Automated Thermostat / Humidistat Wi-Fi & Z-Wave

Total Page:16

File Type:pdf, Size:1020Kb

Automated Thermostat / Humidistat Wi-Fi & Z-Wave ™ Automated Thermostat / Humidistat Wi-Fi & Z-Wave Clare wireless digital thermostats are designed to control HVAC systems. They are offered in thermostat and thermostat / humidistat configurations, for Wi-Fi or Z-Wave. Compatible with ClareHome, the units were designed for use with networked systems where remote monitoring and/or control are desired. Wireless Communicating Thermostat • Easy Integration with ClareHome • iPad Control Technical Specifications • New All-in-One Design General • Easy Set Up • Standard or Heat Pump HVAC Systems Central HVAC systems or separate heating/ HVAC System Compatibility cooling systems; can use separate RH/RC • 128 x 64 Backlit Graphical Display transformers (split) • 6 Buttons with On Screen Labels Standard gas/electric HVAC 2-stage heating, 2-stage cooling • Optional Remote Sensors Systems: • Wall mount or mounts on single-gang junction box Heat Pump HVAC Systems: 3-stage heating, 2-stage cooling Fan system: Selectable for gas or electric heat systems Thermostat Features Heat Pump Change Over valve Selectable for change over with heat or change (reversing valve): over with cool • Local temperature display on a backlit LCD In Heat pump mode, Emergency Heat mode is Emergency Heat: • Set point display and control directly selectable from the thermostat • System Mode (Off, Auto Changeover, Heat, Cool) Compressor: Short cycle protection delay – Adjustable Automatic heating and cooling changeover, • Fan Mode display and control (Auto, Manual On) Features • On-screen setup of HVAC Type, Fan Type, Change over fan Cycler feature type for Heat Pump systems, and sensor calibration Remote Sensors • On-screen Wi-Fi Network set up Indoor 1 - Can replace internal sensor or provide • Degrees Fahrenheit or Celsius Modes averaging Outdoor 1 • Compatible with the majority of HVAC systems Technical Specifications Humidistat Features Wiring Requirements 18 AWG Uses standard thermostat connections (C, R, W1, Wiring Requirements • Adjustable humidity setpoints for humidifier control W2, Y1, Y2, G) 24VAC Note: Requires both R and C wires from output Power Requirements the HVAC System Dimensions 5”x3”x3/4” Ordering Information CH-THSTAT-W Wi-Fi Thermostat/Humidistat CH-THSTAT-Z Z-Wave Thermostat/Humidistat Optional Accessories CH-RCS-3 Remote external sensor Clare Controls is a provider of solutions that streamline the integration, maintenance and monitoring of sophisticated home automation systems. Clare products are deployed locally in customer sites and administered remotely via cloud-based ™ technologies that maximize dealer efficiency while providing unprecedented customer control. For more information, visit http://www.clarecontrols.com. 7519 Pennsylvania Avenue, Suite 104, Sarasota FL 34243 | Main: 941.328.3991 | Fax: 941.870.9646 | Doc ID: 2014-02-168-04 .
Recommended publications
  • Installation Guide
    Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/Support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International) Compatible systems ecobee3 works with most centralized residential heating and cooling systems. Heating: up to 2 stages Cooling: up to 2 stages Heat pumps: 1 or 2 stages + up to 2 stages auxiliary heat Accessories: Dehumidifier, humidifier or ventilation device 3 Items included in box A ecobee3 thermostat with D Large trim plate back plate and trim plate E Screws and drywall plugs B Remote Sensor and stand F Information booklets C Power Extender Kit G Double-sided adhesives (optional) A B C wire labels Installation Guide Quick Start Guide D E F G 4 Items you’ll need A Phillips screwdriver B Drill for mounting anchors with 3⁄₁₆ inch drill bit A B Tip: Review all the instructions before you start to ensure that there are no surprises during installation. Tip: For accurate temperature readings, install your ecobee3 in a conditioned space, on an interior wall, and away from direct heat sources. 5 Overview of steps Installing your ecobee3 home climate system is easy. Just follow these steps and you’ll be done before you know it. Step 1 Power off your HVAC system page 8 Before doing anything else, power off your system. Step 2 Label the wires page 9 Label each wire with the provided stickers. Step 3 Install Power Extender Kit page 11 The PEK is not required for all installs.
