Compact Wall Mounted Type MANUAL DE INSTRUÇÕES

Total Page:16

File Type:pdf, Size:1020Kb

Compact Wall Mounted Type MANUAL DE INSTRUÇÕES Compact Wall Mounted Type MANUAL DE INSTRUÇÕES GUARDE ESTE MMANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA PART NO.9332280029-04 99332280029-04_OM.indb332280029-04_OM.indb 1 22/25/2013/25/2013 33:27:48:27:48 PPMM CONTENTS SAFETY PRECAUTIONS ......................................En-1 ECONOMY OPERATION ....................................En-11 FEATURES AND FUNCTIONS .............................En-2 10°C HEAT OPERATION ....................................En-12 NAME OF PARTS .................................................En-3 MANUAL AUTO OPERATION .............................En-12 PREPARATION .....................................................En-5 CLEANING AND CARE .......................................En-12 OPERATION ..........................................................En-6 SELECTING THE REMOTE CONTROLLER TIMER OPERATION .............................................En-8 SIGNAL CODE ....................................................En-15 SLEEP TIMER OPERATION .................................En-9 TROUBLESHOOTING ........................................En-16 ADJUSTING THE DIRECTION OF AIR OPERATING TIPS ...............................................En-17 CIRCULATION ....................................................En-10 SWING OPERATION ..........................................En-11 SAFETY PRECAUTIONS ● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way. ● The instructions in this section all relate to safety; be sure to maintain safe operating conditions. ● “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions: This mark indicates procedures which, if improperly performed, are most likely to result in DANGER! the death or serious injury to the user or service personnel. This mark indicates procedures which, if improperly performed, might lead to the death or WARNING! serious injury of the user or service personnel. This mark indicates procedures which, if improperly performed, might possibly result in CAUTION! personal harm to the user, or damage to property. ● Do not attempt to install this air conditioner by yourself. DANGER! ● This air conditioner contains no user-serviceable parts. Always consult authorized service personnel for repairs. ● When moving, consult authorized service personnel for disconnection and installation of the air conditioner. ● Do not become excessively chilled by staying for many hours in the direct cooling airfl ow. ● Do not insert fi ngers or objects into the outlet port or intake grille. ● Do not start and stop air conditioner operation by disconnecting the power supply cord. ● Take care not to damage the power supply cord. ● If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specifi ed cord are required. ● In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the breaker, and consult author- ized service personnel. ● In the event of refrigerant leakage, be sure to keep away from fi re or any fl ammables. (consult an authorized service per- sonnel) ● Provide occasional ventilation during use. CAUTION! ● Do not direct airfl ow at fi replaces or heating apparatus. ● Do not climb on, or place objects on, the air conditioner. ● Do not hang objects from the indoor unit. ● Do not set fl ower vases or water containers on top of air conditioners. ● Do not expose the air conditioner directly to water. ● Do not operate the air conditioner with wet hands. ● Do not pull power supply cord. ● Turn off power supply when not using the indoor unit for extended periods. ● Check the condition of the installation stand for damage. ● Do not place animals or plants in the direct path of the airfl ow. ● Do not drink the water drained from the air conditioner. ● Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works. ● Connection valves become hot during Heating; handle with care. ● Do not apply any heavy pressure to radiator fi ns. ● Operate only with air fi lters installed. ● Do not block or cover the intake grille and outlet port. ● Ensure that any electronic equipment is at least 3.3ft (1m) away from either the indoor or outdoor units. ● Avoid installing the air conditioner near a fi replace or other heating apparatus. ● When installing the indoor and outdoor unit, take precautions to prevent access to infants. ● Do not use infl ammable gases near the air conditioner. ● This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabili- ties, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. En-1 99332280029-04_OM.indb332280029-04_OM.indb