An Open Source and Low Cost Pulsed-Field Gel Electrophoresis Equipment

Total Page:16

File Type:pdf, Size:1020Kb

An Open Source and Low Cost Pulsed-Field Gel Electrophoresis Equipment bioRxiv preprint doi: https://doi.org/10.1101/2020.06.22.165928; this version posted June 23, 2020. The copyright holder for this preprint (which was not certified by peer review) is the author/funder, who has granted bioRxiv a license to display the preprint in perpetuity. It is made available under aCC-BY 4.0 International license. Title: openPFGE: An open source and low cost pulsed-field gel electrophoresis equipment Authors: Diego Lagos-Susaetaa, Oriana Salazara, Juan A. Asenjoa Affiliations: aCentre for Biotechnology and Bioengineering, Department of Chemical Engineering, Biotechnology and Materials, University of Chile, Santiago, Chile Contact email: [email protected] Abstract: DNA electrophoresis is a fundamental technique in molecular biology that allows the separation of DNA molecules up to ~50 Kbp. Pulsed-field gel electrophoresis [PFGE] is a variation of the conventional DNA electrophoresis technique that allows the separation of very large DNA molecules up to ~10 Mbp. PFGE equipment is very expensive and it becomes an access barrier to many laboratories. Also, just a few privative designs of the equipment are available and it becomes difficult for the community to improve or customize their functioning. Here, we provide an open source PFGE equipment capable of the separation of DNA molecules up to, at least, ~2 Mbp and at low cost: USD$850, about 3% of the price of typical commercial equipment. Keywords: Biotechnology, Molecular biology, DNA Electrophoresis, Low cost equipment, Open source equipment, Pulsed-Field Gel Electrophoresis [PFGE] Specifications table Hardware name openPFGE Subject area Chemistry and Biochemistry Hardware type Biological sample handling and preparation Open Source License Hardware: CERN Software: GPL Documentation: CC BY Cost of Hardware $850 Source File Repository Current development version at https://doi.org/10.5281/ zenodo.3727331. Older and newer versions at https://gitlab.com/diegusleik/openpfge bioRxiv preprint doi: https://doi.org/10.1101/2020.06.22.165928; this version posted June 23, 2020. The copyright holder for this preprint (which was not certified by peer review) is the author/funder, who has granted bioRxiv a license to display the preprint in perpetuity. It is made available under aCC-BY 4.0 International license. 1.Hardware in context DNA electrophoresis is a frequently used technique in molecular biology that allows the separation of DNA molecules up to ~50 Kbp by applying a single-direction electric field across a slab of agarose gel where small DNA molecules are sieved in a size-dependent manner. However, the sieving effect underlying such separations fails when very large DNA molecules must be resolved, as is the case of genomic analysis using intact chromosomal DNA molecules or analysis and manipulation of very large restriction fragments. Pulsed-field gel electrophoresis [PFGE], developed by Schwartz and Cantor (1), is a variation of the conventional DNA electrophoresis technique that allows the separation of very large DNA molecules up to ~10 Mbp. This is achieved by a periodic and abrupt change in the direction of the electric field that exploits the reptation phenomena of large DNA molecules to allow size- dependent electrophoretic mobility. Bacterial subtyping is the main PFGE application due to the discriminatory power, simplicity and low cost of the technique. Although some laboratories are transitioning towards whole genome sequencing-based typing, it remains important for small hospitals and laboratories with limited resources and it will be the more feasible option for bacterial subtyping by longer (2)(3). This technology plays a key role in modern genomics, as it allows manipulations with DNA of whole chromosomes or their large fragments (4) as is the case, for example, of Cas9- assisted targeting of chromosome segments [CATCH] (5) or DNA fragment size assessment for Next-Gen Sequencing (6). Biochemistry is an area where highly sophisticated equipment is required. In general, few equipment - i.e. PCR thermocyclers (7) - have an open source version, limiting the development of improved/custom equipment, and the costs of such equipment tended to be very high, which imposes a high barrier for democratizing its usage in many academic labs. PFGE equipment is expensive and exclusively sold by two providers [Bio Rad, Analytik Jena], they cost around USD$30,000 and do not have an open source version. Commercial PFGE equipment control of the electric field reorientation are based on both electronic circuitry [CHEF, Bio Rad] and physical rotating electrodes [Rotaphor, Analytik Jena]. Open hardware and free and open source software [FOSS] provides tools for fabricating devices at lower costs and higher adaptability. Easy to use microcontrollers such as Arduino and manufacturing technologies such as 3D printers has enabled a diverse community of developers to start building new customized, low cost and open source devices. bioRxiv preprint doi: https://doi.org/10.1101/2020.06.22.165928; this version posted June 23, 2020. The copyright holder for this preprint (which was not certified by peer review) is the author/funder, who has granted bioRxiv a license to display the preprint in perpetuity. It is made available under aCC-BY 4.0 International license. 