LSI22903 Ultra160 SCSI Mini-HBA Product Brief

Total Page:16

File Type:pdf, Size:1020Kb

LSI22903 Ultra160 SCSI Mini-HBA Product Brief LSI22903 LSI22903 MINIHAB HOST SCSIADAPTER Host Adapter KEY APPLICATIONS • Servers, Internet/Intranet, network, video, e-mail, printing, database management • Workstations, CAD/CAM, The LSI22903 dual channel Ultra160 SCSI MiniHAB™ host adapter. industrial simulation • Host Attach for RAID and JBOD DUAL-CHANNEL ULTRA160 SCSI MINIHAB HOST ADAPTER mass storage subsystems— DESIGNED FOR 1U AND 2U HIGH RACKABLE SERVERS anywhere data access is the The LSI22903 is a dual-channel Ultra160 SCSI host adapter based on bottleneck the Low Profile PCI form factor is designed for low profile rack mounted servers. The LSI22903 host adapter provides two independent Ultra160 SCSI channels PCI INTERFACE offering increased connectivity without utilizing additional PCI slots. The • 64-bit or 32-bit, 66 MHz external channels support LVD and single-ended SCSI while the internal PCI interface channel support LVD SCSI. • Maximum burst rate of 528 MBps The LSI22903 leverages the LSI53C1010 PCI dual-channel Ultra160 • 64-bit addressing (DAC) support SCSI controller. The single-chip, true multi-function PCI device connects directly to a 64-bit or 32-bit PCI bus. This presents one electrical load, while functioning • PCI 2.2, PCI Power Management as a single 64-bit or 32-bit PCI DMA bus master. 1.1, and PC99 compliant The LSI22903 includes an easy-to-use on-board configuration utility, • Compliant to PCI Hot Plug which allows the viewing and changing of default configuration settings for electrical specification the host adapter and SCSI devices. PCI Bus: OVERVIEW 64-bit or 32-bit, 66 MHz PCI Figure 1 shows the major components on the LSI22903 host adapter. SCSI Bus: 16-bit, LVD or SE 6.6" External LED SCSI Performance: Connector 68 pin High-Density SCSI Connector Channel B Fast, Ultra, Ultra2, Ultra160 A Terminators FLASH BIOS SCSI Connector Config: Oscillator B Terminators 2.53" A Terminators LSI53C1010 68-pin VHDCI Internal: 68-pin HD SCSI Connector LSI22903 External: 68-pin HD VHDCI Max No of SCSI Devices: 64-bit Universal PCI Bus Connector 30 Figure 1: LSI22903 host adapter diagram LSI22903 SCSI Host Adapter SCSI INTERFACE LSI53C1010 • Two independent Wide Ultra160 The LSI53C1010 dual-channel Ultra160 controller contains the PCI and SCSI Channels SCSI functionality for the LSI22903 Host Adapter Board. The host PCI interface implements a 64-bit/66 MHz PCI bus. It is backward compatible with 32-bit/33 • Supports 160 MBps SCSI MHz buses. Additionally support is provided for Dual Address Cycle (DAC), PCI per channel power management, Subsystem Vendor ID and Vital Product Data (VPD). • Fully compliant with Extended access cycles (MRL, MRM, MWI) are also supported. The imple- Ultra160 initiative mentation is PCI 2.2 compliant. CONNECTORS SureLINK™ Domain Validation • 68-pin high density for internal During the introduction of our Ultra160 SCSI products, SureLINK domain connection validation made its debut. Available exclusively from LSI Logic, this advanced technology detects the configuration of the SCSI bus and automatically tests • 68-pin VHDCI for external and adjusts the SCSI transfer rate to optimize interoperability. SureLINK connection technology exceeds Ultra160 by providing not only Basic (Level 1) and Enhanced (Level 2) domain validation, but adds Margining (Level 3) domain • Supports fast, Ultra, Ultra2 SCSI validation. This enhancement margins LVD drive strength and clock signal and Ultra160 timing characteristics to identify marginal Ultra160 systems. BOARD CHARACTERISTICS Flash Memory • Universal, 64-bit PCI The LSI22903 board provides up to 128K x 8 flash memory device for edge connector storing the SCSI BIOS. • Board Size: 6.6 “ x 2.53 “ Serial EEPROM • Bracket: low profile PCI or The LSI22903 has a 16K x 1bit serial EEPROM memory device for storing ISA/EISA style the configuration information for each channel. The SDMS™ software will utilize this device automatically. TERMINATION • Software