SSec1:1ec1:1 22/25/2013/25/2013 33:27:48:27:48 PPMM FEATURES AND FUNCTIONS ■ Energy saving and Comfortable function ■ Clean function INVERTER REMOVABLE INTAKE GRILLE At the start of operation, large amount of power is used to The indoor unit’s intake grille can be removed for easy clean- bring the room quickly to the desired temperature. Afterwards, ing and maintenance. the unit automatically switches to a low power setting for eco- nomic and comfortable operation. MILDEW-RESISTANT FILTER ECONOMY OPERATION The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care. When ECONOMY operation mode is operated, the room tem- perature will be little higher than the set-temp under cooling POLYPHENOL CATECHIN AIR CLEANING FILTER mode and lower than set-temp under heating mode. Therefore, the ECONOMY mode is able to save more energy than other The polyphenol catechin air cleaning fi lter uses static electric- normal mode. ity to clean fi ne particles and dust in the air such as tobacco smoke and plant pollen that are too small to see. The filter SWING OPERATION contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbed to the fi lter. Note that when the air cleaning fi lter is installed, the The Airflow Direction Louvers swings automatically up and amount of air produced decreases, causing a slight decrease down so that the air speeds to every nook and corner of your in the indoor unit’s performance. room. NEGATIVE AIR IONS DEODORIZING FILTER SUPER QUIET OPERATION It comprises pottery super micro particles which can produce When the FAN button is used to select QUIET, the indoor unit negative air ions having the effect of deodorizing and can ab- begins super quiet operation; the indoor unit’s airflow is re- sorb and remit the peculiar smell at home. duced to produce quieter operation. AUTO CHANGEOVER ■ Remote controller The operation mode (cooling, dry, heating) is switched auto- WIRELESS REMOTE CONTROLLER matically to maintain the set temperature, and the temperature is kept constant at all times. The wireless remote controller allows convenient control of air conditioner operation. 10°C HEAT OPERATION WIRED REMOTE CONTROLLER (OPTION) The room temperature can be maintained at 10°C so as to prevent the room temperature from falling too far. The optional wired remote controller can be used. When you use remote controller, there are following different points as ■ Convenient function compared with using wireless remote controller. [The additional functions for wired ones] • Weekly timer PROGRAM TIMER • Temperature set back timer And you can use both wired and wireless remote controller si- The program timer allows you to integrate OFF timer and ON timer multaneously. (But function is limited) operations in a single sequence. The sequence can involve 1 tran- When the restricted functions on the remote controller are sition from OFF timer to ON timer, or from ON timer to OFF timer, used, beeping sound will be heard, OPERATION, TIMER and within a 24 hour period. the 3rd lamp of the indoor unit will fl ash. SLEEP TIMER [The restricted functions for wireless ones] • 10°C HEAT OPERATION • PROGRAM TIMER When the SLEEP timer button is pressed during heating mode, • SLEEP TIMER the air conditioner’s thermostat setting is gradually lowered dur- ing the period of operation; during cooling or dry mode, the ther- mostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off. En-2 99332280029-04_OM.indb332280029-04_OM.indb SSec1:2ec1:2 22/25/2013/25/2013 33:27:48:27:48 PPMM NAME OF PARTS Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators; in actual operation, however, the display will only show those indicators appropriate to the current operation. En-3 99332280029-04_OM.indb332280029-04_OM.indb SSec1:3ec1:3 22/25/2013/25/2013 33:27:48:27:48 PPMM Fig. 1 Indoor Unit Fig. 5 Remote Controller 1 Operating Control Panel (Fig. 2) D Signal Transmitter 2 MANUAL AUTO button E ● When the MANUAL AUTO button is MODE button pressed in for more than 10 seconds, the F 10˚C HEAT button forced cooling operation will start. G ECONOMY button ● The forced cooling operation is used at H SLEEP button the time of installation. Only for authorized service personnel's I TIMER MODE button use. J FAN button ● When the forced cooling operation starts K START/STOP button by any chance, press the START/STOP L button to stop the operation. SET button (Vertical) ●
Recommended publications
  • Installation Guide
    Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/Support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International) Compatible systems ecobee3 works with most centralized residential heating and cooling systems. Heating: up to 2 stages Cooling: up to 2 stages Heat pumps: 1 or 2 stages + up to 2 stages auxiliary heat Accessories: Dehumidifier, humidifier or ventilation device 3 Items included in box A ecobee3 thermostat with D Large trim plate back plate and trim plate E Screws and drywall plugs B Remote Sensor and stand F Information booklets C Power Extender Kit G Double-sided adhesives (optional) A B C wire labels Installation Guide Quick Start Guide D E F G 4 Items you’ll need A Phillips screwdriver B Drill for mounting anchors with 3⁄₁₆ inch drill bit A B Tip: Review all the instructions before you start to ensure that there are no surprises during installation. Tip: For accurate temperature readings, install your ecobee3 in a conditioned space, on an interior wall, and away from direct heat sources. 5 Overview of steps Installing your ecobee3 home climate system is easy. Just follow these steps and you’ll be done before you know it. Step 1 Power off your HVAC system page 8 Before doing anything else, power off your system. Step 2 Label the wires page 9 Label each wire with the provided stickers. Step 3 Install Power Extender Kit page 11 The PEK is not required for all installs.
    [Show full text]
  • Icomfort S30 Smart Thermostat Installation and Setup Guide
    iComfort® S30 Smart Thermostat Installation and Setup Guide Color Touchscreen Programmable Wi-Fi Communicating Thermostat (12U67) 507536-02 5/2017 Supersedes 10/2016 Software Version 3.2 TABLE OF CONTENTS SHIPPING AND PACKING LIST ............................................. 3 Mag-Mount....................................................... 33 GENERAL ................................................................. 3 Add / Remove Equipment........................................... 33 INSTALLING CONTROL SYSTEM COMPONENTS ............................. 4 Reset ............................................................ 33 Smart Hub Installation................................................... 4 Notifications ........................................................... 33 Mag-Mount Installation.................................................. 5 Tests ................................................................. 33 HD Display External Components......................................... 6 Diagnostics ............................................................ 33 HD Display Installation.................................................. 6 Installation Report...................................................... 33 WIRING FOR CONTROL SYSTEM COMPONENTS............................. 7 Information ............................................................ 34 CONFIGURATING HEAT SECTIONS ON AIR HANDLER CONTROL.............. 12 Dealer — Information............................................... 34 SMART HUB OPERATIONS................................................
    [Show full text]
  • Dodge Cummins Coolant Bypass
    FPE-2018-06 SUBJECT: DODGE CUMMINS COOLANT BYPASS KIT November, 2020 Page 1 of 6 FITMENT: 2003–2007 Dodge Cummins Manual Transmission Only 2007.5-2018 Dodge Cummins Manual and Automatic Transmissions KIT P/N: FPE-CLNTBYPS-CUMMINS-MAN, FPE-CLNTBYPS-CUMMINS-6.7 ESTIMATED INSTALLATION TIME: 2-3 Hours TOOLS REQUIRED: 16mm ratcheting wrench, 10mm socket, 8mm socket, 6mm Allen, 1” wrench, hammer, 5-gallon clean drain pan, 36” pry bar, Scotch-Brite TM pad (included in kit). KIT CONTENTS: Item Description Qty 1 Coolant bypass hose 1 2 Coolant bypass thermostat housing 1 and O-ring 3 Thermostat riser block and O-ring 1 3 4 4 Coolant bypass hose riser bracket 2 2 5 M8 x 1.25, 20mm socket head cap 2 screw 7 6 6 M6 x 1.00 x 60mm flange head bolt 3 5 7 M12 x 1.75, 40mm flange head bolt 2 8 Scotch-Brite TM pad (not pictured) 1 1 WARNINGS: • Use of this product may void or nullify the vehicle’s factory warranty. • User assumes sole responsibility for the safe & proper use of the vehicle at all times. • The purchaser and end user releases, indemnifies, discharges, and holds harmless Fleece Performance Engineering, Inc. from any and all claims, damages, causes of action, injuries, or expenses resulting from or relating to the use or installation of this product that is in violation of the terms and conditions on this page, the product disclaimer, and/or the product installation instructions. Fleece Performance Engineering, Inc. will not be liable for any direct, indirect, consequential, exemplary, punitive, statutory, or incidental damages or fines cause by the use or installation of this product.
