Scalability of VM Provisioning Systems
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
IBM VM Recovery Manager DR for Power Systems Version 1.5: Deployment Guide Overview for IBM VM Recovery Manager DR for Power Systems
IBM VM Recovery Manager DR for Power Systems Version 1.5 Deployment Guide IBM Note Before using this information and the product it supports, read the information in “Notices” on page 195. This edition applies to IBM® VM Recovery Manager DR for Power Systems Version 1.5 and to all subsequent releases and modifications until otherwise indicated in new editions. © Copyright International Business Machines Corporation 2020, 2021. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents About this document............................................................................................vii Highlighting.................................................................................................................................................vii Case-sensitivity in VM Recovery Manager DR............................................................................................vii ISO 9000....................................................................................................................................................viii Overview...............................................................................................................1 Concepts...............................................................................................................5 KSYS............................................................................................................................................................. 5 HMC............................................................................................................................................................. -
Flexible Lustre Management
Flexible Lustre management Making less work for Admins ORNL is managed by UT-Battelle for the US Department of Energy How do we know Lustre condition today • Polling proc / sysfs files – The knocking on the door model – Parse stats, rpc info, etc for performance deviations. • Constant collection of debug logs – Heavy parsing for common problems. • The death of a node – Have to examine kdumps and /or lustre dump Origins of a new approach • Requirements for Linux kernel integration. – No more proc usage – Migration to sysfs and debugfs – Used to configure your file system. – Started in lustre 2.9 and still on going. • Two ways to configure your file system. – On MGS server run lctl conf_param … • Directly accessed proc seq_files. – On MSG server run lctl set_param –P • Originally used an upcall to lctl for configuration • Introduced in Lustre 2.4 but was broken until lustre 2.12 (LU-7004) – Configuring file system works transparently before and after sysfs migration. Changes introduced with sysfs / debugfs migration • sysfs has a one item per file rule. • Complex proc files moved to debugfs • Moving to debugfs introduced permission problems – Only debugging files should be their. – Both debugfs and procfs have scaling issues. • Moving to sysfs introduced the ability to send uevents – Item of most interest from LUG 2018 Linux Lustre client talk. – Both lctl conf_param and lctl set_param –P use this approach • lctl conf_param can set sysfs attributes without uevents. See class_modify_config() – We get life cycle events for free – udev is now involved. What do we get by using udev ? • Under the hood – uevents are collect by systemd and then processed by udev rules – /etc/udev/rules.d/99-lustre.rules – SUBSYSTEM=="lustre", ACTION=="change", ENV{PARAM}=="?*", RUN+="/usr/sbin/lctl set_param '$env{PARAM}=$env{SETTING}’” • You can create your own udev rule – http://reactivated.net/writing_udev_rules.html – /lib/udev/rules.d/* for examples – Add udev_log="debug” to /etc/udev.conf if you have problems • Using systemd for long task. -
Version 7.8-Systemd
Linux From Scratch Version 7.8-systemd Created by Gerard Beekmans Edited by Douglas R. Reno Linux From Scratch: Version 7.8-systemd by Created by Gerard Beekmans and Edited by Douglas R. Reno Copyright © 1999-2015 Gerard Beekmans Copyright © 1999-2015, Gerard Beekmans All rights reserved. This book is licensed under a Creative Commons License. Computer instructions may be extracted from the book under the MIT License. Linux® is a registered trademark of Linus Torvalds. Linux From Scratch - Version 7.8-systemd Table of Contents Preface .......................................................................................................................................................................... vii i. Foreword ............................................................................................................................................................. vii ii. Audience ............................................................................................................................................................ vii iii. LFS Target Architectures ................................................................................................................................ viii iv. LFS and Standards ............................................................................................................................................ ix v. Rationale for Packages in the Book .................................................................................................................... x vi. Prerequisites -