2.Hardware description Hardware and circuit design and construction General outline Here we describe openPFGE, an open source and low cost PFGE equipment. The equipment implements a rotating gel electrophoresis [RGE] over an uniform electric field [Figure 1 & 2], using the basis of the system described by Southern in 1987 (8).The design considers the use of a standard commercially available electrophoresis chamber and the construction of an agarose gel rotation system using 3D printed parts, a servo motor and simple electronics. It incorporates a custom cooling system using a small pump and peltier cooler elements. The control of the motor, the cooling system and the parameters of the run are made via bluetooth communication to a smartphone running an Android app. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Peltier Fan Buffer element exchange Electrode 0 - 180° Water Heat Peristaltic block sink pump Buffer cooling unit Servo motor Circuit agarose gel ● Controls cooling unit reorientation ● Controls servo motor Circuit ● Parameters and control over Fixed electric field Bluetooth ● LCD run parameters LCD Electrode + + + + + + + + + + + + + Electrophoresis chamber High voltage 12 [V] power source power source Fig 1. openPFGE equipment diagram. Main components of openPFGE hardware: A servo motor reorient the agarose gel position by rotating a gel tray in respect to a fixed electric field. Movement of the servo motor is controlled by a circuit whose parameters are determined via Bluetooth by an Android app. Circuit also controls a buffer cooling unit.*. *Some icons made by Freepick, Google, Eucalyp and Those Icons from www.flaticon.com. bioRxiv preprint doi: https://doi.org/10.1101/2020.06.22.165928; this version posted June 23, 2020. The copyright holder for this preprint (which was not certified by peer review) is the author/funder, who has granted bioRxiv a license to display the preprint in perpetuity. It is made available under aCC-BY 4.0 International license. Electrophoresis chamber Peltier cooling system Peristaltic pump Circuit Servo motor Gel tray LCD High voltage power source 12 [V] power source Fig 2. openPFGE equipment picture. General view of the RGE system implemented, highlighting its main components. RGE system In a RGE, the electrodes of the electrophoresis chamber remains fixed while the agarose gel is rotated to achieve the reorientation of the direction of the electric field across the gel. As the servo motor that performs the movement of the agarose gel in this implementation operates in 180° angle, the position of the gel in respect to the electric field can be specified at any time of the run in a -90° / +90° position. A zig-zag pattern in the direction of the electric field is applied to obtain a net straight migration of DNA molecules [Figure 3]. bioRxiv preprint doi: https://doi.org/10.1101/2020.06.22.165928; this version posted June 23, 2020. The copyright holder for this preprint (which was not certified by peer review) is the author/funder, who has granted bioRxiv a license to display the preprint in perpetuity. It is made available under aCC-BY 4.0 International license. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Electrode 0 - 180° Servo motor agarose gel reorientation [Left] Pulsed periodic reorientation of DNA Fixed electric field [Right] Net DNA migration Electrode + + + + + + + + + + + + + Fig 3. Electric field reorientation in RGE. Diagram shows [Left] the static electric field provided by the electrophoresis chamber electrodes and how the rotation of the gel by the servo motor alters the orientation of the electric field through the agarose gel and [Right] a zig-zag pattern in the direction of the electric field is applied to obtain a net straight migration of DNA molecules In order to keep the design simple and the cost as low as possible, a gel rotating system inside a standard large electrophoresis chamber was implemented in this design. In this case, a 310 x 150 x 90 [mm] chamber and a 100 x 60 [mm] agarose gel is proposed, but it can be adapted to any chamber/gel size. This gel rotating system incorporates simple 3D printed parts composed of: 1) a tray base, that supports the gel; 2) a tray cover, that fixes the gel position; 3) a stem, that goes from the tray cover through the electrophoresis chamber cover and joins the servo motor; and, 4) a joint, of the stem to the servo motor that allows easy release of the tray using a strong magnetic couple. It also includes a 180 degrees, 5 [V], high speed and accuracy digital servo motor - like the DS3218-MG - that allows the PFGE to move at any specified angle. All 3D printed parts were designed considering the Fused Deposition Modeling [FDM] process by using mostly horizontal and vertical faces, low inclination angles and no - or really small - ceilings, therefore, no support structures are needed.
