Application Notes & Glossary

Total Page:16

File Type:pdf, Size:1020Kb

Application Notes & Glossary Application Notes Application Notes & Glossary& Glossary The Application Notes that follow are a collection of circuits utilizing products found in this catalog. These circuits illustrate possible uses in a variety of applications. It is strongly recommended that you contact our Technical Assistance Team (see below) before using any of this information. Application Notes Alternating & Duplexing Relays Alternating .......................................................................................................................13.3 Duplexing ........................................................................................................................13.3 Duplex Panel with Latching Pump Down Operation .......................................................13.3 Timer Replaces Expensive Float Switch .........................................................................13.4 Operation with Time Delay Installed ................................................................................13.4 Current Sensors Measuring Contamination with a Current Sensor ...........................................................13.5 Using Current Sensing to Detect a Failed Lamp .............................................................13.5 Sensing Failed HID Lighting ............................................................................................13.5 Feed Rate Control Using Sensing ...................................................................................13.6 Using Current Sensors for: Improved Part Counting, Counting Motor Starts, As an Hour Meter Interface ..............13.6 Dull Tool Detection ..........................................................................................................13.7 Load Status Indication - Local and Remote ....................................................................13.7 Sensing Operation of Heat Tapes ....................................................................................13.7 Failed Heater - Fast Visual Indicator Single Phase Heater ..............................................13.8 Three Phase Heater .........................................................................................................13.8 Three Phase Heater Unsupervised Equipment ...............................................................13.9 Multiple Turns to Increase Sensitivity ..............................................................................13.9 The Operation of One Load Starts Another Load Operating Commercial Oven Starts Exhaust Fan ............................................................................13.10 Laundry Dryer Starts Exhaust Fan ..................................................................................13.10 Interlock Two Loads Using Current Sensing ...................................................................13.10 Window Current Sensing for Pump Protection ...............................................................13.11 External Current Transformer ..........................................................................................13.11 HVAC Timers Bypass Timing Allows Low Temperature Starting of an Air Conditioner..................................................13.12 Low Pressure Switch in Compressor Relay Circuit .........................................................13.12 Anti-Short Cycle Anti-Short Cycle and Random Start Protection ..............................................................13.13 Debouncing - Demand Reduction Random Start Sequencing ..............................................................................................13.13 Debouncing - Preventing Contact Chatter ......................................................................13.13 Fan Delays Exhaust Fan Delay ...........................................................................................................13.14 Prepurge ..........................................................................................................................13.14 (Continued on next page) Low Voltage Products & Systems 13.1 ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com 1TRC 001 009 C0202 Index, cont. Application& Glossary Notes Liquid Level Controls Single Probe Control .......................................................................................................13.15 Sensitivity to Ignore Foam ...............................................................................................13.15 Dual Probe Control ..........................................................................................................13.16 Seal Leak Detection ........................................................................................................13.16 Timers Accumulative Timing Accumulative Interval Timing ..........................................................................................13.17 Single Timing Circuits Contact Chatter Elimination ............................................................................................13.17 Compound Timing Functions Sequencing - Independent Adjustment Sequence (Single Cycle) ..................................13.18 Staging (ON and OFF) .....................................................................................................13.18 Dual Momentary Timing (With Lockout) ..........................................................................13.19 Using Proximity and Photoelectric Switches with Timers The Characteristics of Proximity and Photoelectric Switches ........................................13.19 Plug-in Timers .................................................................................................................13.19 Pulse Shaping .................................................................................................................13.19 Solid State Timers ................................................................................................ 13.19, 13.20 Leakage Current (control of) ............................................................................................13.20 Definite Purpose Timing Random Start ..................................................................................................................13.21 Part Winding Start ...........................................................................................................13.21 Thermistor Controlled Timer ............................................................................................13.21 Air Compressor Drain, Automatic Operation ...................................................................13.22 Flow Monitor ....................................................................................................................13.23 Pump Control ..................................................................................................................13.23 Motion Detector Zero Speed Switch ..........................................................................................................13.23 Voltage Monitors Motor Protection Applications Load Side Monitoring ......................................................................................................13.24 Restart Alarm Buzzer/Flasher ..........................................................................................13.24 Delayed Restart ...............................................................................................................13.24 Restart Bypass Delay ......................................................................................................13.25 Compressor Anti-Short Cycle Lockout Delay .................................................................13.25 Protection & Control Understanding Voltage Faults - Voltage Unbalance ........................................................13.26 Calculating Percent Overheating .....................................................................................13.26 Three Phase Voltage Monitor Universal Voltage Monitor Controls Switching of a Transfer Panel .................................13.27 Universal Voltage Monitor in a Motor Starter ..................................................................13.27 Glossary of Terms Glossary .............................................................................................................................13.28 13.2 Low Voltage Products & Systems 1TRC 001 009 C0202 ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com Application Notes Alternating & Duplexing Relays & Glossary Application Notes Alternating: Power must be applied at all times. When the level Duplexing: When an Alternating Relay is internally cross wired, in the tank rises to the normal level, the Lead Float Switch closes. the normal alternating operation is extended to include duplexing. Pump “A” is turned on via Pump “A” contactor, and will remain in If the Lead Float Switch cycles as previously explained, normal this condition until the Lead Float Switch opens. When the Lead alternating operation will occur. If the Lead Float Switch and Float Switch opens, the ARP relay contacts transfer. When the level the Lag Float Switch close simultaneously, due to a heavy flow in the tank rises again to the normal level, the Lead Float Switch into the tank, both pumps A & B will be energized. The ability to closes, energizing Pump “B” via Pump “B” contactor. Pump “B” alternate the pumps during normal work loads and then operate will remain energized until the Lead Float Switch opens. The ARP both when the
Recommended publications
  • List of Spare Part2 March2020.Xlsx
