EcoTouch ® PINK® FIBERGLAS™ Insulation with PureFiber® Technology

Product Data Sheet

PROPINK® EcoTouch ® Insulation Product Data Width Length Thickness R-Value1 Metal Frame 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 31/2" (89mm) 11 Construction 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 31/2" (89mm) 13 16" (406mm) 24" (609mm) 96" (2,438mm) 31/2" (89mm) 15 16" (406mm) 24" (609mm) 96" (2,438mm) 51/2" (139mm) 21 Frame 15" (381mm) 23" (584mm) 48" (1,219mm) 93" (2,362mm) 31/2" (89mm) 11 Construction 15" (381mm) 23" (584mm) 48" (1,219mm) 93" (2,362mm) 31/2" (89mm) 13 Walls 15" (381mm) 23" (584mm) 93" (2,362mm) 31/2" (89mm) 15 15" (381mm) 191/4" 23" (584mm) 48" (1,219mm) 93" (2,362mm) 61/4" (159mm) 19 15" (381mm) 23" (584mm) 93" (2,362mm) 51/2" (139mm) 20 15" (381mm) 23" (584mm) 93" (2,362mm) 51/2" (139mm) 21 15" (381mm) 23" (584mm) 105" (2,667mm) 51/2" (139mm) 21 23" (381mm) 23" (584mm) 93" (2,362mm) 51/2" (139mm) 21 Floor/Ceiling 15" (381mm) 191/4" 23" (584mm) 48" (1,219mm) 93" (2,362mm) 61/4" (159mm) 19 15" (381mm) 23" (584mm) 48" (1,219mm) 63/4" (171mm) 22 15" (381mm) 23" (584mm) 48" (1,219mm) 8" (203mm) 25 151/2" (394mm) 233/4" (603mm) 48" (1,219mm) 81/4" (209mm) 30 16" (406mm) 191/4" 24" (609mm) 48" (1,219mm) 91/2" (241mm) 30 151/2" (394mm) 233/4" (603mm) 48" (1,219mm) 101/4" (260mm) 38 16" (406mm) 24" (609mm) 48" (1,219mm) 12" (305mm) 38 16" (406mm) 24" (609mm) 48" (1,219mm) 14" (356mm) 49

specifications with ease. The With less dust than other fiberglass R30C and R38C provide excellent insulation products, EcoTouch® ® thermal performance in the Insulation has excellent stiffness and limited space of cathedral ceilings. recovery characteristics.2 Effective Acoustical Control Designed with the EcoTouch ® Insulation enhances Environment in Mind interior noise control by improving EcoTouch ® Insulation includes a Description the Sound Transmission Class minimum of 50% total recycled ™ EcoTouch ® (STC) of walls and floor/ceiling content—the highest certified Insulation with PureFiber® assemblies. recycled content available in the 3 ® Technology is flexible insulation fiberglass . EcoTouch Long Term Performance Insulation is GREENGUARD Gold made in R-values from 11 EcoTouch ® Insulation is to 49. EcoTouch® Insulation is Certified and is verified to be dimensionally stable and will not formaldehyde free.4 available plain, or faced with either slump within the wall cavity. Due a kraft or foil vapor retarder. The ® to its inorganic , EcoTouch SpaceSaver Packaging product is manufactured in 1 Insulation will not rot or mildew ® thicknesses from 31/2" to 14". EcoTouch Insulation is and is noncorrosive to , compression packaged in exclusive Uses copper, and aluminum. SpaceSaver packaging from EcoTouch ® Insulation can be used Easy Installation Owens Corning Insulating in a wide range of exterior wall EcoTouch ® Insulation is easy to Systems. SpaceSaver packaging and roof/ceiling applications. The handle and install. Sized for reduces freight and speeds job site product can be installed in wood installation in either wood or handling/installation. or metal framing cavities, or can metal stud construction, be installed between furring strips. EcoTouch ® Insulation can either be Design Considerations friction-fit or stapled into place. Kraft and standard foil facings on Features and Benefits Trimming and fabrication can be this insulation will burn and must Excellent Thermal Control done with an ordinary utility knife not be left exposed. Install facings With the range of R-values and and is easily installed into odd- in substantial contact with the thicknesses available, EcoTouch® shaped cavities and small spaces. finish material. Protect from open Insulation can meet most thermal flame or other heat source. EcoTouch ® PINK® FIBERGLAS™ Insulation with PureFiber® Technology