Recommended publications
  • Agarose Gel Electrophoresis
    Laboratory for Environmental Pathogen Research Department of Environmental Sciences University of Toledo Agarose gel electrophoresis Background information Agarose gel electrophoresis of DNA is used to determine the presence and distinguish the type of nucleic acids obtained after extraction and to analyze restriction digestion products. Desired DNA fragments can be physically isolated for various purposes such as sequencing, probe preparation, or for cloning fragments into other vectors. Both agarose and polyacrylamide gels are used for DNA analysis. Agarose gels are usually run to size larger fragments (greater than 200 bp) and polyacrylamide gels are run to size fragments less than 200 bp. Typically agarose gels are used for most purposes and polyacrylamide gels are used when small fragments, such as digests of 16S rRNA genes, are being distinguished. There are also specialty agaroses made by FMC (e.g., Metaphor) for separating small fragments. Regular agarose gels may range in concentration from 0.6 to 3.0%. Pouring gels at less or greater than these percentages presents handling problems (e.g., 0.4% agarose for genomic DNA partial digests requires a layer of supporting 0.8% gel). For normal samples make agarose gels at 0.7%. The chart below illustrates the optimal concentrations for fragment size separation. The values listed are approximate and can vary depending on the reference that is used. If you do not know your fragment sizes then the best approach is to start with a 0.7% gel and change subsequently if the desired separation is not achieved. Nucleic acids must be stained prior to visualization. Most laboratories use ethidium bromide but other stains (e.g., SYBR green, GelStar) are available.
    [Show full text]
  • Microchip Electrophoresis
    Entry Microchip Electrophoresis Sammer-ul Hassan Mechanical Engineering, University of Southampton, Southampton SO17 1BJ, UK; [email protected] Definition: Microchip electrophoresis (MCE) is a miniaturized form of capillary electrophoresis. Electrophoresis is a common technique to separate macromolecules such as nucleic acids (DNA, RNA) and proteins. This technique has become a routine method for DNA size fragmenting and separating protein mixtures in most laboratories around the world. The application of higher voltages in MCE achieves faster and efficient electrophoretic separations. Keywords: electrophoresis; microchip electrophoresis; microfluidics; microfabrications 1. Introduction Electrophoresis is an analytical technique that has been applied to resolve complex mixtures containing DNA, proteins, and other chemical or biological species. Since its discovery in the 1930s by Arne [1], traditional slab gel electrophoresis (SGE) has been widely used until today. Meanwhile, new separation techniques based on electrophoresis continue to be developed in the 21st century, especially in life sciences. Capillary electrophoresis (CE) provides a higher resolution of the separated analytes and allows the automation of the operation. Thus, it has been widely used to characterize proteins and peptides [2], biopharmaceutical drugs [3], nucleic acids [4], and the genome [5]. The development of microfabrication techniques has led to the further miniaturization of electrophoresis known Citation: Hassan, S.-u. Microchip as microchip electrophoresis (MCE). MCE offers many advantages over conventional Electrophoresis. Encyclopedia 2021, 1, capillary electrophoresis techniques such as the integration of different separation functions 30–41. https://dx.doi.org/10.3390/ onto the chip, the consumption of small amounts of sample and reagents, faster analyses encyclopedia1010006 and efficient separations [6,7].
