POLLUTION CONTROL BOARD (0721) "Sahakar Surabhi" Bapatwadi Near Vivekanand i Phone 2563592 Colony - 444606 Fax (0721) 25635e7 siilAl{Asir)xA Email roamravati@mpcb. gov.in WW Visit At h tt tl : //rn pc]r,.eor'. i n

Red/S.S.I Consent No; MPCB/1 6/1 609000466 Date:20/0912016

Consent to Operate under Section 26 of the Water (Prevention & Control of Pollution) Act, 1974 & under Section 21 of the Air (Prevention & Control of Pollution) Act, 1981 and Authorization / Renewal of Authorization under Rule 5 of the Hazardous Wastes (Management, Handling & Transboundry Movement) Rules 2016

[To be referred as water Act, Air Act and HW (M&H) Rules respectively].

CONStrNT is hereby granted to M/s. Metal Works S. No.5/1,Kinhi,Tq. Karanja Lad,D ist.

located in the area declared under the provisions of the Water Act, Air act and Authorization under the provisions of I{W(N{&H) Rules and amendments thereto subject to the provisions of the Act and the Rules and the Orders that may be made further and subject to the follorving terms and conditions:

r.The Consent to Operate is granted for a period up to: 31.07.20L9 2. The Consent is valid for the manufacture of -

(Without surface treatment Galvanizing, Anodizing, Phosphating and

3" CONDITIONS UNDER WATER ACT: (i) The daily quantity of tlade effluent ftour the factorv shall be NIL (ii) The daily quar-riity of seu,age effluenf fi'onl the factory shall not exceed 0.

iii) iv) Tra.de Efflue[t Disposal :- ...N.A...

v) Selvas.e Ffqq,gIt,'[reatqgnt :-'fhe applicant shall provide comprehensive treatment systern as is rvarranted witli reference to int-luent quality and operate and maintain the same continuously so as to achieve the quality of treated to the followirrg standards. Suspended Solids Not to exceed 100 rng/l B.O.D. 3 days 27 0C -do.

vi) Seyaeq Etfl-qeTt Qiqlqsal :-Treated donrestic eff'ltrent shall be soaked irr a soak pit, which shall be got cleaned periodically. Overtlow" if any" shall be used en land fbr plantation only. t-

vii) Non-Hazardous Solid Wastes:

...... N. A...... I viii) gonrtirions i \ 9ther :- of i nd ustrv,derre4 d! ne u non o noe.rap h ica I f lffi res of a rea. I l 4. The applicant shall comply with the provisions of the water (Prevention poilution) & control of cess Act, L977 (to be referred as Cess Act) and amendment Rules, 2003 there under The daily water consumption for the folrowing categories is as under: (i) Domestic pul'pose 1.00 CN{I) (ii) Water gets Polluted & Pollutants are Riodegladable 0.00 cMI) (iii) Water gets Pollutod, pollutants are not l3iodegradable & ll.oxic ... 0.00 ctMD (ir) Indtrstr.ial Cooling, spi,trying in mine pits or boiler: feed 1.00cN,,fll The applicant shnll r.egular.l1. subrnit to the Boirt,cl the leturns of rvatel consumption in the prescnbed folrn ancl pay the Cess as specified under Section 3 of the said Act.

5" CONDITIONS UNDER AIR ACT : (i) The applicant shall install a comprehensive control system consisting of control equipments as is warranted with reference tn generation of emission and operate and mainlain the same continuously so as to achieve the level of pollutants to the following standards: a. Control Equipment: The dust collection system provided to coating section should be operated & maintained properly so as to bring the air pollutants with 6. Standards for Stack Emissions: i) SPM/TPM Not to exceed 150 rns/NMJ ii) SO2 Not to exceed

The a icant shall observe the followin fuel attern:- Sr. No. TypeOfFuel UOM

Furnace Oil Ltrs/da ..N.A.... (i) The applicant shall erect the chimney(s) of the following S ifrcations:-

Melting Furnace A!nealing Furnace

(ii) The applicant shall provide ports in the chimney/(s) and facilities such as ladder, platform etc. for monitoring the air emissions and the same shall be open for inspection toiand for use of the Boarcl's staff. The chimney(s) vents attached to valiotts sotu'ces ol ernissior"r shall be desigr-ratecl by-nLrmbeis such as s-1, s-2, etc. and these shall be paintecl/ displayed to facilitate identification. ;--\ (iil) The industry shall take adeqr.rate rneasures for control of noise levels Its from o\\'n soLtrces within the prernises so as to maintain ambient air quality ::andat'd in respect of noise to less than 75 clB(A) dr-rring day time and 70 :B -\) during night tirne. Da1' tirne is recl

(ii) Treatrlet-it:

1' The atrthorization is hereby granlecl to operate a facility for collection, stolage, transport & disposal of hazar.dor.rs rvaste. 8' \\'henever dtre to any accident ol gas leakage or.other trnforeseen act or even, such emissions occllr or is apprehendecl to occur in excess of standards laict down, such informatiot] shall forthn'ith Reported to Collector, Directorate of Industry, Safety and Health, Police.be Station, Fire Brigade, Directorate of Health Services, Department of Explosives, Boat'd and Local Body and the production process should be stopped by taking all necessary safety -urr.,ru.. The industry sfrait also monitor the emission and ensure that the emissions do not cause any harm or nuisance in the surrounding. The indr-rstry should not restart the process without permission the of Board and other statutory organization as reqtrire nnder the lalv.

9. Industry shall comply with following additional conditions: i' The applicant shall maintain goocl housel

(n.Snwa"kh6de) Regional Officer

To, M/s. Vidarbha Metal Works S.No. 5/l,Kinhi,Tq.Karanja Lad,Dist'Washim

Received Consent fee of -

Copy to: SRO, l\,tP CB, Amravati- II