Product Data Sheet

Buildings utilizing curtainwall Technical Data construction may be required to be equipped with a sprinkler Property (Unit) Value Test system to provide adequate fire Dimensional Stability (shrinkage) <0.1% ASTM C167 protection. Check local building Surface Burning Characteristics ASTM E84 (flame spread / smoke developed) codes for specific requirements. Unfaced 25 / 50 Kraft faced NR / NR Foil faced 75 / 150 Commercial roof/ceiling thermal Poly / FSK / PSK faced" 25 / 50 applications require that the Critical Radiant Flux (W/cm2) ASTM E970 building envelope block the all facings >0.12 movement of air from the outdoor Water Vapor Permeance (perms) ASTM E96 Kraft faced 1.0 environment to the conditioned Foil faced 0.5 Poly faced 0.7 space. Neither the insulation nor FSK & PSK faced 0.02 its facing should be relied upon to Water Vapor Sorption (by weight) <5% ASTM C1104 provide an air barrier. Failure to Odor Emission Pass ASTM C1304 provide an adequate air barrier Resistance Pass ASTM C665, part 13.8 could lead to loss of thermal Fungi resistance Pass ASTM C1338 control, discomfort of the building occupants and frozen pipes. Classifications When insulation is added to the EcoTouch® Product ICC Building Construction ASTM C665 inside perimeter of a structure, Unfaced all types Type I the area outside the insulation Kraft faced Type III, IV, V Type II, Class C, Cat. 1 becomes exposed to greater Foil faced Type III, IV, V Type III, Class C, Cat. 1 temperature extremes. Check for piping which should be protected for such use. This is a requirement The thermal resistance values for against freezing. of the National Electrical Code. EcoTouch ® Insulation were tested The need for and placement of a in accordance with ASTM C518; Due to the potential for skin R-value for insulation only. vapor retarder in commercial irritation, EcoTouch® Unfaced construction depends on many Insulation should not be used for The surface burning characteristics factors. The architect or specifier exposed applications where it will of EcoTouch® Insulation were should evaluate the requirements be subject to human contact. derived from products tested in of each project. If a vapor accordance with ASTM E84. This retarder is specified, maintaining Applicable Standards standard is used solely to measure the facing integrity may be EcoTouch ® Unfaced Insulation is and describe properties of important for effective moisture/ manufactured in compliance with products in response to heat and humidity control. Repair any ASTM Standard Specification flame under controlled laboratory punctures or tears in the facing by C665 and is classified conditions, and should not be used taping. Follow the tape noncombustible per ASTM E136. to describe or approve the fire manufacturer’s application EcoTouch ® Kraft-faced Insulation hazard of materials under actual recommendations. is manufactured in compliance fire conditions. However, the with ASTM C665, Type II, Class results of these tests may be used Insulation installed too close to C. EcoTouch® Foil-faced Insulation as elements of a fire risk light fixtures may affect the is manufactured in compliance assessment that takes into account luminaire’s performance. Do not with ASTM C665, Type III, Class all of the factors pertinent to an install insulation on top of or B and C. Federal Specification assessment of the fire hazard of a within 3" of recessed light fixtures HH-I-521F has been canceled and particular end use. Values are unless the fixtures are approved is replaced by ASTM C665. reported to the nearest five rating. EcoTouch ® PINK® FIBERGLAS™ Insulation with PureFiber® Technology