    [Show full text]
  • And Tec220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers
    TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Code No. LIT-12011611 Technical Bulletin Issued February 8, 2010 Network Variables (NVs) and Configuration Parameters (CPs) List. 3 Network Variable Inputs (NVIs) Table . 8 Network Variable Outputs (NVOs) Table . 10 Configuration Properties (CPs) . 13 Space Comfort Controller Object . 18 Commissioning the Thermostat Using a LONWORKS Network Configuration Tool . 18 Service Pin . 19 TEC22xx-4 Configuration Plug-in. 19 Installing the Plug-in. 19 Registering the Plug-in. 20 Using LN Browser to Display NVs, NCIs, and CPs . 22 Running the Plug-in . 27 Heating - Cooling Tab . 31 Hardware Tab . 32 General Tab . 33 Model Tab . 34 Scheduler Tab . 36 Network Tab . 38 About Tab . 39 Adding a Thermostat to the Network Automation Engine (NAE) . 39 LONWORKS Thermostat Controller Mapping . 40 Preparation . 40 Troubleshooting Guide . 40 Technical Specifications . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged 1 Thermostat Controllers Technical Bulletin 2 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin Network Variables (NVs) and Configuration Parameters (CPs) List Table 1 shows the NVs and CPs for the TEC226x-4(+PIR) and TEC220x-4(+PIR) Series Thermostat Controllers. Each Network Variable Input (NVI), Network Variable Output (NVO), and Network Configuration Input (NCI) has a reference number as defined in the XIF Resource File, and some objects have a subcategory number.
    [Show full text]
  • Room Humidistat and Thermostat Combination, Wall Mounting, For
    Room humidistat and thermostat combination, wall mounting, for swimming pools areas and air conditioning Type Q4 DIMENSIONS MAIN FEATURES Main Application: This device is a combination of a humidistat and a room thermostat. It is especially suited for use in air conditioning control of indoor swimming-pool halls.His aesthetics and small size housing (122x70x31mm) allows mounting in most of these applications, but must be protected from splashing water, and used only in ambient air free of chemical contamination or corrosive ingredients. It is designed to turn on heating or cooling, ventilation, humidifiers, dehumidifiers, and heat pumps. It must be vertically wall mounted in a naturally ventilated area Humidity sensing element: hygroscopic polymer film with special treatment, produced by Ultimheat, ensuring a fast response, long life and high stability Humidity setting range: 35 to 95% RH Humidity measuring accuracy: ±5% RH Differential at 50% RH: 8% RH (±3% RH ) Measuring medium: air, pressure-less, non-aggressive Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in humidifier, dehumidifier or ventilation control. Maintenance: The humidity sensing ribbon is maintenance-free in clean air. Air containing solvent can cause measuring errors and failure, depending on the type and concentration. Deposits such as resin aerosols, lacquer aerosols, smokes, which eventually form a water-repellent film are harmful for the measuring element. Temperature measuring element: Bimetal strip Temperature adjustment range: 5-35°C Differential: 0.6+/-0.3°C Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in heating or cooling applications Options: • On Off switch • Thermal anticipator, that provides thermal differential reduction (Needs Neutral+ Line power supply, 230 or 24V) • Remote set point reduction (Needs Neutral+ Line power supply, 230 or 24V) • Temperature printings in °F Connection: screw terminal connection block for 1.5mm² wires, max torque 0.5Nm Mounting: wall mounting, with 2 screws dia 4 mm max, distance 100 x 50 mm.
