S[SI HOST ADAPTERS for P[1. Vfsa, Fisa, and ISA SYSTEMS Revision History

Total Page:16

File Type:pdf, Size:1020Kb

S[SI HOST ADAPTERS for P[1. Vfsa, Fisa, and ISA SYSTEMS Revision History Technical Reference Manual ~ BU~lOGIC S[SI HOST ADAPTERS fOR P[1. VfSA, fISA, AND ISA SYSTEMS Revision History Revision Change Activity Date A Release 6/1/94 Compliance Statements This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re­ ceived, including interference that may cause undesired operations. Declaration of the Manufacturer/Importer We hereby certify that the SCSI Host Adapter for PCI, VESA, EISA and ISA, in compliance with the re­ quirements of BMPT Vfg 243/1991, is RFI suppressed. The normal operation of some equipment (e.g., . signal generators) may be subject to specific restrictions. Please observe the notices in the user's manual. The marketing and sale of the equipment was reported to the Federal Office for Telecommunication Per­ mits (BZT). The right to retest this equipment to verify compliance with the regulation was given to the ZZF. Bescheinungung des Herstellers/lmporteurs Hiermit wird bescheinigt, das SCSI Host Adapter for PCI, VESA, EISA and ISA in Uebereinstimmung mit den Bestimmungen der BMPT-AmtsbIVfg 243/1991 funk-entstort ist. Der vorschriftsmassige Be­ treib mancher Gerate (z. B. Messender) kann allerdings gewissen Einschrankungen unterliegen. Beacht­ en Sie deshalb die Hinweise in der Bedienungsanleitung. Dem Bundesamt fUr Zulassungen in der Telekommunikation wurde das Inverkehrbringen dieses Gerates angezeigt und die Berechtigung zur Ueberpriifung der Serie auf die Einhaltung der Bestimmu­ ngen eingeraumt. EN 55 022 Declaration of Conformance This is to certify that BusLogic SCSI Host Adapters are shielded against the generation of radio interfer­ ence in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is de­ clared by the application of EN 55 022:1987 Class B (CISPR 22:1985/BS 6527:1988). Copyright © Copyright 1994 BusLogic Inc. All rights reserved. BusLogic Inc makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. BusLogic is not liable for any errors contained herein or incidental or consequential damages in connection with furnishing, per­ formance or use of this material. This document contains proprietary information which is protected by copyright. All rights are re­ served. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of BusLogic Inc. Trademarks Company and product names are trademarks or registered trademarks of their respective companies. Table of Contents Preface Part 1 Adapter Operation Part 2 pcr Host Adapters Part 3 VESA Host Adapters Part 4 EISA Host Adapters Part 5 ISA Host Adapters Index Preface The BusLogic SCSI Host Adapter Technical Reference Manual is intended for sys­ tem software programmers desiring to develop deviee driver software for BusLog­ ie's family of SCSI adapter products. This manual covers adapter architecture, hardware and software operation and in­ cludes electrical signaling information for each bus architecture. Products covered in this document include: • BT-946C PCI Fast SCSI Host Adapter (10 MBytes/sec synchronous data transfer rate; no floppy connector) • BT-440/445C VESAFast SCSI Host Adapter (10 MBytes/sec synchronous data transfer rate; BT-44OC has no floppy connector) • BT-746/747C EISA Fast SCSI Host Adapter (10 MBytes/sec synchronous data transfer rate; BT-746C has no floppy connector) • BT-545C PC/AT Fast SCSI Host Adapter (10 MBytes/ sec synchronous data transfer rate) • BT-540CF PC/AT Fast SCSI Host Adapter (with Centronics external SCSI con­ nector) Contents This manual is organized in the following manner: Part 1: Adapter Operation • Section 1 contains an overview to BusLogie's MultiMaster™ technology. • Section 2 details adapter hardware components and operation. • Section 3 discusses software operation between the host adapter and the host system. • Section 4 describes the adapter's SCSI electrical interface. • Section 5 describes the adapter's floppy controller interface. • Section 6 details adapter internal diagnostics. • Appendix A is a list of industry acronyms. Part 2: PCI Host Adapters • Section 1 includes descriptions and specifications for the BT-946C host adapter. • Section 2 describes the electrical interface for the BT-946C host adapter. • Section 3 contains the PCI bus timing diagrams. • Section 4 details the configuration for non-conforming PCI motherboards. Preface _ v Part 3: VESA Host Adapters • Section 1 includes descriptions and specifications for the BT-440 /44SC host adapter. • Section 2 describes the electrical interface for the BT-440/ 44SC host adapter. • Section 3 contains the