Blower Packs Installation and Operation Manual Includes Installation, Operation Maintenance and Troubleshooting Information for All Atmospheric Humidifiers

Total Page:16

File Type:pdf, Size:1020Kb

Blower Packs Installation and Operation Manual Includes Installation, Operation Maintenance and Troubleshooting Information for All Atmospheric Humidifiers Important: Read and save these instructions. This guide to be left with equipment owner. Blower Packs Installation and Operation Manual Includes installation, operation maintenance and troubleshooting information for all atmospheric humidifiers 2572641-C2 | 24 Feb 2014 Thank you for choosing Nortec. INSTALLATION DATE (MM/DD/YYYY) MODEL # SERIAL # Proprietary Notice This document and the information disclosed herein are proprietary data of Nortec Humidity Ltd. Neither this document nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Nortec Humidity Ltd. except to the extent required for installation or maintenance of recipient’s equipment. All references to the Nortec name should be taken as referring to Nortec Humidity Ltd. Liability Notice Nortec does not accept any liability for installations of humidity equipment installed by unqualified personnel or the use of parts/components/equipment that are not authorized or approved by Nortec. Copyright Notice Copyright 2015, Nortec Humidity Ltd. All rights reserved. Contents 1 Introduction 2 Receiving and Unpacking 2 Before Installation 3 Humidifier Components 3 RM-BP (Remote Mounted Blower Pack) 4 NH-EL Space 5 Models 6 Installation 6 Typical Installation 7 Location and Mounting 10 Plumbing 11 Electrical 12 Steam Lines 19 Accessories 19 Steam Adapters 20 Blower Pack 21 Startup/Operation 21 Sequence of Operation 22 Maintenance/Service 22 Troubleshooting 23 Spare Parts Introduction CAUTION: Servicing Disconnect main power before any servicing. The plumbing and electrical compartments contain high voltage components and wiring. Access should be limited to authorized personnel only. During and following operation of the humidifier, the steam and components in contact with the steam such as the blower pack, steam lines, steam distributors, and condensate lines can become hot and can burn if touched. Nortec Humidity Ltd does not accept any liability for installations of humidity equipment installed by unqualified personnel or the use of parts/components/equipment that are not authorized or approved by Nortec Humidity Ltd. CAUTION: Electrical All electrical work should be done according to local and national electrical code. Electrical connection to be performed by a licensed electrician. CAUTION: Plumbing Plumbing to be performed by a licensed plumber. Drain water from humidifier and condensate from blower pack can be very hot. Do not drain to public sink. All plumbing work should be done according to local plumbing code. CAUTION: Installation Do not mount on hot surfaces. Do not mount in area where freezing can occur. Do not mount on vibrating surface. Do not mount on floor. 1 | Blower Pack Installation Guide Receiving and Unpacking 1. Check packing slip to ensure ALL material has been delivered. 2. All material shortages are to be reported to Nortec within 48 hours from receipt of goods. Nortec assumes no responsibility for any material shortages beyond this period. 3. Inspect shipping boxes for damage and note damages on shipping waybill accordingly. 4. After unpacking, inspect equipment for damage and if damage is found, notify the shipper promptly. 5. All Nortec products are shipped on an FOB factory basis. Any and all damage, breakage or loss claims are to be made directly to the shipping company. Before Installation 1. Ensure that available voltage and phase corresponds with Blower Pack voltage and phase as indicated on Blower Pack’s specification label. 2. Ensure that the dedicated external fuse disconnect is of sufficient size to handle the rated amps as indicated on the specification label. Refer to local codes. 3. Report any discrepancy immediately to the site engineer. 4. Ensure sufficient clearances will be available as described in the “Location and Mounting” section. 