Symmetry Surgical® Sterilization Solutions Portfolio

Total Page:16

File Type:pdf, Size:1020Kb

Symmetry Surgical® Sterilization Solutions Portfolio Sterilization Scan the code above to learn more about our Sterilization Solutions portfolio. Solutions Portfolio Sterilization Solutions FlashPak® SS-2 Quad-Lock® Sterilization Container SS-4 Ultra™ Container System SS-10 DentalPak SS-17 EndoPak SS-18 MicroPak SS-19 MultiPak SS-21 Quick Kit SS-31 ScopePak SS-33 StackPak SS-35 TransPak SS-36 Specialty Trays SS-37 Sterilization Accessories SS-45 Questions? Contact us at [email protected] or learn more at symmetrysurgical.com The Surgical Instrument Desk Reference How to Use Our Catalog U.S. Customer Service The Symmetry Surgical catalog is designed with Your Symmetry Surgical Customer Service team wants you in mind, to be your trusted resource for surgical to make ordering surgical instruments the easiest part instrumentation. We took great care in creating an of your day. We accept orders via phone, fax, email, our easy-to-use, robust catalog and we think you'll be website, Global Healthcare Exchange (GHX) and pleased with the design as you become more familiar through the mail. with our broad portfolio. PHONE 1.800.251.3000 Layout (Available Monday through Friday, 8:30 AM–6:30 PM EST) The catalog is organized by surgical specialty and FAX product function. 1.800.342.3272 And we know that it is difficult to pick up an instrument EMAIL and know what specialty it's listed in. To make your job [email protected] easier, we've sorted the instruments in our portfolio by surgical function, too, including Energy, Laparoscopic, ONLINE Retractors and Sterilization Solutions. symmetrysurgical.com MAILING ADDRESS Symmetry Surgical Attn: Customer Service 3034 Owen Drive Antioch, TN 37013 Please consult the product Instructions for Use, inserts and labels for specific information regarding intended use, contra-indications, warnings and cautions. Questions? Contact us at [email protected] or learn more at symmetrysurgical.com The Surgical Instrument Desk Reference International Customer Cardiovascular/Thoracic Service Energy PHONE Symmetry Surgical Switzerland GmbH Ear, Nose & Throat +41 (0) 52 557 59 00 (Available Monday through Friday, 7:00-16:00 GMT) General Symmetry Surgical, Inc., USA STERILIZATION 1.615.964.5672 (Available Monday through Friday, 8:30 AM–6:30 PM EST) Laparoscopic FAX Neurology Symmetry Surgical Switzerland GmbH +41 (0) 52 557 59 99 Obesity EMAIL [email protected] [email protected] OB/GYN ONLINE Ophthalmology symmetrysurgical.com MAILING ADDRESS Orthopedics & Arthroscopy Symmetry Surgical Switzerland GmbH Bühlstrasse 27 Pediatrics CH-8200 Schaffhausen Switzerland Rectal Symmetry Surgical, Inc. 3034 Owen Drive Antioch, TN 37013 Retractors INTERNATIONAL PAYMENT TERMS/RETURN Spine GOODS POLICY/INSTRUMENT REPAIR & RESTORE PROGRAM/LITERATURE REQUESTS Please contact your local distributor. Locate a local Urology distributor contact, International Customer Service at +41 (0) 52 557 59 00 or 1.615.964.5672 (US). Sterilization Solutions Alphabetical & Numeric Indexes Please consult the product Instructions for Use, inserts and labels for specific information regarding intended use, contra-indications, warnings and cautions. Questions? Contact us at [email protected] or learn more at symmetrysurgical.com SS-2 STERILIZATION SOLUTIONS FlashPak® FlashPak® The FlashPak® is a hospital-proven, closed-container system engineered for safe transport of immediate- use steam sterilized (flashed) instruments in a mobile, sterile field. Advanced plastic polymer construction provides long term durability. KEY BENEFITS: • Validated and FDA cleared for use in both gravity and pre-vacuum