    [Show full text]
  • DOAS Enthalpy Wheel (EW) Issues
    DOAS Enthalpy Wheel (EW) Issues: 1. Is it required for DOAS? Yes for all practical purposes in the USA. Both ASHRAE Std. 90.1 and ASHRAE’s new Standard for the Design Of High Performance Green Buildings (189.1) require a 60% effective total energy recovery (TER) device for even the smallest systems in the moist USA--located primarily east of the continental divide as illustrated below: 2. Life and durability. The following link provides useful information, particularly concerning the life expectancy. http://www.thermotech-usa.com/tech_heatwheel 3. Purge, a basic description of how it works is at the following link: http://www.thermotech-usa.com/tech_purge . The presence of the purge requires an increase in air flow beyond the desired supply air delivery requirement, increasing fan energy use. Therefore unless absolutely needed for air quality reasons (most all-air systems in commercial facilities recirculate up to 80% of the air—so what is a few percent recirculation at the EW going to hurt) purge should be avoided. 4. Seal leakage is an equally important issue. Like purge, seal leakage should be minimized for fan energy savings as well. This requires wheels with tough wear resistant and very planar faces. And the seals must be very close fitting. 5. Dirty Socks Odor Syndrome: Published references for EW occurrences are not readily available at this time. However the syndrome occurrences have only been reported where a silica gel desiccant on non-aluminum matrix substrate EW is used. There have not been reports of this syndrome problem for applications where a molecular sieve (zeolite) desiccant on an aluminum substrate EW is used.
    [Show full text]
  • Cd60 Dehumidifier Specifications
    To Buy: Visit www.sylvane.com or call (800) 934-9194 For Product Support: Contact Ebac USA at (757) 873 6800 CD60 DEHUMIDIFIER SPECIFICATIONS Specifications CD60 Features CD60 Model No. 10264FR-US Model No. 10264FR-US Height 17” (432mm) On/Off Control Width 20” (514mm) Electronic Defrost Control Depth 14” (356mm) Compressor Type Rotary Weight 80 lbs (36kg) Fitted Mains Plug Voltage 110 V Free Standing Adjustable Feet Phase 1 Remote Humidistat Frequency 60 Hz Adjustable Control Humidistat Current 7 A Hot Gas Defrost System Power 880W Hours Run Meter Airflow 360cfm (608m3/hr) High Capacity Condensate Pump Noise Level 57 dba Quick Disconnect Hose Coupling Refrigerant R407c 25’ Length of PVC Drain Hose Effective Volume 8,369 cu.ft (237m3) Epoxy Powder Coating Typical Extraction 56 ppd Minimum Operating Temperature 33°F (1°C) Maximum Operating Temperature 95°F (35°C) APPLICATION The EIPL CD60 commercial / industrial dehumidifier was designed to provide energy efficient humidity control in a wide range of applications including offices, laboratories, apartments, storage areas, restaurants, bars, museums, locker rooms, computer, telecommunication rooms and basements. It is a quiet, high efficiency, high capacity unit designed to suit your HVAC needs. KEY DESIGN FEATURES • Adjustable control humidistat to maintain the level of dryness • A convenient drain point for condensate collection of hose attachment • EIP’s unique “Hot Gas” defrosting feature which automatically melts away frost buildup providing effective operation at low ambient temperatures • Rugged, epoxy powder-coated steel chassis and housing. • Hours run meter • Simplicity of installation and operation with a standard 115V plug • Extra long power cord.
    [Show full text]
  • Icomfort S30 Smart Thermostat Installation and Setup Guide
    iComfort® S30 Smart Thermostat Installation and Setup Guide Color Touchscreen Programmable Wi-Fi Communicating Thermostat (12U67) 507536-02 5/2017 Supersedes 10/2016 Software Version 3.2 TABLE OF CONTENTS SHIPPING AND PACKING LIST ............................................. 3 Mag-Mount....................................................... 33 GENERAL ................................................................. 3 Add / Remove Equipment........................................... 33 INSTALLING CONTROL SYSTEM COMPONENTS ............................. 4 Reset ............................................................ 33 Smart Hub Installation................................................... 4 Notifications ........................................................... 33 Mag-Mount Installation.................................................. 5 Tests ................................................................. 33 HD Display External Components......................................... 6 Diagnostics ............................................................ 33 HD Display Installation.................................................. 6 Installation Report...................................................... 33 WIRING FOR CONTROL SYSTEM COMPONENTS............................. 7 Information ............................................................ 34 CONFIGURATING HEAT SECTIONS ON AIR HANDLER CONTROL.............. 12 Dealer — Information............................................... 34 SMART HUB OPERATIONS................................................