5. Ensure steam lines can be routed to blower pack as described in the “Steam Lines” section. Figure 1: Specification Label Location RM-BP and NH-EL Space Blower Pack Installation Guide | 2 Humidifier Components RM-BP (Remote Mounted Blower Pack) Figure 2: Humidifier Components RM-BP Table 1: Function of Components Component Function of Component Fan Intake Grill Protects the fan from foreign objects Controls the fan speed between High and Low. High speed will generate a louder Speed Switch fan noise but achieve best absorption performance. Diffuser Provides uniform distribution of steam from blower pack Steam Inlet Connects to humidifier steam outlet with steam hose Provides egress for condensed steam inside blower pack. Connects to drain or Condensate Outlet drain water cooler Electrical Cord Used to provide power (115v) to humidifier Low Voltage Connector Provides feedback to humidifier when power is provided to blower pack 3 | Blower Pack Installation Guide NH-EL Space Figure 3: Humidifier components NH-EL Space Table 2 : Function of Components Component Function of Component Fan Intake Grill Protects the fan from foreign objects Speed Switch Controls the fan speed between High and Low Diffuser Provides uniform distribution of steam from blower pack Blower Pack Installation Guide | 4 Models Blower packs are an optional accessory used to directly distribute steam to localized areas or in structures that do not have a built-on air distribution system. The Remote Mounted Blower Pack (RM-BP) model requires field piping to be completed on site. The NH-EL Space humidifier models come pre-assembled with a Blower Pack mounted on the top. Both smaller steam capacity NH-EL models (5-30 lbs/hr) and medium steam capacity NH-EL models (45-100 lbs/hr) can be ordered for direct In-Space steam distribution. Figure 4: Models for RM-BP and NH-EL Space For in-space distribution with large steam size humidifier capacities greater than 100lbs/hr, (Dual cylinder NH-EL 150, 200, GSTC, SETC) , the RM-BP (remote mounted blower pack) must be added to humidifier. See “Installation” section 5 | Blower Pack Installation Guide Installation Typical installation Figure 5: Typical Installation Blower Pack Installation Guide | 6 Location and Mounting: NH-EL Space Refer to NH-EL Installation and operation manual (2570435) for instructions on mounting the NH- EL. RM-BP To wall mount the RM-BP, use 2 #12 x 3” long wood screws, supplied by others. These screws must be fastened securely on a 2 x 4 wood stud or equivalent support. If any spacer material is used between the bracket and the structural material such as drywall, increase the fastener length accordingly. DO NOT locate the humidifier any further then absolutely necessary from the blower pack location as net output will be reduced as a result of heat loss through the steam line. Blower packs have hot surfaces that could result in burns if touched. Mount blower pack on a suitable wall or vertical surface. Clearance dimensions shown are for reference only and are the minimum required for maintenance of the humidifier. Consult local and national codes before final location and installation. NORTEC does not accept responsibility for installation code violations. Install only in areas with ambient temperature 41-104 °F (5 – 40 °C) relative humidity 5 - 95% (non condensing). When possible, mount the blower pack at a height convenient for servicing. Figure 6: NH-EL Space Mounting Clearances 7 | Blower Pack Installation Guide Note: Do not mount on hot surfaces, where freezing can occur, vibrating surface, or floor. Keyholes are spaced 12 in. (30.48 cm) apart center to center. Insert screws into the studs until there is 1/4 in. (0.64cm) of screw exposed. Be sure the screws are level to each other. Raise the unit and place the screws through the keyholes. Make sure the unit is level, then tighten the screws to secure the unit in place. Place L Shaped brackets on top of the unit, with holes inline with the studs. Using the appropriate sized wood screw, fasten the “L” brackets to the studs, securing the unit from any upward motion Note: Use screws longer than 3/4” (7.5 cm) if drywall or other spacer is present. Figure 