Rectorseal 66114 Catalog.Pdf

Total Page:16

File Type:pdf, Size:1020Kb

Rectorseal 66114 Catalog.Pdf Advanced product development On-site test furnaces Hose stream test Combustion control room Product Innovation Technological Development Testing & Approvals Our family of UL approved In 1995, an on-site fire test Our on-site fire test laboratory FlameSafe® Firestopping laboratory was built for the monitors all phases of test products is specifically designed purpose of conducting UL burns as specified by ASTM to fill voids in construction joints witnessed burns for through- E-814 (UL 1479) or ASTM and around penetrations in penetration and construction joint E-1966 (UL 2079). We have fire-rated walls or floors. Many assemblies. Our laboratory has over 1200 Tested UL systems. have intumescent properties been designated by UL under their Having an on-site UL lab and expand when exposed to Witness Test Data Program for fire speeds the development of heat, forming a high-strength testing to UL 1479 & UL 2079. new firestop products & UL insulating char. systems, allowing quicker response to customer needs. Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 2 Support, training & service Quality control Hands-on training and seminars Intumescent properties Quality Assurance Technical Service Training Seminars You can depend on You can depend on our RectorSeal offers hands-on RectorSeal's expertise & knowledgeable Technical training to properly install a variety 75 years of manufacturing Service team to share their of FlameSafe® Firestop Products experience. Our Quality expertise on any of our over in approved systems. Participants Assurance Team covers 350 products. We are dedicated receive instruction on solutions to each and every aspect of the to providing comprehensive firestopping needs. Students are manufacturing process: from product support to all of our introduced to new products and the initial inspection of raw customers from Architects, watch live fire demonstrations of materials, to on-site monitoring Engineers, Local Inspectors, our products in tested assemblies. throughout production and onto contractors to general consumer. the rigorous final inspection. Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 3 Contractor grade - Code compliant Table of Contents Table Sealants & Sprays Joint & Wrap Strip Bags & Pillows Collars & Sleeves FS 1900 Sealant FS Joint Strip FSB Bags FSD Pipe Collars FS 900+ Sealant FS Wrap Strip FSPIL Pillows FSIS Intumescent Sleeves FS 4000 Silicone Sealant page 11 page 12 page 13 FS 3000 Spray FS 2000 Spray page 6-9 Large Openings FS Mortar FS Composite Sheet page 10 Scan for additional product information. Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 4 Firestopping products & solutions Electrical Outlet Smoke & Acoustic Arc Tape & Sleeves Cable Protection Accessories FS Intumescent Gasket Sealant PVC Arc Tape Cable Coating Wire Mesh FS Intumescent Box Insert RS Caulk Chlorine Free Arc Tape Cable End Caps Safing FSP 1000 Putty RS Spray Arc Sleeves Fiberglass Tying Cable Deck Plugs FSP 1077 Putty Pads page 15 page 16 page 17 Foam Baker Rod page 14 Restraining Collars Caulking Guns page 18 Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 5 FIRESTOP SEALANT