High Level Assembler for MVS & VM & VSE Programmer's Guide

Total Page:16

File Type:pdf, Size:1020Kb

High Level Assembler for MVS & VM & VSE Programmer's Guide IBM High Level Assembler for MVS & VM & VSE Programmer’s Guide Release 5 SC26-4941-04 IBM High Level Assembler for MVS & VM & VSE Programmer’s Guide Release 5 SC26-4941-04 Note! Before using this information and the product it supports, be sure to read the general information under “Notices” on page 422. Fifth Edition (June 2004) This edition applies to IBM High Level Assembler for MVS & VM & VSE, Release 5, Program Number 5696-234 and to any subsequent releases until otherwise indicated in new editions. Make sure you are using the correct edition for the level of the product. Order publications through your IBM representative or the IBM branch office serving your locality. Publications are not stocked at the address below. A form for reader's comments is provided at the back of this publication. If the form has been removed, address your comments to: IBM Corporation J87/D325 555 Bailey Avenue SAN JOSE, CA 95141-1003 United States of America When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you. Copyright International Business Machines Corporation 1982, 2004. All rights reserved. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Contents About this Manual .................................... xi Who Should Use this Manual .............................. xi Programming Interface Information ........................... xi Organization of this Manual ............................... xi IBM High Level Assembler for MVS & VM & VSE Publications .......... xiv Publications . xiv Softcopy Publications . xv The High Level Assembler web site ......................... xv | Using LookAt to look up Message Explanations .................. xv Related Publications . xvi Syntax Notation . xvi Summary of Changes ................................. xix Part 1. Understanding and Using the Assembler ........................1 Chapter 1. Introduction . 5 Requirements . 5 System Requirements . 5 Machine Requirements . 5 Storage Requirements . 6 Compatibility . 7 Assembler Language Support ............................ 7 Migration Considerations . 7 Chapter 2. Using the Assembler Listing ...................... 8 High Level Assembler Option Summary ........................ 9 External Symbol Dictionary (ESD) .......................... 13 Source and Object ................................... 16 Relocation Dictionary (RLD) .............................. 23 Ordinary Symbol and Literal Cross Reference ................... 24 Unreferenced Symbols Defined in CSECTs ..................... 27 Macro and Copy Code Source Summary ...................... 27 Macro and Copy Code Cross Reference ....................... 28 DSECT Cross Reference ................................ 32 USING Map . 33 General Purpose Register Cross Reference ..................... 34 Diagnostic Cross Reference and Assembler Summary .............. 35 Chapter 3. Controlling Your Assembly with Options ............. 41 The Sources of Assembler Options .......................... 41 Precedence of Assembler Options ........................ 41 Fixed Installation Default Options ......................... 42 *PROCESS OVERRIDE Statement Options ................... 42 ASMAOPT Options . 42 Invocation Options . 42 *Process Statement Options ............................ 43 Default Options . 44 Invoking the Assembler Dynamically ....................... 44 Copyright IBM Corp. 1982, 2004 iii Contents Coding Rules . 44 Assembler Options . 45 ADATA . 45 ALIGN . 46 ASA (MVS and CMS) ................................ 46 BATCH . 47 CODEPAGE . 47 COMPAT . 48 DBCS . 49 DECK . 50 DISK (CMS) . 50 DXREF . 50 ERASE (CMS) . 51 ESD . 51 EXIT . 52 FLAG . 55 FOLD . 58 GOFF (MVS and CMS) ............................... 58 INFO . 60 LANGUAGE . 60 LIBMAC . 61 LINECOUNT . 62 LIST . 62 | MACHINE . 63 MXREF . 65 OBJECT . 66 OPTABLE . 66 PCONTROL . 68 PESTOP . 70 PRINT (CMS) . 70 PROFILE . 70 RA2 . 71 RENT . 72 RLD . 72 RXREF . 73 | SECTALGN . 73 SEG (CMS) . 73 SIZE . 74 | SUPRWARN . 76 SYSPARM . 76 TERM . 77 TEST . 78 THREAD . 78 TRANSLATE . 79 | TYPECHECK . 79 USING . 80 XOBJECT (MVS and CMS) ............................. 83 XREF . 83 Chapter 4. Providing User Exits .......................... 85 Exit Types . 85 Specifying User Exits .................................. 86 Loading User Exits ................................... 87 Calling User Exits .................................... 88 iv HLASM V1R5 Programmer’s Guide Contents Exit Parameter List ................................... 88 Request Info Pointer ................................. 90 Buffer Pointer . 97 Error Buffer Pointer ................................. 97 Exit-Specific Information Pointer .......................... 97 DCB Pointer . 97 Static Assembler Information Pointer ......................... 98 HLASM VRM . 98 PTF Level . 98 System ID . 98 | Numeric Version . 98 Error Handling . 99 Exit-Specific Information Block ............................ 99 Member Name . 101 Member Type . 101 Data Set Name .................................... 101 Volume Serial . 101 Relative Record Number .............................. 102 Absolute Record Number .............................. 103 Linecount . 103 Current Page Number ................................ 103 SOURCE Exit Processing ............................... 104 OPEN . 104 CLOSE . 104 READ . 104 PROCESS . ..
