For Thermosiphon Heaters
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Installation Guide
Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/Support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International) Compatible systems ecobee3 works with most centralized residential heating and cooling systems. Heating: up to 2 stages Cooling: up to 2 stages Heat pumps: 1 or 2 stages + up to 2 stages auxiliary heat Accessories: Dehumidifier, humidifier or ventilation device 3 Items included in box A ecobee3 thermostat with D Large trim plate back plate and trim plate E Screws and drywall plugs B Remote Sensor and stand F Information booklets C Power Extender Kit G Double-sided adhesives (optional) A B C wire labels Installation Guide Quick Start Guide D E F G 4 Items you’ll need A Phillips screwdriver B Drill for mounting anchors with 3⁄₁₆ inch drill bit A B Tip: Review all the instructions before you start to ensure that there are no surprises during installation. Tip: For accurate temperature readings, install your ecobee3 in a conditioned space, on an interior wall, and away from direct heat sources. 5 Overview of steps Installing your ecobee3 home climate system is easy. Just follow these steps and you’ll be done before you know it. Step 1 Power off your HVAC system page 8 Before doing anything else, power off your system. Step 2 Label the wires page 9 Label each wire with the provided stickers. Step 3 Install Power Extender Kit page 11 The PEK is not required for all installs. -
Icomfort S30 Smart Thermostat Installation and Setup Guide
iComfort® S30 Smart Thermostat Installation and Setup Guide Color Touchscreen Programmable Wi-Fi Communicating Thermostat (12U67) 507536-02 5/2017 Supersedes 10/2016 Software Version 3.2 TABLE OF CONTENTS SHIPPING AND PACKING LIST ............................................. 3 Mag-Mount....................................................... 33 GENERAL ................................................................. 3 Add / Remove Equipment........................................... 33 INSTALLING CONTROL SYSTEM COMPONENTS ............................. 4 Reset ............................................................ 33 Smart Hub Installation................................................... 4 Notifications ........................................................... 33 Mag-Mount Installation.................................................. 5 Tests ................................................................. 33 HD Display External Components......................................... 6 Diagnostics ............................................................ 33 HD Display Installation.................................................. 6 Installation Report...................................................... 33 WIRING FOR CONTROL SYSTEM COMPONENTS............................. 7 Information ............................................................ 34 CONFIGURATING HEAT SECTIONS ON AIR HANDLER CONTROL.............. 12 Dealer — Information............................................... 34 SMART HUB OPERATIONS................................................ -
Modeling and Optimization of a Thermosiphon for Passive Thermal Management Systems
MODELING AND OPTIMIZATION OF A THERMOSIPHON FOR PASSIVE THERMAL MANAGEMENT SYSTEMS A Thesis Presented to The Academic Faculty by Benjamin Haile Loeffler In Partial Fulfillment of the Requirements for the Degree Master of Science in the G. W. Woodruff School of Mechanical Engineering Georgia Institute of Technology December 2012 MODELING AND OPTIMIZATION OF A THERMOSIPHON FOR PASSIVE THERMAL MANAGEMENT SYSTEMS Approved by: Dr. J. Rhett Mayor, Advisor Dr. Sheldon Jeter G. W. Woodruff School of Mechanical G. W. Woodruff School of Mechanical Engineering Engineering Georgia Institute of Technology Georgia Institute of Technology Dr. Srinivas Garimella G. W. Woodruff School of Mechanical Engineering Georgia Institute of Technology Date Approved: 11/12/2012 ACKNOWLEDGEMENTS I would like to first thank my committee members, Dr. Jeter and Dr. Garimella, for their time and consideration in evaluating this work. Their edits and feedback are much appreciated. I would also like to acknowledge my lab mates for the free exchange and discussion of ideas that has challenged all of us to solve problems in new and better ways. In particular, I am grateful to Sam Glauber, Chad Bednar, and David Judah for their hard work on the pragmatic tasks essential to this project. Andrew Semidey has been a patient and insightful mentor since my final terms as an undergrad. I thank him for his tutelage and advice over the years. Without him I would have remained a mediocre heat transfer student at best. Andrew was truly indispensable to my graduate education. I must also thank Dr. Mayor for his guidance, insight, and enthusiasm over the course of this work. -
Dodge Cummins Coolant Bypass
