710 Series Process Calibrators Technical Data

Compact, lightweight, and easy to carry The Fluke 710 Series Process Cali- • Simulate additional RTDs brators offer a clear new choice in using Ohms source function single-function calibrators. These • °F or °C selectable handheld calibrators deliver out- Four shrouded banana jacks standing performance, durability • and reliability. Offered in the rugged 714 Thermocouple Fluke 80 Series DMM package, the Calibrator calibrators are compact, lightweight, Measure temperature from TC and easy to carry. With a push- • output button interface similar to the multifunction Fluke 740 Series • Simulate TC output Documenting Process Calibrators, • Operable with nine types of the 710s are easy to use. Each thermocouples calibrator is EMI tolerant, dust and • Calibrate linear TC transmitter splash-resistant, and features a with mV source function removable battery door for quick Selectable °F or °C battery changes. • • Thermocouple mini-jack General features termination • Compact and lightweight • Available as accessories: • Simple controls • Fluke 700 TC1 and TC2 • Clear, 5-digit, display • Thermocouple Mini-plug Kits • Operating temperature: 715 Volt/mA Calibrator 10°C to 55°C • Measure loop current (0-20 mA, • Safety: CSA C22.2 No. 4-20 mA) signals with 0.01 % 1010.1:1992 accuracy and 0.001mA resolution • Three-year warranty • Measure voltage output process • Included: signals from PLCs, transmitters • Fluke 710 Process Calibrator • Source or simulate 24 mA loop • Protective yellow holster with current test lead holder • Source voltage to 100 mV or 10V • Test leads and alligator clips • 24V loop supply with simultane- (excluding Model 714) ous current measurement • Single 9V alkaline battery 717-30G and 717-100G (two in 718) Pressure Calibrator • Instructions (14 languages) • Measure pressure, 0.05 % of full scale with internal 30 psig 712 RTD Calibrator or 100 psig sensor Measure temperature from • 1/8 NPT pressure fitting RTD output • Compatible with non-corrosive Simulate RTD output • • gasses and liquids Rosemount pulsed RTD • Measure pressure to 10,000 transmitter compatible • psi/69 mPa using one of 27 • Operates with seven types Fluke 700Pxx Pressure Modules of RTDs • Measure mA with 0.025 % accu- • Measure additional RTDs using racy and 0.001 mA resolution, Ohms measurement function while sourcing 24 V loop power • Pressure switch test 718-30G and 718-100G • Rugged and reliable, ideal for General Specifications field use 716 Pressure Calibrator Pressure Calibrator Maximum voltage: 30 volts: Non-operating Intrinsically safe version available • Measure Pressure to 10,000 temperature: -4 0 °C to 60 °C Operating temperature: -10 °C to 55° C Built-in pressure / vacuum psi/69 mPa using one of 29 • Fluke 700Pxx Pressure Modules Relative humidity: 95 % (10 °C to 30 °C); hand pump, with vernier and 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); bleed valve • Measure mA with 0.025 % accu- 35 % (50 °C to 55 °C) Operating altitude: 3,000m max Pressure measurement to 0.05 % racy and 0.001 µA resolution, • while sourcing 24V loop power Shock: 1m drop test of full span, using an internal Vibration: Random, 2g, 5-500 Hz pressure sensor • Calibrate P/I or I/P transmitter Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022:1994 Pressure measurement to with simultaneous pressure and • current measurement Class B 10,000 psi/700 bar using any Size/weight, (712-717 with holster): of the Fluke 700Pxx Pressure • Select from 11 different 201mm L x 98 mm W x 52 mm D (7.93 in L x Modules engineering units 3.86 in W x 2.06 in D) 600g (21 oz) Size/weight (718): 210 mm L x 83 mm W x • Wide range of selectable meas- • Zero, min, max, and hold 62 mm D (8.25 in L x 3.27 in W x 2.44 in D) urement units for pressure functions 737g (26 oz) Size/weight, (718 with holster): 216 mm L x • Current measurement with 94 mm W x 66 mm D (8.50 in L x 3.72 in W 0.025 % accuracy and 0.001 mA Ordering Information x 2.60 in D) 992g (35 oz) resolution Fluke-712 RTD Calibrator Power: 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 • Pressure switch test Fluke-714 Thermocouple Calibrator Battery Life: 4 to 20 hours, typical, • 24 volt loop power supply Fluke-715 Volt/mA Calibrator depending on functions used Warranty: Three years (one year on pressure Min-Max Hold functions Fluke-717 30G or 100G Pressure Calibrator • Fluke-718 30G or 100G Pressure Calibrator pump in Fluke 718) • Compact size and weight Fluke-718Ex-30G or 100G Inrinsically Safe • Simple, push-button user Pressure Calibrator interface

Specifications (19 ° to 28 °C, one year)

©2004 Fluke Corporation. All rights reserved. Product specifications are subject to change without notice. Printed in U.S.A. 10/2004 2400628 D-ENG-N Rev A