    [Show full text]
  • Model 70007000
    M ModelModel 70007000 Installation/Operating Instructions # 010921025 2 Model 7000 Flow Through Humidifier FREQUENTLY ASKED QUESTIONS your furnace is running and in heating mode. 24 hours of humidifier operation may take 3 days to complete. Question: Why use a flow-through style humidifier rather Question: How much water does this humidifier use? than a drum style humidifier? Answer: This humidifier incorporates a restrictor which Answer: This will depend on several factors including size of meters the amount of water supplied to the unit. In the home, style of furnace, and size of ducting; as well as personal average home the unit will use totally 56 US gallons (47 preference. However in order to use this model flow through Imperial gallons, 212 Litres) of water per 24 hours of you will require at least 10" wide ducting where as our drum operation. styles will fit on 8" ducting. Comment: As mentioned above 24 hours of operation refers Comment: Flow-through and rotating-drum style evaporative to humidifier operation, the 24 hours operating time may take furnace humidifiers will safely and efficiently humidify 90% of 3 days to complete. When Compared to the water consumed homes which use forced air heating. As a manufacturer of during the average shower (3 to 5 gallons per minute) the total both styles there are pro’s and con’s to be considered when amount of water consumed to humidify your home is not that choosing a type of humidifier. A drum style humidifier is much. typically 100% efficient in its use of water, meaning all the water it uses will be delivered to the air.
    [Show full text]
  • Dodge Cummins Coolant Bypass
    FPE-2018-06 SUBJECT: DODGE CUMMINS COOLANT BYPASS KIT November, 2020 Page 1 of 6 FITMENT: 2003–2007 Dodge Cummins Manual Transmission Only 2007.5-2018 Dodge Cummins Manual and Automatic Transmissions KIT P/N: FPE-CLNTBYPS-CUMMINS-MAN, FPE-CLNTBYPS-CUMMINS-6.7 ESTIMATED INSTALLATION TIME: 2-3 Hours TOOLS REQUIRED: 16mm ratcheting wrench, 10mm socket, 8mm socket, 6mm Allen, 1” wrench, hammer, 5-gallon clean drain pan, 36” pry bar, Scotch-Brite TM pad (included in kit). KIT CONTENTS: Item Description Qty 1 Coolant bypass hose 1 2 Coolant bypass thermostat housing 1 and O-ring 3 Thermostat riser block and O-ring 1 3 4 4 Coolant bypass hose riser bracket 2 2 5 M8 x 1.25, 20mm socket head cap 2 screw 7 6 6 M6 x 1.00 x 60mm flange head bolt 3 5 7 M12 x 1.75, 40mm flange head bolt 2 8 Scotch-Brite TM pad (not pictured) 1 1 WARNINGS: • Use of this product may void or nullify the vehicle’s factory warranty. • User assumes sole responsibility for the safe & proper use of the vehicle at all times. • The purchaser and end user releases, indemnifies, discharges, and holds harmless Fleece Performance Engineering, Inc. from any and all claims, damages, causes of action, injuries, or expenses resulting from or relating to the use or installation of this product that is in violation of the terms and conditions on this page, the product disclaimer, and/or the product installation instructions. Fleece Performance Engineering, Inc. will not be liable for any direct, indirect, consequential, exemplary, punitive, statutory, or incidental damages or fines cause by the use or installation of this product.
    [Show full text]
  • And Tec220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers
    TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Code No. LIT-12011611 Technical Bulletin Issued February 8, 2010 Network Variables (NVs) and Configuration Parameters (CPs) List. 3 Network Variable Inputs (NVIs) Table . 8 Network Variable Outputs (NVOs) Table . 10 Configuration Properties (CPs) . 13 Space Comfort Controller Object . 18 Commissioning the Thermostat Using a LONWORKS Network Configuration Tool . 18 Service Pin . 19 TEC22xx-4 Configuration Plug-in. 19 Installing the Plug-in. 19 Registering the Plug-in. 20 Using LN Browser to Display NVs, NCIs, and CPs . 22 Running the Plug-in . 27 Heating - Cooling Tab . 31 Hardware Tab . 32 General Tab . 33 Model Tab . 34 Scheduler Tab . 36 Network Tab . 38 About Tab . 39 Adding a Thermostat to the Network Automation Engine (NAE) . 39 LONWORKS Thermostat Controller Mapping . 40 Preparation . 40 Troubleshooting Guide . 40 Technical Specifications . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS Network Staged Thermostat Controllers . 43 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged 1 Thermostat Controllers Technical Bulletin 2 TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin TEC226x-4(+PIR) and TEC220x-4(+PIR) Series LONWORKS® Network Staged Thermostat Controllers Technical Bulletin Network Variables (NVs) and Configuration Parameters (CPs) List Table 1 shows the NVs and CPs for the TEC226x-4(+PIR) and TEC220x-4(+PIR) Series Thermostat Controllers. Each Network Variable Input (NVI), Network Variable Output (NVO), and Network Configuration Input (NCI) has a reference number as defined in the XIF Resource File, and some objects have a subcategory number.