termination Termination enable/disable Active termination is provided on the LSI22903. Termination can be automatically enabled or disabled for each SCSI channel via • Universal (SE/LVD ) termination configuration utility. on external channel and LVD on internal channel 2 Environmental Specifications VISUAL INDICATOR • Size: 6.6” x 2.53” • SCSI bus active 4-pin header for off-board channel A and B • Electrical: 5V ±5% (3.0 A max) 3.3V ±5% LEDs • PCI Maximum Power Dissipation: 7.5 Watts SOFTWARE SUPPORT • Operating temperature range: +5°C to +55°C • NT 4.0 SP4, Windows 2000 • Relative Humidity: 5% to 90% non-condensing • NetWare 4.11 & 5.0 • Maximum dew point temperature: +32°C • UnixWare 2.12 & 7.X WARRANTY • Solaris 2.6, 2.7, 2.8 - X86 For more than 15 years, LSI Logic host adapters have been providing high- • Linux 2.2 and 2.4 performance SCSI solutions to leading server, disk array and computer systems • Fully supported in SDMS worldwide. Each host adapter carries a powerful chip built in LSI Logic’s ISO release 4.6 9001-certified fabrication facilities. Using only the highest quality components, LSI Logic host adapters are assembled and tested in world-class facilities to • Server management support assure superior product reliability and performance. Because of stringent for DMI 2.0 quality management programs, our host adapters carry a five-year limited – NT 4.0, NetWare 4.11, warranty. UnixWare 2.12 – Snap-in Java browser UTILITIES • Install and BIOS upgrade utility • SCSI format • Configuration utility CERTIFICATION • PC98/99 compliant • Microsoft cluster server tested 3 LSI22903 SCSI Host Adapter ABOUT LSI LOGIC For more information please visit LSI Logic Corporation (NYSE: LSI) is a leading designer and manufacturer the LSI Logic web site at: of communications and storage semiconductors for applications that access, http://storageio.lsilogic.com interconnect and store data, voice and video. In addition, the company supplies LSI Logic Corporation storage network solutions for the enterprise. LSI Logic is headquartered at North American Headquarters 1551 McCarthy Boulevard, Milpitas, CA 95035, 408-433-8000, Milpitas, CA http://www.lsilogic.com. Tel: 866 574 5741 Host Adapter Group Southborough, MA Tel: 888 429 0425 FAX: 508 485 0303 LSI Logic Europe Ltd. European Headquarters United Kingdom Tel: 44 1344 426544 Fax: 44 1344 481039 LSI Logic KK Headquarters Tokyo, Japan Tel: 81 3 5463 7165 Fax 81 3 5463 7820 ISO 9000 Certified The LSI Logic logo design, SDMS, SureLINK, and VERITAS Volume Manager are trademarks or registered trademarks of LSI Logic Corporation. All other brand and product names may be trade- marks of their respective companies. LSI Logic Corporation reserves the right to make changes to any products and services herein at any time without notice. LSI Logic does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by LSI Logic; nor does the purchase, lease, or use of a product or service from LSI Logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic or of third parties. Copyright ©2001 by LSI Logic Corporation. All rights reserved. Order No. S20019 10/01-1M – Printed in USA 4.
Recommended publications
  • HP A5150A PCI Dual Port Ultra2 SCSI Host Bus Adapter
    HP A5150A PCI Dual Port Ultra2 SCSI Host Bus Adapter Service and User Guide Edition 2 Customer Order Number: A5150-90001 Manufacturing Part Number: A5150-96002 E0201 U.S.A. © Copyright 2001, Hewlett-Packard Company. Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty. A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your local Sales and Service Office. Restricted Rights Legend. Use, duplication or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies. HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto, California 94304 U.S.A. Use of this manual and flexible disk(s) or tape cartridge(s) supplied for this pack is restricted to this product only. Additional copies of the programs may be made for security and back-up purposes only. Resale of the programs in their present form or with alterations, is expressly prohibited.