7: RM-BP Mounting Detail Blower Pack Installation Guide | 8 Do NOT use blower packs as ducted blowers. The air volume from a blower pack is not sufficient for proper operation in a ducted system. Table 3: Clearances for Blower Packs on Low Speed* Minimum Min. Left side Min. Right Humidification Min. Frontal Min. Overhead No. of Clearance side Capacity Clearance Clearance Blower Inches (cm) Clearance lbs/hr (kg/hr) Inches (cm) Inches (cm) Packs Inches (cm) 5 (2.2) 1 9 (23) 12 (31) 12 (31) 12 (31) 10 (4.5) 1 18 (46) 12 (31) 12 (31) 12 (31) 20 (9.1) 1 75 (191) 12 (31) 12 (31) 12 (31) 30 (13.6) 1 86 (219) 12 (31) 12 (31) 12 (31) 50 (22.6) 1 174 (442) 12 (31) 12 (31) 12 (31) 75 (34.1) 1 189 (481) 48 (122) 30 (77) 30 (77) 100 (45.4) 1 248 (630) 84 (214) 30 (77) 30 (77) Sound measurement: 57.4 db Table 4: Clearances for blower Packs on High Speed* Minimum Min. Left side Min. Right Humidification Min. Frontal Min. Overhead No. of Clearance side Capacity Clearance Clearance Blower Inches (cm) Clearance lbs/hr (kg/hr) Inches (cm) Inches (cm) Packs Inches (cm) 5 (2.2) 1 6 (16) 12 (31) 12 (31) 12 (31) 10 (4.5) 1 6 (16) 12 (31) 12 (31) 12 (31) 20 (9.1) 1 60 (153) 12 (31) 12 (31) 12 (31) 30 (13.6) 1 71 (181) 12 (31) 12 (31) 12 (31) 50 (22.6) 1 132 (336) 12 (31) 12 (31) 12 (31) 75 (34.1) 1 153 (389) 12 (31) 30 (77) 30 (77) 100 (45.4) 1 218 (554) 12 (31) 30 (77) 30 (77) Sound measurement: 64.1 db *NOTES: Nominal Conditions 72˚F (21.1˚C), 40% RH.
Recommended publications
  • The Gold Standard in Fan Heaters
    WALL FAN HEATER ARWF SERIES THE GOLD STANDARD IN FAN HEATERS The PULSAIR™ is extremely popular for many reasons. First, it can be recessed or surface mounted with a surface adapter (optional). In addition, it can be mounted vertically or horizontally, directing the air flow upward or downward and to the right or to the left, respectively. Last, the slim-line PULSAIR™ can be recessed into W W W W Y Y Y A A A A T T a wall thickness of 2 in. to 3 in. While it’s a winning heating solu- T R R R R N N N R R R R A A A LIFETIME A A A A R R R N N N N R R R on element T T T T A A A tion for the hallway and bathroom, it can also be installed in other Y Y Y Y W W W W W W parts of the house, such as the office or in commercial buildings. W Y Y Y Y A A A A T T T T R R R R N N N R N Its nichrome element provides instant heat. Available from 500 W R A R A R A A A A R A R A R R N N N N 2YEAR R 3YEAR R 5YEAR R 5YEAR R T A T A T A T to 2000 W, and from 120 V to 277 V, the PULSAIR™ is recognized Y Y Y Y A W W W W W W W W and recommended by those in the know.
    [Show full text]
  • Single Pole Humidity Sensor and Fan Controller Cat
    Single Pole Humidity Sensor and Fan Controller Cat. Nos. IPHS5 - INDOOR USE ONLY 120VAC, 60Hz - Single Pole Only Incandescent: 600W - MLV/Fluorescent: 400VA - LED/CFL: 150W - Fan: 1/6Hp WARNINGS CAUTIONS • TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER • Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! liquids. • TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to • No user serviceable components. DO NOT attempt to service or repair. control a receptacle, or a load in excess of the specified rating. • Use this device WITH COPPER CLAD WIRE ONLY. • To be installed and/or used in accordance with electrical codes and regulations. • If you are not sure about any part of these instructions, consult an electrician. DI-000-IPHS5-02B INSTALLATION ENGLISH Features Location You Will Need: The humidity sensor and fan controller senses the humidity of your bathroom • Slotted/Phillips screwdriver • For bathroom applications the device should be placed and turns your bath fan or fan/light on when the humidity gets too high, • Pencil reducing condensation in your bathroom and increasing ventilation when used at a level to detect steam. Placing the detector directly in other household spaces. above a heater or near drafts is not recommended. • Electrical tape • Compatible with Incandescent, LED, CFL and Fluorescent loads when • NOTE: DO NOT use to control a fan/light combination • Cutters used with combination fan and light fixtures. where the fan/light is the only means of illumination.