    [Show full text]
  • Guide for Air Conditioning, Refrigeration, and Help the Student
    DOCUMENT RESUME ED 251 645 CE 040 232 AUTHOR Henderson, William Edward, Jr., Ed. TITLE Art::culated, Performance-Based Instruction Objectives Guide for Air Conditioning, Refrigeration, and Heating. Volume II(Second Year). INSTITUTION Greenville County School District, Greenville, S.C.; Greenville Technical Coll., S. PUB DATE Oct 84 NOTE 374p.; Prepared by the Articulation Program Task Force Committee for Air Conditioning, Refrigeration, and Heating. PUB TYPE Guides Clasrroom Use Guides (For Teachers) (052) EDRS PRICE MF01/PC15 Plus Postage. DESCRIPTO. *Air Conditioning; Behavioral Objectives; Competency Based Education; Curriculum Guides; *Equipment Maintenance; Fuels; Jrade 12; *Heating; High Schools; Job Skills; Le.,zning Activities; *Refrigeration; Secondary Education; Solar Energy; Trade and Industrial Education; Units of Study; *Ventilation ABSTRACT This articulation guide contains 17 units of instruction for the second year of a two-year vocational program designed to prepare the high school graduate to install, maintain, and repair various types of residential and commercial heating, air conditioning, and refrigeration equipment. The units are designed to help the student to expand and apply the basic knowledge already mastered and to learn new principles and techniques and to prepare him/her for entry-level work as an apprentice. The seventeen units cover aid conditioning calculations (psychrometrics,residential heat loss and heat gain, duct design and sizing and air treatment); troubleshooting and servicing residential air conditioners; commercial refrigeration; commercial air conditioning; heating systems (electrical resistance heating, heat pumps, gas heating, oil heating, hydronics, solar heating systems); automotive air conditioner maintenance/repair; estimating and planning heating, ventilation, and air conditioning jobs; customer relations; and shop projects.
    [Show full text]
  • Room Humidistat and Thermostat Combination, Wall Mounting, For
    Room humidistat and thermostat combination, wall mounting, for swimming pools areas and air conditioning Type Q4 DIMENSIONS MAIN FEATURES Main Application: This device is a combination of a humidistat and a room thermostat. It is especially suited for use in air conditioning control of indoor swimming-pool halls.His aesthetics and small size housing (122x70x31mm) allows mounting in most of these applications, but must be protected from splashing water, and used only in ambient air free of chemical contamination or corrosive ingredients. It is designed to turn on heating or cooling, ventilation, humidifiers, dehumidifiers, and heat pumps. It must be vertically wall mounted in a naturally ventilated area Humidity sensing element: hygroscopic polymer film with special treatment, produced by Ultimheat, ensuring a fast response, long life and high stability Humidity setting range: 35 to 95% RH Humidity measuring accuracy: ±5% RH Differential at 50% RH: 8% RH (±3% RH ) Measuring medium: air, pressure-less, non-aggressive Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in humidifier, dehumidifier or ventilation control. Maintenance: The humidity sensing ribbon is maintenance-free in clean air. Air containing solvent can cause measuring errors and failure, depending on the type and concentration. Deposits such as resin aerosols, lacquer aerosols, smokes, which eventually form a water-repellent film are harmful for the measuring element. Temperature measuring element: Bimetal strip Temperature adjustment range: 5-35°C Differential: 0.6+/-0.3°C Electrical contact: silver contacts, SPDT, 5A 250V, res. For use in heating or cooling applications Options: • On Off switch • Thermal anticipator, that provides thermal differential reduction (Needs Neutral+ Line power supply, 230 or 24V) • Remote set point reduction (Needs Neutral+ Line power supply, 230 or 24V) • Temperature printings in °F Connection: screw terminal connection block for 1.5mm² wires, max torque 0.5Nm Mounting: wall mounting, with 2 screws dia 4 mm max, distance 100 x 50 mm.