    [Show full text]
  • AVA™-2902E/I PCI SCSI Host Adapter with External Or Internal SCSI Connector
    R AVA™-2902E/I PCI SCSI Host Adapter with External or Internal SCSI Connector OVERVIEW Support for the AVA-2902E/I adapters are embedded in Windows® 95 and The Adaptec AVA™-2902E/I host Windows NT™ and support for MS- adapters offer highly-compatible DOS® and Windows® 3.1x is available PCI-to-SCSI connectivity for non- through drivers which assure compati- booting peripherals such as scanners, bility with these desktop operating CD-recordable drives, removable systems. drives, and digital cameras. The AVA-2902E/I adapters provide PCI SCSI performance for use with IBM- Adaptec has developed strong rela- compatible PCs. For peripheral tionships with ISHVs (Independent OEMs who are looking for a PCI Software Hardware Vendors) to SCSI solution, Adaptec offers industry maximize product compatibility with standard host adapters, based on industry leading hardware and soft- proven designs. ware products. These relationships mean reduced technical support due KEY BENEFITS to increased compatibility, resulting in lower total cost of ownership. PRODUCT HIGHLIGHTS Simple to Install and Easy to Use • Industry standard SCSI PCI is inherently easy to use. Proven Quality and Reliability architecture for unmatched Plug-and-Play technology makes The AVA-2902E/I host adapters compatibility installations virtually automatic with have undergone thorough testing in no jumpers or switches to configure. • Plug-and-Play – no jumpers or Adaptec’s Product Test Laboratory. The Adaptec AVA-2902E/I adapters switches to configure, lowers Each board design is subjected to are based on industry-standard archi- technical support costs thousands of hours of functional, tecture to help OEMs reduce technical compatibility, and environmental • 32-bit PCI bus master for low support calls.
    [Show full text]
  • Ultra160 SCSI to PCI Host Adapters User Guide
    USER’S GUIDE Ultra160 SCSI to PCI Host Adapters October 2001 Version 1.1 ® DB15-000183-01 Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic.
    [Show full text]
  • Megaraid Adapters Host Bus Adapters LSI Logic Distribution
    LSI Logic Distribution Product Guide MegaRAID Adapters Host Bus Adapters Powerful Information Protection Whether you’re an IT professional or an OEM, you can depend on LSI Logic to deliver the standard storage solutions you need. Our innovative storage products include I/O controllers, SCSI and Fibre Channel Host Bus Adapters (HBAs), and LSI Logic Product Highlights RAID storage adapters, all designed to give • Industry's first shipping PCI SCSI RAID storage adapter you the performance, reliability, efficiency with Ultra320 SCSI support. 4 and availability your application demands. • First six-channel Serial ATA RAID solution now sampling. .7 As the global leader in the standard storage • Powerful processor-based and software assisted ATA industry, LSI Logic supports customers the RAID solutions. 8 world over, with market-leading SCSI, serial • 2 Gbit Fibre Channel host bus adapters set the ATA and Fibre Channel technology. Our long- performance standard. 9 term stability, expertise and commitment to • LSI Logic Ultra320 SCSI controllers first to full production, innovation ensure that you’ll always benefit now shipping in volume . .10 from the latest technology, backed by the • Value Line host bus adapters -- Same high-performance solid foundation that only an industry leader SCSI HBAs -- at dramatically reduced prices . .12 like LSI Logic can promise. Advanced Controllers & HBAs For more than 20 years, LSI Logic has provided industry-leading storage solutions to major OEMs, such as Compaq, Sun Microsystems, Hewlett-Packard and Intel. Thanks to our success with these programs, we can now deliver multi-platform, innovative, quality products for your applications, as well. Leading LSI Logic technologies include the evolving SAS interface and our exclusive Fusion-MPTTM architecture.