Recommended publications
  • IBM VM Recovery Manager DR for Power Systems Version 1.5: Deployment Guide Overview for IBM VM Recovery Manager DR for Power Systems
    IBM VM Recovery Manager DR for Power Systems Version 1.5 Deployment Guide IBM Note Before using this information and the product it supports, read the information in “Notices” on page 195. This edition applies to IBM® VM Recovery Manager DR for Power Systems Version 1.5 and to all subsequent releases and modifications until otherwise indicated in new editions. © Copyright International Business Machines Corporation 2020, 2021. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents About this document............................................................................................vii Highlighting.................................................................................................................................................vii Case-sensitivity in VM Recovery Manager DR............................................................................................vii ISO 9000....................................................................................................................................................viii Overview...............................................................................................................1 Concepts...............................................................................................................5 KSYS............................................................................................................................................................. 5 HMC.............................................................................................................................................................
    [Show full text]
  • High Level Assembler Macro Facility
    A++: Using the World's Most Powerful Macro Facility With High Level Assembler Parts 1 and 2 SHARE 119, Anaheim CA, Summer 2012 Presented by Tom Wasik, IBM [email protected] Contents prepared by John R. Ehrman [email protected] International Business Machines Corporation Silicon Valley Laboratory 555 Bailey Avenue San Jose, California 95141 USA Synopsis: This tutorial introduces the powerful concepts of conditional assembly supported by the High Level Assembler for z/OS, z/VM, & z/VSE, and provides examples of its use in both “open code” and in macro instructions. The examples in this document are for purposes of illustration only, and no warranty of correctness or applicability is implied or expressed. Permission is granted to SHARE Incorporated to publish this material in the proceedings of the SHARE 119. IBM retains the right to publish this material elsewhere. © Copyright IBM Corporation 1995, 2012. All rights reserved. Copyright Notices and Trademarks © Copyright IBM Corporation 1995, 2012. All rights reserved. Note to U.S. Government Users: Doc- umentation subject to restricted rights. Use, duplication, or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corp. The following terms, denoted by an asterisk (*) in this publication, are trademarks or registered trademarks of the International Business Machines Corporation in the United States and/or other countries: IBM System/370 System/390 zSeries z/OS z/VM z/VSE OS/390 DFSMS z/Architecture ESA Publications and Web Site The currently available product
    [Show full text]
  • Ibm High Level Assembler Manual Download Ibm High Level Assembler Manual
    Ibm High Level Assembler Manual Download Ibm High Level Assembler Manual This the first version of IBM Macro Assembler, released alongside the IBM PC. IBM Macro Assembler is an IBM OEM rebranded release of Microsoft Macro Assembler, and was intended only for use with the IBM PC. Installation instructions. This archive contains a 160k disk image, and is compatible with IBM PC-DOS 1.0 and later. IBM System-360 Operating System Assembler Languag§, Order Number GC28-6514. The Assembler Language manual contains the basic assembler and macro asserrbler specifications, except those unique to Assembler H. IEM System-360 Operating System Asserrbler H Language Specifications, Order Numter GC26- 3771. High Level Assembler Toolkit: HMQ4160: JMQ416A: SYS1: 5655-P97: Encryption Facility DFSMSdss Encryption: HCF773D: HCF773D: SYS1: 5655-P97: Encryption Facility Encrypt Ser: HCF7740: HCF7740: SYS1: 5655-SDK: IBM SDK for Node.Js - z-OS: HALU600: HALU600: SYS1: 5650-ZOS: ICKDSF - Device Support Facilities, Base: EDU1H01: EDU1H01: SYS1: 5650-ZOS: Environmental Record Editing and Printing: EER3500: EER3500 The next line seems to indicate to execute HLASM, the high level assembler, with the option to compile, load, and go – assemble the program and execute it. The next line indicates that the input will be from the lines of text following the JCL. The next line invokes the TITLE macro to place the title at the top of each printed page. See IBM-supplied default assembler options for a list of the changes to the IBM-supplied default assembler options from High Level Assembler Release 4. You specify the options at assembly time on: An external file (z-OS and CMS) or library member (z-VSE) The assembler programs are written in IBM Mainframe Assembler, they will compile using Assembler-H or HLASM.
