsigroup.com regulatory bodies, trade and industry associations and federations, trade unions, and local and central government. Certsure www.certsure.com *Electrical Safety First (formerly the National Inspection Council for Electrical Installation Contracting) is a charitable non-profit making City
    [Show full text]
  • Brighter Solutions IMO Is at the Forefront of Control Component Technology Specifically Developed for the Renewable Energy Market and in Particular Solar Energy
    Solar Product Range Brighter Solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the demands of safe and efficient DC switching or delivering tracking solutions that help to maximise solar energy conversion rates, you can be sure that IMO products have been developed to meet the highest technical and commercial standards. Contents Page IMO Solar Guide 4 DC Isolators 16 Lever Actuator Panel Mounting Switch 18 Base Mounting Switch 19 Single Hole Mounting Switch 20 Distribution Board Switch 21 Lever Actuator Lockable Single Hole Mounting Switch 22 Distribution Board Switch 23 Rotary Actuator Lockable Panel Mounting Switch 24 Base Mounting Switch 25 Enclosed Switch 26 Technical Data 27 Dimensions 35 AC Isolators 39 DC Contactors 40 Solar Connectors 44 DIN Terminals 45 Distribution Boxes 46 Solar Relays 47 Solar Cube (Solar Tracker) 48 Certifications 50 www.imopc.com IMO Solar Guide - Abbreviations AC Alternating Current DC Direct Current Rated Operational Current Ie IMO IMO Precision Controls Short-Circuit Current ISC Thermal Current Ith MPPT Maximum Power Point Tracking PV Photovoltaic Open-Circuit Voltage VOC References BS 7671 Requirements for Electrical Installations EN 60364-7-712 Low-voltage electrical installations. Part 7-712: Requirements for special installations or locations. Photovoltaic (PV) power systems EN 60529 Specification for degrees of protection provided by enclosures (IP code) EN 60947-1 Low-voltage switchgear
    [Show full text]