Automatic and DDC Control Fundamentals and Energy Conservation for HVAC Equipment-Part 1
Total Page:16
File Type:pdf, Size:1020Kb
Automatic and DDC Control Fundamentals and Energy Conservation for HVAC Equipment-Part 1 1-1 Disclaimer This presentation was prepared specifically for use as college training material. It shall not be modified without the consent of the authors. This presentation represents sponsored research activities. Neither the Client nor Battelle warrants the accuracy, completeness or usefulness of the information. Reference herein to any specific commercilial pro duc t, process or serv ice by tra de names or manufacturer does not constitute an endorsement or recommendation. PNWD-SA-8834 1-2 DDC Controls and Energy Conservation for HVAC Equipment - Agenda 1. Introduction of DDC Controls Project 2. HVAC Con tro l Pr inc ip les 3. Communication Standards and Networks 4. Vendor Examples of DDC Software Programming and Operator Interfacing 5. Typical Rooftop and Central AHU HVAC Control Systems and Applications 6. System Maintenance and Service of DDC Controls 7. Avoiding Common Control Problems and Fixing the Problems 8. Calibrating and Verifying Energy Savings of the DDC Controls PNWD-SA-8834 1-3 Part 1 HVAC Control Principles 1. Intent of Battelle Pacific NW Division involvement 2. Purpose of Controls 3. Keyyp Components of Control S ystems 4. Control Loops, Open vs. Closed Loops 5. Terminology 6. The Control Cycle and Control Actions 7. The Energy Sources for C on tro l Sys tems 8. DDC Point Types PNWD-SA-8834 1-4 Part 2 Control Applications, Networks, Programming, Maintenance, and Energy Savings 1. DDC Control Applications 2. DDC Networks and Architecture 3. Communication Standards and Networks 4. Vendor Examples of DDC Software Programming and Operator Interfacing 5. System maintenance and service of DDC controls 6. Usingggy DDC controls to save energy PNWD-SA-8834 1-5 Section 1 Introduction of DDC Controls Project • Purpose of this project is to provide HVAC edtiltiltWhitSttducational materials to Washington State community colleges to educate students who have chosen or may chose career paths related to HVAC servicing and building energy management fields PNWD-SA-8834 1-6 Section 2 HVAC Control Principles The Purpose of Temperature Controls • Control systems are the “brains” of HVAC equipment to maitiintain human com for tPitt. Picture dbld below is an AHUthtAHU that serves only one zone. This type of AHU is called a single zone AHU. In the example, a temperature sensor (stat) sends a siltignal to a con tllhihdtrol panel, which sends a s iltlignal to a valve. Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-7 Section 3 Key Componen ts of a CtlControl System Include: Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-8 Sensors Modern HVAC Sensors Include: • Humidity and temperature transmitters • CO2 for indoor air quality (IAQ) utilizing ddtltiltidemand control ventilation • Power meters • Branch circuit monitors • Energy meters Courtesy Veris Industries PNWD-SA-8834 1-9 Sensors • A sensor monitors and measures a variable. The HVAC variables are temperature, humidity, flow, and pressure. Different types of signals are produced by different types of sensors. They include: –Electric sensors –Pneumatic sensors –Electronic sensors An example of a sensor is shown here. While it may appear to be a thermostat, it is a remote sensor with a remote setpoint dial. The controller is in another location. Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-10 Pneumatic Sensors/Transmitters • Pneumatic controls sensors or transmitters sense the variable and produce a 3 psig to 15 psig (pound per square inch, gauge), [20 kPa (kiloPascals) -105 kPa] signal over a particular transmitter's range. Courtesy Johnson Controls PNWD-SA-8834 1-11 Electronic Sensors Include: • Resistance sensors are resistance temperature devices (RTDs), and are used in measuring temperature. Examples are Balco elements, copper platinum, 10K thermistors, and 30K thermistors. • Voltage sensors could be used for temperature, humidity and pressure. Typical ranges are 0 to 5 Vdc (Vlt(Volts direc t curren t)1tt), 1 to 11Vd11 Vdc, an d0td 0 to 10 Vdc. • CtCurrent sensors cou ldbdfttld be used for temperature, humidity, and pressure. The typical current range is 4 to 20 mA ((p)milliamps). PNWD-SA-8834 1-12 1000Ω (Ohms) Balco PTC Electronic Temperature Sensors • The resistance outputs of a electronic Balco temperature sensor follow the diagrams below: • When 1000 ohms is measured across the Balco element, the temperature is approximately 70°F(21F (21°C). As the temperature increases, the resistance changes 2.2 ohms per 1°F (3.96 ohms per 1°C). In a Balco temperature sensor, as the ttithititemperature increases, the resistance increases propor tilltionally in a positive direction. This