    [Show full text]
  • Delta Fan Heater
    PAGE 1/2 DELTA FAN HEATER DELTA is a robust, reliable fan heater that is designed for use in TECHNICAL DATA areas that require a little more of materials and performance, for Voltage range: instance construction sites and ships. • 1x110V to 3x690V + PE DELTA is also used for more permanent installations such as in- Frequenzy, can be used at: dustrial buildings and warehouses, workshops, factories or ga- • 50 Hz and 60 Hz rages, as it can go from transportable to permanent fixture with Degree of protection for electrical components: a simple wall-bracket. • TP1: 3-9kW = IP44 • TP2: 15-21kW = IP34 It comes with an integrated 0-40°C room thermostat that en- Temperature control: sures optimal operation and minimizes energy consumption, as • TP1: Combi termostat with adjustable room thermostat 0-40°C well as a thermal cut-out to protect against overheating. The + thermal cut-out fan heater works without standby and does not use unneces- • TP2: Adjustable room thermostat 0-40°C + thermal cut-out sary power. Level regulation: • Manually operated 5-level change-over switch that regulates DELTA is built with internal casing in the heating chamber, which air speed and heating effect. Moreover, all types can be sup- ensures that the entire flow of air passes over the heating ele- plied with a 24-hour timer. A DELTA fan heater with timer ments. This eliminates problems with varying airflow and cold function switches on when the set time has elapsed. spots. Off The DELTA fan heater comes in two sizes: • TP1 = 3-9 kW - small cabinet Fan on • TP2 = 15-21 kW - large cabinet Half fan and half heat effect TP1: 372 mm TP1: 300 mm TP2: 462 mm TP2: 360 mm Full fan and half heat effect Full fan and full heat effect TP1: 435 mm TP2: 540 mm TP1: 322 mm ELECTRICAL INSTALLATION TP2: 392 mm Permanent installation must always be performed by an authori- zed electrician in accordance with relevant laws and regulations.
    [Show full text]
  • Airflow Measuring System Using Piezometer Ring – IM-105
    IM-105 Piezometer Ring June 2021 Installation, Operation & Maintenance Manual REVIEW AMCA BULLETIN 410 PRIOR TO INSTALLATION This manual has been prepared to guide the users of an airflow measuring system using a piezometer ring in the proper installation, operation and maintenance procedures to ensure maximum equipment life with trouble-free operation. For safe installation, startup and operational life of this equipment, it is important that all involved with the equipment be well versed in proper fan safety practices and read this manual. It is the user’s responsibility to make sure that all requirements of good safety practices and any applicable safety codes are strictly adhered to. Because of the wide variety of equipment covered in this manual, the instructions given here are general in nature. Additional product and engineering information is available at www.tcf.com. SAFETY NOTICE Refer to the safety section(s) in this manual prior to installing or servicing the fan. The most current version of this installation and maintenance manual can be found on our website at www.tcf.com/resources/im-manuals. Table of Contents Safety & Hazard Warnings ...........................................................................................................................................................................2 Shipping & Receiving ....................................................................................................................................................................................2 Handling ......................................................................................................................................................................................................
    [Show full text]
  • Optimization of Heat Exchanger Design and Fan Selection for Single Stage Refrigeration/Heat Pump Systems T
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 1986 Optimization of Heat Exchanger Design and Fan Selection for Single Stage Refrigeration/Heat Pump Systems T. H. Kuehn Follow this and additional works at: http://docs.lib.purdue.edu/iracc Kuehn, T. H., "Optimization of Heat Exchanger Design and Fan Selection for Single Stage Refrigeration/Heat Pump Systems" (1986). International Refrigeration and Air Conditioning Conference. Paper 24. http://docs.lib.purdue.edu/iracc/24 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html OPTIMIZATION OF HEAT EXCHANGER DESIGN AND FAN SELECTION FOR SINGLE STAGE REFRIGERATION/HEAT PUMP SYSTEMS THOMAS H. KUEHN Thermal Environmental Engineering Division, Department of Mechanical Engineering. University of Minnesota, Minneapolis, Minnesota, U.S.A. 1. INTRODUCTION Thermodynamic second law analysis can be employed to determine where losses occur in a given system. Inputs to this analysis include thermodynamic state information, mass flows, work transfers and heat exchange. Applications to vapor compression refrigeration and heat pump systems are outlined in references /1/ and /2/. However additional details of the processes are required to identify the nature of the losses. From this detailed information one can then begin to develop simple models useful in component or system thermodynamic optimization. A thermodynamic second law analysis is performed on an air cooled single stage mechanical vapor compression refrigeration system operating steadily under full load.