    [Show full text]
  • Facility/370: Introduction
    File No. S370-20 Order No. GC20-1800=9 IDl\n \/:u+ •• ".1 I\n"n"': ..... ft IDIVI V IIlUQI .Via"'lllIlv Facility/370: Systems Introduction Release 6 PLC 4 This publication introduces VM/370, and is intended for anyone who is interested in VM/370. However, the reader should have a basic understanding of I BM data processing. VM/370 (Virtual Machine Facility/370) is a system control program (SCP) that tailors the resources and capabilities of a single System/370 computer to provide concurrent users their one unique (virtual) machine. VM/370 consists of a Control Program (CP), which manages the real computer, a Conversational Monitor System (CMS), which is a general-purpose conversational time-sharing system that executes in a virtual machine, a Remote Spooling Communications Subsystem (RSCS), which spools files to and from geographically remote locations, and a Interactive Problem Control System (I PCS), which provides problem analysis and management faci I ities. The first section of the publication is an introduction; it describes what VM/370 can do. The second, third, fourth, and fifth sections describe the Control Program, Conversational Monitor System, Remote Spooling Communications Subsystem, and Interactive Problem Control System respectively. The appendixes include information about VM/370 publication-to-audience relationship and VM/370-related publications for CMS users. , This publication is a prerequisite for the VM/370 system library. --...- --- ---.-- ------- ------ --..- --------- -~-y- Page of GC20-1800-9 As Updated Aug 1, 1979 by TNL GN25-0U89 ~b Edition (Karch 1919) This edition (GC20-1800-~ together with Technical Newsletter GN25-0489. dated August 1, 1919, applies to Release 6 PLC 4 (Program Level Change) of IBM Virtual Machine Facility/310 and to all subsequent releases until otherwise indicated in new editions or Technical Newsletters.
    [Show full text]
  • High Level Assembler for Z/OS & Z/VM & Z/VSE
    High Level Assembler for z/OS & z/VM & z/VSE 1.6 Installation and Customization Guide IBM SC26-3494-05 Note Before using this information and the product it supports, be sure to read the general information under “Notices” on page 193. This edition applies to IBM High Level Assembler for z/OS & z/VM & z/VSE, Release 6, Program Number 5696-234 and to any subsequent releases until otherwise indicated in new editions. Make sure that you are using the correct edition for the level of the product. Order publications through your IBM® representative or the IBM branch office serving your locality. IBM welcomes your comments. For information on how to send comments, see “How to send your comments to IBM” on page xx. © Copyright International Business Machines Corporation 1992, 2021. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Figures................................................................................................................. xi Tables................................................................................................................ xiii About this document.......................................................................................... xvii Brief overview of High Level Assembler...................................................................................................xvii Who should use this document................................................................................................................xvii
    [Show full text]
  • Scalability of VM Provisioning Systems