    [Show full text]
  • QPNC-PAGE Standardized Protocol for Acidic, Basic and Neutral Metalloproteins MW 6 - > 200Kda USE ONLY FRESH GELS
    QPNC-PAGE Standardized Protocol For Acidic, Basic and Neutral Metalloproteins MW 6 - > 200kDa USE ONLY FRESH GELS Correspondence: Bernd Kastenholz • Research Centre Juelich • Institute of Chemistry and Dynamics of the Geosphere – Phytosphere (ICG-3) • Juelich 52425 • Germany • E-mail: [email protected] Recommended Tools (Bio-Rad) Model 491 Prep Cell (U.S. patent no. 4,877,510) Power Pac 1000: Constant Power: 5 W; Time: 8 hr Model EP-1 Econo Pump: 1 mL/min; 5 mL/fraction; 80 mL prerun V; 480 ml total V (Eluent) Model 2110 Fraction Collector: 80 Fractions Model EM-1 Econo UV Monitor: AUFS 1.0; Detection Wavelength 254 nm Model 1327 Econo Recorder: Range: 100 mV; Chart Speed: 6 cm/hr Model SV-3 Diverter Ventil Buffer Recirculation Pump: Flow Rate: 95 mL/min (Electrophoresis Buffer) Stock Solutions 1) 200 mM Tris-HCl 10 mM NaN3 pH 10.00 – Keep RT. 2) 200 mM Tris-HCl 10 mM NaN3 pH 8.00 – Keep RT. 3) 40 % Acrylamide/Bis 2.67 % C - Keep 4°C. 4) 10 % Ammonium Persulfate (APS) - Keep 4°C (freshly prepared). Electrophoresis Buffer 20 mM Tris-HCL 1 mM NaN3 pH 10.00 degassed – Keep 4°C Upper Electrophoresis Chamber (Prep Cell): 500 mL Electrophoresis Buffer Lower Electrophoresis Chamber (Prep Cell): 2000 mL Electrophoresis Buffer Eluent 20 mM Tris-HCL 1 mM NaN3 pH 8.00 degassed – Keep 4°C Elution Chamber (Prep Cell): 700 mL Elution Buffer Separating Gel Acrylamide 4% T Volume: 40 mL ingredients: 4 mL 40 % Acrylamide/Bis 2.67 % C 4 mL 200 mM Tris-HCl 10 mM NaN3 pH 10.00 32 mL H2O 200 µL 10% APS 20 µL TEMED Add TEMED and APS at the end.
    [Show full text]
  • Protein Blotting Guide
    Electrophoresis and Blotting Protein Blotting Guide BEGIN Protein Blotting Guide Theory and Products Part 1 Theory and Products 5 Chapter 5 Detection and Imaging 29 Total Protein Detection 31 Transfer Buffer Formulations 58 5 Chapter 1 Overview of Protein Blotting Anionic Dyes 31 Towbin Buffer 58 Towbin Buffer with SDS 58 Transfer 6 Fluorescent Protein Stains 31 Stain-Free Technology 32 Bjerrum Schafer-Nielsen Buffer 58 Detection 6 Colloidal Gold 32 Bjerrum Schafer-Nielsen Buffer with SDS 58 CAPS Buffer 58 General Considerations and Workflow 6 Immunodetection 32 Dunn Carbonate Buffer 58 Immunodetection Workflow 33 0.7% Acetic Acid 58 Chapter 2 Methods and Instrumentation 9 Blocking 33 Protein Blotting Methods 10 Antibody Incubations 33 Detection Buffer Formulations 58 Electrophoretic Transfer 10 Washes 33 General Detection Buffers 58 Tank Blotting 10 Antibody Selection and Dilution 34 Total Protein Staining Buffers and Solutions 59 Semi-Dry Blotting 11 Primary Antibodies 34 Substrate Buffers and Solutions 60 Microfiltration (Dot Blotting) Species-Specific Secondary Antibodies 34 Stripping Buffer 60 Antibody-Specific Ligands 34 Blotting Systems and Power Supplies 12 Detection Methods 35 Tank Blotting Cells 12 Colorimetric Detection 36 Part 3 Troubleshooting 63 Mini Trans-Blot® Cell and Criterion™ Blotter 12 Premixed and Individual Colorimetric Substrates 38 Transfer 64 Trans-Blot® Cell 12 Immun-Blot® Assay Kits 38 Electrophoretic Transfer 64 Trans-Blot® Plus Cell 13 Immun-Blot Amplified AP Kit 38 Microfiltration 65 Semi-Dry Blotting Cells
    [Show full text]
  • Blotting Complete Mini Mini Electro Blot System Electro Blot System
    Blotting Complete Mini Mini Electro Blot System Electro Blot System Complete Mini MEBM10 Sub Blot System MEBM10 / MSB10 MV-10CBS Electro Blot Systems are primarily designed for wet electrophoresis of proteins, and offer a combination of increased capacity with economical features. Electro Blot Systems have increased capacity over standard systems. Up to five gel blot cassettes may be utilized at any time for Electro Blot Mini. This is especially intensity coiled electrode and ensures uniform transfer across the blot surface. The cassette’s open architecture that ensures the maximum blot area allows direct transfer of current. Its rigid construction that ensures contact between the gel and membrane is retained throughout the blot and an even pressure is maintained. These units are compatible with magnetic stirrers to aid heat dispersal and prevent pH drifts in the buffer due to incomplete buffer mixing. Each unit includes a cooling pack to further enhance transfer efficiency by removing excess heat. This also saves buffer for added economy. The Complete Electrophoresis Systems include both modules for gel electrophoresis, electroblotting