Facility/370: Introduction
File No. S370-20 Order No. GC20-1800=9 IDl\n \/:u+ •• ".1 I\n"n"': ..... ft IDIVI V IIlUQI .Via"'lllIlv Facility/370: Systems Introduction Release 6 PLC 4 This publication introduces VM/370, and is intended for anyone who is interested in VM/370. However, the reader should have a basic understanding of I BM data processing. VM/370 (Virtual Machine Facility/370) is a system control program (SCP) that tailors the resources and capabilities of a single System/370 computer to provide concurrent users their one unique (virtual) machine. VM/370 consists of a Control Program (CP), which manages the real computer, a Conversational Monitor System (CMS), which is a general-purpose conversational time-sharing system that executes in a virtual machine, a Remote Spooling Communications Subsystem (RSCS), which spools files to and from geographically remote locations, and a Interactive Problem Control System (I PCS), which provides problem analysis and management faci I ities. The first section of the publication is an introduction; it describes what VM/370 can do. The second, third, fourth, and fifth sections describe the Control Program, Conversational Monitor System, Remote Spooling Communications Subsystem, and Interactive Problem Control System respectively. The appendixes include information about VM/370 publication-to-audience relationship and VM/370-related publications for CMS users. , This publication is a prerequisite for the VM/370 system library. --...- --- ---.-- ------- ------ --..- --------- -~-y- Page of GC20-1800-9 As Updated Aug 1, 1979 by TNL GN25-0U89 ~b Edition (Karch 1919) This edition (GC20-1800-~ together with Technical Newsletter GN25-0489. dated August 1, 1919, applies to Release 6 PLC 4 (Program Level Change) of IBM Virtual Machine Facility/310 and to all subsequent releases until otherwise indicated in new editions or Technical Newsletters. -
Z/OS ♦ Z Machines Hardware ♦ Numbers and Numeric Terms ♦ the Road to Z/OS ♦ Z/OS.E ♦ Z/OS Futures ♦ Language Environment ♦ Current Compilers ♦ UNIX System Services
Mainframes The Future of Mainframes Is Now ♦ z/Architecture ♦ z/OS ♦ z Machines Hardware ♦ Numbers and Numeric Terms ♦ The Road to z/OS ♦ z/OS.e ♦ z/OS Futures ♦ Language Environment ♦ Current Compilers ♦ UNIX System Services by Steve Comstock The Trainer’s Friend, Inc. http://www.trainersfriend.com 800-993-8716 [email protected] Copyright © 2002 by Steven H. Comstock 1 Mainframes z/Architecture z/Architecture ❐ The IBM 64-bit mainframe has been named "z/Architecture" to contrast it to earlier mainframe hardware architectures ♦ S/360 ♦ S/370 ♦ 370-XA ♦ ESA/370 ♦ ESA/390 ❐ Although there is a clear continuity, z/Architecture also brings significant changes... ♦ 64-bit General Purpose Registers - so 64-bit integers and 64-bit addresses ♦ 64-bit Control Registers ♦ 128-bit PSW ♦ Tri-modal addressing (24-bit, 31-bit, 64-bit) ♦ Over 140 new instructions, including instructions to work with ASCII and UNICODE strings Copyright © 2002 by Steven H. Comstock 2 z/Architecture z/OS ❐ Although several operating systems can run on z/Architecture machines, z/OS is the premier, target OS ❐ z/OS is the successor to OS/390 ♦ The last release of OS/390 was V2R10, available 9/2000 ♦ The first release of z/OS was V1R1, available 3/2001 ❐ z/OS can also run on G5/G6 and MP3000 series machines ♦ But only in 31-bit or 24-bit mode ❐ Note these terms: ♦ The Line - the 16MiB address limit of MVS ♦ The Bar - the 2GiB limit of OS/390 ❐ For some perspective, realize that 16EiB is... ♦ 8 billion times 2GiB ♦ 1 trillion times 16MiB ❐ The current release of z/OS is V1R4; V1R5 is scheduled for 1Q2004 Copyright © 2002 by Steven H. -
Cisco UCS C240 M4 SFF Rack Server Spec Sheet
This Product has been discontinued Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV E.20 MARCH 23, 2021 WWW.CISCO.COM CONTENTS OVERVIEW . 5 DETAILED VIEWS . 6 Chassis Front View . .6 Chassis Rear View . .9 BASE SERVER STANDARD CAPABILITIES and FEATURES . 11 CONFIGURING the SERVER . 15 STEP 1 VERIFY SERVER SKU . 16 STEP 2 SELECT RISER CARDS (OPTIONAL) . 17 STEP 3 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . 18 STEP 4 SELECT CPU(s) . 19 STEP 5 SELECT MEMORY . 21 STEP 6 SELECT RAID CONTROLLERS . 27 RAID Controller Options (internal HDD/SSD support) . 27 Embedded Software RAID . 27 Cisco 12G SAS Modular RAID Controller . 27 SAS HBA (internal HDD/SSD/JBOD support) . 27 SAS HBA (external JBOD support) . 27 RAID Volumes and Groups . 28 STEP 7 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . 39 STEP 8 SELECT SED HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . 45 STEP 9 SELECT PCIe OPTION CARD(s) . 48 STEP 10 ORDER OPTIONAL NETWORK CARD ACCESSORIES . 53 STEP 11 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL) . 58 STEP 12 ORDER POWER SUPPLY . 61 STEP 13 SELECT AC POWER CORD(s) . 62 STEP 14 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 65 STEP 15 SELECT NIC MODE (OPTIONAL) . 66 STEP 16 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . 67 STEP 17 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . 69 STEP 18 ORDER OPTIONAL USB 3.0 DRIVE . -
