GB4548 RACECOURSE CREEK, ASCOT 1% AEP Flood Containment Upgrades June 2020
Total Page:16
File Type:pdf, Size:1020Kb
GB4548 RACECOURSE CREEK, ASCOT 1% AEP Flood containment upgrades June 2020 DOCUMENT CONTROL No. xx/xx/xx xx/xx/xx DESC. SHEET SHEET 13/8/2020 DRAFT TENDER CONSTRUCTION REVISION REVISION REVISION 1 COVER SHEET A 2 GENERAL NOTES A 3 PLAN VIEW A 4 PLAN VIEW A 5 PLAN VIEW A 7 PLAN VIEW A 8 LONG SECTIONS A 9 LONG SECTIONS A 10 LONG SECTIONS A 11 CROSS SECTIONS A 12 CROSS SECTIONS A 13 CROSS SECTIONS A 14 CROSS SECTIONS A 15 CROSS SECTIONS A LOCALITY PLAN PROJECT EXTENTS PROJECT PLANNING REQUIREMENTS AMENDMENTS Survey H. Whytock June 19 Item Required Comments Contractor Revision Description Approved by Date CITY OF GREATER BENDIGO Design N. Sartori Oct 19 PRELIMINARY DESIGN Vegetation Yes Underway - - - - Checked A.Smith Nov 19 RRV Yes - RACECOURSE CREEK Approved by B.Martini Jan 20 DRAFT 1 CMA Yes Underway Scale: - Revision : A Planning Permit Yes Underway ASCOT Original sheet size: A3 File : Land Acquisition Underway Yes FLOOD CONTAINMENT WORKS Sheet: Reference: CHMP Yes - Plot Date: 17/04/2020 1 OF 10 VicTrack underway COVER PAGE GB4548 Other Yes Plotted By: NATHAN SARTORI DAM WALL / EARTHEN EMBANKMENT NOTES DETAIL: Earthen Embankmenrt 1. The existing surface under the wall structure shall be excavated to a depth of 150mm prior to construction. Unless noted otherwise, the spoil shall be stored onsite, and spread evenly over the finished wall construction. 100mm depth CL3 FCR 2. Fill to be used in construction of the wall shall be approved by the superintendents representative prior to importing to 3.00 on top of wall as site, and shall have the following properties: shown. Compact to 98%SMDD Generally batter at 1:4. - A consistent mix of sand, gravel and clay Construct earthen embankment as Some areas battered at - >30% clay content per notes this page. Finish with 1:10. See plans - Mix is to be non dispersive minimum 50mm depth sandy loam Batter at 1 in 4 - Free of any organic material or contaminants topsoil and grass seed 3. Unless noted otherwise, the wall construction shall be undertaken as follows: - Fill material shall be within -1% to +3% of Optimum Moisture Content during compaction Varies - Fill shall be placed and compacted in 200mm layers to 98% Standard Maximum Dry Density - Unless approved otherwise by the Superintendents representative, a vibrating pad foot roller shall be used to undertake compaction and bonding between fill layers - In situ testing of the walls compaction and moisture content shall be undertaken as outlined for Type C material in Vicroads earthworks Specification 204: section 204.14 (c), and table 204.142. Typical Section 4. The Contractor is responsible for ensuring that all imported fill material, including topsoil, satisfies the description for clean fill material in EPA bulletin publication No. 448 (Sep 95) and subsequent revisions. The Contractor shall provide verification including test certificates to the Superintendent's Representative. 5. Any pipe intrusions through the wall are to be rubber ring jointed DETAIL: Retaining wall fence Concrete tilt up panels act as retaining wall for 1%AEP flow. (yet to be designed) Varies section on long depending Base of concrete panel buried 0.1m below adjacent existing surface 0.15 Tilt up fence panel posts 0.10 and footings yet to be Typical Section Typical Elevation designed. (May be more cost effective to lengthen the concrete tilt panels to go further into the ground) AMENDMENTS Survey H. Whytock June 19 Revision Description Approved by Date CITY OF GREATER BENDIGO Design N. Sartori Oct 19 PRELIMINARY DESIGN - - - - Checked A.Smith Nov 19 RACECOURSE CREEK Approved by B.Martini Jan 20 DRAFT 1 ASCOT Scale: - Revision : A Original sheet size: A3 File : FLOOD CONTAINMENT WORKS Sheet: Reference: Plot Date: 17/04/2020 GENERAL NOTES 2 OF 10 GB4548 Plotted By: NATHAN SARTORI CH 200.00 BENDIGO - EPSOM RAIL LINE Proposed levy bank matches top of rail embankment CH 280.00 at 192.200. 