    [Show full text]
  • LSI21003 PCI to Dual Channel SCSI Host Adapter User's Guide
    User’s Guide LSI21003 PCI to Dual Channel SCSI Host Adapter Version 1.0 October 2000 ® S14051 Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic.
    [Show full text]
  • SCSI, the Nuts and Bolts
    SCSI, thE Nuts and Bolts . • • • • I • • • • • • • • • • • • • • . - • • • • ZADIAN TECHNOLOGIES • Welcome Notes Welcome to the Zadian seminar. Please locate in the following pages of t:l!S book: 1. Copyright Notice 2. Disclaimer Notice 3. Information about Zadian products and services 4. Table of Content~;s In the back of the book, you will find ar, j:1ds}( with subjects and pa~.:e numbers. We hope that you will f1nd t;18 course informative, h0~~rul, and enjuy-ab;...,. ,.~ ~ II'~ • Z .. "J.FJr. Ii .,'j I :(" adtan ~L'.fU not.)LJ ares, nv~ 1210 S. 8asconl Pi ',s., t:214 San Jose, f'A !35", 28 Tel: (408) 293-0800 Fax: (408) 293-0850 Zatfian 'IeclinoCogies Octo6er 1, 1992 Copyright Copyright © 1988, 1989, 1990, 1991, 1992, Zadian Technologies, Inc. A" rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Zadian Technologies, Inc. Zatfian'Iecfinofogies Octo6er 1, 1992 I Disclaimer This material is not a specification for SCSI or any other system. Zadian Technologies makes no warranty and assumes no liability arising out of the application or use of any product, hardware, software, system, circuit, or anything else described herein. Zadian Technologies assumes no responsibility for errors appearing in this docu­ ment. Zadian Technologies assumes no responsibility for any claims that the concepts or details discussed in the seminar, or disclosed in the course materials, are pro­ prietary to any person or company. Seminar participants are urged to clear any designs proposed for products with their patent and copyright council.
    [Show full text]
  • Fastscsi Product Overview Product Brief ASC3030 ASB3922 ASB3925 the Fast SCSI Solution from Advansys Has High Performance and Affordability Built-In
    ä Performance Connectivity… FastSCSI Product Overview Product Brief ASC3030 ASB3922 ASB3925 The Fast SCSI solution from AdvanSys has high performance and affordability built-in. Our ASC3030 is a single-chip, highly integrated Fast SCSI controller designed specifically for interfacing the Peripheral Component Interconnect (PCI) bus to the SCSI bus. We use a patented architecture utilizing an application specific RISC engine and integrated memory to yield high performance yet cost effective Fast SCSI products. ASC3030 FAST SCSI CHIP Product Highlights All handshakes with the SCSI peripheral devices are managed by an advanced Reduced Instruction Set Computing (RISC) engine. Through PCI bus mastering, the ASC3030 transfers data between the SCSI devices and the main system memory at the maximum possible speed of the PCI bus (bursts to 133 MB/s) with no intervention from the host CPU. Multi-threading capability allows the ASC3030 to process up to 20 data requests simultaneously to minimize SCSI bus idle time. For SCSI-1 devices, there can only be one outstanding request on each device. For SCSI-2 devices with multiple outstanding requests (queuing of multiple commands), the ASC3030 provides an I/O throughput several times that of a single-threaded SCSI chip. FEATURE BENEFITS 128-pin PQFP package Makes for more economical board layout Polarity of SCSI Terminator Enable Allowing for multiple terminator vendors is programmable Power management: the RISC/SCSI Reduce power consumption circuitry clock can be shut off Auto-termination Automatic configuration
    [Show full text]
  • PCI SCSI Host Adapters
    JANUARY 2001 IC511C IC512C IC513C IC514C PCI SCSI Host Adapters CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 INFORMATION Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected] FCC/IC RFI STATEMENTS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO-FREQUENCY INTERFERENCE STATEMENTS Class B Digital Device. This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or telephone reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    [Show full text]
  • Ultra Wide SCSI-2 LVD Host Adapter SE LVD TERM ACT SE LVD