Water based intumescent, elastomeric sealant FS 1900 Code Description (Red) Qty. Application r Cures to a seal suitable 66811 10.3 oz. cartridge 12 for installations where dynamic movement is expected rIn the event of 66812 20.2 oz. foil pack 12 fire, FS 1900 sealant expands to fill the 66816 31 oz. cartridge 12 void created by the melting and 66814 1 gal. trowelable pail 4 burning of PVC, CPVC, cc-PVC, ABS, 66815 5 gal. trowelable pail 1 cc-ABS, PEX, insulated pipe and plastic coated cables rPrevents the spread of flames, smoke, hot gases FEATURES and water through penetrations in fire-rated assemblies t &YUSFNFMZJOUVNFTDFOU rFor joints in or between fire-rated assemblies t /POTBHHJOH Recommended for r Metal, insulated, fiberglass and plastic t &YDFQUJPOBMBEIFTJPO pipes r Power and telephone cables r CMU and gypsum top of wall construction joints r Deflection track wall systems t &YDFMMFOUGSFF[FUIBX 3BUFEGPS Apply with Caulking gun Bulk loading gun Trowel t 'MFYJCMFTFU r r r IPVST r Pumping equipment; no mixing required JOBDDPSEBODF t "MMPXTEZOBNJDNPWFNFOU XJUIUIF "45.& t 4BGFBOEFBTZUPVTF 6- 6- t 3BUFEGPS IST 6-$4 t 70$$PNQMJBOU UFTU TUBOEBSET t 1BJOUBCMF Sound USBOTNJTTJPO 45$ UFTUFEJO BDDPSEBODF XJUI"45. & Caulking guns sold separately. Page 16 Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 6 FIRESTOP SEALANT Water based elastomeric sealant FS 900+ Code Description (Red) Qty. Application r Cures to form a flexible 66831 10.3 oz. cartridge 12 shield rIn the event of a fire it will 66832 20.2 oz. foil pack 12 prevent the spread of flames and smoke through penetrations in fire-rated 66834 31 oz. cartridge 12 assemblies rFor joints in or between 66835 5 gal. trowelable pail 1 fire-rated assemblies 66836 5 gal. self-leveling pail 1 Recommended for r Metal, insulated, fiberglass and plastic pipes rCable and Code Description (Gray) Qty. HVAC penetrations r Concrete 66855 5 gal. trowelable pail 1 floor-to-floor, floor-to-wall and wall-to-wall r Concrete rCMU and gypsum head of wall applications requiring dynamic movement FEATURES Caulking gun Bulk loading gun Trowel t 7FSTBUJMFBOEFDPOPNJDBM Apply with r r r rPumping equipment; no mixing required t /POTBHPS4FMGMFWFMJOHHSBEFT t &YDFMMFOUBEIFTJPO t "MMPXTEZOBNJDNPWFNFOU 5FTUFEUP 6- t 'MFYJCMFTFU "45.& Self-Leveling 6- t /P70$hT OPOUPYJD Formula "45.& t &BTZDMFBOVQ & 6- t -PXPEPS "45.& t *OUFSJPSHSBEF Sound t 1BJOUBCMF USBOTNJTTJPO 45$ t 6QUPISGJSFSBUJOH Non-Sag Formula UFTUFEJO available in Red or Gray BDDPSEBODF XJUI"45. & Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 7 FIRESTOP SEALANT Silicone moisture resistant elastomeric sealant FS 4000 Code Description (Gray) Qty. Application r Use to seal wall 66866 10.15 oz. cartridge 12 and floor penetrations for electrical, plumbing, pipe, tele-comm and 66870 5 gal. trowelable pail 1 perimeter barrier penetrations r Cures to form a flexible moisture resistant shield r In the event of a fire FEATURES it will prevent the spread of flames, t .PJTUVSFSFTJTUBOU smoke, gas and water through t 'MFYJCMFTFU penetration openings r For joints in or between fire-rated assemblies t "MMPXTEZOBNJDNPWFNFOU t /POTMVNQGPSNVMB Recommended for r EMT r Semi-rigid and rigid conduit rSteel pipe rWall to decking transition joints rWall to floor 5FTUFEBUB t 6TFCPUIWFSUJDBMMZPSIPSJ[POUBMMZ minimum transition joints rWall to wall control joints rFloor-to-floor control JODIFT t &YDFMMFOUBEIFTJPO joints rFire rated gypsum wallboard partitions rConcrete block 1B XBUFS QPTJUJWFQSFT t *OUFSJPSFYUFSJPSHSBEF or concrete walls and concrete floors TVSF JOBDDPSEBODF Apply with r Caulking gun r Trowel r Pumping equipment; XJUI6- no mixing required and "45.