Your Introductory Eye Examination

Total Page:16

File Type:pdf, Size:1020Kb

Your Introductory Eye Examination YOUR INTRODUCTORY EYE EXAMINATION At Eyesite we are committed to most thorough examination available. providing a comprehensive and In our customer feedback 98% of our personal eye examination service. customers strongly agreed that their With our clinical expertise and eye examination was extremely investment in the latest technology thorough and 94% would definitely and equipment, we can ensure the recommend us to friends and family. Join us online: www.eyesite.co.uk @Eyesite /Eyesiteopticians WELCOME TO EYESITE As a new patient to Eyesite we believe that you deserve the best possible eyecare. We call you patients because we are here to make sure you are cared for and looked after throughout your visit. At Eyesite, we offer a range of comprehensive eye examinations based on the technology used during your exam and the time spent with your optometrist evaluating your eyecare needs. As this is your first examination with us we would like you to experience our most thorough exam for the cost of our standard exam so you will be booked in for our Introductory Advanced Gold Examination. During your exam you will spend approximately an hour with your experienced optometrist as they guide you through your visit. This means we can take baseline readings of your eye health to compare against next time you come in. It also allows us to demonstrate all the technology we can use and what it tells us about your eyes. Your optometrist will then discuss all your results & visual needs and recommend the most suitable IMAGING TECHNOLOGY eyecare solution. The history and symptoms and eye health assessment allows us to look for signs of eye disorders such as glaucoma or cataract and can also uncover issues such as diabetes or high blood pressure. OPTICAL COHERENCE OPTOMAP TOMOGRAPHY (OCT) Optomap gives a wider angle digital scan of the The table below easily demonstrates the difference between the available exams. OCT is a new imaging technique that offers a retina than fundus photography. This enhances ‘high-definition’ detailed cross-sectional image of our ability to detect even the earliest signs of Introductory Advanced Advanced Extended NHS disease and health issues including heart Eye Gold Eye Eye Eye the back of the eye. The OCT is useful in the Examination Examination Examination Examination Examination diagnosis and management of many conditions disease, hypertension, diabetes and strokes. The scan causes no discomfort, nothing touches History, Symptons & General Health Discussion including age-related macular degeneration and glaucoma. your eye and is recommended to all patients Eye Health assessment including children. The digital image is captured The OCT works in a similar way to in seconds and is immediately available for your Eye Pressure check ultrasound and is able to take 128 individual optometrist to review. scans and create a 3 dimensional view of either Vision Assessment FUNDUS PHOTOGRAPHY the optic nerve (the nerve that sends a signal to State-of-the-art digital retinal photographs are Visual Field Assessment the brain) or the macula (central vision area). This enables us to understand, detect and used to record images of the central portion of Spectacle Discussion monitor eye problems easily. The scan is the retina each time you visit us. completely painless, quick to perform and This enables us to compare the results from Other Visual Solutions Discussion nothing touches the eye. previous tests and detect any tiny changes quickly in the future. Retinal Imaging of back of the eye Optomap Retinal Scan Optical Coherence Tomography (OCT) Imaging OCT IMAGING OCT IMAGING OPTOMAP FUNDUS Contact Lens Experience Included* 60 60 40 30 20-30 Time spent with your Optometrist mins mins mins mins mins *Contact Lens experiences can also be booked free of charge as a separate appointment after any examination. Private Patient Fee £42.00 £94.00 £68.00 £42.00 N/A *Contact Lens experiences can also be booked free of charge as a separate appointment after any examination. HAVE YOU THOUGHT ABOUT WEARING CONTACT LENSES? If you would like an alternative to wearing your glasses or if you’ve thought about wearing contact lenses before but have been nervous or unsure or even if it’s a completely new idea you can have a Contact Lens Experience at the same time as your eye exam. Your Optometrist will discuss which type of contact lens will be CHILDREN & YOUNG most suitable for you, your lifestyle and your vision and you can see and feel a lens, we can PEOPLE also demonstrate how easy it is to apply and We recommend that all under 19’s have an remove contact lenses. If you are keen to optomap retinal scan. If you are under 19 and in become a contact lens wearer we can then book full time education the NHS will fund your you in for a Contact Lens Fitting. regulation sight test and there would normally be an additional charge for your optomap. If you are new to Eyesite we would like the opportunity NHS PATIENTS to show you the benefits of this fantastic If you are entitled to NHS help, we still technology, so on your 1st visit we will include recommend that you choose the Introductory optomap for no extra charge as part of your Advanced Gold Exam. Your private fee will be under 19’s Introductory Eye exam. reduced by the NHS contribution. If you prefer we can carry out an NHS test, paid for by the NHS. To find out if you are entitled to NHS help please ask in practice or visit our website at www.eyesite.co.uk. TO BOOK YOUR APPOINTMENT Please download our app, go to www.eyesite.co.uk, visit your nearest practice or call us on one of the numbers below. Remember to bring your current spectacles or contact lenses with you to your appointment. BRIGHTON READING OXFORD (01273) 724111 (0118) 9509098 (01865) 242300 WEYBRIDGE WINCHESTER WOKING (01932) 859889 (01962) 864446 (01483) 765273 Join us online: www.eyesite.co.uk @Eyesite /Eyesiteopticians.