Product Data Sheet

Figure 1 The vapor retarder permeance of used, the attachment flanges may the kraft and foil facings on be taped to the face of the metal EcoTouch ® Insulation were stud prior to applying the interior developed from tests conducted finish. Wire or metal straps should in accordance with ASTM E96, also be used to hold the product desiccant method. in place in applications without a 1" Ventilation Passageway cover material or where the stud Installation depth is larger than the insulation Between Wood Studs/Rafters thickness. EcoTouch ® Insulation fits between studs. If required, the flanges can Furring Strips ® be stapled to either the face or EcoTouch Insulation can be the side of the stud every 8–12" to applied between furring strips, hat prevent gaping or “fishmouthing” channels, or Z-shaped furring in of the vapor retarder. areas where a finish surface will be installed. Contact the furring Figure 2 EcoTouch ® Unfaced insulation can strip manufacturer for appropriate be friction-fit between studs after fastening system. the cover material has been ™ installed on one side of the cavity. Caution: FIBERGLAS insulation Use wire or metal straps to hold may cause temporary irritation insulation in place in applications to the skin, eyes and respiratory without a cover material, or tract. Avoid contact with eyes where the insulation does not fill and skin, wear loose-fitting, the depth of the cavity. long-sleeved clothing, gloves and eye protection when handling Cathedral ceiling products (R30C and applying the material. Wash and R38C) are intended to be with soap and cold water after friction-fit between rafters. handling. Wash work clothes Cathedral ceiling insulation should separately and wipe out washer. be installed to provide a minimum 1" ventilation passageway between the roof deck and insulation. (See Figure 1) It is recommended to use a vent baffle to assure proper clearance. Between Metal Studs EcoTouch ® Insulation can be friction-fit in place until the interior finish is applied. Insulation should fill the cavity and the wall should eventually be closed on both sides. (See Figure 2) In areas where it will be applied in heights over 8', use wire or metal straps to hold the product in place until the interior finish is applied. When faced insulation is EcoTouch ® PINK® FIBERGLAS™ Insulation with PureFiber® Technology

Product Data Sheet Notes 1. As manufactured, FIBERGLAS™ insulation is resistant to mold growth. However, mold growth can occur on building materials, including insulation, when it becomes contaminated with organic material and when water is present. To avoid mold growth on FIBERGLAS™ insulation, remove any water that has accumulated and correct or repair the source of the water as soon as possible. Insulation that has become wet should be inspected for evidence of residual moisture and contamination, and any insulation that is contaminated should be promptly removed and replaced. 2. According to 2010 clinical trial conducted in Toronto, Canada by Ducker Worldwide on behalf of Owens Corning Insulation Systems, LLC. 3. Certified by Scientific Certifications Systems to have a minimum of 50% recycled content, with at least 30% post-consumer recycled and the balance of pre-consumer recycled glass content. 4. Owens Corning™ EcoTouch ® Unfaced FIBERGLAS™ insulation is verified to be formaldehyde free by the GREENGUARD Environmental Institute.

GREENGUARD Indoor Air Quality and GREENGUARD Gold Certified Products applies to EcoTouch® Unfaced Batts, EcoTouch ® Faced Batts and Unbonded Loosefill Insulation. GREENGUARD Formaldehyde Free applies to EcoTouch® Unfaced Batts and Unbonded Loosefill Insulation.

GREENGUARD Gold Certified Products applies to Flame Spread 25 FSK Faced; Flame Spread 25 Extended Flanges PSK Faced; Sound Attenuation Batt Insulation; SCS 50% recycled content applies to EcoTouch® Unfaced Batts and Sonobatts® Insulation Unfaced; Rolls, EcoTouch® Faced Batts and Rolls, Loosefill Insulation, Metal Sonobatts® Insulation Kraft-Faced and Building Insulation products and Flexible Air Handling products. Metal Building Insulation.

Applies to EcoTouch ® Unfaced Insulation

Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or OWENS CORNING INSULATING SYSTEMS, LLC liable for the accuracy or reliability of data associated ONE OWENS CORNING PARKWAY with particular uses of any product described herein. TOLEDO, OHIO, USA 43659 Nothing contained in this bulletin shall be considered a 1-800-GET-PINK® recommendation. www.owenscorning.com GREENGUARD Certified products are certified to Pub. No. 10013811-D. Printed in U.S.A. October 2014. THE PINK PANTHER ™ GREENGUARD standards for low chemical emissions & ©1964–2014 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The into indoor air during product usage. For more color PINK is a registered trademark of Owens Corning. © 2014 Owens Corning. information, visit ul.com/gg. All Rights Reserved.