& UFTUTUBOEBSET See ordering chart for container sizes available. Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 8 FIRESTOP SPRAY Sprayable water based elastomeric sealant FS 3000 Code Description (Red) Qty. Application r Sprays on and cures 66871 5 gal. pail 1 to form a flexible, water resistant membrane preventing the spread of Code Description (Beige) Qty. flames, smoke, hot gases and water through construction joints 66872 5 gal. pail 1 and curtain wall assemblies Recommended for r CMU and gypsum head of wall applications requiring FEATURES dynamic movement r Curtain wall t &BTZTQSBZBQQMJDBUJPO perimeter r Metal pipes r HVAC penetrations r Concrete floor-to-floor, t &YDFMMFOUBEIFTJPO floor-to-wall applications t 8BUFSSFTJTUBOU Apply with r Spray equipment; t 'MFYJCMFTFU no mixing required t "MMPXTEZOBNJDNPWFNFOU t IPVSBQQSPWBM t *OUFSJPSFYUFSJPSHSBEF 3BUFEGPS t &BTZDMFBOVQ IPVST JOBDDPSEBODF t /P70$hT OPOUPYJD XJUIUIF "45.& t -PXPEPS 6- 6- t 1BJOUBCMF UFTU TUBOEBSET Sound USBOTNJTTJPO 45$ UFTUFEJO BDDPSEBODF XJUI"45. & Sprayable firestop mastic sealant FS 2000 Code Description (Red) Qty. Application r Sprays on and 66861 5 gal. pail 1 cures to an elastomeric membrane seal preventing the spread of flames, FEATURES smoke, hot gases and water through construction t &BTZTQSBZBQQMJDBUJPO joints, curtain wall assemblies t 8BUFSCBTFE and general construction gaps t &BTZDMFBOVQ and voids r Economical means t 'MFYJCMF&MBTUPNFSJD of installation on long joint runs t IPVSBQQSPWBM Recommended for t "MMPXTEZOBNJDNPWFNFOU r Top of wall r Curtain wall t 1BJOUBCMF perimeter r Expansion control r HVAC ductwork r Deflection track wall systems Apply with r Spray equipment; no mixing required Contact: RectorSeal® P 713-263-8001 800-231-3345 F 713-263-7577 800-441-0051 W http://flamesafe.rectorseal.com 9 MORTAR & SHEETING For large openings FS Mortar Seal Code Description (Beige) Qty. Application r Rapid hardening gypsum/ 66901 22 lbs. bag 1 cement compound for large openings r Sets without shrinking and can form a rigid, Code Description (Beige) Qty. gas tight, fire resistant seal r Can be cut 66902 6 gal. pail 1 or drilled and resealed Recommended for r Power cables Telephone cables FEATURES r Aluminium or steel cable r t (SFBUGPSMBSHFPQFOJOHT trays r EMT r Copper t -PBECFBSJOH Steel Cast iron pipe 5FTUFEUP r r 6- t &BTZUP6TF Apply with "45.& 6-$4 t )JHIZJFMEQFSMC r Trowel or pour t &BTZDMFBOVQ For large openings FS Composite Sheet Code Description Qty. Application r Rigid fire resistive panel used 66930 36” x 36” 1 to seal penetrations and restore the fire rating to floor/ceilings or walls r Made of reinforced, highly intumescent material bonded on one side to a galvanized steel sheet FEATURES r Ideal for clean room t -JHIUXFJHIU applications t 5IJOOFSTIFFUT t 3FFOUFSBCMF t /P70$hT US Patent No.