Recommended publications
  • A Comprehensive Survey on Various Biometric Systems
    International Journal of Applied Engineering Research ISSN 0973-4562 Volume 13, Number 5 (2018) pp. 2276-2297 © Research India Publications. http://www.ripublication.com A Comprehensive Survey on Various Biometric Systems T.Sabhanayagam 1, Dr. V. Prasanna Venkatesan2 and Dr. K. Senthamaraikannan3 1 Research Scholar, Center for Computer and Information Technology Engineering, Manonmaniam Sundaranar University, Tirunelveli, Tamilnadu, India. 1And Assistant Professor, School of Computing, SRMIST, Chennai 1Orcid: 0000-0002-9782-7068 2 Dr.V.Prasanna Venkatesan, Proof & Head, Dept. of Banking Technology, Pondicherry University, Puducherry, India. 3 Dr. K.Senthamaraikannan, Prof & Head, Dept. of Statistics, Manonmaniam Sundaranar University, Tirunelveli, Tamilnadu, India. Abstract Biometrics gains significant importance in this technical world and it means analysis of biological data. It is defined as the technology of analyzing individual person based on physiological, behavioural or morphological traits such as face, fingerprint, iris, retina, voice, and signature etc,. It is possible to establish one’s identity with the help of biometric techniques. Today biometric have been successfully deployed in various fields like forensic science, security, identification and authorization system. For the last three decades, lot of research work has to be carried out for the growth of biometric system based on fingerprint, voice, iris, face, etc, but recently new biometrics has been come up. To provide a comprehensive survey, this paper presents an
    [Show full text]
  • Optical Imaging of the Chorioretinal Vasculature in the Living Human Eye
    Optical imaging of the chorioretinal vasculature in the living human eye Dae Yu Kima, Jeff Finglera, Robert J. Zawadzkib, Susanna S. Parkb, Lawrence S. Morseb, Daniel M. Schwartzc, Scott E. Frasera,1, and John S. Wernerb,1 aBiological Imaging Center, California Institute of Technology, Pasadena, CA 91125; bDepartment of Ophthalmology and Vision Science, University of California, Davis, Sacramento, CA 95817; and cDepartment of Ophthalmology, University of California, San Francisco, CA 94143 Edited* by Napoleone Ferrara, University of California, San Diego, La Jolla, CA, and approved July 9, 2013 (received for review April 18, 2013) Detailed visualization of microvascular changes in the human retina cells, as well as atrophy of the underlying CC and choroidal is clinically limited by the capabilities of angiography imaging, a vessels (4–6). GA regional identification is typically accomplished 2D fundus photograph that requires an intravenous injection of using autofluorescence imaging techniques, which depend on fluorescent dye. Whereas current angiography methods enable lipofuscin accumulation within RPE cells associated with this visualization of some retinal capillary detail, they do not ade- disease, but the current clinical imaging methods are limited in quately reveal the choriocapillaris or other microvascular features detecting early morphological changes in the choriocapillaris beneath the retina. We have developed a noninvasive microvas- (7, 8). An improved understanding of the progression of GA cular imaging technique called phase-variance optical coherence and its underlying mechanisms is important to develop potential tomography (pvOCT), which identifies vasculature three dimen- therapeutic targets for intervention, and diagnostic tools capable sionally through analysis of data acquired with OCT systems. The of observing the key features of atrophic AMD are critical for fulfilling this goal.