IBM Virtual Machine Facility/370 : Systems Introduction
GC20-1800-0 IBM Virtual Machine Facility/370 : Systems Introduction The IBM Virtual Machine Facility/370 (VM/370) is a System Control Program (SCP) that has been designed specifically for the IBM System/370. VM/370 manages the IBM System/370 in such a way that mUltiple remote terminal users appear to have a dedicated computing system at their disposal. Within this "virtual machine" the user may run the operaHng system of his choice, subject to the restrictions noted in "Appendix C: VM/370 Restrictions" of this manual. The design of VM/370 is based on the IBM Control Program-67/Cam bridge Monitor System (CP-67/CMS) which is executed on an IBM System/360 Model 67. The Conversational Monitor System (CMS) is the major subsystem ofVM/370. CMS provides problem solving and program development services to the user, as well as supporting facilities for a remote user who chooses to run some other operating system in his virtual machine. This manual provides introductory information about the facilities provided by VM/370, and defines the min imum equipment configuration necessary for execution. Preface This manual provides introductory information on the IBM Virtual Machine Facility/370 (VM/370) and its associated subsystem, the Conversational Monitor Sys tem (CMS), as well as an overview of the purpose and functions of VM/370. It is assumed that the user has a prior knowledge of virtual storage concepts as implemented on the IBM System/370 via dynamic address translation. The reader is referred to Part I of the student text publication Introduction to Virtual Storage in System/370, Order No. -
Microkernel Vs
1 VIRTUALIZATION: IBM VM/370 AND XEN CS6410 Hakim Weatherspoon IBM VM/370 Robert Jay Creasy (1939-2005) Project leader of the first full virtualization hypervisor: IBM CP-40, a core component in the VM system The first VM system: VM/370 Virtual Machine: Origin 3 IBM CP/CMS CP-40 CP-67 VM/370 Why Virtualize 4 Underutilized machines Easier to debug and monitor OS Portability Isolation The cloud (e.g. Amazon EC2, Google Compute Engine, Microsoft Azure) IBM VM/370 Specialized Conversation Mainstream VM al Monitor OS (MVS, Another Virtual subsystem System DOS/VSE copy of VM machines (RSCS, RACF, (CMS) etc.) GCS) Hypervisor Control Program (CP) Hardware System/370 IBM VM/370 Technology: trap-and-emulate Problem Application Privileged Kernel Trap Emulate CP Classic Virtual Machine Monitor (VMM) 7 Virtualization: rejuvenation 1960’s: first track of virtualization Time and resource sharing on expensive mainframes IBM VM/370 Late 1970’s and early 1980’s: became unpopular Cheap hardware and multiprocessing OS Late 1990’s: became popular again Wide variety of OS and hardware configurations VMWare Since 2000: hot and important Cloud computing Docker containers Full Virtualization 9 Complete simulation of underlying hardware Unmodified guest OS Trap and simulate privileged instruction Was not supported by x86 (Not true anymore, Intel VT-x) Guest OS can’t see real resources Paravirtualization 10 Similar but not identical to hardware Modifications to guest OS Hypercall Guest OS registers handlers Improved performance VMware ESX Server 11 Full virtualization Dynamically rewrite privileged instructions Ballooning Content-based page sharing Denali 12 Paravirtualization 1000s of VMs Security & performance isolation Did not support mainstream OSes VM uses single-user single address space 13 Xen and the Art of Virtualization Xen 14 University of Cambridge, MS Research Cambridge XenSource, Inc. -
IIP (System Z9 Integrated Information Processor) Computer CEC (Central Electronics Complex) Server
IBM System z z/VM Basics Arwed Tschoeke Systems Architect [email protected] © 2009 IBM Corporation © 2008 IBM Corporation Introduction We'll explain basic concepts of System z: – Terminology – Processors – Memory – I/O – Networking We'll see that z/VM virtualizes a System z machine: – Virtual processors – Virtual memory – … and so on Where appropriate, we'll compare or contrast: – PR/SM or LPAR – z/OS – Linux 2 z/VM: The Very Basics z/VM: The Very Basics 1 IBM System z © 2008 IBM Corporation System z Parts Nomenclature x86, UNIX, etc. System z Memory Storage (though we are moving toward "memory") Disk, Storage DASD – Direct Access Storage Device Processor Processor, Engine, PU (processing unit) IOP (I/O processor) CPU (central processing unit) CP (central processor) SAP (system assist processor) Specialty engines –IFL (Integrated Facility for Linux) –zAAP (System z Application Assist Processor) –zIIP (System z9 Integrated Information Processor) Computer CEC (central electronics complex) Server 3 z/VM: The Very Basics © 2008 IBM Corporation IBM System z Virtualization Genetics Over 40 years of continuous innovation in virtualization – Refined to support modern business requirements System z10 . – Exploit hardware technology for economical growth , .. ity System z9 z/VM V5 bil – LPAR, Integrated Facility for Linux, HiperSockets xi 64-Bit Fle – System z Application Assist Processors s, zSeries es VM/ESA Virtual Switch – System z Information Integration stn 9672 bu ESA Guest LANs Set Observer Ro Processors y, 9x21 ilit VM/XA Virtual Machine -