    Scalability of VM Provisioning Systems Mike Jones, Bill Arcand, Bill Bergeron, David Bestor, Chansup Byun, Lauren Milechin, Vijay Gadepally, Matt Hubbell, Jeremy Kepner, Pete Michaleas, Julie Mullen, Andy Prout, Tony Rosa, Siddharth Samsi, Charles Yee, Albert Reuther Lincoln Laboratory Supercomputing Center MIT Lincoln Laboratory Lexington, MA, USA Abstract—Virtual machines and virtualized hardware have developed a technique based on binary code substitution been around for over half a century. The commoditization of the (binary translation) that enabled the execution of privileged x86 platform and its rapidly growing hardware capabilities have (OS) instructions from virtual machines on x86 systems [16]. led to recent exponential growth in the use of virtualization both Another notable effort was the Xen project, which in 2003 used in the enterprise and high performance computing (HPC). The a jump table for choosing bare metal execution or virtual startup time of a virtualized environment is a key performance machine execution of privileged (OS) instructions [17]. Such metric for high performance computing in which the runtime of projects prompted Intel and AMD to add the VT-x [19] and any individual task is typically much shorter than the lifetime of AMD-V [18] virtualization extensions to the x86 and x86-64 a virtualized service in an enterprise context. In this paper, a instruction sets in 2006, further pushing the performance and methodology for accurately measuring the startup performance adoption of virtual machines. on an HPC system is described. The startup performance overhead of three of the most mature, widely deployed cloud Virtual machines have seen use in a variety of applications, management frameworks (OpenStack, OpenNebula, and but with the move to highly capable multicore CPUs, gigabit Eucalyptus) is measured to determine their suitability for Ethernet network cards, and VM-aware x86/x86-64 operating workloads typically seen in an HPC environment.
    [Show full text]
  • Z/OS ♦ Z Machines Hardware ♦ Numbers and Numeric Terms ♦ the Road to Z/OS ♦ Z/OS.E ♦ Z/OS Futures ♦ Language Environment ♦ Current Compilers ♦ UNIX System Services
    Mainframes The Future of Mainframes Is Now ♦ z/Architecture ♦ z/OS ♦ z Machines Hardware ♦ Numbers and Numeric Terms ♦ The Road to z/OS ♦ z/OS.e ♦ z/OS Futures ♦ Language Environment ♦ Current Compilers ♦ UNIX System Services by Steve Comstock The Trainer’s Friend, Inc. http://www.trainersfriend.com 800-993-8716 [email protected] Copyright © 2002 by Steven H. Comstock 1 Mainframes z/Architecture z/Architecture ❐ The IBM 64-bit mainframe has been named "z/Architecture" to contrast it to earlier mainframe hardware architectures ♦ S/360 ♦ S/370 ♦ 370-XA ♦ ESA/370 ♦ ESA/390 ❐ Although there is a clear continuity, z/Architecture also brings significant changes... ♦ 64-bit General Purpose Registers - so 64-bit integers and 64-bit addresses ♦ 64-bit Control Registers ♦ 128-bit PSW ♦ Tri-modal addressing (24-bit, 31-bit, 64-bit) ♦ Over 140 new instructions, including instructions to work with ASCII and UNICODE strings Copyright © 2002 by Steven H. Comstock 2 z/Architecture z/OS ❐ Although several operating systems can run on z/Architecture machines, z/OS is the premier, target OS ❐ z/OS is the successor to OS/390 ♦ The last release of OS/390 was V2R10, available 9/2000 ♦ The first release of z/OS was V1R1, available 3/2001 ❐ z/OS can also run on G5/G6 and MP3000 series machines ♦ But only in 31-bit or 24-bit mode ❐ Note these terms: ♦ The Line - the 16MiB address limit of MVS ♦ The Bar - the 2GiB limit of OS/390 ❐ For some perspective, realize that 16EiB is... ♦ 8 billion times 2GiB ♦ 1 trillion times 16MiB ❐ The current release of z/OS is V1R4; V1R5 is scheduled for 1Q2004 Copyright © 2002 by Steven H.