    [Show full text]
  • Cooling Your Home with Fans and Ventilation
    DOE/GO-102001-1278 FS228 June 2001 Cooling Your Home with Fans and Ventilation You can save energy and money when Principles of Cooling you ventilate your home instead of using your air conditioner, except on the hottest Cooling the Human Body days. Moving air can remove heat from Your body can cool down through three your home. Moving air also creates a wind processes: convection, radiation, and per- chill effect that cools your body. spiration. Ventilation enhances all these processes. Ventilation cooling is usually combined with energy conservation measures like Convection occurs when heat is carried shading provided by trees and window away from your body via moving air. If the treatments, roof reflectivity (light-colored surrounding air is cooler than your skin, roof), and attic insulation. Mechanical air the air will absorb your heat and rise. As circulation can be used with natural venti- the warmed air rises around you, cooler air lation to increase comfort, or with air con- moves in to take its place and absorb more ditioning for energy savings. of your warmth. The faster this convecting air moves, the cooler you feel. Ventilation provides other benefits besides cooling. Indoor air pollutants tend to accu- Radiation occurs when heat radiates mulate in homes with poor ventilation, and across the space between you and the when homes are closed up for air condi- objects in your home. If objects are tioning or heating. warmer than you are, heat will travel toward you. Removing heat through ventila- tion reduces the tem- perature of the ceiling, walls, and furnishings.
    [Show full text]
  • HMIC Series Fan and Bypass Humidifiers
    HMIC Series Fan and Bypass Humidifiers Model: HMICSB12B Model: HMICLF18B Model: HMICLB17B As warm air passes through the humidifier pad and water flows through it, natural evaporation takes place. This creates comforting humidity which is distributed throughout the house by your forced air heating system. OPTIMAL GENERATION OF COMFORTING THREE HUMIDITY CONTROL OPTIONS. MOISTURE. Choose between 3 separate control options; the Working together, water solenoid valve, water humidistat, the HumidiTrac and the Thermidistat metering orifice, water distribution tray and aluminum control. Each option provides precise control of humidifier pad efficiently generate maximum levels of humidity levels in your home. comforting moisture. QUIET OPERATION. SIMPLE, INFREQUENT MAINTENANCE. Nearly silent operation is the result of ICP Designed for easy serviceability. In most instances, it Branded Humidifier’s precision engineered fan takes less than 1/2 hour since maintenance (including and motor combination in the large fan powered changing the humidifier pad) is performed once a unit. In all units, air is quietly drawn through the season. Unlike portables, there are no reservoirs humidifier pad which efficiently turns water into which need to be frequently cleaned and refilled. water vapor to humidify your home. LONG LASTING HIGH QUALITY COMPONENTS. WARRANTY. With proper maintenance, your humidifier will last for Electrical components are covered by a five-year many years. That’s because it’s designed with durable limited warranty and the entire unit is backed by UV and corrosion resistant plastic. This plastic resists a one-year limited warranty. deterioration even when exposed to Ultraviolet light sources common in many systems today. HMIC Series Humidifiers include a packet with logos for the ICP brands.