cycles • Accepts standard wire basket and a wide variety of trays to accommodate many types of instruments • Transparent lid for quick identification • Constructed of high-performance engineering polymers FlashPak® Units (Includes Base, Lid & Basket) CODE SIZE DIMENSIONS (INTERNAL) DIMENSIONS (EXTERNAL) 9020 Small 9 x 9 x 2 in 229 x 229 x 51 mm 11.5 x 11.2 x 7.3 in 292 x 284 x 185 mm 9030 Medium 9 x 18 x 3 in 229 x 457 x 76 mm 11.2 x 20.7 x 8.4 in 284 x 525 x 213 mm 9040 Large 9 x 22 x 3 in 229 x 559 x 76 mm 11 x 24.7 x 9 in 279 x 627 x 229 mm 9050 X-Large 10.5 x 21.25 x 3.5 in 266 x 539 x 89 mm 13 x 24.7 x 9 in 330 x 627 x 229 mm Base Only Lid with Seal CODE DESCRIPTION CODE DESCRIPTION 9020-01 For Part 9020 9020-02 For Part 9020 9030-01 For Part 9030 9030-02 For Part 9030 9040-01 For Part 9040 9040-02 For Part 9040 9050-01 For Part 9050 9050-02 For Part 9050 Please consult the product Instructions for Use, inserts and labels for specific information regarding intended use, contra-indications, warnings and cautions. Questions? Contact us at [email protected] or learn more at symmetrysurgical.com STERILIZATION SOLUTIONS SS-3 FlashPak® 9050 9030-04 Wire Basket Silicone Pin Mat STERILIZATION CODE DESCRIPTION CODE DESCRIPTION 9020-08 For Part Number 9020 9020-04 For Part Number 9020-08 9030-08 For Part Number 9030 9030-04 For Part Number 9030-08 9040-08 For Part Number 9040 9040-04 For Part Number 9040-08 9050-08 For Part Number 9050 9050-04 For Part Number 9050-08 9111 9030-13 9000-14 Base Assembly Includes Base, Pressure Balance Element and Gasket Accessories & Replacement Parts CODE DESCRIPTION CODE DESCRIPTION 9020-13 For Part Number 9020 9000-14 Autoclave Gloves (One Pair) 9030-13 For Part Number 9030 9020-11 Pressure Balance Element, for All Bases 9040-13 For Part Number 9040 9020-12 Balance Element Gasket, for All Bases 9050-13 For Part Number 9050 9111 FlashPak® Delivery Cart, for All Sizes Note: Does not include valve Evolution Valve CODE DESCRIPTION 9090 Evolution Valve Change Kit, Includes Two Valves and Hardware Adapter Kit 9090-90 Evolution Valve Kit 9090-92 Eight Mounting Nuts 9090-93 Four Mounting Bolts Please consult the product Instructions for Use, inserts and labels for specific information regarding intended use, contra-indications, warnings and cautions. Questions? Contact us at [email protected] or learn more at symmetrysurgical.com SS-4 STERILIZATION SOLUTIONS Quad-Lock® Sterilization Container How to Choose the Right Quad-Lock® Container 1. Locate the instruments that will go inside the container and determine, based on the number, size and weight of instruments, what size basket is needed to hold these instruments. NOTE: No instruments should sit above the inner edge of the basket. 2. Determine whether a Solid Bottom Container Base or Filter Bottom Container Base is appropriate based on the sterilization systems in use at your facility. NOTE: To determine the height of the container base, add the height of the basket, plus 1 inch (25 mm) for the Wire Base (if used), plus 2 inches (50 mm) of clearance. A wire base must be used with a Filter Bottom Container Base. Filter Bottom Container Base Example: 2 inch (50 mm) Basket + 1 inch (25 mm) Wire Base + 2 inches (50 mm) clearance = 5 inches (127 mm). 7. Consider Ergonomic Hand Grips in the color you Solid Bottom Container Base Example: prefer for each instrument set. Ergonomic Hand 2 inch (50 mm) Basket + 2 inches Grips are available in Gray, Yellow, Green, Blue, Red (50 mm) clearance = 4 inches (101 mm). and Black. 