VL-Bus timing descriptions. Part 4: EISA Host Adapters • Section 1 includes descriptions and specifications for the BT-746/747C host adapter. • Section 2 describes the electrical interface for EISA host adapters. • Section 3 contains the EISA bus master timing diagrams. Part 5: ISA Host Adapters • Section 1 includes descriptions and specifications for the BT-S4OCF and the BT- 54SC host adapters. • Section 2 describes the electrical interface for ISA host adapters. • Section 3 contains the ISA bus master timing diagrams. Related Documentation Refer to the user's guide provided with your BusLogic host adapter for details on host adapter installation and configuration. Notational Conventions The following conventions are used throughout this manual: Convention Description UPPERCASE Used to indicate the names of keys. A hyphen indicates an active low signal. + A plus sign indicates an active high signal. SCSI Host Adapter Technical Reference Manual _ vi 1 OU~lOGIC PART 1 ADAPUR OPfRATION . Part 1 : Contents Section 1-1: BusLogic MultiMastering Technology Introduction ........................................................................................................ :... 1-1 Bus Mastering DMA .............................................................................................. 1-1 Description ...................................................................................................... 1-2 Configuration .................................................................................................. 1-2 Bus Master Transfers ...................................................................................... 1-3 MultiMaster Advantages ............................................................................... 1-4 Section 1-2: Hardware Description Adapter Architecture ............................................................................................ 1-7 Bus Master DMA Controller ......................................................................... 1-8 Advanced SCSI Controller ............................................................................ 1-8 Microprocessor Unit (MPU) .......................................................................... 1-9 Local BIOS ROM ............................................................................................. 1-9 Floppy Disk Controller ................................................................................... 1-9 Host DMA Data Transfer Control. ...................................................................... 1-9 ISA .................................................................................................................... 1-9 EISA .................................................................................................................. 1-9 VESA .............................................................................................................. 1-10 PCI .................................................................................................................. 1-10 Hardware Registers ............................................................................................. 1-10 Control Register (Write Only) I/O Base Address + 0 ............................. 1-11 Status Register (Read Only) I/O Base Address + 0 ................................. 1-12 Command/Parameter Register (Write Only) I/O Base Address + 1 ... 1-13 Data In Register (Read Only) I/O Base Address + 1.. ............................. 1-14 Interrupt Register (Read Only) I/O Base Address + 2 ........................... 1-15 Reset Operations .................................................................................................. 1-17 Host-Initiated Reset Operations ................................................................. 1-17 SCSI Bus Reset Operations .......................................................................... 1-18 Section 1-3: Software Interface Bus Master Direct Memory Access (DMA) ...................................................... 1-22 Interrupt Processing ............................................................................................ 1-22 Host Adapter Commands .................................................................................. 1-23 Addressing Mode ................................................................................................ 1-31 24-Bit Mode Mailbox Commands ..................................................................... 1-31 24-Bit Mode Mailbox Initialization .......... ;........................................................ 1-32 24-Bit Mode Outgoing Mailbox Structure........................................................ 1-33 24-Bit Mode Incoming Mailbox Structure