    [Show full text]
  • Analysis of Heat Transfer in Air Cooled Condensers
    Analysis of Heat Transfer in Air Cooled Condensers Sigríður Bára Ingadóttir FacultyFaculty of of Industrial Industrial Engineering, Engineering, Mechanical Mechanical Engineering Engineering and and ComputerComputer Science Science UniversityUniversity of of Iceland Iceland 20142014 ANALYSIS OF HEAT TRANSFER IN AIR COOLED CONDENSERS Sigríður Bára Ingadóttir 30 ECTS thesis submitted in partial fulfillment of a Magister Scientiarum degree in Mechanical Engineering Advisors Halldór Pálsson, Associate Professor, University of Iceland Óttar Kjartansson, Green Energy Group AS Gestur Bárðarson, Green Energy Group AS Faculty Representative Ármann Gylfason, Associate Professor, Reykjavík University Faculty of Industrial Engineering, Mechanical Engineering and Computer Science School of Engineering and Natural Sciences University of Iceland Reykjavik, May 2014 Analysis of Heat Transfer in Air Cooled Condensers Analysis of Heat Transfer in ACCs 30 ECTS thesis submitted in partial fulfillment of a M.Sc. degree in Mechanical Engi- neering Copyright c 2014 Sigríður Bára Ingadóttir All rights reserved Faculty of Industrial Engineering, Mechanical Engineering and Computer Science School of Engineering and Natural Sciences University of Iceland VRII, Hjardarhagi 2-6 107, Reykjavik, Reykjavik Iceland Telephone: 525 4000 Bibliographic information: Sigríður Bára Ingadóttir, 2014, Analysis of Heat Transfer in Air Cooled Condensers, M.Sc. thesis, Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, University of Iceland. Printing: Háskólaprent, Fálkagata 2, 107 Reykjavík Reykjavik, Iceland, May 2014 Abstract Condensing units at geothermal power plants containing surface condensers and cooling towers utilize great amounts of water. Air cooled condensers (ACCs) are not typically paired with dry or flash steam geothermal power plants, but can be a viable solution to eliminate the extensive water usage and vapor emissions related to water cooled systems.
    [Show full text]
  • Effects of Varying Fan Speed on a Refrigerator/Freezer System
    University of Illinois at Urbana-Champaign Air Conditioning and Refrigeration Center A National Science Foundation/University Cooperative Research Center Effects of Varying Fan Speed on a Refrigerator/Freezer System A. R. Cavallaro and C. W. Bullard ACRC TR-63 July 1994 For additional information: Air Conditioning and Refrigeration Center University of Illinois Mechanical & Industrial Engineering Dept. 1206 West Green Street Urbana, IL 61801 Prepared as part of ACRC Project 30 Cycling Performance of Refrigerator-Freezers (217) 333-3115 C. W. Bullard, Principal Investigator The Air Conditioning and Refrigeration Center was founded in 1988 with a grant from the estate of Richard W. Kritzer, the founder of Peerless of America Inc. A State of Illinois Technology Challenge Grant helped build the laboratory facilities. The ACRC receives continuing support from the Richard W. Kritzer Endowment and the National Science Foundation. The following organizations have also become sponsors of the Center. Acustar Division of Chrysler Allied Signal, Inc. Amana Refrigeration, Inc. Brazeway, Inc. Carrier Corporation Caterpillar, Inc. E. I. duPont Nemours & Co. Electric Power Research Institute Ford Motor Company Frigidaire Company General Electric Company Harrison Division of GM ICI Americas, Inc. Modine Manufacturing Company Peerless of America, Inc. Environmental Protection Agency U.S. Army CERL Whirlpool Corporation For additional information: Air Conditioning & Refrigeration Center Mechanical & Industrial Engineering Dept. University of Illinois 1206 West Green Street Urbana, IL 61801 217 333 3115 Abstract Air-side heat transfer correlations were developed to describe variable conductance models for the condenser and evaporator. Few experimentally estimated parameters described well the changes of refrigerant and air-side conditions over a wide range of steady-state operating conditions for the extensively instrumented test refrigerator.