3. Select a Wire Base the same length as the basket 8. Consider Aluminum Nameplates in the color when using a Filter Base. you prefer for each instrument set. Aluminum Nameplates are available in Gray, Yellow, Green, 4. Consider a Protective Mat the same length as Blue, Red and Black. Make note of what should be your basket, or upgrade to Accessory Instrument etched on each Aluminum Nameplate, up to a Organizers appropriate for your specific 45 character limit. instrument set. Don’t Forget: 5. Add a Filter Lid in the color you prefer for each instrument set. Filter Lids are available in Gray, • Quad-Lock® Single-Use Filters Yellow, Green, Blue, Red and Black. • Quad-Lock® Single-Use Paper Label with Indicator ® 6. Consider a Security Lid in the color you prefer for • Quad-Lock Single-Use Security Seals each instrument set. Security Lids are available in Gray, Yellow, Green, Blue, Red and Black. See Product Information For Use for further details. Please consult the product Instructions for Use, inserts and labels for specific information regarding intended use, contra-indications, warnings and cautions. Questions? Contact us at [email protected] or learn more at symmetrysurgical.com STERILIZATION SOLUTIONS SS-5 Quad-Lock® Sterilization Container Filter Bottom Container Base CODE DESCRIPTION HEIGHT 50-8731 Half Length 4 in 101 mm 50-8732 Half Length 5 in 127 mm 50-8733 Half Length 6 in 152 mm 50-8734 Half Length 8 in 203 mm 50-8735 Half Length 10 in 260 mm STERILIZATION 50-8736 Three-Quarter Length 4 in 101 mm 50-8737 Three-Quarter Length 5 in 127 mm 50-8738 Three-Quarter Length 6 in 152 mm 50-8726 Full Length 4 in 101 mm 50-8727 Full Length 5 in 127 mm 50-8728 Full Length 6 in 152 mm 50-8729 Full Length 8 in 203 mm 50-8730 Full Length 10 in 260 mm 50-9044 Replacement Filter Rentention Disc, qty 1 Container Base Benefits • Number of heights available to fit even your largest instrument set Solid Bottom Container Base • The oversized ergonomic handles have a 90° CODE DESCRIPTION HEIGHT stop to protect fingers during transportation 50-8744 Half Length 4 in 101 mm • The container base has specially-designed feet 50-8745 Half Length 5 in 127 mm for secure stacking and standard slots for large 50-8746 Half Length 6 in 152 mm or small indicator cards or aluminum
Recommended publications
  • Landmarks in the History of Neurosurgery
    PART 1 General Overview 1 Landmarks in the History of Neurosurgery JAMES TAIT GOODRICH “If a physician makes a wound and cures a freeman, he shall receive ten running complex 21st-century stereotaxic frameless guided pieces of silver, but only five if the patient is the son of a plebeian or two systems. if he is a slave. However it is decreed that if a physician treats a patient In many museum and academic collections around the with a metal knife for a severe wound and has caused the man to die—his world are examples of the earliest form of neurosurgery—skull hands shall be cut off.” trephination.1–4 A number of arguments and interpretations —Code of Hammurabi (1792–50 BC) have been advanced by scholars as to the origin and surgical reasons for this early operation—to date no satisfactory answers have been found. Issues of religion, treatment of head injuries, release of demons, and treatment of headaches have all been offered. Unfortunately, no adequate archaeological materials n the history of neurosurgery there have occurred a number have surfaced to provide us with an answer. In reviewing some of events and landmarks, and these will be the focus of this of the early skulls, the skills of these early surgeons were quite chapter. In understanding the history of our profession, remarkable. Many of the trephined skulls show evidence of Iperhaps the neurosurgeon will be able explore more carefully healing, proving that these early patients survived the surgery. the subsequent chapters in this volume to avoid having his or Fig.