Recommended publications
  • Firestopping & Smoke Seals 1 General
    SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of this section of the specifications to establish a single, competent source to be responsible for providing all labour, materials, products, equipment and services, to supply and install the firestopping and smoke seal work for the entire project. 1.1.3 SUMMARY A. Provide firestop systems consisting of a material, or combination of materials installed to retain the integrity of fire-rated construction by maintaining an effective barrier against the spread of flame, smoke, and/or hot gases through penetrations, blank openings, construction joints, or at perimeter fire containment in or adjacent to fire-rated barriers in accordance with the requirements of the Building Code for this project. B. Firestop systems shall be used in locations including, but not limited to, the following: 1. Penetrations through fire-resistance-rated floor and roof assemblies requiring protected openings including both empty openings and openings that contain penetrations. 2. Penetrations through fire-resistance-rated wall assemblies including both empty openings and openings that contain penetrations. 3. Membrane penetrations in fire-resistance-rated wall assemblies where items penetrate one side of the barrier. 4. Joints in fire-resistance-rated assemblies to allow independent movement. 5. Perimeter Fire Barrier System between a rated floor/roof and an exterior wall assembly. 6. Joints, through penetrations and membrane penetrations in Smoke Barriers and Smoke Partitions. 1.2 RELATED SECTIONS 1.2.1 Related Sections to this Section include: 1.
    [Show full text]
  • Outlet Putty Pads Specifications Section 07840 - Firestopping Part 1 - General
    OUTLET PUTTY PADS SPECIFICATIONS SECTION 07840 - FIRESTOPPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes: Through penetration firestops and smoke-stops for all fire-rated bearing and non- bearing wall and floor assemblies, both blank (empty) and those accommodating penetrating items such as cables, conduits, pipes, ducts, etc. not covered in Division 15 and 16 Sections. Membrane penetration protection for fire-rated walls. Architectural/Construction joint firestops within walls, floors, or the intersection of floors to exterior walls, or the intersection of top of walls to ceilings. Top of wall firestopping in all fire-rated partitions. Top of wall and construction joint smoke-stopping in all smoke partitions. B. Related Sections include the following: Division 15 Sections specifying duct and pipe penetrations and firestopping for those penetrations. Division 16 Sections specifying cable and conduit penetrations and firestopping for those penetrations. 1.3 REFERENCES: A. American Society For Testing and Materials Standards (ASTM): ASTM E84: Standard Test Method For Surface Burning Characteristics of Building Materials. ASTM E814: Standard Test Method For Fire Tests of Through-Penetration Sales and support: (800) 397-8791 | www.soundproofingcompany.com | [email protected] Firestops. ASTM E1966: Test Method For Resistance of Building Joint Systems. ASTM E1399: Test Method for Cyclic Movement and Measuring Minimum and Maximum Joint Width. ASTM E119: Methods of Fire Tests of Building Construction and Materials. B. Underwriters Laboratories Inc.: UL 263: Fire Tests of Building Construction and Materials.
    [Show full text]
  • Summaries of Center for Fire Research Grants and In-House Programs - 1984
    4 NAT'L INST. OF STAND & TECH NBS REFERENCE PUBLICATIONS AlllOb 0371LD NBSIR 85-3136 Summaries of Center for Fire Research Grants and In-House Prog rams - 19 8 Sonya M. Cherry, Editor U S. DEPARTMENT OF COMMERCE National Bureau of Standards National Engineering Laboratory Center for Fire Research Gaithersburg, MD 20899 April 1985 Final Report U S. DEPARTMENT OF COMMERCE -ATIONAL BUREAU OF STANDARDS 100 ,U56 85-3136 1985 NATIONAL BUREAU OF STANDARDS LIBRARY NBSIR 85-3136 SUMMARIES OF CENTER FOR FIRE RESEARCH GRANTS AND IN-HOUSE PROGRAMS - 1984 Sonya M. Cherry, Editor U S. DEPARTMENT OF COMMERCE National Bureau of Standards National Engineering Laboratory Center for Fire Research Gaithersburg, MD 20899 April 1985 Final Report U.S. DEPARTMENT OF COMMERCE, Malcolm Baldrige, Secretary NATIONAL BUREAU OF STANDARDS. Ernest Ambler. Director TABLE OF CONTENTS Page ABSTRACT 1 CENTER FOR FIRE RESEARCH PROGRAMS Ad Hoc Working Group of Mathematical Fire Modeling 2 Compartment Fire Modeling 3 Exploratory Fire Research 8 Fire Growth and Extinction 14 Fire Performance and Validation 20 Fire Safety Performance 24 Fire Toxicology 28 Furnishings Flammability 34 Smoke Hazard 37 GRANTS AND CONTRACTS American Institute of Architects A Computerized Model for the Simulation of General Fire Emergency Evacuations 40 Brown University Soot Dynamics in Flames 43 Brown University Study of Effects of Material Properties on Flaming Combustion of Charring Fuels 47 California Institute of Technology Experimental Study of Environment and Heat Transfer in a Room Fire 51 Case Western Reserve University Experimental and Analytical Study of Fire Sprinkler Scaling Laws 55 Case Western Reserve University Flame Spread and Spread Limits 58 l Page Clemson University Ternary Reactions Among Polymer Substrate- Organohalogen-Ant imony Oxides in the Condensed Phase Under Pyrolytic, Oxidative and Flaming Conditions 60 Colorado School of Mines Characterization of Aerosols from Fires 63 Factory Mutual Research Corp.