and accessories, to provide a complete Mini gel Complete Mini Electro & Blot System casting, running and electroblotting system. The electroblotting module includes four inter-locking cassettes and sixteen fiber pads. A high intensity current is generated by coiled platinum electrodes. These features, in conjunction with the advanced cooling system allow for rapid electroblotting in as little as one hour. MV-10CBS For MEBM series Features • Ideal for wet electroblotting of proteins – Western Blotting • Hinged cassettes for added convenience • Accommodates gel thickness from 0.25 to 3mm For MV-CBS series Features • Versatile: Interchangeable modules for slab gel and Electroblotting using a single universal buffer tank • Hinged cassettes • High intensity electrodes • blot capacity • Rapid set-up cooling 32 Blotting Cat.
    [Show full text]
  • Two-Dimensional Electrochromatography/Capillary Electrophoresis on a Microchip
    Frederick Conference on Capillary Electrophoresis, Hood College, Frederick, Maryland October 16-28, 2000 Two-Dimensional Electrochromatography/Capillary Electrophoresis on a Microchip Norbert Gottschlich, Stephen C. Jacobson, Christopher T. Culbertson, and J. Michael Ramsey Oak Ridge National Laboratory, Oak Ridge, TN 37831-6142 Two-dimensional (2D) separation methods for the analysis of complex protein or peptide mixtures have mostly been performed on planar gels using isoelectric focusing and polyacrylamide gel electrophoresis (IEF-PAGE). However, these techniques can be slow and labor intensive. Recently, several column-based two-dimensional separation schemes have been developed to reduce the analysis time. Another approach is to use microfluidic devices (microchips) that enable very fast and efficient separations. Furthermore, microchips are relatively easy to operate and allow the manipulation of very small sample volumes with minimal dead volumes between interconnecting channels. These features are especially useful for the development of multidimensional separations. We will report a comprehensive two-dimensional separation system on a microfabricated device that utilizes open-channel electrochromatography as the first dimension and capillary electrophoresis as the second dimension. The first dimension is operated under isocratic conditions, and its effluent is injected into the second dimension every few seconds. A 25 cm long separation channel with spiral geometry for the first dimension, chemically modified with octadecylsilane, is coupled to a 1.2 cm long straight separation channel for the second dimension. Fluorescently labeled products from tryptic digests of proteins are analyzed in 13 minutes with this system. Research sponsored by Office of Research and Development, U.S. Department of Energy, under contract DE-AC05-00OR22725 with Oak Ridge National Laboratory, managed and operated by UT-Battelle, LLC..
    [Show full text]
  • Pulsed Field Gel Electrophoresis
    Pulsed Field Gel Electrophoresis Protocol Bulletin 6229 Optimizing Sample Resolution Switch Time and Switch Time Ramping Switch time is the critical parameter in achieving the best pulsed field gel electrophoresis (PFGE) resolution. It is the length of time the electrical field is pulsed in a single direction. For example, a 60 sec switch time means that the electrical field will be pulsed in one direction for 60 sec and then switched to the other direction for 60 sec. The switch time is generally shorter for samples with small DNA fragments and longer for samples with large DNA fragments. Samples with a wide range of DNA fragment sizes, for example the Saccharomyces cerevisiae chromosomes, can be resolved by changing the switch time over the course of the run. This is referred to as switch time ramping because the switch time will “ramp up” from a short switch time to a longer one. The ramp of the switch time can be linear, that is, increasing in exact increments over the course of a run, or nonlinear, so that the user can concentrate the switch times on the largest or smallest regions as necessary to achieve better resolution. The nonlinear switch time ramping expands the linear range of fragment separation to 50–700 kb, yielding more precise fragment size measurements. 45 sec 60 sec 90 sec The nonlinear ramp is described by how much of the run time has elapsed by the time the user has ramped up to 50% Effect of switch time on sample resolution. As the switch time increases, the larger DNA fragments move farther into the gel during the same time period.