    [Show full text]
  • Eye Based Authentication: Iris and Retina Detection
    The University of Saskatchewan Department of Computer Science Technical Report #2011-04 Eye Based Authentication: Iris and Retina Recognition Minhaz Fahim Zibran 2009 Department of Computer Science The University of Saskatchewan, Canada Abstract Biometric authentication comes in play to release the users from the difficulties of remembering and protecting passwords as required by traditional authenti- cation systems. Among all the biometrics in use today, eye biometrics (iris and retina) offers the highest level of uniqueness, universality, permanence, and ac- curacy. Despite these convincing properties of iris and retina biometrics, they have not been in widespread use. Moreover, humans have more or less a natural ability to recognize individuals staring at the person's eye. So, it is interesting to investigate to what extent the eye based biometrics (iris and retina recog- nition) are capable of distinguishing individuals, and what factors are there, which hinder the adoption of these technologies. This report presents a comparative study on iris and retina biometrics based on literature review. The study aims to investigate the two biometrics, conduct a comparative analysis in a fair level of technical detail, and identify the challenges and future possibilities towards their ubiquitous use. In presenting the findings, the study contributes in three ways: (1) This report may serve as a tutorial of eye biometric for those who are new in the area, (2) The comparison between iris and retina biometrics will be helpful for individuals and organizations in choosing the appropriate eye biometric for use in their context. (3) The technical, security, and usability issues identified by the study reveal avenue for further research in order to improve eye biometrics.
    [Show full text]
  • Diabetic Retinopathy by the Numbers a Guide to Following and Educating Patients LACRIMAL OCCLUSION ■ Who Face This Threatening Diagnosis, P
    REVIEW OF OPTOMETRY Earn 2 CE Credits: Can You Identify These Vitreous Anomalies?, p. 94 ■ VOL. 153 NO. 6 June 15, 2016 www.reviewofoptometry.com ■ JUNE 15, 2016 ■ ANNUAL 7th Annual Retina Report RETINA REPORT Diabetic Retinopathy By the Numbers ■ A guide to following and educating patients LACRIMAL OCCLUSION who face this threatening diagnosis, p. 36 • Food for Thought: Diet, Genetics and AMD, p. 48 • The Dilation Dilemma p. 54 • Managing Patients with ■ VITREOUS ANOMALIES Hypertensive Crisis, p. 58 ■ VIRAL CONJUNCTIVITIS 125 YEARS Plug the Drain with Lacrimal Occlusion, p. 70 | Claim Victory Over Viral Conjunctivitis, p. 78 001_ro0616_fc.indd 1 6/9/16 9:57 AM We call it our fundamental business truth: 1 20/200 Your success is essential to Our success. When your practice grows and flourishes, so does ours. At Johnson & Johnson Vision Care, we have operated according to this simple, but profound, principle for over 30 years. And it is the inspiration and 2 20/100 energy behind every year of our 3 decades of Global leadership in the contact lens marketplace. But history tells only a small part of the story. It is what we will do together in partnership over 3 20/70 the next 3 decades that will truly change the very meaning of vision care. Our commitment to innovation is unwavering. 4 20/50 But at the center of all of the R & D eff orts—be they technological, educational, or commercial in nature— is our commitment to advancing the eye care profession. 5 20/40 We thank you for your partnership and look forward to the continued journey together.
    [Show full text]
  • Did I Do That? a Current Analysis of Biometric Technologies by Jalaynea A
    Did I Do That? A Current Analysis of Biometric Technologies by Jalaynea A. Cooper Introduction Have you ever wondered about a bank transaction that you don’t remember doing or losing your bank credit card and hoping that no one will use it? There are several security authentication options that can be taken in order to assure that no one else claims to be you. One in particular is Biometrics. What is Biometrics? Biometrics are automated methods of recognizing a person based on physiological or behavioral characteristics.2 Physiological characteristics are those that we are born with such as fingerprint, hand geometry, or iris. The way a person speaks or a person’s signature is classified as behavioral characteristics. We will explore some of the man types of physiological and behavioral biometrics below. Physiological Characteristics Fingerprint Fingerprints like the one in Figure 1 can be used by matching 3 the minutiae or emulating a traditional police method . No two fingers are alike due to not having the same dermal ridge. Figure 1 The fingerprint biometric identification scheme is the analysis of an individual’s unique fingerprints. 13 It is the oldest and most widely recognized biometric marker. 18 More biometric devices for fingerprints are available to use than any other biometric system. 3 • How does the fingerprint technology work? Fingerprints are made up of ridges and valleys on the surface of the finger. Segments on the upper skin layer are the ridges and the lower skin layers are the valleys. Minutia points are formed by ridges. The fingerprint is determined unique by the pattern of the ridges and minutiae points.