Recommended publications
  • System Buses EE2222 Computer Interfacing and Microprocessors
    System Buses EE2222 Computer Interfacing and Microprocessors Partially based on Computer Organization and Architecture by William Stallings Computer Electronics by Thomas Blum 2020 EE2222 1 Connecting • All the units must be connected • Different type of connection for different type of unit • CPU • Memory • Input/Output 2020 EE2222 2 CPU Connection • Reads instruction and data • Writes out data (after processing) • Sends control signals to other units • Receives (& acts on) interrupts 2020 EE2222 3 Memory Connection • Receives and sends data • Receives addresses (of locations) • Receives control signals • Read • Write • Timing 2020 EE2222 4 Input/Output Connection(1) • Similar to memory from computer’s viewpoint • Output • Receive data from computer • Send data to peripheral • Input • Receive data from peripheral • Send data to computer 2020 EE2222 5 Input/Output Connection(2) • Receive control signals from computer • Send control signals to peripherals • e.g. spin disk • Receive addresses from computer • e.g. port number to identify peripheral • Send interrupt signals (control) 2020 EE2222 6 What is a Bus? • A communication pathway connecting two or more devices • Usually broadcast (all components see signal) • Often grouped • A number of channels in one bus • e.g. 32 bit data bus is 32 separate single bit channels • Power lines may not be shown 2020 EE2222 7 Bus Interconnection Scheme 2020 EE2222 8 Data bus • Carries data • Remember that there is no difference between “data” and “instruction” at this level • Width is a key determinant of performance • 8, 16, 32, 64 bit 2020 EE2222 9 Address bus • Identify the source or destination of data • e.g. CPU needs to read an instruction (data) from a given location in memory • Bus width determines maximum memory capacity of system • e.g.
    [Show full text]
  • Getting Started with Your VXI-1394 Interface for Windows NT/98 And
    VXI Getting Started with Your VXI-1394 Interface for Windows NT/98 VXI-1394 Interface for Windows NT/98 November 1999 Edition Part Number 322109D-01 Worldwide Technical Support and Product Information www.ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521, China 0755 3904939, Denmark 45 76 26 00, Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427, Hong Kong 2645 3186, India 91805275406, Israel 03 6120092, Italy 02 413091, Japan 03 5472 2970, Korea 02 596 7456, Mexico (D.F.) 5 280 7625, Mexico (Monterrey) 8 357 7695, Netherlands 0348 433466, Norway 32 27 73 00, Poland 48 22 528 94 06, Portugal 351 1 726 9011, Singapore 2265886, Spain 91 640 0085, Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2377 1200, United Kingdom 01635 523545 For further support information, see the Technical Support Resources appendix. To comment on the documentation, send e-mail to [email protected] © Copyright 1998, 1999 National Instruments Corporation. All rights reserved. Important Information Warranty The National Instruments VXI-1394 board is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period.
    [Show full text]
  • Mamaoma Writing EISA Bus Device Drivers
    DEC OSF/l mamaoma Writing EISA Bus Device Drivers Part Number: AA-QOR6A-TE DEC OSF/1 Writing EISA Bus Device Drivers Order Number: AA-QOR6A-TE February 1994 Product Version: DEC OSF/1 Version 2.0 or higher This guide contains information systems engineers need to write device drivers that operate on the EISA bus. The guide describes EISA bus­ specific topics, including EISA bus architecture and the data structures that EISA bus drivers use. digital equipment corporation Maynard, Massachusetts Restricted Rights: Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii). Digital Equipment Corporation makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description. Possession, use, or copying of the software described in this publication is authorized only pursuant to a valid written license from Digital or an authorized sublicensor. © Digital Equipment Corporation 1994 All rights reserved. The following are trademarks of Digital Equipment Corporation: ALL-IN-I, Alpha AXP, AXP, Bookreader, CDA, DDIS, DEC, DEC FUSE, DECnet, DEC station, DECsystem, DECUS, DECwindows, DTIF, MASSBUS, MicroVAX, Q-bus, ULTRIX, ULTRIX Mail Connection, ULTRIX Worksystem Software, UNIBUS, VAX, V AXstation, VMS, XUI, and the DIGITAL logo. UNIX is a registered trademark licensed exclusively by X/Open Company Limited. Open Software Foundation, OSF, OSFIl, OSFlMotif, and Motif are trademarks of the Open Software Foundation, Inc.