    Spares Parts List for HDD Operations # WD item code Item Description Part # Item Group PN1 Quantity PN2 Quantity 1 1010005 Fiber Optic Sensor FR505 Sensor 0 11 2 1010006 Fiber Optic Sensor FR5FC Sensor 0 25 3 1010009 Fiber Optic Sensor FT505 Sensor 0 18 4 1010013 Fiber Optic Amplifier F5N Sensor 0 36 5 1010015 Hall Effect Position Sensor RP1 Sensor #N/A 7 6 1010016 Hall Effect Position Sensor RP2 Sensor 0 7 7 1010018 Photoelectric Switch E32-CC200 Sensor 0 5 8 1010019 Fiber Optic Sensor E32-D33 Sensor 0 13 9 1010021 Proximity Sensor GTR1SN Sensor 0 20 10 1010026 Proximity Switch CS9HA Sensor 0 45 11 1010036 Proximity Switch OPB 830W55 Sensor #N/A 7 12 1010037 Proximity Switch D-A53 Sensor 0 22 13 1010038 Proximity Switch GL-12F Sensor 0 12 14 1010043 Proximity Sensor PM-T53 Sensor 0 19 15 1010061 Photoelectric Switch E3JK-DS30M2 Sensor #N/A 17 16 1010063 Photoelectric Switch E3R-5DE4 Sensor #N/A 29 17 1010076 Proximity Switch RS 105L 90/8 Sensor #N/A 13 18 1010077 Proximity Switch RS 105L Sensor 0 38 19 1010080 Proximity Switch 650800-030 Sensor #N/A 10 20 1010087 Proximity Switch CS11TA Sensor #N/A 23 21 1010089 Proximity Switch CS4HA Sensor #N/A 28 22 1010093 Proximity Switch D-H7BA Sensor 0 37 23 1010099 Sensor Amplifier E3X-A11 Sensor 0 10 24 1010103 Proximity Sensor GTL1SN Sensor 0 20 25 1010113 Photoelectric Switch E3S-BD61 Sensor 0 7 26 1010117 Proximity Switch EE-SPY412 Sensor 0 100 27 1010118 Proximity Switch EE-SV3 Sensor 0 28 28 1010119 Proximity Switch EE-SY671 Sensor 0 45 29 1010121 Proximity Switch OPB 665T Sensor #N/A 18
    [Show full text]
  • Aurora Water Piney Creek Lift Station Improvements
    W DRAWINGS FOR W W W W W W W W AURORA WATER W W BE W BE W BE W BE W BE W LIFT W STATION PINEY CREEK BE W GENERATOR W BE W LIFT STATION W W W W W BE W IMPROVEMENTS 22464 EAST OTTAWA DRIVE AURORA, COLORADO 80016 AURORA PROJECT NO. 5167A GUN E-470 B&V PROJECT NO. 162731 CLUB ROAD SMOKEY HILL ROAD SMOKEY HILL ROAD SADDLE ROCK NORTH R E-470 STRATEGIC EASEMENTS 45.00' (7.84 AC.) REALTY PROPERTIES PONDEROSA (E-470) TRAIL Denver, Colorado ARAPAHOE SADDLE ROCK LIFT EAST TALLYN'S REACH NORTH SADDLE ROCK SOUTH STATION 2008 SITE CARMA ROAD Approved for One Year From This Date O REG D I S A T R M E . R O T U R N S L E K E R O D T C 41112 P E-470 R R E O E F Aurora City Engineer Date N E I S S G I EN ONA L LOCATION MAP Aurora Water Department Date SCALE: 1"=1000' APP CK AREA DESIGNATIONS BY ONE-LINE DIAGRAM LEGEND SCHEMATIC SYMBOLS ABBREVIATIONS THE SPECIAL AREA DESIGNATION BOXES, AS DEFINED BELOW, ARE LOCATED ON THE PLAN DRAWINGS TO DEFINE ELECTRICAL INSTALLATION REQUIREMENTS. NO. A AMBER, AMPERE, ALARM M MAGNETIC MOTOR STARTER DESIGNATION BOXES ARE LOCATED WITHIN ROOM OR BELOW ROOM NUMBER. ALL TRANSFORMER WITH PRIMARY AND SECONDARY WIRE CONNECTION POINT PRESSURE SWITCH AC ALTERNATING CURRENT MA MILLIAMPERE INDOOR AREAS NOT INDICATED OTHERWISE ARE AREA TYPE 1 AND MINIMUM VOLTAGE, AND KVA RATING AS NOTED P (OPENING ON RISING PRESSURE) ACB AIR CIRCUIT BREAKER MCB MAIN CIRCUIT BREAKER EXTERNAL CONNECTION POINT AF AMPERE FRAME MCC MOTOR CONTROL CENTER NEMA TYPE 1 ENCLOSURES.
    [Show full text]
  • Design and Prototyping of an Antenna-Coupled Cryotron
    Portland State University PDXScholar Dissertations and Theses Dissertations and Theses Spring 5-16-2014 Design and Prototyping of an Antenna-Coupled Cryotron Shauna Jensen Portland State University Follow this and additional works at: https://pdxscholar.library.pdx.edu/open_access_etds Part of the Power and Energy Commons Let us know how access to this document benefits ou.y Recommended Citation Jensen, Shauna, "Design and Prototyping of an Antenna-Coupled Cryotron" (2014). Dissertations and Theses. Paper 1788. https://doi.org/10.15760/etd.1787 This Thesis is brought to you for free and open access. It has been accepted for inclusion in Dissertations and Theses by an authorized administrator of PDXScholar. Please contact us if we can make this document more accessible: [email protected]. Design and Prototyping of an Antenna-Coupled Cryotron by Shauna Marie Jensen A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Electrical and Computer Engineering Thesis Committee: Robert Bass, Chair Richard Campbell Branimir Pejcinovic Portland State University 2014 © 2014 Shauna Marie Jensen Abstract Grid-scale integration of renewable energy sources and smart grid devices has created new demands in flexible power conversion. State-of-the-art semiconductor power switches present limitations in power handling capability, as well as forward and reverse breakdown voltages. Superconducting materials are a viable alternative due to their robustness against high ampacities, large electric fields and abrupt changes in power flow. This work pays focus to material testing and apparatus design for an antenna-coupled cryotron (ACC), which is a superconducting power switch. Design, fabrication and testing are examined for a longitudinal resonant cavity, paired with monopole transmit and modified slot receive antennae.