    [Show full text]
  • Ultra-Aire 150H Whole House Ventilating Dehumidifier UA-150H • Part No
    INSTALLER’S & OWNER’S MANUAL Ultra-Aire 150H Whole House Ventilating Dehumidifier UA-150H • Part No. 4024371 • Serial No.________________________________ Dehumidification Fresh Air Ventilation The highly efficient Ultra-Aire 150H dehumidifier utilizes refrigeration Optional fresh outdoor air may be ducted to the unit via a six inch to cool the incoming air stream below its dew point. This cooled and round duct. This provides fresh air to dilute pollutants and maintain drier air is used to pre-cool the incoming air stream resulting in a high oxygen content in the air. The amount of fresh air ventilation can significant increase in overall efficiency. After the pre-cooling stage, be regulated by a variety of dampers and controls. the processed air is reheated by passing through the condenser coil. The heat removed by the evaporator coil is returned to the air stream, Air Filtration resulting in an overall temperature increase of the air leaving the unit. The UA-150H includes air filtration to improve indoor air quality. A MERV-11 media filter is standard. An optional MERV-14 deep pleated The Ultra-Aire 150H is controlled by 24 volt remote wired controls. A 95% media filter is available for optimum air filtration and to reduce variety of controls are available suitable to various applications. potentially harmful airborne particles. If the optional filter is chosen, the standard filter operates as a prefilter. HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER © 2006 Therma-Stor LLC Manual P/N TS-245h 6/07 TABLE OF CONTENTS Table of Contents Safety Precautions .......................................................................3 5.3H Damper Operation and Setting ...............................13 1.
    [Show full text]
  • The Use of Portable Fans and Portable Air Conditioning Units During COVID-19 in Long-Term Care and Retirement Homes
    AT A GLANCE The Use of Portable Fans and Portable Air Conditioning Units during COVID-19 in Long- term Care and Retirement Homes Key Findings Careful consideration should be given to the use of portable fans and air conditioning units in long-term care homes or retirement homes. Portable fans and portable air conditioning units require routine cleaning and preventative maintenance. Portable fans and portable air conditioning units need to be strategically located to minimize risk of potential healthcare-associated infections. Alternative cooling methods should be explored in the long-term care setting. Introduction Seasonal hot weather including extreme heat events (EHE) can impact our health and well-being, including those residing in long-term care homes (LTCH) and retirement homes (RH) where central air conditioning is unavailable. Several long-term care and retirement homes have old building design with no centralized heating, ventilation, and air conditioning (HVAC) system. Long-term care and retirement homes need to use alternative methods such as portable fans or portable air conditioning (AC) units to improve residents’ comfort and reduce the illnesses associated with excessive heat. Health care facilities such as LTCH need to be aware of the potential risk of infection transmission associated with some of the heat relief options. This document provides recommendations for consideration on the use of portable fans and air conditioning units in these facilities. Background The risk of heat-related illnesses is higher in elderly
    [Show full text]
  • Improving Ventilation and Indoor Air Quality During Wildfire Smoke Events Recommendations for Schools and Buildings with Mechanical Ventilation
    Improving Ventilation and Indoor Air Quality during Wildfire Smoke Events Recommendations for Schools and Buildings with Mechanical Ventilation Overview • Smoke is a complex mixture of carbon dioxide (CO2), water vapor, carbon monoxide (CO), hydrocarbons, other organic chemicals, nitrogen oxides (NOX), trace minerals, and particulate matter. o Particulate matter consists of solid particles and liquid droplets suspended in the air. Particles with diameters less than 10 microns (PM10) are upper respiratory tract and eye irritants. o Smaller particles (PM2.5) are the greatest health concern – they can be inhaled deep into the lungs, and can affect respiratory and heart health. o Carbon monoxide, a colorless, odorless gas produced by incomplete combustion, is a particular health concern and levels are highest during the smoldering stages of a fire. • Outdoor (ambient) air pollutants, including smoke, enter and leave buildings in three primary ways: 1. Mechanical ventilation systems, which actively draw in outdoor air through intake vents and distribute it throughout the building. 2. Natural ventilation (opening of doors or windows). 3. Infiltration, the passive entry of unfiltered outdoor air through small cracks and gaps in the building shell. • Tightly closed buildings reduce exposure to outdoor air pollution. Upgrading the filter efficiency of the heating, ventilating, and air-conditioning (HVAC) system and changing filters frequently during smoke events greatly improves indoor air quality. Supplementing with HEPA filters, particularly those with activated charcoal or other adsorbents, improves air quality even more. • During long-term smoke events, take advantage of periods of improved air quality (such as during rain or shifts in wind) to use natural ventilation to flush-out the building.
    [Show full text]