    [Show full text]
  • 434 Part 882—Neurological Devices
    Pt. 882 21 CFR Ch. I (4–1–12 Edition) PART 882—NEUROLOGICAL 882.1950 Tremor transducer. DEVICES Subparts C–D [Reserved] Subpart A—General Provisions Subpart E—Neurological Surgical Devices Sec. 882.4030 Skull plate anvil. 882.1 Scope. 882.4060 Ventricular cannula. 882.3 Effective dates of requirement for pre- 882.4100 Ventricular catheter. market approval. 882.4125 Neurosurgical chair. 882.9 Limitations of exemptions from sec- 882.4150 Scalp clip. tion 510(k) of the Federal Food, Drug, 882.4175 Aneurysm clip applier. and Cosmetic Act (the act). 882.4190 Clip forming/cutting instrument. 882.4200 Clip removal instrument. Subpart B—Neurological Diagnostic 882.4215 Clip rack. Devices 882.4250 Cryogenic surgical device. 882.4275 Dowel cutting instrument. 882.1020 Rigidity analyzer. 882.4300 Manual cranial drills, burrs, 882.1030 Ataxiagraph. trephines, and their accessories. 882.1200 Two-point discriminator. 882.4305 Powered compound cranial drills, 882.1240 Echoencephalograph. burrs, trephines, and their accessories. 882.1275 Electroconductive media. 882.4310 Powered simple cranial drills, 882.1310 Cortical electrode. burrs, trephines, and their accessories. 882.1320 Cutaneous electrode. 882.4325 Cranial drill handpiece (brace). 882.1330 Depth electrode. 882.4360 Electric cranial drill motor. 882.1340 Nasopharyngeal electrode. 882.4370 Pneumatic cranial drill motor. 882.1350 Needle electrode. 882.4400 Radiofrequency lesion generator. 882.1400 Electroencephalograph. 882.4440 Neurosurgical headrests. 882.1410 Electroencephalograph electrode/ 882.4460 Neurosurgical head holder (skull lead tester. clamp). 882.1420 Electroencephalogram (EEG) signal 882.4500 Cranioplasty material forming in- spectrum analyzer. strument. 882.1430 Electroencephalograph test signal 882.4525 Microsurgical instrument. generator. 882.1460 Nystagmograph.
    [Show full text]
  • SURGICAL INSTRUMENT CATALOG Codman SURGICAL PRODUCTS CATALOG
    SURGICAL INSTRUMENT CATALOG Codman SURGICAL PRODUCTS CATALOG © Codman & Shurtleff, Inc. 2008 All Rights Reserved Printed in U.S.A. TERMS OF SALE A. ORDERING INFORMATION 3. Warranty Repair and Restore products are warranted to be free Purchase orders may be addressed to: from defects in workmanship and material with respect Johnson & Johnson Health Care Systems, Inc. to the Repair and Restore only, and not with respect to 425 Hoes Lane, P.O. Box 6800 the original instrument. Piscataway, NJ 08855-6800 Attn: Customer Service C. SPECIAL ORDERS or telephoned to Johnson & Johnson Health Care Systems, Inc. Service Department toll free number Products that have been discontinued by Codman, 1-800-255-2500. Orders may also be placed with your may be available through our Repair Department. local Codman sales representative. Codman’s Special Devices Department provides hospi- To insure accuracy in ordering, please include the tals and surgeons with surgical instrumentation cus- following information when placing your order: tomized to individual specifications. 1. Catalog Number Order forms for Special Devices can be obtained from 2. Quantity your sales representative or by directly contacting the 3. Product Description Special Order Department at 1-800-843-0039. 4. Your Customer Number* For pricing, delivery, and more information regarding 5. Complete Billing and Shipping Addresses special order products, please call the Special Order 6. Special Instructions (i.e.: etching, method Department at 1-800-843-0039. of shipment) *Your customer Number can be provided to you by Johnson & Johnson Health Care Systems, Inc. Customer Service Department. All orders are subject to acceptance by Codman & Shurtleff, Inc./Johnson & Johnson D.