    [Show full text]
  • Mixer 80/100/120 Cubic Foot
    MIXER 80/100/120 CUBIC FOOT MAINTENANCE/OPERATION CATALOG 466363F9902 JULY 1999 • US$250 World Headquarters 801 Johnson St. • Alpena, Michigan, 49707 • U.S.A. Phone (517) 354-4111 COMPANY NAME: .............................................................. SERIAL NUMBER: .............................................................. ASSEMBLY NUMBER: .............................................................. WIRING DIAGRAM NUMBER: .............................................................. INSTALLATION DRAWING NUMBER: ............................................................ Table of Contents 80/100/120 Cubic Foot 80/100/120 CUBIC FOOT TABLE OF CONTENTS LIST OF FIGURES . .v LIST OF TABLES . .vi NOTICE . .vi MIXER SPECIFICATIONS . .vii PRIMARY MIXER DIMENSIONS . .viii MIXER ELECTRICAL DATA . .ix 80 Cubic Foot . .x 100 Cubic Foot . .xii 120 Cubic Foot . .xiv SAFETY BULLETIN . .xvi SAFETY SIGNS . .xvii LIFTING POINTS . .xxi DECALS . .xxii SECTION 1 MIXER OVERVIEW 1.1 INFORMATION ABOUT THIS MANUAL . .1-1 1.2 ORGANIZATION OF THIS GUIDE . .1-1 1.3 TERMS AND ABBREVIATIONS . .1-1 1.4 SAFETY INFORMATION . .1-2 1.4.1 General Lockout for all Batching Controls . .1-2 1.4.2 Lockout and Tag Equipment which Presents a Hazard to Personnel Working on the Mixer . .1-2 1.4.3 Lockout and Tag Mixer . .1-2 1.5 DESCRIPTION OF MAJOR COMPONENTS . .1-3 1.5.1 Air-Operated Discharge Gate . .1-4 1.5.2 Circuit for Switching Contact Protection (Inductive Loads) . .1-6 1.5.3 Drive Shaft with Clutch* . .1-7 1.5.4 Gear Guard . .1-8 1.5.5 Pulley Guard . .1-8 1.5.6 Removable Head Section . .1-9 1.5.7 Enclosed Drum . .1-9 1.5.8 Cleaning Rings* . .1-9 1.5.9 Head Scrapers* . .1-9 1.5.10 Blade Shaft Covers* .
