710 Series Process Calibrators Technical Data

710 Series Process Calibrators Technical Data

710 Series Process Calibrators Technical Data Compact, lightweight, and easy to carry The Fluke 710 Series Process Cali- • Simulate additional RTDs brators offer a clear new choice in using Ohms source function single-function calibrators. These • °F or °C selectable handheld calibrators deliver out- Four shrouded banana jacks standing performance, durability • and reliability. Offered in the rugged 714 Thermocouple Fluke 80 Series DMM package, the Calibrator calibrators are compact, lightweight, Measure temperature from TC and easy to carry. With a push- • output button interface similar to the multifunction Fluke 740 Series • Simulate TC output Documenting Process Calibrators, • Operable with nine types of the 710s are easy to use. Each thermocouples calibrator is EMI tolerant, dust and • Calibrate linear TC transmitter splash-resistant, and features a with mV source function removable battery door for quick Selectable °F or °C battery changes. • • Thermocouple mini-jack General features termination • Compact and lightweight • Available as accessories: • Simple controls • Fluke 700 TC1 and TC2 • Clear, 5-digit, display • Thermocouple Mini-plug Kits • Operating temperature: 715 Volt/mA Calibrator 10°C to 55°C • Measure loop current (0-20 mA, • Safety: CSA C22.2 No. 4-20 mA) signals with 0.01 % 1010.1:1992 accuracy and 0.001mA resolution • Three-year warranty • Measure voltage output process • Included: signals from PLCs, transmitters • Fluke 710 Process Calibrator • Source or simulate 24 mA loop • Protective yellow holster with current test lead holder • Source voltage to 100 mV or 10V • Test leads and alligator clips • 24V loop supply with simultane- (excluding Model 714) ous current measurement • Single 9V alkaline battery 717-30G and 717-100G (two in 718) Pressure Calibrator • Instructions (14 languages) • Measure pressure, 0.05 % of full scale with internal 30 psig 712 RTD Calibrator or 100 psig sensor Measure temperature from • 1/8 NPT pressure fitting RTD output • Compatible with non-corrosive Simulate RTD output • • gasses and liquids Rosemount pulsed RTD • Measure pressure to 10,000 transmitter compatible • psi/69 mPa using one of 27 • Operates with seven types Fluke 700Pxx Pressure Modules of RTDs • Measure mA with 0.025 % accu- • Measure additional RTDs using racy and 0.001 mA resolution, Ohms measurement function while sourcing 24 V loop power • Pressure switch test 718-30G and 718-100G • Rugged and reliable, ideal for General Specifications field use 716 Pressure Calibrator Pressure Calibrator Maximum voltage: 30 volts: Non-operating Intrinsically safe version available • Measure Pressure to 10,000 temperature: -4 0 °C to 60 °C Operating temperature: -10 °C to 55° C Built-in pressure / vacuum psi/69 mPa using one of 29 • Fluke 700Pxx Pressure Modules Relative humidity: 95 % (10 °C to 30 °C); hand pump, with vernier and 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C); bleed valve • Measure mA with 0.025 % accu- 35 % (50 °C to 55 °C) Operating altitude: 3,000m max Pressure measurement to 0.05 % racy and 0.001 µA resolution, • while sourcing 24V loop power Shock: 1m drop test of full span, using an internal Vibration: Random, 2g, 5-500 Hz pressure sensor • Calibrate P/I or I/P transmitter Safety: CSA C22.2 No. 1010.1:1992 EMC: EN50082-1:1992 and EN55022:1994 Pressure measurement to with simultaneous pressure and • current measurement Class B 10,000 psi/700 bar using any Size/weight, (712-717 with holster): of the Fluke 700Pxx Pressure • Select from 11 different 201mm L x 98 mm W x 52 mm D (7.93 in L x Modules engineering units 3.86 in W x 2.06 in D) 600g (21 oz) Size/weight (718): 210 mm L x 83 mm W x • Wide range of selectable meas- • Zero, min, max, and hold 62 mm D (8.25 in L x 3.27 in W x 2.44 in D) urement units for pressure functions 737g (26 oz) Size/weight, (718 with holster): 216 mm L x • Current measurement with 94 mm W x 66 mm D (8.50 in L x 3.72 in W 0.025 % accuracy and 0.001 mA Ordering Information x 2.60 in D) 992g (35 oz) resolution Fluke-712 RTD Calibrator Power: 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 • Pressure switch test Fluke-714 Thermocouple Calibrator Battery Life: 4 to 20 hours, typical, • 24 volt loop power supply Fluke-715 Volt/mA Calibrator depending on functions used Warranty: Three years (one year on pressure Min-Max Hold functions Fluke-717 30G or 100G Pressure Calibrator • Fluke-718 30G or 100G Pressure Calibrator pump in Fluke 718) • Compact size and weight Fluke-718Ex-30G or 100G Inrinsically Safe • Simple, push-button user Pressure Calibrator interface Specifications (19 ° to 28 °C, one year) ©2004 Fluke Corporation. All rights reserved. Product specifications are subject to change without notice. Printed in U.S.A. 10/2004 2400628 D-ENG-N Rev A.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us