    [Show full text]
  • Impact of Virtual Reality in Arterial Anatomy Detection and Surgical Planning in Patients with Unruptured Anterior Communicating Artery Aneurysms
    brain sciences Article Impact of Virtual Reality in Arterial Anatomy Detection and Surgical Planning in Patients with Unruptured Anterior Communicating Artery Aneurysms Samer Zawy Alsofy 1,2,* , Ioanna Sakellaropoulou 2, Makoto Nakamura 3, Christian Ewelt 2, Asem Salma 4, Marc Lewitz 2, Heinz Welzel Saravia 2, Hraq Mourad Sarkis 2, Thomas Fortmann 2 and Ralf Stroop 1 1 Department of Medicine, Faculty of Health, Witten/Herdecke University, 58448 Witten, Germany; [email protected] 2 Department of Neurosurgery, St. Barbara-Hospital, Academic Hospital of Westfälische Wilhelms-University Münster, 59073 Hamm, Germany; [email protected] (I.S.); [email protected] (C.E.); [email protected] (M.L.); [email protected] (H.W.S.); [email protected] (H.M.S.); [email protected] (T.F.) 3 Department of Neurosurgery, Academic Hospital Köln-Merheim, Witten/Herdecke University, 51109 Köln, Germany; [email protected] 4 Department of Neurosurgery, St. Rita’s Neuroscience Institute, Lima, OH 45801, USA; [email protected] * Correspondence: [email protected] Received: 1 November 2020; Accepted: 8 December 2020; Published: 10 December 2020 Abstract: Anterior-communicating artery (ACoA) aneurysms have diverse configurations and anatomical variations. The evaluation and operative treatment of these aneurysms necessitates a perfect surgical strategy based on review of three-dimensional (3D) angioarchitecture using several radiologic imaging methods. We analyzed the influence of 3D virtual reality (VR) reconstructions versus conventional computed tomography angiography (CTA) scans on the identification of vascular anatomy and on surgical planning in patients with unruptured ACoA aneurysms. Medical files were retrospectively analyzed regarding patient- and disease-related data. Preoperative CTA scans were retrospectively reconstructed to 3D-VR images and visualized via VR software to detect the characteristics of unruptured ACoA aneurysms.
    [Show full text]
  • 394 Part 882—Neurological Devices
    Pt. 882 21 CFR Ch. I (4–1–01 Edition) subpart E of part 807 of this chapter 882.1900 Evoked response auditory stimu- subject to the limitations in § 880.9. lator. 882.1925 Ultrasonic scanner calibration test [63 FR 59718, Nov. 5, 1998] block. 882.1950 Tremor transducer. PART 882—NEUROLOGICAL DEVICES Subparts C–D [Reserved] Subpart E—Neurological Surgical Devices Subpart A—General Provisions 882.4030 Skull plate anvil. Sec. 882.4060 Ventricular cannula. 882.1 Scope. 882.4100 Ventricular catheter. 882.3 Effective dates of requirement for pre- 882.4125 Neurosurgical chair. market approval. 882.4150 Scalp clip. 882.9 Limitations of exemptions from sec- 882.4175 Aneurysm clip applier. tion 510(k) of the Federal Food, Drug, 882.4190 Clip forming/cutting instrument. and Cosmetic Act (the act). 882.4200 Clip removal instrument. 882.4215 Clip rack. Subpart B—Neurological Diagnostic 882.4250 Cryogenic surgical device. Devices 882.4275 Dowel cutting instrument. 882.4300 Manual cranial drills, burrs, 882.1020 Rigidity analyzer. trephines, and their accessories. 882.1030 Ataxiagraph. 882.4305 Powered compound cranial drills, 882.1200 Two-point discriminator. burrs, trephines, and their accessories. 882.1240 Echoencephalograph. 882.4310 Powered simple cranial drills, 882.1275 Electroconductive media. burrs, trephines, and their accessories. 882.1310 Cortical electrode. 882.4325 Cranial drill handpiece (brace). 882.1320 Cutaneous electrode. 882.4360 Electric cranial drill motor. 882.1330 Depth electrode. 882.4370 Pneumatic cranial drill motor. 882.1340 Nasopharyngeal electrode. 882.4400 Radiofrequency lesion generator. 882.1350 Needle electrode. 882.4440 Neurosurgical headrests. 882.1400 Electroencephalograph. 882.4460 Neurosurgical head holder (skull 882.1410 Electroencephalograph electrode/ clamp).