    [Show full text]
  • Optical Imaging of the Chorioretinal Vasculature in the Living Human Eye
    Optical imaging of the chorioretinal vasculature in the living human eye Dae Yu Kima, Jeff Finglera, Robert J. Zawadzkib, Susanna S. Parkb, Lawrence S. Morseb, Daniel M. Schwartzc, Scott E. Frasera,1, and John S. Wernerb,1 aBiological Imaging Center, California Institute of Technology, Pasadena, CA 91125; bDepartment of Ophthalmology and Vision Science, University of California, Davis, Sacramento, CA 95817; and cDepartment of Ophthalmology, University of California, San Francisco, CA 94143 Edited* by Napoleone Ferrara, University of California, San Diego, La Jolla, CA, and approved July 9, 2013 (received for review April 18, 2013) Detailed visualization of microvascular changes in the human retina cells, as well as atrophy of the underlying CC and choroidal is clinically limited by the capabilities of angiography imaging, a vessels (4–6). GA regional identification is typically accomplished 2D fundus photograph that requires an intravenous injection of using autofluorescence imaging techniques, which depend on fluorescent dye. Whereas current angiography methods enable lipofuscin accumulation within RPE cells associated with this visualization of some retinal capillary detail, they do not ade- disease, but the current clinical imaging methods are limited in quately reveal the choriocapillaris or other microvascular features detecting early morphological changes in the choriocapillaris beneath the retina. We have developed a noninvasive microvas- (7, 8). An improved understanding of the progression of GA cular imaging technique called phase-variance optical coherence and its underlying mechanisms is important to develop potential tomography (pvOCT), which identifies vasculature three dimen- therapeutic targets for intervention, and diagnostic tools capable sionally through analysis of data acquired with OCT systems. The of observing the key features of atrophic AMD are critical for fulfilling this goal.
    [Show full text]
  • Research Article a Novel Retinal Identification System
    Hindawi Publishing Corporation EURASIP Journal on Advances in Signal Processing Volume 2008, Article ID 280635, 10 pages doi:10.1155/2008/280635 Research Article A Novel Retinal Identification System Hadi Farzin,1 Hamid Abrishami-Moghaddam,1 and Mohammad-Shahram Moin2 1 Department of Electrical Engineering, K.N. Toosi University of Technology, Seyed Khandan, 16315-1355 Tehran, Iran 2 Iran Telecommunication Research Center, North Kargar, 14399-55471 Tehran, Iran Correspondence should be addressed to Hamid Abrishami-Moghaddam, [email protected] Received 1 May 2007; Revised 27 December 2007; Accepted 21 February 2008 Recommended by Nikolaos V. Boulgouris This paper presents a novel biometric identification system with high performance based on the features obtained from human retinal images. This system is composed of three principal modules including blood vessel segmentation, feature generation, and feature matching. Blood vessel segmentation module has the role of extracting blood vessels pattern from retinal images. Feature generation module includes the following stages. First, the optical disk is found and a circular region of interest (ROI) around it is selected in the segmented image. Then, using a polar transformation, a rotation invariant template is created from each ROI. In the next stage, these templates are analyzed in three different scales using wavelet transform to separate vessels according to their diameter sizes. In the last stage, vessels position and orientation in each scale are used to define a feature vector for each subject in the database. For feature matching, we introduce a modified correlation measure to obtain a similarity index for each scale of the feature vector.