    [Show full text]
  • RED LASER MODULES Plastic Nuts and Rubber O-Ring
    LIQUID SENSORS THROUGH-BEAM PHOTO- ELECTRIC SENSOR PAIR FLUID PRESSURE SENSOR Using a 5 Vdc input, the fluid SICK Optics WS15-D1130 / WE15-A1130. pressure sensor provides a Photo-electric sender and receiver 0.25 - 4 Vdc output proportional pair detects the presence to pressure from 0-5" H2O max. of an object when the Typical applications include beam between the two is duct air flow, filter pressure interrupted. When the monitoring, combustion air flow and gaseous beam is broken, the leak detection. Measures 1-5/16" x 17/32" on a receiver produces a current pair of 7/8" long slotted mounting wings. Two that can be used to trigger 3/16" O.D. barbs. 3-pin connector with 3" wire an audio-visual signal or leads for power and output. relay-operated device. CAT # FLS-4 $3.15 each 5 Meter range. Built-in LED alignment and power indicators. Modules are 38 x 21 x LIQUID LEVEL SENSOR 16.2mm and can be front or side-mounted. Float switch closes circuit when float Front-mount hardware is included. Operate on rises to top of switch (end opposite 10-30Vdc. Power supply not included. cULus. leads). Can be used in opposite CAT # OSU-1130 $11.35 pair direction as well to close circuit when water level drops. 0.96" diameter plastic float and 0.35" threaded bushing with RED LASER MODULES plastic nuts and rubber O-ring. 2.64" overall length. 14" pigtail leads. Class IIIA lasers, ≤5mW CAT # FLW-2 $3.35 each Wavelegth: 650mM, red 3-5Vdc operation, < 40mA FLOAT SWITCH WITH INTEGRATED THERMISTOR LASER DIODE Gems Sensors.
    [Show full text]
  • Chapter 7 TIMERS, COUNTERS and T/C APPLICATIONS
    Chapter 7 TIMERS, COUNTERS and T/C APPLICATIONS Introduction Timers and counters are discussed in the same chapter since most rules apply to both. Timers and counters have been in existence for as long as relays and provide an important component in the development of logic. Timers were constructed in the past as an add-on device to relays slowing down the transition of the plunger from immediately opening or closing. The time delay was accomplished with a pneumatic bladder that allowed the air to escape either quickly or slowly depending on the setting of the timer. Quick was usually less than a second and slow was usually between 30 and 60 seconds. Setting this kind of timer was an inexact science and today's traffic lights are an example of the fickle nature of timers that seldom respond in exactly the same from day to day and year to year. For the first time, function blocks are introduced in the rung output position or coil position to provide timer and counter functions. Function blocks allow inputs from the left and pass power through to the right when the function is done or when various conditions are met. Either the timer has timed out or the counter has counted to the preset. Function block usage differs from manufacturer to manufacturer. Function blocks rely on a standard format to enter information about the counter or timer. All variables in the function block must be entered correctly before the device will operate. Some timers are referred to as retentive. Retentive refers to the device’s ability to remember its exact status such that when the circuit is again activated, the timer continues from the previous point.
    [Show full text]
  • Float Type Level Switches Contents Page Start Single Point Small Size Engineered Plastic
    INTRODUCTION Float Type Level Switches Contents Page Start Single Point Small Size Engineered Plastic ........................................... A-2 GEMS Level Switches operate on a direct, Alloy ........................................................................ A-8 simple principle. In most models, a float encircling a stationary stem is equipped Large Size PERMANENT with powerful, permanent magnets. As MAGNET Engineered Plastic .........................................A-12 the float rises or lowers with liquid level, Alloy ......................................................................A-13 the magnetic field generated from within FLOAT the float actuates a hermetically sealed, Specialty Switches ...............................................A-20 magnetic reed switch mounted within the HERMETICALLY stem. The stem is made of non-magnetic SEALED MAGNETIC REED SWITCH Leak Detection .......................................................A-22 metals or rugged, engineered plastics. When mounted vertically, this basic design provides a consistent accuracy of ±1/8 inch. Multi-station versions use a separate reed switch for each level point being monitored. Side-mounted units use different actuation methods because of their horizontal attitude. The basic principle, however, is the same: as a direct result of rising or falling liquid, a magnetic field is moved into the proximity of a reed switch, causing its actuation. N Reed Switch Reliability – SINGLE POINT LEVEL SWITCHES GLASS The durable construction of these reed switch designs ensures long, trouble- REED SWITCH ENVELOPE free service. Because the effects of shock, wear and vibration are minimized, these hermetically sealed switches provide precise S repeatability with no more than 1% deviation. The switch actuation points N S remain constant over the life of the unit. See “Reed Switch Protection” in MAGNET Appendix X for information on extending the life of GEMS Level Switches.