    [Show full text]
  • The Hose Stream Test
    The Hose Stream Test What is the Hose Stream Test? The hose stream test is an integral part of many fire testing standards. ASTM E 119, ASTM E 814/UL 1479, and ASTM E 1966/UL 2079 are all standards that affect the firestopping industry. All three standards require a hose stream test. What's the history of the Hose Stream? In the late 1890's, cast & wrought iron were commonly used in construction. Unlike steel, they failed in a brittle manner when heated in a fire, creating a risk for firefighters who were in the wrong place at the wrong time. As a result, the hose stream was created to test the integrity of these support members (columns/beams). In 1918, the first edition of ASTM standard E 119--then numbered C19, Standard Test Method for Fire Tests of Building Construction and Materials-- included a hose stream test to measure a material's integrity. Because ASTM E 119 includes the hose stream test as acceptance criteria of assemblies, it is considered applicable to fire stops as well. What is the intent of the Hose Stream? The hose stream serves as an indicator for two important attributes: 1) the integrity of a fire stop or assembly during fire exposure and 2) the overall reliability of the material to perform its intended function. For firestop systems it is important to obtain an indication of performance integrity. A firestop system that loses its integrity can allow the spread of fire by creating passages for flames and hot gases to propagate from one side of a rated assembly to another.
    [Show full text]
  • Hilti Firestop Binder, CP
    Data Sheet HILTI CP 617 Intumescent acoustic putty pad The enclosed pages are taken from the Hilti Firestop Systems Manual Edition April 2011 Supported by additional standard details For Material Safety data sheets visit the technical library at www.hilti.co.uk/cfs Hilti (Gt Britain) Ltd TECHNICAL ADVISORY SERVICE TELEPHONE 0161 886 1144 Quality Management System Certification Standard: ISO 9001:2008 Issued by: The Swiss Association for Quality and Management Systems SQS. Registration No: 12455 (The current certificate can be downloaded from www.hilti.co.uk) Field of activity: Market Organisation. Note: The certificate of Hilti (Gt. Britain) Ltd. is a sub-certificate to the master certificate of Hilti Aktiengesellschaft,FL-9494 Schaan with the field of activity: Research, Development, Manufacturing, Sales and Service. Hilti (Gt. Britain) Limited, Telephone: 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY 0800 886 100 Data Sheet Don’t just use Hilti Firestop Products, use our Hilti Accredited Firestop Contractors It is the combination of a quality conscious and third party accredited manufacturer working in close co-operation with a selected group of third party accredited installers that can offer you the best value. Here are some of the benefits available to you by using this co-operation:- Reduce your liability; liability that comes from poor or incorrect installation and performance of products. Efficient Project Management based on the co-operation of a specialised manufacturer with a specialist contractor Commercially designed, effective Fire Protection solutions Products that adhere to 3rd party product conformity schemes such as FM, UL and Certifire. These approvals are an assurance of product and manufacturer quality, they can also have an influence on the building insurance premium reducing the service costs of the building.