    [Show full text]
  • Automatic Biometric Recognition Using Artificial Neural Networks
    © 2019 IJRAR May 2019, Volume 6, Issue 2 www.ijrar.org (E-ISSN 2348-1269, P- ISSN 2349-5138) AUTOMATIC BIOMETRIC RECOGNITION USING ARTIFICIAL NEURAL NETWORKS 1Gururaj J.P. , 2Dr. T.A. Ashok Kumar 1HOD & Assistant Professor, 2Associate Professor & Dean Dept. of Computer Science,Government First Grade College, Harihara-577601, Ph.D. Research Scholar, Garden City University, Bangalore, Karnataka, India. Abstract - Personal identification, recognition is a vital problem in any biometric application scenario. Biometrics finds a lot of application in the modern day security aspects whether it may be in industrial sector, defense sector or in domestic sectors. Entry of a person into an organization in the work environment plays a very important role as unauthorized persons if entered into a premises may create a flutter & inviable to some terrorist attacks. Hence, biometrics of an authorized person into the work environment plays a very important role. There are a large number of biometric methods for identification, viz., physiological & behavioural. Some of them are face, fingerprint, iris, voice, hand, thumb, ear, vein, gait, code, password, signature, pattern, palm print, etc... As there are a number of biometric methods for the automatic detection of human beings, retina scan is being considered as the biometric identity in the research work undertaken by us because of a large number of advantages over the other biometric identities. For biometric recognition of a person using retina scans, a number of methods exists in the literature. In this context, Artificial Neural Nets & Convolution Neural Netsmethod aresome of the methods that could be used for biometric recognition of humans.
    [Show full text]
  • Deep Ensemble Learning Based Objective Grading of Macular Edema by Extracting Clinically Significant Findings from Fused Retinal
    sensors Article Deep Ensemble Learning Based Objective Grading of Macular Edema by Extracting Clinically Significant Findings from Fused Retinal Imaging Modalities 1, 2, 3, 4 5 Bilal Hassan y , Taimur Hassan y , Bo Li *, Ramsha Ahmed and Omar Hassan 1 School of Automation Science and Electrical Engineering, Beihang University (BUAA), Beijing 100191, China 2 Department of Electrical Engineering, Bahria University (BU), Islamabad 44000, Pakistan 3 School of Computer Science and Engineering, Beihang University (BUAA), Beijing 100191, China 4 School of Computer and Communication Engineering, University of Science & Technology Beijing (USTB), Beijing 100083, China 5 Department of Electrical and Computer Engineering, Sir Syed CASE Institute of Technology (SSCIT), Islamabad 44000, Pakistan * Correspondence: [email protected] These authors contributed equally in this research. y Received: 26 May 2019; Accepted: 26 June 2019; Published: 5 July 2019 Abstract: Macular edema (ME) is a retinal condition in which central vision of a patient is affected. ME leads to accumulation of fluid in the surrounding macular region resulting in a swollen macula. Optical coherence tomography (OCT) and the fundus photography are the two widely used retinal examination techniques that can effectively detect ME. Many researchers have utilized retinal fundus and OCT imaging for detecting ME. However, to the best of our knowledge, no work is found in the literature that fuses the findings from both retinal imaging modalities for the effective and more reliable diagnosis of ME. In this paper, we proposed an automated framework for the classification of ME and healthy eyes using retinal fundus and OCT scans. The proposed framework is based on deep ensemble learning where the input fundus and OCT scans are recognized through the deep convolutional neural network (CNN) and are processed accordingly.
    [Show full text]
  • Research Article OCT Biometry (B-OCT): a New Method for Measuring Ocular Axial Dimensions
    Hindawi Journal of Ophthalmology Volume 2019, Article ID 9192456, 10 pages https://doi.org/10.1155/2019/9192456 Research Article OCT Biometry (B-OCT): A New Method for Measuring Ocular Axial Dimensions Bartosz L. Sikorski 1,2 and Pawel Suchon1,2 1Department of Ophthalmology, Nicolaus Copernicus University, 9 M. Sklodowskiej-Curie St., Bydgoszcz 85-309, Poland 2Oculomedica Eye Center, 9 Broniewskiego St., Bydgoszcz 85-316, Poland Correspondence should be addressed to Bartosz L. Sikorski; [email protected] Academic Editor: Antonio Queiros Copyright © 2019 Bartosz L. Sikorski and Pawel Suchon. Tis is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose. To present a new method of measuring ocular axial dimensions, termed OCT biometry (B-OCT). Design. Observational cross-sectional study and evaluation of new diagnostic technology. Methods. B-OCT was implemented in the spectral domain OCT device for posterior and anterior segment imaging (REVO NX, Optopol Technology). A total of 349 eyes (214 of healthy subjects, 115 of patients with cataract, and 20 with severe macular diseases) were enrolled in the study. Te results of B-OCT were compared to swept source OCT-based IOLMaster 700 (Carl Zeiss Meditec). Diferences in measurement values between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coeffcients (ICCs) and Bland–Altman plots. Results. B-OCT obtained with REVO NX provides excellent interobserver reproducibility (ICC for: axial length (AXL) 1.000; central corneal thickness (CCT) 0.933; anterior chamber depth (ACD) 0.933; lens thickness (LT) ! ! ! ! 0.985) and intraobserver repeatability (ICC for: AXL 1.000; CCT 0.994; ACD 0.998; LT 0.993).