    [Show full text]
  • FM2819 Catalog, Accessories, Controls, and Package Systems
    Package Systems, Controls, and Accessories Package Systems Check Valves Float Switches Alarm Systems Control Panels Rail Systems ® WHAT SETS ZOELLER SYSTEMS APART? Since 1939, Zoeller Company has been manufacturing water pumps of many types. From pedestal pumps in the beginning to large HP submersible, non-clog pumps in recent years, we have gained invaluable manufacturing experience from our humble beginning in August Zoeller’s basement workshop. Over the years, one of our most important mottos has been, ‘We excel at 1,000 little things’. From start to finish, we take pride in our products. When you have residential or commercial wastewater issues, you can count on Zoeller to deliver the very best solutions. Our commitment to unsurpassed quality offers years of service and durability with a responsive and knowledgeable product support team just a phone call away. • SUPPORTING THE WHOLE PACKAGE… In pumping systems, the “whole package” encompasses far more than just high quality pumps. The control, alarm, valves, disconnects, piping and container are all important components of a complete system. Zoeller understands that an installation is only as good as the weakest element, so we have gone to great lengths to provide accessory items that are as reliable as our legendary pumps. While we manufacture most of our products from start to finish, including check valves and rail systems, we recognize that producing certain specialized accessories requires a different skill set than our roots provide. In order to offer you the best components for your project, we have partnered with other specialized manufacturers, all of them leaders in their respective fields.
    [Show full text]
  • The Ultimate Guide to Float Level Sensors
    The Ultimate Guide to Float Level Sensors Electrical Connection Electrical Connection Fitting with threadsA HIGHER down LEVEL OF SATISFACTION Threads up L3 Float L2 Float Stop L1 OAL Electrical Connection Electrical Connection Fitting with threads down Threads up L1 OAL Float Float Stop Table of Contents Introduction .................................................................................................................................................. 5 Overview of level sensors, their use and selection ............................................................................. 6 The float switch level sensor ................................................................................................................. 7 The continuous level sensor .................................................................................................................. 7 Magnetic float switch reliability ............................................................................................................ 7 Examples of level sensor use and applications ....................................................................................... 8 Oil/water separators ............................................................................................................................... 8 Food processing equipment .................................................................................................................. 8 Biotech....................................................................................................................................................
    [Show full text]
  • CITY of NORTH MIAMI Public Works Department Rehabilitation of Pump Station “A” Bid Set Contract IFB No. 55-20-21
    CITY OF NORTH MIAMI Public Works Department Rehabilitation of Pump Station “A” Bid Set Contract IFB No. 55-20-21 City of North Miami Public Works Department 776 NE 125th Street – 3rd Floor North Miami, Florida 33161 Prepared By: 800 Douglas Entrance Suite 200 Coral Gables, Florida 33134 Phone: (305) 718-4828 Date: June 2020 TABLE OF CONTENTS DIVISION 0 - BIDDING AND CONTRACT REQUIREMENTS TBD Notice to Bidders TBD Instructions to Bidders TBD Cone of Silence 00300 Proposal 00301 Proposal Bid Form TBD Approved Bid Bond 00495 Trench Safety Form TBD Contract TBD Performance Bond TBD Payment Bond TBD General Conditions TBD Supplementary General Conditions DIVISION 1 - GENERAL REQUIREMENTS 01010 Summary of Work 01015 Index of Drawings 01025 