    [Show full text]
  • Circuit Integrity and Fuel-Like Protection and How to Avoid This
    Circuit Integrity and Fuel-line Protection AND How to Avoid This Common Firestop Deficiency Presented by; Eric De Amorim, National Sales Manager at STI Firestop & Tim Mattox, Field Engineer Central Regions NA Circuit Integrity and Fuel- line Protection What does it mean? Electrical circuit functionality during a fire Electrical power is essential for the continued operation of various types of fire safety related equipment under fire conditions. Fire safety equipment includes fire pumps, fire alarm signaling equipment, elevators, alarms and industrial process control equipment. The National Electrical Code addresses the importance of maintaining the circuit functionality by requiring protection from potential damage by fire, structural failure or operational accident in Article 695 for fire pumps, Article 700 for emergency systems and Article 760 for fire alarm systems. Protection Systems Carrying Combustible Liquids Local building codes require fuel lines feeding emergency generators and fire pump drivers within buildings to be protected for 2 hours. This ensures the fuel pipe system will maintain its integrity in the event of fire. Different fire protection methods can be used to address circuit integrity and fuel-like protection 1. Concrete encasement 2. Fire-rated gypsum enclosures 1. Not practical for conduits penetrating walls 1. Space constraints 2. In some cases concrete prevents future access Endothermic Wrap Solutions – An Increasingly Popular Solution These wrap systems provide a cooling effect. 1. Tested solution, provides up to 3 hour of protection. 2. Practical – when space is an issue OR in overhead applications. 3. Flexible material – easy to install, even on small diameter conduits. 4. May also be used to achieve equal F&T Ratings on Penetration Firestop Systems.
    [Show full text]
  • Process Equipment for Passive Fire Protection Manual
    Fire Protection for Process Equipment hydrocarbon and jet fire protection THERMAL CERAMICS FM Process Equipment_Jan2020_ENG.indd 1 5/5/2020 7:05:32 PM THERMAL CERAMICS THERMAL CERAMICS ABOUT MORGAN ADVANCED MATERIALS ABOUT MORGAN ADVANCED MATERIALS LISTED ON THE LONDON STOCK EXCHANGE OVER MANUFACTURING IN SELLING INTO >30 >10 0 9000 COUNTRIES COUNTRIES EMPLOYEES Morgan Advanced Materials is a global engineering company offering world-leading competencies in materials science, specialist manufacturing and applications engineering. Morgan Advanced Materials is a global engineering company offering world-leading competencies in materials science, We focus specialistour resources manufacturing on the delivery and applications of products engineering. that help our customers to solve technically challenging Problems, enabling them to address global trends such as We focus our resources on theenergy delivery demand, of products advances that in help healthcare our customers and environmental to solve technically sustainability. challenging Problems, enabling them to address global trends such as energy demand, advances in healthcare and environmental sustainability. What differentiates us? Advanced material science and processingWhat differentiates capabilities. us? Extensive applications engineering experience. Advanced material science andA processingstrong history capabilities. of innovation Extensive and reinvention.applications engineeringConsistent andexperience. reliable performance. A strong history of innovation and reinvention. Consistent
    [Show full text]
  • Fire Test Program – Executive Summary
    Structural and Nonstructural Building System Performance During Earthquake and Post-Earthquake Fire Fire Test Program – Executive Summary Department of Fire Protection Engineering Worcester Polytechnic Institute Worcester, MA 01609 USA http://www.wpi.edu/academics/fpe.html BNCS Test Series Fire Test Program – Executive Summary NOTICE This Report was prepared by Brian Meacham, Jin-Kyung Kim and Haejun Park as part of the building nonstructural components and systems (BNCS) project (http://bncs.ucsd.edu/index.html). Information presented in this report was obtained by the BNCS team during the test program. Reasonable attempts were made to verify the accuracy of the information provided, referenced and summarized in this report. However, neither the authors, sponsoring institutions or agencies, nor any person acting on their behalf: a. Makes any warranty, express or implied, with respect to the use of any information, apparatus, method or process disclosed in this report, or that such use may not infringe upon privately owned rights; or b. Assumes any liabilities of whatsoever kind with respect to the use of, or damage resulting from use of, any information, apparatus, method or process disclosed in this report. Any summaries, opinions, findings, conclusions or recommendations expressed in this report are those of the authors and do not necessarily reflect project sponsors, institutions, agencies or organizations. 2 BNCS Test Series Fire Test Program – Executive Summary In April and May 2012, a series of landmark full-scale experiments were conducted on and within a 5-story reinforced concrete frame test specimen, with floor plates measuring 6.6 meters by 11 meters (21.5 feet by 36 feet), which was erected on the nation’s largest outdoor shake table at the Englekirk Structural Engineering Center at the University of California, San Diego.