    [Show full text]
  • Cisco UCS C240 M4 SFF Rack Server Spec Sheet
    This Product has been discontinued Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV E.20 MARCH 23, 2021 WWW.CISCO.COM CONTENTS OVERVIEW . 5 DETAILED VIEWS . 6 Chassis Front View . .6 Chassis Rear View . .9 BASE SERVER STANDARD CAPABILITIES and FEATURES . 11 CONFIGURING the SERVER . 15 STEP 1 VERIFY SERVER SKU . 16 STEP 2 SELECT RISER CARDS (OPTIONAL) . 17 STEP 3 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . 18 STEP 4 SELECT CPU(s) . 19 STEP 5 SELECT MEMORY . 21 STEP 6 SELECT RAID CONTROLLERS . 27 RAID Controller Options (internal HDD/SSD support) . 27 Embedded Software RAID . 27 Cisco 12G SAS Modular RAID Controller . 27 SAS HBA (internal HDD/SSD/JBOD support) . 27 SAS HBA (external JBOD support) . 27 RAID Volumes and Groups . 28 STEP 7 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . 39 STEP 8 SELECT SED HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . 45 STEP 9 SELECT PCIe OPTION CARD(s) . 48 STEP 10 ORDER OPTIONAL NETWORK CARD ACCESSORIES . 53 STEP 11 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL) . 58 STEP 12 ORDER POWER SUPPLY . 61 STEP 13 SELECT AC POWER CORD(s) . 62 STEP 14 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 65 STEP 15 SELECT NIC MODE (OPTIONAL) . 66 STEP 16 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . 67 STEP 17 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . 69 STEP 18 ORDER OPTIONAL USB 3.0 DRIVE .
    [Show full text]
  • IBM Virtual Machine Facility/370 : Systems Introduction
    GC20-1800-0 IBM Virtual Machine Facility/370 : Systems Introduction The IBM Virtual Machine Facility/370 (VM/370) is a System Control Program (SCP) that has been designed specifically for the IBM System/370. VM/370 manages the IBM System/370 in such a way that mUltiple remote terminal users appear to have a dedicated computing system at their disposal. Within this "virtual machine" the user may run the operaHng system of his choice, subject to the restrictions noted in "Appendix C: VM/370 Restrictions" of this manual. The design of VM/370 is based on the IBM Control Program-67/Cam­ bridge Monitor System (CP-67/CMS) which is executed on an IBM System/360 Model 67. The Conversational Monitor System (CMS) is the major subsystem ofVM/370. CMS provides problem solving and program development services to the user, as well as supporting facilities for a remote user who chooses to run some other operating system in his virtual machine. This manual provides introductory information about the facilities provided by VM/370, and defines the min­ imum equipment configuration necessary for execution. Preface This manual provides introductory information on the IBM Virtual Machine Facility/370 (VM/370) and its associated subsystem, the Conversational Monitor Sys­ tem (CMS), as well as an overview of the purpose and functions of VM/370. It is assumed that the user has a prior knowledge of virtual storage concepts as implemented on the IBM System/370 via dynamic address translation. The reader is referred to Part I of the student text publication Introduction to Virtual Storage in System/370, Order No.
    [Show full text]
  • Microkernel Vs
    1 VIRTUALIZATION: IBM VM/370 AND XEN CS6410 Hakim Weatherspoon IBM VM/370 Robert Jay Creasy (1939-2005) Project leader of the first full virtualization hypervisor: IBM CP-40, a core component in the VM system The first VM system: VM/370 Virtual Machine: Origin 3 IBM CP/CMS CP-40 CP-67 VM/370 Why Virtualize 4 Underutilized machines Easier to debug and monitor OS Portability Isolation The cloud (e.g. Amazon EC2, Google Compute Engine, Microsoft Azure) IBM VM/370 Specialized Conversation Mainstream VM al Monitor OS (MVS, Another Virtual subsystem System DOS/VSE copy of VM machines (RSCS, RACF, (CMS) etc.) GCS) Hypervisor Control Program (CP) Hardware System/370 IBM VM/370 Technology: trap-and-emulate Problem Application Privileged Kernel Trap Emulate CP Classic Virtual Machine Monitor (VMM) 7 Virtualization: rejuvenation 1960’s: first track of virtualization Time and resource sharing on expensive mainframes IBM VM/370 Late 1970’s and early 1980’s: became unpopular Cheap hardware and multiprocessing OS Late 1990’s: became popular again Wide variety of OS and hardware configurations VMWare Since 2000: hot and important Cloud computing Docker containers Full Virtualization 9 Complete simulation of underlying hardware Unmodified guest OS Trap and simulate privileged instruction Was not supported by x86 (Not true anymore, Intel VT-x) Guest OS can’t see real resources Paravirtualization 10 Similar but not identical to hardware Modifications to guest OS Hypercall Guest OS registers handlers Improved performance VMware ESX Server 11 Full virtualization Dynamically rewrite privileged instructions Ballooning Content-based page sharing Denali 12 Paravirtualization 1000s of VMs Security & performance isolation Did not support mainstream OSes VM uses single-user single address space 13 Xen and the Art of Virtualization Xen 14 University of Cambridge, MS Research Cambridge XenSource, Inc.