    [Show full text]
  • HP A5150A PCI Dual Port Ultra2 SCSI Host Bus Adapter
    HP A5150A PCI Dual Port Ultra2 SCSI Host Bus Adapter Service and User Guide Edition 2 Customer Order Number: A5150-90001 Manufacturing Part Number: A5150-96002 E0201 U.S.A. © Copyright 2001, Hewlett-Packard Company. Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty. A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your local Sales and Service Office. Restricted Rights Legend. Use, duplication or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies. HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto, California 94304 U.S.A. Use of this manual and flexible disk(s) or tape cartridge(s) supplied for this pack is restricted to this product only. Additional copies of the programs may be made for security and back-up purposes only. Resale of the programs in their present form or with alterations, is expressly prohibited.
    [Show full text]
  • AVA™-2902E/I PCI SCSI Host Adapter with External Or Internal SCSI Connector
    R AVA™-2902E/I PCI SCSI Host Adapter with External or Internal SCSI Connector OVERVIEW Support for the AVA-2902E/I adapters are embedded in Windows® 95 and The Adaptec AVA™-2902E/I host Windows NT™ and support for MS- adapters offer highly-compatible DOS® and Windows® 3.1x is available PCI-to-SCSI connectivity for non- through drivers which assure compati- booting peripherals such as scanners, bility with these desktop operating CD-recordable drives, removable systems. drives, and digital cameras. The AVA-2902E/I adapters provide PCI SCSI performance for use with IBM- Adaptec has developed strong rela- compatible PCs. For peripheral tionships with ISHVs (Independent OEMs who are looking for a PCI Software Hardware Vendors) to SCSI solution, Adaptec offers industry maximize product compatibility with standard host adapters, based on industry leading hardware and soft- proven designs. ware products. These relationships mean reduced technical support due KEY BENEFITS to increased compatibility, resulting in lower total cost of ownership. PRODUCT HIGHLIGHTS Simple to Install and Easy to Use • Industry standard SCSI PCI is inherently easy to use. Proven Quality and Reliability architecture for unmatched Plug-and-Play technology makes The AVA-2902E/I host adapters compatibility installations virtually automatic with have undergone thorough testing in no jumpers or switches to configure. • Plug-and-Play – no jumpers or Adaptec’s Product Test Laboratory. The Adaptec AVA-2902E/I adapters switches to configure, lowers Each board design is subjected to are based on industry-standard archi- technical support costs thousands of hours of functional, tecture to help OEMs reduce technical compatibility, and environmental • 32-bit PCI bus master for low support calls.
    [Show full text]
  • Ultra160 SCSI to PCI Host Adapters User Guide
    USER’S GUIDE Ultra160 SCSI to PCI Host Adapters October 2001 Version 1.1 ® DB15-000183-01 Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic.
    [Show full text]
  • Megaraid Adapters Host Bus Adapters LSI Logic Distribution
    LSI Logic Distribution Product Guide MegaRAID Adapters Host Bus Adapters Powerful Information Protection Whether you’re an IT professional or an OEM, you can depend on LSI Logic to deliver the standard storage solutions you need. Our innovative storage products include I/O controllers, SCSI and Fibre Channel Host Bus Adapters (HBAs), and LSI Logic Product Highlights RAID storage adapters, all designed to give • Industry's first shipping PCI SCSI RAID storage adapter you the performance, reliability, efficiency with Ultra320 SCSI support. 4 and availability your application demands. • First six-channel Serial ATA RAID solution now sampling. .7 As the global leader in the standard storage • Powerful processor-based and software assisted ATA industry, LSI Logic supports customers the RAID solutions. 8 world over, with market-leading SCSI, serial • 2 Gbit Fibre Channel host bus adapters set the ATA and Fibre Channel technology. Our long- performance standard. 9 term stability, expertise and commitment to • LSI Logic Ultra320 SCSI controllers first to full production, innovation ensure that you’ll always benefit now shipping in volume . .10 from the latest technology, backed by the • Value Line host bus adapters -- Same high-performance solid foundation that only an industry leader SCSI HBAs -- at dramatically reduced prices . .12 like LSI Logic can promise. Advanced Controllers & HBAs For more than 20 years, LSI Logic has provided industry-leading storage solutions to major OEMs, such as Compaq, Sun Microsystems, Hewlett-Packard and Intel. Thanks to our success with these programs, we can now deliver multi-platform, innovative, quality products for your applications, as well. Leading LSI Logic technologies include the evolving SAS interface and our exclusive Fusion-MPTTM architecture.