    [Show full text]
  • PASSIVE FIRE PROTECTION SYSTEMS Justification of Performance for Road Tunnel Structures
    Les guides PASSIVE FIRE PROTECTION SYSTEMS Justification of performance for road tunnel structures Updated version of March 2017 Centre d'Études des Tunnels www.cetu.developpement-durable.gouv.fr DISCLAIMER This guide is the result of a process of synthesis, methodological assessment, research and feedback, either carried out or commissioned by CETU. It is designed to be used as a reference for the design, construction and operation of underground structures. As the guide takes stock of the state of the art at a particular time, the information it contains may become outdated, either due to developments in technology or regulations, or to developments of more efficient methods. 2 Les guides Passive fire protection systems Justification of performance for road tunnel structures Updated version of March 2017 Centre d’Études des Tunnels 25, avenue François Mitterrand Case n° 1 69674 BRON - FRANCE Ph. +33 (0)4 72 14 34 00 Fax +33 (0)4 72 14 34 30 [email protected] www.cetu.developpement-durable.gouv.fr 3 TABLEOFCONTENTS Foreword 5 Definitions 6 1Introduction 7 2Generalprinciplesforfireprotection 8 3Passivefireprotectionsystemsandtheirimplementationon-site 9 3.1 Board type or sprayed type fire protection materials 9 3.2 Construction Products Regulation and CE marking 9 3.3 Consideration of the entire fire protection system 10 3.4 On-site application 11 4Acceptanceconditionsforpassivefireprotectionsystemsontheconstructionsite 12 4.1 “Conventional” testing according to European standards 13 12 4.2 Overviews and current practices 12 4.3 Developments and recommendations in the context of HCM tests 13 4.4 Validity and acceptability of fire resistance tests 13 5Bibliographicreferences 15 APPENDICES AAppendixA–HCMTESTMETHOD 16 BAppendixb–Documentstoproduce/torequest 24 CAppendixC–Optionaladditionaltesting 25 4 FOREWORD This document supersedes the guide on “Passive fire protection • the duration of a HCM test has been specified in function systems” published in March 2013.