    [Show full text]
  • Neurosurgical Head Holder (Skull Clamp)
    Food and Drug Administration, HHS § 882.4460 nervous tissue by the application of ex- (b) Classification. Class I (general con- treme cold to the selected site. trols). The device is exempt from the (b) Classification. Class II (perform- premarket notification procedures in ance standards). subpart E of part 807 of this chapter subject to the limitations in § 882.9. § 882.4275 Dowel cutting instrument. [44 FR 51730–51778, Sept. 4, 1979, as amended (a) Identification. A dowel cutting in- at 61 FR 1123, Jan. 16, 1996; 66 FR 38808, July strument is a device used to cut dowels 25, 2001] of bone for bone grafting. (b) Classification. Class II (perform- § 882.4360 Electric cranial drill motor. ance standards). (a) Identification. An electric cranial drill motor is an electrically operated § 882.4300 Manual cranial drills, burrs, power source used with removable ro- trephines, and their accessories tating surgical cutting tools or drill (a) Identification. Manual cranial bits on a patient’s skull. drills, burrs, trephines, and their acces- (b) Classification. Class II (perform- sories are bone cutting and drilling in- ance standards). struments that are used without a power source on a patient’s skull. § 882.4370 Pneumatic cranial drill motor. (b) Classification. Class II (perform- ance standards). (a) Identification. A pneumatic cranial drill motor is a pneumatically operated § 882.4305 Powered compound cranial power source used with removable ro- drills, burrs, trephines, and their tating surgical cutting tools or drill accessories. bits on a patient’s skull. (a) Identification. Powered compound (b) Classification. Class II (perform- cranial drills, burrs, trephines, and ance standards).
    [Show full text]
  • The Choice of the Best Surgical Approach Remains Critical Despite the Technological Revolution
    Revisión de Temas https://doi.org/10.36593/rev.chil.neurocir.v46i1.185 The choice of the best surgical approach remains critical despite the technological revolution La selección del mejor abordaje sigue siendo fundamental pese a la revolución tecnológica Allan J. Drapkin, MD, FACS(R)1 1 Department of Surgery (Neurosurgery), Jersey Shore University Medical Center Neptune. New Jersey, USA. Resumen Este trabajo describe brevemente la Neurocirugía a mediados del siglo XX, en cuanto a Instrumental disponible y a los elementos de apoyo diagnóstico entonces existentes. Luego evalúa el impacto progresivo que la neurocirugía ha experimentado durante este período como resultado de la revolución tecnológica, destacando el hecho de que a pesar de estas sucesivas innovaciones, la selección del mejor abordaje quirúrgico en cada caso individual, basado en la neuroanatomía relacionada ha retenido una gran importancia. Palabras clave: Tecnología, progreso, abordaje quirúrgico. Abstract Following a brief description of the state of Neurosurgery in the mid XX Century, regarding both the instrumentation as well as the means of diagnosis existent at that time, an evaluation is made of the progressive impact that Neurosurgery has experienced as a consequence of the technological revolution, stressing the fact that, despite of the successive innovations experienced during this period, the selection of the surgical approach in each particular case has retained a great importance. Key words: Technology, progress, surgical approach. The technological explosion which has evolved during the bordering the limits of the planned craniotomy and then each past fifty years has clearly changed dramatically our specialty. pair of these burr holes had to be interconnected by manu- These advances have emerged both based on the accumulat- ally pulled saw wires which were used to cut the skull along a ing knowledge in neuroanatomy21 and function as well as in line connecting those burr holes.