    AUGUST 1999 IC515C Ultra Wide SCSI-2 LVD Host Adapter SE LVD TERM ACT SE LVD CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 INFORMATION Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected] FCC/IC STATEMENTS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS Class B Digital Device. This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or telephone reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    [Show full text]
  • Ultra320 SCSI Card, Host Bus Adapter
    Ultra320 SCSI Card, Host Bus Adapter SCSI Host Bus Adapter - P79320 ● 320 MByte/second throughput ● Multimode LVD/MSE/SE ● 32-or 64-bit (up to 133 Mhz) DMA bus master PCI, PCI-X ● Supports SCSI-1, Fast SCSI, Ultra, Ultra2, Ultra3 (U160), Ultra4 (U320) ● Auto Termination ● SureLINK™, LVDlink™, TolerANT™ ● Supports SCSI Boot Drive Paralan's Ultra320 SCSI Host Bus Adapter is ideal for high-end workstations, servers, and power users. The P79320 is a very easy-to-install SCSI solution. Complete software tools are provided and there are no jumpers or switches to set for a standard installation. The termination programming is automatic. The P79320 features seamless backward compatibility with Asynchronous, Slow, Fast, Ultra, Wide Ultra, Ultra2 and Ultra3 devices. Your satisfaction is assured by Paralan - the world's #1 choice for SCSI enhancement products. High-performance, 320 MBytes/s Host Bus Adapter, ideal for high-end workstations, servers, and power users. Features seamless backward compatibility with Asynchronous, Slow, Fast, Ultra, Wide Ultra, Ultra2 and Ultra3 devices. The P79320 incorporates the LSI 53C1020 controller which provides many benefits including: SureLINK™ is the control for Ultra320 SCSI Domain Validation manageability enhancements in the LSI 53C1020. This is the very latest SCSI interconnect management solution. It verifies that the system is capable of transferring data at Ultra320 speeds, allowing it to negotiate to lower speed and bus width if necessary. LVDlink™ Technology Benefits The P79320 supports LVD, a signaling technology that increases reliability of SCSI data transfers over longer distances than are supported by Single-ended (SE) SCSI. The low power requirement of LVD allows the I/0 transceivers to be integrated directly onto the ASIC.
    [Show full text]
  • LSI8751D SCSI Host Adapter
    LSI8751D SCSI Host Adapter KEY APPLICATIONS • High-performance servers, clustered systems, workstations • Intersystem connections - server and workstation to RAID and JBODS, and network management • Adding Ultra SCSI hard drives The LSI8751D PCI-to-Fast/Ultra Wide Differential SCSI host adapter combines to servers, workstations, RAID Ultra SCSI data transfer rates with reliable data integrity. and JBODs • Upgrading existing Fast SCSI OVERVIEW hard disk systems to Ultra-level The LSI8751D host adapter combines Ultra SCSI data transfer rates with the performance, while supporting reliable data integrity of High Voltage Differential (HVD) signaling and the legacy SCSI devices high performance PCI system bus. The LSI8751D supports 16-bit SCSI-1 and -2 (Fast) devices as well as Ultra SCSI devices. As part of the LSI Logic Bus Interface: brand of host adapters built around the LSI53C875 PCI-SCSI controller, the 3/5V PCI LSI8751D shares a common BIOS and operating system driver set. PCI Mode: Up to 15 other SCSI devices may be connected internally and/or externally. Bus Master The PCI bus provides Plug-and-Play with no jumpers, switches, IRQs, system Plug-and-Play: DMA or addresses to budget, making installation a matter of plugging in Yes the host adapter, setting the termination and loading the drivers. SCSI Rate: The LSI8751D does not shrink the entire SCSI bus performance to the slowest 40 MBps synchronous device on the bus. Whether you are connecting SCSI, Fast or Ultra SCSI 14 MBps asynchronous devices, the LSI8751D matches its transfer rates to the highest rate of each SCSI Bus: device on the bus.
    [Show full text]
  • SCSI PCI Card 20 Mbytes/Sec Ultra SCSI PCI Controller Card
    SCSI PCI Card 20 MBytes/sec Ultra SCSI PCI Controller Card PCISCSI2U Instruction Manual Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which this manual applies by the third-party company in question.
    [Show full text]