    [Show full text]
  • Fireproofing for Hydrocarbon Fire Exposures
    GAP.2.5.1 GAP Guidelines June 1, 2000 A Publication of Global Asset Protection Services FIREPROOFING FOR HYDROCARBON FIRE EXPOSURES INTRODUCTION A hydrocarbon fire inflicts initial damage by directly heating metal beyond its limits and destroying the equipment or building. Even more damage occurs when the fire spreads due to the collapse or rupture of vessels caused by metal failing under the initial fire exposure. One way to mitigate this damage is to install fireproofing. Fireproofing is discussed in Section 6, Chapter 5 of the NFPA Handbook.1 This GAP Guideline outlines the position of Global Asset Protection Services (GAP Services) on fireproofing for hydrocarbon fire exposures. Fireproofing of structural steel exposed to hydrocarbon fires has been used for many years with varying degrees of success. Conventional concrete, lightweight concrete and brick gave a satisfactory degree of protection with little concern for the exact time-protection rating beyond the stipulation that designated thicknesses of these materials be installed. In the past 25 years, proprietary fireproofing products were developed. The protection times for these new materials needed to be determined. Building materials or systems are tested for performance under fire conditions in a carefully controlled furnace. The standard time-temperature curve is defined in ASTM E-1192 and represents a wood fire that does not reach 3400°F (1870°C) for 4 hrs (see Figure 1). Since hydrocarbon fires reach that temperature almost instantly, the ASTM E-119 curve does not adequately predict the performance of fireproofing materials under hydrocarbon fire exposure. Underwriters Laboratories developed the UL 17093 test procedure based on hydrocarbon fire exposure.
    [Show full text]
  • Strides in Fire Safety for Mass Wood Timber Buildings Tall Mass Wood Timber Buildings Have Captured the Design Imagination of North America
    Kaiser Group and Path Architecture designed Carbon 12. At the time it was built it was the tallest mass timber and cross-laminated timber building in the country. CREDIT: ANDREW POGUE Strides In Fire Safety for Mass Wood Timber Buildings Tall Mass Wood Timber buildings have captured the design imagination of North America. As these buildings are poised to go taller, the leading firestop company, Hilti North America, has stepped in with innovative ways to help promote fire safety. + www.greenbuildermedia.com “The question for Hilti became, How long can a structural wood construction element withstand a fire within a building? Hilti has focused on this gray area because no approved firestop solutions existed.” —Neal Clemens, Marketing and Product Manager, Fire Protection, Hilti North America wood-built future in tall buildings. ability to approach tall building from a From 2014 to the end of 2018, the modular standpoint results in reduced number of U.S. mass timber projects manpower and many other characteristics grew from fewer than 20 to well over that make CLT attractive to the building 400, reports nonprofit WoodWorks. And industry—and it’s not going away.” Forterra, a land conservation nonprofit, says that demand for CLT, which is used WITH INNOVATION COMES in Tall MWT projects, is expected to RESPONSIBILITY double every five years into the future. Perhaps the most important (and misun- The exponential growth of MWT derstood) aspect of MWT is its fire perfor- is good news for the building industry mance. People often think of wood as a because the technology offers faster quick-igniting object, like kindling.
    [Show full text]
  • Fireworthiness of Transport Aircraft Interior Systems
    FIREWORTHINESS OF TRANSPORT AIRCRAFT INTERIOR SYSTEMS John A. Parker and D. A. Kourtides Ames Research Center INTRODUCTION This paper presents an overview of certain aspects of the evaluation of the fireworthiness of air transport interiors. First, it addresses the key materials question concerning the effect of interior systems on the survival of passengers and crew in the case of an uncontrolled transport aircraft fire. Second, it examines some technical opportunities that are available today through the modification of aircraft interior subsystem components, modifica- tions that may reasonably be expected to provide improvements in aircraft fire safety. Cost and risk benefits still remain to be determined. Space permits only the discussion of three specific subsystem components: interior panels, seats, and windows. By virtue of their role in real fire situations and as indicated by the results of large-scale simulation tests, these components appear to offer the most immediate and highest payoff possible by modifying interior materials of existing aircraft. These modifications have the potential of reducing the rate of fire growth, with a consequent reduction of heat, toxic gas, and smoke emission throughout the habitable interior of an aircraft, whatever the initial source of the fire. It will be shown that these new materials modifications reduce the fire hazard not only because of their unique ablative properties, which help to contain or isolate the fire source, but also because there is a significant reduction in their characteristic flame spread, heat release, and smoke and toxic gas emissions. SURVIVABILITY CRITERIA FOR AIRCRAFT FIRES Significantly destructive fires, which have been encountered by transport aircraft, can be classified generally into three kinds (fig.
    [Show full text]