    [Show full text]
  • Retinal Diseases
    Over 260 OCT Images Optical Coherence Tomography in Retinal Diseases A Practical Interactive Book For Technicians And Retinal Clinicians Mariano Cozzi Alessandro Invernizzi Carlo Domenico Bianchi Supervised By: E. Priel - G. Staurenghi COPYRIGHT Mariano Cozzi Alessandro Invernizzi Carlo Domenico Bianchi i Main Authors Mariano Cozzi Alessandro Invernizzi Carlo Domenico Bianchi Contributors Alessandro Pagani Sergio Pagliarini Ethan Priel Supervisor Ethan Priel Giovanni Staurenghi Between flesh and what’s fantasy B. Springsteen ii AUTHORS AFFILIATIONS Mariano Cozzi Orthoptist/Research Ophthalmic Photographer, Eye Clinic, Department of Biomedical and Clinical Sciences "Luigi Sacco" Sacco Hospital, Univer- sity of Milan, Milano, Italy. Alessandro Invernizzi MD Ophthalmologist, medical retina and uveitis service, Eye Clinic, Depart- ment of Biomedical and Clinical Sciences "Luigi Sacco" Sacco Hospital, University of Milan, Milano, Italy. Carlo Domenico Bianchi Orthoptist, Eye Clinic, Department of Biomedical and Clinical Sciences "Luigi Sacco" Sacco Hospital, University of Milan, Milano, Italy. Alessandro Pagani Orthoptist, Eye Clinic, Department of Biomedical and Clinical Sciences "Luigi Sacco" Sacco Hospital, University of Milan, Milano, Italy. Sergio Pagliarini MD Ophthalmologist, Retinal Consultant, The Macular Unit, University Hos- pital Coventry and Warwickshire, Coventry, United Kingdom. Ethan Priel Director / Chief Ophthalmic Photographer, Ophthalmology Department, MOR, Bnei Brak, Israel. Giovanni Staurenghi MD Professor of Ophthalmology,
    [Show full text]
  • Global Next Generation Biomatrics Technology
    e-ISSN (O): 2348-4470 Scientific Journal of Impact Factor (SJIF): 5.71 p-ISSN (P): 2348-6406 International Journal of Advance Engineering and Research Development A National Conference On Spectrum Of Opportunities In Science & Engineering Technology Volume 5, Special Issue 06, April-2018 (UGC Approved) GLOBAL NEXT GENERATION BIOMATRICS TECHNOLOGY Shubham Dhanokar1, Shraddha Shegokar2, Sanket Dhanokar3, Harshada Dhanokar4 1Computer Science And Engineering, STC, SERT , Shegaon 2Computer Science And Engineering, STC, SERT, Shegaon 3Computer Science And Engineering, STC, SERT, Shegaon 4Computer Science And Engineering, STC, SERT, Shegaon Abstract —The global next generation Biometrics Technology market which highlights the latest technological improvements and new launches current industrial affairs and development. This technological system uses information about a person to identify that person. Biometrics verification is any means by which a person can be uniquely identifiers includes fingerprints, hand geometry, earlobe geometry, retina and iris patterns, voice waves, DNA and signatures. The oldest form of Biometrics verification is fingerprinting. Historians have found examples of thumbprints being used as a means of unique identification on clay seals in ancient china. The application of Biometrics technology is include secure access to building, computer system, laptops, cellular phones and ATM’s. Keywords-Fingerprint recognition, iris and retina recognition, voice recognition, face recognition and the latest technologies like behavioral recognition. I. INTRODUCTION Biometrics based solution are able to provide for confidential financial transaction and personal data privacy. The need for biometrics can be found in federal, state and local government in the military and a commercial application. Enterprise- wide network security infrastructure, government ID’s, secure electronic banking, investing and other financial transaction and health and social services are already benefiting from these technologies.
    [Show full text]