FPE-2018-06 SUBJECT: DODGE CUMMINS COOLANT BYPASS KIT November, 2020 Page 1 of 6 FITMENT: 2003–2007 Dodge Cummins Manual Transmission Only 2007.5-2018 Dodge Cummins Manual and Automatic Transmissions KIT P/N: FPE-CLNTBYPS-CUMMINS-MAN, FPE-CLNTBYPS-CUMMINS-6.7 ESTIMATED INSTALLATION TIME: 2-3 Hours TOOLS REQUIRED: 16mm ratcheting wrench, 10mm socket, 8mm socket, 6mm Allen, 1” wrench, hammer, 5-gallon clean drain pan, 36” pry bar, Scotch-Brite TM pad (included in kit). KIT CONTENTS: Item Description Qty 1 Coolant bypass hose 1 2 Coolant bypass thermostat housing 1 and O-ring 3 Thermostat riser block and O-ring 1 3 4 4 Coolant bypass hose riser bracket 2 2 5 M8 x 1.25, 20mm socket head cap 2 screw 7 6 6 M6 x 1.00 x 60mm flange head bolt 3 5 7 M12 x 1.75, 40mm flange head bolt 2 8 Scotch-Brite TM pad (not pictured) 1 1 WARNINGS: • Use of this product may void or nullify the vehicle’s factory warranty. • User assumes sole responsibility for the safe & proper use of the vehicle at all times. • The purchaser and end user releases, indemnifies, discharges, and holds harmless Fleece Performance Engineering, Inc. from any and all claims, damages, causes of action, injuries, or expenses resulting from or relating to the use or installation of this product that is in violation of the terms and conditions on this page, the product disclaimer, and/or the product installation instructions. Fleece Performance Engineering, Inc. will not be liable for any direct, indirect, consequential, exemplary, punitive, statutory, or incidental damages or fines cause by the use or installation of this product. -
Modeling and Simulation of a Thermosiphon Solar Water Heater in Makurdi Using Transient System Simulation
International Journal of Scientific & Engineering Research Volume 10, Issue 12, December-2019 451 ISSN 2229-5518 Modeling and Simulation of a Thermosiphon Solar Water Heater in Makurdi using Transient System Simulation Prof. Joshua Ibrahim, Dr. Aoandona Kwaghger, Engr. Shehu Mohammed Sani ABSTRACT The modeling and simulation of a thermosyphon solar water heater at Makurdi (7.74oN) Nigeria was conducted for a period of three months (November, 2013- January, 2014). The research was aimed at simulating the performance of a solar water heater by using various parameters for greater efficiency. The solar water heater was developed and its performance was simulated at University of Agriculture Makurdi. The solar radiation on a horizontal surface was measured using a solarimeter. The water mass flow rates were measured using a Flow meter. The relative humidity data were measured using the Hygrometer. The inlet, outlet and ambient temperatures were measured using a Digital thermometer. For the simulation of the entire system the following measured parameters were used, as global solar radiation on collector plate, collector ambient temperature, heat exchanger and storage tank ambient temperature, flow rate of the collector and storage loop, the cold tap water temperature and the hot water usage. For the validation of the model and for the identification of parameters as heat loss coefficients in situ measurements were performed. Based on the developed models parameter sensitivity analysis and transient influences can be examining for the element and the entire system as well. The results obtained were simulated using Transient simulation software16 (TRNSYS). The results obtained showed that the daily average solar radiation for the period varied from 405 푊/푚2 to1008 푊/푚2. -
And Tec220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers
TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Code No. LIT-12011611 Technical Bulletin Issued February 8, 2010 Network Variables (NVs) and Configuration Parameters (CPs) List. 3 Network Variable Inputs (NVIs) Table . 8 Network Variable Outputs (NVOs) Table . 10 Configuration Properties (CPs) . 13 Space Comfort Controller Object . 18 Commissioning the Thermostat Using a LONWORKS Network Configuration Tool . 18 Service Pin . 19 TEC22xx-4 Configuration Plug-in. 19 Installing the Plug-in. 19 Registering the Plug-in. 20 Using LN Browser to Display NVs, NCIs, and CPs . 22 Running the Plug-in . 27 Heating - Cooling Tab . 31 Hardware Tab . 32 General Tab . 33 Model Tab . 34 Scheduler Tab . 36 Network Tab . 38 About Tab . 39 Adding a Thermostat to the Network Automation Engine (NAE) . 39 LONWORKS Thermostat Controller Mapping . 40 Preparation . 40 Troubleshooting Guide . 40 Technical Specifications . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged 1 Thermostat Controllers Technical Bulletin 2 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin Network Variables (NVs) and Configuration Parameters (CPs) List Table 1 shows the NVs and CPs for the TEC226x-4(+PIR) and TEC220x-4(+PIR) Series Thermostat Controllers. Each Network Variable Input (NVI), Network Variable Output (NVO), and Network Configuration Input (NCI) has a reference number as defined in the XIF Resource File, and some objects have a subcategory number. -
Room Humidistat and Thermostat Combination, Wall Mounting, For