is known as a positive temperature coefficient (PTC) sensor. However, many temperature sensors are considere d therm is tors, an d per form as Nega tive temperature coefficients (NTC). PNWD-SA-8834 1-13 Comppparison of Common Temp Sensors Courtesy Omega Controls PNWD-SA-8834 1-14 Controllers Can Include: Electric Controls Pneumatic Controls DDC Controls Electronic Controls Courtesy Johnson, Honeywell, and Alerton Controls PNWD-SA-8834 1-15 Controllers basic principles the controller receives the input And processes an output PNWD-SA-8834 1-16 Electronic Control System Courtesy Honeywell Controls PNWD-SA-8834 1-17 Pneumatic Controller System “Branch” or Control Damper Pressure Sensor Damper Controller Operator Filter “Main” or Supply Pressure Pressure Compressor Regulator Valve Actuator Thermostat Valve Courtesy Northwest Energy Efficiency Council PNWD-SA-8834 1-18 The DDC controller receives the input from the sensor, performs a logic function, and processes an output Courtesy DDC Online Org PNWD-SA-8834 1-19 Controller Action-Direct or Reverse Illustration Courtesy Honeywell Controls PNWD-SA-8834 1-20 Controller Direct Action-Illustration Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-21 Controller Direct Action-Illustration • This relationship between the input to a controller (temperature) and its output (current) can be displayed on a graph as follows: Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-22 Controller Reverse Action-Illustration Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-23 Controller Reverse Action-Illustration • This relationship can is displayed on a graph as follows: Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-24 Controlled Devices Control Valves – two-way Control Valves Used with differential pressure (DP) sensors and VSD pump systems on primary and secondary loops – three-way (mixing or diverting) – Pressu re independent control v alv es Automatic dampers Damper operators VSDs: variable speed drives Courtesy Belimo PNWD-SA-8834 1-25 Controlled Devices Valves Diverting Valve Mixing Valve Typical Single - and Double-Seated TilThTypical Three-WMiiWay Mixing Two-Way Valves and Diverting Valves Courtesy Belimo PNWD-SA-8834 1-26 The Present Control Systems Use control valves that are: •Pressure independent control valves •No Cv required, reduced pumping costs, higher efficiency, easy to balance. Courtesy Flow Control Valves PNWD-SA-8834 1-27 Examples of 2-Way and 3-Way Control Valves Northwest Energy Efficiency Council PNWD-SA-8834 1-28 Dampers: Types, Actuators, and Characteristics – Economizers on many central AHUs are custom o rde red fo r t he job spec ific requirements – Economizers on packaged RTUs are normally ordered as an option with the package – Control Dampers Can Be Either: PlllParallel or oppose ddd dampers Parallel Blade Opposed Blade PNWD-SA-8834 1-29 Economizer Damper Actuator Types are either: Pneumatic Electric Electronic PNWD-SA-8834 1-30 Economizer Damper Actuators will have either direct connect actuators bolted directly to the damper or they will be installed with a shaft and linkage arrangement (more prone to fail) Direct Connect Actuator Damper Connected to Actuator Via Shaft and Coupling PNWD-SA-8834 1-31 Parallel Blade Damper Characteristics have poor linear control Courtesy T.A. & Co. PNWD-SA-8834 1-32 Opposed Damper Characteristics have better linear control Courtesy T.A. & Co. PNWD-SA-8834 1-33 Damppyer Actuators can be Controlled by : • Voltage (0-10Vdc or 2-10Vdc) • Current (4-20mA) • Floati ng poi nt (bi nary pu lse to open or c lose ) • PWM-pulse width modulated • Resistance (0-135 ohms) Example of analog control using 4-20mA or 2-10Vdc Courtesy Belimo PNWD-SA-8834 1-34 Electronic Variable Frequency D r ives (VSD s ) •Vary frequency of motor to control speed •Often called VSDs , VFDs , or ASDs PNWD-SA-8834 1-35 DDC control systems have variable f()frequency drives (VFDs) as standard equipment on: • CliCooling towers • AHU’s and VAV fans • Pumps • Chillers PNWD-SA-8834 1-36 Variable Speed Drives Courtesy ABB Controls PNWD-SA-8834 1-37 Review of the Key Control Components Exercise-identify the sensors, controllers, and controlled devices Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-38 Review of the Key Control Components Exercise-connect the sensor, controller, and controlled device in the proper order. Courtesy Alerton and Belimo PNWD-SA-8834 1-39 Review of Control Action Exercise-the control drawing below has a direct acting controller, with a NO valve. Show the correct action with arrows at each component when used for cooling mode. ___________Acting Courtesy TAC Controls/Schneider Electric and Belimo PNWD-SA-8834 1-40 Review of Control Action Exercise-Circle the correct answer. Courtesy TAC Controls/Schneider Electric PNWD-SA-8834 1-41 Review of Control Action Exercise-Circle