High Level Assembler for MVS & VM & VSE Programmer's Guide
IBM High Level Assembler for MVS & VM & VSE Programmer’s Guide Release 5 SC26-4941-04 IBM High Level Assembler for MVS & VM & VSE Programmer’s Guide Release 5 SC26-4941-04 Note! Before using this information and the product it supports, be sure to read the general information under “Notices” on page 422. Fifth Edition (June 2004) This edition applies to IBM High Level Assembler for MVS & VM & VSE, Release 5, Program Number 5696-234 and to any subsequent releases until otherwise indicated in new editions. Make sure you are using the correct edition for the level of the product. Order publications through your IBM representative or the IBM branch office serving your locality. Publications are not stocked at the address below. A form for reader's comments is provided at the back of this publication. If the form has been removed, address your comments to: IBM Corporation J87/D325 555 Bailey Avenue SAN JOSE, CA 95141-1003 United States of America When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you. Copyright International Business Machines Corporation 1982, 2004. All rights reserved. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Contents About this Manual .................................... xi Who Should Use this Manual .............................. xi Programming Interface Information ........................... xi Organization of this Manual ............................... xi IBM High Level Assembler for MVS & VM & VSE Publications .......... xiv Publications . xiv Softcopy Publications . xv The High Level Assembler web site ........................ -
Container and Kernel-Based Virtual Machine (KVM) Virtualization for Network Function Virtualization (NFV)
Container and Kernel-Based Virtual Machine (KVM) Virtualization for Network Function Virtualization (NFV) White Paper August 2015 Order Number: 332860-001US YouLegal Lines andmay Disclaimers not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest Intel product specifications and roadmaps. The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Copies of documents which have an order number and are referenced in this document may be obtained by calling 1-800-548-4725 or by visiting: http://www.intel.com/ design/literature.htm. Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software or service activation. Learn more at http:// www.intel.com/ or from the OEM or retailer. Results have been estimated or simulated using internal Intel analysis or architecture simulation or modeling, and provided to you for informational purposes. Any differences in your system hardware, software or configuration may affect your actual performance. For more complete information about performance and benchmark results, visit www.intel.com/benchmarks. Tests document performance of components on a particular test, in specific systems. -
IBM Powervm Virtualization Introduction and Configuration
Front cover IBM PowerVM Virtualization Introduction and Configuration Understand PowerVM features and capabilities Plan, implement, and set up PowerVM virtualization Updated to include new POWER7 technologies Mel Cordero Lúcio Correia Hai Lin Vamshikrishna Thatikonda Rodrigo Xavier ibm.com/redbooks International Technical Support Organization IBM PowerVM Virtualization Introduction and Configuration June 2013 SG24-7940-05 Note: Before using this information and the product it supports, read the information in “Notices” on page xxi. Sixth Edition (June 2013) This edition applies to: Version 7, Release 1 of AIX Version 7, Release 1 of IBM i Version 2, Release 2, Modification 2, Fixpack 26 of the Virtual I/O Server Version 7, Release 7, Modification 6 of the HMC Version AL730, release 95 of the POWER7 System Firmware Version AL740, release 95 of the POWER7 System Firmware © Copyright International Business Machines Corporation 2004, 2013. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Figures . xi Tables . xix Notices . xxi Trademarks . xxii Preface . xxiii Authors . xxiii Now you can become a published author, too! . xxvi Comments welcome. xxvi Stay connected to IBM Redbooks . .xxvii Summary of changes . xxix June 2013, Sixth Edition. xxix Part 1. Overview . 1 Chapter 1. PowerVM technologies. 3 1.1 The value of PowerVM . 4 1.2 What is PowerVM . 4 1.2.1 New PowerVM features . 6 1.2.2 PowerVM editions . 7 1.2.3 Activating the PowerVM feature . 12 1.3 The POWER Hypervisor . 15 1.4 Logical partitioning technologies . 17 1.4.1 Dedicated LPAR .