Room humidistat and thermostat combination, wall mounting, for swimming pools areas and air conditioning Type Q4 DIMENSIONS MAIN FEATURES Main Application: This device is a combination of a humidistat and a room thermostat. It is especially suited for use in air conditioning control of indoor swimming-pool halls.His aesthetics and small size housing (122x70x31mm) allows mounting in most of these applications, but must be protected from splashing water, and used only in ambient air free of chemical contamination or corrosive ingredients. It is designed to turn on heating or cooling, ventilation, humidifiers, dehumidifiers, and heat pumps. It must be vertically wall mounted in a naturally ventilated area Humidity sensing element: hygroscopic polymer film with special treatment, produced by Ultimheat, ensuring a fast response, long life and high stability Humidity setting range: 35 to 95% RH Humidity measuring accuracy: ±5% RH Differential at 50% RH: 8% RH (±3% RH ) Measuring medium: air, pressure-less, non-aggressive Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in humidifier, dehumidifier or ventilation control. Maintenance: The humidity sensing ribbon is maintenance-free in clean air. Air containing solvent can cause measuring errors and failure, depending on the type and concentration. Deposits such as resin aerosols, lacquer aerosols, smokes, which eventually form a water-repellent film are harmful for the measuring element. Temperature measuring element: Bimetal strip Temperature adjustment range: 5-35°C Differential: 0.6+/-0.3°C Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in heating or cooling applications Options: • On Off switch • Thermal anticipator, that provides thermal differential reduction (Needs Neutral+ Line power supply, 230 or 24V) • Remote set point reduction (Needs Neutral+ Line power supply, 230 or 24V) • Temperature printings in °F Connection: screw terminal connection block for 1.5mm² wires, max torque 0.5Nm Mounting: wall mounting, with 2 screws dia 4 mm max, distance 100 x 50 mm. -
Installation, Setup & Troubleshooting Supplement
EconoMi$er X F a c t o r y --- I n s t a l l e d O p t i o n Low Leak Economizer for 2 Speed SAV (Staged Air Volume) Systems Installation, Setup & Troubleshooting Supplement This document is a supplemental installation instruction for the factory-installed EconoMi$er X (low leak economizer) option. It is to be used with the base unit Installation Instructions for 48/50TC, 50TCQ, 48/50HC, and 50HCQ 2-Stage cooling units, sizes 08 – 30. Units equipped with the EconoMi$er X option are identified by an indicator in the unit's model number (see the unit's nameplate). Use Table 1 (on page 2) to identify whether or not a given unit is equipped with the factory-installed EconoMi$er X. NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS SAFETY CONSIDERATIONS.................... 1 Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical GENERAL.................................... 2 shock or other conditions which may cause personal injury Identifying Factory Option...................... 2 or property damage. Consult a qualified installer, service EconoMi$er X................................ 3 agency, or your distributor or branch for information or assistance. The qualified installer or agency must use W7220 Economizer Controller................... 3 factory--authorized kits or accessories when modifying this User Interface................................ 3 product. Refer to the individual instructions packaged with Menu Structure............................... 3 the kits or accessories when installing. Checkout Tests............................... 7 Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and SETUP AND CONFIGURATION................ -
SOLAR HEATING CONTROLS by Radiantec Company
SOLAR HEATING CONTROLS by Radiantec Company THE SOLAR CONTROL LOOP Solar Loop Control Sensors Solar Control (cover off) OPERATION- The solar loop control turns on the solar loop pump whenever solar energy is available and turns the pump off when sufficient solar energy is no longer available. (See the appendix for a detailed dis- cussion of control operation) CONTROLLER LOGIC- The solar loop control is a “differential temperature control”. It senses temperature at two locations and operates according to the difference between the temperatures at these two locations. When the temperature of the “collector” sensor is 8° F warmer, or more, than the “storage/tank” sensor, the output switch is closed. (that action turns the pump on) When the temperature of the “collector” sensor is only 4° F, or less, warmer than the “storage/tank” sensor, the output switch is opened.(That action turns the pump off ) SENSOR PLACEMENT - Place the “collector” sensor on the outlet pipe of the solar collector array and insulate well. Place the “storage” sensor on the pipe at the point where the flow from the heat exchangers come together in one pipe for return to the solar collectors. Insulate well. See page 16 of the installation manual for sensor placement details. Typical Control Setting Turn on = 8° Hi limit = 200° Optional Temperature Display SOLAR HEATING CONTROLS by Radiantec Company HEAT DUMP CONTROL Heat Dump Valve Place the heat dump valve in any hot water line and plumb to a suitable drain. Laundry room placement can be convenient. Setpoint Control Setpoint Control (cover off) OPERATION - The heat dump control lowers system temperature by automatically consuming some domestic hot water whenever excessive temperatures are detected. -
Viega Digital Thermostat