    [Show full text]
  • Installation, Setup & Troubleshooting Supplement
    EconoMi$er X F a c t o r y --- I n s t a l l e d O p t i o n Low Leak Economizer for 2 Speed SAV (Staged Air Volume) Systems Installation, Setup & Troubleshooting Supplement This document is a supplemental installation instruction for the factory-installed EconoMi$er X (low leak economizer) option. It is to be used with the base unit Installation Instructions for 48/50TC, 50TCQ, 48/50HC, and 50HCQ 2-Stage cooling units, sizes 08 – 30. Units equipped with the EconoMi$er X option are identified by an indicator in the unit's model number (see the unit's nameplate). Use Table 1 (on page 2) to identify whether or not a given unit is equipped with the factory-installed EconoMi$er X. NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS SAFETY CONSIDERATIONS.................... 1 Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical GENERAL.................................... 2 shock or other conditions which may cause personal injury Identifying Factory Option...................... 2 or property damage. Consult a qualified installer, service EconoMi$er X................................ 3 agency, or your distributor or branch for information or assistance. The qualified installer or agency must use W7220 Economizer Controller................... 3 factory--authorized kits or accessories when modifying this User Interface................................ 3 product. Refer to the individual instructions packaged with Menu Structure............................... 3 the kits or accessories when installing. Checkout Tests............................... 7 Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and SETUP AND CONFIGURATION................
    [Show full text]
  • SOLAR HEATING CONTROLS by Radiantec Company
    SOLAR HEATING CONTROLS by Radiantec Company THE SOLAR CONTROL LOOP Solar Loop Control Sensors Solar Control (cover off) OPERATION- The solar loop control turns on the solar loop pump whenever solar energy is available and turns the pump off when sufficient solar energy is no longer available. (See the appendix for a detailed dis- cussion of control operation) CONTROLLER LOGIC- The solar loop control is a “differential temperature control”. It senses temperature at two locations and operates according to the difference between the temperatures at these two locations. When the temperature of the “collector” sensor is 8° F warmer, or more, than the “storage/tank” sensor, the output switch is closed. (that action turns the pump on) When the temperature of the “collector” sensor is only 4° F, or less, warmer than the “storage/tank” sensor, the output switch is opened.(That action turns the pump off ) SENSOR PLACEMENT - Place the “collector” sensor on the outlet pipe of the solar collector array and insulate well. Place the “storage” sensor on the pipe at the point where the flow from the heat exchangers come together in one pipe for return to the solar collectors. Insulate well. See page 16 of the installation manual for sensor placement details. Typical Control Setting Turn on = 8° Hi limit = 200° Optional Temperature Display SOLAR HEATING CONTROLS by Radiantec Company HEAT DUMP CONTROL Heat Dump Valve Place the heat dump valve in any hot water line and plumb to a suitable drain. Laundry room placement can be convenient. Setpoint Control Setpoint Control (cover off) OPERATION - The heat dump control lowers system temperature by automatically consuming some domestic hot water whenever excessive temperatures are detected.