    [Show full text]
  • Analytical Separations Using Packed and Open-Tubular Capillary Electrochromatography" (2004)
    Louisiana State University LSU Digital Commons LSU Doctoral Dissertations Graduate School 2004 Analytical separations using packed and open- tubular capillary electrochromatography Constantina P. Kapnissi Louisiana State University and Agricultural and Mechanical College, [email protected] Follow this and additional works at: https://digitalcommons.lsu.edu/gradschool_dissertations Part of the Chemistry Commons Recommended Citation Kapnissi, Constantina P., "Analytical separations using packed and open-tubular capillary electrochromatography" (2004). LSU Doctoral Dissertations. 595. https://digitalcommons.lsu.edu/gradschool_dissertations/595 This Dissertation is brought to you for free and open access by the Graduate School at LSU Digital Commons. It has been accepted for inclusion in LSU Doctoral Dissertations by an authorized graduate school editor of LSU Digital Commons. For more information, please [email protected]. ANALYTICAL SEPARATIONS USING PACKED AND OPEN- TUBULAR CAPILLARY ELECTROCHROMATOGRAPHY A Dissertation Submitted to the Graduate Faculty of the Louisiana State University and Agricultural and Mechanical College in partial fulfillment of the requirements for the degree of Doctor of Philosophy in The Department of Chemistry by Constantina P. Kapnissi B.S., University of Cyprus, 1999 August 2004 Copyright 2004 Constantina Panayioti Kapnissi All rights reserved ii DEDICATION I would like to dedicate this work to my husband Andreas Christodoulou, my parents Panayiotis and Eleni Kapnissi, and my sisters Erasmia, Panayiota and Stella Kapnissi. I want to thank all of you for helping me, in your own way, to finally make one of my dreams come true. Thank you for encouraging me to continue and achieve my goals. Thank you for your endless love, support, and motivation. Andreas, thank you for your continuous patience and for being there for me whenever I needed you during this difficult time.
    [Show full text]
  • Introduction to Capillary Electrophoresis
    Contents About this handbook..................................................................................... ii Acronyms and symbols used ....................................................................... iii Capillary electrophoresis ...............................................................................1 Electrophoresis terminology ..........................................................................3 Electroosmosis ...............................................................................................4 Flow dynamics, efficiency, and resolution ....................................................6 Capillary diameter and Joule heating ............................................................9 Effects of voltage and temperature ..............................................................11 Modes of capillary electrophoresis ..............................................................12 Capillary zone electrophoresis ..........................................................12 Isoelectric focusing ...........................................................................18 Capillary gel electrophoresis ............................................................21 Isotachophoresis ...............................................................................26 Micellar electrokinetic capillary chromatography ............................28 Selecting the mode of electrophoresis .........................................................36 Approaches to methods development by CZE and MECC .........................37
    [Show full text]
  • A Technology Overview and Applications of Bio-MEMS
    INSTITUTE OF SMART STRUCTURES AND SYSTEMS (ISSS) JOURNAL OF ISSS J. ISSS Vol. 3 No. 2, pp. 39-59, Sept. 2014. REVIEW ARTICLE A Technology Overview and Applications of Bio-MEMS Nidhi Maheshwari+, Gaurav Chatterjee+, V. Ramgopal Rao. Department of Electrical Engineering, Indian Institute of Technology Bombay, Mumbai, India-400076. Corresponding Author: [email protected] + Both the authors have contributed equally. Keywords: Abstract Bio-MEMS, immobilization, Miniaturization of conventional technologies has long cantilever, micro-fabrication, been understood to have many benefits, like: lower cost of biosensor. production, lower form factor leading to portable applications, and lower power consumption. Micro/Nano fabrication has seen tremendous research and commercial activity in the past few decades buoyed by the silicon revolution. As an offset of the same fabrication platform, the Micro-electro-mechanical- systems (MEMS) technology was conceived to fabricate complex mechanical structures on a micro level. MEMS technology has generated considerable research interest recently, and has even led to some commercially successful applications. Almost every smart phone is now equipped with a MEMS accelerometer-gyroscope system. MEMS technology is now being used for realizing devices having biomedical applications. Such devices can be placed under a subset of MEMS called the Bio-MEMS (Biological MEMS). In this paper, a brief introduction to the Bio-MEMS technology and the current state of art applications is discussed. 1. Introduction Generally, the Bio-MEMS can be defined as any The interdisciplinary nature of the Bio-MEMS research is system or device, which is fabricated using the highlighted in Figure 2. This highlights the overlapping of micro-nano fabrication technology, and used many different scientific disciplines, and the need for a healthy for biomedical applications such as diagnostics, collaborative effort.
