Schedule 3 Design and Construction Specifications
Total Page:16
File Type:pdf, Size:1020Kb
SCHEDULE 3 DESIGN AND CONSTRUCTION SPECIFICATIONS 2071280.19 Schedule 3 – Design and Construction Specifications (Surrey Memorial Hospital Project) EXECUTION COPY TABLE OF CONTENTS PART 1. INTERPRETATION................................................................................................................. 1 1.1 Definitions.................................................................................................................................. 1 1.2 Interpretation.............................................................................................................................. 2 1.3 Acronym List.............................................................................................................................. 2 PART 2. GENERAL............................................................................................................................... 6 2.1 Standards .................................................................................................................................. 6 2.2 Use of Wood............................................................................................................................ 12 2.3 Clinical Specifications.............................................................................................................. 12 2.4 Additional Rooms and Spaces ................................................................................................ 12 2.5 Future Conversion of Non-Clinical Space ............................................................................... 12 2.6 Helipad..................................................................................................................................... 12 2.7 UBC Videoconference Rooms................................................................................................. 13 2.8 Indicative Design ..................................................................................................................... 13 2.9 Commercial Opportunities ....................................................................................................... 13 PART 3. DESIGN PRINCIPLES AND OBJECTIVES ......................................................................... 13 3.1 Evidence Based Design .......................................................................................................... 13 3.2 Project Design Objectives .......................................................................................................14 3.3 Master Planning....................................................................................................................... 14 3.4 Sustainability............................................................................................................................ 15 3.5 Optimized Outcomes ............................................................................................................... 16 3.6 Adaptability, Flexibility and Expansion .................................................................................... 16 3.7 Environmental Quality ............................................................................................................. 17 PART 4. SITE DEVELOPMENT REQUIREMENTS............................................................................ 18 4.1 Master Planning....................................................................................................................... 18 4.2 Urban Design and Site Development ...................................................................................... 18 4.3 Connections to Existing Hospital and Site Services................................................................ 24 4.4 Site Infrastructure .................................................................................................................... 26 PART 5. BUILDING DESIGN REQUIREMENTS ................................................................................ 28 5.1 Adaptability and Flexibility ....................................................................................................... 28 5.2 Expandability ........................................................................................................................... 29 5.3 Post Disaster Requirements.................................................................................................... 29 5.4 Architecture.............................................................................................................................. 31 5.5 Interior Environment ................................................................................................................ 36 5.6 Structural Design ..................................................................................................................... 43 PART 6. FACILITIES CONSTRUCTION SUBGROUP SPECIFICATIONS ....................................... 51 6.1 Procurement and Contracting Requirements (Division 1) – NOT USED ................................ 51 6.2 Existing Conditions (Division 2)............................................................................................... 51 6.3 Concrete (Division 3) ............................................................................................................... 51 2071280.19 Schedule 3 – Design and Construction Specifications (Surrey Memorial Hospital Project) EXECUTION COPY ii 6.4 Masonry (Division 4)................................................................................................................ 52 6.5 Metals (Division 5) ................................................................................................................... 53 6.6 Wood Plastics and Composites (including Millwork) (Division 6)............................................ 55 6.7 Thermal and Moisture Protection (Division 7) ......................................................................... 57 6.8 Openings (Division 8) .............................................................................................................. 62 6.9 Finishes (Division 9) ................................................................................................................ 72 6.10 Specialties (Division 10) .......................................................................................................... 83 6.11 Equipment (Division 11) .......................................................................................................... 88 6.12 Furnishings (Division 12) ......................................................................................................... 88 6.13 Special Construction (Division 13) .......................................................................................... 95 6.14 Conveying Equipment (Division 14) ........................................................................................ 98 6.15 General Administration and Support Offices - Demountable Partitions and Sound Masking103 PART 7. FACILITIES SERVICES SUBGROUP SPECIFICATIONS ................................................ 113 7.1 Mechanical Systems Design Principles................................................................................. 113 7.2 Fire Suppression (Division 21) .............................................................................................. 115 7.3 Plumbing (Division 22)........................................................................................................... 116 7.4 Heating, Ventilating and Air Conditioning (Division 23)......................................................... 126 7.5 Reserved for Future Expansion (Division 24) – NOT USED................................................. 137 7.6 Integrated Automation (Division 25) ...................................................................................... 137 7.7 Electrical (Division 26) ........................................................................................................... 139 7.8 Communications (Division 27)............................................................................................... 166 7.9 Electronic Safety and Security (Division 28) ......................................................................... 200 PART 8. SITE AND INFRASTRUCTURE SUBGROUP SPECIFICATIONS .................................... 213 8.1 Exterior Improvements (Division 32) ..................................................................................... 213 8.2 Utilities (Division 33) – Not used............................................................................................ 215 2071280.19 Schedule 3 – Design and Construction Specifications (Surrey Memorial Hospital Project) EXECUTION COPY ii APPENDIX 3A CLINICAL SPECIFICATION APPENDIX 3B UBC VIDEOCONFERENCE ROOM SPECIFICATIONS APPENDIX 3C MEDICAL GAS REQUIREMENTS APPENDIX 3D SOUND TRANSMISSION RATINGS APPENDIX 3E CABLE INFRASTRUCTURE STANDARD APPENDIX 3F WIRELESS INFRASTRUCTURE STANDARD APPENDIX 3G WIRELESS DATA COMMUNICATIONS POLICY APPENDIX 3H A/V AND VIDEO CONFERENCING STANDARD APPENDIX 3I IM/IT PREFERRED VENDORS APPENDIX 3J CHARLES BARHAM BUILDING 2071280.19 Schedule 3 – Design and Construction Specifications (Surrey Memorial Hospital Project) EXECUTION COPY SCHEDULE 3 DESIGN AND CONSTRUCTION SPECIFICATIONS PART 1. INTERPRETATION 1.1 Definitions In this Schedule, in addition to the definitions set out in Schedule 1 of this Agreement: “BC Building Code” means the British Columbia Building Code; “BMS” has the meaning set out in Section 7.6.1.1(1)