1% AEP water level does not overtop rail embankment RAIL RESERVE BOUNDARY CH 260.00 CH 180.00 CH 240.00 CH 140.00 CH 160.00 CH 220.00 CH 120.00 Top of bank is proposed to be 500mm higher than tee, and CH 200.00 800mm higher than adjacent fairway. Bank BENDIGO GOLF CLUB batters are at 1:4 CH 100.00 ROPER TERRACE CH 180.00 Alignment: East 1 CH 80.00 CH 160.00 Alignment: West 1 BENDIGO - EPSOM RAIL LINE CH 60.00 CH 140.00 Discussion required around access to existing clear span CH 40.00 bridge CH 120.00 CH 0.00 CH CH 100.00 CH 20.00 CH 20.00 CH CH 80.00 CH 40.00 CH CH 60.00 CH 0.00 Batters graded at 10% between CH 0 - 100 Discussion required around access to existing clear span bridge. Rail reserve boundary BENDIGO RACECOURSE (50m wide reserve) Rail reserve boundary (50m wide reserve) AMENDMENTS Survey H. Whytock June 19 Revision Description Approved by Date CITY OF GREATER BENDIGO Design N. Sartori Oct 19 PRELIMINARY DESIGN Raise existing endwall FCR top of Earthen Embankment - - - - Checked A.Smith Nov 19 RACECOURSE CREEK Approved by B.Martini Jan 20 DRAFT 1 Grassed batters of Earthen Embankment Tree to be assessed and removed (unconfirmed) ASCOT Scale: 1:1000 (A3) Revision : A Original sheet size: A3 File : Concrete retaining wall FLOOD CONTAINMENT WORKS Sheet: Reference: Plot Date: 17/04/2020 PLAN VIEW 3 OF 10 GB4548 Plotted By: NATHAN SARTORI CH 80.00 TAYLOR STREET CH 100.00 CH 60.00 Alignment: East 2 CH 85.83 CH 40.00 CH 80.00 Alignment: West 2 CH 60.00 CH 20.00 CH 40.00 CH 0.00 Rail reserve boundary (50m CH 0.00 wide reserve) CH 20.00 CH 424.99 Raise concrete endwall to approx 1.5m higher than road CH 420.00 surface (to 191.95 AHD) and install vehicle guard fence CH 2.80 CHRYSLER DRIVE CH 0.00 Raise concrete endwall to CH 298.78 approx 0.7m higher than road surface (to 191.20 AHD) and install vehicle guard fence CH 0.00 CH 400.00 Alignment: East 1 CH 380.00 CH 280.00 Rail reserve boundary (50m wide reserve) CH 360.00 CH 260.00 ROPER TERRACE CH 340.00 TAYLOR STREET CH 240.00 CHRYSLER DRIVE CH 320.00 Power infrastructure at CH230 and CH CH 220.00 245 will required retaining wall to contain batter fill ROAD RESERVE RAIL RESERVE BOUNDARY CH 300.00 CH 200.00 BENDIGO - EPSOM RAIL LINE CH 280.00 Alignment: West 1 RAIL RESERVE BOUNDARY CH 260.00 CH 180.00 CH 240.00 CH 140.00 CH 160.00 CH 220.00 CH 120.00 CH 200.00 AMENDMENTS Survey H. Whytock June 19 Revision Description Approved by Date CITY OF GREATER BENDIGO Design N. Sartori Oct 19 PRELIMINARY DESIGN Raise existing endwall FCR top of Earthen Embankment Nov 19 - - - ROPER -TERRACE Checked A.Smith RACECOURSE CREEK Approved by B.Martini Jan 20 DRAFT 1 Grassed batters of Earthen Embankment Tree to be assessed and removed (unconfirmed) ASCOT Scale: 1:1000 (A3) Revision : A Original sheet size: A3 File : Concrete retaining wall FLOOD CONTAINMENT WORKS Sheet: Reference: Plot Date: 17/04/2020 PLAN VIEW 4 OF 10 GB4548 Plotted By: NATHAN SARTORI CH 80.00 CH 80.00 CH 60.00 Alignment: East 3 Alignment: West 3 CH 60.00 CH 40.00 CH 40.00 CH 20.00 CH 0.00 Non standard road width CH 20.00 Existing endwalls require raising on both sides by approx 1.0m to retain flows in current state. Recommend replacement of MIDLAND HIGHWAY GOLF COURSE ROAD structure with crown units, new endwalls and a standard width road. Option to also raise rd and install GF if required. Detailed design required CH 0.00 CH 224.33 CH 220.00 CH 224.33 CH 199.30 CH 199.30 GOLF COURSE ROAD CH 217.09 CH 180.00 CH 200.00 CH 173.97 CH 160.00 CHRYSLER DRIVE CH 180.00 CH 152.89 CH 140.00 CH 164.47 CH 160.00 CH 120.00 Alignment: East 2 CH 140.00 CH 100.00 CH 101.20 Alignment: West 2 CH 120.00 CH 80.00 TAYLOR STREET CH 100.00 CH 60.00 CH 85.83 CH 40.00 CH 80.00 AMENDMENTS Survey H. Whytock June 19 Revision Description Approved by Date CITY OF GREATER BENDIGO Design N. Sartori Oct 19 PRELIMINARY DESIGN Raise existing endwall FCR top of Earthen Embankment - - - - Checked A.Smith Nov 19 RACECOURSE CREEK Approved by B.Martini Jan 20 DRAFT 1 Grassed batters of Earthen Embankment Tree to be assessed and removed (unconfirmed) ASCOT Scale: 1:1000 (A3) Revision : A Original sheet size: A3 File : Concrete retaining wall FLOOD CONTAINMENT WORKS Sheet: Reference: Plot Date: 17/04/2020 PLAN VIEW 5 OF 10 GB4548 Plotted By: NATHAN SARTORI CH 320.00 LANGLEY DRIVE CH 320.00 CH 300.00 CH 300.00 Construct earthen embankment close to road (batter 1:10) Construct retaining wall and fence across Road reserve MIDLAND HIGHWAY CH 280.00 CH 280.00 CH 260.00 WAVERLEY ROAD CH 260.00 CH 240.00 Alignment: West 3 CH 240.00 CH 220.00 CH 220.00 CH 200.00 CH 200.00 Alignment: East 3 CH 180.00 CH 180.00 CH 160.00 CH 160.00 CH 140.00 CH 140.00 CH 120.00 CH 120.00 CH 100.00 CH 100.00 CH 80.00 CH 80.00 CH 60.00 AMENDMENTS Survey H.