User Guide Viega Digital Thermostat Features ■ Compact Design ■ Digital LCD Display ■ Regulates Floor or Room Temperature ■ Optional Floor Sensor ■ Setback Function ■ On / Off Switch Specifications ■ Control: Microprocessor control ■ Accuracy: 0.1°F ■ Set Temperature Range: 41 °F - 99 °F, 0.5 °F increments This document is subject to updates. ■ Environment Range: 32 °F - 122 °F For the most current Viega technical ■ Power Supply: 24 VAC +/_ 10% literature please visit www.viega.us. 60Hz 15 W max ■ Output: TRIAC output 24 Viega products are designed to be VAC, 15 W max installed by licensed and trained ■ Optional Floor Sensor: NTC thermistor plumbing, mechanical, and electrical (10K Ohms), 10 cable professionals who are familiar with Viega ■ Floor limiting range: 41°F - 98.6°F products and their installation. Installation ■ Electrical Protection: Class II - IP30 by non-professionals may void Viega LLC’s 2.60" warranty. Applications The digital thermostat is ideal for individual room temperature control. A user-friendly, three- button design allows for easy adjustment of settings. The thermostat can sense either room temperature or floor temperature. Adjustable temperature setback function allows for energy savings. The thermostat can control up to four 1.22" 3.15" powerheads directly or can be connected to a zone / circulator control box. With optional floor sensor, the thermostat provides floor high or low limit function for floor protection or floor warming. UG-HC 560621 0120 Digital Thermostat (EN) 1 of 8 Viega Digital Thermostat User Guide Installation ■ Remove oval rubber plug from front of °F °C thermostat faceplate. ■ Using a small Phillips screwdriver remove screw securing thermostat faceplate to Cover Screw mounting plate. -
Solar Water Heating System Requirements
Solar Water Heating Installation Requirements Adapted from The Bright Way to Heat Water™ technical requirements V 27 Energy Trust of Oregon Solar Water Heating Installation Requirements Revisions Energy Trust updates these installation requirements annually. Many thanks to the industry members and technical specialists that have invested their time to help keep this document current. The current document (v 27) underwent significant changes from previous installation requirements. Much of the redundant commentary material was removed and many requirements were evaluated based on cost effectiveness and removed or relaxed. The revisions table below summarizes many of the new changes however this document should be read in its entirety to understand the changes. August, 2012 Revisions Section Revision 2.2 Changed requirement for avoiding galvanic action, allowing aluminum Materials to galvanized steel connections. Requirements related to overheat and freeze protection were moved 2.3 to the new Solar Water Heating System Design and Eligibility Equipment and Installation Requirements document. Water quality requirements were removed. Requirements related to heat exchanger materials were moved to the 2.6 new Solar Water Heating System Design and Eligibility Requirements Plumbing document. Parts of Section 2.10 from v 26 were integrated into section 2.6. Backup water heater requirements were removed and/or deferred to code. 2.8 Anti-convective piping requirements were removed. Backup Water Heater Backup water heater R-10 floor pad was removed. Parts of Section 2.10 from v 26 were integrated into section 2.8 2.9 Storage to collector ratios were revised for single tank systems and moved to the new Solar Water Heating System Design and Eligibility Solar Storage Tank Requirements document. -
Tec22x6(H)-2 Series LONWORKS® Network Thermostats with Two Outputs, Dehumidification Capability, and Three Code No
TEC22x6(H)-2 Series LONWORKS® Network Thermostats with Two Outputs, Dehumidification Capability, and Three Code No. LIT-12011118 Speeds of Fan Control Issued August 11, 2006 Product Bulletin Supersedes May 24, 2006 The TEC22x6(H)-2 Series Thermostats are LONWORKS® network devices that provide control of two- or four-pipe fan coils, cabinet unit heaters, or other equipment using on/off, floating, or proportional 0 to 10 VDC control input, dehumidification capability, and up to three speeds of fan control. The technologically advanced TEC22x6(H)-2 Series Thermostats feature a Building Automation System (BAS) LONWORKS network communication capability that enables remote monitoring and programmability for efficient space temperature control. Specific models are available to accommodate commercial and hospitality applications. The TEC22x6(H)-2 Series Thermostats feature an intuitive user interface with backlit display that makes setup and operation quick and easy. The thermostats also employ a unique, Proportional-Integral (PI) time-proportioning algorithm that virtually eliminates Figure 1: TEC22x6-2 Series LONWORKS temperature offset associated with traditional, Network Thermostat with Two Outputs, differential-based thermostats. Dehumidification Capability, and Three Speeds of Fan Control Table 1: Features and Benefits Features Benefits LONWORKS Network Communication Provides compatibility with a proven communication network; LONWORKS network is widely accepted by Heating, Ventilating, and Air Conditioning (HVAC) control suppliers. Integral Humidity Sensing Capability and Increases occupancy comfort by providing dehumidification. Dehumidification Capability (Dehumidification Models) Backlit Liquid Crystal Display (LCD) Offers real-time control status of the environment in easy-to-read, English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Offers additional application flexibility by providing more advanced control Control signals.