Summary of Requirement for PWD Toilets (Not Within an SOU) – As Per AS1428.1-2009
Total Page:16
File Type:pdf, Size:1020Kb
Summary of Requirement for PWD Toilets (not within an SOU) – as per AS1428.1-2009 Fixture Aspect and/or Key Requirement Diagram 1900 mm wide x PWD Toilet Minimum Size NOTE: Extra space may be required to allow for the a washbasin. 2300 mm long WC Height 460 to 480 mm (to top of seat) Centre of WC 450 to 460 mm (from side wall) From back wall 800 mm ± 10 mm Front of WC From cistern or like Min. 600 mm Top of WC Seat Height of Zone to 700 mm Toilet Paper Dispenser WC Distance of Zone Max. 300mm from Front of QC Height 150 to 200 mm Width 350 to 400 mm Backrest Distance above WC Seat 120 to 150 mm Angle from Seat Hinge 90° to 100° Height Grabrails 800 to 810 mm (to top of grab rail) Height 800 – 830 mm (to top of washbasin) Centre of Washbasin Washbasin Min. 425 mm (from side wall) Operable Parts of Tap Max. 300 mm (from front of washbasin) Width Min. 350 mm Mirror Height Min. 950 mm Not available (if provided) Fixing Location / Extent of Mirror 900 – 1850 mm Height 900 – 1100 mm Soap / Paper Towel Not available Dispenser Distance from Internal Corner Min. 500 mm Summary of Requirement for PWD Toilets (not within an SOU) – as per AS1428.1-2009 Fixture Aspect and/or Key Requirement Diagram Height 1200 – 1350 mm PWD Clothes Hook Not available Distance from Internal Corner Min. 500 mm Height 800 – 830 mm As vanity bench top Width Min. 120 mm Depth 300 – 400 mm Shelves Not available Height 900 – 1000 mm As separate fixture (if within any required Width 120 – 150 mm circulation space) Length 300 – 400 mm Width Min. 1160 mm (wall with shower) Shower recess Length Min. 1100 mm (wall with seat) Width 390 – 400 mm Length Min. 1000 mm Folding seat Top of Seat Height 470 – 480 mm (when folded down) Height 1880 – 1900 mm (at top of rail) Vertical Shower Height 1000 – 1100 mm Rail (at bottom of rail) Centre 580 – 600 mm (from nearest side wall) Shower Height 900 – 1100 mm (with two walls) Clearance Zone for Taps & Min. 50 mm (from shower rail) Soap Holder Distance from wall 300 – 800 mm (nearest side wall) Height 800 – 810 mm Length Min. 600 mm Grabrail Start Point 390 – 400 mm (from side wall) Length of hose Min. 1500 mm Shower Hose/Head Wall outlet position 700 ± 5 mm Distance from Seat 400 ± 10 mm (First Hook) Clothes Hooks (x 2) Distance from Seat 600 ± 10 mm (Second Hook) Height To Table Surface Max. 820 mm Baby Change Table Not available (when open) Clearance Underneath Min. 720 mm Compartment Width 900 – 920 mm Door clear opening width Min. 700 mm Pan Height 460 – 480 mm Height 800 – 810 mm Ambulant Toilet Grabrails Location Both sides Clearance space in front of pan 900mm x 900mm Coat Hook Height 1350 – 1500 mm Toilet Paper Dispenser Location As per PWD WC .