    [Show full text]
  • Customer Discovery 120+ Interviews
    Customer Discovery 120+ Interviews Summer 2020 CONFIDENTIAL Use of material without permission strictly prohibited. Table of Contents 1. Key Needs Part 1 2. Competitor Analysis 3. Hubly Analysis Click to go to 4. Purchasing Pathway each section Part 2 5. Marketing Strategy 6. Hubly Marketing 7. Appendix Customer Discovery Part 1 Overview Using “Three Why’s” we analyzed competitors and Hubly’s technology with key surgeon needs to create a value proposition Why buy anything? Why buy Hubly? Why buy now? Understanding the priorities and Using the six key needs and We ideated marketing leverage needs of surgeons helped inform background research we analyzed points that address unmet needs with us on ways to answer why they Hubly and its competitors on how current drills that would motivate buy new drills well they address surgeon needs surgeons to “buy now” Part 1 Overview | Key Needs | Competitors | Hubly Key Needs Key Needs Interviews We employed the following methodology to identify surgeon preferences and, ultimately, our key needs for drills Buying Process • How much of a say do surgeons have in buying drills? • How often are new drills bought? Hospital Physicians (62) Residents (15) Administrators (14) • How do surgeons get information on new Click to edit Master subtitle style drills? Current Drills • What drills have you used? • What qualities do you look for in drills? • What specific qualities do you look for in single use drills? Technological Features • What new technologies are needed? • Would you like plunge prevention and finer
    [Show full text]
  • 384 Part 882—Neurological Devices
    § 880.6990 21 CFR Ch. I (4±1±99 Edition) § 880.6990 Infusion stand. 882.1825 Rheoencephalograph. 882.1835 Physiological signal amplifier. (a) Identification. The infusion stand 882.1845 Physiological signal conditioner. is a stationary or movable stand in- 882.1855 Electroencephalogram (EEG) te- tended to hold infusion liquids, infu- lemetry system. sion accessories, and other medical de- 882.1870 Evoked response electrical stimu- vices. lator. (b) Classification. Class I (general con- 882.1880 Evoked response mechanical stimu- lator. trols). The device is exempt from the 882.1890 Evoked response photic stimulator. premarket notification procedures in 882.1900 Evoked response auditory stimu- subpart E of part 807 of this chapter lator. subject to the limitations in § 880.9. 882.1925 Ultrasonic scanner calibration test block. [63 FR 59718, Nov. 5, 1998] 882.1950 Tremor transducer. PART 882ÐNEUROLOGICAL Subparts C±D [Reserved] DEVICES Subpart EÐNeurological Surgical Devices Subpart AÐGeneral Provisions 882.4030 Skull plate anvil. 882.4060 Ventricular cannula. Sec. 882.4100 Ventricular catheter. 882.1 Scope. 882.4125 Neurosurgical chair. 882.3 Effective dates of requirement for pre- 882.4150 Scalp clip. market approval. 882.4175 Aneurysm clip applier. 882.9 Limitations of exemptions from sec- 882.4190 Clip forming/cutting instrument. tion 510(k) of the Federal Food, Drug, 882.4200 Clip removal instrument. and Cosmetic Act (the act). 882.4215 Clip rack. 882.4250 Cryogenic surgical device. Subpart BÐNeurological Diagnostic 882.4275 Dowel cutting instrument. Devices 882.4300 Manual cranial drills, burrs, trephines, and their accessories. 882.1020 Rigidity analyzer. 882.4305 Powered compound cranial drills, 882.1030 Ataxiagraph.
    [Show full text]
  • 2016-Complete-Catalog.Pdf
    ® MEDFIX INTERNATIONAL, LLC ® MEDFIX International, LLC Spine / Ortho / General Surgical Instrumentation Guide ® medfix International LLC / www.medfix.com / 866.321.6331 3 ® MEDFIX International, LLC Reducing cost without compromising quality. - Medfix Founder medfix® International LLC / www.medfix.com / 866.321.6331 5 ® MEDFIX International, LLC Medfix International, LLC has been delivering quality, low cost instrumentation around the world for many years. As a result of our success in fulfilling our mission of reducing cost without compromising quality, we have been able to partner with the biggest suppliers in the United States and Germany for the distribution of general surgical instrumentation. With over 14,000 items in stock and an expanding catalog with thousands of instruments, we can outfit anything from a single suture removal station to the largest multi-discipline operating room anywhere in the world, from simple forceps to procedure-specific instrumentation trays. We can cross-reference almost any surgical instrument in the world by company and part number. The vast majority of our orders are shipped within 3 business days. If you want to reduce costs, improve lead times, and remove guesswork from outfitting your surgical service, contact us and find out how easy it is to do business with a leader in the industry. QUALITY ASSURANCE Our instruments are manufactured from the highest quality German surgical stainless steel (ASTM F899), are treated to be corrosion resistant, and meet or exceed the most stringent of FDA and CE certifications. Our instruments have been tested with the Thermo Scientific™ Niton XL3t XRF analyzer and show no significant variation from industry standard for type 420 stainless steel.