Measurement and Payment 01080 Abbreviations and Definitions 01090 Reference Standards 01110 Environmental Protection Procedures 01200 Project Meetings 01300 Submittals 01310 Construction Progress Schedules 01380 Construction Photographs 01400 Quality Assurance 01410 Contractor Health and Safety Plan 01500 Temporary Facilities 01530 Protection of Existing Facilities 01568 Erosion Control, Sedimentation and Containment of Construction Materials 01600 Control of Materials 01610 Delivery, Storage and Handling 01700 Contract Closeout 01710 Cleaning Up 01740 Warranties and Bonds DIVISION 2 - SITE WORK 02013 Connections to Existing Buried Pipelines 02050 Demolition and Alterations 02100 Site Preparation City of North Miami Pump Station “A” Rehab – 100% Submittal 00015-i Bid Set TABLE OF CONTENTS (Cont.) 02140 Dewatering
    [Show full text]
  • Field Devices for Process Automation
    PROCESS AUTOMATION FIELD DEVICES FOR PROCESS AUTOMATION With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the "Elektrotechnik und Elektroindustrie (ZVEI) e.V." including the supplementary clause: "Extended reservation of title". We at Pepperl+Fuchs recognise a duty to make a contribution to the future. For this reason, this printed matter is produced on paper bleached without the use of chlorine. THE SUCESS STORY OF PEPPERL+FUCHS 1945 Walter Pepperl and Ludwig Fuchs lay the foundation of Pepperl+Fuchs: The opening of a radio repair shop 1948 Manufacture of transformers 1958 Development and production of the first inductive proximity switch 1973 The first foreign subsidiary is formed in England 1979 Pepperl+Fuchs commences production in Singapore 1988 Michael Fuchs and Claus Michael take over the management of the company and Pepperl+Fuchs becomes a limited liability company 1991 Split into Factory Automation and Process Automation divisions, new product group level control through a company acquisition 1996 The purchase of another company establishes the encoder business 1997 New production facilities open at Veszprem/Hungary 2000 Expansion of the Factory Automation activities with the purchase of Visolux GmbH and the Microswitch and Photoswitch interests from Honeywell; at the same time the Process Automation sector is expanded by the takeover of ELCON 2000 Start of
    [Show full text]
  • Electrical Blasting Cap
    electrical blasting cap electrical blasting cap [ENG] A blasting cap ig- electrical prospecting [ENG] The use of down- nited by electric current and not by a spark. hole electrical logs to obtain subsurface informa- { əlekиtrəиkəl blastиiŋkap } tion for geological analysis. { ilekиtrəиkəl pra¨s electrical breakdown See breakdown. { əlekиtrəи pekиtiŋ } kəl bra¯kdau˙ n} electrical resistance See resistance. { ilekиtrəиkəl electrical conductance See conductance. { əlekи rizisиtəns } trəиkəlkəndəkиtəns } electrical-resistance meter See resistance meter. electrical conduction See conduction. { əlekиtrəи {ilekиtrəиkəlrizisиtəns me¯dиər} kəlkəndəkиshən} electrical-resistance strain gage [ENG] A vibra- electrical conductivity See conductivity. { əlekи tion-measuring device consisting of a grid of fine trəиkəl ka¨ndəktivиədиe¯ } wire cemented to the vibrating object to measure electrical drainage [ELEC] Diversion of electric fluctuating strains. { ilekиtrəиkəlrizisиtəns currents from subterranean pipes to prevent stra¯n ga¯j} electrolytic corrosion. { ilekиtrəиkəl dra¯nиij } electrical-resistance thermometer See resistance electrical engineer [ENG] An engineer whose thermometer. { ilekиtrəиkəlrizisиtəns thər training includes a degree in electrical engi- ma¨mиədиər} neering from an accredited college or university electrical resistivity [ELEC] The electrical (or who has comparable knowledge and experi- resistance offered by a material to the flow of ence), to prepare him or her for dealing with current, times the cross-sectional area of current the generation, transmission, and utilization of flow and per unit length of current path; the electric energy. { ilekиtrəиkəl enиjənir } reciprocal of the conductivity. Also known as electrical engineering [ENG] Engineering that resistivity; specific resistance. { ilekиtrəиkəl re¯и deals with practical applications involving cur- zistivиədиe¯ } rent flow through conductors, as in motors and electrical resistor See resistor.
    [Show full text]