    [Show full text]
  • NCR 53C700/53C700-66 SCSI 1/0 Processor Data Manual
    NCR 53C700/53C700-66 SCSI 1/0 Processor Data Manual The product(s) described in this publication is a licensed product of NCR Corporation. TolerANT and SCSI SCRIPTS are registered trademarks of NCR Corporation. It is the policy of NCR Corporation to improve products as new technology, components, software, and firmware become available. NCR Corporation, therefore, reserves the right to change specifications without notice. NCR products are not intended for use in life-suppott appliances, devices, or systems. Use of an NCR product in such applications without the written consent ofthe appropriate NCR officer is prohibited. For information on updates to this or other NCR products, contact the NCR Microelectronic Products Division electronic bulletin board at (719) 596-1649. Copyright ©1993 By NCR Corporation Dayton, Ohio U.S.A. All Rights Reserved Printed in U.S.A. c Preface SCSI Specifications This manual assumes some prior knowledge of current and proposed SCSI standards. For background information, please contact: ANSI 11 West 42nd Street New York, NY 10036 (212) 642-4900 Ask for document number X3.131-1986 (SCSI-I) Global Engineering Documents 2805 McGaw Irvine, CA 92714 (800)-854-7179 or (714) 261-1455 .? Ask for document number X3.131-199X (SCSI-2) ENDL Publications 14426 Black Walnut Court Saratoga, CA 95070 (408) 867-6642 Document names: SCSI Bench Reference, SCSI Encyclopedia Prentice Hall Englewood Cliffs, NJ 07632 (201) 767-5937 Ask for document number ISBN 0-13-796855-8, SCSI: Understanding the Small Computer System Inter­ face NCR Microelectronic Products Division Electronic Bulletin Board (719) 596-1649 The SCSI Electronic Bulletin Board (719) 574-0424 NCR 53C700/53C700-66 Data Manual Revision Record Page No.
    [Show full text]
  • LSI21003 PCI to Dual Channel SCSI Host Adapter User's Guide
    User’s Guide LSI21003 PCI to Dual Channel SCSI Host Adapter Version 1.0 October 2000 ® S14051 Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic.
    [Show full text]
  • PCI Express Basics & Background
    PCI Express® Basics & Background Richard Solomon Synopsys Copyright © 2014, PCI-SIG, All Rights Reserved 1 Acknowledgements Thanks are due to Ravi Budruk, Mindshare, Inc. for much of the material on PCI Express Basics PCIe Technology Seminar Copyright © 2014, PCI-SIG, All Rights Reserved 2 Agenda . PCI Express Background . PCI Express Basics . PCI Express Recent Developments PCIe Technology Seminar Copyright © 2014, PCI-SIG, All Rights Reserved 3 PCI Express Background PCIe Technology Seminar Copyright © 2014, PCI-SIG, All Rights Reserved 4 Revolutionary AND Evolutionary . PCI™ (1992/1993) Revolutionary – Plug and Play jumperless configuration (BARs) – Unprecedented bandwidth • 32-bit / 33MHz – 133MB/sec • 64-bit / 66MHz – 533MB/sec – Designed from day 1 for bus-mastering adapters Evolutionary – System BIOS maps devices then operating systems boot and run without further knowledge of PCI – PCI-aware O/S could gain improved functionality – PCI 2.1 (1995) doubled bandwidth with 66MHz mode PCIe Technology Seminar Copyright © 2014, PCI-SIG, All Rights Reserved 5 Revolutionary AND Evolutionary . PCI-X™ (1999) Revolutionary – Unprecedented bandwidth • Up to 1066MB/sec with 64-bit / 133MHz – Registered bus protocol • Eased electrical timing requirements – Brought split transactions into PCI “world” Evolutionary – PCI compatible at hardware *AND* software levels – PCI-X 2.0 (2003) doubled bandwidth • 2133MB/sec at PCI-X 266 and 4266MB/sec at PCI-X 533 PCIe Technology Seminar Copyright © 2014, PCI-SIG, All Rights Reserved 6 Revolutionary AND Evolutionary . PCI Express – aka PCIe® (2002) Revolutionary – Unprecedented bandwidth • x1: up to 1GB/sec in *EACH* direction • x16: up to 16GB/sec in *EACH* direction – “Relaxed” electricals due to serial bus architecture • Point-to-point, low voltage, dual simplex with embedded clocking Evolutionary – PCI compatible at software level • Configuration space, Power Management, etc.