    [Show full text]
  • Viega Digital Thermostat
    User Guide Viega Digital Thermostat Features ■ Compact Design ■ Digital LCD Display ■ Regulates Floor or Room Temperature ■ Optional Floor Sensor ■ Setback Function ■ On / Off Switch Specifications ■ Control: Microprocessor control ■ Accuracy: 0.1°F ■ Set Temperature Range: 41 °F - 99 °F, 0.5 °F increments This document is subject to updates. ■ Environment Range: 32 °F - 122 °F For the most current Viega technical ■ Power Supply: 24 VAC +/_ 10% literature please visit www.viega.us. 60Hz 15 W max ■ Output: TRIAC output 24 Viega products are designed to be VAC, 15 W max installed by licensed and trained ■ Optional Floor Sensor: NTC thermistor plumbing, mechanical, and electrical (10K Ohms), 10 cable professionals who are familiar with Viega ■ Floor limiting range: 41­­°F - 98.6°F products and their installation. Installation ■ Electrical Protection: Class II - IP30 by non-professionals may void Viega LLC’s 2.60" warranty. Applications The digital thermostat is ideal for individual room temperature control. A user-friendly, three- button design allows for easy adjustment of settings. The thermostat can sense either room temperature or floor temperature. Adjustable temperature setback function allows for energy savings. The thermostat can control up to four 1.22" 3.15" powerheads directly or can be connected to a zone / circulator control box. With optional floor sensor, the thermostat provides floor high or low limit function for floor protection or floor warming. UG-HC 560621 0120 Digital Thermostat (EN) 1 of 8 Viega Digital Thermostat User Guide Installation ■ Remove oval rubber plug from front of °F °C thermostat faceplate. ■ Using a small Phillips screwdriver remove screw securing thermostat faceplate to Cover Screw mounting plate.
    [Show full text]
  • Tec22x6(H)-2 Series LONWORKS® Network Thermostats with Two Outputs, Dehumidification Capability, and Three Code No
    TEC22x6(H)-2 Series LONWORKS® Network Thermostats with Two Outputs, Dehumidification Capability, and Three Code No. LIT-12011118 Speeds of Fan Control Issued August 11, 2006 Product Bulletin Supersedes May 24, 2006 The TEC22x6(H)-2 Series Thermostats are LONWORKS® network devices that provide control of two- or four-pipe fan coils, cabinet unit heaters, or other equipment using on/off, floating, or proportional 0 to 10 VDC control input, dehumidification capability, and up to three speeds of fan control. The technologically advanced TEC22x6(H)-2 Series Thermostats feature a Building Automation System (BAS) LONWORKS network communication capability that enables remote monitoring and programmability for efficient space temperature control. Specific models are available to accommodate commercial and hospitality applications. The TEC22x6(H)-2 Series Thermostats feature an intuitive user interface with backlit display that makes setup and operation quick and easy. The thermostats also employ a unique, Proportional-Integral (PI) time-proportioning algorithm that virtually eliminates Figure 1: TEC22x6-2 Series LONWORKS temperature offset associated with traditional, Network Thermostat with Two Outputs, differential-based thermostats. Dehumidification Capability, and Three Speeds of Fan Control Table 1: Features and Benefits Features Benefits LONWORKS Network Communication Provides compatibility with a proven communication network; LONWORKS network is widely accepted by Heating, Ventilating, and Air Conditioning (HVAC) control suppliers. Integral Humidity Sensing Capability and Increases occupancy comfort by providing dehumidification. Dehumidification Capability (Dehumidification Models) Backlit Liquid Crystal Display (LCD) Offers real-time control status of the environment in easy-to-read, English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Offers additional application flexibility by providing more advanced control Control signals.
    [Show full text]
  • How to Select the Right Honeywell Thermostat for Your Comfort Zone
    Step 1: Identify your heating/cooling system Thermostats IMPORTANT: Thermostats are designed to work with specific What To Look For heating/cooling systems, so it’s essential that you know your system Be Confident With Honeywell type to avoid purchasing the wrong style. All thermostats share one common feature — a way to set the temperature. After that, every Honeywell has been inventing and perfecting thermostats Central Heat or Central Heat & Air — The most common thermostat is different in terms of accuracy, reliability, number of features, display size and since 1885 and is the number one choice of homeowners system. Can be 24V gas or oil, hot water or electric. and contractors. You can count on Honeywell products for more. Here are a few features you should consider when choosing your thermostat. superior design, engineering and efficiency. Heat Pump — Heating and air conditioning combined into one unit. Can be single- or multi-stage. Years Fireplace/Floor/Wall Furnace — Millivolt or 24V of heating systems. Superior Comfort Electric Baseboard — Convectors, fan-forced heaters, Auto Change From Heat To Cool. electric baseboards and radiant ceilings. Menu-Driven Programming. Some Automatically determines if your home 4 Programmable Periods Per Day. Here To Help programmable thermostats can be needs heating or cooling to provide maxi- Honeywell programmable thermo- difficult to program, but menu-driven mum comfort. stats allow settings for wake, leave, If you have any questions about Honeywell thermostats, Step 2: Choose your thermostat type programming guides you through the return and sleep to provide you call our toll-free consumer hotline at 1-800-468-1502 or process much like using an ATM.