    [Show full text]
  • IIP (System Z9 Integrated Information Processor) Computer CEC (Central Electronics Complex) Server
    IBM System z z/VM Basics Arwed Tschoeke Systems Architect [email protected] © 2009 IBM Corporation © 2008 IBM Corporation Introduction We'll explain basic concepts of System z: – Terminology – Processors – Memory – I/O – Networking We'll see that z/VM virtualizes a System z machine: – Virtual processors – Virtual memory – … and so on Where appropriate, we'll compare or contrast: – PR/SM or LPAR – z/OS – Linux 2 z/VM: The Very Basics z/VM: The Very Basics 1 IBM System z © 2008 IBM Corporation System z Parts Nomenclature x86, UNIX, etc. System z Memory Storage (though we are moving toward "memory") Disk, Storage DASD – Direct Access Storage Device Processor Processor, Engine, PU (processing unit) IOP (I/O processor) CPU (central processing unit) CP (central processor) SAP (system assist processor) Specialty engines –IFL (Integrated Facility for Linux) –zAAP (System z Application Assist Processor) –zIIP (System z9 Integrated Information Processor) Computer CEC (central electronics complex) Server 3 z/VM: The Very Basics © 2008 IBM Corporation IBM System z Virtualization Genetics Over 40 years of continuous innovation in virtualization – Refined to support modern business requirements System z10 . – Exploit hardware technology for economical growth , .. ity System z9 z/VM V5 bil – LPAR, Integrated Facility for Linux, HiperSockets xi 64-Bit Fle – System z Application Assist Processors s, zSeries es VM/ESA Virtual Switch – System z Information Integration stn 9672 bu ESA Guest LANs Set Observer Ro Processors y, 9x21 ilit VM/XA Virtual Machine
    [Show full text]
  • IBM Powervm Virtualization Introduction and Configuration
    Front cover IBM PowerVM Virtualization Introduction and Configuration Understand PowerVM features and capabilities Plan, implement, and set up PowerVM virtualization Updated to include new POWER7 technologies Mel Cordero Lúcio Correia Hai Lin Vamshikrishna Thatikonda Rodrigo Xavier ibm.com/redbooks International Technical Support Organization IBM PowerVM Virtualization Introduction and Configuration June 2013 SG24-7940-05 Note: Before using this information and the product it supports, read the information in “Notices” on page xxi. Sixth Edition (June 2013) This edition applies to: Version 7, Release 1 of AIX Version 7, Release 1 of IBM i Version 2, Release 2, Modification 2, Fixpack 26 of the Virtual I/O Server Version 7, Release 7, Modification 6 of the HMC Version AL730, release 95 of the POWER7 System Firmware Version AL740, release 95 of the POWER7 System Firmware © Copyright International Business Machines Corporation 2004, 2013. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Figures . xi Tables . xix Notices . xxi Trademarks . xxii Preface . xxiii Authors . xxiii Now you can become a published author, too! . xxvi Comments welcome. xxvi Stay connected to IBM Redbooks . .xxvii Summary of changes . xxix June 2013, Sixth Edition. xxix Part 1. Overview . 1 Chapter 1. PowerVM technologies. 3 1.1 The value of PowerVM . 4 1.2 What is PowerVM . 4 1.2.1 New PowerVM features . 6 1.2.2 PowerVM editions . 7 1.2.3 Activating the PowerVM feature . 12 1.3 The POWER Hypervisor . 15 1.4 Logical partitioning technologies . 17 1.4.1 Dedicated LPAR .
    [Show full text]