    [Show full text]
  • Installation, Setup & Troubleshooting Supplement
    EconoMi$er X F a c t o r y --- I n s t a l l e d O p t i o n Low Leak Economizer for 2 Speed SAV (Staged Air Volume) Systems Installation, Setup & Troubleshooting Supplement This document is a supplemental installation instruction for the factory-installed EconoMi$er X (low leak economizer) option. It is to be used with the base unit Installation Instructions for 48/50TC, 50TCQ, 48/50HC, and 50HCQ 2-Stage cooling units, sizes 08 – 30. Units equipped with the EconoMi$er X option are identified by an indicator in the unit's model number (see the unit's nameplate). Use Table 1 (on page 2) to identify whether or not a given unit is equipped with the factory-installed EconoMi$er X. NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS SAFETY CONSIDERATIONS SAFETY CONSIDERATIONS.................... 1 Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical GENERAL.................................... 2 shock or other conditions which may cause personal injury Identifying Factory Option...................... 2 or property damage. Consult a qualified installer, service EconoMi$er X................................ 3 agency, or your distributor or branch for information or assistance. The qualified installer or agency must use W7220 Economizer Controller................... 3 factory--authorized kits or accessories when modifying this User Interface................................ 3 product. Refer to the individual instructions packaged with Menu Structure............................... 3 the kits or accessories when installing. Checkout Tests............................... 7 Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and SETUP AND CONFIGURATION................
    [Show full text]
  • SOLAR HEATING CONTROLS by Radiantec Company
    SOLAR HEATING CONTROLS by Radiantec Company THE SOLAR CONTROL LOOP Solar Loop Control Sensors Solar Control (cover off) OPERATION- The solar loop control turns on the solar loop pump whenever solar energy is available and turns the pump off when sufficient solar energy is no longer available. (See the appendix for a detailed dis- cussion of control operation) CONTROLLER LOGIC- The solar loop control is a “differential temperature control”. It senses temperature at two locations and operates according to the difference between the temperatures at these two locations. When the temperature of the “collector” sensor is 8° F warmer, or more, than the “storage/tank” sensor, the output switch is closed. (that action turns the pump on) When the temperature of the “collector” sensor is only 4° F, or less, warmer than the “storage/tank” sensor, the output switch is opened.(That action turns the pump off ) SENSOR PLACEMENT - Place the “collector” sensor on the outlet pipe of the solar collector array and insulate well. Place the “storage” sensor on the pipe at the point where the flow from the heat exchangers come together in one pipe for return to the solar collectors. Insulate well. See page 16 of the installation manual for sensor placement details. Typical Control Setting Turn on = 8° Hi limit = 200° Optional Temperature Display SOLAR HEATING CONTROLS by Radiantec Company HEAT DUMP CONTROL Heat Dump Valve Place the heat dump valve in any hot water line and plumb to a suitable drain. Laundry room placement can be convenient. Setpoint Control Setpoint Control (cover off) OPERATION - The heat dump control lowers system temperature by automatically consuming some domestic hot water whenever excessive temperatures are detected.
    [Show full text]
  • Viega Digital Thermostat
    User Guide Viega Digital Thermostat Features ■ Compact Design ■ Digital LCD Display ■ Regulates Floor or Room Temperature ■ Optional Floor Sensor ■ Setback Function ■ On / Off Switch Specifications ■ Control: Microprocessor control ■ Accuracy: 0.1°F ■ Set Temperature Range: 41 °F - 99 °F, 0.5 °F increments This document is subject to updates. ■ Environment Range: 32 °F - 122 °F For the most current Viega technical ■ Power Supply: 24 VAC +/_ 10% literature please visit www.viega.us. 60Hz 15 W max ■ Output: TRIAC output 24 Viega products are designed to be VAC, 15 W max installed by licensed and trained ■ Optional Floor Sensor: NTC thermistor plumbing, mechanical, and electrical (10K Ohms), 10 cable professionals who are familiar with Viega ■ Floor limiting range: 41­­°F - 98.6°F products and their installation. Installation ■ Electrical Protection: Class II - IP30 by non-professionals may void Viega LLC’s 2.60" warranty. Applications The digital thermostat is ideal for individual room temperature control. A user-friendly, three- button design allows for easy adjustment of settings. The thermostat can sense either room temperature or floor temperature. Adjustable temperature setback function allows for energy savings. The thermostat can control up to four 1.22" 3.15" powerheads directly or can be connected to a zone / circulator control box. With optional floor sensor, the thermostat provides floor high or low limit function for floor protection or floor warming. UG-HC 560621 0120 Digital Thermostat (EN) 1 of 8 Viega Digital Thermostat User Guide Installation ■ Remove oval rubber plug from front of °F °C thermostat faceplate. ■ Using a small Phillips screwdriver remove screw securing thermostat faceplate to Cover Screw mounting plate.
    [Show full text]