    [Show full text]
  • Operating and Maintenance Manual Slope Or Flat Top Console Unit
    Operating and Maintenance Manual CHPW Slope or Flat Top Console Unit Water Source Heat Pump (WSHP) Unit Contents Welcome Welcome........................................................ 2 Congratulations on your selection of the ICE AIR Water Source Heat Consumer Safety Information/Guidelines ... 3 Pump (WSHP). The WSHP is a combination cooling and heating Components and Parts View ........................ 4 unit that provides an efficient room by room source for comfort Nomenclature ............................................... 5 conditioning of your living environment. Controls ......................................................... 6 ICE AIR WSHP Console units are built to a high standard of quality LCD Programmable Operation..................7-9 and reliability, employing commercial grade components and heavy Maintenance ..........................................10-11 duty, galvanized sheet metal casings. With proper maintenance and Troubleshooting .......................................... 12 usage, ICE AIR WSHPs should provide many years of efficient, quiet Warranty/Contact Information ................... 16 and trouble-free comfort. To enhance the use of your ICE AIR equipment, you will want to read and carefully follow all of the instructions contained in this Operating and Maintenance Manual. We recommend that you pay special attention to the Safety and Warning Information section at the beginning of this Manual, and to the various safety advisories throughout this Manual. Please retain this Manual for your future reference. We suggest that you keep it with other important documents and product manuals. If your unit has optional features, they will be explained in a separate instruction sheet specific to that option. On behalf of ICE AIR, and our network of distributors and dealers, we are happy to welcome you to our base of satisfied customers! We recommend that you record the following information about your ICE AIR product(s).
    [Show full text]
  • Application of Multizone Hvac Control Using Wireless Sensor Networks and Actuating Vent Registers
    APPLICATION OF MULTIZONE HVAC CONTROL USING WIRELESS SENSOR NETWORKS AND ACTUATING VENT REGISTERS William Watts Mike Koplow Andrew Redfern Paul Wright Graduate Student Graduate Student Research Associate Professor/Director Department of Mechanical Engineering, University of California, Berkeley Center for Information Technology Research in the Interest of Society, University of California, Berkeley ABSTRACT zone consists of the house area where the vents are Most residential heating, ventilating, and air fully open. Controlling the vent registers allowed conditioning (HVAC) systems are designed to treat for reduced zonification between rooms on the the home as a single zone. Single zone control same floor, and reduced stratification between the consists of one thermostat, in a central area of the upstairs and downstairs. Energy savings were house that controls the HVAC operation. In a shown when vents were closed to heat the control single zone system all of the vent registers are zones containing the bedrooms, or the office. open, distributing air into all areas of the house at once. Single zone control leads to wasted energy INTRODUCTION for two reasons – all rooms being conditioned Most residential heating, ventilating, and when they are not occupied, and conditioning air conditioning (HVAC) systems treat the house as occupied rooms, without maintaining them at a a single zone. The standard residential system is comfortable temperature for the occupants. constant air volume (CAV). This means that the Improved control of residential cooling and heating conditioned air is delivered to all vent registers in can be attained with a variable HVAC fan, duct, the house at a fixed proportion. The lack of finer and vent system.
    [Show full text]