    [Show full text]
  • Electroblot Proteins by Wet Or Semi-Dry Transfer
    TECH TIP #73 Electroblot proteins by wet or semi -dry transfer TR0073.1 Introduction Typical Western blotting experiments involve polyacrylamide gel electrophoresis (PAGE) of protein samples followed by transfer of the size-separated proteins from gel to nitrocellulose or PVDF membrane. Bands or spots of specific proteins are then visualized on the membrane surface when probed with antibodies and detected with enzyme-substrate reporter systems. Three different methods can be used for protein transfer: passive-diffusion blotting, vacuum blotting, and electroblotting. Among these methods, electroblotting is the most popular because it is both faster and more efficient than the others. Electrophoretic transfer also is more quantitative. Proteins are transferred by an electric current passed through the gel. Wet (tank) transfer and semi-dry transfer have been developed to electrophoretically blot proteins and nucleic acids from gels to membranes. Transfer efficiency in these two variants of electroblotting is dependant upon gel type, membrane type, transfer buffer composition, equilibration time, size of protein(s), transfer temperature, number of gels, and volume of buffer. The purpose of this Tech Tip is to provide very simple, generalized protocols for wet and semi-dry transfer of proteins from standard mini gels (approx. 10cm × 10cm) using typical commercial transfer devices and power supplies. When possible consult and follow the instructions for the specific equipment you own. Relevant Thermo Scientific™ Pierce™ products are mentioned in each protocol, and a fuller list of these products occurs at the end this document. Protein blotting using a wet (tank) transfer apparatus 1. Separate the proteins in the sample by gel electrophoresis (e.g., reducing, denaturing SDS-PAGE).
    [Show full text]
  • Dielectrophoretic Manipulation and Separation of Microparticles Using Microarray Dot Electrodes
    Sensors 2014, 14, 6356-6369; doi:10.3390/s140406356 OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Article Dielectrophoretic Manipulation and Separation of Microparticles Using Microarray Dot Electrodes Bashar Yafouz 1,2, Nahrizul Adib Kadri 1,2,* and Fatimah Ibrahim 1,2 1 Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia; E-Mails: [email protected] (B.Y.); [email protected] (F.I.) 2 Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +6-037-967-4581; Fax: +6-037-967-4579. Received: 15 November 2013; in revised form: 7 March 2014 / Accepted: 14 March 2014 / Published: 3 April 2014 Abstract: This paper introduces a dielectrophoretic system for the manipulation and separation of microparticles. The system is composed of five layers and utilizes microarray dot electrodes. We validated our system by conducting size-dependent manipulation and separation experiments on 1, 5 and 15 μm polystyrene particles. Our findings confirm the capability of the proposed device to rapidly and efficiently manipulate and separate microparticles of various dimensions, utilizing positive and negative dielectrophoresis (DEP) effects. Larger size particles were repelled and concentrated in the center of the dot by negative DEP, while the smaller sizes were attracted and collected by the edge of the dot by positive DEP. Keywords: dielectrophoresis (DEP); microparticle separation; dot electrode; microfluidics; BioMEMS 1. Introduction Particle manipulation and separation techniques have been of interest to many research groups worldwide for various biomedical applications, including cell concentration, separation, patterning, Sensors 2014, 14 6357 trapping and positioning [1].
    [Show full text]