    [Show full text]
  • Industrial I/O Solutions 12-1
    Table of Contents / Industrial I/O Solutions 12-1 12 Industrial I/O Solutions 12-4 DAQ-Embedded Computers 12-5 Analog I/O and Multifunction Cards 12-9 Digital I/O and Multifunction Cards 12-15 USB I/O Modules and USB Hubs 12-18 Signal Conditioners and Terminal Boards 12-21 Serial Communication Cards 12-2 Product Introduction Advantech Data Acquisition and Control Solutions As a leading supplier of data acquisition products worldwide, Advantech offers a wide range of I/O devices with various interfaces and functions based on PC technology, from legacy ISA to modern USB and from signal-conditioning to graphical software tools. Advantech’s industrial I/O products are reliable, accurate, affordable, and suitable for many industrial automation applications (e.g., testing and measurement) and laboratory applications (e.g., monitoring, control, machine automation, and product testing). Signal Sensing Signal Conditioning Data Acquisition Signal Conditioners Embedded Computers Advantech’s signal conditioners provide sensor MIC-1800 series units are standalone embedded and signal conditioning on a per-module basis for computers with integrated data acquisition modules various types of sensors or signals. and signal conditioning to provide digital I/O, analog I/O, and counter functions. The palm-sized design with built-in terminals is suitable for space-limited applications. I/O Wiring Terminal Boards SuperSpeed USB 3.0 I/O Modules Equipment Sensor I/O wiring terminal boards offer convenient and SuperSpeed USB 3.0 I/O modules can be leveraged reliable signal wiring for a wide range of Advantech for a diverse range of industrial control applications.
    [Show full text]
  • SCSI, the Nuts and Bolts
    SCSI, thE Nuts and Bolts . • • • • I • • • • • • • • • • • • • • . - • • • • ZADIAN TECHNOLOGIES • Welcome Notes Welcome to the Zadian seminar. Please locate in the following pages of t:l!S book: 1. Copyright Notice 2. Disclaimer Notice 3. Information about Zadian products and services 4. Table of Content~;s In the back of the book, you will find ar, j:1ds}( with subjects and pa~.:e numbers. We hope that you will f1nd t;18 course informative, h0~~rul, and enjuy-ab;...,. ,.~ ~ II'~ • Z .. "J.FJr. Ii .,'j I :(" adtan ~L'.fU not.)LJ ares, nv~ 1210 S. 8asconl Pi ',s., t:214 San Jose, f'A !35", 28 Tel: (408) 293-0800 Fax: (408) 293-0850 Zatfian 'IeclinoCogies Octo6er 1, 1992 Copyright Copyright © 1988, 1989, 1990, 1991, 1992, Zadian Technologies, Inc. A" rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Zadian Technologies, Inc. Zatfian'Iecfinofogies Octo6er 1, 1992 I Disclaimer This material is not a specification for SCSI or any other system. Zadian Technologies makes no warranty and assumes no liability arising out of the application or use of any product, hardware, software, system, circuit, or anything else described herein. Zadian Technologies assumes no responsibility for errors appearing in this docu­ ment. Zadian Technologies assumes no responsibility for any claims that the concepts or details discussed in the seminar, or disclosed in the course materials, are pro­ prietary to any person or company. Seminar participants are urged to clear any designs proposed for products with their patent and copyright council.
    [Show full text]