    [Show full text]
  • Global Tender Enquiry Document
    TENDER ENQUIRY DOCUMENT FOR PURCHASE OF MEDICAL EQUIPMENT FOR INSTITUTIONS GETTING UPGRADED UNDER PMSSY PHASE III On behalf of GOVT. OF INDIA MINISTRY OF HEALTH & FAMILY WELFARE HITES/PCD/PMSSY-III/31/NRSG/18-19 Through HLL INFRA TECH SERVICES LIMITED (Subsidiary of HLL Lifecare Ltd., a Govt. of India Enterprise) B-14 A, Sector-62, Noida - 201 307 Phone: 0120-4071500; Fax: 0120-4071513 URL: www.hllhites.com Email: [email protected] HLL Infra Tech Services Limited INDEX Section Topic Page No. Section I – Notice inviting e-Tender (e-NIT) ------------------------------------------------------- 03 Section II – General Instructions to Tenderers (GIT) ----------------------------------------------- 05 Section III – Special Instructions to Tenderers (SIT) ------------------------------------------------ 26 Section IV – General Conditions of Contract (GCC) ------------------------------------------------ 27 Section V – Special Conditions of Contract (SCC) ------------------------------------------------- 42 Section VI – List of Requirements --------------------------------------------------------------------- 43 Section VII – Technical Specifications ----------------------------------------------------------------- 45 Section VIII – Quality Control Requirements -------------------------------------------------------- 77 Section IX – Qualification Criteria ---------------------------------------------------------------------- 78 Section X – Tender Form -------------------------------------------------------------------------------- 80 Section XI
    [Show full text]
  • CODMAN® Cranial Hand Drill and Cranial Drill Bits
    CODMAN® Cranial Hand Drill and Cranial Drill Bits Integra LifeSciences Production Corporation 11 Cabot Boulevard Mansfield, MA 02048 USA Integra LifeSciences Services (France) Immeuble Séquoïa 2 97 Allée Alexandre Borodine Parc Technologique de la Porte des Alpes 69800 Saint Priest – France 2797 LCN 183299-001 Rev K 04/19 1290688-1 © 2019 Integra LifeSciences Corporation. All rights reserved. CODMAN Cranial Hand Drill and Cranial Drill Bits 1 2 i ENGLISH IMPORTANT INFORMATION Please Read Before Use CODMAN® Cranial Hand Drill and Cranial Drill Bits CODMAN Cranial Hand Drill 5.8 mm Cranial Drill Bit 2.7 mm Cranial Drill Bit Indications The CODMAN® Cranial Hand Drill and Cranial Drill Bits are indicated when a craniotomy is required for placement of an intracranial pressure (ICP) monitoring device and/or cerebrospinal fluid drainage device. Contraindications This device is not designed, sold, or intended for any use except as indicated. Complications Bleeding may occur at the site of the drill hole, originating from the scalp, bone, dural, or cerebral areas. Due to the possibility of cerebral or extracerebral hemorrhage or any other complication of this procedure, drill hole placement is the sole responsibility of the attending neurosurgeon. PRECAUTIONS It is essential to maintain strict aseptic technique during craniotomy procedures. Description The following products are available separately: CODMAN Cranial Hand Drill 82-6607 5.8 mm Cranial Drill Bit 82-6608 2.7 mm Cranial Drill Bit 82-6609 Each of the drill bits is packaged with a drill guide and a hex wrench. 1 Instructions for Use 1. After prepping and draping the patient, perform the incision and retraction techniques required to expose the skull.
    [Show full text]